Energy Metering IC with On-Chip  
Fault and Missing Neutral Detection  
ADE7761  
FEATURES  
GENERAL DESCRIPTION  
High accuracy active energy measurement IC, supports  
IEC 687/61036  
Less than 0.1% error over a dynamic range of 500 to 1  
Supplies active power on the frequency outputs F1 and F2  
High frequency output CF is intended for calibration and  
supplies instantaneous active power  
Continuous monitoring of the phase and neutral current  
allows fault detection in 2-wire distribution systems  
Current channels input level best suited for current  
transformer sensors  
Uses the larger of the two currents (phase or neutral) to  
bill—even during a fault condition  
Continuous monitoring of the voltage and current inputs  
allows missing neutral detection  
Uses one current input (phase or neutral) to bill when  
missing neutral is detected  
The ADE7761 is a high accuracy, fault tolerant, electrical energy  
measurement IC intended for use with 2-wire distribution  
systems. The part specifications surpass the accuracy require-  
ments as quoted in the IEC61036 standard.  
The only analog circuitry used on the ADE7761 is in the ADCs  
and reference circuit. All other signal processing (such as multi-  
plication and filtering) is carried out in the digital domain. This  
approach provides superior stability and accuracy over extremes  
in environmental conditions and over time.  
The ADE7761 incorporates a fault detection scheme similar to  
the ADE7751 by continuously monitoring both the phase and  
neutral currents. A fault is indicated when these currents differ  
by more than 6.25%.  
Two logic outputs (FAULT and REVP) can be used to indicate  
a potential miswiring, fault, or missing neutral condition  
(continued on Page 3)  
Direct drive for electromechanical counters and 2-phase  
stepper motors (F1 and F2)  
Proprietary ADCs and DSP provide high accuracy over large  
variations in environmental conditions and time  
Reference 2.5 V 8% (drift 30 ppm/°C typical) with external  
overdrive capability  
Single 5 V supply, low power  
FUNCTIONAL BLOCK DIAGRAM  
V
AGND  
8
FAULT  
15  
DD  
1
POWER  
SUPPLY MONITOR  
V
V
V
2
4
1A  
1N  
ADE7761  
SIGNAL PROCESSING  
BLOCK  
ADC  
ADC  
ADC  
ADC  
HPF  
A>B  
LPF  
B>A  
A<>B  
3
7
ZERO CROSSING  
DETECTION  
1B  
MISSING NEUTRAL  
GAIN ADJUST  
MISCAL  
6
5
V
V
2P  
MISSING NEUTRAL  
DETECTION  
2N  
4k  
2.5V  
REFERENCE  
INTERNAL  
OSCILLATOR  
DIGITAL-TO-FREQUENCY CONVERTER  
9
14  
17  
10  
11  
12  
16  
18  
19  
20  
REF  
RCLKIN  
DGND  
SCF S1 S0 REVP CF F2 F1  
IN/OUT  
Figure 1.  
Rev. A  
.
Information furnished by Analog Devices is believed to be accurate and reliable.  
However, no responsibility is assumed by Analog Devices for its use, nor for any  
infringements of patents or other rights of third parties that may result from its use.  
Specifications subject to change without notice. No license is granted by implication  
or otherwise under any patent or patent rights of Analog Devices. Trademarks and  
registered trademarks are the property of their respective owners.  
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.  
Tel: 781.329.4700  
Fax: 781.326.8703  
www.analog.com  
© 2004 Analog Devices, Inc. All rights reserved.  
ADE7761  
TABLE OF CONTENTS  
General Description......................................................................... 3  
Active Power Calculation.......................................................... 15  
Digital-to-Frequency Conversion............................................ 18  
Transfer Function....................................................................... 18  
Fault Detection ........................................................................... 19  
Missing Neutral Mode............................................................... 20  
Applications..................................................................................... 23  
Interfacing to a Microcontroller for Energy Measurement.. 23  
Selecting a Frequency for an Energy Meter Application....... 23  
Negative Power Information..................................................... 24  
Outline Dimensions....................................................................... 25  
Ordering Guide .......................................................................... 25  
Disclaimer........................................................................................ 26  
Specifications..................................................................................... 4  
Timing Characteristics..................................................................... 6  
Absolute Maximum Ratings............................................................ 7  
ESD Caution.................................................................................. 7  
Terminology ...................................................................................... 8  
Pin Configuration and Function Descriptions............................. 9  
Typical Performance Characteristics ........................................... 11  
Operation......................................................................................... 13  
Power Supply Monitor ............................................................... 13  
Analog Inputs.............................................................................. 13  
Internal Oscillator ...................................................................... 14  
Analog-to-Digital Conversion.................................................. 14  
REVISION HISTORY  
2/04—Changed from Rev. 0 to Rev. A.  
Changes to Ordering Guide .......................................................... 25  
1/04—Revision 0: Initial Version  
Rev. A | Page 2 of 28  
ADE7761  
GENERAL DESCRIPTION  
(continued from Page 1)  
The ADE7761 incorporates a missing neutral detection scheme  
by continuously monitoring the input voltage. When a missing  
neutral condition is detected—no voltage input—the ADE7761  
continues billing based on the active current signal (see the  
Missing Neutral Mode section). The missing neutral condition  
is indicated when the FAULT pin goes high.  
The ADE7761 includes a power supply monitoring circuit on  
the VDD supply pin. Internal phase matching circuitry ensures  
that the voltage and current channels are matched. An internal  
no-load threshold ensures that the ADE7761 does not exhibit  
any creep when there is no load.  
The ADE7761 supplies average active power information on the  
low frequency outputs F1 and F2. The CF logic output gives  
instantaneous active power information.  
Rev. A | Page 3 of 28  
ADE7761  
SPECIFICATIONS  
VDD = 5 V 5%, AGND = DGND = 0 V, on-chip reference, on-chip oscillator, TMIN to TMAX = –40°C to +85°C.  
Table 1.  
Parameter  
Value  
Unit  
Test Conditions/Comments  
ACCURACY1  
Measurement Error2  
0.1  
% of reading, typ  
Over a dynamic range of 500 to 1  
Phase Error between Channels  
(PF = 0.8 Capacitive)  
(PF = 0.5 Inductive)  
0.05  
0.05  
Degrees, max  
Degrees, max  
Phase lead 37°  
Phase lag 60°  
AC Power Supply Rejection2  
Output Frequency Variation  
DC Power Supply Rejection2  
Output Frequency Variation  
FAULT DETECTION2, 3  
0.01  
0.01  
%, typ  
%, typ  
V1A = V1B = V2P = 100 mV rms  
V1A = V1B = V2P = 100 mV rms  
See the Fault Detection section  
Fault Detection Threshold  
Inactive Input <> Active Input  
Input Swap Threshold  
Inactive Input <> Active Input  
Accuracy Fault Mode Operation  
V1A Active, V1B = AGND  
V1B Active, V1A = AGND  
Fault Detection Delay  
6.25  
6.25  
%, typ  
(V1A or V1B active)  
(V1A or V1B active)  
% of larger, typ  
0.1  
0.1  
3
% of reading, typ  
% of reading, typ  
Seconds, typ  
Over a dynamic range of 500 to 1  
Over a dynamic range of 500 to 1  
Swap Delay  
3
Seconds, typ  
MISSING NEUTRAL MODE2, 4  
Missing Neutral Detection Threshold  
V2P − V2N  
See the Missing Neutral Detection section  
59.4  
mV peak, min  
Accuracy Missing Neutral Mode  
V1A Active, V1B = V2P = AGND  
V1B Active, V1A = V2P = AGND  
Missing Neutral Detection Delay  
ANALOG INPUTS  
0.1  
0.1  
3
% of reading, typ  
% of reading, typ  
Seconds, typ  
Over a dynamic range of 500 to 1  
Over a dynamic range of 500 to 1  
V1A − V1N, V1B − V1N, V2P − V2N  
Differential input  
Differential input MISCAL − V2N  
Maximum Signal Levels  
660  
660  
400  
7
10  
4
mV peak, max  
mV peak, max  
kΩ, min  
kHz, typ  
mV, max  
Input Impedance (DC)  
Bandwidth (−3 dB)  
ADC Offset Error2  
Uncalibrated error, see the Terminology section for details  
External 2.5 V reference  
Gain Error  
%, typ  
REFERENCE INPUT  
REFIN/OUT Input Voltage Range  
2.7  
2.3  
4
V, max  
V, min  
kΩ, min  
pF, max  
2.5 V + 8%  
2.5 V − 8%  
Input Impedance  
Input Capacitance  
10  
ON-CHIP REFERENCE  
Reference Error  
Temperature Coefficient  
Current Source  
200  
30  
20  
mV, max  
ppm/°C, typ  
µA, min  
ON-CHIP OSCILLATOR  
Oscillator Frequency  
Oscillator Frequency Tolerance  
450  
12  
30  
kHz  
% of reading, typ  
ppm/°C, typ  
Temperature Coefficient  
See footnotes on next page.  
Rev. A | Page 4 of 28  
 
 
 
