GENERALDESCRIPTION  
REMOTE TERMINALFEATURES  
The HI-6120 and HI-6121 provide a complete, integrated,  
3.3V MIL-STD-1553 Remote Terminal in a monolithic  
silicon gate CMOS device. Two host interface options are  
offered: The HI-6120 uses a 16-bit parallel host bus  
interface for access to registers and RAM and is offered in  
a 100-pin plastic quad flat pack (PQFP). The HI-6121 has a  
4-wire SPI (Serial Peripheral Interface) host connection  
and comes in a reduced pin count 52-pin PQFP or 64-pin  
QFN. Both devices handle all aspects of the MIL-STD-  
1553 protocol, including message encoding, decoding,  
error detection, illegal command detection and data  
buffering. Host data management is simplified by storing  
message information and data within the on-chip 32K x 16  
static RAM.  
Fully integrated 3.3V Remote Terminal meets all  
requirements for MIL-STD-1553B Notice 2  
·
Four data buffer methods for subaddress transmit and  
·
receive commands: indexed (single) buffering, ping-  
pong (double) buffering and two circular buffer modes  
Independently selectable data buffer modes for  
transmit and receive commands on each subaddress  
·
Simplified mode code command handling  
·
·
Integral 16-bit Time-Tag counter has programmable  
options for clock, interrupts and auto-synchronization  
Message information and time-tag words are stored  
with message data words for all transacted messages  
·
·
A descriptor table in shared RAM provides fully  
programmable memory management. Multiple descriptor  
tables can be implemented for fast context switching.  
Transmit and receive commands can use any of four  
different data buffer modes: indexed (single) buffering,  
ping-pong (double) buffering or two circular buffer  
schemes. Transmit and receive commands for each  
subaddress may use different buffer modes. Mode code  
commands employ a simple scheme for storing mode data  
and message information with programmable interrupts.  
In compliance with MIL-STD-1553B Notice 2, received  
data from broadcast messages may be optionally  
separated from non-broadcast received data  
Optional interrupt log buffer stores the most recent 16  
interrupts to minimize host service duties  
·
Optional illegal command detection uses internal table  
Optional automatic self-initialization at reset  
+/- 8kV ESD Protection (HBM, all pins)  
MIL-STD-1760 compliant  
·
·
·
·
The device provides internal illegalization capability,  
allowing any subset of subaddress, command T/R bit,  
broadcast vs non-broadcast and word count (or mode  
code) to be illegalized, resulting in a total of 4,096 possible  
combinations. The illegalization table resides in internal  
RAM. The RT can also operate without illegal command  
detection, providing “in form” responses to all valid  
commands. Broadcast command recognition is optional.  
PIN CONFIGURATION (Top View)  
HI-6121 in 52-PQFP Package  
The HI-6120 and HI-6121 provide programmable  
interrupts for automatic message handling, message  
status and general status. A host interrupt history log  
maintains information about the last 16 interrupts.  
COMP -  
CE -  
MODE -  
SI -  
SCK -  
SO -  
MCLK -  
RTA0 -  
RTA1 -  
RTA2 - 10  
MR - 11  
RTA3 - 12  
RTA4 - 13  
1
2
3
4
5
6
7
8
9
39 - TEST  
38 - LOCK  
37 - MTSTOFF  
36 - BUSA  
35 - VCCP  
34 - BUSA  
33 - BUSB  
32 - VCCP  
31 - BUSB  
30 - TEST0  
29 - TEST1  
28 - TEST2  
27 - TEST3  
HI-6121PQx  
The HI-6120 and HI-6121 can be configured for automatic  
self-initialization. A dedicated SPI port reads data from  
external serial EEPROM memory to fully configure the  
descriptor table, illegalization table and host interrupts.  
Internal dual-redundant transceivers provide direct  
connection to bus isolation transformers. The device is  
offered with industrial temperature range. Extended  
temperature range is also offered, with optional burn-in. A  
“RoHS compliant” lead-free option is offered.  
HOLT INTEGRATED CIRCUITS  
www.holtic.com  
HI-6120 Rev New  
11/09  
HI-6120, HI-6121  
BLOCK DIAGRAM  
HI-6120 MIL-STD-1553 Terminal With Host Bus Interface  
HI-6121 MIL-STD-1553 Terminal With Host SPI Interface  
LOCK  
EE1K  
VCC  
GND  
SHARED  
STATIC RAM  
AND  
REGISTERS  
LOGIC POWER  
AUTOEN  
EECOPY  
MTSTOFF  
CONFIG.  
OPTION  
LOGIC  
RTA4 - 0  
RTAP  
32K X 16  
ADDRESS  
SPACE  
TRANSCEIVER  
POWER  
VCCP  
MCLK  
BENDI  
BWID  
HI-6120  
ONLY  
BTYPE  
WPOL  
INTERNAL  
CLOCKS  
TTCLK  
(OPT)  
R / W or WE  
STR or OE  
A0 / LB  
CONTROL  
ADDRESS  
DATA  
HOST BUS  
INTERFACE  
MEMORY  
ACCESS  
MANAGER  
HI-6120  
ONLY  
WAIT or WAIT  
A15:1  
TEST7:0  
TEST  
TEST  
LOGIC  
D15:0  
MODE  
COMP  
CE  
HOST SPI  
INTERFACE  
SCK  
SI  
HI-6121  
ONLY  
TXINHA  
SO  
BUSA  
BUS  
ACKHW  
*
}
ACKMES  
BUSA  
BUSB  
MESSAGE  
REMOTE  
TERMINAL  
STATE  
SEQUENCER  
AND DUAL  
ENCODER-  
DECODERS  
TXINHB  
BUS  
SSYSF  
MR  
MACHINE  
INTHW  
INTMES  
READY  
ACTIVE  
DISCRETE  
SIGNAL  
INTERFACE  
TO HOST  
BUSB  
BUS  
TRANSCEIVERS  
Combined into ACKINT pin  
on HI-6121PQx varient  
*
SPI MASTER MODE  
INTERFACE  
TO OPTIONAL  
SERIAL EEPROM  
(AUTO-CONFIG)  
HOLT INTEGRATED CIRCUITS  
2
HI-6120, HI-6121  
PIN DESCRIPTION  
THESE PINS APPLY TO BOTH HI-6120 AND HI-6121  
PIN  
TYPE  
DESCRIPTION  
INTHW  
OUTPUT  
Hardware Interrupt output, active low.This signal is programmed as a brief low-going  
pulse output or as a level output by the INTSEL bit in Configuration Register 1.  
INTMES  
MR  
OUTPUT  
INPUT  
Message Interrupt output, active low. This signal is programmed as a brief low-going  
pulse output or as a level output by the INTSEL bit in Configuration Register 1.  
Master Reset, active low. Internal 50KW pull-up resistor. The host can also assert  
software reset by asserting the SRST bit in Configuration Register 1.  
MTSTOFF  
INPUT  
Memory test disable, active high. Internal 50KW pull-down resistor. When this pin is low,  
the device performs a memory test on the entire RAM after rising edge on the MR reset  
pin. When this pin is high, the RAM test is skipped, resulting in a faster reset process.  
For further information, refer to the data sheet section entitled “Reset and Initialization.”  
EECOPY  
AUTOEN  
INPUT  
INPUT  
EEPROM Copy, active high. Internal 50KW pull-down resistor. This input is used to start  
the process that copies registers and configuration tables to serial EEPROM. Refer to  
the data sheet section entitled “Reset and Initialization.”  
Auto-Initialize Enable, active high. Internal 50KW pull-down resistor. If pin is high at  
rising edge on MR reset input, automatic initialization proceeds, copying configuration  
data to registers and RAM from an external serial EEPROM via the dedicated auto-  
initialization SPl port. Refer to the data sheet section entitled “Reset and Initialization.”  
EE1K  
INPUT  
INPUTS  
INPUT  
When the AUTOEN pin is high, the EE1K input sets the range of the auto-initialization  
process. When EE1K is low, registers and RAM occupying the 32K address range from  
0x0 to 0x7FFF are initialized. For applications needing faster initialization, when EE1K is  
high, only registers and RAM occupying the 1K address range from 0x0 to 0x03FF are  
initialized. This pin has an internal 50KW pull-down resistor. If the AUTOEN pin is low,  
this pin is not used. Refer to the data sheet section entitled “Reset and Initialization.”  
RTA4:0  
RTAP  
Remote terminal address bits 4 - 0, and parity bit. Internal 50KW pull-up resistors. The  
RTAP pin should provide odd parity for the address present on pins RTA4:0. Terminal  
address and parity pin levels are latched into the Operational Status register when rising  
edge occurs on the MR pin. The Operational Status Register value (not these pins)  
reflects the active terminal address. The register value can be overwritten by the host  
under some circumstances. See Operational Status Register description.  
LOCK  
Internal 50KW pull-down resistor. Pin state is latched into the Operational Status register  
LOCK bit when rising edge occurs on the MR pin. If Operational Status register LOCK  
bit is high, terminal address in the register cannot be overwritten by a host register write.  
If Operational Status register LOCK bit is low, the host can overwrite the five terminal  
address bits and address parity bit in the Operational Status register.  
TXINHA  
TXINHB  
INPUTS  
Transmit Inhibits for Bus A and Bus B, active high. Internal 50KW pull-down resistors.  
These inputs are logically ORed with the corresponding TXINHA and TXINHB bits in  
Configuration Register 1. If the input pin or register bit is high, bus transmit is disabled.  
READY  
OUTPUT  
Pin is low when auto-initialization or built-in test is in-process. Host should not access  
shared RAM or device registers when pin state is low. When output is high, the shared  
RAM and registers may be configured, and device will begin terminal execution when  
the STEX (start execution) bit in Configuration Register 1 is set.  
ACTIVE  
MCLK  
OUTPUT  
INPUT  
Pin is high when the HI-6120 is actively processing a 1553 command, otherwise low.  
Master clock input, 50.0 MHZ 0.01ꢀ (100ppm). Internal 50KW pull-down resistor.  
TTCLK  
INPUT  
Time-Tag Clock input. Internal 50KW pull-down resistor. When Configuration Register 1  
bits TTCK2:0 = 001, this pin is the clock input for the Time Tag counter. For other values  
of TTCK2:0, the Time-Tag counter is internally clocked so the TTCLK pin is not used.  
SSYSF  
ECS  
INPUT  
Subsystem fail input, active high. Internal 50KW pull-down resistor. When this input is  
high, the HI-6120 terminal sets the SUBSYS flag in its status word.  
OUTPUT  
Chip select output for the dedicated Serial Peripheral Interface (SPI) that connects to  
the optional external serial EEPROM used for automatic self-initialization. For this auto-  
initialization SPI, the device operates in SPI master mode while the external memory  
operates in slave mode. This SPI is separate from the host SPI found in the HI-6121.  
HOLT INTEGRATED CIRCUITS  
3
HI-6120, HI-6121  
PIN DESCRIPTION, Cont.  
THESE PINS APPLY TO BOTH HI-6120 AND HI-6121  
PIN  
TYPE  
DESCRIPTION  
ESCK  
OUTPUT  
Serial Clock output signal for the dedicated auto-initialization SPI connected to external  
auto-initialization EEPROM.  
MISO  
MOSI  
INPUT  
Serial Input signal (Master-In Slave-Out) for the dedicated auto-initialization SPI  
connected to external auto-initialization EEPROM. Internal 50KW pull-down resistor.  
OUTPUT  
Serial Output signal (Master-Out Slave-In) for the dedicated auto-initialization SPI  
connected to external auto-initialization EEPROM.  
BUSA, BUSA ANALOG  
BUSB, BUSB ANALOG  
Bi-directional analog interface to MIL-STD-1553 bus A isolation transformer, positive and  
negative signals respectively.  
Bi-directional analog interface to MIL-STD-1553 bus B isolation transformer, positive and  
negative signals respectively.  
VCC, VCCP  
GND  
POWER  
POWER  
INPUT  
3.3V supply voltage inputs for logic and transceiver circuits  
Ground pin for logic and transceiver circuits  
TEST  
Test enable. Internal 50KW pull-down resistor. The host asserts this pin to perform RAM  
self-test or loopback tests.  
TEST7:0  
BI-DIR  
Test pins used for factory testing. Internal 50KW pull-down resistor. Do not connect  
these pins.  
MODE  
COMP  
INPUT  
INPUT  
Test pin used for factory testing. Internal 50KW pull-up resistor. Do not connect this pin.  
Test pin used for factory testing. Internal 50KW pull-down resistor. Do not connect this  
pin.  
CE  
INPUT  
INPUT  
Chip Enable, active low. Internal 50KW pull-up resistor. When asserted, this pin enables  
host read or write accesses to device RAM or registers. On HI-6121, it is normally  
connected to a host SPI chip select output signal.  
BENDI  
Configuration pin for selecting “endianness” of the host bus interface when byte transfers  
are used. Internal 50KW pull-up resistor. Endianness is the system attribute that  
indicates whether integers are represented with the most significant byte stored at the  
lowest address (big endian) or at the highest address (little endian). Internal storage is  
“big endian.” When using the HI-6120, this pin only applies when the host bus is  
configured for 8-bit width, that is, when BWID equals 0. When the HI-6120 is configured  
for 16-bit bus width, the BENDI input pin is “don’t care.” When using the HI-6121, this  
pin controls the byte order of the 16-bit data following the SPI command.  
When BENDI is low, “little endian” is chosen; the low order byte (bits 7:0) is transacted  
before the high order byte (bits 15:8). When BENDI is high, “big endian” is chosen and  
the high order byte is transacted on the host bus before the low order byte.  
ACKHW*  
INPUT  
INPUT  
Hardware Interrupt Acknowledge, active high. Internal 50KW pull-down resistor. This  
input is only used when the INTSEL bit in Configuration Register 1 is asserted to enable  
level interrupts. After interrupt assertion causes the INTHW output to go low, a high  
state (60ns minimum duration) on ACKHW will clear the INTHW output to logic 1. The  
interrupt is also cleared by reading the Pending Interrupt Register.  
ACKMES*  
Message Interrupt Acknowledge, active high. Internal 50KW pull-down resistor. This input  
is only used when the INTSEL bit in Configuration Register 1 is asserted to enable level  
interrupts. After interrupt assertion causes the INTMES output to go low, a high state  
(60ns minimum duration) on ACKMES will clear the INTMES output to logic 1. The  
interrupt is also cleared by reading the Pending Interrupt Register.  
* Note: These pins are combined into the ACKINT pin on HI-6121PQx variant.  
HOLT INTEGRATED CIRCUITS  
4
HI-6120, HI-6121  
PIN DESCRIPTION, Cont.  
THESE PINS APPLY TO HI-6120 ONLY  
PIN  
TYPE  
DESCRIPTION  
D15:0  
I/O  
Tristate data bus for host read/write operations upon registers and shared RAM.  
Internal 50KW pull-down resistors. All read/write operations transact 16 bit words, but  
bus width can be configured for 8 or 16 bits. For 8 bit bus width, pins D15:8 are not  
connected; each 16-bit word is transacted as a pair of upper and lower byte operations,  
with data presented sequentially on pins D7:0. For compatibility with different host  
processors, when byte transfers are enabled the BENDI input pin sets whether the low  
order byte is transferred before the high order byte, or vice versa.  
A15:1 and  
A0 (LB)  
INPUTS  
Address bus for host read/write operations upon registers and shared RAM. For 16-bit  
bus width, address bit A0 (LB) from the host is not used. For 8-bit bus width, bit A0  
equals 0 during the first byte read/write access; while A0 equals 1 during the second  
byte access.  
