MDU150-3300G [BEL]
AC-DC Power Factor Correction Module,;型号: | MDU150-3300G |
厂家: | BEL FUSE INC. |
描述: | AC-DC Power Factor Correction Module, |
文件: | 总6页 (文件大小:253K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MPU150/MDU150 Series Data Sheet
Features
•
RoHS lead free solder and lead solder exempted products
are available
•
•
•
Power Factor Correction (PFC) meets EN61000-3-2
Low-profile height fits 1U constraints
Dual main outputs provide 3.3V and 5V for mixed mode
applications
•
•
•
•
•
•
Single wire current sense on outputs V1 and V2
Remote sense on outputs V1 and V2
Overtemperature, overload, and overvoltage protection
Available with metric or SAE mountings
Greater than 340,000 Hours MTBF
MDU150 models have 48VDC input
Description
The innovative MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U
height constraints. The MPU150-4530 and MPU150-4350 provide high current +3.3V and +5V on a single platform to support
mixed-mode, high-speed digital circuitry. Power-One’s unique dual converter architecture combines high reliability with
exceptional regulation.
All multiple output models feature remote sense on outputs V1 and V2 to provide independent compensation of output cable
losses. Other standard features include independent current sharing on V1 and V2, thermal shutdown, and remote inhibit.
Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of 3.0 watts per cubic inch.
The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.
AC Input, Single Output Model Selection - 180W WITH 300 LFM FORCED-AIR COOLING
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
MODEL
MPU150-S259
MPU150-S262
MPU150-S261
12V
24V
48V
11.6V to 16V
22.8V to 29.2V
45V to 56V
15A (Note 3)
7.5A (Note 3)
3.75A (Note 3)
0.1%
0.1%
0.1%
1%
1%
1%
1%
1%
1%
11.97V to 12.03V
23.95V to 24.05V
47.9V to 48.1V
Model numbers highlighted in yellow or shaded are not recommended for new designs. See MPU200 for new designs.
AC Input, Multiple Output Model Selection - 150W WITH 300 LFM FORCED-AIR COOLING
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%Pk-Pk (NOTE 2)
INITIAL SETTING
ACCURACY
MODEL
+3.3V
+5V
+12V
+5V
+12V
+24V
+5V
+12V
12V
3.15V to 3.80V
5.0V to 5.5V
Fixed
5.0V to 5.5V
10.8V to 13.2V
Fixed
35A
20A
2A
17.5A
4A
0.6%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.8%
0.6%
0.4%
0.4%
0.6%
0.4%
0.4%
0.4%
0.4%
0.6%
0.4%
0.4%
1.5%
3%
3%
1%
3%
3%
1%
1%
1%
1%
2%
1.5%
1%
1%
1.5%
1%
7%
7%
1%
1.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
2%
1.5%
1%
1%
1%
1%
1%
1%
1%
1.5%
1%
1%
3.28V to 3.32V
4.98V to 5.02V
11.76V to 12.24V
4.98V to 5.02V
11.94V to 12.06V
23.52V to 24.48V
4.98V to 5.02V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
2.49V to 2.51V
3.28V to 3.32V
11.94V to 12.06V
4.98V to 5.0V
3.28V to 3.32V
5.00V to 5.04V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
3.28V to 3.32V
11.94V to 12.06V
11.94V to 12.06V
MPU150-3300
MPU150-3524
MPU150-4000
2A
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
2.25V to 3.0V
3.15V to 3.8V
10.8V to 13.2V
5.0V to 5.5V
3.15V to 3.80V
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
30A (Note 4)
8A
3A
2A
5V
+2.5V
+3.3V
12V
5V
+3.3V
+5V
12V
12V
+5V
+3.3V
12V
30A (Note 4)
15A (Note 4)
4A (Note 5)
2A (Note 5)
30A (Note 4)
15A (Note 4)
3A (Note 5)
3A (Note 5)
30A (Note 4)
15A (Note 4)
3A (Note 5)
3A (Note 5)
MPU150-4230
MPU150-4350
MPU150-4530
1.5%
7%
7%
12V
NOTES: 1) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under
ALL load conditions. It is recommended that the airflow be applied from the input side of the
power supply blowing towards the output.