ADE7761  
Parameter  
LOGIC INPUTS5  
Value  
Unit  
Test Conditions/Comments  
SCF, S1, and S0  
Input High Voltage, VINH  
Input Low Voltage, VINL  
Input Current, IIN  
2.4  
0.8  
3
V, min  
VDD = 5 V 5%  
VDD = 5 V 5%  
Typical 10 nA, VIN = 0 V to VDD  
V, max  
µA, max  
pF, max  
Input Capacitance, CIN  
10  
LOGIC OUTPUTS5  
CF, REVP, and FAULT  
Output High Voltage, VOH  
Output Low Voltage, VOH  
F1 and F2  
4
1
V, min  
V, max  
VDD = 5 V 5%  
VDD = 5 V 5%  
Output High Voltage, VOH  
Output Low Voltage, VOH  
POWER SUPPLY  
4
1
V, min  
V, max  
VDD = 5 V 5%, ISOURCE = 10 mA  
VDD = 5 V 5%, ISINK = 10 mA  
For specified performance  
5 V − 5%  
VDD  
4.75  
5.25  
4
V, min  
V, max  
mA, max  
5 V + 5%  
VDD  
1 See plots in the Typical Performance Characteristics section.  
2 See the Terminology section for explanation of specifications.  
3 See the Fault Detection section for explanation of fault detection functionality.  
4 See the Missing Neutral Detection section for explanation of missing neutral detection functionality.  
5 Sample tested during initial release and after any redesign or process change that may affect this parameter.  
Rev. A | Page 5 of 28  
 
ADE7761  
TIMING CHARACTERISTICS  
VDD = 5 V 5%, AGND = DGND = 0 V, on-chip reference, on-chip oscillator, TMIN to TMAX = –40°C to +85°C.  
Sample tested during initial release and after any redesign or process change that may affect this parameter.  
See Figure 2.  
Table 2.  
Parameter  
Value  
Unit  
Test Conditions/Comments  
1
t1  
120  
See Table 6  
1/2 t2  
ms  
s
s
ms  
s
s
F1 and F2 Pulse Width (Logic High).  
t2  
t3  
t4  
Output Pulse Period. See the Transfer Function section.  
Time between F1 Falling Edge and F2 Falling Edge.  
CF Pulse Width (Logic High).  
CF Pulse Period. See the Transfer Function section.  
Minimum Time between F1 and F2 Pulse.  
1
90  
t5  
t6  
See Table 7  
CLKIN/4  
1 The pulse widths of F1, F2, and CF are not fixed for higher output frequencies. See the Transfer Function section.  
t1  
F1  
t6  
t2  
t3  
F2  
t4  
t5  
CF  
Figure 2. Timing Diagram for Frequency Outputs  
Rev. A | Page 6 of 28  
 
 
 
ADE7761  
ABSOLUTE MAXIMUM RATINGS  
TA = 25°C, unless otherwise noted.  
Table 3.  
Stresses above those listed under Absolute Maximum Ratings  
may cause permanent damage to the device. This is a stress  
rating only; functional operation of the device at these or any  
other conditions above those listed in the operational sections  
of this specification is not implied. Exposure to absolute  
maximum rating conditions for extended periods may affect  
device reliability.  
Parameter  
Rating  
VDD to AGND  
Analog Input Voltage to AGND  
V1AP, V1BP, V1N, V2N, V2P, MISCAL  
−0.3 V to +7 V  
−6 V to +6 V  
Reference Input Voltage to AGND  
Digital Input Voltage to DGND  
Digital Output Voltage to DGND  
Operating Temperature Range  
Industrial  
−0.3 V to VDD + 0.3 V  
−0.3 V to VDD + 0.3 V  
−0.3 V to VDD + 0.3 V  
−40°C to +85°C  
−65°C to +150°C  
150°C  
Storage Temperature Range  
Junction Temperature  
20-Lead SSOP, Power Dissipation  
θJA Thermal Impedance  
Lead Temperature, Soldering  
Vapor Phase (60 s)  
450 mW  
112°C/W  
215°C  
220°C  
Infrared (15 s)  
ESD CAUTION  
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on  
the human body and test equipment and can discharge without detection. Although this product features  
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy  
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance  
degradation or loss of functionality.  
Rev. A | Page 7 of 28  
ADE7761  
TERMINOLOGY  
Measurement Error  
For the dc PSR measurement, a reading at nominal supplies  
(5 V) is taken. A second reading is obtained with the same input  
signal levels when the power supplies are varied 5%. Any error  
introduced is again expressed as a percentage of reading.  
The error associated with the energy measurement made by the  
ADE7761 is defined by the following formula:  
Percentage Error =  
ADC Offset Error  
Energyregisteredby ADE7761 True Energy  
This refers to the dc offset associated with the analog inputs to  
the ADCs. It means that with the analog inputs connected to  
AGND, the ADCs still see a dc analog input signal. The magni-  
tude of the offset depends on the input range selection (see the  
Typical Performance Characteristics section). However, when  
HPFs are switched on, the offset is removed from the current  
channels and the power calculation is not affected by this offset.  
×100%  
True Energy  
Phase Error between Channels  
The high-pass filter (HPF) in the current channel has a phase  
lead response. To offset this phase response and equalize the  
phase response between channels, a phase correction network is  
also placed in the current channel. The phase correction net-  
work ensures a phase match between the current channels and  
voltage channels to within 0.1° over a range of 45 Hz to 65 Hz  
and 0.2° over a range 40 Hz to 1 kHz.  
Gain Error  
The gain error in the ADE7761 ADCs is defined as the differ-  
ence between the measured output frequency (minus the offset)  
and the ideal output frequency. The difference is expressed as a  
percentage of the ideal frequency, which is obtained from the  
transfer function (see the Transfer Function section).  
Power Supply Rejection  
This quantifies the ADE7761 measurement error as a percent-  
age of reading when the power supplies are varied. For the ac  
PSR measurement, a reading at nominal supplies (5 V) is taken.  
A second reading is obtained with the same input signal levels  
when an ac (175 mV rms/100 Hz) signal is introduced onto the  
supplies. Any error introduced by this ac signal is expressed as a  
percentage of reading (see the Measurement Error definition  
above).  
Rev. A | Page 8 of 28  
 