BWID  
INPUT  
INPUT  
Configuration pin for host bus width. Internal 50KW pull-up resistor. High selects 16-bit  
bus width, low selects 8-bit bus width.  
BTYPE  
Configuration pin for host bus read/write control signal style. Internal 50KW pull-up  
resistor. High selects “Intel style” using separate read strobe OE (output enable) and  
write strobe WE. Low selects “Motorola style” using single read/write strobe STR and  
read/write select signal, R/W.  
R/W or WE  
STR or OE  
INPUT  
INPUT  
R/W (read/write) signal when BTYPE pin is low, or WE (write enable) when BTYPE pin  
is high. Internal 50KW pull-up resistor. Used for host read or write accesses to device  
RAM or registers. Important: This pin or the CE pin should be high during all address  
transitions.  
Common STR (read/write strobe) when BTYPE pin is low, or OE (output enable) when  
BTYPE pin is high. Internal 50KW pull-up resistor. Used for host read or write accesses  
to device RAM or registers.  
WAIT or WAIT OUTPUT  
Host bus read cycle “wait” output. For compatibility with different host processors, this  
output can be made active high or active low, set by the state of the WPOL input pin.  
The WAIT output may be ignored when the host processor’s read cycle time is  
sufficiently slow to meet worst case (slowest) read cycle timing for this device, or when  
wait cycles have been enabled from the processor. The WAIT output is useful when the  
host processor runs at high clock rates and/or when processor read wait states do not  
provide adequate timing margin for worst case (slowest) read cycle timing for this  
device.  
WPOL  
INPUT  
Configuration pin for WAIT output polarity. Internal 50KW pull-up resistor. When WPOL  
is low, the “wait” output is active low (WAIT). When WPOL is high, the “wait” output is  
active high (WAIT). A multiple word sequential read will always assert WAIT during the  
first read cycle. As long as successive reads are sequential, no further wait output  
occurs.  
THESE PINS APPLY TO HI-6121 ONLY  
PIN  
TYPE  
DESCRIPTION  
SO  
OUTPUT  
Serial Peripheral Interface (SPI) Serial Output pin. SO is normally connected to MISO  
(Master In - Slave Out) pin on host SPI port. The SO pin is tri-stated when not  
transmitting serial data to host.  
SI  
INPUT  
Serial Peripheral Interface (SPI) Serial Input pin. Internal 50KW pull-down resistor. SI is  
normally connected to MOSI  
(Master Out - Slave In) pin on host SPI port.  
SCK  
INPUT  
INPUT  
Serial Peripheral Interface (SPI) Serial Clock pin. Internal 50KW pull-down resistor.  
SCK is normally connected to SCK output pin on host SPI port  
.
ACKINT  
(HI-6121PQx  
variant only)  
Interrupt Acknowledge, active high. Internal 50KW pull-down resistor. This input is only  
used when the INTSEL bit in Configuration Register 1 is asserted to enable level  
interrupts. After interrupt assertion causes the INTHW or INTMES output to go low, a  
high state (60ns minimum duration) on ACKINT will clear the INTHW or INTMES output  
to logic 1. Interrupt are also cleared by reading the Pending Interrupt Register.  
HOLT INTEGRATED CIRCUITS  
5
HI-6120, HI-6121  
FUNCTIONALOVERVIEW  
Illegalization Table  
Optional illegal command detection utilizes an Illegalization  
Table in the shared RAM. The table can illegalize any logical  
combination of 11 command word bits for subaddress, T/R  
bit and word count (or mode code), plus broadcast vs non-  
broadcast status, resulting in a total of 4,096 possible  
combinations. The Illegalization Table Base Address  
Register is initialized with the table’s start address. Terminal  
response to an illegal command sets “message error” status  
and transmits Status Word only. If illegal command detection  
is not used (that is, no “illegal” entries in Illegalization Table),  
the terminal responds “in form” to all valid commands.  
The Holt HI-6120 or HI-6121 provides a complete Remote  
Terminal (RT) interface between a host and a MIL-STD-  
1553B dual redundant data bus. It automatically handles all  
aspects of the MIL-STD-1553 protocol, namely,  
encoding/decoding, message formatting, error checking,  
message data buffering, protocol checking, illegalization  
and default terminal responses. Internal static RAM is  
shared by the host and device logic, providing efficient  
storage for message data and information about messages,  
updated after each message transaction. The shared RAM  
also contains host-initialized tables that define terminal  
operation.  
Message Data Buffers  
After master reset, all locations in shared memory are reset  
to 0000 hex. Ordinary transmit or receive commands  
transfer 1 to 32 data words. These are called “subaddress  
commands,” distinguishing them from “mode code  
commands,” described in the next paragraph. By initializing  
the Descriptor Table, the host allocates space in shared  
RAM for storing message data words and message  
information words. Data pointers in the table assign  
separate data buffer addresses in memory for each  
command. Data storage arrangement differs by choice of  
data buffer method. Two examples are shown for each of the  
four buffer modes in Figures 11-18. After successfully  
transacting a message with one or more received data  
words, the RT writes into the assigned data buffer. While  
transacting a message with one or more transmitted data  
words, the RT reads data for transmission from the assigned  
data buffer. Before transmit commands occur, the host  
should write desired data into assigned transmit data buffers  
in shared RAM. Transmit subaddress data buffers can be  
optionally loaded by auto-initialization.  
Two options are offered for host interface. The HI-6120 uses  
a 16-bit tri-state data bus, ideally suited for memory-mapped  
host processor operation. The HI-6121 uses a 3-wire Serial  
Peripheral Interface (SPI) with powerful SPI command set.  
Registers occupy the lowest 32 addresses of the 32K  
memory address space. Internal registers (or contained bit  
fields) are partitioned as read-only or read-write so the host  
can exercise configuration and control without risk of  
misconfiguration caused by accidental writes to device-  
maintained registers or bit fields.  
Dedicated output pins convey status to the host, and  
generate host interrupts for preselected events. Before  
processing messages, internal registers and transmit data  
buffers in shared RAM must be initialized by the host to  
define the desired message responses. Optional auto-  
initialization using parameters in external EEPROM can  
replace host initialization.  
SHARED RAM UTILIZATION  
Storage for Mode Code Commands  
MIL-STD-1553 defines “mode code commands” that are  
used for command and control, instead of data transfer. The  
various “mode commands” transfer a single data word, or no  
data word at all. The user has two choices for storing mode  
command data: (1) similar to subaddress command data,  
mode command data can be stored in RAM data buffers  
assigned by the host-initialized Descriptor Table, or (2)  
When “simplified mode command processing” is chosen,  
mode command data is stored within the Descriptor Table  
itself. Just six defined mode commands transfer a data word;  
thus, option 2 is often preferred since initialization is easier.  
Descriptor Table  
The host-initialized Descriptor Table, residing in shared  
RAM, defines terminal response to valid commands. The  
table is comprised of 4-word Descriptor Blocks. Each of 32  
subaddresses and 32 mode code values has two descriptor  
blocks, one for transmit and one for receive, for a total of 128  
descriptor blocks. The first word in each descriptor block  
defines message options (interrupt selections, data buffer  
mode, etc.). Except for Indexed buffer mode (where one  
word counts messages) the remaining three words point to  
allocated data storage in shared RAM. After Master Reset is  
negated and before message processing, the host must  
initialize descriptor blocks for each utilized subaddress and  
mode code. Unused subaddresses and unimplemented  
mode codes may be illegalized (see below). The Descriptor  
Table Base Address Register is initialized with the starting  
address of the Descriptor Table. Multiple Descriptor Tabes  
can be used for fast context switching, with the active table  
designated by the base address register.  
Consistent, predictable terminal responses can be set up for  
all mode commands, including the reserved and undefined  
mode codes. An option bit in Configuration Register 1  
globally sets whether the 22 undefined mode commands are  
treated as illegal (RT response dependent on command’s  
Illegalization Table setting) or invalid (no RT response  
whatsoever, and no RTstatus change).  
HOLT INTEGRATED CIRCUITS  
6
HI-6120, HI-6121  
FUNCTIONAL OVERVIEW, Cont.  
Interrupt Log  
counter can be clocked from one of six internally generated  
frequencies, or from an external source. The user can  
enable automatic counter synchronization in response to  
“synchronize” mode commands, and optional host interrupts  
are provided for time-tag counter roll-over, and counter  
match to a stored value in theTime-Tag Utility register.  
The device maintains information from the last 16 interrupts  
in a 32-word circular buffer in shared RAM known as the  
Interrupt Log. Two 16-bit words characterize each interrupt;  
one word identifies the interrupt type (Interrupt Identification  
Word) and one word identifies the command that generated  
the interrupt (Interrupt Address Word). After reset, the  
Interrupt Log Address Register is reset to the fixed starting  
address of the 32 word Interrupt Log. After each occurring  
interrupt, the device updates the register to point to the log  
address used for the next occurring interrupt.  
Dual Bus Transceivers  
Built-in bus transceivers provide direct interface between  
the device and MIL-STD-1553 bus isolation transformers.  
The transceivers convert digital data to and from differential  
Manchester II encoded bus signals. A pair of “transmit  
inhibit” input pins exercises direct control over transmission  
for both buses.  
HARDWARE FEATURE SUMMARY  
Clock Inputs  
Encoder and Decoders  
A 50 MHz master clock input is required. The Time-Tag  
counter clock is selected from six internally generated  
frequencies, or may use an external clock input signal.  
The RT contains separate Manchester II encoders and  
decoders for each bus. Encoder-decoder logic interfaces  
directly with the dual-bus MIL-STD-1553 transceivers. The  
decoder checks for proper sync pulse and Manchester  
waveform, edge skew, correct number of bits and parity.  
During transmission, each encoded word is looped back  
through the decoder to check for errors. Bus sampling is  
clocked at 25 MHz, providing superior tolerance to zero-  
crossing distortion.  
Remote TerminalAddress Inputs  
The 5-bit Remote Terminal address is set using pins RTA0 to  
RTA 4. The RTAP input pin should be set or reset to present  
matching odd parity. The state of the RT address and parity  
pins is latched into the Operational Status register upon  
rising edge on the MR master reset input. The state of the  
LOCK input is latched into the Operational Status register at  
the same time, and controls whether or not the active  
terminal address and parity in the Operational Status  
register can be overwritten by host writes into the register.  
Between Master Reset assertions, the state of the RTA and  
RTAP inputs is “don’t care”. If the value of RT address and  
parity in the Operational Status register has parity error,  
terminal operation is disallowed.  
Auto-Initialization Serial EEPROM Interface  
The device has an automatic self-initialization feature. If self-  
initialization is enabled after MR master reset, the device  
reads configuration settings from external serial EEPROM  
to load the Descriptor Table, Illegalization Table, transmit  
mode command data and registers for terminal operation.  
Self-initialization can optionally initialize transmit data  
buffers with fixed data from EEPROM. A mechanism is  
provided to initially program or later modify the external  
serial EEPROM memory, by copying host-loaded tables and  
register values to the serial EEPROM.  
Integral Time-Tag Counter  
A free-running 16-bit counter provides time-tag values that  
are recorded for each message transacted. The time-tag  
MEMORY AND REGISTER ADDRESSING  
The HI-6120 and HI-6121 have an internal address space of  
32K 16-bit words. All memory addresses in this data sheet  
are expressed as hexadecimal numbers, using the C  
programming convention where the prefix “0x” denotes a  
hexadecimal value; e.g., 0x00FF represents 00FF hex.  
HI-6120 ONLY: When required by the application, the host  
bus interface HI-6120 is able to use byte transfers. All 8-bit  
microprocessors (and some 16-bit and 32-bit  
microprocessors) use (or can use) byte-oriented memory  
accesses. To provide byte capability, the HI-6120 has a  
sixteenth bus address input, A0. Byte oriented addressing  
with the HI-6120 uses all 16 address pins, A15 to A0 to  
address 64K bytes. TheA0 input denotes whether the first or  
second byte in the word is being addressed, while A15-A1  
indicate the word address. This difference must be  
considered when assigning HI-6120 pointer values or  
accessing RAM or registers. From the microprocessor’s  
standpoint, any host-assigned RAM buffer address will be  
double the value of the buffer’s pointer stored in RAM. This  
paragraph only applies to HI-6120 using 8-bit bus width.  
All device RAM and register address mapping is word  
oriented, rather than byte oriented. Register and memory  
addresses throughout this document reflect word  
addressing. For all HI-6121 and most HI-6120 applications,  
word oriented addressing applies. Word oriented  
addressing with the HI-6120 uses address inputs A15 to A1;  
address inputA0 is not used as fifteen bits are sufficient for a  
32K address range.  
HOLT INTEGRATED CIRCUITS  
7
HI-6120, HI-6121  
MEMORY AND REGISTER ADDRESSING, Cont.  
From this point on, all register and memory addresses  
presented in this data sheet are 15-bit word addresses.  
Addresses in the range 0x0020 to 0x7FFF apply to static  
RAM memory. All RAM is read-write and can be written or  
read by either the host or the internal device logic.  
From the host standpoint, register operations and RAM  
operations are performed identically. Registers occupy the  
lowest 32 addresses, 0x0 to 0x001F. Depending on function,  
individual registers may be read-only, read-write, or a  
combination of read-only and read-write bit fields. Read-only  
registers, and read-only bit fields contained in registers, are  
protected against accidental host overwrite by device logic.  
Some memory locations (specifically Descriptor Table  
Control Words) contain bits updated by both host and  
device. These locations are protected against accidental  
data collision by device arbitration logic which acts when  
concurrent writes by both host and device occur.  
0x7FFF  
Host-Allocated  
Subaddress Data Buffers.  
Comprising 97ꢀ of the memory  
address space, this RAM is  
allocated into subaddress  
data buffers by the  
Descriptor Table.  
0x0400  
0x03FF  
Descriptor Table.  
Defines terminal behavior  
for valid commands:  
how data is stored,  
host interrupts, etc.  
512 Words  
Multiple Descriptor Tables can be  
used for fast context switching.  
The active Descriptor Table is  
defined by the Descriptor Table  
Base Address Register.  
0x00FF  
Unallocated Memory.  
This space in shared RAM  
can be assigned by the host.  
160 Words  
0x0200  
0x01FF  
Illegalization Table.  
Initialized by the host, this table  
identifies illegal commands.  
256 Words  
0x0060  
0x005F  
0x0100  
0x00FF  
Interrupt Log Data Buffer.  
32 Words  
0x0040  
0x003F  
Expanded  
at Right  
Temporary Receive Data Buffer.  