4) Total current between V1 and V2 is 30A, maximum rating.
5) Total current between V3 and V4 is 5A, maximum rating.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Total power of 180 Watts.
MCD10009 Rev. 1.0, 15-Oct-07
Page 1 of 6
www.power-one.com
MPU150/MDU150 Series Data Sheet
DC Input Model Selection -
150W WITH 300 LFM FORCED-AIR COOLING
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
OUTPUT
MODEL
ADJUSTMENT
RANGE
OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%Pk-Pk (NOTE 2)
INITIAL SETTING
ACCURACY
VOLTAGE
+3.3V
3.15V to 3.80V
5.0V to 5.5V
N/A
35A
20A
2A
0.6%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
2%
1.5%
1%
1%
1.5%
1%
7%
1.5%
3%
3%
1%
1%
1%
1%
2%
1.5%
1%
1%
1.5%
1%
7%
7%
1.5%
1%
1%
1%
1%
1%
1%
2%
1.5%
1%
1%
1%
1%
1%
1%
1%
3.28V to 3.32V
4.98V to 5.02V
11.76V to 12.24V
4.98V to 5.02V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
2.49V to 2.51V
3.28V to 3.32V
11.94V to 12.06V
4.98V to 5.0V
3.28V to 3.32V
5.00V to 5.04V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
MDU150-3300
MDU150-4000
+5V
+12V
+5V
+12V
12V
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
2.25V to 3.0V
3.15V to 3.8V
10.8V to 13.2V
5.0V to 5.5 V
3.15V to 3.8V
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
30A (Note 3)
8A
3A
2A
5V
+2.5V
+3.3V
12V
5V
+3.3V
+5V
12V
12V
+5V
30A (Note 3)
15A (Note 3)
3A
MDU150-4230
MDU150-4350
2A
30A (Note 5)
15A (Note 5)
3A (Note 4)
3A (Note 4)
30A (Note 3)
7%
0.4%
1%
+3.3V
12V
12V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
15A (Note 3)
3A (Note 4)
3A (Note 4)
0.6%
0.4%
0.4%
1.5%
7%
7%
1.5%
1%
1%
3.28V to 3.32V
11.94V to 12.06V
11.94V to 12.06V
MDU150-4530
NOTES: 1) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling
under ALL load conditions. It is recommended that the airflow be applied from the
input side of the power supply blowing towards the output.
4) Total current between V3 and V4 is 5A, maximum rating.
5) Total current between V1 and V2 is 40A, maximum rating
2) Maximum peak-to-peak noise expressed as a percentage of output voltage,
20 MHz bandwidth.
3) Total current between V1 and V2 is 30A, maximum rating.
Ordering Information:
OPTIONS
SUFFIXES TO ADD TO PART NUMBER
Metric Mounting
Add “M” as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. Metric mounting
inserts are standard for single-output models MPU150-S259, MPU150-S261, and MPU150-S262.
RoHS lead solder exemption
No RoHS suffix character required.
RoHS compliant for all 6 substances
Add “G” as the last character of the part number.
MPU150 Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
85
47
17.5
20
NOM
MAX
264
63
UNITS
VAC
Hz
Input Voltage - AC
Input Frequency
Hold-up Time
Continuous input range.
AC input.
After last AC line peak at 150 watts.
MPU150-4350
All other models
MPU150
ms
Input Current
85 VAC at full rated load.
3.0
35
ARMS
Input Protection
Inrush Surge Current
Power Factor
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.
Per EN61000-3-2.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
Switching frequency of Power Factor Correction circuit.
APK
W/VA
0.95
100
65
Operating Frequency
120
90
kHz
60
MCD10009 Rev. 1.0, 15-Oct-07
Page 2 of 6
www.power-one.com
MPU150/MDU150 Series Data Sheet
MDU150 Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
36
34
20
NOM
MAX
UNITS
VDC
VDC
ms
Input Voltage - DC
Brown Out Protection
Hold-up Time
Continuous input range.
Lowest DC input voltage that regulation is maintained with full rated loads.
At 150 watts, over DC input range.
75
Input Current
36 VDC at full rated load.
6.4
ARMS
Input Protection
Operating Frequency
Non-user serviceable internally located AC input line fuse.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
Consult factory.
