L6622-01 [HAMAMATSU]

130 KV MICROFOCUS X-RAY SOURCE; 130千伏微焦点X射线源
L6622-01
型号: L6622-01
厂家: HAMAMATSU CORPORATION    HAMAMATSU CORPORATION
描述:

130 KV MICROFOCUS X-RAY SOURCE
130千伏微焦点X射线源

文件: 总4页 (文件大小:619K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
130 kV  
LM6IC6R2OF2O-C0U1S X-RAY SOURCE  
NEW  
FEATURES  
APPLICATIONS  
X-ray Non-destructive Test  
Focal Spot Size: 10 µm  
Providing 10 µm focal spot size, for the sealed-off type  
X-ray source with built-in power supply. It gives a clear  
clairvoyance image despite higher magnification ratio.  
• Printed Circuits  
• Electronic Components  
• Semiconductor Devices  
• Soldered Parts  
• Combinated Materials  
• New Materials  
• Ceramics  
• Rubbers  
• Plastics  
Easy Handling  
• Die casting  
Convenient handling (with no high voltage wiring) since the  
air cooled X-ray source and the high voltage power supply  
are in one package.  
Multilayer Printed Circuit Board  
X-ray Inspection•Drilling Instrument  
Industrial On-line Process Control  
and Measurement  
Continuous Operation  
It allows continuous maximum output, 130 kV and 300 µA,  
operation (Large focal spot operation).  
Built-in External Control Function  
It is automatically operable from external control since it has  
a built-in RS-232C interface.  
Industrial X-ray Computer  
Tomography System  
SPECIFICATIONS  
GENERAL  
Parameter  
Value/Description  
Unit  
Target Voltage  
20 to 130  
kV  
µA  
µA  
40 to 100 kV  
100 to 130 kV  
0 to 250b  
Small Focal Spot  
Target Currenta  
0 to 100  
Large Focal Spot  
0 to 300  
µA  
Small Focal Spot  
Large Focal Spot  
13  
39  
W
W
Maximum Output Power  
Small Focal Spot  
Large Focal Spot  
10  
40  
µm  
µm  
Focal Spot Size  
Beam Angle  
43  
degree  
Minimum Distance Focus / Object  
Environmental X-ray Dose Leakage  
Operation  
18  
3
mm  
mSv/h Max.  
Continuous  
NOTE: a Refer to Figure 1  
b
In the range of output (= Tube voltage × Tube current) less than 10 W  
X-RAY TUBE UNIT  
X-RAY CONTROL UNIT  
Parameter  
X-ray Tube  
Description  
Sealed Type  
Parameter  
Description  
Target Voltage/Current  
Pre-set, Auto Warm-up  
Safety Interlock  
Function  
Cooling Method  
Window Material  
Target Material  
Cathode Material  
Window Position  
High Voltage  
Power Supply  
Operation / Storage  
Temperature  
Forced Air Cooling  
Beryllium (200 µmt)  
Tungsten  
Dispenser Cathode  
End-window  
Protection  
External Control  
Operation / Storage  
Temperature  
Operation / Storage  
Humidity  
RS-232C  
0 to +40 °C  
Built-in Type  
85 % RH Max.a  
Power Consumption  
Inter Voltage  
200 W Max.  
24 V dc  
+10 to +40 °C / 0 to +50 °C  
Operation / Storage  
Humidity  
Weight  
Designed for both bench-top  
and rack mounting  
Approx. 6 kg  
85 % RH Max.a  
Approx. 12.5 kg  
Installation Method  
Weight  
NOTE: a Without moisture condensation.  
Figure 1: X-ray Tube Operational Range  
TLSOB0046EB  
350  
300  
LARGE FOCAL SPOT  
250  
200  
150  
100  
SMALL FOCAL SPOT  
50  
0
0
20  
40  
60  
80  
100  
120  
140  
TARGET VOLTAGE (kV)  
130 KV MICROFOCUS X-RAY SOURCE  
DIMENSIONAL OUTLINE (Unit: mm)  
X-RAY TUBE UNIT  
X-RAY UNIT INSTALLATION SCREW HOLE  
4-M6 D8  
55  
1
20  
1
X-RAY WINDOW  
18  
AIR VENT  
BEAM ANGLE  
FOCAL SPOT  
CONTROL CABLE RECEPTACLE  
90.0 0.5  
110  
11  
1
2
100 MIN.  
300  
2
X-RAY UNIT INSTALLATION SCREW HOLES  
4-M6 D8  
15  
175.0 0.5  
TLSOA0046EB  
X-RAY CONTROL UNIT  
100 MIN.  
FRONT VIEW  
SIDE VIEW  
X-RAY 130 CONTROL UNIT  
VOLTAGE  
CURRENT  
OVER  
ERROR  
X-RAY MODE  
OFF  
X-RAY  
kV  
µA  
STANDBY  
AGING  
CONTROL  
CONTROL  
SPOT SIZE  
LARGE  
OPERATE  
ON  
PRE-SET  
PRE-SET  
ON  
OFF  
REMOTE  
INTER LOCK  
9
426  
482  
2
2
9
40  
300  
2
30  
INTERCONNECTION CABLE CONNECTOR  
DIA 33 mm MAX.  
REAR VIEW  
T
6.3A 250V  
X-RAY REMOTE  
OUTPUT  
AGING SIGNAL  
INTER LOCK1  
INTER LOCK2  
24V  
RS-232  
IDENTIFICATION PLATE  
LABEL  
TLSOA0047ED  
130 KV MICROFOCUS X-RAY SOURCE  
RELATED PRODUCTS  
X-RAY IMAGE INTENSIFIER CAMERA UNIT  
C7716, C7716-10  
