AOZ1300  
Programmable 4A Power Distribution Switch  
General Description  
Features  
The AOZ1300 is a current-limited power distribution  
switch intended for applications that require circuit  
protection. The device operates from a 2.7V to 6.0V  
input supply and provides up to 4A load current.  
AOZ1300 offers robust fault protection features including  
over-current/short-circuit protection and thermal overload  
protection. The current limit is programmable with an  
external resistor. An open-drain fault indicator is provided  
to alert a system controller of thermal overload, over-  
current, and short-circuit events. A 24ms fault blanking  
time eliminates false alarms.  
40mmaximum on-resistance  
4A maximum continuous current  
2.7V to 6.0V operating voltage  
Resistor programmable current limit  
Reverse current blocking  
Thermal overload protection  
Very fast short-circuit response time  
Fault latch with 24ms blanking time  
Open-drain fault indicator  
1µA shutdown current  
The AOZ1300 employs internal soft-start circuitry to  
control inrush current due to highly capacitive loads  
associated with hot-plug events. An adjustable slew rate  
control pin provides additional slew rate control if needed.  
Applications  
Docking stations  
Notebook PCs  
The AOZ1300 is available in SO-8 package.  
RAID systems  
Telecom and Server hot-plug  
USB Power Distribution  
Compact PCI adapter Cards  
Typical Application  
VOUT  
VIN  
TO USB  
PORT  
IN  
OUT  
C2  
4.7µF  
C1  
1µF  
R1  
100kΩ  
AOZ1300  
FLT  
EN  
FAULT  
OFF ON  
GND  
ISET  
SLEW  
R2  
10kΩ  
C3  
10nF  
Figure 1. High Current USB Host  
Rev. 1.3 August 2008  
www.aosmd.com  
Page 1 of 12  
AOZ1300  
Ordering Information  
Part Number  
Temperature Range  
Package  
Environmental  
AOZ1300AI  
-40°C to +85°C  
-40°C to +85°C  
SO-8  
SO-8  
RoHS Compliant  
Green Product  
AOZ1300AIL  
All AOS products are offered in packages with Pb-free plating and compliant to RoHS standards.  
Parts marked as Green Products (with “Lsuffix) use reduced levels of Halogens, and are also RoHS compliant.  
Please visit www.aosmd.com/web/quality/rohs_compliant.jsp for additional information.  
Pin Configuration  
1
2
3
4
8
7
6
5
IN  
SLEW  
GND  
OUT  
IC  
FLT  
EN  
ISET  
SO-8  
(Top View)  
Pin Description  
Pin Number  
Pin Name  
Pin Function  
1
2
IN  
Switch Power Input. IN also supplies power to internal circuitry.  
SLEW  
Slew Rate Control Pin. Leaving this pin open results in a minimum output slew rate.  
Connect a capacitor from SLEW to GND to increase output slew rate.  
3
4
GND  
ISET  
Ground.  
Current-Limit Setting Pin. Connect a resistor from ISET to GND to set the current-  
limit.  
5
6
7
8
EN  
Enable Input. Pull EN high to enable the device. The part enters into low-power  
shutdown when EN is pulled low.  
FLT  
IC  
Fault Indicator. FLT is an open-drain output. FLT is asserted low during over-current  
or thermal overload events. FLT is asserted after the fault blanking period.  
Internally Connected Pin. No external connection is allowed to this pin. Leave this  
pin floating.  
OUT  
Switch Output Pin.  
Rev. 1.3 August 2008  
www.aosmd.com  
Page 2 of 12  
AOZ1300  
Absolute Maximum Ratings  
Exceeding the Absolute Maximum ratings may damage the  
device.  
Recommend Operating Ratings  
The device is not guaranteed to operate beyond the Maximum  
Operating Ratings.  
Parameter  
Rating  
Parameter  
Rating  
IN, OUT, EN, FLT, ISET, SLEW to GND  
OUT Maximum Continuous Current  
6.5V  
Input Supply Voltage (V )  
+2.7V to +6.0V  
-40°C to +85°C  
87°C/W  
IN  
5A  
Ambient Temperature  
(1)  
Junction Temperature (T )  
+150°C  
SO-8 Thermal Resistance (Θ )  
JA  
J
Storage Temperature (T )  
-65°C to +150°C  
Note:  
S
2