32 Words  
0x0000  
0x0020  
0x001F  
Registers (listed on next page)  
32 Locations  
0x0000  
FIGURE 1. Address Mapping for Registers and RAM  
HOLT INTEGRATED CIRCUITS  
8
HI-6120, HI-6121  
REGISTERS  
Residing at the start of the memory address space, 32 addresses are reserved for HI-6120 and HI-6121 registers. Register  
addresses overlay the shared RAM address space, but are separate from the shared dual-port RAM.All register bits are active  
high. Unless otherwise indicated, all registers are reset in software to the logic zero condition after Master Reset (except any  
bits reflecting the state of input pins). For all registers, bit 15 is the most significant:  
Register  
Number  
Hex  
Address  
Register Name  
0
1
2
3
4
5
6
7
8
0x0000  
0x0001  
0x0002  
0x0003  
0x0004  
0x0005  
0x0006  
0x0007  
0x0008  
0x0009  
Configuration Register 1  
Configuration Register 2  
Operational Status Register  
Current Command Register  
Current Control WordAddress Register  
DescriptorTable BaseAddress Register  
Pending Interrupt Register  
1553 Status Word Bits Register  
Time-Tag Register  
Interrupt LogAddress Register  
Current Message Information WordAddress Register  
Reserved  
MemoryAddress Pointer (HI-6121 Only)  
Interrupt Enable Register  
Time-Tag Utility Register  
BusASelect Register  
Bus B Select Register  
9
10  
11-14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26-31  
0x000A  
0x000B-0x000E  
0x000F  
0x0010  
0x0011  
0x0012  
0x0013  
0x0014  
0x0015  
0x0016  
0x0017  
Built-InTest (BIT) Word Register  
Alternate Built-InTest (BIT) Word Register  
Reserved  
Test Control Register  
0x0018  
0x0019  
0x001A-0x001F  
LoopbackTestTransmit Data Register  
LoopbackTest Receive Data Register  
Reserved  
CONFIGURATION REGISTER 1 (0x0000)  
This 16-bit register is Read-Write and is fully maintained by the host.All bits are active high. This register is cleared after MR pin  
Master Reset. After SRSTsoftware reset, the SRSTbit is reset; the remaining bits are unchanged.  
INHBUIN  
S
H
A
BUIN  
S
T
B
SESLDSETLTCKT2TCKT1TCKS0TEXSRST  
BCSTUINMVCINOVTICSEM2CPSSRD8  
X
X
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
Bit No.  
Mnemonic Function  
INHBUSA BusA Inhibit.  
15  
When set, this bit disables transmit and receive for Bus A. This bit is logically ORed with the TXINHA  
input signal to control Bus A transmitter enablement. Bus A transmission is disabled if the INHBUSA  
register bit orTXINHAinput pin is asserted. TheTXINHApin does not affect the BusAreceiver.  
14  
13  
INHBUSB Bus B Inhibit.  
When set, this bit disables transmit and receive for Bus B. This bit is logically ORed with the TXINHB  
input signal to control Bus B transmitter enablement. Bus B transmission is disabled if the INHBUSB  
register bit orTXINHB input pin is asserted. TheTXINHB pin does not affect the Bus B receiver.  
INTSEL  
Interrupt Mode Select.  
When this bit is low, pulse interrupt outputs are selected for INTMES and INTHW output pins. When  
this bit is high, level interrupts are enabled which require host acknowledgment for interrupt pin reset.  
HOLT INTEGRATED CIRCUITS  
9
HI-6120, HI-6121  
REGISTERS, Cont.  
12  
SDSEL  
Shutdown Select.  
This bit affects terminal response to “transmitter shutdown” mode code commands and only applies  
when the MCOPT4 bit in Configuration Register 2 equals logic 0 for automatic shutdown after  
“transmitter shutdown” and “selected transmitter shutdown” mode code commands. When MCOPT4  
and SDSEL are both logic 0, a valid “transmitter shutdown” mode command automatically disables  
the inactive bus transmitter and receiver (complete ”bus shutdown”). This is the recommended  
mode of operation and is the default state of these two bits after MR reset.  
When MCOPT4 is logic 0 and SDSEL is logic 1, “transmitter shutdown” or “selected transmitter  
shutdown” mode commands automatically disable just the inactive bus transmitter, but the bus  
receiver remains enabled. The terminal fully complies with valid commands received on the  
inactive bus (storing received data, etc.), except it does not transmit status or data onto that bus  
(”mute terminal”). This mode of operation is not recommended but may be required in some  
applications. See MCOPT4 bit in Configuration Register 2 for further information concerning  
“transmitter shutdown” and “selected transmitter shutdown” mode commands. Also see Built-In Test  
(BIT) Word Register which contains status flags that reflect automatic shutdown status when the  
MCOPT4 bit in Configuration Register 2 is logic 0.  
11  
10  
9
TTCK2  
TTCK1  
TTCK0  
Time-Tag Counter Clock Select.  
These three bits select the time-tag counter clock source from the following options:  
TTCK2  
TTCK1  
TTCK0  
Clock Source  
Time-Tag counter disabled  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
External clock provided atTTCK input pin  
Internally generated 2us clock  
Internally generated 4us clock  
Internally generated 8us clock  
Internally generated 16us clock  
Internally generated 32us clock  
Internally generated 64us clock  
8
7
STEX  
Start Execution.  
Assertion of this bit initiates RT operation; negation of this bit inhibits or stops RT operation. Upon  
STEX assertion, RT parity-address error prevents terminal operation, regardless of the logical state  
of the STEX bit. If RT address parity error occurs, the Status Register and Pending Interrupt Register  
RTAPF bits will be asserted. This bit is cleared after MR pin master reset.  
SRST  
——  
Software Reset.  
Assertion of this bit immediately initiates the software reset process. This bit should not be set to logic  
1 during auto-initialization. This bit is cleared after MR master reset and automatically self-resets after  
being set by the host.  
6-5  
4
Not used.  
BCSTINV Broadcast Commands Invalid.  
If this bit is high, commands addressed to RT address 31 are treated as invalid: There is no terminal  
recognition of commands to RT address 31; there is no RT command response, and no status  
updating for the benefit of following “transmit status” or “transmit last command” mode commands. If  
this bit is low, commands addressed to RTaddress 31 are treated as valid broadcast commands.  
3
UMCINV Undefined Mode Codes Invalid.  
This bit globally defines whether undefined mode code commands are treated as valid (default) or  
invalid commands. This bit applies only to the following undefined mode code commands:  
Mode Codes 0 through 15 with T/R bit = 0  
Mode Codes16, 18 and19 withT/R bit = 0  
Mode Codes 17, 20 and 21 with T/R bit = 1  
If this bit is low (default state after MR pin reset) undefined mode code commands are considered  
valid, and RT response is based on individual mode command settings in the Illegalization Table: If a  
HOLT INTEGRATED CIRCUITS  
10  
HI-6120, HI-6121  
REGISTERS, Cont.  
mode command is legal, the RT “responds in form” and updates status. If a mode command is illegal,  
the RT asserts Message Error status and (if non-broadcast) transmits only its Status Word without  
associated data word. Later in this data sheet, the section “RT Message Responses, Options &  
Exceptions” fully describes terminal response for each mode code value, command word T/R bit  
state, and option settings.  
If this bit is high, undefined mode code commands are treated as invalid:There is no RTrecognition of  
an invalid command, no RT command response, and no status updating for the benefit of following  
“transmit status” or “transmit last command” mode commands.  
2
1
0
NOTICE2 If this bit is high, the terminal stores data associated with broadcast commands separately from data  
associated with non-broadcast commands to meet the requirements of MIL-STD-1553B Notice 2. If  
this bit is low, broadcast command data is stored in the same buffer as non-broadcast command data.  
SMCP  
Simplified Mode Command Processing.  
When asserted the device applies simplified processing for all valid mode code commands. The later  
section entitled “Mode Command Processing” describes this option.  
SSRD8  
Single-Strobe Read for 8-Bit Parallel Bus Mode.  
This bit only applies to HI-6120 (not HI-6121) and only applies when the parallel host bus is  
configured for 8-bit bus width. When performing 2-byte read accesses of external memory, some  
microprocessors with 8-bit bus assert individual Read Enable (or STROBE) pulses for high and low  
bytes. Other microprocessors assert a single, wider Read Enable (or STROBE) pulse, while simply  
changing the low address bit (A0 / LB) to access the two bytes. For this last case, the SSRD8 bit  
should be set when writing device configuration, before register or RAM readback is performed.  
CONFIGURATION REGISTER 2 (0x0001)  
This 16-bit register is Read-Write and is fully maintained by the host. All bits are active high. This register is cleared after MR  
pin Master Reset, but is unaffected by SRSTsoftware reset.  
G
A
T
TBITW  
OSELO1SEL0  
TRXD  
T
T
T
B
TLO  
R
AD  
T
AL MCOPMTC4OPT3 MCOMPTC1OPT0  
MCOPT2  
X
X
X
X
X
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
Bit No.  
Mnemonic Function  
15  
14  
TOSEL1  
TOSEL0  
Time-Out Select for RT-RTReceive Commands.  
These bits select the “no response” time-out for RT-RT receive commands. Message error occurs  
when the transmitting Remote Terminal fails to begin transmission before time-out occurs. Time  
interval boundaries are defined in RT validation test plan Figure 8 “RT-RT Timeout Measurement.”  
MIL-STD-1553B stipulates that 54 to 60us is the acceptable range for time-out. However, longer  
time-out options are provided for systems using long buses and/or utilizing bus repeaters that add  
delay to bus traffic. RT-RTtime-out can be selected from the following options:  
TOSEL1  
TOSEL0 RT-RT Time-Out  
1
1
0
0
1
0
1
0
150 us  
125 us  
100 us  
57 us  
(default after MR pin master reset)  
13  
TRXDB  
Temporary Receive Data Buffer.  
Setting this bit enables a temporary data buffer for all receive commands. When enabled, the RT  
stores received data words in a 32-word data buffer during message processing. Upon error-free  
message completion, all saved words are written to data buffer memory in a burst. When the  
temporary receive data buffer is disabled, the RT writes each received data word to the subaddress  
data buffer memory as it is received. Should message error occur during data word reception, this  
mode results in loss of data integrity, as vaild data from the prior command is partially overwritten by  
data from a message with error. MIL-STD-1553 states that data should be disregarded for messages  
HOLT INTEGRATED CIRCUITS  
11  
HI-6120, HI-6121  
REGISTERS, Cont.  
ending in error. This bit should only be modified while Configuration Register 1 STEX bit is low.  
Changes occurring while STEX = 1 cause unpredictable results. In a typical application, the buffer is  
not directly accessed by the host, although there is no restriction preventing host data access.  
12  
TTLOAD LoadTime-Tag Counter.  
When this bit is written from logic 0 to logic 1, data contained in the Time-Tag Utility register is written  
to the Time-Tag counter. The TTLOAD register bit self-resets after use. See MCOPT3 bit which  
affects automaticTime-Tag counter loading upon “synchronize” mode command with data word.  
11  
10  
RTTAG  
ResetTime-Tag Counter.  
Assertion of this bit clears the Time-Tag counter and counting is disabled until the bit is negated. Also  
the “synchronize” mode command (mode code 1) causes automaticTime-Tag counter reset.  
ALTBITW Alternate BITWord Enable.  
If this bit is logic 0, the device responds to a “transmit BIT word” mode command (MC19) by sending  
the word stored in the Built-In Test Word register, at address 0x0014. If this bit is logic 1, the terminal  
transmits the word stored in the Alternate Built-In Test Word register, at address 0x0015. The  
alternate register allows the user to fully define the BIT word, while the default register location  
contains several predefined, device-controlled status bits.  
9
MCOPT4 Mode Code Option 4.  
Note: Mode commands MC4 and MC5 are not affected by the MCOPT4 bit, but are included in this  
description to present a complete picture of device response to bus shutdown mode commands.  
The Bus Controller exercises “shutdown“ control over the terminal’s connection to the inactive MIL-  
STD-1553 bus using the “transmitter shutdown” (MC4) or “selected transmitter shutdown” (MC20  
decimal) mode code commands. When the inactive transmitter is shutdown, the HI-612x device  
inhibits further transmission on that bus. Once shutdown, the transmitter can be reactivated by (a) an  
“override transmitter shutdown” (MC5) mode command, (b) an “override selected transmitter  
shutdown” (MC21 decimal) mode command, (c) a “reset remote terminal” (MC8) mode command, (d)  
hardware MR master reset or (e) software reset by setting the SRSTbit in Configuration Register 1.  
When the MCOPT4 bit is reset, the device automatically performs bus shutdown and shutdown  
override in response to mode commands. When the MCOPT4 bit is set, the device only transmits  
status; the host must perform bus shutdown and override duties by asserting control of the TXINHA  
andTXINHB bits in Configuration Register 1, or by controlling the input pins with the same function.  
Mode commands MC4 (”transmitter shutdown”) and MC5 (”override transmitter shutdown”) have  
unconditional shutdown or override response. When MC4 is received, the terminal fulfills shutdown  
for the inactive bus, disabling the transmitter and receiver, or transmitter only, depending on the state  
of the SDSELbit in Configuration Register 1. The device affirms shutdown status by updating bits 15-  
12 in the BIT Word Register. When mode command MC5 is received, inactive bus transmit and  
receive is automatically reenabled by the device; “shutdown override” status is affirmed by resetting  
the inactive bus shutdown bit(s) in the BITWord Register.  
The “selected transmitter shutdown” (MC20 decimal) and “override selected transmitter shutdown”  
(MC21 decimal) mode commands act similarly to MC4 and MC5 respectively, except bus shutdown  
(or shutdown override) is conditional, based on the value of a mode data word received with the  
command. To act on a given bus, the received mode data word must match a predetermined “bus  
select” value. Bus shutdown (or shutdown override) can only act on the inactive bus, and only when  
the received mode data word matches the “bus select” value for that bus. When a MC20 mode data  
word matches the “bus select” value for the inactive bus, the terminal fulfills shutdown for the inactive  
bus, disabling the transmitter and receiver, or transmitter only, depending on the state of the SDSEL  
bit in Configuration Register 1. The device affirms shutdown status by updating bits 15-12 in the BIT  
Word Register. When a MC21 mode data word matches the “bus select” value for the inactive bus,  
the terminal fulfills shutdown override for the inactive bus, enabling the transmitter (and receiver, if  
the SDSEL bit in Configuration Register 1 is logic 0). The device affirms override status by resetting  
bits 15-12 in the BITWord Register.  
When the MCOPT4 bit equals zero, unique “bus select” values should be initialized by the host in the  
“Bus A Select” register (0x0012) and “Bus B Select” register (0x0013) for fulfillment of “selected  
HOLT INTEGRATED CIRCUITS  
12  
HI-6120, HI-6121  
REGISTERS, Cont.  
transmitter” shutdown and override mode commands. When MCOPT4 equals zero, transmitter  
shutdown (or shutdown override) automatically occurs when the received mode data value matches  
the inactive bus “Bus Select” register.  
This table shows device response for “transmitter shutdown” and “override transmitter shutdown”  
mode code commands for different option configurations:  
The MCOPT4 bit in Configuration Register 2 is logic 0 or 1  
MC4 (or MC5)  
unconditional  
fulfillment  
Inactive BusTx & Rx  
Disabled (Enabled).  
(only Tx is disabled, if the  
SDSELconfig. bit = 1)  
Status Word  
transmitted,  
unless  
In BITWord Register,  
TXSD & RXSD bits updated.  
(only TXSD bit updated, if the  
SDSELconfiguration bit = 1)  
broadcast.  
The MCOPT4 bit in Configuration Register 2 is logic 0  
MC20 ( or MC21)  
if mode data  
value matches  
“Bus Select ”value  
Inactive BusTx & Rx  
Disabled (Enabled).  
(only Tx is disabled, if the  
SDSELconfig. bit = 1)  
Status Word  
transmitted,  
unless  
In BITWord Register,  
TXSD & RXSD bits updated.  
(only TXSD bit updated, if the  
SDSELconfiguration bit = 1)  
broadcast.  
