MDU150-4000 [POWER-ONE]

Power Factor Correction (PFC) Meets EN61000-3-2; 功率因数校正( PFC ),符合EN61000-3-2
MDU150-4000
型号: MDU150-4000
厂家: POWER-ONE    POWER-ONE
描述:

Power Factor Correction (PFC) Meets EN61000-3-2
功率因数校正( PFC ),符合EN61000-3-2

功率因数校正
文件: 总4页 (文件大小:159K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
MPU/MDU150 SERIES  
The innovative MPU150 incorporates Power Factor Correction (PFC)  
with a low profile package designed to meet 1U height constraints.  
The MPU150-4530 and MPU150-4350 provide high current +3.3V  
and +5V on a single platform to support mixed mode, high speed  
digital circuitry. Power-One’s unique dual converter architecture  
combines high reliability with exceptional regulation.  
All models feature remote sense on outputs V1 and V2 to provide  
independent compensation of output cable losses. Other standard  
features include independent current sharing on V1 and V2, thermal  
shutdown, and remote inhibit. Airflow of 300 linear feet per minute  
(LFM) is required to deliver the full power density of 3.0 watts per  
cubic inch.  
The MDU150 series provides the same benefits as the MPU150 series,  
with nominal 48 volt DC input.  
FEATURES  
Power Factor Correction (PFC) Meets EN61000-3-2  
Low Profile Height Fits 1U Constraints  
Dual Main Outputs Provide 3.3V and 5V for Mixed Mode Applications  
Single Wire Current Sense on Outputs V1 and V2  
Remote Sense on Outputs V1 and V2  
Overtemperature, Overload, and Overvoltage Protection  
Available with Metric or SAE Mountings  
Greater than 340,000 Hours MTBF  
MDU150 Models have 48VDC Input  
AC INPUT MODEL SELECTION CHART – 150W WITH 300 LFM FORCED AIR COOLING  
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
OUTPUT  
CURRENT (NOTE 1)  
LINE  
REGULATION  
LOAD  
REGULATION  
RIPPLE & NOISE  
%Pk-Pk (NOTE 2)  
INITIAL SETTING  
ACCURACY  
MODEL  
+3.3V  
+5V  
+12V  
+5V  
+12V  
12V  
5V  
+3.3V  
+5V  
12V  
12V  
+5V  
3.15V to 3.80V  
5.0V to 5.5V  
10.8V to 13.2V  
5.0V to 5.5V  
10.8V to 13.2V  
10.8V to 13.2V  
5.0V to 5.5V  
3.15V to 3.80V  
5.0V to 5.5V  
10.8V to 13.2V  
10.8V to 13.2V  
5.0V to 5.5V  
3.15V to 3.60V  
10.8V to 13.2V  
10.8V to 13.2V  
35A  
20A  
2A  
0.6%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.6%  
0.4%  
0.4%  
0.4%  
0.4%  
0.6%  
0.4%  
0.4%  
1.5%  
3%  
3%  
1%  
1%  
1%  
1%  
1.5%  
1%  
7%  
7%  
1%  
1.5%  
7%  
7%  
1.5%  
1%  
1%  
1%  
1%  
1%  
1%  
1.5%  
1%  
1%  
1%  
1%  
1.5%  
1%  
1%  
3.28V to 3.32V  
4.98V to 5.02V  
11.76V to 12.24V  
4.98V to 5.02V  
11.94V to 12.06V  
11.94V to 12.06V  
4.98V to 5.02V  
3.28V to 3.32V  
5.00V to 5.04V  
11.94V to 12.06V  
11.94V to 12.06V  
4.98V to 5.02V  
3.28V to 3.32V  
11.94V to 12.06V  
11.94V to 12.06V  
MPU150-3300  
30A (Note 3)  
8A  
MPU150-4000  
MPU150-4350  
MPU150-4530  
3A  
2A  
30A (Note 3)  
15A (Note 3)  
3A (Note 4)  
3A (Note 4)  
30A (Note 3)  
15A (Note 3)  
3A (Note 4)  
3A (Note 4)  
+3.3V  
12V  
12V  
DC INPUT MODEL SELECTION CHART – 150W WITH 300 LFM FORCED AIR COOLING  
Advanced Product Release  
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
OUTPUT  
CURRENT (NOTE 1)  
LINE  
REGULATION  
LOAD  
REGULATION  
RIPPLE & NOISE  
