Value Added Compact Flash Series Ⅲ
Specification for Industrial CF
Mar 8, 2011
Version 1.0
Apacer Technology Inc.
4th Fl., 75 Hsin Tai Wu Rd., Sec.1, Hsichih, New Taipei City, Taiwan 221
Tel: +886-2-2698-2888
www.apacer.com
Fax: +886-2-2698-2889
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Features:
ꢀ
Compact Flash Association
Specification Revision 3.0 Standard
Interface
ꢀ
ꢀ
Temperature ranges
–
–
Operation:
Standard: 0°C to 70°C
ET*: -40°C to 85°C
Storage: -40°C to 100°C
–
–
ATA command set compatible
ATA mode support for up to:
PIO Mode-6
Flash management
Multiword DMA Mode-4
Ultra DMA Mode-4
–
Intelligent endurance design
Advanced wear-leveling algorithms
S.M.A.R.T. Technology
ꢀ
ꢀ
Connector Type
–
50 pins female
Built-in Hardware ECC
Enhanced Data Integrity
Low power consumption (typical)
Supply voltage: 3.3V & 5V
–
Intelligent power failure recovery
–
–
–
Active mode: 80 mA/95 mA (3.3V/5.0V)
Sleep mode: 700 µA/900 µA (3.3V/5.0V)
ꢀ
RoHS compliant
ꢀ
ꢀ
Performance**
–
–
Sustained read: 30 MB/sec
Sustained write:
Standard: 5 MB/sec
High Speed: 15 MB/sec
Capacity
–
–
Standard:
128, 256, 512 MB
1, 2, 16 GB
High Speed:
256, 512 MB
1, 2, 4, 8 GB
ꢀ
NAND Flash Type: SLC
*Extended Temperature
**Performance varies with flash configurations
1
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Table of Contents
1. GENERAL DESCRIPTION ......................................................................................... 3
1.1 PERFORMANCE-OPTIMIZED
CONTROLLER ...............................................................................................3
1.1.1 Power Management Unit (PMU)...................................................................................................3
1.1.2 SRAM Buffer.................................................................................................................................3
2. FUNCTIONAL BLOCK ............................................................................................... 4
3. PIN ASSIGNMENTS................................................................................................... 5
4. CAPACITY SPECIFICATION ..................................................................................... 7
4.1 PERFORMANCE
SPECIFICATION ..............................................................................................................7
4.2 ENVIRONMENTAL
SPECIFICATIONS ..........................................................................................................8
5. FLASH MANAGEMENT ............................................................................................. 9
5.1 INTELLIGENT
ENDURANCE DESIGN..........................................................................................................9
5.1.1 Advanced wear-leveling algorithms..............................................................................................9
5.1.2 S.M.A.R.T. technology..................................................................................................................9
5.1.3 Built-in hardware ECC ..................................................................................................................9
5.1.4 Enhanced data integrity................................................................................................................9
5.2 INTELLIGENT
POWER FAILURE RECOVERY.............................................................................................10
6. SOFTWARE INTERFACE ....................................................................................... 11
6.1 COMMAND SET ....................................................................................................................................11
7. ELECTRICAL SPECIFICATION.............................................................................. 13
7.1 DC CHARACTERISTICS .........................................................................................................................14
7.2 AC CHARACTERISTICS .........................................................................................................................15
7.2.1 Attribute Memory Read Timing Specification .............................................................................16
7.2.2 Configuration Register (Attribute Memory) Write Specification..................................................17
7.2.3 Common Memory Read Timing Specification ............................................................................18
7.2.4 Common Memory Write Timing Specification ............................................................................19
7.2.5 I/O Input (Read) Timing Specification.........................................................................................20
7.2.6 I/O Output (Write) Timing Specification ......................................................................................21
7.2.7 Ultra DMA Mode Data Transfer Input/Output (Read/Write) Timing............................................22
7.2.8 Media Side Interface I/O Timing Specifications..........................................................................34
8. PHYSICAL CHARACTERISTICS............................................................................ 37
8.1 DIMENSION..........................................................................................................................................37
9. PRODUCT ORDERING INFORMATION................................................................. 38
9.1 PRODUCT
CODE DESIGNATIONS ...........................................................................................................38
9.2 VALID OMBINATIONS ..........................................................................................................................39
C
2
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
1. General Description
Apacer’s Industrial Compact Flash Card (CFC) offers the most reliable and high performance storage
which is compatible with CF Type I and Type II devise. Unlike the ordinary consumer Compact Flash
cards, Apacer Industrial Compact Flash card provides solid traceability to ensure all products HW/SW are
the same as you qualified.
Apacer’s CFC provides complete PCMCIA - ATA functionality and compatibility. Apacer ‘s Compact Flash
technology is designed for use in Point of Sale (POS) terminals, telecom, IP-STB, medical instruments,
surveillance systems, industrial PCs and handheld applications.
Featuring technologies as Advanced Wear-leveling algorithms, S.M.A.R.T, Enhanced Data Integrity, Built-
in Hardware ECC, and Intelligent Power Failure Recovery, Apacer’s Industrial Compact Flash Card
assures users of a versatile device on data storage.
1.1 Performance-Optimized Controller
The Compact Flash Card Controller translates standard CF signals into flash media data and control
signals.
1.1.1 Power Management Unit (PMU)
The power management unit (PMU) controls the power consumption of the Compact Flash card controller.
It reduces the power consumption of the Compact Flash Card Controller by putting circuitry not in
operation into sleep mode. The PMU has zero wake-up latency.
1.1.2 SRAM Buffer
The Compact Flash Card Controller performs as an SRAM buffer to optimize the host’s data transfer to
and from the flash media.
3
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
2. Functional Block
The Compact Flash Card (CFC) includes a controller and flash media, as well as the Compact Flash
standard interface. Figure 2-1 shows the functional block diagram.
