The MPB125 Series incorporates patented high
efficiency circuitry, high power density and active
Power Factor Correction (PFC) to meet the
requirements of networking and data
communications systems, as well as commercial and
industrial configurations.
Dual output units deliver a regulated main output plus
a second 12V output for fans or other system
functions. Multiple output models provide tightly
regulated DC power in a variety of configurations. The
MPB125 is rated for convection as well as forced-air
cooling.
Full output power is available with as few as 5 Cubic
Feet per Minute (CFM) forced-air cooling with the
exception of the MPB125-2003DG which need only
10 CFM for full power. Optional remote on/off with
standby power is also provided (see Options).
RoHS Lead Free and Lead-Solder-Exempt
Products are Available
High Power Density
Industry-Standard 3" x 5" Footprint
The MPB125 product line is approved to the latest
international regulatory standards, and displays the
CE Mark.
Power Factor Correction (PFC) Meets
EN61000-3-2
Main Output Remote Sense
Power Good signals
CE Marked to Low Voltage Directive
Input Transient & ESD Compliance to
EN61000-4-2/-3/-4/-5
MTBF In Excess of 1Million Hours based
upon field data
Optional Remote On/Off with 5V Standby
North America
+1-866.513.2839
Asia-Pacific
+86.755.29885888
Europe, Middle East
+353 61 225 977
tech.support@psbel.com
© 2015 Bel Power Solutions, Inc.
BCD.00597_AA
MPB125 Multiple-Output AC-DC Series
MAXIMUM OUTPUT
CURRENT (AMPS),
130 LFM
OUTPUT VOLTAGE
[V]
TOTAL REGULATION RIPPLE & NOISE 1
REGULATION
RANGE
MODEL
[%]
% pk-pk
+3.3V
+12V
+5V
30A
±3%
±5%
±3%
±5%
±3%
±5%
±3%
±5%
±3%
±5%
±3%
±5%
±4%
±5%
±5%
±3%
±4%
±5%
±5%
±3%
±4%
±5%
±5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1% 8
1%
1%
2%
1% 8
1%
1%
1.5%
1% 8
1%
1%
3.20V to 3.40V
11.80V to 12.60V
4.85V to 5.15V
MPB125-2003DG 2
MPB125-2005G 3, 4
MPB125-2012 3, 4, 5
MPB125-2015 3, 4, 5
MPB125-2024G 3, 4, 5
MPB125-2048 3, 4, 5
0.5A
25A
+12V
+12V
12V
0.5A
10.80V to 12.60V
11.64V to 12.36V
11.40V to 12.60V
14.54V to 15.45V
11.40V to 12.60V
23.28V to 24.72V
11.40V to 12.60V
46.56V to 49.44V
11.40V to 12.60V
4.85V to 5.25V
10.5A
0.5A
+15V
12V
8.3A
0.5A
+24V
12V
5.2A
0.5A
+48V
12V
2.6A
0.5A
+5V
16.5A
5A/9Apk
0.5A
12A 7
15A 7
5A/9Apk
0.5A
10A 7
15A 7
5A/9Apk
0.5A
MPB125-3000 6
MPB125-4250 6
+12V
-12V
+2.5V
+5V
11.40V to 12.60V
-11.40V to -12.60V
2.42V to 2.58V
4.85V to 5.25V
+12V
-12V
+3.3V
+5V
11.40V to 12.60V
-11.40V to -12.60V
3.20V to 3.40V
4.85V to 5.25V
MPB125-4350 6
+12V
-12V
11.40V to 12.60V
-11.40V to -12.60V
NOTES:
1
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
For MPB125-2003DG, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1.
V1 current can be as high as 25A with a minimum airflow of 5 CFM.
Maximum forced-air output power is 125 watts with 5 CFM airflow.
Maximum convection output power is 70 watts.
2
3
4
5
6
7
8
V2 is isolated from V1 and can be used as a negative or positive output.
V output’s peak load maximum duration is 30 seconds. Average current must not exceed 5A.
Maximum power of 80 watts from V1 + V2 with 5 CFM forced-air cooling. See Application Note #M3 for details.