MC20 ( or MC21)  
if mode data  
does NOTmatch  
“Bus Select ”value  
Inactive BusTx & Rx  
status not changed  
Status Word  
transmitted,  
unless  
In BITWord Register, the  
TXSD & RXSD bits are static  
broadcast.  
The MCOPT4 bit in Configuration Register 2 is logic 1  
MC20 ( or MC21)  
if mode data  
value matches  
Inactive BusTx & Rx  
status NOTchanged  
(Host can modify BUSINH  
Status Word  
transmitted,  
unless  
In BITWord Register, the  
TXSD & RXSD bits are static.  
“Bus Select ”value bit in Configuration Reg 1)  
broadcast.  
MC20 ( or MC21)  
if mode data  
does NOTmatch  
“Bus Select ”value  
Inactive BusTx & Rx  
status NOTchanged  
Status Word  
transmitted,  
unless  
In BITWord Register, the  
TXSD & RXSD bits are static.  
broadcast.  
8
7
MCOPT3 Mode Code Option 3.  
MCOPT2 Mode Code Option 2.  
If both of these bits equal one, the data word received with a valid “synchronize” mode command  
(MC17) is unconditionally loaded into the Time-Tag counter. For non-broadcast MC17 commands,  
the counter load occurs before status word transmission. If both of these bits equal 0, the external  
host assumes responsibility for actions needed to perform “synchronize” duties upon reception of the  
valid MC17 “synchronize”mode code command, but status transmission automatically occurs.  
The binary 01 and 10 combinations of the MCOPT3 and MCOPT2 bits support certain extended  
subaddressing schemes. If the MCOPT3-MCOPT2 bits equal 01, the received data word is  
automatically loaded into the Time-Tag counter if bit 0 of the received data word equals 0. If the  
MCOPT3-MCOPT2 bits equal 10, the received data word is automatically loaded into the Time-Tag  
counter if bit 0 of the received data word equals 1. For non-broadcast MC17 commands, the  
counter load occurs before status word transmission.  
6
MCOPT1 Mode Code Option 1.  
If this bit is logic 0, reception of a “transmit vector word” mode command (MC16) causes automatic  
reset of the Service Request status bit. The Service Request bit is reset in the Status Word Bits  
HOLT INTEGRATED CIRCUITS  
13  
HI-6120, HI-6121  
REGISTERS, Cont.  
register before status word transmission begins. If the MCOPT1 bit is logic 1, the external host  
assumes responsibility for resetting the Service Request bit in the Status Word Bits register.  
5
MCOPT0 Mode Code Option 0.  
If this bit is logic 0, reception of a “reset remote terminal” mode command (MC8) causes automatic  
assertion of SRESET software reset. If non-broadcast mode command, reset occurs after status  
word transmission is complete. If this bit is logic 1, the external host assumes responsibility for  
actions needed to perform terminal reset.  
4-0  
——  
Not used.  
OPERATIONALSTATUS REGISTER (0x0002)  
All sixteen register bits are active high. After rising edge on the MR master reset input pin, bits 15 - 8 reflect the state of input  
pins RTA4 through RTA0, RTAP, LOCK andAUTOEN; register bits 7 - 3 are reset to logic 0 state. Register bits 8 - 0 are always  
read-only. If the register’s LOCK bit is logic 0, bits 15 - 9 are read-write but cannot be written unless STEX in Configuration  
Register 1 is low. If the register LOCK bit is logic 1, bits 15 - 9 are is read-only. Once the LOCK bit is set, unlock requires a new  
MR master reset assertion with the LOCK input pin at logic 0 state. This register is not affected by SRSTsoftware reset.  
OEN  
RT RT RT RT RT RT LOCKAUT READAYCTIVMECNDMCRDMCTDR  
4
3
2
1
0
P
A
A
A
A
A
A
APF  
T
EECKRFAMIF  
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
Bit No.  
Mnemonic Function  
15-11  
10  
RTA4 - 0  
RTAP  
RemoteTerminalAddress bits 4 - 0.  
RemoteTerminalAddress Parity.  
These bits contain the active remote terminal address. After a rising edge on the MR master reset  
input signal, these bits reflect the state of the RTA4 - 0 and RTAP input pins. When the register LOCK  
bit is high, these bits are read-only. When the register LOCK bit is low (and STEX in Configuration  
Register 1 equals 0) auto-initialization (see bit 8) or the host can overwrite these bits to change the  
terminal address and parity.  
9
8
LOCK  
TerminalAddress Lock.  
After a rising edge on the MR master reset input signal, this bit reflects the state of the LOCK input pin.  
When the LOCK bit is high, this bit is read-only. When LOCK is low (and STEX in Configuration  
Register 1 equals 0) auto-initialization (see bit 8) or the host can write this bit to logic 1 to lock the  
active terminal address.  
AUTOEN Auto-Initialize Enable.  
This read-only bit reflects the state of theAUTOEN input pin that applied at the rising edge on the MR  
master reset input signal. If the registerAUTOEN bit is high, device auto-initialization was performed  
following MR reset. When auto-initialization is complete, the device waits for the host to assert the  
STEX bit in Configuration Register 1 to enable terminal operation. Auto-initialization of the Control  
Register can optionally set STEX to begin terminal operation without host assistance. See section  
entitled “Reset and Initialization” for details.  
7
6
READY  
ACTIVE  
Ready status.  
This read-only bit reflects the state of the output pin READY and is cleared on reset. The bit is  
asserted after post-reset internal terminal initialization is complete, indicating that shared RAM is  
ready to accept configuration data from the host.  
Active status.  
When set, this read-only bit indicates the terminal is presently processing a message. This bit reflects  
the state of output pinACTIVE and is cleared on reset. Note: Ths bit and the corresponding output pin  
are asserted upon valid command detection and negated when command processing is completed.  
HOLT INTEGRATED CIRCUITS  
14  
HI-6120, HI-6121  
REGISTERS, Cont.  
5-3  
MCND  
MCRD  
MCTD  
Mode Code CommandType Flags (No-Data, Receive-Data andTransmit-Data).  
These three bits reflect the state of the command stored in the Current Command Register, 0x0003:  
Current Command Type  
Subaddress (not mode code)  
Mode code (no data word)  
Mode code (receive data)  
Mode code (transmit data)  
Mode code (undefined, no data)  
MCND MCRD  
MCTD  
Current Command Word  
0
1
0
0
1
0
0
1
0
1
0
0
0
1
1
Subaddress, transmit or receive  
MC0 to MC15, T/R bit equals 1  
MC16 to MC31, T/R bit equals 0  
MC16 to MC31, T/R bit equals 1  
MC0 to MC15, T/R bit equals 0  
2
1
RTAPF  
EECKF  
RTAddress Parity Fail.  
This bit is set when Remote Terminal address parity error is present. The bit is low when correct odd  
parity applies to the terminal address latched in bits 15-10. This bit is high when parity error is present.  
EEPROM Checksum Fail.  
This bit only applies when auto-initialization is enabled. While performing auto-initialization, this bit is  
set if the checksum tallied from read EEPROM data doesn’t match the checksum value stored in  
EEPROM. This failure also sets bit 1 in the Built-InTest Word Register (0x0014).  
0
RAMIF  
RAM Initialization Fail.  
This bit only applies when auto-initialization is enabled. While performing initialization, this bit is set if  
a write-then-read RAM value doesn’t match its counterpart location in the serial EEPROM. This  
failure also sets bit 1 in the Built-InTest Word Register (0x0014).  
CURRENT COMMAND REGISTER (0x0003)  
This 16-bit register is Read-Only and is fully maintained by the device. This register is cleared after MR pin master reset, but is  
not affected by SRSTsoftware reset.  
CURRENT COMMAND 15:0  
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
Bit No.  
Mnemonic Function  
CC15:0 Current Command Word.  
15-0  
This register contains the last valid command received over either MIL-STD-1553 bus. This register  
is updated 5us after theACTIVE output is asserted. Bit 15 is MSB.  
CURRENT CONTROLWORDADDRESS REGISTER (0x0004)  
This 16-bit register is Read-Only and is fully maintained by the device. This register is cleared after MR pin master reset, but is  
not affected by SRSTsoftware reset.  
CURRENT CONTROL WORD ADDRESS 15:0  
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
Bit No.  
Mnemonic Function  
15-0  
CCW15:0 Current Control WordAddress Register  
This register contains the address for the descriptor table Control Word corresponding to the current  
command stored in the Current Command Register (0x0003). This register is updated 5us after the  
ACTIVE output is asserted. Bit 15 is MSB. Also see “Current Message Information Word Address”  
register, 0x000A.  
HOLT INTEGRATED CIRCUITS  
15  
HI-6120, HI-6121  
REGISTERS, Cont.  
DESCRIPTOR TABLE BASEADDRESS REGISTER (0x0005)  
This 16-bit register is Read-Write and is fully maintained by the host. This register is loaded with 0x0200 after MR pin master  
reset or SRST software reset. The host maintains this register to specify the starting address for the Descriptor Table. For fast  
context switching, the host may initialize multiple Descriptor Tables, then update this register to load the new base address  
when the active Descriptor Table changes. The base address must be chosen with bits 7:0 = 00000000. These bits (and the  
highest address bit) cannot be set in the register. The primary Descriptor Table (enabled at reset) should reside at address  
space 0x0200 to 0x03FF. Other tables (if used) could begin at address multiples of 0x0200, like 0x0400 and 0x0600. Bit 15 and  
bits 7:0 cannot be set and will always read logic 0.  
DESCRIPTOR TABLE BASE ADDR 15:0  
0
A
A
A
A
A
A
A
0
0
0
0
0
0
0
0
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
PENDING INTERRUPT REGISTER (0x0006)  
This 16-bit register is Read-Only. It is cleared after MR pin master reset, but is not affected by SRST software reset. If the  
corresponding bit is set in the Interrupt Enable Register when a predetermined interrupt-causing event occurs, these actions  
occur: (1) a pending interrupt bit is set in this register, (2) the INTMES or INTHW output is asserted, depending on interrupt  
type, (3) the interrupt is registered in the Interrupt Log. To simplify host interrupt management, when the host reads this  
register, the Pending Interrupt Register automatically resets to 0x0000 and (if level interrupts are enabled by the INTSEL  
configuration bit) the INTMES and/or INTHW output pins are automatically negated. For further information on interrupt  
behavior, also see descriptions for Interrupt Enable register and Interrupt Log Address register, and refer to the later section  
entitled “Interrupt Management”.  
AIL  
A
APF  
A
IXEQZIW IBR  
T
MERR  
ILCM  
S
D
PIF LBF LBFB TTINTT1TINTR0  
EECKRFAMIF  
X
X
X
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
Bit No.  
Mnemonic Interrupt Type  
15  
IXEQZ  
Index Equal Zero Interrupt.  
If the IXEQZ bit is set in the Interrupt Enable register and the subaddress descriptor Control Word  
allows the IXEQZ interrupt, this bit is asserted for (a) subaddresses using indexed buffer mode when  
the index decrements from 1 to 0, or (b) subaddresses using circular buffer modes when the pre-  
determined number of messages has been transacted. The INTMES output is asserted and the  
Interrupt Log is updated.  
14  
13  
IWA  
IBR  
Interrupt WhenAccessed.  
If the IWAbit is set in the Interrupt Enable register and the subaddress descriptor Control Word allows  
the IWA interrupt, this bit is asserted each time a valid legal message is transacted for the  
subaddress. The INTMES output is asserted and the Interrupt Log is updated.  
Broadcast Command Received Interrupt.  
If the IBR bit is set in the Interrupt Enable register and the subaddress descriptor Control Word allows  
the IBR interrupt, this bit is asserted each time a valid legal broadcast message is transacted for the  
subaddress. The INTMES output is asserted and the Interrupt Log is updated.  
12-11  
10  
——  
Not used.  
MERR  
Message Error Interrupt.  
If the MERR bit is set in the Interrupt Enable register, this bit is asserted when a message error is  
detected. Errors can be caused by Manchester encoding problems or protocol errors. The INTMES  
output is asserted and the Interrupt Log is updated.  
9
8
——  
Not used.  
ILCMD  
Illegal Command Interrupt.  
If the ILCMD bit is set in the Interrupt Enable register, this bit is asserted each time an illegal message  
HOLT INTEGRATED CIRCUITS  
16  
HI-6120, HI-6121  
REGISTERS, Cont.  
(determined by the Illegalization Table) occurs for a new command. The INTMES output is asserted  
and the Interrupt Log is updated. See section entitled “Illegalization Table” for additional information.  
7
SPIFAIL  
SPI Fail Interrupt (HI-6121 only).  
The HI-6121 uses a SPI interface for host access. The device operates in SPI Slave mode. If the  
SPIFAIL bit is set in the Interrupt Enable register, this bit is asserted each time an incorrect number of  
SCK clocks occurs during SPI chip select assertion, The INTHW output is asserted and the Interrupt  
Log is updated.  
6-5  
LBFA, LBFB Loopback FailBusAand Loopback Fail Bus B Interrupts.  
During all transmitted command responses, the device compares words transmitted to the received  
and decoded words detected on the bus. If the LBFAor LBFB bit is set in the Interrupt Enable register,  
this bit is asserted each time this loopback detects mismatch. The INTMES output is asserted and the  
Interrupt Log is updated.  
4
3
2
TTINT1  
TTINT0  
RTAPF  
Time-Tag Interrupt 1.  
If the TTINT1 bit is set in the Interrupt Enable register, this bit is asserted each time the free-running  
Time-Tag counter value matches the value stored in the Time-Tag Utility Register. The INTHW output  
is asserted and the Interrupt Log is updated.  
Time-Tag Interrupt 0.  
If the TTINT0 bit is set in the Interrupt Enable register, this bit is asserted each time the free-running  
Time-Tag counter value rolls over from full count 0xFFFF to 0x0000. The INTHW output is asserted  
and the Interrupt Log is updated.  
RTAddress Parity Fail Interrupt.  
This bit is asserted when RT address and parity bits latched in the Operational Status Register do not  
exhibit odd parity (odd number of bits having logic 1 state). Because the RTAPF bit is always set in the  
Interrupt Enable register, the INTHW output is asserted and the Interrupt Log is updated. When parity  
error occurs, the RTwill not begin operation, regardless of the state of the Control Register STEX bit.  
1
0
EECKF  
RAMIF  
Initialization EEPROM Checksum Fail Interrupt.  
This bit is asserted if serial EEPROM checksum failure occurs during auto-initialization. Because the  
EECKF bit is always set in the Interrupt Enable register, the INTHW output is asserted and the  
Interrupt Log is updated.  
RAM Initialization Fail Interrupt.  
This bit is asserted after auto-initialization if an initialized RAM location does not match its 2  
corresponding serial EEPROM locations. Because the RAMIF bit is always set in the Interrupt Enable  
register, the INTHW output is asserted and the Interrupt Log is updated.  
1553 STATUS WORD BITS REGISTER (0x0007)  
This 16-bit register is Read-Write and is fully maintained by the host. The register is cleared after MR pin Master Reset or SRST  
software reset.All bits are active high. Bits set in this register are reflected in the outgoing MIL-STD-1553 status word.  
