MDU200-1024DG [BEL]
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10;型号: | MDU200-1024DG |
厂家: | BEL FUSE INC. |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10 |
文件: | 总6页 (文件大小:214K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MPU200/MDU200 Series Data Sheet
Features
•
RoHS lead free solder and lead solder exempted products
are available
•
•
Power Factor Correction (PFC) meets EN61000-3-2
Same size, airflow, and construction as MPU150/MDU150
with over 33% more power
•
•
•
•
•
•
Single-wire current sense on quad model outputs V1 and V2
Remote sense on quad model outputs V1 and V2
Current share and N+1 redundancy (standard on all models)
Overtemperature, overload, and overvoltage protection
Available with SAE mountings
MDU200 models have 48 VDC input
Description
The MPU200/MDU200 Series is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products
incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. In this series,
200 watts of continuous output power is provided with single or multiple output units suited for distributed power or central power
applications. The series provides high current +3.3V and +5V on a single platform to support mixed-mode, high-speed digital
circuitry.
Power-One's dual-converter architecture combines high reliability with exceptional regulation. All multiple-output models feature
remote sense on outputs V1 and V2 to provide independent compensation of output cable losses.
Other standard features include independent current sharing on V1 and V2 quad-model outputs, thermal shutdown, and remote
inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of greater than 4.0 watts per cubic inch.
The MDU200 Series provides the same benefits as the MPU200 Series, with a nominal 48 VDC input.
AC Input, Single-Output Model Selection
200W/225W PK WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 2)
PEAK OUTPUT
CURRENT (NOTE 2) REGULATION
LINE
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 3)
INITIAL SETTING
ACCURACY
MODEL
MPU200-1012G
MPU200-1024G
MPU200-1048G
12V
24V
48V
11.6V to 16V
22.8V to 29.2V
45V to 56V
17.0A
8.35A
4.2A
19.0A
9.4A
4.7A
0.1%
0.1%
0.1%
1%
1%
1%
1%
1%
1%
11.97V to 12.03V
23.95V to 24.05V
47.9V to 48.1V
AC Input, Multiple-Output Model Selection
200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 2)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%Pk-Pk (NOTE 3)
INITIAL SETTING
ACCURACY
MODEL
+5V
+3.3V
12V
5.0V to 5.5V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
30A (Note 4)
15A (Note 4)
8A (Note 5)
4A (Note 5)
0.4%
0.6%
0.4%
0.4%
1%
1.5%
10%
10%
1%
1.5%
1%
4.98V to 5.02V
3.28V to 3.32V
11.94V to 12.06V
11.60V to 12.40V
MPU200-4530
12V
1%
NOTES: 1) This product is not rated for convection applications.
2) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended that the airflow be
applied from the input side of the power supply blowing towards the output.
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
4) Total current for V1 and V2 is not to exceed 35A.
5) Total power on V3 and V4 is not to exceed 100W.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Ordering Information:
OPTIONS
SUFFIXES TO ADD TO PART NUMBER
Metric Mounting
Add “M” as a suffix to the model number to order chassis with
M3 x 0.7 mounting inserts. Consult factory for availability.
Isolation Diode
Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed.
Consult factory for availability.
RoHS lead solder exemption
No RoHS suffix character required.
RoHS compliant for all 6 substances
Add “G” as the last character of the part number.
MCD10010 Rev. 1.1, 27-Jan-10
Page 1 of 6
www.power-one.com
MPU200/MDU200 Series Data Sheet
DC Input, Single Output Model Selection
200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 2) CURRENT (NOTE 2) REGULATION
PEAK OUTPUT
LINE
LOAD
REGULATION
RIPPLE & NOISE
%Pk-Pk (NOTE 3)
INITIAL SETTING
ACCURACY
MODEL
MDU200-1012G
12V
24V
11.6V to 16V
17.0A
8.35A
19.0A
9.4A
0.1%
0.1%
1%
1%
1%
1%
11.97V to 12.03V
23.95V to 24.05V
MDU200-1024G
(NOTE 4)
22.8V to 29.2V
MDU200-1048G
48V
45V to 56V
4.2A
4.7A
0.1%
1%
1%
47.9V to 48.1V
Isolation Diode Option - Offered on single-output models. Add “D” at the end of the part number if an isolation diode is needed.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
MPU200 Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
85
NOM
MAX
264
63
UNITS
Input Voltage - AC
Input Frequency
Hold-up Time
Continuous input range.
VAC
Hz
AC input.
47
After last AC line peak at 200 watts
85 VAC at full rated load.
15
ms
Input Current
4.0
35
ARMS
Input Protection
Inrush Surge Current
Power Factor
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.
Per EN61000-3-2.