ADE7761  
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS  
V
1
2
20 F1  
F2  
DD  
V
19  
1A  
1B  
1N  
2N  
V
3
18 CF  
V
V
4
17 DGND  
ADE7761  
TOP VIEW  
(Not to Scale)  
5
REVP  
16  
V
6
15 FAULT  
2P  
14  
13  
MISCAL  
AGND  
7
RCLKIN  
INT  
8
REF  
9
12 S0  
IN/OUT  
SCF  
S1  
11  
10  
Figure 3. Pin Configuration (SSOP)  
Table 4. Pin Function Descriptions  
Pin No.  
Mnemonic  
Description  
1
VDD  
Power Supply. This pin provides the supply voltage for the digital circuitry in the ADE7761. The supply  
voltage should be maintained at 5 V 5% for specified operation. This pin should be decoupled with a  
10 µF capacitor in parallel with a ceramic 100 nF capacitor.  
2, 3  
V1A, V1B  
Analog Inputs for Channel 1 (Current Channel). These inputs are fully differential voltage inputs with  
maximum differential input signal levels of 660 mV with respect to V1N for specified operation. The  
maximum signal level at these pins is 1 V with respect to AGND. Both inputs have internal ESD  
protection circuitry, and an overvoltage of 6 V can also be sustained on these inputs without risk of  
permanent damage.  
4
V1N  
Negative Input Pin for Differential Voltage Inputs V1A and V1B. The maximum signal level at this pin is  
1 V with respect to AGND. The input has internal ESD protection circuitry, and an overvoltage of 6 V  
can also be sustained on these inputs without risk of permanent damage. The input should be directly  
connected to the burden resistor and held at a fixed potential,that is, AGND. See the Analog Inputs  
section.  
5
6
V2N  
Negative Input Pin for Differential Voltage Inputs V2P and MISCAL. The maximum signal level at this pin is  
1 V with respect to AGND. The input has internal ESD protection circuitry, and an overvoltage of 6 V  
can also be sustained on these inputs without risk of permanent damage. The input should be held at a  
fixed potential, that is, AGND. See the Analog Inputs section.  
Analog Inputs for Channel 2 (Voltage Channel). This input is fully differential voltage input with  
maximum differential input signal levels of 660 mV with respect to V2N for specified operation. The  
maximum signal level at these pins is 1 V with respect to AGND. This input has internal ESD protection  
circuitry, and an overvoltage of 6 V can also be sustained on these inputs without risk of permanent  
damage.  
V2P  
7
8
9
MISCAL  
AGND  
Analog Input for Missing Neutral Calibration. This pin can be used to calibrate the CF-F1-F2 frequencies  
in the missing neutral condition. This input is fully differential voltage input with maximum differential  
input signal levels of +660 mV with respect to V2N for specified operation. The maximum signal level at  
this pin is 1 V with respect to AGND. This input has internal ESD protection circuitry, and an  
overvoltage of 6 V can also be sustained on these inputs without risk of permanent damage.  
This pin provides the ground reference for the analog circuitry in the ADE7761, that is, ADCs and  
reference. This pin should be tied to the analog ground plane of the PCB. The analog ground plane is the  
ground reference for all analog circuitry such as antialiasing filters, and current and voltage transducers.  
For good noise suppression, the analog ground plane should be connected only to the digital ground  
plane at the DGND pin.  
REFIN/OUT  
This pin provides access to the on-chip voltage reference. The on-chip reference has a nominal value of  
2.5 V 8% and a typical temperature coefficient of 30 ppm/°C. An external reference source can also be  
connected at this pin. In either case, this pin should be decoupled to AGND with a 1 μF ceramic  
capacitor and 100 nF ceramic capacitor.  
10  
SCF  
Select Calibration Frequency. This logic input is used to select the frequency on the calibration output  
CF. Table 6 shows how the calibration frequencies are selected.  
11, 12  
S1, S0  
These logic inputs are used to select one of four possible frequencies for the digital-to-frequency  
conversion. This offers the designer greater flexibility when designing the energy meter. See the  
Selecting a Frequency for an Energy Meter Application section.  
Rev. A | Page 9 of 28  
ADE7761  
Pin No.  
Mnemonic  
Description  
13  
14  
INT  
RCLKIN  
This pin is internally used and should be connected to DGND.  
To enable the internal oscillator as a clock source on the chip, a precise low temperature drift resistor at  
nominal value of 6.2 kΩ must be connected from this pin to DGND.  
15  
FAULT  
This logic output goes active high when a fault or missing neutral condition occurs. A fault is defined as  
a condition under which the signals on V1A and V1B differ by more than 6.25%. A missing neutral  
condition is defined when the chip is powered up with no voltage at the input. The logic output is reset  
to zero when a fault or missing neutral condition is no longer detected. See the Fault Detection section  
and the Missing Neutral Mode section.  
16  
17  
REVP  
This logic output goes logic high when negative power is detected, that is, when the phase angle  
between the voltage and current signals is greater than 90°. This output is not latched and is reset when  
positive power is once again detected. The output goes high or low at the same time as a pulse is issued  
on CF.  
This pin provides the ground reference for the digital circuitry in the ADE7761, that is, multiplier, filters,  
and digital-to-frequency converter. This pin should be tied to the digital ground plane of the PCB. The  
digital ground plane is the ground reference for all digital circuitry such as counters (mechanical and  
digital), MCUs, and indicator LEDs. For good noise suppression, the analog ground plane should be  
connected only to the digital ground plane at the DGND pin.  
DGND  
18  
CF  
Calibration Frequency Logic Output. The CF logic output, active high, gives instantaneous active power  
information. This output is intended to be used for operational and calibration purposes. See the Digital-  
to-Frequency Conversion section.  
19, 20  
F2, F1  
Low Frequency Logic Outputs. F1 and F2 supply average active power information. The logic outputs  
can be used to directly drive electromechanical counters and 2-phase stepper motors.  
Rev. A | Page 10 of 28  
ADE7761  
TYPICAL PERFORMANCE CHARACTERISTICS  
1.0  
1.0  
0.8  
PF = 1  
PF = 1  
ON-CHIP REFERENCE  
ON-CHIP REFERENCE  
0.8  
–40°C  
5.25V  
0.6  
0.6  
0.4  
0.4  
+25°C  
0.2  
0.2  
0
0
5.00V  
–0.2  
–0.4  
–0.6  
–0.8  
–1.0  
–0.2  
–0.4  
–0.6  
–0.8  
–1.0  
+85°C  
4.75V  
0.1  
1.0  
10.0  
100.0  
0.1  
1.0  
10.0  
100.0  
CURRENT (% of Full Scale)  
CURRENT (% of Full Scale)  
Figure 4. Active Power Error as a Percentage of Reading with  
Internal Reference  
Figure 6. Active Power Error as a Percentage of Reading  
over Power Supply with Internal Reference  
1.5  
2.0  
1.5  
PF = 0.5  
ON-CHIP REFERENCE  
ON-CHIP REFERENCE  
1.0  
0.5  
1.0  
–40°C; PF = 0.5  
+85°C  
0.5  
0
+25°C; PF = 1  
+25°C  
0
–0.5  
–1.0  
–1.5  
–2.0  
–40°C  
+25°C; PF = 0.5  
+85°C; PF = 0.5  
–0.5  
–1.0  
0.1  
1.0  
10.0  
100.0  
0.1  
1.0  
10.0  
100.0  
CURRENT (% of Full Scale)  
CURRENT (% of Full Scale)  
Figure 5. Active Power Error as a Percentage of Reading over  
Power Factor with Internal Reference  
Figure 7. Ampere Hour Error as a Percentage of Reading in  
Missing Neutral Mode with Internal Reference  
Rev. A | Page 11 of 28  
ADE7761  
V
V
DD  
+
10µF  
100nF  
1
PS2501-1  
40A TO 80mA  
I
2kΩ  
18  
CF  
DD  
1kΩ  
1
4
2
V
1A  
TO FREQ.  
COUNTER  
RB  
33nF  
ADE7761  
2
3
1kΩ  
33nF  
1kΩ  
2kΩ  
3
4
5
V
V
V
1B  
15  
14  
FAULT  
RB  
6.2kΩ  
RCLKIN  
1N  
2N  
RB = 18Ω  
33nF  
10kΩ  
1kΩ  
12  
11  
10  
S0  
S1  
33nF  
SCF  
1MΩ  
1k33nF  
REF  
6
6
9
V
IN/OUT  
2P  
+
220V  
100nF  
10µF  
560kΩ  
MISCAL  
INT AGND DGND  
13 17  
100k33nF  
8
Figure 8. Test Circuit for Performances Curves  
Rev. A | Page 12 of 28  
ADE7761  
OPERATION  
POWER SUPPLY MONITOR  
Channel V2 (Voltage Channel)  
The output of the line voltage transducer is connected to the  
ADE7761 at this analog input. Channel V2 is a single-ended  
voltage input. The maximum peak differential signal on  
Channel 2 is 660 mV with respect to V2N. Figure 11 shows the  
maximum signal levels that can be connected to Channel 2.  
The ADE7761 contains an on-chip power supply monitor. The  
power supply (VDD) is continuously monitored by the ADE7761.  
If the supply is less than 4 V 5%, the ADE7761 goes into an  
inactive state, that is, no energy is accumulated and the CF, F1,  
and F2 outputs are disabled. This is useful to ensure correct  
device operation at power-up and during power-down. The  
power supply monitor has built-in hysteresis and filtering. This  
gives a high degree of immunity to false triggering due to noisy  
supplies.  
V2  
V
2P  
+660mV + V  
CM  
V2  
DIFFERENTIAL INPUT  
±660mV MAX PEAK  
V
V
2N  
CM  
V
COMMON MODE  
±100mV MAX  
CM  
The power supply and decoupling for the part should be such  
that the ripple at VDD does not exceed 5 V 5% as specified for  
normal operation.  
–660mV + V  
CM  
Figure 11. Maximum Signal Levels, Channel 2  
V
DD  
The differential voltage V2P–V2N must be referenced to a  
common mode (usually AGND). The analog inputs of the  
ADE7761 can be driven with common-mode voltages of up to  
100 mV with respect to AGND. However, the best results are  
achieved using a common mode equal to AGND.  
5V  
4V  
0V  
TIME  
MISCAL Input  
ADE7761  
REVP - FAULT - CF -  
F1 - F2 OUTPUTS  
INACTIVE  
ACTIVE  
INACTIVE  
The input for the power calibration in missing neutral mode is  
connected to the ADE7761 at this analog input. MISCAL is a  
single-ended voltage input. It is recommended to use a dc signal  
derived from the voltage reference to drive this pin. The maxi-  
mum peak differential signal on MISCAL is +660 mV with  
respect to V2N. Figure 12 shows the maximum signal levels that  
can be connected to the MISCAL pin.  
Figure 9. On-Chip Power Supply Monitoring  
ANALOG INPUTS  
Channel V1 (Current Channel)  
The voltage outputs from the current transducers are connected  
to the ADE7761 here. Channel V1 has two voltage inputs, V1A  
and V1B. These inputs are fully differential with respect to V1N.  
However, at any one time, only one is selected to perform the  
power calculation (see the Fault Detection section).  
MISCAL  
MISCAL  
MISCAL  
+660mV + V  
CM  
CM  
DIFFERENTIAL INPUT  
±660mV MAX PEAK  
V
2N  
V
COMMON MODE  
±100mV MAX  
V
CM  
The maximum peak differential signal on V1A–V1N and V1B–V1N  
is 660 mV.  
AGND  
Figure 10 shows the maximum signal levels on V1A, V1B, and V1N.  
The differential voltage signal on the inputs must be referenced  
to a common mode (usually AGND).  
Figure 12. Maximum Signal Levels, MISCAL  
The differential voltage MISCAL–V2N must be referenced to a  
common mode (usually AGND). The analog inputs of the  
ADE7761 can be driven with common-mode voltages of up to  
100 mV with respect to AGND. However, best results are  
achieved using a common mode equal to AGND.  
V
1A  
DIFFERENTIAL INPUT A  
±660mV MAX PEAK  
V
, V  
1A 1B  
V1  
+660mV + V  
CM  
V
1N  
COMMON MODE  
±100mV MAX  
V
CM  
V
CM  
Typical Connection Diagrams  
V1  
AGND  
Figure 13 shows a typical connection diagram for Channel V1.  
The analog inputs are being used to monitor both the phase  
and neutral currents. Because of the large potential difference  
between the phase and neutral, two current transformers (CTs)  
must be used to provide the isolation. Note that both CTs are  
referenced to analog ground (AGND); the common-mode  
–660mV + V  
DIFFERENTIAL INPUT B  
±660mV MAX PEAK  
CM  
V
1B  
Figure 10. Maximum Signal Levels, Channel 1  
Rev. A | Page 13 of 28  
 