*
*
(ME) INST SVCREQ  
TXANDCLR  
(BCR)BUSYSSYSF  
TF  
* STATUS BIT AUTOMATICALLY  
CONTROLLED BY DEVICE  
0
0
0
0
0
0
0
0
0
0
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
The”dynamic bus control acceptance” bit is not implemented; this device cannot function as bus controller. The host controls  
the Instrumentation, Busy, Terminal Flag, Service Request and Subsystem Flag status word bits by writing to bits 9:0 in this  
register. Remote terminal status word responses reflects the assertion of these register bits until negated by the host, unless  
the Immediate Clear function (bit 15) is enabled. The position of register bits 4 and 10 correspond to the Broadcast Command  
Received (BCR) and Message Error (ME) bits in the terminal status word. Transmit state for the BCR and ME bits in the  
terminal’s status word is controlled by the device, based on prior command transactions. This pair of register bits cannot be set  
by a host write operation and always read back logic 0, so do not reflect the true status of these status flags.  
HOLT INTEGRATED CIRCUITS  
17  
HI-6120, HI-6121  
REGISTERS, Cont.  
Bit No.  
Mnemonic Status Bit or Function  
15  
TXANDCLR Transmit (Once) and Clear.  
When this bit is set, the register is cleared after any set bits 0-9 are used once in a transmitted status  
word. This bit does not affect operation of the Transmit Status Word and Transmit Last Command  
mode codes. Example: Transaction of a valid legal command with the INST and TXANDCLR bits  
asserted results in status word transmission with the Instrumentation bit set. If the following  
command is Transmit Status or Transmit Last Command mode code, the Instrumentation bit remains  
set.  
14-10  
9
——  
Not used, these bits cannot be set.  
INST  
Instrumentation.  
When this bit is asserted, the Instrumentation status bit is set.  
8
SVCREQ Service Request.  
When this bit is asserted, the Service Request status bit is set.  
7-4  
3
——  
Not used, these bits cannot be set.  
BUSY  
Busy (global).  
When this bit is asserted, the device asserts Busy bit in status response for all valid commands.  
Instead of globally enabling Busy status for all commands here, the host can assert Busy status for  
selected commands by asserting the Busy bit in descriptor table Control Words for the individual  
commands. When response to a command conveys Busy status, the device suppresses  
transmission of data words that would normally accompany status transmission. For any message  
transacted with Busy status, the WASBUSYflag is asserted in the stored Message Information Word.  
2
SSYSF  
Subsystem Flag.  
This register bit is logically ORed with the SSYSF input pin. If either SSYSF register bit or SSYSF pin  
is asserted, the SSYSF Subsystem Flag status bit is set. If the Configuration Register 2 MCOPT1 bit  
equals 0, reception of a “transmit vector word” mode command (MC16) causes automatic reset of the  
SSYSF status bit in this register; when this occurs, the register bit is reset before status word  
transmission begins.  
1
0
——  
TF  
Not used, this bit cannot be set.  
Terminal Flag.  
When this bit is asserted, theTerminal Flag status bit is set.  
TIME-TAG REGISTER (0x0008)  
This register is Read Only and is cleared after MR pin Master Reset or SRST software reset. Reads to this register address  
return the current value of the free running 16-bit Time Tag counter. Counter resolution is programmed by TTCK2:0 bits in  
Configuration Register 1. Options are: 2, 4, 8, 16, 32 and 64us, or externally provided clock.  
TIME-TAG COUNT 15:0  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
The device automatically resets the Time-Tag count when a “synchronize” mode command without data (MC1) is received. In  
addition, the host can reset theTime-Tag count at any time by asserting the RTTAG bit in Configuration Register 2.  
The MCOPT2 and MCOPT3 bits in Configuration Register 2 allow automatic loading of Time-Tag count using the data word  
received with a “synchronize with data” mode command, MC17. If both of these bits equal one, the data word received with a  
valid “synchronize” mode command (MC17) is unconditionally loaded into the Time-Tag counter. For non-broadcast MC17  
commands, the counter load occurs before status word transmission. If both MCOPT2 and MCOPT3 bits equal 0, the external  
host assumes responsibility for actions needed to perform “synchronize” duties upon reception of the valid MC17  
“synchronize” command, but status transmission automatically occurs.  
HOLT INTEGRATED CIRCUITS  
18  
HI-6120, HI-6121  
REGISTERS, Cont.  
The binary 01 and 10 combinations of the MCOPT2 and MCOPT3 bits support certain extended subaddressing schemes. If  
the MCOPT3-MCOPT2 bits equal 01, the received data word is automatically loaded into the Time-Tag counter if the low  
order bit of the received data word (bit 0) equals 0. If the MCOPT3-MCOPT2 bits equal 10, the received data word is  
automatically loaded into the Time-Tag counter if the low order bit of the received data word (bit 0) equals 1. For non-  
broadcast MC17 commands, the counter load occurs before status word transmission. .  
INTERRUPT LOGADDRESS REGISTER (0x0009)  
This 16-bit register is Read-Only and is fully maintained by HI-6120 logic. The register contains 0x0040 after MR pin master  
reset but is not affected by SRST software reset. Bits 7:0 contain an address pointer for the 32-word Interrupt Log Buffer  
located in shared RAM. The value in Interrupt Log Address register bits 7:0 indicates the storage address where interrupt  
information words will be stored for the next occurring interrupt, 0x40 - 0x5E. The value is always even since two words are  
stored for each interrupt.  
Bits 15:8 contain a count value for the number of interrupts logged (0 - 255) since the Interrupt Log Address Register was last  
read. The count increment stops at 255. Bits 15:8 are reset automatically after this register is read by the host.  
INTERRUPT  
COUNT 7:0  
INTERRUPT LOG  
ADDRESS 7:0  
C
C
C
C
C
C
C
C
0
1
0
A
A
A
A
0
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
To help the host process interrupts, the device maintains information from the 16 most recent interrupts in a 32-word ring buffer  
in shared RAM, found at address range 0x0040 to 0x005F. Each interrupt stores two information words: the Interrupt  
Identification Word (IIW) identifies the interrupt type(s) that occurred; the Interrupt Address Word (IAW) identifies the interrupt  
source. For interrupts that result from message processing, the IAW contains the 16-bit address of the command’s Control  
Word in the DescriptorTable. For hardware interrupts, the IAW value is 0x0000.  
After MR master reset, the device automatically resets this register to 0x0040, an interrupt count of zero and log address of  
0x40. During terminal operation, the host can read bits 15:8 to see the number of interrupts logged in the buffer since the last  
read operation upon the register. Information words for the sixteenth interrupt are stored in buffer addresses 0x005E and  
0x005F, and the Interrupt LogAddress “rolls over” to read 0x40, where interrupt information for the seventeenth interrupt will be  
stored. For further information on interrupts, see descriptions for the Interrupt Enable register, the Pending Interrupt register,  
and see the later section entitled “Interrupt Management”.  
CURRENT MESSAGE INFORMATION WORDADDRESS REGISTER (0x000A)  
This 16-bit register is Read-Only and is fully maintained by the device. This register is cleared after MR pin master reset, but is  
not affected by SRSTsoftware reset. Also see “Current Control WordAddress” register, 0x0004.  
CURRENT MSG INFO WORD ADDRESS 15:0  
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
Bit No.  
Mnemonic Function  
15-0  
MIWA15:0 Current Message Information WordAddress Register  
This register contains the data buffer address for the last command’s Message Information Word, or  
MIW, corresponding to the current command stored in the Current Command Register (0x0003).  
This register is updated 5us after theACTIVE output is asserted. Bit 15 is MSB.  
MEMORYADDRESS POINTER REGISTER (HI-6121 ONLY) (0x000F)  
This register is Read-Write and is cleared after MR pin master reset, but is not affected by SRST software reset. This register is  
maintained by the host. The contained value is a memory address used when fulfilling RAM or register read or write operations  
via the HI-6121 Serial Peripheral Interface (SPI). See data sheet section, ”Host Serial Peripheral Interface (SPI)” for further  
details. For HI-6120 devices, writes to this address have no effect; the address reads back 0x0000 if a host read cycle occurs.  
HOLT INTEGRATED CIRCUITS  
19  
HI-6120, HI-6121  
REGISTERS, Cont.  
MEMORY ADDRESS 15:0  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
INTERRUPT ENABLE REGISTER (0x0010)  
This 16-bit register is Read-Write (except bits 2-0 are read only) and is fully maintained by the host. All bits are active high.  
After rising edge on the MR Master Reset input, the register is automatically initialized to 0x0007. This register is unaffected by  
SRST software reset. For further information on interrupts, see descriptions for the Pending Interrupt and Interrupt Log  
Address registers, and refer to the later section entitled “Interrupt Management”.  
AIL  
A
APF  
A
IXEQZIW IBR  
T
MERR  
ILCM  
S
D
PIF LBF LBFB TTINTT1TINTR0  
EECKRFAMIF  
X
X
X
1
1
1
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
An interrupt type is globally disabled when the corresponding bit in this register is reset. This allows the external host or  
subsystem to temporarily disable interrupt servicing for some or all interrupts. While an interrupt enable bit is negated, the  
terminal does not generate an interrupt output signal for the corresponding interrupt event. Note: Asserting an interrupt bit in  
this register after an event occurs does not generate an interrupt for that event. For some interrupts that result from message  
processing, interrupt enable bits in a each command’s descriptor Control Word act in combination with settings in this register  
to respond appropriately to interrupt-causing events:  
Bit No.  
Mnemonic Interrupt Type  
15  
IXEQZ  
Index Equal Zero Interrupt.  
When this bit is asserted, interrupts are globally enabled for (a) subaddresses using indexed buffer  
mode when the index decrements from 1 to 0, and (b) subaddresses using a circular buffer mode  
when the pre-determined number of messages has been transacted. When this bit is asserted,  
occurrence of an IXEQZ event (a) or (b) causes INTMES output assertion (if the IXEQZ bit is set in the  
command’s descriptor Control Word).  
14  
13  
IWA  
IBR  
Interrupt WhenAccessed Interrupt.  
When this bit is asserted, interrupts are globally enabled for each message occurrence to  
subaddresses in which the Descriptor Control Word allows the IWA interrupt. When this bit is  
asserted, occurrence of an IWA event causes INTMES output assertion (if the IWA bit is set in the  
command’s descriptor Control Word).  
Broadcast Command Received Interrupt.  
When this bit is asserted, interrupts are globally enabled for each broadcast message to  
subaddresses in which the Descriptor Control Word allows the IBR interrupt. When this bit is  
asserted, occurrence of an IBR event causes INTMES output assertion (if the IBR bit is set in the  
command’s descriptor Control Word).  
12-11  
10  
——  
Not used.  
MERR  
Message Error Interrupt.  
When this bit is high, the INTMES interrupt output is asserted when a message error is detected.  
Errors are caused by Manchester encoding problems or protocol errors. Interrupt assertion occurs  
whenever the terminal sets the ME “message error” bit in the terminal’s status word. The detected  
error type can be found in Message Information Word stored as a result of message processing.  
9
8
——  
Not used.  
ILCMD  
Illegal Command Interrupt.  
Illegal commands are defined in the Illegalization Table. When enabled, the ILCMD interrupt is  
asserted when the Illegalization Table bit corresponding to the received command is logic 1. The  
Illegalization Table should only contain nonzero values when “illegal command detection” is being  
HOLT INTEGRATED CIRCUITS  
20  
HI-6120, HI-6121  
REGISTERS, Cont.  
applied. When illegal commands are received, the terminal responds by transmitting status word with  
ME “message error” flag set; no data words are transmitted. If this ILCMD bit is high, all illegal  
commands cause INTMES interrupt output assertion. See next section entitled “Pending Interrupt  
Register” (below) and the section entitled “Illegalization Table” for further information.  
7
SPIFAIL  
SPI Fail Interrupt (HI-6121 only).  
The HI-6121 uses a SPI interface for host access. The device operates in SPI Slave mode. When  
this bit is high, the INTHW output is asserted and the Interrupt Log is updated each time an incorrect  
number of SCK clocks occurs during SPI chip select assertion.  
6-5  
LBFA, LBFB Loopback Fail BusAand Loopback Fail Bus B Interrupts.  
During all transmitted command responses, the device compares words transmitted to the received  
and decoded words detected on the bus. When this bit is high, the INTMES output is asserted and the  
Interrupt Log is updated each time loopback detects word mismatch.  
4
TTINT1  
TTINT0  
Time-Tag Interrupt 1.  
If this bit is logic 1, the INTHW interrupt output is asserted and the TTINT1 bit is set in the Pending  
Interrupt register each time the free-running Time-Tag counter value matches the value stored in the  
Time-Tag Utility Register.  
3
Time-Tag Interrupt 0.  
If this bit is logic 1, the INTHW interrupt output is asserted and the TTINT0 bit is set in the Pending  
Interrupt register each time the free-running Time-Tag counter value rolls over from 0xFFFF full count  
to 0x0000.  
2
1
0
RTAPF  
EECKF  
RAMIF  
RTAddress Parity Fail Interrupt.  
When this bit is high, the INTHW interrupt is asserted when RT address parity error is detected. This  
bit is 1 after MR master reset and cannot be reset by host register write.  
Initialization EEPROM Checksum Fail Interrupt.  
When this bit is high, the INTHW interrupt is asserted if serial EEPROM checksum failure occurs  
during auto-initialization. This bit is 1 after MR master reset and cannot be reset by host register write.  
RAM Initialization Fail Interrupt.  
When this bit is high, the INTHW interrupt is asserted after auto-initialization if an initialized RAM  
location does not match its 2 corresponding serial EEPROM locations. This bit is 1 after MR master  
reset and cannot be reset by host register write.  
The Interrupt Enable Register lets the host temporarily or permanently disable interrupt servicing for some or all interrupt  
types. When bits are reset in this register, interrupt output signals are globally disabled for the corresponding interrupt types.  
Asserting a bit in the Interrupt Enable register after an event occurs does not generate an interrupt for that event. The IXEQZ,  
IWA and IBR interrupts result from message processing. The host can enable or disable these three interrupt types for  
individual subaddresses and mode code commands by setting or resetting the IXEQZ, IWA and IBR bits in descriptor table  
Control Words corresponding to each subaddress or mode command. While the ILCMD and MERR interrupts also result from  
message processing, these interrupts (along with all hardware interrupts) are globally enabled or disabled, and are unaffected  
by descriptor table settings. Here is a summary of settings and responses to interrupt-causing messages:  
Descriptor Control Word Interrupt Enable Register  
Bit for Interrupt Type  
Effect on Corresponding Bit  
in Pending Interrupt Register  
Is Interrupt Output  
Signal Generated?  
IXEQZ, IWA& IBR bits  
Reset  
Set  
Set  
Don’t Care  
Reset  
Set  
No Change  
No Change  
Pending Int. Register bit is set  
No  
No  
Yes  
All Interrupts Except  
IXEQZ, IWAand IBR  
(no Control Word bits)  
Reset  
Set  
Pending Int. Register bit is set  
Pending Int. Register bit is set  
No  
Yes  
HOLT INTEGRATED CIRCUITS  
21  
HI-6120, HI-6121  
REGISTERS, Cont.  
TIME-TAG UTILITYREGISTER (0x0011)  
This 16-bit register is Read-Write and is fully maintained by the host.This register is cleared after MR pin master reset, but is not  
affected by SRSTsoftware reset. This register has two functions associated with the free-runningTime-Tag counter:  
TIME-TAG UTILITY 15:0  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
Function 1: When Configuration Register 2 is written causing a 0 to 1 transition of the TTLOAD bit, the value contained in the  
Time-Tag Utility register is loaded into theTime-Tag counter.  
Function 2: If the TTINT1 bit in Configuration Register 2 and the TTINT1 bit in the Interrupt Enable register are both set, the  
Interrupt Pending register TTINT1 bit is set and the INTHW interrupt output is asserted each time the free-running Time-Tag  
counter value matches the value stored in theTime-Tag Utility register.  