%Pk-Pk (NOTE 2)  
INITIAL SETTING  
ACCURACY  
MODEL  
+3.3V  
+5V  
+12V  
+5V  
+12V  
12V  
5V  
+5V  
+3.3V  
12V  
3.15V to 3.80V  
5.0V to 5.5V  
10.8V to 13.2V  
5.0V to 5.5V  
10.8V to 13.2V  
10.8V to 13.2V  
5.0V to 5.5V  
35A  
20A  
2A  
0.6%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.6%  
0.4%  
0.4%  
1.5%  
3%  
3%  
1%  
1%  
1%  
1%  
1%  
1.5%  
7%  
1.5%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1.5%  
1%  
3.28V to 3.32V  
4.98V to 5.02V  
11.76V to 12.24V  
4.98V to 5.02V  
11.94V to 12.06V  
11.94V to 12.06V  
4.98V to 5.02V  
4.98V to 5.02V  
3.28V to 3.32V  
11.94V to 12.06V  
11.94V to 12.06V  
MDU150-3300  
30A (Note 3)  
8A  
MDU150-4000  
MDU150-4530  
3A  
2A  
5.0V to 5.5V  
30A (Note 3)  
15A (Note 3)  
3A (Note 4)  
3A (Note 4)  
3.15V to 3.60V  
10.8V to 13.2V  
10.8V to 13.2V  
12V  
7%  
1%  
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air.  
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.  
3) Total current between V1 and V2 is 30A, maximum rating.  
4) Total current between V3 and V4 is 5A, maximum rating.  
Rev. 06/99  
1
®
MPU/MDU150 SERIES  
MPU150 INPUT SPECIFICATIONS  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
85  
47  
17.5  
20  
NOM  
MAX  
264  
63  
UNITS  
VAC  
Hz  
Input Voltage - AC  
Input Frequency  
Hold-up Time  
Continuous input range.  
AC input.  
After last AC line peak at 150 watts.  
MPU150-4350  
All other models  
mS  
Input Current  
85 VAC at full rated load.  
3.0  
35  
ARMS  
Input Protection  
Inrush Surge Current  
Power Factor  
Non-user serviceable internally located AC input line fuse.  
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.  
Per EN61000-3-2.  
Switching frequency of main output transformer.  
Switching frequency of secondary transformer.  
Switching frequency of Power Factor Correction circuit.  
APK  
W/VA  
0.95  
100  
65  
Operating Frequency  
120  
90  
kHz  
60  
MDU150 INPUT SPECIFICATIONS  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
36  
34  
20  
NOM  
MAX  
UNITS  
VDC  
VDC  
mS  
Input Voltage - DC  
Brown Out Protection  
Hold-up Time  
Continuous input range.  
Lowest DC input voltage that regulation is maintained with full rated loads.  
At 150 watts, over DC input range.  
75  
Input Current  
36 VDC at full rated load.  
Non-user serviceable internally located AC input line fuse.  
Vin = 72 VDC.  
Switching frequency of main output transformer.  
Switching frequency of secondary transformer.  
6.4  
35  
ARMS  
Input Protection  
Inrush Surge Current  
Operating Frequency  
APK  
kHz  
100  
70  
OUTPUT SPECIFICATIONS  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Efficiency  
Full Rated Load, 110 VAC. Varies with distribution of loads among outputs.  
65  
75  
%
Minimum Loads  
Minimum load required to maintain regulation on  
V2 at maximum load.  
MPU150-3300, V1  
All other models, V1  
4
3
A
Ripple and Noise  
Output Power  
Overshoot / Undershoot  
Regulation  
Full load, 20MHz bandwidth.  
With 300 LFM forced air cooling. (NOTE 1)  
Output voltage overshoot/undershoot at turn-on.  
Varies by output. Total regulation includes: line changes over the specified.  