Flash Array
Flash
Media
Flash
Media
Compact Flash
Controller
Compact Flash
Interface
Flash
Media
Flash
Media
Figure 2-1: Functional block diagram
4
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
3. Pin Assignments
Table 3-1 lists the pin assignments with respective signal names for the 50-pin configuration. A “#” suffix
indicates the active low signal. The pin type can be input, output or input/output.
Table 3-1: Pin assignments (1 of 2)
Pin No.
Memory card mode
I/O card mode
True IDE mode
Signal name Pin I/O type
Signal name
Pin I/O type
Signal name Pin I/O type
1
2
GND
D3
-
GND
D3
-
GND
D3
-
I/O
I/O
I/O
3
D4
I/O
D4
I/O
D4
I/O
4
D5
I/O
D5
I/O
D5
I/O
5
D6
I/O
D6
I/O
D6
I/O
6
D7
I/O
D7
I/O
D7
I/O
7
8
9
#CE1
A10
#OE
A9
A8
A7
VCC
A6
A5
A4
A3
A2
A1
A0
D0
D1
D2
WP
#CD2
#CD1
D11
D12
D13
D14
D15
#CE2
#VS1
#IORD
#IOWR
#WE
RDY/-BSY
VCC
#CSEL
#VS2
RESET
I
I
I
I
I
I
-
I
I
I
I
I
I
#CE1
A10
#OE
A9
A8
A7
VCC
A6
A5
A4
A3
A2
A1
A0
D0
D1
D2
#IOIS16
#CD2
#CD1
D11
D12
D13
D14
D15
#CE2
#VS1
#IORD
#IOWR
#WE
#IREQ
VCC
#CSEL
#VS2
RESET
I
I
I
I
I
I
-
I
I
I
I
I
I
#CS0
A101
#ATA SEL
A91
I
I
I
I
I
I
-
I
I
I
I
I
I
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
A81
A71
VCC
A61
A51
A41
A31
A2
A1
A0
D0
D1
D2
I
I
I
I/O
I/O
I/O
O
O
O
I/O
I/O
I/O
I/O
I/O
I
O
I
I
I
O
-
I/O
I/O
I/O
O
O
O
I/O
I/O
I/O
I/O
I/O
I
O
I
I
I
O
-
I/O
I/O
I/O
O
O
O
I/O
I/O
I/O
I/O
I/O
I
O
I
I
I
O
-
#IOCS16
#CD2
#CD1
D11
D12
D13
D14
D15
#CS1
#VS1
#IORD
#IOWR
#WE
INTRQ
VCC
#CSEL
#VS2
#RESET
I
O
I
I
O
I
I
O
I
5
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Table 3-1: Pin assignments (2 of 2)
Pin No.
Memory card mode
I/O card mode
True IDE mode
Signal name Pin I/O type
Signal name
Pin I/O type
Signal name Pin I/O type
42
43
44
45
46
47
48
49
50
#WAIT
#INPACK
#REG
BVD2
BVD1
D8
D9
D10
GND
O
O
I
O
O
I/O
I/O
I/O
-
#WAIT
#INPACK
#REG
#SPKR
#STSCHG
D8
O
O
I
O
O
I/O
I/O
I/O
-
IORDY
DMARQ2
DMACK2
#DASP
#PDIAG
D8
D9
D10
GND
O
O
I
O
O
I/O
I/O
I/O
-
D9
D10
GND
1. The signal should be grounded by the host.
2. Connection required when UDMA is in use.
6
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
4. Capacity Specification
Capacity specification of the Compact Flash Card series (CFC) is available as shown in Table 4-1. It lists
the specific capacity and the default numbers of heads, sectors and cylinders for each product line.
Table 4-1: Capacity specifications
Capacity
128 MB
256 MB
512 MB
1GB
Total bytes*
128,450,560
Cylinders
980
Heads
8
Sectors
32
Max LBA
250,880
256,901,120
980
16
32
501,760
512,483,328
993
16
63
1,000,944
2,001,888
4,001,760
8,027,712
16,007,040
32,014,080
1,024,966,656
2,048,901,120
4,110,188,544
8,195,604,480
16,391,208,960
1,986
3,970
7,964
15,880
16,383**
16
63
2GB
16
63
4GB
16
63
8GB
16
63
16GB
16
63
*Display of total bytes varies from file systems.
**Cylinders, heads or sectors are not applicable for these capacities. Only LBA addressing applies
4.1 Performance Specification
Performances of the Standard and High Speed ATA-Flash Disk are listed in Table 4-2 and Table 4-3.
Table 4-2: Standard Performance specifications
Capacity
128 MB / 256 MB
2 GB
16 GB
Performance
512 MB / 1 GB
15
20
5
20
5
Sustained read (MB/s)
Sustained write (MB/s)
5
Table 4-3: High Speed Performance specifications
Capacity 256 MB 512 MB
1 GB
2 GB
4 GB
8 GB
Performance
Sustained read (MB/s)
Sustained write (MB/s)
25
5
25
5
25
5
25
5
30
10
30
15
Note: Performance varies from flash configurations.
7
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
4.2 Environmental Specifications
Environmental specification of the Compact Flash Card series (CFC) which follows the MIL-STD-810F
standards is available as shown in Table 4-4.
