FEATURES:
• I/O Isolation 4000VAC
• High efficiency up to 83%
• No load consumption ≤ 0.3W
• Ultra small package
• Operating Temp: -25°C to +70°C
• Input: 85-305VAC, 47-440Hz, or 100-430VDC
• Over current, Over Voltage Protection
• Short Circuit Protection
Models
Single output
Efficiency
(%)
Maximum
capacitive
Load
Output
Voltage
Output
Current max
(A)
Input Voltage
Input Voltage
(VDC)
Model
(VAC/Hz)
230
VAC
(V)
(µF)
AMEL5-3.3SJZ
AMEL5-5SJZ
AMEL5-9SJZ
AMEL5-12SJZ
AMEL5-15SJZ
AMEL5-24SJZ
85-305/47-440
85-305/47-440
85-305/47-440
85-305/47-440
85-305/47-440
85-305/47-440
100-430
100-430
100-430
100-430
100-430
100-430
3.3
5
9
12
15
24
1.25
1
0.55
0.42
0.333
0.23
4000
4000
1000
820
820
330
74
78
78
80
82
83
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
Typical
Maximum
120
Units
mA
mA
A
Current (full load)
70
10
20
Inrush current <2ms (cold start)
A
Leakage current
External fuse
Input Dissipation (No Load)
0.2
0.3
mA
A
W
Recommended slow blow type
No load (110/230VAC)
1
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
3.3V output
Others
±3
±2
Voltage accuracy
%
Line regulation
Load regulation
±0.5
±1
60
50
12
%
%
10-100% load
20MHz Bandwidth, 3.3 / 5V models
20MHz Bandwidth, others
115VAC
120
100
Ripple & Noise *
mV p-p
ms
Hold-up time (minimum)
230VAC
80
Isolation Specifications
Parameters
Tested I/O voltage
Conditions
Typical
4000
>1000
Rated
Units
VAC
MΩ
60 sec
Isolation Resistance
General Specifications
Parameters
Switching frequency
Protection class
Over Current protection
Over voltage protection
Short circuit protection
Operating temperature
Storage temperature
Conditions
Auto recovery
Typical
140
Class II
Maximum
Units
KHz
≥110
% of Iout
Zener diode clamp
Continuous, Auto recovery
See derating curve
-25 to 70°C
-25 to +105
°C
°C
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-JZ
5 Watt | AC-DC / DC-DC Converter
General Specifications (continued)
Parameters
Maximum Case temperature
Temperature coefficient
Conditions
Typical
Maximum
Units
°C
% /°C
100
0.02
Cooling
Humidity
Free air convection
Non condensing
95
% RH
g
Case material
Weight
Plastic (flammability to UL 94V-0)
32
Dimensions (L x W x H)
MTBF
2.0 x 1.0 x 0.6 inches 50.80 x 25.40 x 15.16mm
> 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency approvals
cULus, CE pending
Information technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC/EN/UL 60950-1
EN55022, class B
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 3
IEC 61000-4-4 Level 3, Level 4 with recommended EMC circuit
IEC 61000-4-5 Level 3, Level 4 with recommended EMC circuit
IEC 61000-4-6 Level 3
IEC 61000-4-8 Level 3
IEC 61000-4-11, Class 2
Standards
Dimensions
50.80
(2.00)
Case Temperature
Measurement point
45.72
(1.80)
1
3
1
3
TOP VIEW
+
10.16
(0.40)
25.40
(1.00)
20.32
(0.80)
TOP VIEW
4
4
5
2
2
15.16
(0.60)
DIV: 5.08 (0.2)
Ø 1.5 (Ø 0.06)
Ø 1.00
(0.04)
Dimensions: inch (mm)
Case Tolerance:± 0.50 (0.02)
Pin Pitch Tolerance: ± 0.10 (0.004)
Pin Out Specifications
Pin
Single
1
2
3
4
AC Input (N)
AC Input (L)
+V Output
-V Output
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-JZ
5 Watt | AC-DC / DC-DC Converter
Derating
Free Air Convection at 25°C
Free Air Convection
100
80
100
80
70
Safe Operating Area
Input 110-277VAC or
140-390VDC
Safe Operating Area
60
50
60
50
40
40
20
0
20
0
85
(100)
110
277
305
70
5560
80
- 25
-10
-
20
100
0
20
40
(140)
(390)
(430)
º C
Ambient Temperature
Input Voltage VAC (VDC)
Typical application circuit
Single Output
FUSE
1A/300V
NTC
4
+ Vout
- Vout
AC L
AC L
+
MOV
S14K350
AC
DC
C1
1µF/50V
C2
AC N
AC N
3
EMC recommended circuit
Single Output
LCM
2.2mH
LDM
4.7µH/2A
FUSE
1A/300V
NTC
+Vout
+Vout
- Vout
AC L
AC N
CY1
1nF/
400VAC
+
CX
0.1µF/
310VAC
MOV
S14K350
AC
DC
C1
1µF/50V
C2
CY2
1nF/
400VAC
AC N
AC L
- Vout
GND
Model
C2
3.3 & 5 Vout
9, 12 & 15
Vout
220 µF / 35V
100 µF / 35V
47 µF / 35V
24 Vout
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明