EDS5-87 [FUJI]
OPTICAL PRESSURE TRANSMITTER; 光压力变送器型号: | EDS5-87 |
厂家: | FUJI ELECTRIC |
描述: | OPTICAL PRESSURE TRANSMITTER |
文件: | 总8页 (文件大小:130K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
FFI SYSTEM
OPTICAL PRESSURE TRANSMITTER
DATA SHEET
FBL···3
The Model FBL 3 Optical Pressure Transmitter measures
pressures of various fluids accurately, converts them into
optical digital signals and outputs them. This is an intelli-
gent transmitter providing excellent performance and func-
tions due to incorporation of electrostatic capacitance type
silicon sensor and microprocessor.
A fiber optical cable used for the signal transmission line
forms an optical field instrumentation system together with
an optical star coupler and a master station.
FEATURES
1. Resistive to noise and lightning
Optical signal ensures a reliable signal transmission, be-
cause it is not affected by external noise and inductive
lightning. Use of a nonmetallic optical (fiber) cable pre-
vents propagation of inductive lightning through the cable,
so a signal transmission immune to lightning can be re-
alized.
2. Reliability due to redundant configuration
Host system can be duplicated by using two optical cable
trunk lines (between an optical star coupler and host
system. This enhances reliability of users’ systems.
3. Intrinsic safety type explosion-proof
SPECIFICATIONS
Functional specifications
Each equipment with a built-in battery can be constructed
so as to be an intrinsic safety type individually (intrinsic
safety type barrier unnecessary).
Fluids measured:
Measuring range, operating pressure and maximum
allowable over-pressure:
Liquid, gas or steam
Range limits
[kPa]
Max.
allowable
over-
pressure
[MPa]
Span [kPa]
Operating
pressure
[MPa]
Type
Mini-
Maxi-
mum
value
Lower
Upper
range
limit
mum
value
range
limit
FBL 01
FBL 02
FBL 03
FBL 04
FBL 05
-
-
-
-
-
0.1 to 0.13 3.25
130
500
130
500
1
1.5
9
0.1 to 0.5
0.1 to 3
12.5
75
3000
10000
3000
10000
50000
0.1 to 10
0.1 to 50
250
15
75
1250 50000
EDS5-87
Date May 20, 2004
FBL···3
Process temperature, Allowable pressure limit:
Performance specifications
For details, refer to Fig. 1.
±0.1% when measuring span is 1/10 or more
of maximum span
Accuracy rating(Note)
Process
Allowable
Fill-fluid
Code
Y, G, N
W, A, D
R
temperature
pressure limit
±(0.05 + 0.005 x maximum span/measuring
span)% when measuring span is less than
2.7kPa abs
Silicon oil
Fluorolube oil
Silicon oil
-
-
-
40 to +100˚C
20 to +80˚C
15 to +100˚C
1
/
10 of maximum span
Atmospheric
pressure
Note: Percent value with respect to measuring span (including
linearity, hysteresis and repeatability in standard 23°C status)
2.7kPa abs
Ambient temperature effect:
Zero shift: ±(0.1 + 0.05 × URL/x )%/ 28°C
Overall shift: ±(0.15 + 0.05 × URL/x )%/
28°C
Self-diagnosis: Displayed on indication unit (option) and
transmitted to master station.
Item
Host system Indication unit
Where; URL: Maximum span
Measuring range abnormal
Detecting unit failure
Amplifier abnormal
Battery voltage
x :
Measuring span
3 times as large as above when the 7th
digit (material) is other than V.
Maximum allowable pressure effect:
Battery voltage low alarm
Zero shift at maximum span
±0.2% to maximum allowable pressure
Inclination effect:
Remote control function:
See Table 1.