1.The package Θ is measured with the device mounted on 1-in FR-4  
JA  
printed-circuit board with 2-oz. copper in a still air environment with  
T = 25°C. The value may vary depending on user’s specific board  
A
design.  
Electrical Characteristics  
V
= 5V, T = -40°C to +85°C unless otherwise stated. Typical values are at 25°C.  
IN  
A
Symbol  
Parameter  
Conditions  
Min.  
Typ.  
Max. Units  
V
Supply Voltage  
2.7  
6.0  
V
IN  
I
Supply Current  
Switch on, no load  
Switch off, no load  
380  
1
530  
2
mA  
IN  
V
Undervoltage Lockout Threshold  
Undervoltage Lockout Hysteresis  
Enable Input Voltage  
V
rising  
1.9  
2.0  
2.3  
2.68  
V
mV  
V
UV  
IN  
V
300  
UVHYS  
V
Enable Input Low Voltage  
Enable Input High Voltage  
0.8  
EN  
V
R
Enable Input Voltage Hysteresis  
Enable Input Current  
400  
mV  
µA  
ENHYS  
I
V
= 4.5V  
1
EN  
DS(ON)  
IN  
Switch On Resistance  
V
V
= 4.5V  
= 2.5V  
35  
48  
45  
60  
mΩ  
IN  
IN  
I
Short-circuit Current  
R
=76.8k, T = +25°C to +85°C  
3.2  
18  
4.0  
24  
4.8  
1
A
µA  
V
LIM  
SET  
A
I
Output Leakage Current  
FLT Output Voltage  
Switch Off  
OFF  
V
I
= 5mA  
0.4  
1
OL  
OL  
FLT Output Leakage Current  
FLT Timeout Period  
µA  
ms  
t
I
to FLT assertion,  
30  
FLT  
LIM  
T = +25°C to +85°C  
A
t
Output Turn-on Delay  
Output Turn-off Delay  
Output Rise-time  
R = 10, C = 1µF  
750  
43  
µs  
µs  
µs  
µs  
ON  
L
L
t
R = 10, C = 1µF  
L L  
OFF  
t
R = 10, C = 1µF  
460  
15  
r
L
L
t
Output Fall-time  
R = 10, C = 1µF  
L L  
f
Rev. 1.3 August 2008  
www.aosmd.com  
Page 3 of 12  
AOZ1300  
Typical Performance Characteristics  
Supply Current vs. Temperature  
Enable Input Threshold (Falling) vs. Temperature  
1.60  
500  
5.5V  
450  
400  
350  
300  
1.50  
1.40  
1.30  
1.20  
1.10  
1.00  
0.90  
0.80  
5.5V  
3.6V  
250  
3.6V  
2.5V  
200  
2.5V  
150  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
Temperature (°C)  
Temperature (°C)  
Enable Input Threshold (Rising) vs. Temperature  
2.00  
Output Leakage Current vs. Temperature  
60  
50  
40  
30  
20  
10  
0
1.90  
1.80  
1.70  
1.60  
1.50  
1.40  
1.30  
1.20  
1.10  
1.00  
5.5V  
3.6V  
2.5V, 3.6V, 5.5V  
2.5V  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
Temperature (C)  
Temperature (C)  
On Resistenace vs. Temperature  
UVLO Threshold vs. Temperature  
2.35  
2.30  
2.25  
2.20  
2.15  
2.10  
2.05  
2.00  
65  
60  
55  
50  
45  
40  
35  
30  
25  
20  
UVLO+  
2.5V  
3.6V  
5.5V  
UVLO-  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
Temperature (°C)  
Temperature (°C)  
Turn-On Delay vs. Temperature  
Fault Delay vs. Temperature  
1.50  
1.40  
1.30  
1.20  
1.10  
1.00  
0.90  
0.80  
0.70  
27  
26  
25  
24  
23  
22  
21  
20  
2.5V  
3.6V  
5.0V  
3.6V  
5.5V  
5.5V  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
Temperature (°C)  
Temperature (°C)  
Rev. 1.3 August 2008  
www.aosmd.com  
Page 4 of 12  
AOZ1300  
Turn-On  
Turn-Off  
EN  
5V/div  
EN  
5V/div  
VOUT  
2V/div  
VOUT  
2V/div  
IOUT  
1A/div  
IOUT  
1A/div  
Time (1ms/div.)  
Time (200µs/div.)  
Output Slew Rate Control  
Short Circuit Response  
EN  
5V/div  
VOUT  
5V/div  
FLT  
5V/div  
FLT  
5V/div  
IOUT  
1A/div  
VOUT  
2V/div  
IOUT  
1A/div  
Time (4ms/div.)  
Time (4ms/div.)  
Latched Output  
UVLO Response  
EN  
5V/div  
VIN  
5V/div  
FLT  
5V/div  
VOUT  
5V/div  
VOUT  
5V/div  
IOUT  
5A/div  
Time (4ms/div.)  
Time (20ms/div.)  
Rev. 1.3 August 2008  
www.aosmd.com  
Page 5 of 12  
AOZ1300  
Timing Diagrams  
50%  
50%  
EN  
90%  
10%  
V
OUT  
t
t
ON  
OFF  
Active-High Enable  
I
LIM  
I
OUT  
FLT  
t
FLT  
Over-current Fault Output Response  
Functional Block Diagram  
IN  
OUT  
Switch  
Gate Driver &  
Slew Rate  
Control  
SLEW  
ISET  
Charge Pump  
Current Limit  
2.3V  
UVLO  
