VGS-100D-15 [CUI]

INTERNAL AC-DC POWER SUPPLY;
VGS-100D-15
型号: VGS-100D-15
厂家: CUI INC    CUI INC
描述:

INTERNAL AC-DC POWER SUPPLY

文件: 总6页 (文件大小:1182K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Additional Resources: Product Page  
|
3D Model  
date 12/14/2020  
page 1 of 6  
SERIES: VGS-100D DESCRIPTION: INTERNAL AC-DC POWER SUPPLY  
FEATURES  
• wide input range (85 ~ 305 VAC)  
• available with conformal coating or terminal cover options  
• active Power Factor Correction (PFC)  
• certified to IEC/EN/UL 62368  
• designed to meet IEC/EN 61558, IEC/EN 60335, and GB4943  
• output over voltage, over current, over temperature, short circuit protection  
• CISPR/EN55032 Class B radiated/conducted emissions  
• input over voltage category III for fixed installations  
output  
voltage  
output  
current  
max  
(A)  
output  
power  
max  
ripple  
efficiency3  
MODEL  
and noise2  
max  
(mVp-p)  
typ  
(%)  
range1  
(Vdc)  
5
(W)  
(Vdc)  
VGS-100D-5  
VGS-100D-12  
VGS-100D-15  
VGS-100D-24  
VGS-100D-48  
4.75 ~ 5.5  
11.4 ~ 13.8  
14.3 ~ 16.5  
22.8 ~ 27.6  
45.6 ~ 55.2  
20.0  
8.5  
6.7  
4.2  
2.1  
100.0  
102.0  
100.5  
100.8  
100.8  
100  
100  
100  
150  
250  
86  
85  
86  
86  
87  
12  
15  
24  
48  
Notes:  
1. Output adjustable via built-in trimpot. The actual adjustment range may extend beyond the values listed and care should be taken to ensure the output voltage  
and output power do not exceed stated limits.  
2. Ripple & noise are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output.  
3. Measured at 230 Vac  
PART NUMBER KEY  
VGS-100D - XX - X  
Base Number  
A - with terminal cover  
B - with conformal coating  
Output Voltage  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100D DESCRIPTION: AC-DC POWER SUPPLY  
date 12/14/2020 page 2 of 6  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
85  
120  
264  
373  
Vac  
Vdc  
5 Vdc output model  
voltage  
85  
120  
305  
430  
Vac  
Vdc  
all other output models  
frequency  
current  
47  
63  
Hz  
at 85 Vac  
at 115 Vac  
at 230 Vac  
1.7  
1.3  
0.7  
A
A
A
at 115 Vac, cold start  
at 230 Vac, cold start  
25  
45  
A
A
inrush current  
leakage current  
power factor  
at 240 Vac  
2
mA  
at 115 Vac, full load  
at 230 Vac, full load  
0.97  
0.92  
OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
5 Vdc output  
12 Vdc output  
15 Vdc output  
24 Vdc output  
48 Vdc output  
5,000  
5,000  
5,000  
4,200  
2,200  
μF  
μF  
μF  
μF  
μF  
capacitive load  
at full load  
5, 12 & 15 Vdc output  
24 & 48 Vdc output  
initial set point accuracy  
line regulation  
±2  
±1  
%
%
±0.5  
%
0%~100% load  
5 Vdc output model  
all other output models  
load regulation  
±1.0  
±0.5  
%
%
hold-up time  
at 230 Vac  
16  
ms  
temperature coefficient  
±0.05  
%/°C  
turn on (0 ~ 0.8 Vdc)  
turn off (4 ~ 10 Vdc)  
remote on/off (CTRL)  
PROTECTIONS  
parameter  
conditions/description  
min  
typ  
max  
units  
5 Vdc output model, hiccup  
12 Vdc output model, hiccup  
15 Vdc output model, hiccup  
24 Vdc output model, hiccup  
48 Vdc output model, hiccup  
7.5  
16.8  
20.25  
32.4  
60.0  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
over voltage protection  
over current protection  
over temperature protectionꢀ  
short circuit protection  
constant current, auto-recovery  
105  
150  
85  
%
over temperature protection activation  
over temperature protection deactivation  
°C  
°C  
50  
constant current, continuous, auto-recovery  
