VGS-100D-15 [CUI]
INTERNAL AC-DC POWER SUPPLY;型号: | VGS-100D-15 |
厂家: | CUI INC |
描述: | INTERNAL AC-DC POWER SUPPLY |
文件: | 总6页 (文件大小:1182K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Additional Resources: Product Page
|
3D Model
date 12/14/2020
page 1 of 6
SERIES: VGS-100D │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY
FEATURES
• wide input range (85 ~ 305 VAC)
• available with conformal coating or terminal cover options
• active Power Factor Correction (PFC)
• certified to IEC/EN/UL 62368
• designed to meet IEC/EN 61558, IEC/EN 60335, and GB4943
• output over voltage, over current, over temperature, short circuit protection
• CISPR/EN55032 Class B radiated/conducted emissions
• input over voltage category III for fixed installations
output
voltage
output
current
max
(A)
output
power
max
ripple
efficiency3
MODEL
and noise2
max
(mVp-p)
typ
(%)
range1
(Vdc)
5
(W)
(Vdc)
VGS-100D-5
VGS-100D-12
VGS-100D-15
VGS-100D-24
VGS-100D-48
4.75 ~ 5.5
11.4 ~ 13.8
14.3 ~ 16.5
22.8 ~ 27.6
45.6 ~ 55.2
20.0
8.5
6.7
4.2
2.1
100.0
102.0
100.5
100.8
100.8
100
100
100
150
250
86
85
86
86
87
12
15
24
48
Notes:
1. Output adjustable via built-in trimpot. The actual adjustment range may extend beyond the values listed and care should be taken to ensure the output voltage
and output power do not exceed stated limits.
2. Ripple & noise are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output.
3. Measured at 230 Vac
PART NUMBER KEY
VGS-100D - XX - X
Base Number
A - with terminal cover
B - with conformal coating
Output Voltage
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-100D │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/14/2020 │ page 2 of 6
INPUT
parameter
conditions/description
min
typ
max
units
85
120
264
373
Vac
Vdc
5 Vdc output model
voltage
85
120
305
430
Vac
Vdc
all other output models
frequency
current
47
63
Hz
at 85 Vac
at 115 Vac
at 230 Vac
1.7
1.3
0.7
A
A
A
at 115 Vac, cold start
at 230 Vac, cold start
25
45
A
A
inrush current
leakage current
power factor
at 240 Vac
2
mA
at 115 Vac, full load
at 230 Vac, full load
0.97
0.92
OUTPUT
parameter
conditions/description
min
typ
max
units
5 Vdc output
12 Vdc output
15 Vdc output
24 Vdc output
48 Vdc output
5,000
5,000
5,000
4,200
2,200
μF
μF
μF
μF
μF
capacitive load
at full load
5, 12 & 15 Vdc output
24 & 48 Vdc output
initial set point accuracy
line regulation
±2
±1
%
%
±0.5
%
0%~100% load
5 Vdc output model
all other output models
load regulation
±1.0
±0.5
%
%
hold-up time
at 230 Vac
16
ms
temperature coefficient
±0.05
%/°C
turn on (0 ~ 0.8 Vdc)
turn off (4 ~ 10 Vdc)
remote on/off (CTRL)
PROTECTIONS
parameter
conditions/description
min
typ
max
units
5 Vdc output model, hiccup
12 Vdc output model, hiccup
15 Vdc output model, hiccup
24 Vdc output model, hiccup
48 Vdc output model, hiccup
7.5
16.8
20.25
32.4
60.0
Vdc
Vdc
Vdc
Vdc
Vdc
over voltage protection
over current protection
over temperature protectionꢀ
short circuit protection
constant current, auto-recovery
105
150
85
%
over temperature protection activation
over temperature protection deactivation
°C
°C
50
constant current, continuous, auto-recovery
Note: 1. Over temperature protection thresholds under full load conditions.
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-100D │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/14/2020 │ page 3 of 6
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
input to ground, 1 min, <10mA
input to output, 1 min, <10mA
output to ground, 1 min, <5mA
2,000
4,000
500
Vac
Vac
Vac
isolation voltage
safety approvals
certified to
62368: IEC, EN, UL
designed to meet 60335: EN
designed to meet 61558: EN
designed to meet GB4943
safety class
Class I
conducted emissions
radiated emissions
harmonic current
voltage flicker
ESD
CISPR32/EN55032 CLASS B
CISPR32/EN55032 CLASS B
IEC/EN61000-3-2
IEC/EN 61000-3-3
IEC/EN 61000-4-2 Contact ±6KV/Air ±8KV perf. Criteria A
IEC/EN61000-4-3 3V/m perf. Criteria B
radiated immunity
EFT/burst
IEC/EN61000-4-4 ±2KV perf. Criteria A
IEC/EN61000-4-5 line to line ±1kV/line to ground ±2kV perf. Criteria A
IEC/EN61000-4-6 10Vr.m.s perf. Criteria A
surge
conducted immunity
voltage dips and interruptions
MTBF
IEC/EN61000-4-11 0%, 70% perf. Criteria B
as per MIL-HDBK-217F at 25°C
yes
300,000
hours
RoHS
ENVIRONMENTAL
parameter
conditions/description
min
-30
-40
20
typ
max
70
units
°C
operating temperature
storage temperature
operating humidity
storage humidity
see derating curve
85
°C
non-condensing
non-condensing
90
%
10
95
%
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-100D │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/14/2020 │ page 4 of 6
MECHANICAL
parameter
conditions/description
min
typ
max
units
dimensions
179 × 99 × 30
mm
5 Vdc output model
all other models
530
460
g
g
weight
cooling
natural convection
case material
metal (AL1100, SGCC)
MECHANICAL DRAWING
units: mm [inch]
tolerance: ±1.0 [±0.039]
wire range: 22-12 AWG
connector tightening torque: M3.5, 0.8 N·m
PIN CONNECTIONS
PIN
1
Function
+Vo
2
+Vo
3
-Vo
4
-Vo
5
6
AC(N)
AC(L)
7
Note: At least one hole position,
1 ~ 6 , must be securely connected
to Protective Earth (PE).
CN1: KANGDAO TJC3-NAWD-2P
PIN
1
FUNCTION
RC+
CONNECTOR
TERMINAL
KANGDAO
XI-25001-2Y
KANGDAO
XH2.54-TE
2
RC-
SCREW
SPEC
TORQUE
(MAX)
POSITION
1 ~ 6
L (MAX)
4mm
M4
0.9N·m
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-100D │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/14/2020 │ page 5 of 6
DERATING CURVE
EFFICIENCY CURVES
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-100D │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/14/2020 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
12/14/2020
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明