Comparator  
Thermal  
Shutdown  
EN  
FLT  
Fault Delay &  
Latch  
Rev. 1.3 August 2008  
www.aosmd.com  
Page 6 of 12  
AOZ1300  
Detailed Description  
The AOZ1300 is a high-side, current-limited, N-channel  
MOSFET switch optimized for power distribution  
applications which require circuit protection. The device  
operates from 2.7V to 6.0V input voltage and offers  
current limiting and thermal overload protection. The  
device can be programmed for load current up to 4A  
using a single resistor. An open-drain fault output is  
provided to indicate over-current and thermal overload  
fault conditions. The AOZ1300’s soft-start circuitry  
minimizes the inrush current in applications that employ  
highly capacitive loads. The output slew-rate may be  
increased with an external capacitor if longer soft-start  
time is desired. The AOZ1300 features a circuit breaker  
mode that latches the output off upon detecting an over-  
current condition lasting more than 24ms or detecting a  
thermal overload condition. The AOZ1300 features  
reverse current blocking function. Therefore, the output  
voltage can be higher than the input voltage.  
output shuts off, it remains off until the fault load is  
removed from output and the EN input is toggled or the  
input power is recycled. If the fault is still present after EN  
has been cycled, the AOZ1300 will again shut off all  
power to the load after 24ms.  
Thermal Overload Protection  
The thermal overload protection of AOZ1300 is engaged  
to protect the device from damage should the die  
temperature exceeds safe margins due to a short circuit,  
extreme loading or heating from external sources.  
Thermal overload protection sets a fault latch and shuts  
off the internal MOSFET and asserts the FLT output if the  
junction temperature exceeds +120°C.The AOZ1300 can  
be re-enabled by toggling EN pin or cycling the input  
supply after the die temperature drops below +110°C.  
Fault Indicator  
The FLT pin is an open drain output that is asserted low  
when either an over-current, short-circuit or thermal  
overload condition occurs. To prevent false alarm, the  
AOZ1300 implements a 24ms fault blanking time for  
over-current and short-circuit fault conditions. The FLT  
pin becomes high impedance when the fault conditions  
are removed. A 100kpull-up resistor must be  
Enable  
The EN pin is the ON/OFF control for the output switch.  
It is an active-high input. The EN pin is active after V is  
above the UVLO threshold of 2.3V. Conversely, the  
Enable will be de-activated if the V falls below the  
UVLO of 2.0V. The EN pin must be driven to a logic high  
or logic low state to guarantee operation. While disabled,  
the AOZ1300 only draws about 1µA supply current. The  
EN is a high impedance input with an ESD protection  
diode to ground and should not be forced below ground.  
This input level is compatible with most microcontroller  
outputs and other logic families.  
IN  
IN  
connected between FLT to V to provide a logic signal.  
IN  
Slew Rate Control  
The output voltage rise time is controlled to a minimum of  
400µs and is controlled by an internal slew-rate limiting  
circuit. The slew-rate can be increased by placing a  
capacitor between SLEW and ground. As a result, longer  
rise times can be achieved for specific applications. The  
slew rate is independent from the load. Please see Slew  
Rate Setting section for detailed information.  
Under-Voltage Lockout (UVLO)  
The under-voltage lockout (UVLO) circuit of AOZ1300  
monitors the input voltage and prevents the output  
MOSFET from turning on until V exceeds 2.3V. The  
IN  
AOZ1300 will trigger a fault condition and shut down  
Applications Information  
the device when V falls below 2.0V.  
IN  