100
70
kHz
Inrush Current
Output Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Full Rated Load, 110 VAC. Varies with distribution of loads among outputs.
65
75
%
Minimum Load, V1
Minimum load required to maintain regulation on,
V2 at maximum load.
Minimum load required on single output models.
Triple output models V1
Quad output models V1
Single output models V1
4
3
0
A
A
Minimum Load, V3
Minimum load required to maintain regulation on
V4 at maximum load.
Quad output models V3
Triple output models V3
0.3
0
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Full load, 20 MHz bandwidth.
With 300 LFM forced air cooling. (Note 1)
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes over the specified.
input range, changes in load starting at 20% load and changing to 100% load.
See Model Selection Charts
150
Watts
%
0
3
5
See Model Selection Charts
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100% load change,
5% max. deviation.
500
µs
Turn-on Delay
Time required for initial output voltage stabilization.
2
s
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
50
ms
NOTES: 1) This product is not rated for convection applications.
Interface Signals and Internal Protection
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Latch style overvoltage protection. Available on
V1, V2, all models, and V3 on all models except
MPU150-3300.
2.5V output, V1 3.0
3.3V output, V1 4.1
3.3V output, V2 3.8
5V output, V1, V2 6.0
3.25
4.65
4.2
6.4
12V output, V2
12V output, V3
MPU150-4350G 3.3V output, V1 4.3
MPU150-S259 V1 17.0
14
14
16
19
4.65
20.5
38.0
62.7
V
MPU150-S262 V1 32.0
MPU150-S261 V1 58.0
Overload Protection
Overtemperature Protection
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
Output Good Signal,
Low to High Transition
TTL compatible signal available for V1. Pull-up resistor is 10k⍀. Signal
is high when output is above the specified limits. Signal shall remain low
3.3V 3.16
5V 4.75
3.25
4.90
11.9
23.5
47.0
for 20 milliseconds following loss of Output Good.
MPU150-S259 12V 10.5
MPU150-S262 24V 21.5
MPU150-S261 48V 43.0
V
Input Power Fail Warning
Current Share
Remote Sense
Inhibit
TTL compatible logic signal. Time before regulation dropout due to loss of input
power. May be used as independent PSOK signal in redundant applications.
Accuracy of shared current with up to 6 parallel units. Single wire current share
on V1 and V2 with return via -Sense return.
Available on V1 and V2. Total voltage compensation for cable losses with
respect to the main output.
Output voltage is inhibited by application of an external high (5V) signal.
5
ms
%
10
500
mV
MCD10009 Rev. 1.0, 15-Oct-07
Page 3 of 6
www.power-one.com
MPU150/MDU150 Series Data Sheet
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (TÜV).
Approved
Dielectric Withstand Voltage
Electromagnetic Interference
Input to output per EN60950.
MPU150 2600
MDU150 1544
VDC
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
B
B
Class
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
Per EN61000-4-5, class 3.
8
10
2
1
2
kV
V/M
kV
Input Transient Protection
MPU150:
MPU150:
MDU150:
MDU150:
Line to Line
Line to Ground
kV
Line to Line 0.5
Line to Ground 0.5
Insulation Resistance
Leakage Current
Input to output.
Per EN60950.
10
M⍀
Dual output MPU150 at 264 VAC
Single and triple output MPU150 at 264 VAC
MDU150 at 72 VDC
22
1.7
mA
(Not required by EN60950)
Environmental Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating.
Non-Operating.
10k
40k
ASL Ft.
ASL Ft.
Operating Temperature
At 100% load
At 50% load
0
0
50
70
°C
°C
Derate linearly above 50°C by 2.5% per °C.
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
-55
85
0.05
95
20
6
°C
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
Peak acceleration.
0.02
%/°C
%RH
GPK
5
Vibration
Random vibration, 10Hz to 2kHz, 3 axis.
GRMS
Options
DESCRIPTION
NOTES
SIZE IMPACT
Metric Mounting
Add “M” as a suffix to the model number to order chassis with
M4 x 0.7 mounting inserts. Metric mounting inserts are standard for
single-output models MPU150-S259, MPU150-S261, and MPU150-S262.