 
 
 
ADE7761  
voltage, therefore, is 0 V. The CT turns ratio and burden resistor  
(RB) are selected to give a peak differential voltage of 660 mV.  
INTERNAL OSCILLATOR  
The nominal internal oscillator frequency is 450 kHz when  
used with the recommended ROSC resistor value of 6.2 kΩ  
between RCLKIN and DGND (see Figure 16).  
Figure 14 shows two typical connections for Channel V2. The  
first option uses a potential transformer (PT) to provide  
complete isolation from the main voltage. In the second option,  
the ADE7761 is biased around the neutral wire, and a resistor  
divider is used to provide a voltage signal that is proportional to  
the line voltage. Adjusting the ratio of RA and RB + VR is a  
convenient way of carrying out a gain calibration on the meter.  
The internal oscillator frequency is inversely proportional to the  
value of this resistor. Although the internal oscillator operates  
when used with a ROSC resistor value between 5 kΩ and 12 kΩ, it  
is recommended to choose a value within the range of the  
nominal value.  
Figure 15 shows a typical connection for MISCAL input. The  
voltage reference input (REFIN/OUT) is used as a dc reference to  
set the MISCAL voltage. Adjusting the level of MISCAL to  
calibrate the meter in missing neutral mode can be done by  
changing the ratio of RC and RD + VR1. When the internal  
reference is used, the values of RC, RD, and VR1 must be chosen  
to limit the current sourced by the internal reference sourcing  
current to below the specified 20 µA. Therefore, because VREF  
internal = 2.5 V, RC + RD + VR1 > 600 kΩ.  
The output frequencies on CF, F1, and F2 are directly propor-  
tional to the internal oscillator frequency; therefore, the resistor  
ROSC must have a low tolerance and low temperature drift. A low  
tolerance resistor limits the variation of the internal oscillator  
frequency. Small variation of the clock frequency and conse-  
quently of the output frequencies from meter to meter  
contributes to a smaller calibration range of the meter. A low  
temperature drift resistor directly limits the variation of the  
internal clock frequency over temperature. The stability of the  
meter to external variation is then better ensured by design.  
V
R
F
1A  
CT  
ADE7761  
RB  
RB  
C
C
F
F
IP  
IN  
AGND  
4k  
2.5V  
INTERNAL  
OSCILLATOR  
V
V
1N  
1B  
REFERENCE  
9
14  
17  
CT  
REF  
RCLKIN  
DGND  
IN/OUT  
R
F
R
OSC  
Figure 13. Typical Connection for Channel 1  
Figure 16. Internal Oscillator Connection  
V
R
R
2P  
F
C
C
±660mV  
AGND  
F
V
ANALOG-TO-DIGITAL CONVERSION  
2N  
F
F
The analog-to-digital conversion in the ADE7761 is carried out  
using second-order Σ-Δ ADCs. Figure 17 shows a first-order  
(for simplicity) Σ-Δ ADC. The converter is made up of two  
parts: the Σ-Δ modulator and the digital low-pass filter.  
RA*  
RB*  
VR*  
C
F
V
2P  
MCLK  
ANALOG  
LOW-PASS FILTER  
V
R
2N  
F
LATCHED  
COMPAR-  
ATOR  
INTEGRATOR  
DIGITAL  
LOW-PASS FILTER  
C
T
R
*RB + VR = RF  
V
REF  
1
24  
C
Figure 14. Typical Connection for Channel 2  
....10100101....  
REF  
IN/OUT  
1-BIT DAC  
RC  
C
F
RD  
Figure 17. First-Order Σ-∆ ADC  
MISCAL  
VR1  
V
A Σ-Δ modulator converts the input signal into a continuous  
serial stream of 1s and 0s at a rate determined by the sampling  
clock. In the ADE7761, the sampling clock is equal to CLKIN.  
The 1-bit DAC in the feedback loop is driven by the serial data  
stream. The DAC output is subtracted from the input signal. If  
the loop gain is high enough, the average value of the DAC  
R
2N  
F
C
F
Figure 15. Typical Connection for MISCAL  
Rev. A | Page 14 of 28  
 
 
 
 
ADE7761  
output (and, therefore, the bit stream) approaches that of the  
input signal level. For any given input value in a single sampling  
interval, the data from the 1-bit ADC is virtually meaningless.  
Only when a large number of samples are averaged is a  
meaningful result obtained. This averaging is carried out in the  
second part of the ADC, the digital low-pass filter. By averaging  
a large number of bits from the modulator, the low-pass filter  
can produce 24-bit data words that are proportional to the input  
signal level.  
Antialias Filter  
Figure 18 also shows an analog low-pass filter (RC) on input to  
the modulator. This filter is present to prevent aliasing. Aliasing  
is an artifact of all sampled systems, which means that fre-  
quency components in the input signal to the ADC that are  
higher than half the sampling rate of the ADC appear in the  
sampled signal frequency below half the sampling rate.  
Figure 19 illustrates the effect.  
In Figure 19, frequency components (arrows shown in black)  
above half the sampling frequency (also known as the Nyquist  
frequency), that is, 225 kHz, are imaged or folded back down  
below 225 kHz (arrows shown in gray). This happens with all  
ADCs no matter what the architecture. In the example shown,  
only frequencies near the sampling frequency (450 kHz) move  
into the band of interest for metering (40 Hz to 1 kHz). This  
fact allows the use of a very simple low-pass filter to attenuate  
these frequencies (near 250 kHz) and thereby prevent distortion  
in the band of interest. A simple RC filter (single pole) with a  
corner frequency of 10 kHz produces an attenuation of  
approximately 33 dB at 450 kHz (see Figure 19). This is  
sufficient to eliminate the effects of aliasing.  
The Σ-Δ converter uses two techniques to achieve high  
resolution from what is essentially a 1-bit conversion technique.  
The first is oversampling, which means that the signal is  
sampled at a rate (frequency) that is many times higher than the  
bandwidth of interest. For example, the sampling rate in the  
ADE7761 is CLKIN (450 kHz) and the band of interest is 40 Hz  
to 1 kHz. Oversampling has the effect of spreading the  
quantization noise (noise due to sampling) over a wider  
bandwidth. With the noise spread more thinly over a wider  
bandwidth, the quantization noise in the band of interest is  
lowered (see Figure 18).  
However, oversampling alone is not an efficient enough method  
to improve the signal-to-noise ratio (SNR) in the band of inter-  
est. For example, an oversampling ratio of 4 is required just to  
increase the SNR by only 6 dB (1 bit). To keep the oversampling  
ratio at a reasonable level, it is possible to shape the quantization  
noise so that the majority of the noise lies at the higher frequen-  
cies. This is what happens in the Σ-Δ modulator; the noise is  
shaped by the integrator, which has a high-pass type response  
for the quantization noise. The result is that most of the noise is  
at the higher frequencies where it can be removed by the digital  
low-pass filter. This noise shaping is also shown in Figure 18.  
ANTIALIASING EFFECTS  
SAMPLING  
FREQUENCY  
IMAGE  
FREQUENCIES  
0
1kHz  
225kHz  
450kHz  
FREQUENCY (Hz)  
Figure 19. ADC and Signal Processing in Current Channel or Voltage Channel  
ANTIALIAS FILTER (RC)  
DIGITAL FILTER  
SAMPLING FREQUENCY  
SHAPED NOISE  
ACTIVE POWER CALCULATION  
SIGNAL  
NOISE  
The ADCs digitize the voltage signals from the current and  
voltage transducers. A high-pass filter in the current channel  
removes any dc component from the current signal. This  
eliminates any inaccuracies in the active power calculation due  
to offsets in the voltage or current signals (see the HPF and  
Offset Effects section).  
0
1kHz  
225kHz  
FREQUENCY (Hz)  
450kHz  
HIGH RESOLUTION  
SIGNAL  
NOISE  
OUTPUT FROM  
DIGITAL LFP  
The active power calculation is derived from the instantaneous  
power signal. The instantaneous power signal is generated by a  
direct multiplication of the current and voltage signals. To  
extract the active power component (dc component), the  
instantaneous power signal is low-pass filtered. Figure 20  
illustrates the instantaneous active power signal and shows how  
the active power information can be extracted by low-pass  
filtering the instantaneous power signal. This scheme correctly  
calculates active power for nonsinusoidal current and voltage  
waveforms at all power factors. All signal processing is carried  
out in the digital domain for superior stability over temperature  
and time.  
0
1kHz  
225kHz  
FREQUENCY (Hz)  
450kHz  
Figure 18. Noise Reduction Due to Oversampling and  
Noise Shaping in the Analog Modulator  
Rev. A | Page 15 of 28  
 