For loads less than 10 watts on V1 + V2 + V3, ripple and noise on the +5V output is Max. 2% peak-to-peak.
OPTIONS
SUFFIXES TO ADD TO PART NUMBER
RoHS lead solder exempt 1
RoHS compliant for all 6 substances Add “G” as the last character of the part number.
Provided on dual-output models. Up to 4 units can be connected in parallel.
There are some limits for parallel operation. See MPB125 Applications Note.
No RoHS suffix character required.
Current Share (Option D)
N+1 redundancy is provided. V2 needs an external isolation diode for N+1 operation. An external
diode is required on MPB125-2003 and MPB125-2005 models for redundancy on both V1 and V2, or
when ordering, you can specify MPB125-2003D or -2005D which have an internal isolation diode
866.513.2839
tech.support@psbel.com
© 2015 Bel Power Solutions, Inc.
BCD.00597_AA
MPB125 Multiple-Output AC-DC Series
Remote On/Off is a TTL-compatible signal. A logic “high” or open circuit turns the unit on. Reverse
inhibit logic can be achieved by changing the position of the J6 connector. A logic “low” inhibits all
outputs except the 5V standby. At remote off, the Power Good signal will warn the host equipment 2
milliseconds before the main output goes out of regulation. The rating of the standby output is +5V @
0.2 Amps. Total regulation is ±5 %. Maximum noise and ripple is 50 mV peak-to-peak @ a 20 MHz
bandwidth.
Remote On/Off Standby Output
(Option R)
NOTE: The addition of Option “R” increases the supply width from 3.0 to 3.8 inches. Consult factory
for availability
1
The solder exemption refers to all the restricted materials except lead in solder.
PARAMETER
CONDITIONS/DESCRIPTION
MIN
90
NOM
MAX
264
63
UNITS
VAC
Hz
Input Voltage- AC
Input Frequency
Brownout Protection
Hold-up Time
Continuous input range
AC Input
47
Lowest AC input voltage that regulation is maintained with full rated loads
Over full AC input voltage range at full rated load
90 VAC at full rated load
90
VAC
ms
17
Input Current
1.8
ARMS
Non-user serviceable internally located AC input line fuse, 250 VAC,
3.15A.
Input Protection
110 VAC:
Internally limited by thermistor, one cycle, 25° C
220 VAC:
23
46
Inrush Surge Current
APK
Power Factor Circuitry
Operating Frequency
Active PFC meets requirements of EN61000-3-2
Switching frequency of main transformer.
45
kHz
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Full Load, 230VAC. Varies with distribution of loads among outputs.
(Minimum efficiency reflects that of MPB125-2003D and -2005D models.)
Efficiency
73
80
85
%
V1 + V2 + V3 for MPB125-4XXX and -3000.
V1 for MPB125-2XXX for full regulation on V2.
All models operate at no load without any damage and meet all specs on
V1 above 0 amps.
5
5
Minimum Loads
Watts
Ripple and Noise
Full load, 20 MHz bandwidth
See Model Selection Chart
125
At 5 CFM forced-air cooling. See Application Note #M3 for details.
Convection: Consult Factory
Output Power (Note 1)
Overshoot /Undershoot
Watts
Output voltage overshoot/undershoot at turn-on
10
%
Varies by output. Total regulation includes: line changes from 85-132 VAC
or 170-264 VAC, changes in load starting at 20% load and changing to
100% load
Regulation
See Model Selection Chart
Maximum deviation due to a 25% load change with unit at 75% load.
All models except MPB125-2005G and -2005D
Model MPB125-2005G and -2005D
3
5
Transient Response
Turn-on Delay
%
Time required for initial output voltage stabilization
0.2
0.2
1.5
20
Sec
ms
Time required for output voltage to rise from 10% to 90% except for
MPB125-2005G and -2005D
Turn-on Rise Time
MPB125-2005G and MPB125-2005D
1
100
866.513.2839
tech.support@psbel.com
© 2015 Bel Power Solutions, Inc.
BCD.00597_AA
MPB125 Multiple-Output AC-DC Series
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
V1 of dual and triple output models; V1 & V2 outputs of 4-output models.
