TRC-150S035ST [ETC]
Switch Mode LED Drivers;150W TRC-150 Series
Switch Mode LED Drivers
Constant Current
Aluminum Housing
Electrical Specifications
Input Voltage Range:
100 - 277 Nom. Vac (90 - 305 V Min/Max)
Frequency:
50/60 Hz Nom. (47-63 Hz Min/Max)
>0.90 @ full load, 100V through 277V
Power Factor:
Inrush Current:
Input Current:
65 Amps max @ 230 Vac, cold start 25ºC
1.8 A max 100Vac, 0.9 A max 220Vac
Maximum Power:
Line Regulation:
Load Regulation:
Leakage Current:
Typical Efficiency
Turn-on Delay:
Ripple and Noise:
Protection:
150W
± 1%
± 3%
1 mA 277 VAC 60Hz
89-91% at 277VAC
0.5S typical 110Vac, 0.3S typical 220Vac
3% Vo
• Total Power: 150 Watts
• Input Voltage: 100-277 Vac Nom.
• UL Dry & Damp Location Rated
• IP67
• Ultra-high Efficiency
• High Power Factor with Active Correction
• UL8750
Over-Voltage, Over-Temperature (110°C), Lightning,
and Short Circuit Protection with Self Recovery
Environmental Specifications
Max Case Temperature:
350mA, 450mA, 700mA Tc= 88.2ºC, all others Tc= 90ºC
Storage Temperature:
-40ºC to +85ºC
Minimum Starting Temp: -35ºC
Humidity:
Cooling:
5% to 100%
Convection
Class A
Sound Rating:
MTBF:
- 250,000 Hrs (350mA model) @110Vac input, 80% load,
25ºC ambient conditions per MIL-HDBK-217F
- 195,000 Hrs (5950mA model) @110Vac input, 80% load,
25ºC ambient conditions per MIL-HDBK-217F
Lifetime:
Weight:
- 90,000 Hrs (350mA model) @ 220Vac, 80% load,
60ºC case temp.
- 50,000 Hrs (5950mA model) @ 220Vac, 80% load,
60ºC case temp.
3.31 lbs. (1.5 kg)
Constant Current - Product Specifications
New Surge Protection and HI-POT Testing
Output Current Output Voltage Max Output
Typical
Model Name
(mA)*
350
Range (Vdc)
256-428
200-333
128-214
85-142
64-107
51-85
Power (W) Efficiency
TRC-150S035ST
TRC-150S045ST
TRC-150S070ST
TRC-150S105ST
TRC-150S140ST
TRC-150S175ST
TRC-150S210ST
TRC-150S245ST
TRC-150S280ST
TRC-150S315ST
TRC-150S350ST
TRC-150S420ST
TRC-150S490ST
TRC-150S595ST
150
150
150
150
150
150
150
150
150
150
150
150
150
150
92%
92%
92%
92%
92%
91%
91%
90%
90%
90%
90%
89%
89%
88%
450
700
Metal Lock Sheet
Nut
1050
1400
1750
2100
2450
2800
3150
3500
4200
4900
5950
HI-POT Test
Normal Application
42-71
The new design of this LED driver provides 1.4KV surge protection. To properly
HI-POT test this unit, the surge protection must be disconnected. The screw, nut, and
metal lock sheet on the input side of the driver provide for this. To test, first remove
the nut and lock sheet as shown. After testing, secure the nut and lock sheet to
provide line-to-earth protection.
36-61
31-53
28-47
25-42
This HI-POT test feature is available on product manufactured after August 15, 2015.
21-35
18-30
15-25
* The output current is adjustable at factory from 50% to 100%.
E332160
Note:
LED drivers are designed and intended to operate LED loads only.
Non-LED loading may be outside the specified design limits of our
LED drivers, and therefore cannot be covered by any warranty.
If you desire to use our LED drivers to operate non-LED loads
please contact us to discuss compatibility.
Specifications subject to change without notice.
Rev 9-1-15
Thomas Research Products • 1225 Bowes Rd • Elgin, IL 60123 • T 847-515-3057 • F 847-515-3047 • www.trpssl.com
TRC-150 Series
SSL Solutions Faster Than The Speed Of Light®
Pg 2 of 3
INPUT
Black (L)
White (N)
Green (GND)
OUTPUT
Red (V+)
Blue (V-)
Tc
WIRE SPECS:
AC Input: #18AWG
DC Output: #18AWG
Safety and EMC Compliance
UL8750, Compliance to UL1012, UL935,
CAN/CSA-C22.2 No. 0, CSA-C22.2 No. 107.1-01, CSA-C22.2 No. 250.0
UL/CUL
C E
EN 61347-1, EN61347-2-13
EN 55015
Conducted emission Test & Radiated emission Test
Harmonic current emissions
EN 61000-3-2
EN 61000-3-3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
Voltage fluctuations & flicker
Electrostatic Discharge (ESD): 8 kV air discharge, 4 kV contact discharge
Radio-Frequency Electromagnetic Field Susceptibility Test-RS
Electrical Fast Transient / Burst-EFT
Surge Immunity Test: AC Power Line: line to line 4 kV, line to earth 6 kV
Conducted Radio Frequency Disturbances Test-CS
Power Frequency Magnetic Field Test
EN 61000-4-11 Voltage Dips
EN 61547 Electromagnetic Immunity Requirements Applies to Lighting Equipment
Thomas Research Products • 1225 Bowes Rd • Elgin, IL 60123 • T 847-515-3057 • F 847-515-3047 • www.trpssl.com
TRC-150 Series
SSL Solutions Faster Than The Speed Of Light®
Pg 3 of 3
Efficiency / Load
Power Factor / Output Voltage
THD / Output Voltage
95%
1.00
0.95
0.90
0.85
0.80
0.75
0.70
0.65
0.60
20%
16%
12%
8%
90%
85%
80%
120Vac
220Vac
277Vac
120Vac
220Vac
277Vac
75%
120Vac
220Vac
277Vac
4%
70%
60%
0%
70%
80%
90%
100%
60%
70%
80%
90%
100%
60%
70%
80%
90%
100%
Normalized Output Voltage
Normalized Output Voltage
Normalized Output Voltage
Lifetime / Case Temperature (350mA)
Lifetime / Case Temperature (1400mA)
Lifetime / Case Temperature (5950mA)
300
250
200
150
100
50
300
250
200
150
100
50
300
250
200
150
100
50
0
30
0
40
0
30
40
50
60
80
90
Case Temperatur7e0(°C)
60
70
80
90
40
50
60
80
90
50 Case Temperature (°C)
Case Temperatur7e0(°C)
Derating Curve
Derating Curve
100
80
60
40
20
0
100
80
60
40
20
0
100Vac
100Vac (350mA, 450mA)
277Vac
-35
-20
-5
10
25
40
55
70
90
120
150
180
210
240
270
300
330
Ambient Temperature (°C)
Input Voltage (V)
Thomas Research Products • 1225 Bowes Rd • Elgin, IL 60123 • T 847-515-3057 • F 847-515-3047 • www.trpssl.com