AMER120-24500AZ-F [AIMTEC]
AC/DC LED Driver; Product Weight (grams): 900; Input voltage min (V): 90; Input voltage max (V): 305; Input frequency (Hz): 47-440; Output voltage min: 12; Output voltage max: 24; Output voltage dual assymetric (y/n): Single; Output Power (W): 120; Max Output current (A): 0-5; Efficiency (%): 86; Package type: Encapsulated; Rating (IP): IP68; Mounting: Wire terminal; W (in): 1.85; L (in): 7.13; H (in): 2.32; W (mm): 47; L (mm): 181; H (mm): 59; Min Operating temperature: -40; Max operating temperature (°C): 85; Isolation (VAC): 3000; EMC compliance 1: EN 55022 Class B; Case material: Aluminum;型号: | AMER120-24500AZ-F |
厂家: | AIMTEC |
描述: | AC/DC LED Driver; Product Weight (grams): 900; Input voltage min (V): 90; Input voltage max (V): 305; Input frequency (Hz): 47-440; Output voltage min: 12; Output voltage max: 24; Output voltage dual assymetric (y/n): Single; Output Power (W): 120; Max Output current (A): 0-5; Efficiency (%): 86; Package type: Encapsulated; Rating (IP): IP68; Mounting: Wire terminal; W (in): 1.85; L (in): 7.13; H (in): 2.32; W (mm): 47; L (mm): 181; H (mm): 59; Min Operating temperature: -40; Max operating temperature (°C): 85; Isolation (VAC): 3000; EMC compliance 1: EN 55022 Class B; Case material: Aluminum 输出元件 |
文件: | 总10页 (文件大小:448K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Click on Series name for product info on aimtec.com
Series AMER120-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
• AC-DC Constant Current or Constant
Voltage LED Driver
• Input range 90-305VAC/47-440Hz
• High Efficiency up to 88%
• Operating temperature -40 to 85°C
• Dimmable via resistive
•
•
•
•
Over Current Protection
Short Circuit Protection
Waterproof Case rated IP68
Power Factor Correction
• 5 Years Limited Warranty
Models
Single output
Max
Output
Efficiency
Output
Current
(A)
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Output
Power
Voltage
Range
(%)
Model
Mode of Operation
③
115
230
277
①
③
VAC
VAC
VAC
(W)
(V)
Constant Current
87
87
87
87
85
88
88
88
88
86
86
88
88
88
87
AMER120-50250AZ
AMER120-36340AZ
AMER120-24500AZ
125
122.4
120
36-50
24-36
12-24
0-2.5
0-3.4
0-5
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
②
Constant Voltage
Constant Current
②
Constant Voltage
Constant Current
②
Constant Voltage
86
86
87
Add Suffix “-F”
No dimming option
①
Exceeding the maximum output power will permanently damage the converter.
②
The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No
dimming option in the case.
③
In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models
can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number when
ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-sale
AMER120-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
Typical
Maximum
1800
800
Units
mA
mA
mA
A
Current (full load)
700
45
Inrush current <2ms (cold start)
Leakage current
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
60
70
0.25
3.5
A
A
mA
mA
0.98
0.94
0.92
3
Power factor
230 VAC
277 VAC
Recommended slow blow type
External fuse
Start-up time
A
ms
900
www.aimtec.com
F 052.1e R3.AF
Tel: +1 514 620 2722
1 of 10
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Output Specifications
Parameters
Current accuracy
Line regulation
Conditions
Typical
±3
Maximum
Units
%
%
LL-HL
±2
Load regulation
Ripple & Noise
Hold-up time
0-100% load
20MHz Bandwidth
±3
150
80
%
mV p-p
ms
④
Current adjustment range⑤
100-10
%
④
Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor.
Note: from 0% to 10% dimming adjustment signal instability may be present.