BUSASELECT REGISTER (0x0012)  
This 16-bit register is Read-Write and is fully maintained by the host. This register is cleared after MR pin master reset, but is not  
affected by SRST software reset. The Bus A Select register is only used when the MCOPT4 bit in Configuration Register 2  
equals 0. This MCOPT4 setting means the device automatically fulfills mode commands MC20 (decimal) “selected transmitter  
shutdown” or MC21 “override selected transmitter shutdown”.  
BUS A SELECT REGISTER 15:0  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
“Transmitter shutdown” or “shutdown override” can only occur for the inactive bus. If either mode command is received on Bus  
B, the inactive bus is Bus A. The device compares the received mode data word to the contents of the Bus A Select register to  
determine whether inactive Bus A is selected for “transmitter shutdown” or “transmitter shutdown override”. (Bus shutdown or  
shutdown override can only occur for the inactive bus.) If the data word matches the value stored in the Bus A Select register  
and MCOPT4 equals 0, the device automatically fulfills MC20 “transmitter shutdown” or MC21 “shutdown override” without  
host assistance: If the mode command received was MC20, the Transmit Shutdown A bit in the built-in test (BIT) word is  
asserted. If mode command MC21 was received, the Transmit Shutdown A bit in the BIT Word is negated. Refer to  
Configuration Register 2 description of MCOPT4 bit for additional details.  
BUS B SELECT REGISTER (0x0013)  
This 16-bit register is Read-Write and is fully maintained by the host.This register is cleared after MR pin master reset, but is not  
affected by SRST software reset. The Bus B Select register is only used when the MCOPT4 bit in Configuration Register 2  
equals 0. This MCOPT4 setting means the device automatically fulfills mode commands MC20 (decimal) “selected transmitter  
shutdown” or MC21 “override selected transmitter shutdown”.  
BUS B SELECT REGISTER 15:0  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
“Transmit shutdown” or “shutdown override” can only occur for the inactive bus. If either mode command is received on BusA,  
the inactive bus is Bus B. The device compares the received mode data word to the contents of the Bus B Select register to  
determine whether inactive Bus B is selected for “transmitter shutdown” or “transmitter shutdown override”. If the data word  
matches the value stored in the Bus B Select register and MCOPT4 equals 0, the device automatically fulfills MC20 “transmit  
shutdown” or MC21 “shutdown override” without host assistance: If the mode command received was MC20, the Transmit  
Shutdown B bit in the built-in test (BIT) word is asserted. If mode command MC21 was received, the Transmit Shutdown B bit in  
the BITWord is negated. Refer to Configuration Register 2 description of MCOPT4 bit for additional details.  
HOLT INTEGRATED CIRCUITS  
22  
HI-6120, HI-6121  
REGISTERS, Cont.  
BUILT-IN TEST WORD REGISTER (0x0014)  
Bits 4-11 in this 16-bit register are read-write, the remaining bits are read-only. The ten assigned bits are written by the device  
when predetermined events occur. The host may overwrite the device-written bits 5 and 4. After MR pin master reset, bits 13-  
12, 5-4 and 0 are reset. Bits 15-14 will be set if the corresponding TXINHA or TXINHB input pins are high. Bits 3-1 will be set if  
RT address parity error, or post-MR memory test or auto-initialization failure occurred. This register is cleared by SRST  
software reset.  
UNASSIGNED BITS  
ARE USER DEFINED  
A
APF  
T
TXASTDXBSRDXASRDXBSD  
BLBFBLBFBMTFR  
EELFTFBINH  
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
If the ALTBITW option bit in Configuration Register 2 is zero when a valid “transmit BIT word” mode command (MC19) is  
received, the current value in this register is transmitted as the mode data word in the terminal response. The value is also  
copied to the assigned data buffer for MC19, after mode command fulfillment.  
Bit No.  
Mnemonic Interrupt Type  
15  
14  
TXASD  
TXBSD  
TransmitterAShut Down.  
Transmitter B Shut Down.  
These read-only bits are set when the corresponding bus transmitter was disabled by assertion of the  
bus TXINHA or TXINHB input pin, or by fulfillment of a “transmitter shutdown” mode command MC4  
or MC20. Refer to the description for the SDSELbit in Configuration Register 1 and the description for  
the MCOPT4 bit in Configuration Register 2 for further information.  
13  
12  
RXASD  
RXBSD  
ReceiverAShut Down.  
Receiver B Shut Down.  
These read-only bits are set when the corresponding bus receiver was disabled concurrently with the  
bus transmitter by a “transmitter shutdown” mode command MC4 or MC20. Refer to the description  
for the SDSELbit in Configuration Register 1 and the description for the MCOPT4 bit in Configuration  
Register 2 for further information.  
11-6  
5
——  
User assigned bits.  
BLBFA  
BISTLoopback Fail BusA.  
This bit is set if BusAloopback failure error occurs during built-in self-test.  
4
3
2
BLBFB  
BMTF  
BISTLoopback Fail Bus B.  
This bit is set if Bus B loopback failure error occurs during built-in self-test.  
BISTMemoryTest Fail.  
This bit is set if error occurs during built-in self-test for device RAM memory.  
RTAPF  
RTAddress Parity Failure.  
This bit is asserted when Operational Status Register bits 15:10 reflect parity error. After MR master  
reset, bits 15:10 in the Operational Status Register reflect input pin states, but will be overwritten if  
subsequent auto-initialization is performed (if AUTOEN pin is high) and the initialization EEPROM  
contains different data for Operational Status Register bits 15:10.  
1
0
EELF  
Auto-Initialization EEPROM Load Fail.  
This bit only applies when auto-initialization is enabled (AUTOEN input pin state equals 1). This bit is  
set if, after MR master reset, failure occurs when copying serial EEPROM to registers and RAM.  
When this occurs, bit 0 or bit 1 will be set in the Operational Status Register (0x0002) to indicate type  
of failure.  
TFBINH  
Terminal Flag Bit Inhibited.  
This bit is set when the Terminal Flag status bit is disabled while fulfilling an “inhibit terminal flag bit”  
mode code command (MC6). This bit is reset if terminal flag status bit disablement is later cancelled  
by an “override inhibit terminal flag bit” mode code command (MC7).  
HOLT INTEGRATED CIRCUITS  
23  
HI-6120, HI-6121  
REGISTERS, Cont.  
ALTERNATE BUILT-IN TEST WORD REGISTER (0x0015)  
This 16-bit register is Read-Write and is fully maintained by the external host. This register is cleared after MR pin master reset  
but unaffected by SRSTsoftware reset.  
ALTERNATE BUILT-IN TEST WORD REGISTER 15:0  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
If the ALTBITW option bit in Configuration Register 2 equals one when a valid “transmit BIT word” mode command (MC19) is  
received, the current value in this register is transmitted as the mode data word in the terminal response. The value is also  
copied to the assigned data buffer for MC19, after mode command fulfillment.  
RESERVED REGISTER (0x0016)  
Register 0x0016 is used for factory testing. It is cleared after MR pin master reset and cannot be written by the host while the  
TESTinput pin is low.  
TEST CONTROLREGISTER (0x0017)  
This register controls RAM built-in self-test, and transceiver loopback testing. Bits 3-4 and 8-9 are Read Only. The remaining  
bits in this register are Read-Write but can be written only when the TEST input pin is high. This register is cleared after MR pin  
master reset, or SRST software reset. This register supports two types of test: Register bits 15 - 8 are used for RAM built-in self  
test (RAM BIST). Register bits 7 -2 are used for transceiver loopback testing (either digital loopback or analog loopback).  
T
AR  
T
AIL  
ASS  
AIL  
ASS  
AIL  
FRAMRABFFRBSERLB2SERLB1SERL0BSTRRBP RBF  
LBALOLBGSYLNBCBULSBESLTLBP LBF  
0
0
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
Under internal logic control, this device uses one RAM self test (Inc / Dec Test described below) to check internal RAM memory  
after MR pin master reset. Test Control Register bits 15 - 8 provide a means for the host to perform RAM self-test at other times.  
Register bits 13:11 select RAM test type. Then bit 10 starts the selected RAM test, and bits 9-8 report a pass/fail result after test  
completion.All tests are destructive, overwriting data present before test commencement.  
Bit No.  
Mnemonic Interrupt Type  
15  
FRAMA Full RAMAccess Enable.  
During normal operation, some bits in certain RAM locations (e.g., Descriptor Table Control Words)  
cannot be written by the host. When the FRAMA bit is asserted, host writes to RAM are unrestricted  
to permit full testing. During normal completion, this bit must be reset to logic 0.  
14  
RBFFAIL RAM BISTForce Failure.  
When this bit is asserted, RAM test failure is forced to verify that RAM BISTlogic is functional.  
13-11  
RBSEL2-0 RAM BISTSelect Bits 2-0.  
This 3-bit field selects the RAM BISTtest mode applied when the RBSTARTbit is set:  
RBSEL2:0 SELECTED RAM TEST  
TEST TIME  
000  
001  
010  
011  
100  
101  
110  
111  
Idle  
PatternTest, described below . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.42ms  
Write 0x0000 to RAM address range 0x0000 - 0x7FFF . . . . . . . . . . . . 170us  
Read and verify 0x0000 over RAM address range 0x0000 - 0x7FFF . . . 500us  
Write 0xFFFF to RAM address range 0x0000 - 0x7FFF . . . . . . . . . . . . 170us  
Read and verify 0xFFFF over RAM address range 0x0000 - 0x7FFF . . 500us  
Inc / DecTest performs only steps 5 - 8 of the PatternTest below . . . . . . 1.32ms  
Idle  
HOLT INTEGRATED CIRCUITS  
24  
HI-6120, HI-6121  
REGISTERS, Cont.  
Description of the RAM BIST “PATTERN” test selected when register bits RBSEL2:0 = 001:  
Note: Test read /write accesses to addresses 0x0000 - 0x001F involve 32 RAM locations not  
accessible to the host. These accesses do not affect the host-accessible registers, overlaying the  
same address range.  
1. Write 0x0000 to all RAM locations, 0x0000 through 0x7FFF  
2. Repeat the following sequence for each RAM location from 0x00000 through 0x7FFF:  
a. Read and verify 0x0000  
b. Write then read and verify 0x5555  
c. Write then read and verify 0xAAAA  
d. Write then read and verify 0x3333  
e. Write then read and verify 0xCCCC  
f. Write then read and verify 0x0F0F  
g. Write then read and verify 0xF0F0  
h. Write then read and verify 0x00FF  
I. Write then read and verify 0xFF00  
j. Write 0x0000 then increment RAM address and go to step (a)  
3. Write 0xFFFF to all RAM locations, 0x0000 through 0x7FFF  
4. Repeat the following sequence for each RAM location from 0x00000 through 0x7FFF:  
a. Read and verify 0xFFFF  
b. Write then read and verify 0x5555  
c. Write then read and verify 0xAAAA  
d. Write then read and verify 0x3333  
e. Write then read and verify 0xCCCC  
f. Write then read and verify 0x0F0F  
g. Write then read and verify 0xF0F0  
h. Write then read and verify 0x00FF  
I. Write then read and verify 0xFF00  
j. Write 0xFFFFthen increment RAM address and go to step (a)  
5. Write each cell’s memory address into each RAM location from 0x00020 to 0x7FFF  
6. Read each memory location from 0x00000 to 0x7FFF and verify it contains its address  
7. Write 1s complement of each cell’s memory address, into each RAM location (same addr range)  
6. Read each memory location and verify it contains the 1s complement of its address  
10  
RBSTRT RAM BISTStart.  
Writing logic 1 to this bit initiates the RAM BIST test selected by register bits RBSEL2:0. The RBSTRT  
bit can only be set if the TEST input pin is high and if register bit 15 is already asserted. This bit is  
automatically cleared upon test completion. Register bits 9-8 indicate pass / fail test result.  
9
8
RBPASS RAM BISTPass.  
Device logic asserts this bit when the selected RAM test completes without error. This bit is  
automatically cleared when RBSTRTbit 10 is set.  
RBFAIL  
RAM BISTFail.  
Device logic asserts this bit when failure occurs while performing the selected RAM test. This bit is  
automatically cleared when RBSTRT bit 10 is set. When BIST failure occurs, a clue to the failing RAM  
address can be read at register address 0x001E. For speed, the RAM BIST concurrently tests 4  
quadrants of the RAM address range, in parallel. If test failure occurs, register address 0x001E  
contains the RAM address being tested in the lowest RAM quadrant.Actual failure will occur in any of  
these four locations: at RAM address “ADDR” stored in register 0x001E, or ADDR+0x2000, or  
ADDR+0x4000 orADDR+0x6000.  
7-6  
5
——  
Not Used.  
LBALOG LoopbackTestAnalog.  
The device supports either digital or analog loopback testing for either bus transceiver. When the  
LBALOG bit is low, digital loopback is selected and no data is transmitted onto the selected external  
MIL-STD-1553 bus. When the LBALOG bit is high, analog loopback is selected and a test word is  
HOLT INTEGRATED CIRCUITS  
25  
HI-6120, HI-6121  
REGISTERS, Cont.  
transmitted onto and received from the selected external MIL-STD-1553 bus.  
4
3
2
LBSYNC LoopbackTest Word Sync Select.  
When the LBSYNC bit is high, the loopback test word is transmitted with command sync. When the  
LBSYNC bit is low, the loopback test word is transmitted with data sync.  
LBBUSEL LoopbackTest Bus Select.  
When this bit is low, loopback testing occurs on Bus A. When this bit is high, loopback testing occurs  
on Bus B.  
LBSTART LoopbackTest Start.  
Writing logic 1 to this bit initiates the loopback test selected by register bits 2, 6 and 7. The LBSTRT bit  
can only be set if the external TEST pin is already asserted, and is automatically cleared upon test  
completion. Register bits 3-4 indicate pass / fail test result.  
1
0
LBPASS  
LBFAIL  
LoopbackTest Pass.  
Device logic asserts this bit when the selected RAM test completes without error. This bit is  
automatically cleared when LBSTRTbit 5 is set.  
LoopbackTest Fail.  
Device logic asserts this bit when failure occurs while performing the selected loopback test. Failure  
is comprised of Manchester encoding error, parity error, wrong sync type or data mismatch. This bit is  
automatically cleared when LBSTRTbit 5 is set.  
LOOPBACK TEST TRANSMIT DATAREGISTER (0x0018)  
This 16-bit register is Read-Write and is fully maintained by the host. This register is cleared after MR pin master reset, but is not  
affected by SRST software reset. The value contained in this register is used when performing digital loopback testing. See  
Test Control Register, 0x0016, for additional information.  
LOOPBACK TEST TRANSMIT DATA REGISTER 15:0  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
LOOPBACK TEST RECEIVE DATAREGISTER (0x0019)  
This 16-bit register is Read-Only. This register is cleared after MR pin master reset, but is not affected by SRST software reset.  
Data is written to this register when performing digital loopback testing. See Test Control Register, 0x0016, for additional  
information.  