MPB125-2003 and -2003D
3.67
3.20
3.76
5.74
13.5
17.0
26.9
57.6
4.80
4.00
4.80
7.00
16.5
19.0
31.1
62.4
MPB125-4250 (V1)
MPB125-4350 (V1)
5V Output of MPB125-2005 and -2005D, MPB125-3000, or MPB125-4X50
Overvoltage Protection
VDC
MPB125-2012
MPB125-2015
MPB125-2024
MPB125-2048
Fully protected against output short circuit or overload. Automatic
recovery upon removal of overload condition.
MPB125-2003, -2003D -2005, and -2005D latch OFF if overload occurs on
Overload Protection
V1 which requires an AC reset.
Remote Sense (Note 2)
Dual Output Models
Total (+sense and -sense) voltage compensation for cable losses on dual
output models.
500
mV
On models MPB125-4350 remote sense is provided on the 2.5 and 3.3V
outputs, respectively.
MPB125-3000 does not have positive remote sense.
Total voltage compensation for cable losses on +Sense.
Total voltage compensation for cable losses on -Sense.
Remote Sense (Note 2)
Triple & Quad Output
Models
200
100
mV
ms
AC/DC indicator - This signal indicates the status of the AC input or DC
outputs. When there is sufficient AC voltage and the outputs are
operating normally, an open collector signal is provided.
Turn-On delay time from application of AC:
Warning time before outputs go out of regulation:
Warning time before outputs deviate ±10% from the nominal value:
Sync Current
50
5
15
500
Power Good Signal
20
30
mA
V
Pull-up Voltage
Provided on dual-output models. Open collector signal intended to drive an
LED.
Closed collector occurs when the Power Good Signal is in its open collector
state.
Power Supply OK Signal
20
30
mA
V
Sync Current
Pull-up Voltage
Protected against overtemperature conditions.
Unit recovers when overtemperature condition is removed.
Internal isolation diode is provided on V1 for all dual-output models except
the MPB125-2003 and MPB125-2005. Specify MPB125-2003D or
MPB125-2005D, respectively, if an internal isolation diode is required for
these models.
Thermal Shutdown
Isolation Diode
NOTES:
1) For MPB125-2003, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1. V1 current can be as
high as 25A with a minimum airflow of 5 CFM.
2) -Sense must be connected to output common or load common for proper power supply operation.
866.513.2839
tech.support@psbel.com
© 2015 Bel Power Solutions, Inc.
BCD.00597_AA
MPB125 Multiple-Output AC-DC Series
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Approved to latest edition of the following standards: UL/CSA60950-1,
IEC60950-1 and EN60950-1.
Agency Approvals
Input to Chassis
Input to Output (Tested by manufacturer only)
2121
4242
VDC
VDC
Dielectric Withstand Voltage
Electromagnetic Interference EN55022 Conducted
B
8
Class
kV
ESD Susceptibility
Flicker
Per EN61000-4-2, Level 4
Per EN61000-3-3
Radiated Susceptibility
EFT/Burst
Per EN61000-4-3
3
V/m
kV
Per EN61000-4-4
1
Per EN61000-4-5, Level 3,
2 kV (Line-to-Ground) minimum,
1 kV (Line-to-Line) minimum.
Input Transient Protection
RF Immunity
Per EN61000-4-6. 0.15 to 80 MHz (1 kHz sine wave)
Per EN61000-4-8
3
1
V/m
A/m
Magnetic Fields
Voltage Dips
Per EN61000-4-11
Insulation Resistance
Leakage Current
Input to output.
10
MΩ
Per EN60950 (264 VAC)
1.0
mA
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Operating
Non-Operating
10K
50K
Altitude
ASL Feet
Derate linearly from 50 to 70°C to 50% power at 70°C.
MPB125 models will operate at -20°C, but will not meet all specifications.
At 100% load:
Operating Temperature
Storage Temperature
0
50
85
°C
°C
-40
Forced-air cooling of 5 CFM is required for full output power
except for MPB125-2003 and -2003D. Air velocity is measured
with power supply mounted on 0.375" (9.5mm) standoffs.
