MDU150-4000MG [BEL]
AC-DC Power Factor Correction Module,;型号: | MDU150-4000MG |
厂家: | BEL FUSE INC. |
描述: | AC-DC Power Factor Correction Module, |
文件: | 总8页 (文件大小:1212K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
The innovative MPU products incorporate Power Factor Correction
(PFC) with a low-profile package designed to meet 1U height
constraints. The MPU150-4530G and MPU150-4350G provide high
current +3.3 V and +5 V on a single platform to support mixed-mode,
high-speed digital circuitry. Bel Power Solutions unique dual converter
architecture combines high reliability with exceptional regulation.
All multiple output models feature remote sense on outputs V1 and V2
to provide independent compensation of output cable losses. Other
standard features include independent current sharing on V1 and V2,
thermal shutdown, and remote inhibit. Airflow of 300 linear feet per
minute (LFM) is required to deliver the full power density of 3.0 watts
per cubic inch.
The MDU150 Series provides the same benefits as the MPU150
Series, with nominal 48 volt DC input.
RoHS Compliant
Power Factor Correction (PFC)
Low-profile height fits 1U constraints
Dual main outputs provide 3.3 V and 5 V for mixed mode applications
Single wire current sense on outputs V1 and V2
Remote sense on outputs V1 and V2
Overtemperature, overload, and overvoltage protection
Available with metric or SAE mountings
Greater than 340000 Hours MTBF
MDU150 models have 48 VDC input
Asia-Pacific
Europe, Middle East
North America
+86 755 298 85888
+353 61 225 977
+1 866 513 2839
© 2015 Bel Power Solutions, Inc.
BCD.00603_AA
2
180 W with 300 LFM Forced-Air Cooling
MAXIMUM
OUTPUT
RIPPLE &
NOISE
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
LINE
LOAD
INITIAL SETTING
ACCURACY
MODEL6
REGULATION REGULATION
CURRENT 1
% pk-pk 2
MPU150-S259G
MPU150-S262G
MPU150-S261G
12V
24V
48V
11.6V to 16V
22.8V to 29.2V
45V to 56V
15A 3
7.5A 3
3.75A 3
0.1%
0.1%
0.1%
1%
1%
1%
1%
1%
1%
11.97V to 12.03V
23.95V to 24.05V
47.9V to 48.1V
150 W with 300 LFM Forced-Air Cooling - Isolated V3 and V4 can be used as positive or negative outputs
RIPPLE &
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
LINE
LOAD
INITIAL SETTING
ACCURACY
MODEL6
NOISE
CURRENT 1 REGULATION REGULATION
% pk-pk 2
+3.3V
+5V
3.15V to 3.80V
5.0V to 5.5V
35A
20A
0.6%
0.4%
1.5%
3%
1.5%
1%
3.28V to 3.32V
4.98V to 5.02V
MPU150-3300G
+12V
+5V
Fixed
2A
17.5A
4A
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.8%
0.6%
0.4%
0.4%
0.6%
0.4%
0.4%
0.4%
0.4%
0.6%
0.4%
0.4%
3%
1%
3%
3%
1%
1%
1%
1%
2%
1.5%
1%
1%
1.5%
1%
7%
7%
1%
1.5%
7%
7%
1%
1%
1%
1%
1%
1%
1%
1%
2%
1.5%
1%
1%
1%
1%
1%
1%
1%
1.5%
1%
1%
11.76V to 12.24V
4.98V to 5.02V
11.94V to 12.06V
23.52V to 24.48V
4.98V to 5.02V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
2.49V to 2.51V
3.28V to 3.32V
11.94V to 12.06V
4.98V to 5.0V
5.0V to 5.5V
10.8V to 13.2V
Fixed
MPU150-3524G
MPU150-4000G
+12V
+24V
+5V
2A
30A 4
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
2.25V to 3.0V
3.15V to 3.8V
10.8V to 13.2V
5.0V to 5.5V
3.15V to 3.80V
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
+12V
12V
8A
3A
5V
2A
+2.5V
+3.3V
12V
30A 4
15A 4
4A 5
2A 5
30A 4
15A 4
3A 5
3A 5
30A 4
15A 4
3A 5
3A 5
MPU150-4230G
MPU150-4350G
MPU150-4530G
5V
+3.3V
+5V
3.28V to 3.32V
5.00V to 5.04V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
3.28V to 3.32V
11.94V to 12.06V
11.94V to 12.06V
12V
12V
+5V
+3.3V
12V
12V
NOTES:
1
The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions.
It is recommended that the airflow be applied from the input side of the power supply blowing towards the output.
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
Total power of 180 Watts.
Total current between V1 and V2 is 30A, maximum rating.
Total current between V3 and V4 is 5A, maximum rating.