input range, changes in load starting at 20% load and changing to 100% load.  
Recovery time, to within 1% of initial set point due to a 50-100% load change,  
5% max. deviation.  
See Model Selection Charts  
150  
Watts  
%
0
See Model Selection Charts  
500  
Transient Response  
µS  
Turn-on Delay  
Turn-on Rise Time  
Time required for initial output voltage stabilization.  
Time required for output voltage to rise from 10% to 90%.  
2
20  
Sec  
mS  
NOTES: 1) This product is not rated for convection applications.  
INTERFACE SIGNALS AND INTERNAL PROTECTION  
2
®
MPU/MDU150 SERIES  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Overvoltage Protection  
Latch style overvoltage protection. Available on  
V1, V2, all models, and V3 on all models except  
MPU150-3300.  
3.3V output, V1 4.1  
3.3V output, V2 3.8  
5V output, V1, V2 6.0  
4.65  
4.2  
6.4  
V
12V output, V2 (Note 1)  
14  
16  
MPU150-4350.  
3.3V output, V1 4.3  
4.65  
Overload Protection  
Overtemperature Protection  
Output Good  
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.  
System shutdown due to excessive internal temperature, automatic reset.  
TTL compatible signal available for V1. Signal is high when  
output is within 5% of nominal. Signal shall remain low for 20  
milliseconds following loss of Output Good.  
3.3V 3.16  
5V 4.75  
V
Input Power Fail Warning  
Current Share  
Remote Sense  
Inhibit  
TTL compatible logic signal. Time before regulation dropout due to loss of input  
power. May be used as independent PSOK signal in redundant applications.  
Accuracy of shared current with up to 6 parallel units. Single wire current share  
on V1 and V2 with return via -Sense return.  
Available on V1 and V2. Total voltage compensation for cable losses with  
respect to the main output.  
Output voltage is inhibited by application of an external high (5V) signal.  
5
mS  
%
10  
250  
mV  
NOTES: 1) Overvoltage range for 12V, V3 outputs: 14V to 19V.  
SAFETY, REGULATORY, AND EMI SPECIFICATIONS  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Agency Approvals  
UL1950.  
CSA 22.2 NO. 234/950.  
EN60950 (TÜV).  
Approved  
Dielectric Withstand Voltage  
Electromagnetic Interference  
Input to output per EN60950.  
MPU150 2600  
MDU150 1544  
VDC  
FCC CFR title 47 Part 15 Sub-Part J - Conducted.  
EN55022 / CISPR 22 Conducted.  
B
B
Class  
ESD Susceptibility  
Radiated Susceptibility  
EFT/Burst  
Per EN61000-4-2, level 4.  
Per EN61000-4-3, level 3.  
Per EN61000-4-4, level 3.  
Per EN61000-4-5, class 3.  
8
10  
2
1
2
kV  
V/M  
kV  
Input Transient Protection  
Line to Line  
Line to Ground  
kV  
Insulation Resistance  
Leakage Current  
Input to output.  
Per EN60950.  
10  
M  
MPU150 at 264 VAC  
MDU150 at 72 VDC  
1250  
100  
µA  
ENVIRONMENTAL SPECIFICATIONS  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Altitude  
Operating.  
Non-Operating.  
10k  
40k  
ASL Ft.  
ASL Ft.  
Operating Temperature  
At 100% load  
At 50% load  
0
0
50  
70  
°C  
°C  
Derate linearly above 50°C by 2.5% per °C.  
Storage Temperature  
Temperature Coefficient  
Relative Humidity  
Shock  
-55  
85  
0.05  
95  
20  
6
°C  
0°C to 70°C (after 15 minute warm-up).  