⑤
Isolation Specifications
Parameters
Conditions
Typical
Rated
3750
2000
500
Units
VAC
VAC
VAC
MΩ
I/O
3sec
Tested voltage
I/FG
O/FG
Isolation resistance
500VDC
>1000
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
125
2.57
3.47
5.07
KHz
AMER120-50250AZ
AMER120-36340AZ
AMER120-24500AZ
Over current protection
A
Over voltage protection
Short circuit protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Refer to Constant Current vs. Constant Voltage Mode curve
Auto recovery
With derating over 55°C
Refer to model application
oC
oC
100
-40 to +95
±0.02
Free air convection
oC
% / oC
Humidity
Case material
Potting
Wires
Non condensing
20~95
Aluminum
Epoxy (IP68 rated)
% RH
g
UL1015 18AWG Input & 14AWG output *20CM
900
Weight
Dimensions (L X H X W)
MTBF
181.00 x 59.00 x 47.00mm (7.13 x 2.32 x 1.85inches)
>400,000 hrs (MIL-HDBK-217F at t=+25°C)
Safety Specifications
Parameters
Agency approvals
CE
Designed to meet UL8750, IEC/EN 60950-1 standards,
EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13
Information Technology Equipment
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient / Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
EN55022 Class B
IEC/EN 61000-3-2, Class C
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 2
IEC 61000-4-4 Level 2
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 2
IEC 61000-4-8 Level 1
IEC 61000-4-11
Standards
www.aimtec.com
F 052.1e R3.AF
Tel: +1 514 620 2722
2 of 10
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Dimensions
Top View
181.00
(7.13)
4.00
(0.16)
41.00
(1.73)
27.00
(1.06)
8.00
(0.32)
End View
11.00
(0.43)
Tc
23.00
(0.91)
Side View
200.00
(8.00)
200.00
(8.00)
59.00
(2.32)
47.00
(1.85)
2.30
(0.09)
Input/Output Wires are 18 AWG 20cm
Measurements in Millimeters (inch)
Case Tolerance: ±0.5 (±0.02)
Wire connection:
Connection
Wire
Brown
Blue
AC L
AC N
Green
Ground
Red
Black
Blue (Dimming)
White (Dimming)
+V output
-V Output
+ Vs dimming
-Vs dimming
Analog (resistive) Dimming Application Circuit
Maximum Pot
Value (kΩ)
18.22
BROWN
Model Number
RED
+Vout
L
1st LED
GREEN
AMER120-50250AZ
AMER120-36340AZ
AMER120-24500AZ
1
AC
22.10
34.31
AMER120-AZ
-Vout
N
1
BLUE
BLUE
BLACK
Pot
WHITE
www.aimtec.com
F 052.1e R3.AF
Tel: +1 514 620 2722
3 of 10
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Analog (0-10V) Dimming Application Circuit
PWM (1KHz) Dimming Application Circuit
Derating
Free Air Convection
55º C
100
80
Safe Operating Area
60
40
20
0
85 100
-40 -20
0
20 40
60 80
º C
Ambient Temperature
www.aimtec.com
F 052.1e R3.AF
Tel: +1 514 620 2722
4 of 10
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Efficiency vs. Input Voltage and Output Current (CC Load)
AMER120-50250AZ
(%)
Efficiency VS. Input Voltage & Output Current
277Vac, 2.5,
115Vac
230Vac, 2.5,
90.54
115Vac, 2.5,
230Vac
90.46
115Vac, 0.5,
90.16
277Vac
87.03
277Vac, 0.5,
230Vac, 0.5,
81.16
80.4
(A)
AMER120-36340AZ
Efficiency VS. Input Voltage & Output Current
(%)
89.92
89.73
88.74
115Vac
230Vac
277Vac
87.37
277Vac, 0.68,
82.711
80.85
(A)
www.aimtec.com
F 052.1e R3.AF
Tel: +1 514 620 2722
5 of 10
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Efficiency vs. Input Voltage and Output Current (CC Load)
Continued
AMER120-24500AZ
(%)
Efficiency VS. Input Voltage & Output Current
