D10 Expert Series with Bar Graph Display
and Discrete Output
Datasheet
Advanced sensor with dual displays for use with plastic fiber optics
•
Easy-to-read 8-segment light bar indicator for teach and signal strength
readout, plus indicators for continuous readout of operating status (user
configuration)
•
•
•
Easy-to-set automatic Expert-style configuration options include Static and
Dynamic TEACH, and Window SET, plus manual adjustment for fine tuning
Smart gain-control algorithm to maximize performance in low-contrast
applications
Fast 500-microsecond sensing response with improved crosstalk avoidance
routine (for two sensors) in Normal mode
•
•
•
Selectable high-speed (HS) mode option for 200-µs response
Extreme configuration flexibility via push buttons or a remote input wire
Easy selection of Light/Dark Operate (LO/DO), 30 ms pulse stretcher (OFF-
delay), and response speed, via push buttons or a remote input wire
•
Models available with visible red (680 nm) or visible green (525 nm) sensing
beam
•
•
Sleek, ultra-slim 10 mm housing, mounts to a standard 35 mm DIN rail
Models with bussable power provide simplified wiring of up to 16 sensors and
feature improved temperature compensation for side-by-side mounting
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
Models
1
Red Beam Models
D10BFP
Green Beam Models
D10BFPG
Description
Cable
Outputs
2 m (6.5 ft) Cable
6-pin Pico-style QD
Standard sensor
Bipolar NPN/PNP
D10BFPQ
D10BFPGQ
Models with Bussable Power
D10B5FP
-
-
-
Main unit
Sub-unit
2 m (6.5 ft) Cable
2 m (6.5 ft) Cable
2 m (6.5 ft) Cable
Bipolar NPN/PNP
Single PNP
D10B2PFP
D10B2NFP
Single NPN
Overview
™
The D10 Expert is an easy-to-use, DIN-rail-mountable fiber optic sensor. It provides high-performance sensing in low-
contrast applications. Configuration options include Setup mode plus Static and Dynamic TEACH, and Window Set options,
in addition to manual fine adjustment, remote programming, and security push button lockout.
1
To order the 9 m (30 ft) cable model, add the suffix "W/30" to the cabled model number. For example, D10xFP W/30. Models
with a quick disconnect require a mating cordset. See Accessories.
Original Document
117830 Rev. G
14 November 2016
117830
™
D10 Expert Series with Bar Graph Display and Discrete Output
Power ON LED (green)
Output LED (yellow)
The sensor’s compact housing has a large, easy-to-see bar
graph display plus bright LEDs for easy programming and status
monitoring during operation.
Bar graph display (red)
Switching threshold
Configuration status
LEDs (green)
Standard models have bipolar outputs, one each NPN and PNP.
Main units with bussable power have the same bipolar outputs;
sub-units feature a single discrete output, either NPN or PNP.
Models with bussable power are designed for use in machines
and other applications where multiple sensors will be grouped
tightly. They feature increased temperature compensation
compared with standard models and reduce the amount of
wiring necessary for such applications. An accessory clamp is
available to secure a bank of connected sensors together on a
DIN rail (see Accessories on page 13).
Configuration push buttons
Bussable power input
port (cap supplied for
unused port)
Bussable power output
port (cap supplied for
unused port)
Figure 1. Features
Sensor Configuration
Sensor configuration is accomplished via TEACH, Set, and Setup modes. After the sensing parameters are defined (using
either TEACH or Set mode), Setup mode may be used to enable the delay, to change the light/dark operate status, or to
select the highspeed response option (HS). Manual Adjust may be used to fine-tune the thresholds. Two push buttons,
Dynamic (+) and Static (−), or the remote wire, may be used to access and set the sensing parameters.
Sensor sensitivity may be configured using any of three methods. A single switching threshold may be achieved using
either Dynamic (on-the-fly) or Static TEACH; or Window SET may be used to define a sensing window, centered on a
single sensing condition.