0.1 kPa/10° or, when 13th digit code (pro-
cessing, fill fluid) is W, D or A, double the
above, at maximum span
Output signal: Optical digital signal
Power supply: Built-in lithium battery (expected life about
4 years)
Measurement period:
0.2 sec
Response time: Time constant 0.2 sec (at 23°C)
Optical cable:
Code set type, silica fiber ... core/clad di-
ameter 100/140 µm
Optical connector:
FC connector
Transmission distance:
1.5 km max. (when transmission loss of
Dead time; About 0.2 sec
Physical specifications
optical cable is 4 dB/km)
Material:
Damping:
Variable from 0.2 to 32 sec (time constant)
Detecting unit
Material
code
Zero elevation and suppression:
Possible within a range from
to maximum span.
Explosion-proof: Intrinsic safety type, JIS ib IIC T3
Ambient temperature:
Process cover
Seal diaphragm Other wetted parts
-
0.1 MPa
V
J
H
M
T
SCS14
SCS14
SCS14
SCS14
SCS14�
SUS316L�
SUS316�
SUS316L · Gold-plated�SUS316�
Hastelloy-C�
Monel�
Hastelloy-C�
Monel�
–30 to +70°C
–10 to +60°C for intrinsic safety explo-
sion-proof type
–20 to +70°C when provided with indica-
tor
Except for
FBL 05
Tantalum�
Tantalum�
Hastelloy-C�
Monel�
B
L
U
Hastelloy-C lining Hastelloy-C�
Monel lining� Monel�
Tantalum lining Tantalum
Tantalum
Environmental protection:
–10 to +60°C when filled with fluorolube
oil
Meets JIS C0920, immersion-proof
(equivalent to IEC IP67 or NEMA 6/6P)
Process connection:
Storage temperature:
–40 to +80°C
Rc1/4 or 1/4-18NPT (whichever selected
by code symbol)
Oval flange threads 7/16-20UNF
Optical cable connection:
G1/2 or 1/2 -14NPT (whichever selected
by code symbol)
Mounting method:
Mounted on the 50A (2B) pipe with U-
bolt
Finish:
Epoxy-polyurethane double coat,
Color: silver (blue for amplifier case cover)
External dimensions:
See OUTLINE DIAGRAM.
4.5 to 5 kg
Orientation of transmission unit:
Indicator unit turnable 90° upward/down-
ward relative to detection unit.
Mass:
2
Optional specifications
Indication unit: 5-digit LCD indication, % or real scale in-
dication (as specified by code symbol)
Operating temperature range: –20 to
+70°C
Oxygen oil-proof processing:
Fluorolube filled.
Wetted parts degreased
and cleaned.
Chlorine service:Fluorolube oil filled.
NACE specification:
Varies with
material.
Refer to
CODE
SYMBOLS.
H2S-proof treatment in
accordance with NACE
specification
Table 1 Remote Control Function
(Items readable and setting from hand-held
communicator)
Item
Reading Setting
Description
Maximum range
Maximum measuring range
of equipment
Measuring range
Damping
Real scale
Actual measuring range
Variable within 0.2 to 32 sec.
Indication in industrial value
indication
Battery voltage
Error indication
Battery voltage of equipment
Errors of detection unit and
amplifier
Measured value
Adjustment
Measured data
Zero and span adjustment
Note: For operation of the “3” type transmitter (“3” at the 8th digit
of product code), a hand-held communicator is required to
have a version 1.6 or higher, but a communicator before
version 1.6 can be operated with memory data updated.
(Refer to the instruction manual of transmitter.)
Fill-fluid: Silicon oil (Code: Y,G,N)
Fill-fluid: Silicon oil (Code: R)
[kPa abs]
101
Operating area
20
4
2.7
Non-operating area
–40 –15
60 85 100 [°C]
Process temperature
Fig. 1 Relation between process temperature and
operating pressure
3
FBL···3
SYSTEM BLOCK DIAGRAM
1:1 system
Host system
1 to 5V DC
4 to 20mA DC
Master station
Optical fiber type
electric converter
(Type; PSN)
Control room
Field
Star coupler
Transmitter
Transmitter
Field equipment
(max. 8 units)
Transmission distance: 1.5 km max.
(between master station and field equipment)
Transmission distance: 4 km max.