Table 4-4: Environmental specifications
Environment
Specification
0°C to 70 ℃ (Standard) ; -40°C to 85 ℃ (Extended Temperature)
-40℃ to 100℃
Operation
Storage
Temperature
Humidity
5% to 95% RH (Non-condensing)
Vibration (Non-Operation)
Shock (Non-Operation)
Sine wave: 10~2000Hz, 15G (X, Y, Z axes)
Half sine wave, Peak acceleration 50 G, 11 ms (X, Y, Z ; All 6 axes)
8
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
5. Flash Management
5.1 Intelligent Endurance Design
5.1.1 Advanced wear-leveling algorithms
The NAND flash devices are limited by a certain number of write cycles. When using a file system,
frequent file table updates is mandatory. If some area on the flash wears out faster than others, it would
significantly reduce the lifetime of the whole device, even if the erase counts of others are far from the
write cycle limit. Thus, if the write cycles can be distributed evenly across the media, the lifetime of the
media can be prolonged significantly. The scheme is achieved both via buffer management and Apacer-
specific advanced wear leveling to ensure that the lifetime of the flash media can be increased, and the
disk access performance is optimized as well.
5.1.2 S.M.A.R.T. technology
S.M.A.R.T. is an acronym for Self-Monitoring, Analysis and Reporting Technology, an open standard
allowing disk drives to automatically monitor their own health and report potential problems. It protects the
user from unscheduled downtime by monitoring and storing critical drive performance and calibration
parameters. Ideally, this should allow taking proactive actions to prevent impending drive failure. Apacer
SMART feature adopts the standard SMART command B0h to read data from the drive. When the Apacer
SMART Utility running on the host, it analyzes and reports the disk status to the host before the device is
in critical condition.
5.1.3 Built-in hardware ECC
The ATA-Disk Module uses BCH Error Detection Code (EDC) and Error Correction Code (ECC)
algorithms which correct up to eight random single-bit errors for each 512-byte block of data. High
performance is fulfilled through hardware-based error detection and correction.
5.1.4 Enhanced data integrity
The properties of NAND flash memory make it ideal for applications that require high integrity while
operating in challenging environments. The integrity of data to NAND flash memory is generally
maintained through ECC algorithms and bad block management. Flash controllers can support up to 8
bits ECC capability for accuracy of data transactions, and bad block management is a preventive
mechanism from loss of data by retiring unusable media blocks and relocating the data to the other blocks,
along with the integration of advanced wear leveling algorithms, so that the lifespan of device can be
expanded.
9
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
5.2 Intelligent Power Failure Recovery
The Low Power Detection on the controller initiates cached data saving before the power supply to the
device is too low. This feature prevents the device from crash and ensures data integrity during an
unexpected blackout. Once power was failure before cached data writing back into flash, data in the
cache will lost. The next time the power is on, the controller will check these fragmented data segment,
and, if necessary, replace them with old data kept in flash until programmed successfully.
10
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
6. Software Interface
6.1 Command Set
Table 6-1 summarizes the command set with the paragraphs that follow describing the individual
commands and the task file for each.
Table 6-1: Command set (1 of 2)
Command
Check-Power-Mode
Code
E5H or 98H
90H
FR1
SC2
-
SN3
-
CY4
-
DH5
D8
D
Y
LBA6
-
-
-
-
Execute-Drive-Diagnostic
Erase Sector(s)
Flush-Cache
Format Track
Identify-Drive
Idle
-
-
-
C0H
-
Y
-
Y
-
Y
-
Y
-
E7H
-
D
Y8
D
D
D
Y
50H
-
Y7
-
Y
-
Y
-
ECH
-
-
-
E3H or 97H
E1H or 95H
91H
-
Y
-
-
-
-
Idle-Immediate
Initialize-Drive-Parameters
NOP
-
-
-
-
-
Y
-
-
-
-
00H
-
-
-
D
D
Y
-
Read-Buffer
E4H
-
-
-
-
-
Read-DMA
C8H or C9H
C4H
-
Y
Y
Y
Y
-
Y
Y
Y
Y
-
Y
Y
Y
Y
-
Y
Y
Y
Y
-
Read-Multiple
Read-Sector(s)
Read-Verify-Sector(s)
Recalibrate
-
Y
20H or 21H
40H or 41H
1XH
-
Y
-
Y
-
D
D
Y
Request-Sense
Seek
03H
-
-
-
-
-
7XH
-
Y7
-
Y
-
Y
-
Y
-
Set-Features
EFH
-
D
11
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Table 6-1: Command set (2 of 2)
Command
Code
B0H
FR1
SC2
Y
Y
-
SN3
Y
-
CY4
Y
-
DH5
D
D
D
D
D
Y
LBA6
SMART
Y
-
-
-
-
-
-
-
-
-
-
-
-
Set-Multiple-Mode
Set-Sleep-Mode
Standby
C6H
-
-
E6H or 99H
E2H or 96H
E0H or 94H
87H
-
-
-
-
-
-
Standby-lmmediate
Translate-Sector
Write-Buffer
-
-
-
-
Y
-
Y
-
Y
-
Y
-
E8H
D
Y
Write-DMA
CAH or CBH
C5H
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Write-Multiple
Y
Write-Multiple-Without-Erase
Write-Sector(s)
Write-Sector-Without-Erase
Write-Verify
CDH
Y
30H or 31H
38H
Y
Y
3CH
Y
1. FR - Features register
2. SC - Sector Count register
3. SN - Sector Number register
4. CY - Cylinder registers
5. DH - Drive/Head register
6. LBA - Logical Block Address mode supported (see command descriptions for use)
7. Y - The register contains a valid parameter for this command
8. For the Drive/Head register:
Y means both the CFC and Head parameters are used
D means only the CFC parameter is valid and not the Head parameter
12
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
7. Electrical Specification
Caution: Absolute Maximum Stress Ratings – Applied conditions greater than those listed under
“Absolute Maximum Stress Ratings” may cause permanent damage to the device. This is a stress rating
only and functional operation of the device at these conditions or conditions greater than those defined in
the operational sections of this data sheet is not implied. Exposure to absolute maximum stress rating
conditions may affect device reliability.