LOOPBACK TEST RECEIVE DATA REGISTER 15:0  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
COMMAND RESPONSES  
Abrief review of MIL-STD-1553 commands and responses  
is appropriate here to establish terminology used in the  
rest of this data sheet. Shown in Figure 2, each command  
word is comprised of a sync field, three 5-bit data fields, a  
single bit denoting Transmit / Receive direction and ends  
with a parity bit. The hardware decoder uses the sync field  
to determine word type (command vs. data). Word validity  
is based on proper sync encoding, Manchester II  
encoding, correct bit count and correct odd parity for the 16  
data bits. Once a valid word with command sync is found,  
the sync and parity are stripped before the command’s 16  
data bits are stored for further processing.  
HOLT INTEGRATED CIRCUITS  
26  
HI-6120, HI-6121  
COMMAND RESPONSES, Cont.  
Command  
Sync  
T/R  
Bit  
Word Count  
Field *  
* Word Count field is replaced by Mode Code  
field when the SA field equals 0x00 or 0x1F  
Terminal  
Address  
Field  
Subaddress  
(SA) Field  
Parity  
Bit  
FIGURE 2. MIL-STD-1553 Command Word Structure  
commands ” in MIL-STD-1553B:  
Mode Codes 0 through 15 with T/R bit = 0  
A “valid command” can be specifically addressed to the  
individual HI-6120 terminal (the command word’s  
embedded Terminal Address field matches the terminal  
address latched in the Operational Status register) or can  
be a “broadcast command” addressed to all terminals.  
Broadcast commands are always addressed to RT  
address 31 (0x1F). In systems where broadcast  
commands are disallowed, RT31 is not used as a  
conventional terminal address. When set, the BCSTINV bit  
in Configuration Register 1 renders RT31 commands as  
“invalid”: broadcast commands are indistinguishable from  
commands addressed to other terminals. Invalid  
commands are simply disregarded.  
Mode Codes16, 18 and19 with T/R bit = 0  
Mode Codes 17, 20 and 21 with T/R bit = 1  
The UMCINV bit in Configuration Register 1 determines  
how these undefined mode commands are handled by the  
HI-6120. If the UMCINV configuration bit equals 1, the  
undefined mode commands are treated as invalid. They  
are not recognized by the device. There is no terminal  
response and status is not updated. If the UMCINV  
configuration bit equals 0, the 22 undefined mode  
commands are considered valid; this is the default  
condition following reset. For this case, terminal response  
depends on whether or not the application uses “illegal  
command detection:”  
When the command word’s 5-bit SA(subaddress) field is in  
the range of 1 to 30 (0x01 to 0x1E) the command is  
considered a “subaddress command”. The terminal will  
either receive or transmit data words, and “direction” is  
specified by the command’s T/R bit. The number of data  
words transacted is specified in the 5-bit word count field,  
ranging from 1 to 32 words. Thirty-two data words is  
represented when the word count field equals 0x00.  
If illegal command detection is not used, all  
Illegalization Table entries should be logic 0, including the  
22 entries for these undefined commands. (The  
Illegalization Table is fully described later in this data sheet.  
After MR reset, all entries equal logic 0.) The terminal  
responds “in form”, transmitting clear status (and a single  
mode data word if the command is MC17, MC20 or MC21  
with T/R bit = 1). Terminal status is updated.  
When the command’s 5-bit subaddress field equals 0 or 31  
(0x1F) a “mode code” command is indicated; the low order  
five bits no longer specify a word count, instead they  
convey a mode code value. This data sheet refers to mode  
code commands by the mode code number. For example,  
a mode command with 5-bit mode code field of 0x10 is  
called MC16, and the full range of mode code values is  
MC0 through MC31 (decimal).  
If illegal command detection applies, the Illegalization  
Table entries for these 22 undefined commands should be  
initialized to logic 1. In this case, the terminal will respond  
with status word only, with Message Error bit set. No mode  
data word is transmitted. Terminal status is updated.  
Mode codes MC16 through MC31 (0x10 through 0x1F)  
have a single associated data word. When the command  
T/R bit equals 0, the data word is contiguous with the  
command word and received by the RT. When the  
command’s T/R bit equals 1, the data word is transmitted  
by the RT, following the terminal’s transmitted status word.  
Twenty-seven mode codes are considered “reserved” in  
MIL-STD-1553B:  
Mode Codes 9 through 15 with T/R bit = 1  
Mode Codes 22 through 31 with T/R bit = 1  
Mode Codes 22 through 31 with T/R bit = 0  
Mode codes MC0 through MC15 (0x0F) do not have  
associated data words. For these 16 commands, the  
command T/R bit does not specify “direction”. These  
commands must be transmitted with T/R bit equal to 1. If  
the T/R bit is 0, the mode command is “undefined”.  
Treatment of these reserved mode commands depends on  
their respective Illegalization Table entries. As described  
above for undefined mode commands, response depends  
on whether or not illegal command detection applies.  
Any mode commands not implemented in the HI-6120  
terminal should be treated the same as reserved mode  
Twenty-two mode commands are “undefined mode  
HOLT INTEGRATED CIRCUITS  
27  
HI-6120, HI-6121  
COMMAND RESPONSES, Cont.  
commands. For example, command MC0 (with T/R = 1) is  
probably unimplemented because the HI-6120 does not  
have provisions for accepting “dynamic bus control”.  
Each mode command with mode data word has its own  
fixed address for data storage. This includes reserved  
mode codes with data word. Thus the HI-6120 can  
respond consistently for all mode commands; transmitted  
data values for “in form” responses (when “illegal  
command detection” is not used) can be predetermined,  
even for the reserved mode commands.  
The important point is that “illegal command detection”  
should be universally applied (or not applied) when setting  
up a HI-6120 Remote Terminal application. Here are the  
two options:  
RT to RT Commands. The MIL-STD-1553 standard  
allows for data word transmission from a specified  
transmitting terminal to a different receiving terminal.  
When broadcast commands are allowed, data  
transmission can be addressed to the broadcast terminal  
address, RT31. If broadcast is allowed, the host should  
initialize the BCSTINV (broadcast invalid) bit in  
Configuration Register 1 to logic 0.  
Not using Illegal command detection. The HI-6120  
Illegalization Table is left in its default state (all locations  
equal to MR post-reset 0x0000). The terminal responds “in  
form” to all valid commands, whether legal or illegal.  
Using illegal command detection. The HI-6120  
Illegalization Table is initialized by the host to implement  
“illegal command detection”. The host sets bits for all illegal  
commands. This generally includes the reserved and  
unimplemented mode commands, unimplemented  
subaddresses (or specific word counts, T/R bit states,  
and/or broadcast vs. non-broadcast status within  
subaddresses). Treatment for the undefined mode  
commands depends on UMCINV bit.  
All RT to RT commands are characterized by a pair of  
contiguous command words: Command Word 1 is a  
receive command addressed to the intended receiving  
terminal, then Command Word 2 is a transmit command  
addressed to a single transmitting terminal. Command  
Word 2 cannot be broadcast address RT31. The HI-6120  
automatically detects and handles RT to RT commands,  
except when either command word contains a subaddress  
field equal to 0x0 or 0x1F. Either subaddress value  
indicates a mode code command; the device treats RT to  
RT commands with mode code as invalid. If either RT-RT  
command word is addressed to the HI-6120 terminal but  
contains subaddress 0x0 or 0x1F, the command is not  
recognized; there is no RT command response, and no  
status updating for the benefit of following “transmit status”  
or “transmit last command” mode commands.  
The host defines terminal response for all individual  
commands by initializing the Descriptor Table, fully  
described later. At this point, a few comments about the  
DescriptorTable are appropriate.  
The command SA(subaddress) field has a range of 0 to 31  
(0x1F). When SA is in the range 1 to 30 (0x1E), the  
command is a transmit or receive “subaddress command”.  
The number of data words transmitted or received is  
expressed in the low order 5 bits. When SA equals 0 or 31  
(0x1F) the command is a mode command and the mode  
code value is expressed in the low order 5 bits.  
When either RT-RT command word (with subaddress field  
not equal to 0x0 or 0x1F) is addressed to the HI-6120  
terminal, but the other command word contains  
subaddress 0x0 or 0x1F, the RT-RT command is not  
recognized as valid. There is no RT command response,  
and no status updating for the benefit of following “transmit  
status” or “transmit last command” mode commands.  
For each subaddress, separate table “descriptor blocks”  
for transmit and receive commands permit different data  
buffering to be applied. The host initializes the table so  
each transmit-subaddress and each receive-subaddress  
uses one of four methods for storing message data. During  
table initialization, memory is allocated in shared RAM for  
storing message data according to the application  
requirements. Each transmit-subaddress and receive-  
subaddress has one or more data pointers (depending on  
buffer method) addressing its reserved data buffer(s).  
An RT-RT command pair where Command Word 1 is  
addressed to the HI-6120 terminal and Command Word 2  
is addressed to a different terminal is considered an “RT-  
RT receive” command. When the message is transacted,  
the device sets the RTRT bit in the Receive Subaddress  
Message Information Word in the subaddress data buffer.  
Each mode command also has its own table “descriptor  
block”. Mode commands have either one data word or no  
associated data words. Descriptor words used as data  
pointers by “subaddress commands” are instead used for  
direct storage of transacted mode data words. Mode  
commands that transmit or receive mode data words have  
a dedicated storage address range in shared RAM,  
eliminating the need for descriptor table data pointers.  
An RT-RT command pair where Command Word 2 is  
solely addressed to the HI-6120 terminal (not RT31) is  
considered an “RT-RT transmit” command. The Message  
Information Word does not distinguish the RT to RT  
transmit message from an ordinary RT to BC transmit  
command.  
HOLT INTEGRATED CIRCUITS  
28  
HI-6120, HI-6121  
COMMAND ILLEGALIZATION TABLE  
The following pages describe various structures residing in  
the RAM shared between the host and HI-6120 or HI-6121  
command processing logic. The host initializes these  
structures to control the terminal’s response to received  
commands. The first structure described is the command  
IllegalizationTable used for “illegal command detection”.  
fetched from the IllegalizationTable:  
If fetched Illegalization Table bit equals logic 0, the  
command is “legal”; the terminal responds “in form”,  
transmitting clear status and transacting the number of  
data words defined for the message type. Terminal status  
is updated.  
Illegal command detection is an optional process. When  
illegal command detection is not used, the terminal  
“responds in form” to all valid commands: it sends Clear  
Status and transacts the number of data words defined in  
the received command. When illegal command detection  
is not used, the bus controller cannot tell whether the  
command is legal or illegal, from the terminal’s transmitted  
response.  
If fetched Illegalization Table bit equals logic 1, the  
command is “illegal”; the terminal responds with status  
word only, with Message Error bit set. No data words are  
transmitted. Terminal status is updated.  
When illegal command detection is not applied, all table  
entries should read logic 0; the terminal responds “in form”  
to all valid commands.  
If illegal command detection is used, the terminal responds  
differently when an illegal command is detected. The  
terminal responds to illegal commands with “message  
error” status, transmitting only status word. Data word  
transmission is suppressed if the command type inherently  
includes transmitted data words. The terminal responds to  
each legal command with clear status and transacts the  
number of data words defined in the type of command  
received.  
The illegalization scheme allows any subset of command  
T/R bit, broadcast vs. non-broadcast status, subaddress  
and word count (or mode code number), for a total of 4,096  
legal/illegal command combinations. Commands may be  
illegalized down to the word count level. For example, 10-  
word receive commands to a given subaddress may be  
legal, while 9-word receive commands to the same  
subaddress are illegal.  
Broadcast receive commands are illegalized separately  
from non-broadcast receive commands. Transmit and  
receive commands for the same subaddress are  
illegalized separately. For mode commands, any  
combination of mode code number, T/R bit and  
broadcast/non-broadcast status can be legal or illegal.  
For consistency, apply illegal command detection to all  
illegal and unimplemented commands, and to all reserved  
or undefined mode code commands, or “respond in form”  
to all of these commands (illegal command detection  
disabled) by leaving the Illegalization Table in the all-  
cleared default state after MR master reset  
The Illegalization Table is located in shared RAM within the  
fixed address range of 0x0100 to 0x01FF. See Figure 4.  
The table is comprised of 256 16-bit words. To cover the  
full range of 1 to 32 data words, each subaddress uses a  
pair of illegalization registers. The lower register (even  
memory address) covers word counts 0 to 15, using one bit  
per word count. As in command encoding, “0” denotes 32  
data words. Bit 0 corresponds to 32 data words, bit 1  
corresponds to 1 data word and bit 15 corresponds to 15  
data words. The upper register (odd memory address)  
similarly covers word counts 16 to 31, using one bit per  
word count. Bit 0 corresponds to 16 data words, while bit  
15 corresponds to 31 data words.  
The device uses a 256-word “Illegalization Table” in shared  
RAM to distinguish between legal and illegal commands.  
After the (MR) master reset input is negated, HI-6120  
performs internal self test including a shared RAM test  
which leaves all memory locations fully reset. Once self  
test is complete, the HI-6120 READY output goes high to  
indicate HI-6120 readiness for host initialization. At this  
point, all entries in the Illegalization Table read logic 0, so  
by default, illegal command detection is not applied.  
To apply illegal command detection, the host (or auto-  
initialization) writes the Illegalization Table to set bits for all  
illegal command combinations. This typically includes any  
unimplemented subaddresses and/or word counts,  
undefined mode commands, reserved mode commands  
and any mode commands not implemented in the terminal  
design. Host initialization of the table can be replaced by  
auto-initialization.  
When a command’s subaddress field equals 0 or 31  
(0x1F), the command is a mode command. Table entries  
for mode commands use bits to represent mode code  
numbers, not word counts. The lower register (even  
memory address) covers mode codes 0 to 15, using one bit  
per mode code. Bit 0 corresponds to mode code 0, bit 15  
corresponds to mode code 15. The upper register (odd  
memory address) similarly covers mode codes 16 to 31,  
using one bit per mode code. Bit 0 corresponds to mode  
code 16, bit 15 corresponds to mode code 31. There is no  
functional difference between SA0 mode commands and  
Once STEX is set in Configuration Register 1, terminal  
execution begins. Each time a valid command is received,  
a 1-bit entry (indexed using command word data bits) is  
HOLT INTEGRATED CIRCUITS  
29  
HI-6120, HI-6121  
COMMAND ILLEGALIZATION TABLE, Cont.  
SA31 mode commands. Since either subaddress  
indicates a mode command, the subaddress 0 table words  
should match the subaddress 31 table words in each  
quadrant.  
block. The word stored at 0x01C3 controls subaddress 1  
transmit commands having word counts 16 to 31. The  
word stored at 0x01C2 controls subaddress 1 transmit  
commands having word counts 1 to 15 or 32. (Reminder:  
In MIL-STD-1553B, zero corresponds to 32 words.)  
Table entries from 0x0142 to 0x017D do not have to be  
programmed. These correspond to broadcast transmit  
subaddress commands (undefined by MIL-STD-1553B)  
and are always invalid. There is no terminal response.  
Word at 0x01C3 (subaddress 1: 31 to 16 words)  
Bit  
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0  
Words 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16  
Word at 0x01C2 (subaddress 1: 15 to 1 & 32 words)  
Addressing for the Illegalization Table is derived from the  
command word T/R bit, subaddress field, MSB of the Word  
Count (Mode Code) field and the command’s broadcast  
vs. non-broadcast status as shown below in Figure 3:  
Bit  
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0  
Words 15 14 13 12 11 10  
9
8 7 6 5 4 3 2 1 32  
If the word stored at 0x01C3 = 0xFFFF and the word stored  
at 0x01C2 = FF0F, then commands with 4, 5, 6, or 7 data  
words are the only legal transmit commands for  
subaddress 1 and all other word counts are illegal. Receive  
commands and broadcast receive commands for  
Subaddresses1 through 30 are encoded similarly.  