Remote Configuration
The remote configuration function may be used to configure the sensor remotely or to disable the push buttons for
security. Connect the gray wire of the sensor to ground (0V dc), with a remote programming switch connected between
them. Pulse the remote line according to the diagrams in the configuration procedures. The duration of the individual
pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds
Returning to RUN Mode
Some TEACH, Set, and Setup modes may be exited either after the 60-second timeout, or by exiting the process:
•
In Static TEACH or Window Set mode, press and hold the Static (−) button (or hold the remote line) for 2 seconds.
The sensor returns to Run mode without saving any new settings.
•
In Setup mode, press and hold both the Static (−) and Dynamic (+) buttons (or hold the remote line) for 2
seconds. The sensor returns to Run mode and saves the current setting.
2
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 117830 Rev. G
™
D10 Expert Series with Bar Graph Display and Discrete Output
Two-Point Static TEACH (Threshold)
2nd Taught
Condition
1st Taught
Condition
•
•
Establishes a single switching threshold
Threshold position is adjustable using “+” and “-” buttons (see
Manual Adjust)
Sensor positions
threshold midway
between taught conditions
Static TEACH is the traditional setup method, used when two
conditions can be presented by the user. The sensor locates a single
sensing threshold (the switchpoint) midway between the two taught
conditions, with the Output ON condition on one side, and the Output
OFF condition on the other.
Output OFF
Output ON
The first condition taught is the ON condition. The Output ON and OFF
conditions can be reversed by changing Light/Dark Operate status in
Setup mode (see Setup Mode on page 8 ).
Darkest
(no signal)
Position
adjusted by
Manual Adjust
Most Light
(saturated
signal)
Static TEACH and Manual Adjust. Using Manual Adjust with Static
TEACH moves the switching threshold. The lighted LED on the bar
graph will move to exhibit the received signal, relative to the
switchpoint.
Figure 2. Static TEACH (Light Operate shown)
Bar Graph LED Following TEACH
Relative Signal Difference / Recommendation
Excellent: Very stable operation
6 to 8
4 to 5
2 to 3
1
Good: Minor sensing variables may affect sensing reliability
Low: Minor sensing variables may affect sensing reliability
Unreliable: Consider an alternate sensing scheme
1. Access the TEACH Mode.
Method
Action
Result
•
•
•
Power LED: OFF
Output LED: ON
Status LEDs: LO & DO
alternately flash
Press and hold the Static button > 2
seconds.
2
Push Button
3
Remote Input
No action is required; the sensor is ready for 1st TEACH condition.
•
Bar graph: OFF
2. TEACH the Output ON condition.
Method
Action
Result
a. Present the Output ON condition.
b. Click the Static button.
•
•
•
Power LED: OFF
Output LED: Flash, then OFF
Status LEDs: LO & DO
alternately flash
Bar graph: OFF
Push Button
a. Present the Output ON condition.
b. Single-pulse the remote line.
T
•
Remote Input
3. TEACH the Output OFF condition.
Method
Action
Result
TEACH Accepted
a. Present the Output OFF condition.
b. Click the Static button.
•
•
Power LED: ON
Push Button
Bar graph: One LED flashes to
show relative contrast (good
signal difference shown; see
table above)
Sensor returns to Run mode.
TEACH Unacceptable
a. Present the Output OFF condition.
b. Single-pulse the remote line.
T
Remote Input
•
•
Power LED: OFF
Bar graph: #1, 3, 5, 7
alternately flash to show failure
Sensor returns to the "TEACH Output ON
condition".
2
3
0.04 seconds ≤ "Click" ≤ 0.8 seconds
0.04 seconds ≤ T ≤ 0.8 seconds
P/N 117830 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
3
™
D10 Expert Series with Bar Graph Display and Discrete Output
Dynamic TEACH and Adaptive Thresholds
Darkest Taught
Condition
Lightest Taught
Condition
•
•
•
Teach on-the-fly
Establishes a single switching threshold
Threshold position is adjustable using “+” and “-” buttons
(Manual Adjust)
Sensor positions
threshold midway
between taught conditions
Dynamic TEACH is best used when a machine or process may not
be stopped for teaching. It programs the sensor during actual
sensing conditions, taking multiple samples of the light and dark
conditions and automatically setting the threshold at the optimum
level.