Note: 1. Over temperature protection thresholds under full load conditions.  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100D DESCRIPTION: AC-DC POWER SUPPLY  
date 12/14/2020 page 3 of 6  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
input to ground, 1 min, <10mA  
input to output, 1 min, <10mA  
output to ground, 1 min, <5mA  
2,000  
4,000  
500  
Vac  
Vac  
Vac  
isolation voltage  
safety approvals  
certified to  
62368: IEC, EN, UL  
designed to meet 60335: EN  
designed to meet 61558: EN  
designed to meet GB4943  
safety class  
Class I  
conducted emissions  
radiated emissions  
harmonic current  
voltage flicker  
ESD  
CISPR32/EN55032 CLASS B  
CISPR32/EN55032 CLASS B  
IEC/EN61000-3-2  
IEC/EN 61000-3-3  
IEC/EN 61000-4-2 Contact ±6KV/Air ±8KV perf. Criteria A  
IEC/EN61000-4-3 3V/m perf. Criteria B  
radiated immunity  
EFT/burst  
IEC/EN61000-4-4 ±2KV perf. Criteria A  
IEC/EN61000-4-5 line to line ±1kV/line to ground ±2kV perf. Criteria A  
IEC/EN61000-4-6 10Vr.m.s perf. Criteria A  
surge  
conducted immunity  
voltage dips and interruptions  
MTBF  
IEC/EN61000-4-11 0%, 70% perf. Criteria B  
as per MIL-HDBK-217F at 25°C  
yes  
300,000  
hours  
RoHS  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-30  
-40  
20  
typ  
max  
70  
units  
°C  
operating temperature  
storage temperature  
operating humidity  
storage humidity  
see derating curve  
85  
°C  
non-condensing  
non-condensing  
90  
%
10  
95  
%
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100D DESCRIPTION: AC-DC POWER SUPPLY  
date 12/14/2020 page 4 of 6  
MECHANICAL  
parameter  
conditions/description  
min  
typ  
max  
units  
dimensions  
179 × 99 × 30  
mm  
5 Vdc output model  
all other models  
530  
460  
g
g
weight  
cooling  
natural convection  
case material  
metal (AL1100, SGCC)  
MECHANICAL DRAWING  
units: mm [inch]  
tolerance: ±1.0 [±0.039]  
wire range: 22-12 AWG  
connector tightening torque: M3.5, 0.8 N·m  
PIN CONNECTIONS  
PIN  
1
Function  
+Vo  
2
+Vo  
3
-Vo  
4
-Vo  
5
6
AC(N)  
AC(L)  
7
Note: At least one hole position,  
1 ~ 6 , must be securely connected  
to Protective Earth (PE).  
CN1: KANGDAO TJC3-NAWD-2P  
PIN  
1
FUNCTION  
RC+  
CONNECTOR  
TERMINAL  
KANGDAO  
XI-25001-2Y  
KANGDAO  
XH2.54-TE  
2
RC-  
SCREW  
SPEC  
TORQUE  
(MAX)  
POSITION  
1 ~ 6  
L (MAX)  
4mm  
M4  
0.9N·m  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100D DESCRIPTION: AC-DC POWER SUPPLY  
date 12/14/2020 page 5 of 6  
DERATING CURVE  
EFFICIENCY CURVES  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100D DESCRIPTION: AC-DC POWER SUPPLY  
date 12/14/2020 page 6 of 6  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
12/14/2020  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a  
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.  

相关型号:

VGS-100D-24

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100D-48

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100D-5

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100W

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100W-12

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100W-15

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100W-24

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100W-36

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100W-48

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-100W-5

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-150B

AC-DC POWER SUPPLY
CUI

VGS-150B-12

AC-DC POWER SUPPLY
CUI