Table 7-1: Operating range
Range
Ambient Temperature
0°C to +70°C
3.3V
5V
Standard
3.135-3.465V
4.75-5.25V
Extended Temperature
-40°C to +85°C
Table 7-2: Absolute maximum power pin stress ratings
Parameter
Symbol
VDD
Conditions
Input Power
-0.3V min. to 6.5V max.
-0.5V min. to VDD + 0.5V max.
Voltage on any pin except VDD with respect to GND
V
Table 7-3: Recommended system power-up timing
Symbol
Parameter
Typical
200
Maximum
Units
ms
1
TPU-READY
Power-up to Ready Operation
Power-up to Write Operation
1000
1000
1
TPU-WRITE
200
ms
1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter.
13
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
7.1 DC Characteristics
Table 7-4: DC Characteristics
Symbol
VIH1
VIL1
Type
Parameter
Input Voltage
Min
2.0V
Max
Units
Conditions
VDDQ=VDDQ Max
VDDQ=VDDQ Min
V
I1
0.8V
10
Input Leakage Current
Input Pull-Up Current
-10
A
μ
VIN=GND to VDDQ
VDDQ= VDDQ Max
VOUT=GND,
VDDQ= VDDQ Max
VDDQ=VDDQ Max
VDDQ=VDDQ Min
IIL1
I1Z
I1U
-110
-1
A
μ
IU1
Input Voltage Schmitt Trigger
2.0
V
VT+2
VT-2
I2
0.8
-10
Input Leakage Current
Input Pull-Up Current
Output Voltage
10
-1
A
μ
VIN=GND to VDDQ
VDDQ= VDDQ Max
VOUT=GND,
VDDQ= VDDQ Max
IOH1=IOH1 Min
IOL1=IOL1 Max
IIL2
IU2
I2Z
I2U
-110
2.4
A
μ
V
VOH1
VOL1
IOH1
IOL1
VOH2
VOL2
IOH2
IOL2
IOH2
IOL2
VOH6
VOL6
IOH6
IOL6
0.4
O1
Output Current
Output Current
Output Voltage
-4
mA
mA
V
VDDQ=VDDQ Min
VDDQ=VDDQ Min
4
2.4
-6
IOH2=IOH2 Min
IOL2=IOL2 Max
0.4
Output Current
mA
mA
mA
mA
V
VDDQ=3.135V-3.465V
VDDQ=3.135V-3.465V
VDDQ=4.5V-5.5V
O2
Output Current
6
Output Current
-8
Output Current
8
VDDQ=4.5V-5.5V
Output Voltage for DASP# pin
2.4
-3
IOH6=IOH6 Min
IOL6=IOL6 Max
0.4
Output Current for DASP# pin
Output Current for DASP# pin
Output Current for DASP# pin
Output Current for DASP# pin
Power supply current
(T = 0°C to +70°C)
a
Power supply current
(T = -40°C to +85°C)
a
Sleep/Standby/Idle current
mA
mA
mA
mA
mA
VDDQ=3.135V-3.465V
VDDQ=3.135V-3.465V
VDDQ=4.5V-5.5V
O6
8
-3
IOH6
IOL6
12
50
VDDQ=4.5V-5.5V
1,2
VDD=VDD Max
VDDQ=VDDQ Max
VDD=VDD Max
VDDQ=VDDQ Max
VDD=VDD Max
VDDQ=VDDQ Max
IDD
PWR
PWR
PWR
1,2
IDD
75
75
mA
A
μ
ISP
ISP
(T = 0°C to +70°C)
a
200
A
μ
VDD=VDD Max
VDDQ=VDDQ Max
Sleep/Standby/Idle current
(T = -40°C to +85°C)
a
PWR
14
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
7.2 AC Characteristics
Figure 7-1: AC Input/Output Reference Waveforms
AC test inputs are driven at VIHT (0.9 VDD) for a logic “1” and VILT (0.1 VDD) for a logic “0”.
Measurement reference points for inputs and outputs are VIT (0.5 VDD) and VOT (0.5 VDD). Input rise
and fall times (10% ↔ 90%) are <10 ns.
Note: VIT - VINPUT Test
VOT - VOUTPUT Test
VIHT - VINPUT HIGH Test
VILT- VINPUT LOW Test
15
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
7.2.1 Attribute Memory Read Timing Specification
The Attribute Memory access time is defined as 100 ns. Detailed timing specifications are shown in the
table below.
Table 7-5: Attribute Memory Read Timing Specification
Speed Version
Item
Read Cycle Time
100 ns
Max*
Symbol
TC(R)
IEEE Symbol
tAVAV
Min*
100
Units
ns
Address Access Time
TA(A)
tAVQV
tELQV
tGLQV
tEHQZ
tGHQZ
tAVGL
tELQNZ
tGLQNZ
tAXQZ
100
100
50
50
50
ns
ns
ns
ns
ns
ns
ns
ns
Card Enable Access Time
Output Enable Access Time
Output Disable Time from CE#
Output Disable Time from OE#
Address Setup Time
Output Enable Time from CE#
Output Enable Time from OE#
Data Valid from Address Change
TA(CE)
TA(OE)
TDIS(CE)
TDIS(OE)
TSU(A)
TEN(CE)
TEN(OE)
TV(A)
10
5
5
0
ns
*DOUT signifies data provided by the Compact Flash card to the system. The CE# signal or both the OE# signal and the WE# signal
must be de-asserted between consecutive cycle operations. All AC specifications are guaranteed by design.
Figure 7-2: Attribute Memory Read Timing Diagram
16
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
7.2.2 Configuration Register (Attribute Memory) Write Specification
The card configuration write access time is defined as 100 ns. Detailed timing specifications are shown in
the table below.