Output OFF
Output ON
Dynamic TEACH activates the sensor’s adaptive threshold system,
which continuously tracks minimum and maximum signal levels,
and automatically maintains centering of the switchpoint between
the light and dark conditions. The adaptive threshold system
remains in effect during Run mode. The adaptive routine saves to
non-volatile memory at least once per hour.
Darkest
(no signal)
Position
adjusted by
Manual Adjust
Most Light
(saturated
signal)
Figure 3. Dynamic TEACH (Light Operate shown)
When Dynamic TEACH mode is used, the output ON state (Light or Dark Operate) remains as it was last programmed. To
change the output ON state, use Setup mode.
Dynamic TEACH and Manual Adjust
The switchpoint may be adjusted (fine-tuned) whenever the sensor is in Run mode by clicking the “+” and “-” buttons.
However, when a manual adjustment is made, the adaptive threshold system is disabled (cancelled).
Bar Graph LED Following TEACH
Relative Signal Difference / Recommendation
Excellent: Very stable operation
6 to 8
4 to 5
2 to 3
1
Good: Minor sensing variables may affect sensing reliability
Low: Minor sensing variables may affect sensing reliability
Unreliable: Consider an alternate sensing scheme
1. Access the Dynamic TEACH Mode.
Method
Action
Result
Press and hold the Dynamic push button > 2
seconds.
4
•
•
•
Power LED: OFF
Output LED: OFF
Bar graph: LO & DO alternately
flash
Push Button
5
Remote Input
Hold the remote line low (to ground) > 2 seconds.
2. TEACH the sensing condition.
Method
Action
Result
Continue to hold push button and present Output
ON and OFF conditions.
•
•
•
Power LED: OFF
Output LED: OFF
Bar graph: LO & DO alternately
flash
Push Button
Continue to hold remote line low (to ground) and
present Output ON and OFF conditions.
Remote Input
3. Return to RUN Mode.
Method
Action
Result
TEACH Accepted
Push Button
Release the push button.
•
•
Power LED: ON
Bar graph: One LED flashes to
show relative contrast (good
signal difference shown; see
table above)
Sensor returns to Run mode with new
settings.
TEACH Not Accepted
Remote Input
Release the remote line/switch
•
•
Power LED: OFF
Bar graph: #1, 3, 5, 7
alternately flash to show failure
Sensor returns to Run mode without
changing settings
4
5
0.04 seconds ≤ "Click" ≤ 0.8 seconds
0.04 seconds ≤ T ≤ 0.8 seconds
4
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 117830 Rev. G
™
D10 Expert Series with Bar Graph Display and Discrete Output
Single-Point Window Set
•
•
•
Sets a single ON condition that extends 12.5% above and below the taught condition
All other conditions (lighter or darker) result in OFF output
Sensing window size (sensitivity) is adjustable using “+” and “-” buttons (see Manual Adjust on page 8)
Window Set is most useful when a product may not always appear in
the same place, or when other signals may appear. Window Set
designates a sensing window, with the Output ON condition inside
the window, and the Output OFF conditions outside the window. The
sensor accepts a single sensing condition, and adds switching
thresholds above and below that condition to create a sensing
window. Output ON and OFF conditions can be reversed by changing
Light/Dark Operate status in Setup mode.
Sensing window size
adjusted by
Manual Adjust
Sensor positions
window thresholds
12.5% from the
presented condition
Window Set and Manual Adjust
Output OFF
Output ON
Output OFF
Using Manual Adjust with Window Set expands or contracts the size
of the window. The lighted LEDs on the light bar separate to a
greater or lesser extent to exhibit the relative sensing window size.
Darkest
(no signal)
Condition
Presented
Most Light
(saturated
signal)
Figure 4. Single-Point Window SET (Light Operate
shown)
1. Access the SET Mode.
Method
Action
Result
•
•
•
•
Power LED: OFF
Output LED: ON (Push Button)
Output LED: OFF (Remote)
Status LEDs: LO & DO flash
alternately
6
Push Button
Press and hold the Static button > 2 seconds.
T
7
Remote Input
Single-pulse the remote line.
