date 09/28/2020  
page 1 of 6  
SERIES: VGS-100C DESCRIPTION: INTERNAL AC-DC POWER SUPPLY  
FEATURES  
• universal input range (85 ~ 264 VAC)  
• UL/EN/IEC 62368 certified  
• designed to meet IEC/EN 61558, IEC/EN 60335, and GB4943 system requirements  
• short-circuit, over-current, over-voltage protections  
• CISPR/EN55032 Class B radiated/conducted emissions  
• output adjustable via trimpot +/- 10%  
output  
voltage  
output  
current  
max  
output  
power  
max  
ripple  
efficiency2  
MODEL  
and noise1  
typ  
typ  
(Vdc)  
5
(A)  
(W)  
(mVp-p)  
(%)  
VGS-100C-5  
VGS-100C-12  
VGS-100C-15  
VGS-100C-24  
VGS-100C-36  
VGS-100C-48  
18  
90.0  
100  
120  
120  
150  
200  
200  
86  
88  
88  
90  
90  
91  
12  
15  
24  
36  
48  
8.5  
7.0  
4.5  
2.8  
2.3  
102.0  
105.0  
108.0  
100.8  
110.4  
Notes:  
1. Ripple & noise are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output.  
2. Measured at 230 Vac  
PART NUMBER KEY  
VGS-100C - XX - X  
A - with terminal cover  
B - with conformal coating  
Base Number  
Output Voltage  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100C DESCRIPTION: AC-DC POWER SUPPLY  
date 09/28/2020 page 2 of 6  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
ac input  
dc input  
85  
120  
264  
373  
Vac  
Vdc  
voltage  
frequency  
current  
47  
63  
Hz  
at 115 Vac  
at 230 Vac  
3
1.5  
A
A
at 115 Vac, cold start  
at 230 Vac, cold start  
35  
65  
A
A
inrush current  
leakage current  
at 240 Vac  
0.75  
mA  
no load power consumption  
5V, 12V, 15V, 24V at 230 Vac  
36V, 48V at 230 Vac  
0.3  
0.5  
W
W
OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
5 Vdc output  
12 Vdc output  
15 Vdc output  
24 Vdc output  
36 Vdc output  
48 Vdc output  
10,000  
6,800  
3,300  
2,200  
1,000  
470  
μF  
μF  
μF  
μF  
μF  
μF  
capacitive load  
5 Vdc output at full load  
other outputs at full load  
±2  
±1  
%
%
initial set point accuracy  
line regulation  
load regulation  
adjustability  
±0.5  
%
5 Vdc output 0%~100% load  
other outputs 0%~100% load  
±1  
±0.5  
%
%
built in trim pot  
±10  
%
at 115 Vac  
at 230 Vac  
5
45  
ms  
ms  
hold-up time  
switching frequency  
65  
kHz  
temperature coefficient  
±0.03  
%/°C  
PROTECTIONS  
parameter  
conditions/description  
min  
typ  
max  
units  
5 Vdc output, output shut-down, auto-recovery  
7.5  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
12 Vdc output, output shut-down, auto-recovery  
15 Vdc output, output shut-down, auto-recovery  
24 Vdc output, output shut-down, auto-recovery  
36 Vdc output, output shut-down, auto-recovery  
48 Vdc output, output shut-down, auto-recovery  
19.2  
24.0  
38.4  
57.6  
60.0  
over voltage protection  
over current protection  
short circuit protection  
auto-recovery  
110  
160  
%
hiccup, continuous, auto-recovery  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
input to ground  
input to output  
output to ground  
2,000  
4,000  
1,250  
Vac  
Vac  
Vac  
isolation voltage  
safety approvals  
certified to:  
62368: IEC/EN/UL  
designed to meet: 60335: IEC/EN  
designed to meet: 61558: IEC/EN  
designed to meet: 4943: GB  
safety class  
EMI/EMC  
ESD  
Class I  
CISPR32/EN55032 Class B, IEC/EN61000-3-2 Class A  
IEC/EN 61000-4-2 Contact ±6KV /Air ±8KV, perf. Criteria A  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100C DESCRIPTION: AC-DC POWER SUPPLY  
date 09/28/2020 page 3 of 6  
SAFETY & COMPLIANCE  
radiated immunity  
IEC/EN 61000-4-3 10V/m, perf. Criteria A  
IEC/EN 61000-4-4 ±2KV, perf. Criteria A  
EFT/burst  
surge  
IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV, perf. Criteria A  
IEC/EN61000-4-6 10 Vr.m.s, perf. Criteria A  
conducted immunity  
voltage dips and interruptions  
IEC/EN61000-4-11 0%, 70%, perf. Criteria B  
MTBF  
RoHS  
as per MIL-HDBK-217F at 25°C  
yes  
300,000  
hours  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-30  
-40  
20  
typ  
max  
70  
units  
°C  
operating temperature  
storage temperature  
operating humidity  
storage humidity  
85  
°C  
non-condensing  
non-condensing  
90  
%
10  
95  
%
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100C DESCRIPTION: AC-DC POWER SUPPLY  
date 09/28/2020 page 4 of 6  
MECHANICAL  
parameter  
conditions/description  
min  
typ  
max  
units  
dimensions  
129.00 x 97.00 x 30.00  
mm  
5 Vdc output  
other outputs  
350  
305  
g
g
weight  
cooling  
natural convection  
case material  
metal (AL1100, SGCC)  
MECHANICAL DRAWING  
units: mm [inch]  
tolerance: ±1.0 [±0.039]  
wire range: 22-12 AWG  
connector tightening torque: M3.5, 0.8 N·m  
PIN CONNECTIONS  
PIN  
1
Function  
AC(L)  
2
AC(N)  
3
4
-Vo  
-Vo  
5
6
+Vo  
+Vo  
7
Position  
Screw  
spec.  
L (max)  
Torque  
(max)  
2 - 4  
7 - 8  
M3  
M3  
5 mm  
3 mm  
0.4 N·m  
0.4 N·m  
Note: At least one hole position, 1 ~ 9, must be securely connected  
to Protective Earth (PE)  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100C DESCRIPTION: AC-DC POWER SUPPLY  
date 09/28/2020 page 5 of 6  
DERATING CURVE  
EFFICIENCY CURVES  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100C DESCRIPTION: AC-DC POWER SUPPLY  
date 09/28/2020 page 6 of 6  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
09/28/2020  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a  
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.  

相关型号:

VGS-100C-36

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100C-48

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100C-5

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100D

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100D-12

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100D-15

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100D-24

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100D-48

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100D-5

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100W

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100W-12

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100W-15

INTERNAL AC-DC POWER SUPPLY
CUI