Table 7-6: Configuration Register (Attribute Memory) Write Timing
Speed Version
Item
100 ns
Max*
Symbol
TC(W)
TW(WE)
TSU(A)
TREC(WE)
TSU(DWE#H) tDVWH
TH(D) tWMDX
IEEE Symbol
tAVAV
tWLWH
tAVWL
tWMAX
Min*
100
60
10
15
Units
ns
ns
ns
ns
Write Cycle Time
Write Pulse Width
Address Setup Time
Write Recover Time
Data Setup Time for WE
Data Hold Time
40
15
ns
ns
*DIN signifies data provided by the system to the Compact Flash card. All AC specifications are guaranteed by design.
Figure 7-3: Configuration Register (Attribute Memory) Write Timing Diagram
17
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
7.2.3 Common Memory Read Timing Specification
Table 7-7: Common Memory Read Timing
Item
Symbol
TA(OE)
TDIS(OE)
TSU(A)
TREC(WE)
TSU(CE)
TH(CE)
IEEE Symbol
tGLQV
tGHQZ
tAVGL
tGHAX
Min*
Max*
50
50
Units
ns
ns
ns
ns
Output Enable Access Time
Output Disable Time from OE
Address Setup Time
Address Hold Time
CE Setup before OE
CE Hold following OE
10
15
0
tELGL
tGHEH
ns
ns
15
*All AC specifications are guaranteed by design.
Figure 7-4: Common Memory Read Timing Diagram
18
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
7.2.4 Common Memory Write Timing Specification
Table 7-8: Common Memory Write Timing
Symbol IEEE Symbol
TSU(DWE#H) tDVWH
Item
Min*
40
15
60
10
0
15
15
15
Max*
Units
ns
ns
ns
ns
ns
ns
ns
ns
Data Setup before WE
Data Hold following WE
WE Pulse Width
Address Setup Time
CE Setup before WE
Write Recovery Time
Address Hold Time
CE Hold following WE
TH(D)
tWMDX
tWLWH
tAVWL
tELWL
tWMAX
tGHAX
tGHEH
TW(WE)
TSU(A)
TSU(CE)
TREC(WE)
TH(A)
TH(CE)
*All AC specifications are guaranteed by design.
Figure 7-5: Common Memory Write Timing Diagram
19
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
7.2.5 I/O Input (Read) Timing Specification
Table 7-9: I/O Read Timing
Item
Symbol
TD(IORD)
TH(IORD)
TW(IORD)
TSUA(IORD)
THA(IORD)
TSUCE(IORD)
THCE(IORD)
TSUREG(IORD)
THREG(IORD)
TDFINPACK(IORD)
TDRINPACK(IORD)
IEEE Symbol
tlGLQV
tlGHQX
tlGLIGH
tAVIGL
Min*
Max*
100
Units
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Data Delay after IORD
Data Hold following IORD
IORD Width Time
0
165
70
20
5
20
5
0
Address Setup before IORD
Address Hold following IORD
CE Setup before IORD
CE Hold following IORD
REG Setup before IORD
REG Hold following IORD
INPACK Delay Falling from IORD
INPACK Delay Rising from IORD
tlGHAX
tELIGL
tlGHEH
tRGLIGL
tlGHRGH
tlGLIAL
tlGHIAH
tAVISL
0
45
45
35
35
IOIS16 Delay Falling from Address TDFIOIS16(ARD)
IOIS16 Delay Rising from Address
*All AC specifications are guaranteed by design.
TDRIOIS16(ADR)
tAVISH
Note: The maximum load on –INPACK and IOIS16# is 1 LSTTL with 50pF total load.
Figure 7-6: I/O Read Timing Diagram
20
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
7.2.6 I/O Output (Write) Timing Specification
Table 7-10: I/O Write Timing
Item
Symbol
TSU(IOWR)
TH(IOWR)
IEEE Symbol
tDVIWH
tlWHDX
tlWLIWH
tAVIWL
tlWHAX
tELIWL
tlWHEH
tRGLIWL
tlWHRGH
tAVISL
Min*
60
30
165
70
20
5
20
5
0
Max*
Units
ns
ns
ns
ns
ns
ns
ns
ns
Data Setup before IOWR
Data Hold following IOWR
IOWR Width Time
Address Setup before IOWR
Address Hold following IOWR
CE Setup before IOWR
CE Hold following IOWR
REG Setup before IOWR
REG Hold following IOWR
TW(IOWR)
TSUA(IOWR)
THA(IOWR)
TSUCE(IOWR)
THCE(IOWR)
TSUREG(IOWR)
THREG(IOWR)
ns
ns
ns
IOIS16 Delay Falling from Address TDFIOIS16(ARD)
IOIS16 Delay Rising from Address
*All AC specifications are guaranteed by design.
35
35
TDRIOIS16(ADR)
tAVISH
Note: The maximum load on –INPACK and IOIS16# is 1 LSTTL with 50pF total load.