APK
0.95
100
65
W/VA
Operating Frequency
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
Switching frequency of Power Factor Correction circuit.
120
90
kHz
60
MDU200 Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
36
NOM
MAX
UNITS
VDC
VDC
ms
Input Voltage - DC
Brown Out Protection
Hold-up Time
Continuous input range.
75
Lowest DC input voltage that regulation is maintained with full rated loads.
At 200 watts, over DC input range.
34
15
Input Current
36 VDC at full rated load.
8.35
ARMS
Input Protection
Inrush Surge Current
Operating Frequency
Non-user serviceable internally located AC input line fuse.
Consult factory.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
100
70
kHz
NOTES:1) This product is not rated for convection applications.
2) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended that the airflow be
applied from the input side of the power supply blowing towards the output.
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
4) Derating is required on output voltages above 27VDC. Consult factory.
MCD10010 Rev. 1.1, 27-Jan-10
Page 2 of 6
www.power-one.com
MPU200/MDU200 Series Data Sheet
Output Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Full Rated Load, 110 VAC (MPU) or 48VDC (MDU).
Varies with distribution of loads among outputs.
65
75
%
Minimum Load, V1
Minimum Load, V3
Minimum load required to maintain regulation on,
V2 at maximum load.
Minimum load required on single output models.
Quad output model V1
Single output models V1
3
0
A
A
Minimum load required to maintain regulation on
V4 at maximum load.
Quad output model V3
0.3
Ripple and Noise
Overshoot / Undershoot
Regulation
Full load, 20 MHz bandwidth.
See Model Selection Charts
5
Output voltage overshoot/undershoot at turn-on.
%
Varies by output. Total regulation includes: line changes over the specified.
input range, changes in load starting at 20% load and changing to 100% load.
See Model Selection Charts
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100% load change,
5% max. deviation.
500
2
μs
Turn-on Delay
Time required for initial output voltage stabilization.
s
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
MPU200
MDU200
50
80
ms
Interface Signals and Internal Protection
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Latch style overvoltage protection.
MPU200-4530 3.3V output
MPU200-4530 5V output
MPU200-4530 12V output
3.8
6.0
14
4.2
6.4
19
V
MDU200/MPU200-1012 V1 17.0
MDU200/MPU200-1024 V1 32.0
MDU200/MPU200-1048 V1 58.0
20.5
38.0
62.7
Overload Protection
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
Overtemperature Protection
Output Good Signal
(Transision from
Low to High)
TTL compatible signal available for V1. Internal pull-up resistor is 475⍀.
Signal is high when output is above the specified limits. Signal shall
remain low for 20 milliseconds following loss of Output Good.
3.3V 3.16
5V 4.75
3.25
4.95
V
MDU200/MPU200-1012 12V 10.5
MDU200/MPU200-1024 24V 21.5
MDU200/MPU200-1048 48V 43.0
11.9
23.5
47.0
Input Power Fail Warning
Current Share
Remote Sense
Inhibit
TTL compatible logic signal. Time before regulation dropout due to loss of input
power. May be used as independent PSOK signal in redundant applications.
5
ms
%
Accuracy of shared current with up to 6 parallel units. Single wire current share
on V1 and V2 with return via -Sense return.
10
Available on V1 and V2. Total voltage compensation for cable losses with
respect to the main output.
500
mV
Output voltage is inhibited by application of an external high (5V) signal.
MCD10010 Rev. 1.1, 27-Jan-10
Page 3 of 6
www.power-one.com
MPU200/MDU200 Series Data Sheet
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
UL60950,CSA 22.2 NO. 60950, and EN60950-1 (TÜV).
Input to output per EN60950.
(Approved)
Dielectric Withstand Voltage
MPU200 2600
MDU200 1414
VDC
Electromagnetic Interference
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
B
B
Class
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
8
kV
V/M
kV
10
±2
Input Transient Protection
Per EN61000-4-5, class 3.
MPU200:
Line to Line
1
MPU200:
MDU200:
MDU200:
Line to Ground
Line to Line
Line to Ground
2
0.5
0.5
kV
Insulation Resistance
Leakage Current
Input to output.
Per EN60950.
10
MV
mA
MPU200 Quad Output Model
MPU200 Single Output Models
2.2
1.7
N/A
MDU200 at 72 VDC
(Not required by EN60950)
Environmental Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating.
Non-Operating.
10k
40k
ASL Ft.
ASL Ft.
Operating Temperature
At 100% load
At 50% load
0
0
50
70
°C
°C
Derate linearly above 50°C by 2.5% per °C.
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
-55
85
±0.05
95
°C
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
±0.02
%/°C
%RH
GPK
5
Peak acceleration.
