MDU14-8MC4 [DATADELAY]
QUAD, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU14); QUAD , ECL -接口固定的延时线(系列MDU14 )型号: | MDU14-8MC4 |
厂家: | DATA DELAY DEVICES, INC. |
描述: | QUAD, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU14) |
文件: | 总4页 (文件大小:34K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MDU14
Ò
QUAD, ECL-INTERFACED
FIXED DELAY LINE
(SERIES MDU14)
data
3
delay
inc.
devices,
PACKAGES
FEATURES
1
2
3
4
5
6
7
8
24
I1
N/C
I2
N/C
I3
GND
VEE
N/C
I4
GND
N/C
O1
N/C
O2
GND
GND
N/C
O3
N/C
O4
GND
O1
I1
1
3
24
·
·
·
·
Four independent delay lines
Fits 24-pin (400mil) DIP socket
Auto-insertable
23
22
21
20
19
18
17
16
15
14
13
I2
22
O2
GND
GND
20
19
18
I3
5
6
7
Input & outputs fully 100K-ECL interfaced & buffered
GND
VEE
9
10
11
12
N/C
N/C
GND
I4
O3
O4
16
13
9
N/C
MDU14-xx
MDU14-xxM Military DIP
DIP
11
DDU14-xxC4
DDU14-xxMC4 Mil SMD
SMD
GND
FUNCTIONAL DESCRIPTION
PIN DESCRIPTIONS
The MDU14-series device is a 4-in-1 digitally buffered delay line. The
I1-I4
O1-O4 Signal Outputs
VEE -5 Volts
GND Ground
Signal Inputs
signal inputs (I1-I4) are reproduced at the outputs (O1-O4), shifted in time
by an amount determined by the device dash number (See Table). The
delay lines function completely independently of each other.
SERIES SPECIFICATIONS
DASH NUMBER SPECIFICATIONS
·
·
·
·
·
·
Minimum input pulse width: 40% of total delay
Output rise time: 2ns typical
Supply voltage: -5VDC ± 5%
Power dissipation: 500mw typical (no load)
Operating temperature: 0° to 85° C
Temp. coefficient of total delay: 100 PPM/°C
Part
Number
MDU14-2
Total
Delay (ns)
2.0 ± 1.0
2.5 ± 1.0
3.0 ± 1.0
4.0 ± 1.0
5.0 ± 1.0
6.0 ± 1.0
7.0 ± 1.0
8.0 ± 1.0
9.0 ± 1.0
10.0 ± 1.0
12.5 ± 1.0
15.0 ± 1.0
20.0 ± 1.0
25.0 ± 1.2
MDU14-2.5
MDU14-3
MDU14-4
MDU14-5
MDU14-6
MDU14-7
MDU14-8
MDU14-9
MDU14-10
MDU14-12.5
MDU14-15
MDU14-20
MDU14-25
O1
100%
I1
O2
100%
I2
O3
100%
I3
O4
100%
I4
NOTE: Any dash number between 2 and 25
not shown is also available.
VCC
GND
Functional block diagram
Ó1997 Data Delay Devices
Doc #97042
12/15/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
1
MDU14
APPLICATION NOTES
Delay Devices if your application requires device
testing at a specific input condition.
HIGH FREQUENCY RESPONSE
The MDU14 tolerances are guaranteed for input
pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 40% of the total delay and periods as
small as 80% of the total delay (for a symmetric
input), the delays may deviate from their values at
low frequency. However, for a given input
POWER SUPPLY BYPASSING
The MDU14 relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VEE to GND,
located as close as possible to the VEE pin, is
recommended. A wide VEE trace and a clean
ground plane should be used.
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER
DC Supply Voltage
Input Pin Voltage
Storage Temperature
Lead Temperature
SYMBOL
VEE
VIN
TSTRG
TLEAD
MIN
-7.0
VEE - 0.3
-55
MAX
0.3
0.3
150
300
UNITS NOTES
V
V
C
C
10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 85C)
PARAMETER
SYMBOL
MIN
TYP
MAX
-0.880
-1.620
-0.880
-1.475
340
UNITS
NOTES
VIH = MAX,50W to -2V
VIL = MIN, 50W to -2V
High Level Output Voltage
Low Level Output Voltage
High Level Input Voltage
Low Level Input Voltage
High Level Input Current
Low Level Input Current
VOH
VOL
VIH
VIL
IIH
-1.025
-1.810
-1.165
-1.810
V
V
V
V
mA
mA
VIH = MAX
VIL = MIN
IIL
0.5
Doc #97042
12/15/97
DATA DELAY DEVICES, INC.
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
2
MDU14
PACKAGE DIMENSIONS
24
22
3
20 19 18
16
9
13
.530
MAX.
1
5
6
7
11
1.300 MAX.
.015 .300
TYP. MAX.
.130
.030
±
.012 TYP.
.018 TYP.
.100 TYP.
.400
TYP.
1.100 TYP.
MDU14-xx (Commercial DIP)
MDU14-xxM (Military DIP)
.020 TYP.
.040 TYP.
.010 .002
±
24 23 22 21 20 19 18 17 16 15 14 13
.882
.005
.710 .590
MAX.
±
.005
±
.007
.005
±
1
2
3
4
5
6
7
8
9
10 11 12
.100
.090
.280
MAX.
.050
.010
1.100
1.280 .020
±
±
MDU14-xxC4 (Commercial SMD)
MDU14-xxMC4 (Military SMD)
Doc #97042
12/15/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
3
MDU14
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT:
OUTPUT:
Ambient Temperature: 25oC ± 3oC
Supply Voltage (Vcc): -5.0V ± 0.1V
Load:
Cload
50W to -2V
5pf ± 10%
:
Input Pulse:
Standard 10KH ECL
Threshold: (VOH + VOL) / 2
levels
(Rising & Falling)
Source Impedance:
Rise/Fall Time:
50W Max.
2.0 ns Max. (measured
between 20% and 80%)
PWIN = 1.5 x Total Delay
PERIN = 10 x Total Delay
Pulse Width:
Period:
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
REF
PULSE
GENERATOR
OUT
I1
I2
I3
I4
O1
O2
O3
O4
IN
OSCILLOSCOPE
TRIG
TRIG
DEVICE UNDER
TEST (DUT)
Test Setup
PERIN
PWIN
VIH
TRISE
TFALL
INPUT
SIGNAL
80%
50%
20%
80%
50%
20%
VIL
TRISE
TFALL
OUTPUT
SIGNAL
VOH
50%
50%
VOL
Timing Diagram For Testing
Doc #97042
12/15/97
DATA DELAY DEVICES, INC.
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com