Figure 7-7: I/O Write Timing Diagram
21
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
7.2.7 Ultra DMA Mode Data Transfer Input/Output (Read/Write) Timing
Table 7-11: Ultra DMA Data Burst Timing Specifications1
Mode 4
Measurement
Location2
Sender
Name
Descriptions
Unit
Min
60
Max
T2CYCTYP Typical sustained average two cycle time
T CYC
ns
ns
Cycle time allowing for asymmetry and clock
variations (from STROBE edge to STROBE
edge)
25
Note3
T 2CYC
Two cycle time allowing for clock variations
(from rising edge to next rising edge or from
falling edge to next falling edge of STROBE)
Data setup time at recipient (from data valid until
STROBE edge)4,5
57
ns
Sender
T DS
5.0
5.0
6.0
6.0
ns
ns
ns
ns
Recipient
Recipient
Sender
T DH
Data hold time at Recipient (from STROBE edge
until data becomes invalid)1,2
T DVS
T DVH
Data valid setup time for Sender (from data valid
until STROBE edge)6
Data valid hold time at Sender (from STROBE
Sender
edge until data becomes invalid)3
T CS
T CH
T CVS
CRC word setup time at device1
5.0
5.0
6.7
ns
ns
ns
Device
Device
Host
CRC word hold time at device1
CRC word valid setup time at host (from CRC
valid until DMACK negation)3
T CVH
T ZFS
T DZFS
T FS
CRC word valid hold time at Sender (from
DMACK negation until CRC becomes invalid)3
Time from STROBE output released-to-driving
until the first transition of critical timing
Time from data output released-to-driving until
the first transition of critical timing
6.2
0
ns
ns
ns
ns
Host
Device
Sender
Device
6.7
First STROBE time (for device to first negate
DSTROBE from STOP during a data in burst)
Limited interlock time7
120
100
T LI
0
20
0
ns
ns
ns
ns
Note8
Host
Host
Note9
T MLI
T UI
T AZ
Interlock time with minimum4
Unlimited interlock time4
Maximum time allowed for output drivers to
release (from asserted to negated)
Minimum delay time required for output
Drivers to assert or negate (from released)
Envelope time (from DMACK# to STOP and
HDMARDY# during data in burst initiation and
from DMACK to STOP during data our burst
initiation)
Ready-to-final STROBE time (no STROBE edge
are sent this long after negation of DMARDY)
Ready-to-pause time (Recipient waits to pause
until after negating DMARDY)
10
55
60
20
T ZAH
T ZAD
T ENV
20
0
20
ns
ns
ns
Host
Device
Host
T RFS
T RP
ns
ns
Sender
100
Recipient
T IORDYZ
T ZIORDY
T ACK
Maximum time before releasing IORDY
ns
ns
ns
ns
Device
Device
Host
Minimum time before driving IORDY10
0
20
50
T SS
Sender
22
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
1. All timing measurement switching points (low-to-high and high-to-low) are taken at 1.5V.
2. All signal transitions for a timing parameter are measured at the connector specified in the measurement location column. For
example, in the case of TRFS, both STROBE and DMARDY Transitions are measured at the Sender connector.
3. The parameter TCYC is measured at the recipient’s connector farthest from the Sender.
4. 80-Conductor cabling is required in order to meet sup (TDS, TCS) and hold (TDH, TCH) times in modes greater than two.
5. The parameters TDS and TDH for Mode 5 are defined for a Recipient at the end of the cable only in a configuration with a single
device located at the end of the cable. This could result in the minimum values for TDS and TDH for mode 5 at the middle
connector being 3.0 and 3.9 ns respectively.
6. Timing for TDVS, TDVH, TCVS, and TCVH are met for lumped capacitive loads of 15 and 50 pf at the connector where the Data
and STROBE signals have the same capacitive load value. Due to reflections on the cable, these timing measurements are not
valid in a normally functioning system.
7. The parameters TUI, TMLI, and TLI indicate Sender-to-Recipient or Recipient-to-Sender interlocks. For example, one agent
(either Sender or Recipient) is waiting for the other agent to respond with a signal before proceeding; TUI is an unlimited
interlock that has no maximum time value, TMLI is a limited time-out that has a defined minimum, and TLI is a limited time-out
that has a defined maximum.
8. The parameter TLI is measured at the connector of the Sender or Recipient that is responding to an incoming transition from the
Recipient or Sender respectively. Both the incoming signal and the outgoing response are measured at the same connector.
9. The parameter TAZ is measured at the connector of the Sender or Recipient that is driving the bus but must release the bus that
allow for a bus turnaround.
10. For all modes the parameter TZIORDY may be greater than TENV because the host has a pull-on IORDY giving it a known
state when released.
23
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Table 7-12: Ultra DMA Sender and Recipient IC Timing Specifications1
Mode 4
Name
Descriptions
Unit
Min
4.8
4.8
Max
TDSIC
T DHIC
Recipient IC data setup time (from data valid until STROBE edge)2
Recipient IC data hold time (from STROBE edge until data becomes
invalid)1
ns
ns
T DVSIC
T DVHIC
Sender IC data valid setup time (from data valid until STROBE edge)3
9.5
9.0
ns
ns
1.
2.
All timing measurement switching point (low-to-high and high-to-low)
The correct data value is captured by the Recipient given input data with a slew rate of 0.4 V/ns rising and falling and the input
STROBE with a slew rate of 0.4 V/ns rising and falling at TDSIC and TDHIC timing (as measured through 1.5 V).
The parameters TDVSIC and TDVHIC are met for lumped capacitive loads of 15 and 40 pf at the IC where all signals have the
same capacitive load value. Noise that may couple onto the output signals from external sources has not been included in
these values.
3.
Figure 7-8: Initiating an Ultra DMA Data-In Burst
Notes:
1.
The definitions for the DIOW-:STOP, DIOR-:HDMARDY-:HSTROBE, and IORDY:DDRARDY-: DSTROBE signal lines are not
in effect until DMARQ and DMACK are asserted.
24
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Figure 7-9: Sustained Ultra DMA Data-In Burst
Notes:
1.
DD(15:0) and DSTROBE signals are shown at both the host and the device to emphasize that cable settling time as well as
cable propagation delay will not allow the data signals to be considered stable at the host until some time after they are driven
by the device.
25
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Figure 7-10: Sustained Ultra DMA Data-In Burst
Notes:
1.
2.
The host may assert STOP to request termination of the Ultra DMA burst no sooner than TRP after HDMARDY# is negated.
After negating HDMARDY#, the host may receive zero, one, two, or three more data words from the device.
26
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Figure 7-11: Device Terminating and Ultra DMA Data-In Burst
Notes:
1.