 
ADE7761  
INSTANTANEOUS  
POWER SIGNAL  
INSTANTANEOUS  
ACTIVE POWER SIGNAL  
The low frequency output of the ADE7761 is generated by  
accumulating this active power information. This low frequency  
inherently means a long accumulation time between output  
pulses. The output frequency is, therefore, proportional to the  
average active power. This average active power information can  
in turn be accumulated (for example, by a counter) to generate  
active energy information. Because of its high output frequency  
and therefore shorter integration time, the CF output is propor-  
tional to the instantaneous active power. This is useful for  
system calibration purposes that would take place under steady  
load conditions.  
V × I  
2
0V  
CURRENT  
VOLTAGE  
INSTANTANEOUS  
POWER SIGNAL  
INSTANTANEOUS  
ACTIVE POWER SIGNAL  
DIGITAL-TO-  
FREQUENCY  
V × I  
2
F1  
F2  
× cos(60°)  
0V  
CH1  
CH2  
ADC  
ADC  
HPF  
MULTIPLIER  
DIGITAL-TO-  
FREQUENCY  
LPF  
VOLTAGE  
CURRENT  
CF  
60°  
Figure 21. Active Power Calculation over PF  
INSTANTANEOUS  
POWER SIGNAL –p(t)  
INSTANTANEOUS  
ACTIVE POWER SIGNAL  
Nonsinusoidal Voltage and Current  
V × I  
p(t) = i(t).v(t)  
WHERE:  
The active power calculation method also holds true for  
nonsinusoidal current and voltage waveforms. All voltage and  
current waveforms in practical applications have some  
harmonic content. Using the Fourier transform, instantaneous  
voltage and current waveforms can be expressed in terms of  
their harmonic content:  
V × I  
2
v(t) = V × cos(ϖt)  
i(t) = I × cos(ϖt)  
V × I  
p(t) =  
{1 + cos (2ϖt)}  
2
TIME  
Figure 20. Signal Processing Block Diagram  
v(t) =V + 2 × V ×sin(hωt + α )  
(1)  
Power Factor Considerations  
O
h
h
The method used to extract the active power information from  
the instantaneous power signal (by low-pass filtering) is still  
valid even when the voltage and current signals are not in  
phase. Figure 21 displays the unity power factor condition and  
a displacement power factor (DPF = 0.5), that is, current signal  
lagging the voltage by 60°. If one assumes that the voltage and  
current waveforms are sinusoidal, the active power component  
of the instantaneous power signal (dc term) is given by  
h 0  
where:  
v(t) is the instantaneous voltage.  
VO is the average value.  
Vh is the rms value of voltage harmonic h.  
αh is the phase angle of the voltage harmonic.  
i(t) = IO + 2 × I ×sin(hωt +β )  
(2)  
(V × I/2) × cos(60°)  
h
h
h 0  
This is the correct active power calculation.  
where:  
i(t) is the instantaneous current.  
IO is the dc component.  
Ih is the rms value of current harmonic h.  
βh is the phase angle of the current harmonic.  
Rev. A | Page 16 of 28  
 
 
ADE7761  
Using Equations 1 and 2, the active power P can be expressed in  
terms of its fundamental active power (P1) and harmonic active  
power (PH):  
DC COMPONENT (INCLUDING ERROR TERM)  
IS EXTRACTED BY THE LPF FOR ACTIVE  
POWER CALCULATION  
V
× I  
1
1
2
P = P1 + PH  
where:  
V
V
× I  
× I  
1
0
0
1
P1 = V1 × I1 cos(Φ1 )  
(3)  
Φ1 = α1 β1  
2v  
FREQUENCY (RAD/S)  
0v  
and  
Figure 22. Effect of Channel Offsets on the Active Power Calculation  
PH  
=
V ×I ×cos(Φ )  
0.30  
0.25  
0.20  
0.15  
h
h
h
h =2  
(4)  
Φh = αh βh  
As can be seen from Equation 4, a harmonic active power  
component is generated for every harmonic, provided that  
harmonic is present in both the voltage and current waveforms.  
The power factor calculation has previously been shown to be  
accurate in the case of a pure sinusoid; the harmonic active  
power must, therefore, also correctly account for power factor,  
because it is made up of a series of pure sinusoids.  
0.10  
0.05  
0
–0.05  
–0.10  
Note that the input bandwidth of the analog inputs is 7 kHz  
with the internal oscillator frequency of 450 kHz.  
0
100 200 300 400 500 600 700 800 900 1000  
FREQUENCY (Hz)  
HPF and Offset Effects  
Figure 23. Phase Error between Channels (0 Hz to 1 kHz)  
Equation 5 shows the effect of offsets on the active power  
calculation. Figure 22 shows the effect of offsets on the active  
power calculation in the frequency domain.  
0.30  
0.25  
0.20  
0.15  
0.10  
V(t)× I(t) =  
(V0 +V1 × cos(ωt))×(I0 + I1 × cos(ωt)) =  
V1 × I1  
(5)  
V0 × I1 +  
+V0 × I1 × cos(ωt) +V1 × I0 × cos(ωt)  
2
0.05  
0
As can be seen from Equation 5 and Figure 22, an offset on  
Channel 1 and Channel 2 contributes a dc component after  
multiplication. Because this dc component is extracted by the  
LPF and used to generate the active power information, the  
offsets contribute a constant error to the active power calcula-  
tion. This problem is easily avoided in the ADE7761 with the  
HPF in Channel 1. By removing the offset from at least one  
channel, no error component can be generated at dc by the  
multiplication. Error terms at cos(ωt) are removed by the LPF  
and the digital-to-frequency conversion (see the Digital-to-  
Frequency Conversion section).  
–0.05  
–0.10  
40  
45  
50  
55  
60  
65  
70  
FREQUENCY (Hz)  
Figure 24. Phase Error between Channels (40 Hz to 70 Hz)  
The HPF in Channel 1 has an associated phase response that is  
compensated for on-chip. Figure 23 and Figure 24 show the  
phase error between channels with the compensation network  
activated. The ADE7761 is phase compensated up to 1 kHz as  
shown, which ensures correct active harmonic power  
calculation even at low power factors.  
Rev. A | Page 17 of 28  
 
 
 
ADE7761  
The output frequency on CF can be up to 2048 times higher  
than the frequency on F1 and F2. This higher output frequency  
is generated by accumulating the instantaneous active power  
signal over a much shorter time while converting it to a  
frequency. This shorter accumulation period means less  
averaging of the cos(2ωt) component. As a consequence, some  
of this instantaneous power signal passes through the digital-to-  
frequency conversion. This is not a problem in the application.  
DIGITAL-TO-FREQUENCY CONVERSION  
As previously described, the digital output of the low-pass filter  
after multiplication contains the active power information.  
However, because this LPF is not an ideal “brick wall” filter  
implementation, the output signal also contains attenuated  
components at the line frequency and its harmonics, that is,  
cos(hωt), where h = 1, 2, 3, …, and so on. The magnitude  
response of the filter is given by  
Where CF is used for calibration purposes, the frequency  
should be averaged by the frequency counter, which removes  
any ripple. If CF is being used to measure energy, such as in a  
microprocessor-based application, the CF output should also be  
averaged to calculate power. Because the outputs F1 and F2  
operate at a much lower frequency, a lot more averaging of the  
instantaneous active power signal is carried out. The result is a  
greatly attenuated sinusoidal content and a virtually ripple-free  
frequency output.  
1
H( f ) =  
(6)  
1 = ( f / 4.5Hz)2  
For a line frequency of 50 Hz, this gives an attenuation of the 2ω  
(100 Hz) component of approximately –26.9 dB. The dominat-  
ing harmonic is at twice the line frequency, cos(2ωt), due to the  
instantaneous power signal.  
Figure 25 shows the instantaneous active power signal output of  
the LPF, which still contains a significant amount of instantane-  
ous power information, cos(2ωt). This signal is then passed to  
the digital-to-frequency converter, where it is integrated  
(accumulated) over time to produce an output frequency. This  
accumulation of the signal suppresses or averages out any non-  
dc components in the instantaneous active power signal. The  
average value of a sinusoidal signal is zero. Therefore, the  
frequency generated by the ADE7761 is proportional to the  
average active power.  
TRANSFER FUNCTION  
Frequency Outputs F1 and F2  
The ADE7761 calculates the product of two voltage signals (on  
Channel 1 and Channel 2) and then low-pass filters this product  
to extract active power information. This active power infor-  
mation is then converted to a frequency. The frequency  
information is output on F1 and F2 in the form of active high  
pulses. The pulse rate at these outputs is relatively low, for  
example, 0.34 Hz maximum for ac signals with S0 = S1 = 0 (see  
Table 7). This means that the frequency at these outputs is  
generated from active power information accumulated over a  
relatively long period of time. The result is an output frequency  
that is proportional to the average active power. The averaging  
of the active power signal is implicit to the digital-to-frequency  
conversion. The output frequency or pulse rate is related to the  
input voltage signals by the following equation:  
Figure 25 also shows the digital-to-frequency conversion for  
steady load conditions: constant voltage and current. As can be  
seen in Figure 25, the frequency output CF varies over time,  
even under steady load conditions. This frequency variation is  
primarily due to the cos(2ωt) component in the instantaneous  
active power signal.  
F1  
5.70 × V1rms × V2rms × F14  
F1 F2 Frequency =  
(7)  
2
VREF  
DIGITAL-TO-  
FREQUENCY  
F1  
where:  
F2  
V
TIME  
F1 F2 Frequency is the output frequency on F1 and F2 (Hz).  
V1rms is the differential rms voltage signal on Channel 1 (V).  
V2rms is the differential rms voltage signal on Channel 2 (V).  
MULTIPLIER  
FOUT  
DIGITAL-TO-  
FREQUENCY  
LPF  
I
CF  
LPF TO EXTRACT  
ACTIVE POWER  
(DC TERM)  
V
REF is the reference voltage (2.5 V 8%) (V).  
1–4 is one of four possible frequencies selected by using the  
logic inputs S0 and S1 (see Table 5).  
F
TIME  
0
ϖ
2ϖ  
FREQUENCY (Rad/s)  
INSTANTANEOUS ACTIVE POWER SIGNAL (FREQUENCY DOMAIN)  
Figure 25. Active Power to Frequency Conversion  
Rev. A | Page 18 of 28  
 