Input and Output Capacitor Selection  
Over-Current and Short-Circuit Protection  
The input capacitor prevents large voltage transients  
from appearing at the input, and provides the instanta-  
neous current needed each time the switch turns on  
and to limit input voltage droop. Also it is to prevent  
high-frequency noise on the power line from passing  
through the output of the power side. The choice of the  
input capacitor is based on its ripple current and voltage  
ratings rather than its capacitor value.The input capacitor  
should be a low ESR type and located as close to the  
The AOZ1300 is designed to shut off all power to the load  
when the output current exceeds the limit for more than  
the fault blanking period. In the event of an output short  
circuit the current through the switch is limited by an  
internal current-limiting amplifier. The current-limit circuit  
employs a current- sensing algorithm that uses the  
on-state resistance of the high-side MOSFET as a  
current-sensing element. If the current-sense voltage is  
above the current-limit threshold, the AOZ1300 will turn  
off the internal MOSFET. The AOZ1300 has a very fast  
short-circuit response time, nominally 25µs. Once the  
V
pin as possible. A 0.1µF 6.3V ceramic cap is  
IN  
recommended. However, higher capacitor values further  
reduce the voltage drop at the input.  
Rev. 1.3 August 2008  
www.aosmd.com  
Page 7 of 12  
AOZ1300  
The output capacitor acts in a similar way. A small 0.1µF  
capacitor prevents high-frequency noise from going into  
the system. Also, the output capacitor has to supply  
enough current for a large load that it may encounter  
during system transients. This bulk capacitor must be  
large enough to supply fast transient load in order to  
prevent the output from dropping.  
Current Limit Setting  
The AOZ1300 features internal current-limiting circuitry  
with a maximum programmable value of 4.0A. This  
current limit remains in effect throughout the input  
supply-voltage range. The current limit is program by  
using external resistor connected to the ISET pin. The  
current-limit adjustment resistor range is from 70kto  
600k.  
Current Limit vs. Rset @ 5.5V  
Current Limit vs. Rset @ 3.6V  
600  
600  
500  
400  
300  
200  
100  
0
500  
400  
300  
200  
100  
0
0.5  
1.0  
1.5  
2.0  
2.5  
3.0  
3.5  
4.0  
0.5  
1.0  
1.5  
2.0  
2.5  
3.0  
3.5  
4.0  
Current Limit (A)  
Current Limit (A)  
Current Limit vs. Rset @ 2.5V  
600  
500  
400  
300  
200  
100  
0
0.5  
1.0  
1.5  
2.0  
2.5  
3.0  
3.5  
4.0  
Current Limit (A)  
Slew Rate Setting  
capacitor requires a 6.3V rating or greater.The capacitive  
range is 0.001µF to 0.1µF. Please see graph for Output  
Slew Rate Adjustment vs. Capacitance.  
Slew rate is set by changing the capacitor value on the  
Slew pin of the device. A capacitor connected between  
this pin and ground will reduce the output slew-rate. The  
Output Slew Rate Adjustment  
Output Slew Rate Adjustment  
4.00  
80.000  
3.50  
70.000  
60.000  
5.5V  
3.00  
5.5V  
2.50  
50.000  
3.6V  
3.6V  
2.00  
1.50  
40.000  
2.5V  
30.000  
2.5V  
1.00  
0.50  
0.00  
20.000  
10.000  
0.000  
0
0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1  
0
1
2
3
4
5
Capacitance (nF)  
Capacitance (µF)  
Rev. 1.3 August 2008  
www.aosmd.com  
Page 8 of 12  
AOZ1300  
Power Dissipation Calculation  
Calculate the power dissipation for normal load condition  
using the following equation:  
2
P = R x (I )  
OUT  
D
ON  
The worst case power dissipation occurs when the load  
current hits the current limit due to over-current or short  
circuit faults. The power dissipation under these condi-  
tions can be calculated using the following equation:  
P = (V – V  
) x I  
LIMIT  
D
IN  
OUT  
PCB Layout Guidelines  