4
CODE SYMBOLS
1
2
3
4
5
6
7
8
9 10111213 1415
F B L
0
3
F
Description
Process cover (4th digit)
Process connection Cable lead-in port
Rc1/4
G1/2
S
T
1/4-18NPT
1/2-14NPT
Measuring span (6th digit)
3.25....... 130kPa
12.5...... 500kPa
75........ 3000kPa
250.....10000kPa
1
2
3
4
5
1250.. 50000kPa
Material (7th digit)
Process cover
SCS14
SCS14
Seal diaphragm
SUS316L
SUS316L · Gold-plated SUS316
Other wetted parts
SUS316
V
J
SCS14
SCS14
SCS14
Hastelloy-C
Monel
Tantalum
Hastelloy-C
Monel
Tantalum
Hastelloy-C
Monel
H
M
T
B
L
Not available
when 6th
digit is “5”.
Hastelloy-C lining Hastelloy-C
Monel lining
Monel
Tantalum lining
Tantalum
Tantalum
U
Indicator (9th digit)
Not provided
Digital, % indication
Digital, real scale indication
A
L
P
Explosion-proof (10th digit)
Non-explosion proof
Intrinsic safety, JIS
A
G
Side vent/drain and fixture (11th digit)
Side vent/drain
Fixture
None
Yes (stainless steel)
None
Yes (stainless steel)
A
C
D
F
None
None
Yes
Cannot be specified
when 7th digit is “B”,
“L” or “U”.
Yes
Treatment and Fill-fluid (13th digit)
Treatment
None
None
Degreasing
Oxygen oil-proof
processing
Chlorine service
Fill-fluid
Y
W
G
Silicon oil
Fluorolube oil
Silicon oil
A
Fluorolube oil (when 7th digit is “V”)
D
N
R
Fluorolube oil (unavailable when 7th digit is “V”,
“M” or “L”)
NACE specification Silicon oil (unavailable when 6th digit is “5”, or 7th
digit is “T” or “U”)
None
Silicon oil (for vacuum)
O-ring material (for process cover)(14th digit)
Viton
Teflon
A
B
Bolt/nut (15th digit)
NACE bolt/nut (ASTM A193 B7M/A194 2HM)
NACE bolt/nut (ASTM A320 L7M/A194 2HM)
SUS304/SUS304.... (For general use)
SUS630/SUS304.... Specify when 6th digit is “5”.
C
D
E
F
Cannot be specified
when 6th digit is “5”.
5
FBL···3
OUTLINE DIAGRAM (Unit:mm)
P
V
J
H
M
T
241
Mounting pipe
JIS 50A (2B)
80
S
T
A
C
FBL
0
3–
108
70
U-bolt
(M8)
315
54
15
Indicator (option)
B
Gas vent, drain port
37 27
47
Optical cable lead-in port
A
B
L
U
S
T
A
C
Pressure connection
FBL
0
3–
4–7/16-20UNF
Thread depth 13
(for oval flange)
318
41.3
27
View from arrow P
φ7
φ15
54
A
Pressure connection
40 27
D
E
47
2–7/16–20UNF
Thread depth 10
(for oval flange)
φ18.5
Details of “B” Details of “A”
φ16
+0.2
+0.1
φ12
Type
FBLS
FBLT
D
E
Rc1/4
G1/2
1/4–18NPT
1/2–14NPT
φ4
Details of “A”
6
SCOPE OF DELIVERY
Instrument body and pipe fixture (as specified)
ITEM TO BE PREPARED SEPARATELY
Oval flange:
To be used as a flange of connecting pipe
port.
For details, refer to the DATA SHEET of
oval flange (EDS6-10).
ORDERING INFORMATION
1. Model type
2. Measuring range
3. Indication scale for real scale specification
4. Others
7
FBL···3
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Head Office
6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan
http://www.fesys.co.jp/eng
Sales Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187
http: //www.fic-net.jp/eng
Printed in Japan
Information in this catalog is subject to change without notice.
相关型号:
©2020 ICPDF网 联系我们和版权申明