The definitions for the STOP, HDMARDY, and DSTROBE signal lines are no longer in effect after DMARQ and DMACK are
negated.
27
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Figure 7-12: Host Terminating and Ultra DMA Data-In Burst
Notes:
1.
The definitions for the STOP, HDMARDY, and DSTROBE signal lines are no longer in effect after DMARQ and DMACK are
negated.
28
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Figure 7-13: Initiating an Ultra DMA Data-Out Burst
Notes:
1.
The definitions for the STOP, DDMARDY, and HSTROBE signal lines are no longer in effect after DMARQ and DMACK are
negated.
29
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Figure 7-14: Sustained Ultra DMA Data-Out Burst
Notes:
1.
DD(15:0) and HSTROBE signals are shown at both the host and the device to emphasize that cable settling time as well as
cable propagation delay will not allow the data signals to be considered stable at the host until some time after they are driven
by the host.
30
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Figure 7-15: Device Pausing and Ultra DMA Data-Out Burst
Notes:
1.
2.
The host may negate DMARQ to request termination of the Ultra DMA burst no sooner than TRP after DDMARDY# is negated.
After negating DDMARDY#, the host may receive zero, one, two, or three more data words from the host.
31
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Figure 7-16: Host Terminating and Ultra DMA Data-Out Burst
Notes:
1. The definitions for the STOP, DDMARDY, and HSTROBE signal lines are no longer in effect after DMARQ and DMACK are
negated.
32
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Figure 7-17: Device Terminating and Ultra DMA Data-Out Burst
Notes:
1.
The definitions for the STOP, DDMARDY, and HSTROBE signal lines are no longer in effect after DMARQ and DMACK are
negated.
33
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
7.2.8 Media Side Interface I/O Timing Specifications
Table 7-13: Timing Parameter
Symbol
TCLS
TCLH
TCS
TCH
TCHR
TWP
TWH
TWC
TALS
TALH
TDS
TDH
TRP
TRR
TRES
TRC
Parameter
FCLE Setup Time
FCLE Hold Time
FCE# Setup Time
FCE# Hold Time for Command/Data Write Cycle
FCE# Hold Time for Sequential Read Last Cycle
FWE# Pulse Width
FWE# High Hold Time
Write Cycle Time
FALE Setup Time
FALE Hold Time
FAD[15:0] Setup Time
FAD[15:0] Hold Time
FRE# Pulse Width
Ready to FRE# Low
FRE# Data Setup Access Time
Read Cycle Time
FRE# High Hold Time
FRE# High to Data Hi-Z
Min
20
40
40
40
-
20
20
40
20
40
20
20
20
40
20
40
20
5
Max
Units
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
-
-
-
-
40
-
-
-
-
-
-
-
-
-
-
-
-
-
TREH
TRHZ
Note: All AC specifications are guaranteed by design.
34
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Figure 7-18: Media Command Latch Cycle
Figure 7-19: Media Access Latch Cycle
35
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Figure 7-20: Media Data Loading Latch Cycle
Figure 7-21: Media Data Read Cycle
36
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
8. Physical Characteristics
8.1 Dimension
T
ABLE 8-1: Type I CFC physical specification
36.40 +/- 0.15mm (1.433+/- 0.06 in.)
42.80 +/- 0.10mm (1.685+/- 0.04 in.)
3.3mm+/-0.10mm (0.130+/-0.04in.)
Length:
Width:
Thickness (Including Label Area):
Unit: mm
F
IGURE 8-1: Physical dimension
37
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
9. Product Ordering Information
9.1 Product Code Designations
A P – C F x x x x E 3 X R – XXXXXXK
Specification
NR: Non-Removable Setting
NDNR: Non-DMA + Non-Removable
ETNR: Ext. Temp. + Non-Removable
ETNDNR: Ext. Temp + Non-DMA + Non-Removable
K: Value Added Ⅲ
RoHS Compliant
Configuration
E: Standard
F: High Speed
Controller Type
CFC Type
Capacity:
128M: 128MB
256M: 256MB
512M: 512MB
001G:
002G:
004G:
008G:
016G:
1GB
2GB
4GB
8GB
16GB
Model Name
Apacer Product Code
38
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
9.2 Valid Combinations
Standard Temperature
Non-Removable
Standard
High Speed
Capacity
256MB
512MB
1GB
Capacity
128MB
256MB
512MB
1GB
Model Number
Model Number
AP-CF256ME3FR-NRK
AP-CF512ME3FR-NRK
AP-CF001GE3FR-NRK
AP-CF002GE3FR-NRK
AP-CF004GE3FR-NRK
AP-CF008GE3FR-NRK
AP-CF128ME3ER-NRK
AP-CF256ME3ER-NRK
AP-CF512ME3ER-NRK
AP-CF001GE3ER-NRK
AP-CF002GE3ER-NRK
AP-CF016GE3ER-NRK
2GB
2GB
4GB
16GB
8GB
Non-DMA & Non-Removable
Standard
High Speed
Capacity
256MB
512MB
1GB
Capacity
128MB
256MB
512MB
1GB
Model Number
Model Number
AP-CF128ME3ER-NDNRK
AP-CF256ME3ER-NDNRK
AP-CF512ME3ER-NDNRK
AP-CF001GE3ER-NDNRK
AP-CF002GE3ER-NDNRK
AP-CF016GE3ER-NDNRK
AP-CF256ME3FR-NDNRK
AP-CF512ME3FR-NDNRK
AP-CF001GE3FR-NDNRK
AP-CF002GE3FR-NDNRK
AP-CF004GE3FR-NDNRK
AP-CF008GE3FR-NDNRK
2GB
2GB
4GB
16GB
8GB
39
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Extended Temperature
Non-Removable
Standard
High Speed
Capacity
256MB
512MB
1GB
Capacity
Model Number
Model Number
128MB
256MB
512MB
1GB
AP-CF128ME3ER-ETNRK
AP-CF256ME3ER-ETNRK
AP-CF512ME3ER-ETNRK
AP-CF001GE3ER-ETNRK
AP-CF002GE3ER-ETNRK
AP-CF016GE3ER-ETNRK
AP-CF256ME3FR-ETNRK
AP-CF512ME3FR-ETNRK
AP-CF001GE3FR-ETNRK
AP-CF002GE3FR-ETNRK
AP-CF004GE3FR-ETNRK
AP-CF008GE3FR-ETNRK
2GB
2GB
4GB
16GB
8GB
Non-DMA & Non-Removable
Standard
High Speed
Capacity
256MB
512MB
1GB
Capacity
128MB
256MB
512MB
1GB
Model Number
Model Number
AP-CF128ME3ER-ETNDNRK
AP-CF256ME3ER-ETNDNRK
AP-CF512ME3ER-ETNDNRK
AP-CF001GE3ER-ETNDNRK
AP-CF002GE3ER-ETNDNRK
AP-CF016GE3ER-ETNDNRK
AP-CF256ME3FR-ETNDNRK
AP-CF512ME3FR-ETNDNRK
AP-CF001GE3FR-ETNDNRK
AP-CF002GE3FR-ETNDNRK
AP-CF004GE3FR-ETNDNRK
AP-CF008GE3FR-ETNDNRK
2GB
2GB
4GB
16GB
8GB
40
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Revision History
Revision
Description
Date
1.0
Official release
Mar 8, 2011
41
© 2011 Apacer Technology Inc.