2. SET the sensing condition.
Method
Action
Result
Window Accepted
a. Present the sensing condition.
b. Double-click the Static button.
•
•
Power LED: ON
Push Button
Bar graph: 2 indicators flash
together to show Window
accepted
Sensor returns to Run mode with the new
settings.
T
T
Window Not Accepted
a. Present sensing the condition.
b. Double-pulse the remote line.
Remote Input
•
•
Power LED: OFF
Bar graph: #1, 3, 5, 7 flash to
show failure
T
Sensor returns to the "SET Sensing
condition".
6
7
0.04 seconds ≤ "Click" ≤ 0.8 seconds
0.04 seconds ≤ T ≤ 0.8 seconds
P/N 117830 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
5
™
D10 Expert Series with Bar Graph Display and Discrete Output
Single-Point Light Set
•
•
Sets a threshold 6.25% below the taught condition.
Any condition darker than the threshold condition causes the
output to change state
Threshold position is adjustable using the “+” and “-” buttons
(see Manual Adjust on page 8)
Recommended for applications where only one condition is
known, for example a stable light background with varying
darker targets
Threshold position
adjusted by
Manual Adjust
•
•
Sensor positions the
threshold slightly below
the presented condition
Output OFF
Output ON
A single sensing condition is presented, and the sensor positions a
threshold 6.25% below the presented condition. When a condition
darker than the threshold is sensed, the output either turns ON or OFF,
depending on the Light/Dark Operate setting (see Setup Mode on page
8).
Darkest
(no signal)
Condition
Presented
Most Light
(saturated
signal)
Light SET and Light/Dark Operate Selection
Figure 5. Single-Point Light Set (Light Operate shown)
In Light Operate mode, Light Set teaches the Output ON condition. In
Dark Operate mode, Light Set teaches the Output OFF condition.
1. Access the SET Mode.
Method
Action
Result
•
•
•
•
Power LED: OFF
Output LED: ON (push button)
OFF (remote line)
Static LEDs: LO & DO
alternately flash
8
Push Button
Press and hold the Static button > 2 seconds.
T
9
Remote Input
Single-pulse the remote line.
2. SET the sensing condition.
Method
Action
Result
Threshold condition accepted
a. Present the sensing condition.
Push Button
•
•
•
•
Power LED: ON
Output LED: ON (push button)
OFF (remote line)
Bar graph: 4 indicators flash
together
b. Four-click the Static push button.
Sensor returns to Run mode with the new
settings.
Threshold condition not accepted
T
T
T
T
a. Present the sensing condition.
b. Four-pulse the remote line.
•
•
•
•
Power LED: ON
Output LED: ON (push button)
OFF (remote line)
Remote Input
T
T
T
Bar graph: #1, 3, 5, 7
alternately flash to show failure
Sensor returns to the "SET Sensing
Condition".
8
9
0.04 seconds ≤ "Click" ≤ 0.8 seconds
0.04 seconds ≤ T ≤ 0.8 seconds
6
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 117830 Rev. G
™
D10 Expert Series with Bar Graph Display and Discrete Output
Single-Point Dark Set
Threshold position
adjusted by
Manual Adjust
•
•
Sets a threshold 6.25% above the taught condition
Any condition lighter than the threshold condition causes the
output to change state
•
•
Threshold position is adjustable using the “+” and “-” buttons
(see Manual Adjust on page 8)
Recommended for applications where only one condition is
known, for example a stable dark background with varying
lighter targets
Sensor positions
threshold slightly above
the presented condition
Output OFF
Output ON
A single sensing condition is presented, and the sensor positions a
threshold 6.25% above the taught condition. When a condition lighter
than the threshold is sensed, the output either turns ON or OFF,
depending on the Light/Dark Operate setting (see Setup Mode on page
8).
Condition
Presented
Darkest
(no signal)
Most Light
(saturated
signal)
Dark Set and Light/Dark Operate Selection
Figure 6. Single-Point Dark Set (Light Operate
shown)
In Light Operate mode, Dark Set teaches the Output OFF condition. In
Dark Operate mode, Dark Set teaches the Output ON condition.