Non-Condensing.  
Peak acceleration.  
0.02  
%/°C  
%RH  
GPK  
5
Vibration  
Random vibration, 10Hz to 2kHz, 3 axis.  
GRMS  
OPTIONS  
DESCRIPTION  
NOTES  
SIZE IMPACT  
Metric Mounting  
Add “M” as a suffix to the model number to order chassis with  
M4 x 0.7 mounting inserts.  
8.00" x 4.20" x 1.50"  
(203.2mm x 106.7mm x 38.1mm)  
3
®
MPU/MDU150 SERIES  
OVERALL SIZE: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) WEIGHT: 2.0 LBS (0.89 kg)  
TRIPLE OUTPUT  
QUAD OUTPUT  
OUTPUTS:  
8-32 SCREW  
CONNECTIONS,  
4 PLACES  
+V1  
OUTPUTS:  
J2  
V1 & V2 RTN  
+V1  
RTN  
RTN  
+V3  
+V2  
J2  
J3  
+V3  
RTN  
V3 ADJ.  
J3  
V1,V.  
ADJ.  
V2,V.  
ADJ.  
J3  
V1 ADJ.  
V2 ADJ.  
J1  
J1  
+V3  
+ or L  
RTN  
+V2  
–V3  
+V4  
–V4  
INPUT  
- or N  
V4 ADJ.  
J300 INTERFACE CONNECTIONS  
PIN  
10. +S, V1  
9. –S, V1 & –S, V2  
8. CURRENT SHARE, V1  
7. +S, V2  
6. CURRENT SHARE, V2  
5. NO CONNECTION  
4. OUTPUT GOOD, V1  
3. POWER FAIL WARNING  
2. INHIBIT  
1. SIGNAL GROUND  
1.50"  
(38.1mm)  
0.75"  
(19.1mm)  
6-32 FLUSH NUT 8 PLACES (BOTH SIDES TYP.)  
WITH METRIC MOUNTING OPTION:  
M4 X 0.7, 8 PLACES. MAXIMUM TORQUE: 3.5 IN/LBS (0.40N/M)  
0.30"  
7.400" (188.0mm)  
8.00" (203.2mm)  
(7.6mm)  
±
0.23" 0.03"  
(5.7mm)  
0.75"  
(19.1mm)  
6.500" (165.1mm)  
4.20"  
(106.7mm)  
SUGGESTED AIR FLOW  
3.750"  
(95.3mm)  
MOLEX  
SERIES  
PIN  
PINS  
(LOOSE)  
PINS  
(CHAIN)  
WIRE  
GAUGE  
CONNECTOR  
HOUSING  
SERIES  
41695  
41695  
2139  
5051-N  
5051-N  
41695  
41695  
2139  
09-50-8051  
09-50-8051  
09-50-3051  
22-01-1022  
22-01-1022  
09-50-8021  
09-50-8021  
09-50-3021  
09-50-8061  
09-50-8061  
09-50-3061  
50-37-5103  
6838  
2478  
2478  
2759  
2759  
6838  
2478  
2478  
6838  
2478  
2478  
5263  
08-50-0189  
08-50-0106  
08-50-0106  
08-50-0114  
08-65-0805  
08-50-0189  
08-50-0106  
08-50-0106  
08-50-0189  
08-50-0106  
08-50-0106  
80-70-1040  
08-50-0187  
08-50-0105  
08-50-0105  
08-50-0113  
08-65-0804  
08-50-0187  
08-50-0105  
08-50-0105  
08-50-0187  
08-50-0105  
08-50-0105  
80-70-1039  
18-20AWG  
18-20AWG  
18-20AWG  
22-30AWG  
22-30AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
22-28AWG  
J1  
(ALL MODELS)  
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY,  
WITH CLEAR FINISH  
J2  
(TRIPLE OUTPUT)  
J3  
(TRIPLE OUTPUT)  
41695  
41695  
2139  
J3  
(QUAD OUTPUT)  
J300  
5264-N  
4

相关型号:

MDU150-4000M

AC-DC Power Factor Correction Module,
BEL

MDU150-4000MG

AC-DC Power Factor Correction Module,
BEL

MDU150-4230MG

AC-DC Power Factor Correction Module,
BEL

MDU150-4350G

AC-DC Power Factor Correction Module,
BEL

MDU150-4350M

AC-DC Power Factor Correction Module,
BEL

MDU150-4350MG

AC-DC Power Factor Correction Module,
BEL

MDU150-4530

Power Factor Correction (PFC) Meets EN61000-3-2
POWER-ONE

MDU150-4530G

DC-DC Regulated Power Supply Module, 4 Output, 150W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL

MDU150-4530M

AC-DC Power Factor Correction Module,
BEL

MDU150-4530MG

AC-DC Power Factor Correction Module,
BEL

MDU1511

Single N-channel Trench MOSFET 30V, 100.0A, 2.4m(ohm)
MGCHIP

MDU1511RH

Single N-channel Trench MOSFET 30V, 100.0A, 2.4m(ohm)
MGCHIP