CTD-2X2005AXTX [CARLOGAVAZZI]

Accessories AC Current Transformer;
CTD-2X2005AXTX
型号: CTD-2X2005AXTX
厂家: Carlo Gavazzi    Carlo Gavazzi
描述:

Accessories AC Current Transformer

文件: 总2页 (文件大小:310K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Accessories  
AC Current Transformer (max 30x10 mm bus-bar)  
Type CTD-2X  
Bus-bar type current transformer  
0.5 class, currents from 40 to 600 A  
Integrated DIN-rail mounting holder  
Removable panel fixing clips  
•2 Bus-bar isolated fixing screws  
Double screw terminals (up to 8-wire connections)  
Sealable terminal block covers  
Product Description  
Ordering Key  
CTD-2X 200 5A XXX  
Cable/Bus-bar type current ty. Rated primary currents Model  
transformer with DIN-rail/bus- from 40 A to 600 A.  
bar and panel mounting facili-  
Primary current  
Secondary current  
Option  
Optional fixing kit:  
CTD-kit  
Type Selection  
Primary current  
Secondary current  
Option  
From 40 to 600A  
1A  
5A  
XXX: none  
(Refer to Range Table)  
XTX: tropicalization  
Input Specifications  
Operating frequency  
Max. system voltage  
Rated insulation level  
Insulation class  
45 to 65 Hz  
0.72 kV  
3 kV/1 min. @ 50 Hz  
E (max 75°C)  
Six plastic caps for  
cable/bus-bar fixing screws.  
Special features  
1 A secondary current,  
Tropicalization  
Working temperature  
-25°C to +60°C (-13°F to  
140°F) (R.H. < 90% non  
condensing @ 40°C)  
-30°C to +70°C (-22°F to  
158°F) (R.H. < 90% non  
condensing @ 40°C)  
Short-time current rating  
Ith  
Typical 100 In /1 s  
Idyn  
2.5 Ith  
Storage temperature  
Approvals  
The short-time thermal  
current Ith is anyway limited  
by the cable/ bus-bar size  
CE, cUrus and CSA  
Extended current rating  
Security factor (FS)  
120%  
Connection  
Screw type  
≤ 5 (Class: 0.5, 1 and 3)  
Cable cross section area  
From 1.5 to 6 mm2  
Min/Max screws tightening  
torque relevant to terminal  
block screws:  
General Specifications  
Standards  
Housing  
From 1 to 2 Nm  
According to EN61869-2  
ABS, self-extinguishing:  
UL 94 V-0  
DIN-rail bus-bar  
and panel mounting  
Max screws tightening  
torque relevant to the  
cable/bus-bar fixing screws:  
0,3 Nm  
Mounting  
Protection degree  
Cable diameter  
IP00  
Standard accessories  
Two terminal block screws.  
Two cable/bus-bar  
fixing screws.  
IP20 (with sealable terminal  
block covers + wire terminals)  
Max. 24 mm  
Two sealable terminal block  
Bus-bar size  
covers.  
Horizontal  
Max. 32x5; 30x10; 25x20  
mm  
Max. 25x12 mm  
Two panel mounting  
fixing clips.  
Two plastic caps for  
cable/bus-bar fixing screws.  
Extended fixing kit: CTD-kit  
Two panel mounting  
fixing clips.  
Six cable/bus-bar fixing  
screws.  
Vertical  
Weight  
From 350 to 500 g  
Optional accessories  
Output Specifications  
Rated secondary current  
5 A or 1 A  
Specifications are subject to change without notice CTD-2X DS ENG 14016  
1
CTD-2X  
Range Table  
Model CTD-2X from 40A to 125A  
Model CTD-2X from 150A to 600A  
Primary Current  
Burden (VA)  
CL 1  
Primary Current  
Burden (VA)  
A
CL 0.5  
CL 3  
1.25  
1.5  
2
A
CL 0.5  
CL 1  
4
CL 3  
5
40 (@60°C/140°F)  
50 (@60°C/140°F)  
60 (@60°C/140°F)  
70 (@60°C/140°F)  
75 (@60°C/140°F)  
80 (@60°C/140°F)  
100 (@60°C/140°F)  
120 (@60°C/140°F)  
125 (@60°C/140°F)  
150 (@60°C/140°F)  
160 (@60°C/140°F)  
200 (@60°C/140°F)  
250 (@60°C/140°F)  
300 (@60°C/140°F)  
400 (@50°C/122°F)  
500 (@50°C/122°F)  
600 (@40°C/104°F)  
3
3
4
5
4
5
6.5  
8
2.5  
2.5  
2.75  
3
5.5  
7
7
1.75  
2
8.5  
13.5  
15.5  
19  
9.5  
14.5  
16.5  
20  
12  
14  
17.5  
2.5  
2.75  
2.75  
3.75  
3.75  
2
Benefits  
1
2
3
4
5
6
7
8
9
10  
• Easy and quick mounting either on a panel  
or on a DIN-rail (see figure 1-2).  
Dimensions (mm)  
• Protection of screw terminals using specific  
sealable covers to assure always the best  
safety (see figure 3).  
63  
30  
• Bridging of current transformer output  
without changing the connection of the  
secondary, so to avoid any output  
overvoltage during either the maintenance or  
the installation procedure (see figure 4).  
• Easy output and earth connection (see fig. 5).  
• Screw terminals compatible with any kind of  
wire terminals (see figure 6-7-8-9).  
φ 24  
• Multiple screws provided with isolation cap  
screws to grant a strong and reliable fixing of  
the current transformer to the bus-bar (see  
figure 10).  
28  
Wiring Diagram  
S1  
S2  
12,5  
25,5  
42  
30,5  
32,5  
L
56  
P1  
P2  
N
2
Specifications are subject to change without notice CTD-2X DS ENG 140116  

相关型号:

CTD-2X2005AXXX

Accessories AC Current Transformer
CARLOGAVAZZI

CTD-3X8001AXTX

Accessories AC Current Transformer
CARLOGAVAZZI

CTD-3X8001AXXX

Accessories AC Current Transformer
CARLOGAVAZZI

CTD-3X8005AXTX

Accessories AC Current Transformer
CARLOGAVAZZI

CTD-3X8005AXXX

Accessories AC Current Transformer
CARLOGAVAZZI

CTD-4X12501AXTX

Accessories AC Current Transformer
CARLOGAVAZZI

CTD-4X12501AXXX

Accessories AC Current Transformer
CARLOGAVAZZI

CTD-4X12505AXTX

Accessories AC Current Transformer
CARLOGAVAZZI

CTD-4X12505AXXX

Accessories AC Current Transformer
CARLOGAVAZZI

CTD-55S4001AXTX

Accessories AC Split-Core Current Transformer
CARLOGAVAZZI

CTD-55S4001AXXX

Accessories AC Split-Core Current Transformer
CARLOGAVAZZI

CTD-55S4005AXTX

Accessories AC Split-Core Current Transformer
CARLOGAVAZZI