1. Access Set Mode
Method
Action
Result
•
•
•
•
Power LED: OFF
Output LED: ON (push button)
OFF (remote line)
Static LEDs: LO & DO
alternately flash
10
Push Button
Press and hold the Static button > 2 seconds.
T
11
Remote Input
Single-pulse the remote line.
2. Set the sensing condition.
Method
Action
Result
Threshold Condition Accepted
a. Present the sensing condition.
b. Five-click the Static button.
•
•
•
•
Power LED: ON
Output LED: ON (push button)
OFF (remote line)
Bar graph: 4 indicators flash
together
Push Button
The sensor returns to Run mode with the
new settings.
Threshold Condition Not Accepted
T
T
T
T
T
a. Present the sensing condition.
b. Five-pulse the remote line.
•
•
•
•
Power LED: ON
Output LED: ON (push button)
OFF (remote line)
Bar graph: #1, 3, 5, 7 flash to
show failure
Remote Input
T
T
T
T
The sensor returns to the "SET Sensing
Condition".
10
11
0.04 seconds ≤ "Click" ≤ 0.8 seconds
0.04 seconds ≤ T ≤ 0.8 seconds
P/N 117830 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
7
™
D10 Expert Series with Bar Graph Display and Discrete Output
Setup Mode
Use Setup mode to change sensor output response for:
•
•
•
Light or Dark operate
30-millisecond pulse stretcher (OFF-delay), if required
200 μs high-speed response
Setup status
indicators
If Setup mode configuration is interrupted and remains inactive
for 60 seconds, the sensor returns to Run mode with the most
recent settings (i.e., exits and saves current selection).
Setup mode operates in the background, while the outputs are
active; changes are updated instantly.
Press and hold both
buttons for more than
2 seconds to access
Setup Mode
1. Access the Setup Mode.
Method
Action
Result
12
•
•
•
Power LED: OFF
Output LED: remains active
Icon continue to display current
setup
Static LEDs: OFF
Push Button
Press and hold both push buttons > 2 seconds.
T
T
13
Remote Input
Double-pulse the remote line.
•
T
2. Select the setting combination.
Method
Action
Result
The sensor toggles through eight setting
combinations, in the following order:
or
Click either push button until the LEDs show
desired settings.
Push Button
LO - Normal Speed - No Delay
(default)
DO - Normal Speed - No Delay
LO - High Speed - No Delay
DO - High Speed - No Delay
LO - Normal Speed - Delay
DO - Normal Speed - Delay
LO - High Speed - Delay
Pulse the remote line until the LEDs show desired
settings.
NOTE: Double-pulsing
the remote line will
cause the setting to
back up one step.
Remote Input
DO - High Speed - Delay
3. Return to Run Mode.
Method
Action
Result
Push Button
Press and hold both push buttons > 2 seconds.
Hold remote the line low > 2 seconds.
Power LED: ON
The sensor returns to RUN mode with the
new settings.
2 seconds
Remote Input
Manual Adjust
Manual Adjust is used during Run mode and is accomplished using the push buttons only. Its behavior depends on whether
a switching threshold or a sensing window is used.
Switching Threshold:
•
•
Fine-tunes sensing sensitivity
Press “+” to increase; press “-” to decrease
Sensing Window:
12
13
0.04 seconds ≤ "Click" ≤ 0.8 seconds
0.04 seconds ≤ T ≤ 0.8 seconds
8
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 117830 Rev. G
™
D10 Expert Series with Bar Graph Display and Discrete Output
•
•
Adjusts sensing window size (tolerance) for the single-point target condition
Press “+” to increase; press “-” to decrease
The lighted bar graph LEDs move to reflect the increase or decrease.
Enabling or Disabling the Push Button
In addition to its programming function, the remote line may be used to disable the push buttons for security. Disabling
the push buttons prevents undesired tampering with the sensor configuration settings.
1. Connect the sensor’s gray wire.
2. Four-pulse the remote line to enable or disable the push button.
The sensor toggles between enable and disable settings and returns to RUN mode.