ADE7761  
Table 5. F1–4 Frequency Selection  
Note that if the on-chip reference is used, actual output  
frequencies may vary from device to device due to a reference  
tolerance of 8%.  
S1  
S0  
F1–4 (Hz)1  
1.72  
OSC/CLKIN2  
OSC/218  
0
0
0
1
3.44  
OSC/217  
1
0
6.86  
OSC/216  
OSC/215  
5.70× 0.66 × 0.66 × 1.72 Hz  
F1 F2 Frequency =  
= 0.34 Hz  
2 × 2 ×2.52  
1
1
13.7  
1 Values are generated using the nominal frequency of 450 kHz.  
2 F1–4 are a binary fraction of the master clock and, therefore, vary with the  
internal oscillator frequency (OSC).  
CF Frequency = F1 F2 × 64 = 22.0 Hz  
Frequency Output CF  
As can be seen from these two example calculations, the  
maximum output frequency for ac inputs is always half of that  
for dc input signals. Table 7 shows a complete listing of all  
maximum output frequencies for ac signals.  
The pulse output calibration frequency (CF) is intended for use  
during calibration. The output pulse rate on CF can be up to  
2048 times the pulse rate on F1 and F2. The lower the F1–4  
frequency selected, the higher the CF scaling. Table 6 shows  
how the two frequencies are related, depending on the states of  
the logic inputs S0, S1, and SCF. Because of its relatively high  
pulse rate, the frequency at this logic output is proportional to  
the instantaneous active power. As with F1 and F2, the  
frequency is derived from the output of the low-pass filter after  
multiplication. However, because the output frequency is high,  
this active power information is accumulated over a much  
shorter time. Therefore, less averaging is carried out in the  
digital-to-frequency conversion. With much less averaging of  
the active power signal, the CF output is much more responsive  
to power fluctuations (see Figure 20).  
Table 7. Maximum Output Frequency on CF, F1, and F2 for  
AC Inputs  
CF to  
F1, F2 Maximum  
SCF S1 S0 Frequency (Hz)  
CF Maximum  
Frequency (Hz)  
F1  
Ratio  
1
0
1
0
1
0
1
0
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0.34  
0.34  
0.68  
0.68  
1.36  
1.36  
2.72  
2.72  
43.52  
21.76  
43.52  
21.76  
43.52  
21.76  
43.52  
5570  
128  
64  
64  
32  
32  
16  
16  
2048  
Table 6. Relationship between CF and F1, F2 Frequency  
Outputs  
FAULT DETECTION  
The ADE7761 incorporates a novel fault detection scheme that  
warns of fault conditions and allows the ADE7761 to continue  
accurate billing during a fault event. The ADE7761 does this by  
continuously monitoring both the phase and neutral (return)  
currents. A fault is indicated when these currents differ by more  
than 6.25%. However, even during a fault, the output pulse rate  
on F1 and F2 is generated using the larger of the two currents.  
Because the ADE7761 looks for a difference between the voltage  
signals on V1A and V1B, it is important that both current trans-  
ducers be closely matched.  
SCF  
S1  
S0  
F1–4 (Hz)  
CF Frequency Output  
128 × F1, F2  
64 × F1, F2  
1
0
0
0
0
0
1.72  
1.72  
1
0
1
3.44  
64 × F1, F2  
0
0
1
3.44  
32 × F1, F2  
1
1
0
6.86  
32 × F1, F2  
0
1
0
6.86  
16 × F1, F2  
1
1
1
13.7  
16 × F1, F2  
0
1
1
13.7  
2048 × F1, F2  
Example  
On power-up, the output pulse rate of the ADE7761 is pro-  
portional to the product of the voltage signals on V1A and  
Channel 2. If there is a difference of greater than 6.25% between  
In this example, if ac voltages of 660 mV peak are applied to  
V1 and V2, then the expected output frequency on CF, F1, and  
F2 is calculated as follows:  
V1A and V1B on power-up, the fault indicator (FAULT) becomes  
active after about 1 s. In addition, if V1B is greater than V1A, the  
ADE7761 selects V1B as the input. The fault detection is  
automatically disabled when the voltage signal on Channel 1 is  
less than 0.3% of the full-scale input range. This eliminates false  
detection of a fault due to noise at light loads.  
F
1–4 = 1.7 Hz, SCF = S1 = S0 = 0  
V1rms = rms of 660 mV peak ac = 0.66/√ V  
2
V2rms = rms of 660 mV peak ac = 0.66/√ V  
2
V
REF = 2.5 V (nominal reference value)  
Rev. A | Page 19 of 28  
 
 
 
ADE7761  
Fault with Active Input Greater than Inactive Input  
Calibration Concerns  
If V1A is the active current input (that is, being used for billing),  
and the voltage signal on V1B (inactive input) falls below 93.75%  
of V1A, the fault indicator becomes active. Both analog inputs are  
filtered and averaged to prevent false triggering of this logic  
output. As a consequence of the filtering, there is a time delay of  
approximately 3 s on the logic output FAULT after the fault  
event. The FAULT logic output is independent of any activity on  
outputs F1 or F2. Figure 26 shows one condition under which  
FAULT becomes active. Because V1A is the active input and it is  
still greater than V1B, billing is maintained on V1A, that is, no  
swap to the V1B input occurs. V1A remains the active input.  
Typically, when a meter is being calibrated, the voltage and  
current circuits are separated as shown in Figure 28. This means  
that current passes through only the phase or neutral circuit.  
Figure 28 shows current being passed through the phase circuit.  
This is the preferred option, because the ADE7761 starts billing  
on the input V1A on power-up. The phase circuit CT is con-  
nected to V1A in the diagram. Since there is no current in the  
neutral circuit, the FAULT indicator comes on under these  
conditions. However, this does not affect the accuracy of the  
calibration and can be used as a means to test the functionality  
of the fault detection.  
FAULT  
FILTER  
AND  
V
R
F
1A  
V
V
1A  
1A  
IB  
CT  
COMPARE  
V
A
B
1B  
V
V
RB  
RB  
TO  
C
C
1A  
1B  
V
F
F
1A  
MULTIPLIER  
0V  
AGND  
V
V
1N  
1B  
V
V
1N  
AGND  
IB  
0V  
TEST  
CURRENT  
V
< 93.75% OF V  
1A  
1B  
CT  
FAULT  
R
F
1B  
RA*  
RB*  
VR*  
C
F
<0  
>0  
ACTIVE POINT – INACTIVE INPUT  
V
V
2P  
6.25% OF ACTIVE INPUT  
R
F
2N  
V
Figure 26. Fault Conditions for Active Input Greater than Inactive Input  
C
T
240V RMS  
*RB + VR = RF  
Fault with Inactive Input Greater than Active Input  
Figure 28. Fault Conditions for Inactive Input Greater than Active Input  
Figure 27 illustrates another fault condition. If the difference  
between V1B, the inactive input, and V1A, the active input (that is,  
being used for billing), becomes greater than 6.25% of V1B, the  
FAULT indicator goes active, and there is also a swap over to the  
V1B input. The analog input V1B becomes the active input. Again,  
there is a time constant of about 3 s associated with this swap.  
If the neutral circuit is chosen for the current circuit in the  
arrangement shown in Figure 28, this may have implications for  
the calibration accuracy. The ADE7761 powers up with the V1A  
input active as normal. However, because there is no current in  
the phase circuit, the signal on V1A is zero. This causes a fault to  
be flagged and the active input to be swapped to V1B (neutral).  
The meter can be calibrated in this mode, but the phase and  
neutral CTs might differ slightly. Because under no-fault condi-  
tions all billing is carried out using the phase CT, the meter  
should be calibrated using the phase circuit. Of course, both  
phase and neutral circuits can be calibrated.  
V1A does not swap back to being the active channel until V1A is  
greater than V1B and the difference between V1A and V1B—in this  
order—becomes greater than 6.25% of V1A. However, the  
FAULT indicator becomes inactive as soon as V1A is within  
6.25% of V1B. This threshold eliminates potential chatter  
between V1A and V1B.  
FAULT  
FILTER  
AND  
COMPARE  
V
V
1A  
1A  
MISSING NEUTRAL MODE  
V
A
B
1B  
The ADE7761 integrates a novel fault detection that warns and  
allows the ADE7761 to continue to bill in case a meter is  
connected to only one wire (see Figure 29). For correct  
operation of the ADE7761 in this mode, the VDD pin of the  
ADE7761 must be maintained within the specified range (5 V  
5%). The missing neutral detection algorithm is designed to  
work over a line frequency of 45 Hz to 55 Hz.  
V
V
TO  
1A  
1B  
MULTIPLIER  
0V  
V
V
1N  
1B  
AGND  
V
< 93.75% OF V  
1B  
1A  
FAULT + SWAP  
<0  
>0  
ACTIVE POINT – INACTIVE INPUT  
6.25% OF INACTIVE INPUT  
Figure 27. Fault Conditions for Inactive Input Greater than Active Input  
Rev. A | Page 20 of 28  
 