277Vac, 5,
115Vac
230Vac, 5,
88.531
230Vac
115Vac, 5,
115Vac, 1,
86.912
88.374
277Vac
87.409
277Vac, 1,
80.944
230Vac, 1,
79.913
(A)
PFC Value vs. Output Load Current (CC Load)
AMER120-50250AZ
PFC VS. Output Voltage
(PF)
115VAC, 50,
230VAC, 50,
115VAC, 36, 1
230VAC, 36,
0.997
277VAC, 50,
277VAC, 36,
0.974
115VAC
0.984
0.969
0.949
297VAC, 50,
230VAC
297VAC, 36,
0.868
0.836
277VAC
297VAC
305VAC
305VAC, 50,
0.516
305VAC, 36,
0.502
(V)
www.aimtec.com
F 052.1e R3.AF
Tel: +1 514 620 2722
6 of 10
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
PFC Value vs. Output Load Current (CC Load)
Continued
AMER120-36340AZ
PF VS. Output Voltage
(PF)
115VAC, 24,
115VAC, 36, 1
115VAC
230VAC, 24,
0.998
230VAC, 36,
277VAC, 36,
277VAC, 24,
0.97
0.985
230VAC
294VAC, 36,
0.969
0.938
294VAC, 24,
0.787
277VAC
0.882
294VAC
305VAC
305VAC, 36,
0.518
305VAC, 24,
0.502
(V)
AMER120-24500AZ
PF VS. Output Voltage
(PF)
115VAC, 12,
115VAC, 24, 1
230VAC, 24,
115VAC
230VAC, 12,
0.998
277VAC, 24,
0.986
277VAC, 12,
0.953
230VAC
0.97
0.91
297VAC, 24,
277VAC
0.848
297VAC, 12,
0.755
297VAC
305VAC
305VAC, 24,
0.519
305VAC, 12,
0.492
(V)
www.aimtec.com
F 052.1e R3.AF
Tel: +1 514 620 2722
7 of 10
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Constant Current Mode vs. Constant Voltage Mode
AMER120-50250AZ
Constant Current Vs Constant Voltage
(A)
115 & 230
Vac, 36, 2.5
115 & 230
Vac, 50, 2.5
36
38
40
115 & 230
115 & 230
Vac, 52, 0
Vac, 50.8, 0
(V)
AMER120-36340AZ
Constant Current Vs Constant Voltage
(A)
115 & 230
Vac, 24, 3.4
24
26
28
30
36
115 & 230
Vac, 36.5, 0
115 & 230
Vac, 38, 0
(V)
www.aimtec.com
F 052.1e R3.AF
Tel: +1 514 620 2722
8 of 10
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Constant Current Mode vs. Constant Voltage Mode
Continued
AMER120-24500AZ
(A)
Constant Current Vs Constant Voltage
115 & 230
Vac, 12, 5
115 & 230
Vac, 24, 5
12
14
16
115 & 230
Vac, 26, 0
115 & 230
Vac, 24.39, 0
(V)
Output Current vs. Radj
AMER120-50250AZ
Output Current VS. Dimming-Resistance
(A)
115 & 230
0
Vac, 18.22,
115 & 230
115 & 230
0.0633
2.5
Vac, 3.2, 2.25
Vac, 1.6, 2
115 & 230
115 & 230
Vac, 0.966,
115 & 230
Vac, 0.641,
1.75
Vac, 0.437,
1.5
115 & 230
115 & 230
1.25
Vac, 0.298, 1
115 & 230
Vac, 0.198,
115 & 230
Vac, 0.122,
0.75
Vac, 0.0633,
0.5
115 & 230
0.25
Vac, 0, 0
K(Ω)
www.aimtec.com
F 052.1e R3.AF
Tel: +1 514 620 2722
9 of 10
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Output Current vs. Radj
Continued
AMER120-36340AZ
Output Current VS. Dimming-Resistance
(A)
115 & 230
115 & 230
115 & 230
Vac, 3.38,
Vac, 1.663,
0
Vac, 22.1, 3.4
0.0726
3.06
115 & 230
115 & 230
2.72
Vac, 1.008,
115 & 230
Vac, 0.6663,
2.38
115 & 230
Vac, 0.4578,
2.04
115 & 230
Vac, 0.3142,
1.7
115 & 230
Vac, 0.21134,
1.36
115 & 230
Vac, 0.1337,
1.02
Vac, 0.0726,
0.68
115 & 230
0.34
Vac, 0, 0
K(Ω)
AMER120-24500AZ
(A)
Output Current VS. Dimming-Resistance
115 & 230
Vac, 34.31, 5
115 & 230
Vac, 3.582,
0
4.5
115 & 230
115 & 230
Vac, 1.723, 4
Vac, 1.017,
115 & 230
115 & 230
3.5
Vac, 0.669, 3
Vac, 0.463,
115 & 230
115 & 230
2.5
Vac, 0.314, 2
Vac, 0.197,
115 & 230
115 & 230
1.5
Vac, 0.143, 1
Vac, 0.0736,
0.5
(KΩ)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R3.AF
Tel: +1 514 620 2722
10 of 10
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明