Wiring Diagrams
Standard Models and Main Unit
Installing Fibers
1 - Brown
2 - White
3 - Blue
4 - Black
5 - Gray
1
+
10-30V dc Standard Models
12-30V dc Bussable Power Models
3
−
Slides up to
release fibers
2
150 mA max. load
6 - Pink (not used)
Load
Load
4
5
The QD hookup is functionally
identical. The pink wire is not used.
Plastic fiber
emitter port
Remote Teach
Plastic fiber
receiver port
Sub-Units
NPN
PNP
12-30V dc
Connection
From Main
Unit Bus
12-30V dc
Connection
From Main
Unit Bus
+
+
−
−
4
5
4
5
Load
Load
Remote Teach
Remote Teach
P/N 117830 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
9
™
D10 Expert Series with Bar Graph Display and Discrete Output
Specifications
Sensing Beam
Output Protection
Standard sensors: 660 nm visible red or 525 nm visible green,
depending on model
Protected against output short-circuit, continuous overload, transient
over-voltages, and false pulse on power-up
Models with bussable power: 660 nm visible red
Output Response Time
Supply Voltage
500 microseconds (normal mode) or 200 microseconds (high-speed
mode)
Standard sensors: 10 to 30 V dc (10% maximum ripple) at less than
45 mA exclusive of load
Models with bussable power: 12 to 30 V dc (10% maximum ripple) at
less than 45 mA exclusive of load
Repeatability
100 microseconds (normal mode) or 66 microseconds (high-speed
mode)
Supply Protection Circuitry
Adjustments
Protected against reverse polarity, over voltage, and transient voltage
2 push buttons and remote wire
Delay at Power Up
•
Expert-style configuration (Static and Dynamic TEACH, and
Window Set)
Manually adjust (+/–) sensitivity (from push buttons only)
LO/DO, OFF-delay, and response speed configurable (from
push buttons or remote wire)
Standard Sensors: 200 milliseconds maximum; outputs do not conduct
during this time
Models with Bussable Power: 850 milliseconds maximum; outputs do
not conduct during this time
•
•
Output Rating (Standard Sensors)
•
Push button lockout (from remote wire only)
Standard Sensors: 150 mA maximum load at 25° C (derate 1 mA per
°C increase)
OFF-state leakage current: < 5 μA at 30 V dc
ON-state saturation voltage: NPN: < 200 mV at 10 mA; 1 V at 150 mA
load; PNP: < 1 V at 10 mA; 1.5 V at 150 mA load
Factory Default Settings: Light Operate, Normal Speed, No Delay
Push-button or remote programming of response time, OFF-delay,
light/dark operate, and display
Indicators
8-segment red bar graph: Light-to-dark signal difference relative to
taught condition (Window Set); Sensing contrast (Static or Dynamic
TEACH)
Green Status Indicators: LO, DO, High Speed (HS), and OFF-Delay
Green LED: Power ON
Output Rating (Models with Bussable Power)
Models with Bussable Power: 100 mA maximum load (derate 1 mA per
°C above 30 °C)
OFF-state leakage current: < 5 μA at 30 V dc
ON-state saturation voltage: NPN: < 1.5 V; PNP: < 2 V
Supply 15 V or more: up to 16 units with 100 mA outputs
Less than 15 V supply (9 m cable): up to 4 units with 100 mA outputs;
up to 8 units with 50 mA outputs
Yellow LED: Output conducting
Construction
Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear
polycarbonate cover
Required Overcurrent Protection
Environmental Rating
IEC IP50, NEMA 1
WARNING: Electrical connections must be
made by qualified personnel in accordance
with local and national electrical codes and
regulations.
Connections
Standard Sensors: PVC-jacketed 2 m or 9 m (6.5 ft or 30 ft) 6-wire
integral cable or integral 6-pin Pico-style quick-disconnect
Models with Bussable Power: Main units: PVC-jacketed 2 m or 9 m
(6.5 ft or 30 ft) 5-wire integral cable; Sub-units: PVC-jacketed 2 m or
9 m (6.5 ft or 30 ft) 2-wire integral cable
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via
Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Operating Conditions
Temperature: −10 °C to +55 °C (+14 °F to +131 °F)
Storage Temperature: −20 °C to +85 °C (−4 °F to +185 °F)
90% at +55 °C maximum relative humidity (non-condensing)
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
Certifications
20
22
24
26
28
30
5.0
3.0
2.0
1.0
0.8
0.5
10
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 117830 Rev. G
™
D10 Expert Series with Bar Graph Display and Discrete Output
Dimensions
10.5 ± 0.2 mm (typ.)