Rev. 1.0
Value Added Compact Flash Ⅲ series
AP-CFxxxxE3XR-XXXXXXK
Global Presence
Apacer Technology Inc.
Taiwan (Headquarters)
4th Fl, 75 Xintai 5th Rd., Sec.1
Hsichih, New Taipei City
Taiwan 221
R.O.C.
Tel: +886-2-2698-2888
Fax: +886-2-2698-2889
amtsales@apacer.com
Apacer Memory America, Inc.
386 Fairview Way, Suite102,
Milpitas, CA 95035
Tel: 1-408-518-8699
Fax: 1-408-935-9611
U.S.A.
Japan
Europe
sa@apacerus.com
Apacer Technology Corp.
5F, Matsura Bldg., Shiba, Minato-Ku
Tokyo, 105-0014, Japan
Tel: 81-3-5419-2668
Fax: 81-3-5419-0018
jpservices@apacer.com
Apacer Technology B.V.
Aziëlaan 22,
5232 BA 's-Hertogenbosch,
The Netherlands
Tel: 31-73-645-9620
Fax: 31-73-645-9629
sales@apacer.nl
Apacer Electronic (Shanghai) Co., Ltd
1301, No.251,Xiaomuqiao Road, Shanghai,
200032, China
Tel: 86-21-5529-0222
Fax: 86-21-5206-6939
China
India
sales@apacer.com.cn
Apacer Technologies Pvt Ltd,
#1064, 1st Floor, 7th ‘A’ Main,
3rd Block Koramangala, Bangalore – 560 034
Tel: +91 80 4152 9061/62/63
Fax: +91 80 4170 0215
sales_india@apacer.com
42
© 2011 Apacer Technology Inc.
Rev. 1.0
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Apacer:
AP-CF001GE3FR-ETNDNRK AP-CF001GE3FR-ETNRK AP-CF001GE3FR-NDNRK AP-CF001GE3FR-NRK AP-
CF001GH4FR-ETNDNRK AP-CF001GH4FR-ETNRK AP-CF001GH4FR-NDNRK AP-CF001GH4FR-NRK AP-
CF002GE3FR-ETNDNRK AP-CF002GE3FR-ETNRK AP-CF002GE3FR-NDNRK AP-CF002GE3FR-NRK AP-
CF002GH4FR-ETNDNRK AP-CF002GH4FR-ETNRK AP-CF002GH4FR-NDNRK AP-CF002GH4FR-NRK AP-
CF004GE3FR-ETNDNRK AP-CF004GE3FR-ETNRK AP-CF004GE3FR-NDNRK AP-CF004GE3FR-NRK AP-
CF004GH4FR-ETNDNRK AP-CF004GH4FR-ETNRK AP-CF004GH4FR-NDNRK AP-CF004GH4FR-NRK AP-
CF008GE3FR-ETNDNRK AP-CF008GE3FR-ETNRK AP-CF008GE3FR-NDNRK AP-CF008GE3FR-NRK AP-
CF008GH4FR-ETNDNRK AP-CF008GH4FR-ETNRK AP-CF008GH4FR-NDNRK AP-CF128ME3ER-ETNDNRK AP-
CF128ME3ER-ETNRK AP-CF128ME3ER-NDNRK AP-CF128ME3ER-NRK AP-CF128MH4ER-ETNDNRK AP-
CF128MH4ER-ETNRK AP-CF128MH4ER-NDNRK AP-CF128MH4ER-NRK AP-CF256ME3FR-NDNRK AP-
CF256ME3FR-NRK AP-CF256MH4FR-ETNDNRK AP-CF256MH4FR-ETNRK AP-CF256MH4FR-NDNRK AP-
CF256MH4FR-NRK AP-CF512ME3FR-ETNDNRK AP-CF512ME3FR-ETNRK AP-CF512ME3FR-NDNRK AP-
CF512ME3FR-NRK AP-CF512MH4FR-ETNDNRK AP-CF512MH4FR-ETNRK AP-CF512MH4FR-NDNRK AP-
CF512MH4FR-NRK
相关型号:
©2020 ICPDF网 联系我们和版权申明