2
3
4
5
6
Non-G models use lead solder exemption and are not recommended for new designs.
tech.support@psbel.com
3
150 W with 300 LFM Forced-Air Cooling - Isolated V3 and V4 can be used as positive or negative outputs
RIPPLE &
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
LINE
LOAD
INITIAL SETTING
ACCURACY
MODEL6
NOISE
CURRENT 1
REGULATION REGULATION
% pk-pk 2
+3.3V
+5V
3.15V to 3.80V
5.0V to 5.5V
N/A
35A
20A
2A
0.6%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
2%
1.5%
3%
1.5%
1%
1%
1%
1%
1%
1%
2%
1.5%
1%
1%
1%
1%
1%
1%
1%
1.5%
1%
1%
3.28V to 3.32V
4.98V to 5.02V
11.76V to 12.24V
4.98V to 5.02V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
2.49V to 2.51V
3.28V to 3.32V
11.94V to 12.06V
4.98V to 5.0V
MDU150-3300G
+12V
+5V
3%
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
2.25V to 3.0V
3.15V to 3.8V
10.8V to 13.2V
5.0V to 5.5 V
3.15V to 3.8V
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
30A 3
8A
1%
+12V
12V
1%
MDU150-4000G
MDU150-4230G
MDU150-4350G
MDU150-4530G
3A
1%
5V
2A
1%
+2.5V
+3.3V
12V
30A 3
15A 3
3A
2%
1.5%
1%
1.5%
1%
5V
2A
1%
1%
+3.3V
+5V
30A 5
15A 5
3A 4
3A 4
30A 3
15A 3
3A 4
3A 4
1.5%
1%
1.5%
1%
3.28V to 3.32V
5.00V to 5.04V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
3.28V to 3.32V
11.94V to 12.06V
11.94V to 12.06V
12V
7%
7%
12V
7%
7%
+5V
0.4%
0.6%
0.4%
0.4%
1%
+3.3V
12V
1.5%
7%
12V
7%
NOTES:
1
The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions.
It is recommended that the airflow be applied from the input side of the power supply blowing towards the output.
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
Total current between V1 and V2 is 30A, maximum rating.
Total current between V3 and V4 is 5A, maximum rating.
Total current between V1 and V2 is 40A, maximum rating.
2
3
4
5
6
Non-G models use lead solder exemption
OPTIONS
SUFFIXES TO ADD TO PART NUMBER
Metric Mounting
Add “M” as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts.
RoHS lead solder exempt
No RoHS suffix character required.
RoHS compliant for all 6 substances
Add “G” as the last character of the part number.
tech.support@psbel.com
4
PARAMETER
CONDITIONS / DESCRIPTION
Continuous input range.
AC input.
MIN
85
NOM
MAX
264
63
UNITS
VAC
Hz
Input Voltage - AC
Input Frequency
47
MPU150-4350G
All other models
17.5
20
Hold-up Time
After last AC line peak at 150 watts.
85 VAC at full rated load.
ms
Input Current
MPU150
3.0
35
ARMS
Input Protection
Inrush Surge Current
Power Factor
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.
Per EN61000-3-2.
APK
0.95
W/VA
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
Switching frequency of Power Factor Correction circuit.
100
65
120
90
Operating Frequency
kHz
60
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - DC
Continuous input range.
36
75
VDC
Lowest DC input voltage that regulation is maintained with full
rated loads.
Brown Out Protection
34
20
VDC
Hold-up Time
Input Current
Input Protection
At 150 watts, over DC input range.
ms
36 VDC at full rated load.
6.4
ARMS
Non-user serviceable internally located AC input line fuse.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
100
70
Operating Frequency
Inrush Current
kHz
Consult factory.
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Full Rated Load, 110 VAC.
Varies with distribution of loads among outputs.
Efficiency
65
75
%
Minimum load required to maintain
Triple output models V1
4
3
0
regulation on, V2 at maximum load.
Quad output models V1
Minimum Load, V1
A
A
Minimum load required on single
Single output models V1
output models.
Minimum load required to maintain
regulation on V4 at maximum load.
Quad output models V3
Triple output models V3
0.3
0
Minimum Load, V3
Ripple and Noise
Output Power
Full load, 20 MHz bandwidth.
See Model Selection Charts
Watts
With 300 LFM forced air cooling.
(Note 1)
150
0
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on.
3
5
%
µs
Varies by output. Total regulation includes: line changes over
the specified. Input range, changes in load starting at 20% load
and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-
100% load change, 5% max. deviation.
Regulation
See Model Selection Charts
500
Transient Response
Turn-on Delay
Time required for initial output voltage stabilization.
2
s
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
50
ms
NOTE 1: This product is not rated for convection applications.
tech.support@psbel.com
5
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
2.5 V output, V1
3.3 V output, V1
3.3 V output, V2
5 V output, V1, V2
12 V output, V2
12 V output, V3
MPU150-4350G
3.3 V output, V1
3.0
4.1
3.8
6.0
14
14
4.3
3.25
4.65
4.2
6.4
16
19
4.65
Latch style overvoltage protection.