(0.41")
7.6 mm
0.30"
35.9 mm
(1.41")
9.8 mm
(0.39")
Mounting Bracket
(included)
61.3 mm
(2.42")
68.1 mm
(2.68")
All measurements are listed in millimeters [inches], unless noted otherwise.
Included Bracket Dimensions
8.6 mm
(0.34")
M3 Hardware included:
Lock Washer (2)
Flat Washer (2)
Screws (2)
10.0 mm
(0.39")
5.0 mm
(0.20")
5.0 mm (0.20")
2.5 mm (0.10")
2x 3.5 mm
(0.14")
Hex Nuts (2)
35.1 mm
(1.38")
25.4 mm
(1.00")
16.0 mm
(0.63")
15.2 mm
(0.60")
2 x ø3.3 mm (0.13")
2x ø3.2 mm (0.13")
10.0 mm
(0.39")
2x C'sink
ø8.0 mm (0.31")
3.2 mm (0.13") deep
ø4.4 mm (0.18") thru
P/N 117830 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
11
™
D10 Expert Series with Bar Graph Display and Discrete Output
Performance Curves
Red Beam Models
Opposed Mode
Diffuse Mode (Performance based on 90%
reflectance white test card)
10000
1000
1000
100
10
E
X
C
E
X
C
E
S
S
1000
100
1000
100
100
E
E
X
C
E
S
S
E
X
C
E
S
S
S
S
PBT66U
PBT26U
10
PIT26U
G
PIT66U
G
A
I
A
PIT46U
I
PIT16U
10
1
10
1
G
A
I
G
A
I
N
N
PBT46U
1
1
PBT16U
1 mm
(.04")
10 mm
(0.4")
100 mm
(4.0")
1000 mm
(40.0")
1 mm
(.04")
10 mm
(0.4")
100 mm
(4.0")
1000 mm
(40.0")
N
N
DISTANCE
DISTANCE
0.1 mm
(.004")
1 mm
(.04")
10 mm
(0.4")
100 mm
(4.0")
0.1 mm
(.004")
1 mm
(.04")
10 mm
(0.4")
100 mm
(4.0")
1000 mm
(40.0")
DISTANCE
DISTANCE
3.93"
2.95"
100 mm
30 mm
1.18"
300 mm
11.81"
PIT66U
75 mm
50 mm
25 mm
PIT26U
PIT16U
20 mm
10 mm
0.78"
0.39"
0
200 mm
100 mm
7.87"
3.93"
0
15 mm
0.59"
0.39"
1.97"
0.98"
0
10 mm
5 mm
PBT66U
PBT46U
PBT26U
0
0
PIT46U
0.19"
0
0
10 mm
20 mm
30 mm
0.39"
0.78"
1.18"
100 mm
200 mm
300 mm
3.93"
7.87"
11.81"
0
PBT16U
25 mm
50 mm
75 mm
100 mm
0.98"
1.97"
2.95"
5 mm
0.19"
0.39"
0.59"
10 mm
100 mm
0
12 mm
(0.47")
24 mm
(0.94")
36 mm
(1.42")
48 mm
(1.90")
60 mm
(2.36")
0
80 mm 160 mm 240 mm 320 mm 400 mm
3.93"
(3.15")
(6.30")
(9.45") (12.59") (15.74")
0
4 mm
(0.15")
8 mm
(0.31")
12 mm
(0.47")
16 mm
(0.63")
20 mm
(0.78")
0
32 mm
(1.26")
64 mm
(2.52")
96 mm 128 mm 160 mm
(3.78") (5.04") (6.30")
DISTANCE
DISTANCE
DISTANCE
DISTANCE
Green Beam Models
Opposed Mode
Diffuse Mode (Performance based on 90%
reflectance white test card)
1000
1000
1000
100
10
1000
E
X
C
E
S
S
E
X
C
E
S
S
E
X
C
E
X
C
E
S
S
100
10
100
10
100
E
S
S
PBT66U
10
G
G
A
I
G
A
I
G
A
I
PIT66U
PBT26U
A
I
N
PIT26U
PIT46U
PBT46U
N
N
N
PIT16U
1
1
1
1
0.1 mm
(.004")
1 mm
(.04")
10 mm
(0.4")
100 mm
(4.0")
0.1 mm
(.004")
1 mm
(.04")
10 mm
(0.4")
100 mm
(4.0")
1 mm
(.04")
10 mm
(0.4")
100 mm
(4.0")
1000 mm
(40.0")
1 mm
(.04")
10 mm
(0.4")
100 mm
(4.0")
1000 mm
(40.0")