Silk Screen Top  
Proximity of passive devices and adequate power and  
ground planes are critical for reliable operation of the  
circuit. In general, use the top layer for the high current  
connections and the bottom or inner layer for the quiet  
connections such as GND. The power traces must be  
as short and wide as possible, because of large current.  
Long metal traces and component leads may cause  
unwanted parasitic inductance and capacitance. In order  
to achieve the best performance special care has to be  
taken for proper grounding. A good practice is always the  
use of a separate ground plane or at least a single point  
ground structure. It is recommended to use a PCB with at  
least two sides. It is very important to place the input and  
output capacitor as close as possible to the pin of the  
device.  
Top Layer  
Bottom Layer  
Rev. 1.3 August 2008  
www.aosmd.com  
Page 9 of 12  
AOZ1300  
Package Dimensions, SO-8L  
D
Gauge Plane  
Seating Plane  
e
0.25  
8
L
E
E1  
h x 45°  
1
C
θ
7° (4x)  
A2  
A
0.1  
A1  
b
Dimensions in millimeters  
Dimensions in inches  
Symbols Min. Nom. Max.  
Symbols Min.  
Nom. Max.  
0.053 0.065 0.069  
0.004 0.010  
0.049 0.059 0.065  
2.20  
A
A1  
A2  
b
1.35  
0.10  
1.25  
0.31  
0.17  
4.80  
3.80  
1.65  
1.75  
0.25  
1.65  
0.51  
0.25  
5.00  
4.00  
A
A1  
A2  
b
1.50  
0.012  
0.007  
0.020  
0.010  
c
c
5.74  
D
E1  
e
4.90  
3.90  
1.27 BSC  
6.00  
D
E1  
e
0.189 0.193 0.197  
0.150 0.154 0.157  
0.050 BSC  
1.27  
E
5.80  
0.25  
0.40  
0°  
6.20  
0.50  
1.27  
8°  
E
0.228 0.236 0.244  
h
h
0.010  
0.016  
0°  
0.020  
0.050  
8°  
L
L
0.80  
θ
θ
Unit: mm  
Notes:  
1. All dimensions are in millimeters.  
2. Dimensions are inclusive of plating  
3. Package body sizes exclude mold flash and gate burrs. Mold flash at the non-lead sides should be less than 6 mils.  
4. Dimension L is measured in gauge plane.  
5. Controlling dimension is millimeter, converted inch dimensions are not necessarily exact.  
Rev. 1.3 August 2008  
www.aosmd.com  
Page 10 of 12  
AOZ1300  
Tape and Reel Dimensions, SO-8L  
SO-8 Carrier Tape  
P1  
P2  
See Note 3  
D1  
T
See Note 5  
E1  
E2  
E
See Note 3  
B0  
K0  
D0  
P0  
A0  
Feeding Direction  
Unit: mm  
Package  
A0  
B0  
K0  
D0  
D1  
E
E1  
E2  
P0  
P1  
P2  
T
SO-8  
6.40  
5.20  
2.10  
1.60  
1.50  
12.00 1.75  
5.50  
8.00  
4.00  
2.00  
0.25  
(12mm) ±0.10 ±0.10 ±0.10 ±0.10 ±0.10 ±0.10 ±0.10 ±0.10 ±0.10 ±0.10 ±0.10 ±0.10  
SO-8 Reel  
W1  
S
G
V
N
K
M
R
H
W
Tape Size Reel Size  
M
N
W
W1  
ø330.00 ø97.00 13.00 17.40  
H
K
S
G
R
V
ø13.00  
10.60  
2.00  
12mm  
ø330  
±0.50  
±0.10 ±0.30 ±1.00  
+0.50/-0.20  
±0.50  
SO-8 Tape  
Leader/Trailer  
& Orientation  
Trailer Tape  
300mm min. or  
75 empty pockets  
Components Tape  
Orientation in Pocket  
Leader Tape  
500mm min. or  
125 empty pockets  
Rev. 1.3 August 2008  
www.aosmd.com  
Page 11 of 12  
AOZ1300  
Package Marking  
Z1300AI  
FAYWLT  
Part Number Code  
Underscore Denotes Green Product  
Assembly Lot Code  
Fab & Assembly Location  
Year & Week Code  
Rev. 1.3 August 2008  
www.aosmd.com  
Page 12 of 12  

相关型号:

AOZ1300AI

Programmable 4A Power Distribution Switch
AOS

AOZ1300AIL

Programmable 4A Power Distribution Switch
AOS

AOZ1310

Single Channel USB Switch
AOS

AOZ1312

Single Channel USB Switch
AOS

AOZ1320

Load Switch with Controlled Slew Rate
AOS

AOZ1320CI-01

Load Switch with Controlled Slew Rate
AOS

AOZ1320CI-02

Load Switch with Controlled Slew Rate
AOS

AOZ1320CI-03

Load Switch with Controlled Slew Rate
AOS

AOZ1320CI-04

Load Switch with Controlled Slew Rate
AOS

AOZ1320CI-05

Load Switch with Controlled Slew Rate
AOS

AOZ1320CI-06

Load Switch with Controlled Slew Rate
AOS

AOZ1320CI-07

Load Switch with Controlled Slew Rate
AOS