 
 
ADE7761  
V
R
1A  
F
Important Note for Billing of Active Energy  
CT  
IB  
The ADE7761 provides pulse outputs—CF, F1, and F2—  
intended to be used for the billing of active energy. Pulses are  
generated at these outputs in two different situations.  
RB  
RB  
C
240V RMS  
POWER  
GENERATOR  
F
V1A  
0V  
V
1N  
Case 1: When the analog input V2P – V2N complies with the  
conditions described in Figure 32, CF, F1, and F2 frequencies  
are proportional to active power and can be used to bill active  
energy.  
C
F
CT  
RA*  
R
V
1B  
F
LOAD  
C
F
F
RB*  
VR*  
Case 2: When the analog input V2P – V2N does not comply with  
the conditions described in Figure 32, the ADE7761 does not  
measure active energy, but a quantity proportional to kAh. This  
quantity is used to generate pulses on the same CF, F1, and F2.  
This situation is indicated when the FAULT pin is high.  
V
V
2P  
R
2N  
C
T
*RB + VR = RF  
Figure 29. Missing Neutral System Diagram  
Analog Devices Inc. cautions users of the ADE7761:  
The ADE7761 detects a missing neutral condition by continu-  
ously monitoring the voltage channel input (V2P–V2N). The  
FAULT pin is held high when a missing neutral condition is  
detected. In this mode, the ADE7761 continues to bill the  
energy based on the signal level on the current channel (see  
Figure 30). The billing rate or frequency outputs can be adjusted  
by changing the dc level on the MISCAL pin.  
Billing active energy in Case 1 is consistent with the  
understanding of the quantity represented by pulses on  
CF, F1, and F2 outputs (watt-hour).  
Billing active energy while the ADE7761 is in Case 2 must  
be decided knowing that the entity measured by the  
ADE7761 in this case is ampere-hour and not watt-hour.  
Users should be aware of this limitation and decide if the  
ADE7761 is appropriate for their application.  
V
1A  
ADC  
A > B  
V
V
1N  
1B  
HPF  
Missing Neutral Detection  
ADC  
ADC  
ZERO  
CROSSING  
DETECTION  
B > A  
B <> A  
The ADE7761 continuously monitors the voltage input and  
detects a missing neutral condition when the voltage input peak  
value is smaller than 9% of the analog full scale or when no zero  
crossings are detected on this input (see Figure 31).  
LPF  
MISSING NEUTRAL  
GAIN ADJUSMENT  
MISCAL  
DIGITAL-  
TO-  
FREQUENCY  
CONVERTERS  
V
MISSING  
2P  
NEUTRAL  
FILTER AND  
THRESHOLD  
V2  
ADC  
F1 F2  
CF  
V
2N  
AGND  
Figure 30. Energy Calculation in Missing Neutral Mode  
|V2|  
PEAK  
< 9% OF FULL SCALE  
OR  
NO ZERO-CROSSING ON V2  
V
–V  
2P 2N  
V
–V  
2P 2N  
V
–V  
2P 2N  
FS  
FS  
FS  
9% OF FS  
0V  
0V  
0V  
Figure 31. Missing Neutral Detection  
Rev. A | Page 21 of 28  
 
 
ADE7761  
The ADE7761 leaves the missing neutral mode for normal  
operation when both conditions are no longer valid—voltage  
peak value greater than 9% of full scale and zero crossing on the  
voltage channel detected (see Figure 32).  
where:  
F1, F2 Frequency is the output frequency on F1 and F2 (Hz).  
V1rms is the differential rms voltage signal on Channel 1 (V).  
MISCALrms is the differential rms voltage signal on the MISCAL  
pin (V).  
V
MISSING  
2P  
NEUTRAL  
FILTER AND  
THRESHOLD  
V
REF is the reference voltage (2.5 V 8%) (V).  
V2  
ADC  
F
1-4 is one of four possible frequencies selected by using the  
V
2N  
AGND  
logic inputs S0 and S1 (see Table 5).  
Example  
|V2|  
PEAK  
> 9% OF FULL SCALE  
AND  
ZERO-CROSSING ON V2  
In normal mode, ac voltages of 330 mV peak are applied to V1  
and V2, and then the expected output frequency on F1 and F2 is  
calculated as follows:  
V
–V  
2P 2N  
FS  
F
1–4 = 1.7 Hz, SCF = S1 = S0 = 0  
+9% OF FS  
–9% OF FS  
V1 = rms of 330 mV peak ac = 0.33/√ V  
2
V2 = rms of 330 mV peak ac = 0.33/√ V  
2
Figure 32. Return to Normal Mode after Missing Neutral Detection  
V
REF = 2.5 V (nominal reference value)  
Missing Neutral Gain Calibration  
5.70×0.33×0.33×1.7 Hz  
When the ADE7761 is in missing neutral mode, the energy is  
billed based on the active current input signal level. The  
calibration of the frequency outputs in this mode can be done  
with the MISCAL analog input pin. In this mode, applying a dc  
voltage of 330 mV on MISCAL is equivalent to applying, in  
normal mode, a pure sine wave on the voltage input with a peak  
value of 330 mV. The MISCAL input can vary from 0 V to  
660 mV (see the Analog Inputs section). When set to 0 V, the  
frequency outputs are close to zero. When set to 660 mV dc, the  
frequency outputs are twice that when MISCAL is at 330 mV  
dc. In other words, Equation 7 can be used in missing neutral  
F1 , F2 Frequency =  
= 0.084 Hz  
2 × 2 ×2.52  
CF Frequency = F1 F2 frequency × 64 = 5.4 Hz  
In missing neutral mode, ac voltage of 330 mV peak is applied  
to V1, no signal is connected on V2, and 330 mV dc input is  
applied to MISCAL. With the ADE7761 in the same configura-  
tion as the previous example, the expected output frequencies  
on CF, F1, and F2 are  
5.70×0.33×0.33/ 2 ×1.7 Hz  
F1 , F2 Frequency =  
= 0.084 Hz  
mode by replacing V2rms by MISCALrms √ :  
2 × 2.52  
2
CF Frequency = F1 , F2 frequency × 64 = 5.4 Hz  
5.70 × MISCALrms / 2 × F14  
F1 , F2 Frequency =  
(8)  
2
VREF  
Rev. A | Page 22 of 28  
 