DISTANCE
DISTANCE
DISTANCE
DISTANCE
0.31"
0.23"
2.36"
1.77"
8 mm
60 mm
1.5 mm
0.06"
30 mm
1.18"
PIT26U
PIT66U
6 mm
4 mm
2 mm
45 mm
30 mm
15 mm
0
PBT66U
1.0 mm
0.5 mm
0.04"
0.02"
0
20 mm
10 mm
0.78"
0.39"
0
0.16"
0.08"
0
1.18"
0.59"
0
PBT46U
0
0
PBT26U
0
PIT16U
PIT46U
0.5 mm
1.0 mm
1.5 mm
0.02"
0.04"
0.02"
10 mm
20 mm
30 mm
0.39"
0.78"
1.18"
2 mm
4 mm
6 mm
8 mm
0.08"
0.16"
0.23"
15 mm
30 mm
45 mm
60 mm
0.59"
1.18"
1.77"
0
1 mm
(0.04")
2 mm
(0.08")
3 mm
(0.12")
4 mm
(0.16")
5 mm
(0.19")
6 mm
(0.23")
0
10 mm
(0.39")
20 mm
(0.78")
30 mm
(1.18")
40 mm
(1.57")
50 mm
(1.97")
0.31"
2.36"
0
4 mm
(0.16")
8 mm
(0.31")
12 mm
(0.47")
16 mm
(0.63")
20 mm
(0.78")
0
24 mm
(0.71")
48 mm
(1.42")
72 mm
(2.12")
96 mm 120 mm
(2.83") (3.54")
DISTANCE
DISTANCE
DISTANCE
DISTANCE
12
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 117830 Rev. G
™
D10 Expert Series with Bar Graph Display and Discrete Output
Accessories
Quick Disconnect Cordsets
6-Pin Snap-on M8/Pico-Style Cordsets
Model
Length
Style
Dimensions
Pinout (Female)
PKG6Z-2
2 m (6.5 ft)
32 Typ.
Straight
4
5
3
PKG6Z-9
PKW6Z-2
9 m (30 ft)
2 m (6.5 ft)
ø 9.0
1
6
2
29 Typ.
1 - brown
2 = White
3 = Blue
4 = Black
5 = Gray
6 = Pink
Right-angle
15 Typ.
PKW6Z-9
9 m (30 ft)
ø 10.9
DIN Rail Accessories
SA-DIN-CLAMP
•
•
Pair of metal DIN rail end stops; slide onto DIN rail at either side of the sensor stack
Combination (#2 Phillips, #8 standard slotted) set screw
9.1 mm
(0.63")
9.1 mm
(0.36")
45.0 mm
(1.77")
SA-D10B-CAP
Package of 5 each replacement terminal caps and plugs to cover beginning and end of stack of connected sensors.
P/N 117830 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
13
™
D10 Expert Series with Bar Graph Display and Discrete Output
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp.
will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty
period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION,
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE
OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE
LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER
ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product
previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection
applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval
by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product
specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most
recent version of any documentation, refer to: www.bannerengineering.com.
©
Banner Engineering Corp. All rights reserved
相关型号:
©2020 ICPDF网 联系我们和版权申明