Available on V1, V2, all models,
and V3 on all models except
MPU150-3300G.
Overvoltage Protection
V
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature,
automatic reset.
Overload Protection
Overtemperature
Protection
TTL compatible signal available for V1. Pull-up resistor
is 10kΩ.
Signal is high when output is above the specified limits.
Signal shall remain low for 20 ms following loss of
Output Good.
3.3 V
5 V
3.16
4.75
3.25
4.90
Output Good Signal,
Low to High Transition
V
TTL compatible logic signal. Time before regulation dropout
Input Power Fail Warning due to loss of input power. May be used as independent
PSOK signal in redundant applications.
5
ms
Accuracy of shared current with up to 6 parallel units. Single
wire current share on V1 and V2 with return via -Sense return.
Current Share
10
%
Available on V1 and V2. Total voltage compensation for cable
losses with respect to the main output.
Remote Sense
500
mV
Output voltage is inhibited by application of an external high
(5V) signal.
Inhibit
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Approved to the latest edition of the following standards:
CSA/UL60950-1, EN60950-1 and IEC60950-1
Safety Approvals
Dielectric Withstand
Voltage
MPU150
MDU150
2600
1544
Input to output per EN60950.
VDC
Electromagnetic
Interference
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
B
B
Class
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
8
kV
V/M
kV
10
±2
MPU150: Line to Line
MPU150: Line to Ground
1
2
Input Transient Protection Per EN61000-4-5, class 3.
kV
MDU150: Line to Line
MDU150: Line to Ground
0.5
0.5
MΩ
Insulation Resistance
Leakage Current
Input to output.
Per EN60950.
10
22
1.7
Dual output MPU150 at 264 VAC
Single and triple output MPU150 at 264 VAC
MDU150 at 72 VDC
mA
(Not required by EN60950)
tech.support@psbel.com
6
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Operating.
Non-Operating.
10k
40k
50
Altitude
ASL Ft.
At 100% load
At 50% load
0
0
Operating Temperature
°C
Derate linearly above 50°C by 2.5% per °C.
70
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
-55
5
85
±0.05
95
°C
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
±0.02
%/°C
%RH
GPK
Peak acceleration.
20
Vibration
Random vibration, 10Hz to 2kHz, 3 axis.
6
GRMS
PARAMETER
Dimensions
Weight:
DESCRIPTION
8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm)
2 lb (0.89 kg)
MATES WITH MOLEX:
HOUSING SERIES 5264-N, P/N: 50-37-5103 (&)
PINS SERIES 5263, P/N: 80-70-1040 (LOOSE)
Figure 1. Mechanical Drawing – Single Output
tech.support@psbel.com
7
CONNECTOR
MOLEX SERIES
41695
HOUSING
09-50-8051
09-50-8051
09-50-3051
50-37-5103
PIN SERIES
6838
PINS (LOOSE)
08-50-0189
08-50-0106
08-50-0106
08-70-1040
PINS (CHAIN)
08-50-0187
08-50-0105
08-50-0105
08-70-1039
WIRE GAUGE
18-20AWG
18-20AWG
18-20AWG
22-28AWG
J1
41695
2478
(ALL MODELS)
2139
2478
J300
5264-N
5263
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH
Figure 2. Mechanical Drawing – Triple & Quad Output
tech.support@psbel.com
8
CONNECTOR
MOLEX SERIES
HOUSING
PIN SERIES
PINS (LOOSE)
PINS (CHAIN)
WIRE GAUGE
41695
41695
2139
09-50-8051
09-50-8051
09-50-3051
22-01-1022
22-01-1022
09-50-8021
09-50-8021
09-50-3021
09-50-8061
09-50-8061
09-50-3061
50-37-5103
6838
2478
2478
2759
2759
6838
2478
2478
6838
2478
2478
5263
08-50-0189
08-50-0106
08-50-0106
08-50-0114
08-65-0805
08-50-0189
08-50-0106
08-50-0106
08-50-0189
08-50-0106
08-50-0106
08-70-1040
08-50-0187
08-50-0105
08-50-0105
08-50-0113
08-65-0804
08-50-0187
08-50-0105
08-50-0105
08-50-0187
08-50-0105
08-50-0105
08-70-1039
18-20AWG
18-20AWG
18-20AWG
22-30AWG
22-30AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
22-28AWG
J1 (ALL MODELS)
5051-N
5051-N
41695
41695
2139
J2 (TRIPLE
OUTPUT)
J3 (TRIPLE
OUTPUT)
41695
41695
2139
J3 (QUAD
OUTPUT)
J300
5264-N
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
tech.support@psbel.com
相关型号:
MDU150-4530G
DC-DC Regulated Power Supply Module, 4 Output, 150W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL
©2020 ICPDF网 联系我们和版权申明