ADE7761  
APPLICATIONS  
For the purpose of calibration, this integration time could be  
INTERFACING TO A MICROCONTROLLER FOR  
ENERGY MEASUREMENT  
10 s to 20 s in order to accumulate enough pulses to ensure  
correct averaging of the frequency. In normal operation, the  
integration time could be reduced to 1 s or 2 s depending, for  
example, on the required update rate of a display. With shorter  
integration times on the MCU, the amount of energy in each  
update may still have a small amount of ripple, even under  
steady load conditions. However, over a minute or more, the  
measured energy has no ripple.  
The easiest way to interface the ADE7761 to a microcontroller  
is to use the CF high frequency output with the output  
frequency scaling set to 2048 × F1, F2. This is done by setting  
SCF = 0 and S0 = S1 = 1 (see Table 7). With full-scale ac signals  
on the analog inputs, the output frequency on CF is approxi-  
mately 5.5 kHz. Figure 33 illustrates one scheme that could be  
used to digitize the output frequency and carry out the  
necessary averaging mentioned in the previous section.  
SELECTING A FREQUENCY FOR AN ENERGY  
METER APPLICATION  
CF  
FREQUENCY  
RIPPLE  
As shown in Table 5, the user can select one of four frequencies.  
This frequency selection determines the maximum frequency  
on F1 and F2. These outputs are intended to be used to drive the  
energy register (electromechanical or other). Because only four  
different output frequencies can be selected, the available  
frequency selection has been optimized for a meter constant of  
100 impulses/kWh with a maximum current of between 10 A  
and 120 A. Table 8 shows the output frequency for several  
maximum currents (IMAX) with a line voltage of 240 V. In all  
cases, the meter constant is 100 impulses/kWh.  
AVERAGE  
FREQUENCY  
±10%  
TIME  
MCU  
ADE7761  
COUNTER  
CF  
Table 8. F1 and F2 Frequency at 100 Impulses/kWh  
UP/DOWN  
REVP*  
IMAX (A)  
12.5  
25  
F1 and F2 (Hz)  
0.083  
FAULT**  
LOGIC  
0.166  
40  
0.266  
*REVP MUST BE USED IF THE METER IS BIDIRECTIONAL OR  
DIRECTION OF ENERGY FLOW IS NEEDED.  
**FAULT MUST BE USED TO RECORD ENERGY IN FAULT CONDITION.  
60  
0.4  
80  
0.533  
120  
0.8  
Figure 33. Interfacing the ADE7761 to an MCU  
As shown, the frequency output CF is connected to an MCU  
counter or port, which counts the number of pulses in a given  
integration time, determined by an MCU internal timer. The  
average power, proportional to the average frequency, is given  
by  
The F1–4 frequencies allow complete coverage of this range of  
output frequencies on F1 and F2. When designing an energy  
meter, the nominal design voltage on Channel 2 (voltage)  
should be set to half-scale to allow for calibration of the meter  
constant. The current channel should also be no more than half-  
scale when the meter sees maximum load, which accommodates  
overcurrent signals and signals with high crest factors. Table 9  
shows the output frequency on F1 and F2 when both analog  
inputs are half-scale. The frequencies listed in Table 9 align well  
with those listed in Table 8 for maximum load.  
Counter  
AverageFrequency = Average ActivePower =  
Timer  
The energy consumed during an integration period is given by  
Counter  
Energy = Average Power ×Time =  
×Time = Counter  
Time  
Rev. A | Page 23 of 28  
 
 
ADE7761  
Table 9. F1 and F2 Frequency with Half-Scale AC Inputs  
No-Load Threshold  
Frequency on F1 and F2,  
Ch 1 and Ch 2,  
Half-Scale AC Inputs (Hz)  
The ADE7761 includes a no-load threshold and startup current  
feature that eliminates creep effects in the meter. The ADE7761  
is designed to issue a minimum output frequency. Any load  
generating a frequency lower than this minimum frequency  
does not cause a pulse to be issued on F1, F2, or CF. The mini-  
mum output frequency is given as 0.0045% of the full-scale  
output frequency. (See Table 7 for maximum output frequencies  
for ac signals).  
S0  
0
0
1
1
S1  
0
1
0
1
F1–4  
1.72  
3.44  
6.86  
13.5  
0.085  
0.17  
0.34  
0.68  
When selecting a suitable F1–4 frequency for a meter design, the  
frequency output at IMAX (maximum load) with a meter constant  
of 100 impulses/kWh should be compared with Column 4 of  
Table 9. The frequency that is closest in Table 9 determines the  
best choice of frequency (F1-4). For example, if a meter with a  
maximum current of 40 A is being designed, the output  
frequency on F1 and F2 with a meter constant of  
For example, an energy meter with a meter constant of  
100 impulses/kWh on F1, F2 using SCF = 1, S1 = 0, and S0 = 1,  
the maximum output frequency at F1 or F2 is 0.68 Hz and 43.52  
Hz on CF. The minimum output frequency at F1 or F2 is  
0.0045% of 0.68 Hz or 3.06 × 10–5 Hz. This is 1.96 × 10–3 Hz at  
CF (64 × F1 Hz).  
100 impulses/kWh is 0.266 Hz at 40 A and 240 V (from  
Table 8). Looking at Table 9, the closest frequency to 0.266 Hz  
in Column 4 is 0.17 Hz. Therefore, F2 (3.4 Hz; see Table 5) is  
selected for this design.  
In this example, the no-load threshold is equivalent to 1.1 W of  
load or a startup current of 4.6 mA at 240 V. Compare this value  
to the IEC61036 specification, which states that the meter must  
start up with a load equal to or less than 0.4% IB. For a 5 A (IB)  
meter, 0.4% of IB is equivalent to 20 mA.  
Frequency Outputs  
Figure 2 shows a timing diagram for the various frequency  
outputs. The high frequency CF output is intended to be used  
for communications and calibration purposes. CF produces a  
90 ms wide, active high pulse (t4) at a frequency that is propor-  
tional to active power. The CF output frequencies are given in  
Table 7. As in the case of F1 and F2, if the period of CF (t5) falls  
below 180 ms, the CF pulse width is set to half the period. For  
example, if the CF frequency is 20 Hz, the CF pulse width is  
25 ms.  
Note that the no-load threshold is not enabled when using the  
high CF frequency mode: SCF = 0, S1 = S0 = 1.  
NEGATIVE POWER INFORMATION  
The ADE7761 detects when the current and voltage channels  
have a phase shift greater than 90°. This mechanism can detect  
wrong connection of the meter or generation of negative power.  
The REVP pin output goes active high when negative power is  
detected, and active low when positive power is detected. The  
REVP pin output changes state as a pulse is issued on CF.  
Rev. A | Page 24 of 28  
 
ADE7761  
OUTLINE DIMENSIONS  
7.50  
7.20  
6.90  
20  
11  
5.60  
5.30  
5.00  
8.20  
7.80  
7.40  
1
10  
1.85  
1.75  
1.65  
2.00 MAX  
0.25  
0.09  
8°  
4°  
0°  
0.65  
BSC  
0.95  
0.75  
0.55  
0.38  
0.22  
0.05 MIN  
SEATING  
PLANE  
COPLANARITY  
0.10  
COMPLIANT TO JEDEC STANDARDS MO-150AE  
Figure 34. 20-Lead Shrink Small Outline Package [SSOP]  
(RS-20)  
Dimensions shown in millimeters  
ORDERING GUIDE  
Model  
Temperature Range  
Package Description  
Package Option  
ADE7761ARS  
ADE7761ARSRL  
ADE7761ARS-REF  
–40°C to +85°C  
–40°C to +85°C  
Shrink Small Outline Package  
Shrink Small Outline Package  
Reference Board  
RS-20  
RS-20  
Rev. A | Page 25 of 28  
ADE7761  
DISCLAIMER  
The ADE7761 provides pulse outputs—CF, F1, and F2—  
intended to be used for the billing of active energy. Pulses are  
generated at these outputs in two different situations.  
Analog Devices Inc. cautions users of the ADE7761:  
Billing active energy in Case 1 is consistent with the  
understanding of the quantity represented by pulses on  
CF, F1, and F2 outputs (watt-hour).  
Case 1: When the analog input V2P – V2N complies with the  
conditions described in Figure 32, CF, F1, and F2 frequencies  
are proportional to active power and can be used to bill active  
energy.  
Billing active energy while the ADE7761 is in Case 2 must  
be decided knowing that the entity measured by the  
ADE7761 in this case is ampere-hour and not watt-hour.  
Users should be aware of this limitation and decide if the  
ADE7761 is appropriate for their application.  
Case 2: When the analog input V2P – V2N does not comply with  
the conditions described in Figure 32, the ADE7761 does not  
measure active energy, but a quantity proportional to kAh. This  
quantity is used to generate pulses on the same CF, F1, and F2.  
This situation is indicated when the FAULT pin is high.  
Rev. A | Page 26 of 28  
ADE7761  
NOTES  
Rev. A | Page 27 of 28  
ADE7761  
NOTES  
©
2004 Analog Devices, Inc. All rights reserved. Trademarks and  
registered trademarks are the property of their respective owners.  
D04407–0–2/04(A)  
Rev. A | Page 28 of 28  

相关型号:

ADE7761ARS-REF

Energy Metering IC with On-Chip Fault and Missing Neutral Detection
ADI

ADE7761ARSRL

Energy Metering IC with On-Chip Fault and Missing Neutral Detection
ADI

ADE7761B

Energy Metering IC with On-Chip Fault and Missing Neutral Detection
ADI

ADE7761BARS

Energy Metering IC with On-Chip Fault and Missing Neutral Detection
ADI

ADE7761BARS-REF

Energy Metering IC with On-Chip Fault and Missing Neutral Detection
ADI

ADE7761BARS-RL

Energy Metering IC with On-Chip Fault and Missing Neutral Detection
ADI

ADE7761BARSZ

Energy Metering IC with On-Chip Fault and Missing Neutral Detection
ADI

ADE7761BARSZ-RL

Energy Metering IC with On-Chip Fault and Missing Neutral Detection
ADI

ADE7762

Polyphase Energy Metering IC with Phase Drop Indication
ADI

ADE7762ARW

Polyphase Energy Metering IC with Phase Drop Indication
ADI

ADE7762ARW-RL

Polyphase Energy Metering IC with Phase Drop Indication
ADI

ADE7762ARWZ

Polyphase Energy Metering IC with Phase Drop Indication
ADI