The C7716 series X-ray image intensifier (I. I.) camera unit now offers greatly  
improved X-ray detection efficiency even at low energy levels. This improve-  
ment stems primarily from a built-in X-ray image intensifier having an extreme-  
ly thin aluminum input window. Its thickness is only 0.3mm or less, virtually at  
the limit of present technology providing excellent X-ray transmit-tance and  
low scattering.  
The results are sharp, clear, high-quality images taken at low energy X-ray lev-  
els down to several keV which penetrate plastic (PET) materials.  
X-RAY IMAGE INTENSIFIER CAMERA UNIT  
C7876, C7876-10  
The C7876 is an X-ray image intensifier camera unit ideal for non-destructive  
inspection of light-element materials and radiation imaging at low-energy  
X-ray levels.  
The C7876 remarkably improves X-ray transmittance at low-energy X-ray lev-  
els by using a beryllium window instead of the aluminum window currently  
used for most X-ray image intensifiers.  
The result is a sharp and clear, high-contrast image taken in real time even at  
low energy X-ray levels down to a few keV.  
!
PRE-CAUTION TO USE  
1. X-ray emitted from this device is harmful for human body. And it should be necessary for the operator to protect himself/herself  
from it.  
2. During an operation, the X-ray tube unit should be installed in the X-ray shielded cabinet in order to avoid any X-ray leakage.  
Also the safety interlock system in X-ray control unit should be always used in order to avoid any misoperation.  
# WARRANTY PERIOD  
This device is guaranteed for one and a half years from data of purchase or 5000 hours of operation, whichever comes first.  
The warranty extends only to replacement of the products. The warranty does not cover damage due to misuse or natural calamity.  
*
This product(s) conforms to the EMC directive (89/336/EEC) of the European Union.  
* To meet FDA standards, the Interlock-1 circuit incorporates a relay that shuts off the X-ray generation power supply circuit if the circuit is open.  
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office.  
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are  
subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2001 Hamamatsu Photonics K.K  
HOMEPAGE URL http://www.hamamatsu.com  
HAMAMATSU PHOTONICS K.K., Electron Tube Center  
314-5, Shimokanzo, Toyooka-village, Iwata-gun, Shizuoka-ken, 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205  
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P. O. Box 6910, Bridgewater. N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: usa@hamamatsu.com  
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: info@hamamatsu.de  
France: Hamamatsu Photonics France S.A.R.L.: 8, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: infos@hamamatsu.fr  
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road Welwyn Garden City Hertfordshire AL7 1BW, United Kingdom, Telephone: 44-(0)1707-294888, Fax: 44(0)1707-325777 E-mail: info@hamamatsu.co.uk  
North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171-41 SOLNA, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: info@hamamatsu.se  
TLSO1024E04  
Italy: Hamamatsu Photonics Italia: S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741 E-mail: info@hamamatsu.it  
JAN. 2002 IP  
Printed in Japan (500)  

相关型号:

L6660

MILLI-ACTUATOR DRIVER
STMICROELECTR

L6668

SMART PRIMARY CONTROLLER
STMICROELECTR

L6668TR

SMART PRIMARY CONTROLLER
STMICROELECTR

L6668_06

SMART PRIMARY CONTROLLER
STMICROELECTR

L6690

INFRARED PULSED LASER DIODE
HAMAMATSU

L6690-53_15

PULSED LASER DIODE
HAMAMATSU

L6699D

Enhanced high voltage resonant controller
STMICROELECTR

L6699DTR

Enhanced high voltage resonant controller
STMICROELECTR

L6701

3 Phase Controller for VR10, VR9 and K8 CPUs
STMICROELECTR

L6701TR

3 Phase Controller for VR10, VR9 and K8 CPUs
STMICROELECTR

L6706TR

VR11.1 single phase controller with integrated driver
STMICROELECTR

L6710

6 BIT PROGRAMMABLE DUAL-PHASE CONTROLLER WITH DYNAMIC VID MANAGEMENT
STMICROELECTR