8.00" x 4.20" x 1.50"
(203.2mm x 106.7mm x 38.1mm)
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date
manufactured. Specifications are subject to change without notice.
MCD10009 Rev. 1.0, 15-Oct-07
Page 4 of 6
www.power-one.com
MPU150/MDU150 Series Data Sheet
Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 1.8 lb (0.82 kg)
OUTPUTS:
SINGLE OUTPUT
8-32 SCREW
CONNECTIONS
(4PL)
+V1
RTN
INTERFACE CONNECTIONS (J300)
PIN
V1,V.
10. +S, V1
9. -S, V1
ADJ.
J1
INPUT
L
8. CURRENT SHARE, V1
7. NO CONNECTION
N
6. NO CONNECTION
5. NO CONNECTION
4. OUTPUT GOOD, V1
3. POWER FAIL WARNING
2. INHIBIT
1. SIGNAL GROUND
MOLEX SERIES 5268-NA, P/N: 22-05-7105, PINS
ON 2.50mm CENTERS.
MATES WITH MOLEX:
HOUSING SERIES 5264-N, P/N: 50-37-5103 (&)
PINS SERIES 5263, P/N: 80-70-1040 (LOOSE)
M4 X 0.7, 8 PLACES.
MAXIMUM TORQUE: 3.5 IN/LBS (0.40 N/M)
NOTE:
MAX. LEAD PROTRUSION IS 0.0625" (1.588mm)
ON THE FOUR BOTTOM MOUNTING HOLES.
MAX. LEAD PROTRUSION OF 0.25" (6.25mm)
IS ACCEPTABLE ON THE FOUR SIDE MOUNTING
HOLES.
MOLEX
SERIES
41695
41695
2139
PIN
PINS
PINS
WIRE
CONNECTOR
J1
HOUSING
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY,
GAUGE
SERIES
(LOOSE)
(CHAIN)
09-50-8051
09-50-8051
09-50-3051
6838
2478
2478
08-50-0189
08-50-0106
08-50-0106
08-50-0187
08-50-0105
08-50-0105
18-20AWG
18-20AWG
18-20AWG
WITH CLEAR FINISH
(ALL MODELS)
J300
5264-N
50-37-5103
5263
08-70-1040
08-70-1039
22-28AWG
MCD10009 Rev. 1.0, 15-Oct-07
Page 5 of 6
www.power-one.com
MPU150/MDU150 Series Data Sheet
Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 2.0 lb (0.89 kg)
NOTE:
MAX. LEAD PROTRUSION IS 0.0625" (1.588mm)
ON THE FOUR BOTTOM MOUNTING HOLES.
MAX. LEAD PROTRUSION OF 0.25" (6.25mm)
IS ACCEPTABLE ON THE FOUR SIDE MOUNTING
HOLES.
MOLEX
SERIES
PIN
SERIES
PINS
(LOOSE)
PINS
(CHAIN)
WIRE
GAUGE
CONNECTOR
HOUSING
41695
41695
2139
5051-N
5051-N
41695
41695
2139
09-50-8051
09-50-8051
09-50-3051
22-01-1022
22-01-1022
09-50-8021
09-50-8021
09-50-3021
09-50-8061
09-50-8061
09-50-3061
50-37-5103
6838
2478
2478
2759
2759
6838
2478
2478
6838
2478
2478
5263
08-50-0189
08-50-0106
08-50-0106
08-50-0114
08-65-0805
08-50-0189
08-50-0106
08-50-0106
08-50-0189
08-50-0106
08-50-0106
08-70-1040
08-50-0187
08-50-0105
08-50-0105
08-50-0113
08-65-0804
08-50-0187
08-50-0105
08-50-0105
08-50-0187
08-50-0105
08-50-0105
08-70-1039
18-20AWG
18-20AWG
18-20AWG
22-30AWG
22-30AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
22-28AWG
J1
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY,
WITH CLEAR FINISH
(ALL MODELS)
J2
(TRIPLE OUTPUT)
J3
(TRIPLE OUTPUT)
41695
41695
2139
J3
(QUAD OUTPUT)
J300
5264-N
MCD10009 Rev. 1.0, 15-Oct-07
Page 6 of 6
www.power-one.com