20
Vibration
Random vibration, 10Hz to 2kHz, 3 axis.
6
GRMS
Options
DESCRIPTION
NOTES
Metric Mounting
Add “M” as a suffix to the model number to order chassis with
M3 x 0.7 mounting inserts. Consult factory for availability.
Isolation Diode
Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed. Consult factory for
availability.
MCD10010 Rev. 1.1, 27-Jan-10
Page 4 of 6
www.power-one.com
MPU200/MDU200 Series Data Sheet
Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 2.0 lb (0.89 kg)
OUTPUTS:
SINGLE OUTPUT
8-32 SCREW
CONNECTIONS
(4PL)
+V1
RTN
INTERFACE CONNECTIONS (J300)
PIN
MDU200
DC
V1,V.
10. +S, V1
9. -S, V1
ADJ.
INPUT
J1
5
+
8. CURRENT SHARE, V1
7. NO CONNECTION
+
4
3
2
1
6. NO CONNECTION
5. NO CONNECTION
4. OUTPUT GOOD, V1
3. POWER FAIL WARNING
2. INHIBIT
MPU200
J1
1. SIGNAL GROUND
AC
L
1
3
5
INPUT
N
MOLEX SERIES 5268-NA, P/N: 22-05-7105, PINS
ON 2.50mm CENTERS.
MATES WITH MOLEX:
HOUSING SERIES 5264-N, P/N: 50-37-5103 (&)
PINS SERIES 5263, P/N: 80-70-1040 (LOOSE)
3
TBD
NOTE:
MAX. LEAD PROTRUSION IS 0.0625" (1.588mm)
ON THE FOUR BOTTOM MOUNTING HOLES.
MAX. LEAD PROTRUSION OF 0.25" (6.25mm)
IS ACCEPTABLE ON THE FOUR SIDE MOUNTING
HOLES.
MOLEX
SERIES
41695
41695
2139
PIN
PINS
PINS
WIRE
CONNECTOR
J1
HOUSING
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY,
WITH CLEAR FINISH
SERIES (LOOSE)
(CHAIN)
GAUGE
09-50-8051
09-50-8051
09-50-3051
6838 08-50-0189 08-50-0187 18-20AWG
2478 08-50-0106 08-50-0105 18-20AWG
2478 08-50-0106 08-50-0105 18-20AWG
J300
5264-N
50-37-5103
5263 08-70-1040 08-70-1039 22-28AWG
MCD10010 Rev. 1.1, 27-Jan-10
Page 5 of 6
www.power-one.com
MPU200/MDU200 Series Data Sheet
Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 2.0 lb (0.89 kg)
3
TBD
NOTE:
MAX. LEAD PROTRUSION IS 0.0625" (1.588mm)
ON THE FOUR BOTTOM MOUNTING HOLES.
MAX. LEAD PROTRUSION OF 0.25" (6.25mm)
IS ACCEPTABLE ON THE FOUR SIDE MOUNTING
HOLES.
MOLEX
SERIES
PIN
SERIES
PINS
(LOOSE)
PINS
(CHAIN)
WIRE
GAUGE
CONNECTOR
HOUSING
41695
41695
2139
5051-N
5051-N
41695
41695
2139
09-50-8051
09-50-8051
09-50-3051
22-01-1022
22-01-1022
09-50-8021
09-50-8021
09-50-3021
09-50-8061
09-50-8061
09-50-3061
50-37-5103
6838
2478
2478
2759
2759
6838
2478
2478
6838
2478
2478
5263
08-50-0189
08-50-0106
08-50-0106
08-50-0114
08-65-0805
08-50-0189
08-50-0106
08-50-0106
08-50-0189
08-50-0106
08-50-0106
08-70-1040
08-50-0187
08-50-0105
08-50-0105
08-50-0113
08-65-0804
08-50-0187
08-50-0105
08-50-0105
08-50-0187
08-50-0105
08-50-0105
08-70-1039
18-20AWG
18-20AWG
18-20AWG
22-30AWG
22-30AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
22-28AWG
J1
(ALL MODELS)
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY,
WITH CLEAR FINISH
J2
(TRIPLE OUTPUT)
J3
(TRIPLE OUTPUT)
41695
41695
2139
J3
(QUAD OUTPUT)
J300
5264-N
NUCLEAR AND MEDICALAPPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
MCD10010 Rev. 1.1, 27-Jan-10
Page 6 of 6
www.power-one.com
相关型号:
MDU200-1024G
Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints
POWER-ONE
MDU200-1048DG
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL
MDU200-1048G
Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints
POWER-ONE
MDU200-1048G
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL
©2020 ICPDF网 联系我们和版权申明