Airflow direction is from the input section to the output section.
See Application Note #M3 for details.
Forced-Air Cooling 1)
Temperature Coefficient
Relative Humidity
Included in total regulation of outputs
Non-Condensing
5
95
%RH
Gpk
Operating: 11 ±3ms, 3 axes, Half Sine
Non-operating: 11 ±3ms, 3 axes, Half Sine
15
40
Shock
Operating: Random vibration, 5-500 Hz, 10 minutes each axis.
Non-Operating: Random vibration, 5-500 Hz, 10 minutes each axis
2.4
6.0
Vibration
GRMS
NOTES:
1
For MPB125-2003 and -2003D, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1.
V1 current can be as high as 25A with a minimum airflow of 5 CFM.
866.513.2839
tech.support@psbel.com
© 2015 Bel Power Solutions, Inc.
BCD.00597_AA
MPB125 Multiple-Output AC-DC Series
Figure 1 - Mechanical Drawing (-2012, -2015, -2024, & -2048 Models)
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
MPB125-2012, -2015, -2024, -2048
09-50-8031
Housing
J1
Pins
08-52-0113
Housing
09-50-8061
J2
Pins
08-52-0113
Housing
22-01-3067
J3
Pins
08-50-0114
Housing
22-01-3027
J4
Pins
08-50-0114
866.513.2839
tech.support@psbel.com
© 2015 Bel Power Solutions, Inc.
BCD.00597_AA
MPB125 Multiple-Output AC-DC Series
Figure 2 - Mechanical Drawing (-2003, -2003D, -2005, and -2005D Models)
PRINTED CIRCUIT BOARD
0.19"
(4.8)
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
MPB125-2005
09-50-8031
08-52-0113
09-50-8103
08-52-0113
22-01-3057
08-50-0114
22-01-3027
08-50-0114
Housing
J1
Pins
Housing
J2
Pins
Housing
J3
Pins
Housing
J4
Pins
866.513.2839
tech.support@psbel.com
© 2015 Bel Power Solutions, Inc.
BCD.00597_AA
MPB125 Multiple-Output AC-DC Series
Figure 3 - Mechanical Drawing (-3000, -4250, & -4350 Models)
J1 - AC INPUT CONNECTOR
PRINTED CIRCUIT BOARD
0.19"
(4.8)
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
MPB125-3000, -4250, -4350
09-50-8033
Housing
J1
Pins
08-52-0113
Housing
09-50-8143
J2
Pins
08-52-0113
Housing
22-01-3037
J3
Pins
08-50-0114
866.513.2839
tech.support@psbel.com
© 2015 Bel Power Solutions, Inc.
BCD.00597_AA
MPB125 Multiple-Output AC-DC Series
MPB125 Series “R” Option
Figure 4 - Mechanical Drawing (-2012R, -2015R, -2024R, & -2048R Models)
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
MPB125-2012, -2015, -2024, -2048
Housing
Pins
09-50-8033
08-52-0113
09-50-8063
08-52-0113
22-01-3067
08-50-0114
22-01-3027
08-50-0114
22-01-3037
08-50-0114
J1
J2
J3
J4
J5
Housing
Pins
Housing
Pins
Housing
Pins
Housing
Pins
866.513.2839
tech.support@psbel.com
© 2015 Bel Power Solutions, Inc.
BCD.00597_AA
MPB125 Multiple-Output AC-DC Series
MPB125 Series “R” Option
Mechanical Drawing (-3000R, -4250R, & -4350R Models)
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
MPB125-3000R, -4250R, -4350R
09-50-8033
Housing
J1
08-52-0113
Pins
09-50-8143
Housing
J2
08-52-0113
Pins
22-01-3037
08-50-0114
22-01-3037
08-50-0114
Housing
Pins
J3
J5
Housing
Pins
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support
systems, equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending
on the date manufactured. Specifications are subject to change without notice.
866.513.2839
tech.support@psbel.com
© 2015 Bel Power Solutions, Inc.
BCD.00597_AA
相关型号:
©2020 ICPDF网 联系我们和版权申明