Bit Fields Comprise Each Received Command Word  
Terminal  
Address  
Word Count  
Subaddress (Mode Code)  
Command  
Sync  
T/R  
Bit  
TA4:0  
SA4:0  
WC4:0  
P
For “mode code commands” (characterized by  
command word subaddress field equal to 00000 or 11111  
binary) individual table bits correspond to individual mode  
code values. Here “transmit” and “receive” simply indicate  
the state of the command word T/R bit. (For mode codes  
0-15, the T/R bit does not indicate data direction since  
data is not transacted when fulfilling these commands.)  
“0” if  
TA4:0 = 11111  
else “1”  
Table  
Address  
0 0 0 0 0 0 0 1  
Figure 5 summarizes the 16 Illegalization Table locations  
for mode commands. These locations are scattered  
throughout the overall Illegalization Table shown in Figure  
4. Remember: the host must initialize all table locations  
corresponding to both subaddress 0 and subaddress 31  
(11111 binary).  
FIGURE 3. Deriving the Illegalization Table Address  
From the Received Command Word  
Figure 5 shows individual bit locations in the Illegalization  
Table for broadcast and non-broadcast variants of all mode  
commands defined by MIL-STD-1553B. Locations are  
also identifed for reserved mode codes and undefined  
mode code commands.  
Consider an example in which all reserved and all  
undefined mode commands are illegal. If all defined  
transmit mode commands are legal except MC0 (”dynamic  
bus control”) the eight table entries for transmit mode  
commands would be:  
The following examples illustrate how the Illegalization  
Table is initialized to distinguish between legal and illegal  
commands when “illegal command detection” is being  
used. Remember: If the terminal does not use illegal  
command detection, the table is left in its post-MR reset  
state, with all table locations reset to 0x0000. In this case,  
all command responses are “in form”.  
0x01FF and 0x01C1 = 1111 1111 1111 0010 = 0xFFF2  
0x01FE and 0x01C0 = 1111 1110 0000 0001 = 0xFE01  
0x017F and 0x0141 = 1111 1111 1111 1111 = 0xFFFF  
0x017E and 0x0140 = 1111 1110 0000 0101 = 0xFE05  
The receive mode command words are encoded similarly.  
Continuing the same example where all reserved and all  
undefined mode commands are illegal: If all defined  
receive mode commands are legal, the eight table entries  
for receive mode commands would be:  
For “subaddress commands” (ordinary receive  
commands or transmit commands) individual table bits  
correspond to word counts specified in the received  
command word. If a bit is 0, the corresponding word count  
is legal. If a bit is 1, the corresponding word count is illegal.  
0x01BF and 0x0181 = 1111 1111 1100 1101 = 0xFFCD  
0x01BE and 0x0180 = 1111 1111 1111 1111 = 0xFFFF  
0x013F and 0x0101 = 1111 1111 1100 1101 = 0xFFCD  
0x013E and 0x0100 = 1111 1111 1111 1111 = 0xFFFF  
For example, transmit commands to subaddress 1 are  
controlled by the words at 0x01C2 and 0x01C3. In Figure  
4, these words are located in the “RT Address Transmit”  
HOLT INTEGRATED CIRCUITS  
30  
HI-6120, HI-6121  
COMMAND ILLEGALIZATION TABLE, Cont.  
0x01FF  
Tx Subaddress 31 Block (mode codes)  
RT Address Tx Mode Codes 31 - 16  
RT Address Tx Mode Codes 15 - 0  
0x01FF  
0x01FE  
Tx Subaddress 30 Block  
RT Addr Tx SA30 Word Counts 31 - 16  
RT Addr Tx SA30 Word Counts 15 - 0 *  
0x01FD  
0x01FC  
RT Address Transmit Quadrant  
32 subaddress blocks  
of 2 words each.  
* Word Count = 0  
denotes 32 words  
Tx Subaddress 1 Block  
RT Address Tx Mode Codes 31 - 16  
0x01C1  
0x01C0  
Tx Subaddress 0 Block (mode codes)  
RT Address Tx Mode Codes 15 - 0  
0x01C0  
0x01BF  
Rx Subaddress 31 Block (mode codes)  
Rx Subaddress 30 Block  
RT Address Rx Mode Codes 31 - 16  
RT Address Rx Mode Codes 15 - 0  
0x01BF  
0x01BE  
RT Addr Rx SA30 Word Counts 31 - 16  
RT Addr Rx SA30 Word Counts 15 - 0 *  
0x01BD  
0x01BC  
RT Address Receive Quadrant  
32 subaddress blocks  
of 2 words each.  
* Word Count = 0  
denotes 32 words  
Rx Subaddress 1 Block  
RT Address Rx Mode Codes 31 - 16  
0x0181  
0x0180  
Rx Subaddress 0 Block (mode codes)  
RT Address Rx Mode Codes 15 - 0  
0x0180  
0x017F  
Tx Subaddress 31 Block (mode codes)  
Tx Subaddress 30 Block  
Broadcast Tx Mode Codes 31 - 16  
Broadcast Tx Mode Codes 15 - 0  
0x017F  
0x017E  
Broadcast Tx SA30 Word Counts 31 - 16  
Broadcast Tx SA30 Word Counts 15 - 0 *  
0x017D  
0x017C  
Broadcast Transmit Quadrant  
32 subaddress blocks  
of 2 words each.  
SA1 to SA30 are illegal  
broadcast transmit!  
* Word Count = 0  
denotes 32 words  
Tx Subaddress 1 Block  
Broadcast Tx Mode Codes 31 - 16  
0x0141  
0x0140  
Tx Subaddress 0 Block (mode codes)  
Broadcast Tx Mode Codes 15 - 0  
0x0140  
0x013F  
Rx Subaddress 31 Block (mode codes)  
Rx Subaddress 30 Block  
Broadcast Rx Mode Codes 31 - 16  
Broadcast Rx Mode Codes 15 - 0  
0x013F  
0x013E  
Broadcast Rx SA30 Word Counts 31 - 16  
Broadcast Rx SA30 Word Counts 15 - 0 *  
0x013D  
0x013C  
Broadcast Receive Quadrant  
32 subaddress blocks  
of 2 words each.  
* Word Count = 0  
denotes 32 words  
Rx Subaddress 1 Block  
Broadcast Rx Mode Codes 31 - 16  
0x0101  
0x0100  
Rx Subaddress 0 Block (mode codes)  
Broadcast Rx Mode Codes 15 - 0  
0x0100  
Illegalization Table Comprised of  
32 2-Word Blocks per Quadrant  
Example Subaddress Blocks  
from Each Table Quadrant  
FIGURE 4. Fixed Address Mapping for Illegalization Table  
HOLT INTEGRATED CIRCUITS  
31  
HI-6120, HI-6121  
COMMAND ILLEGALIZATION TABLE, Cont.  
Bit No. 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
Transmit  
Mode Commands  
With Data  
0x01FF  
and  
0x01C1  
MC # 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16  
U
Tx MC31 - MC16  
Tx MC15 - MC0  
Status  
R
R
R
R
R
R
R
R
R
R
U
D
D
U
D
Transmit  
Mode Commands  
Without Data  
0x01FE  
and  
0x01C0  
MC # 15 14 13 12 11 10  
R
9
R
8
D
7
D
6
D
5
D
4
D
3
D
2
D
1
D
0
D
Status  
R
R
R
R
R
Receive  
Mode Commands  
With Data  
0x01BF  
and  
0x0181  
MC # 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16  
D
Rx MC31 - MC16  
Rx MC15 - MC0  
Status  
R
R
R
R
R
R
R
R
R
R
D
U
U
D
U
Receive  
Mode Commands  
Without Data  
0x01BE  
and  
0x0180  
MC # 15 14 13 12 11 10  
U
9
U
8
U
7
U
6
U
5
U
4
U
3
U
2
U
1
U
0
U
Status  
U
U
U
U
U
Broadcast Transmit  
Mode Commands  
With Data  
0x017F  
and  
0x0141  
MC # 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16  
R
Br.Tx MC31 - MC16  
Br.Tx MC15 - MC0  
Br.Rx MC31 - MC16  
Br.Rx MC15 - MC0  
Status  
R
R
R
R
R
R
R
R
R
U
U NB NB U NB  
Broadcast Transmit  
Mode Commands  
Without Data  
0x017E  
and  
0x0140  
MC # 15 14 13 12 11 10  
Status  
9
R
8
D
7
D
6
D
5
D
4
D
3
D NB D NB  
2
1
0
R
R
R
R
R
R
Broadcast Receive  
Mode Commands  
With Data  
0x013F  
and  
0x0101  
MC # 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16  
D
Status  
R
R
R
R
R
R
R
R
R
R
D
U
U
D
U
Broadcast Receive  
Mode Commands  
Without Data  
0x013E  
and  
0x0100  
MC # 15 14 13 12 11 10  
U
9
U
8
U
7
U
6
U
5
U
4
U
3
U
2
U
1
U
0
U
Status  
U
U
U
U
U
RAM  
LEGEND  
D = Defined Mode Command  
Address  
R = Reserved Mode Code  
U = Undefined Mode Command NB = Defined Code, But  
Broadcast Not Allowed  
FIGURE 5. Summary of Illegalization Table Addresses for Mode Code Commands  
TEMPORARY RECEIVE DATA BUFFER  
The 32-word temporary receive data buffer resides in  
shared RAM in address space 0x0020 to 0x003F. The  
device optionally uses this buffer for temporary storage of  
receive data words until successful message completion.  
To enable the buffer, the host asserts the TRXDC bit in  
Configuration Register 2.  
20us intervals, the terminal writes received data words to  
assigned subaddress data buffer memory as each word is  
received. If message error occurs during data reception,  
data integrity is lost; valid data from the prior receive  
message may be partially overwritten by data from a  
message ending in error. MIL-STD-1553 states that all  
received data from messages ending in error should be  
disregarded.  
When enabled, the terminal stores received data words in  
the 32-word buffer during message processing. Upon  
error-free message completion, all buffered words are  
written in a burst to the data buffer memory assigned to the  
specific subaddress in the DescriptorTable.  
In a typical application, the temporary buffer is not directly  
accessed by the host, although there is no restriction  
preventing host data access. The host should never write  
data into the temporary buffer space.  
When the TRXDB bit in Configuration Register 2 is  
negated, the temporary receive data buffer is disabled. At  
HOLT INTEGRATED CIRCUITS  
32  
HI-6120, HI-6121  
INTERRUPT LOG BUFFER  
Two interrupt output pins notify the host upon occurrence  
of pre-determined interrupt-causing events. The interrupt  
types are listed below. Each interrupt type only occurs  
when the corresponding interrupt type bit is asserted in the  
Interrupt Enable Register. To manage host interrupts, the  
device architecture uses an Interrupt Log buffer, three  
control registers, two interrupt output pins and two interrupt  
acknowledge input pins. The data sheet section entitled  
“Interrupt Management” provides additional details.  
More than one bit may be asserted in an Interrupt  
Identification Word. For example, IBR (interrupt broadcast  
received) and MERR (interrupt message error) can occur  
for the same message. One assertion of the INTMES  
output pin alerts the host when concurrent message  
interrupts occur.  
The InterruptAddress Word (IAW) identifies the originating  
command for message-based interrupts. When interrupts  
originate from message processing, the Interrupt Address  
Word (IAW) identifies the interrupt source using the 16-bit  
address of the command’s Control Word in the Descriptor  
Table. Hardware interrupts are not linked with command  
processing. These interrupts write an Interrupt Address  
Word value of 0x0000.  
Shown in Figure 8, the Interrupt Log Buffer is a 32-word  
ring buffer located in shared RAM, at address range  
0x0040 to 0x005F. To help the host process interrupts, the  
device interrupt manager maintains information from the  
16 most recent interrupts in this buffer. The buffer contains  
two information words for each occurring interrupt: the  
Interrupt Identification Word and InterruptAddress Word.  
After MR reset or SRST software reset, the device  
automatically initializes bits 7:0 in the Interrupt Log  
Address register to the buffer’s base address, 0x0040. The  
bit 7:0 value read will always be even, ranging from 0x0040  
to 0x005E. Once terminal operation begins, the current  
value of the Interrupt Log Address indicates where the  
Interrupt Information Word (IIW) for the next occurring  
interrupt will be stored.  
The Interrupt Identification Word (IIW) identifies the  
occurring interrupt type using a word format identical to the  
Pending Interrupt Register. Upon update, all bits except  
the occurring interrupt type bit(s) are reset:  
IIW - Interrupt Information Word  
IAW - Interrupt  
Address Word  
On the first interrupt occurring after reset, the device writes  
the IIW and IAW to offset locations 00000 and 00001  
respectively. The device increments the ring buffer pointer  
after each word is stored, storing interrupt information  
sequentially in the ring buffer. Information words for the  
sixteenth interrupt are stored in offset locations 0x1E and  
0x1F (buffer addresses 0x005E and 0x005F) and the  
Interrupt Log Address “rolls over” to again point to offset  
location 0 (buffer address 0x0040) where the Interrupt  
Information Word for the seventeenth interrupt will be  
stored.  
Bit  
15  
14  
13  
12  
11  
10  
9
Interrupt  
IXEQZ  
IWA  
IBRD  
——  
——  
MERR  
——  
ILCMD  
Origin  
Message  
Message  
Message  
——  
IAW contains the  
Command Word  
DescriptorTable  
Address  
——  
Message  
——  
Message  
8
————————————————————  
7
6
5
4
3
2
1
0
SPIFAIL  
LBFA  
LBFB  
TTINT1  
TTINT0  
RTAPF  
EECKF  
RAMIF  
Hardware  
Hardware  
Hardware  
Hardware  
Hardware  
Hardware  
Hardware  
Hardware  
Bits 15:8 in the Interrupt Log Address register maintain a  
count of interrupt events since the register was last read.  
The interrupt count stops at 255 decimal. Counts greater  
than 16 indicate buffer overrun, but the extended count  
capacity is provided as a diagnostic aid.  
IAW contains  
0x0000  
HOLT INTEGRATED CIRCUITS  
33  
HI-6120, HI-6121  
INTERRUPT LOG BUFFER, Cont.  
INTERRUPT 16  
Interrupt Address Word  
0x005F  
0x005E  
0x005D  
0x005C  
0x005B  
0x005A  
0x0059  
0x0058  
0x0057  
0x0056  
0x0055  
0x0054  
0x0053  
0x0052  
0x0051  
0x0050  
0x004F  
0x004E  
0x004D  
0x004C  
0x004B  
0x004A  
0x0049  
0x0048  
0x0047  
0x0046  
0x0045  
0x0044  
0x0043  
0x0042  
0x0041  
0x0040  
The Interrupt Log Address Register  
points to this address after Interrupt  
15 event occurs. Upon Interrupt 16  
completion, device logic reinitializes  
the log address pointer to 0x0040  
before Interrupt 17 is processed.  
INTERRUPT 16  
Interrupt Information Word  
Interrupt Address Word  
INTERRUPT 15  
INTERRUPT 15  
INTERRUPT 14  
INTERRUPT 14  
INTERRUPT 13  
INTERRUPT 13  
Interrupt Information Word  
Interrupt Address Word  
Interrupt Information Word  
Interrupt Address Word  
Interrupt Information Word  
Interrupt Address Word  
Interrupt Information Word  
Interrupt Address Word  
INTERRUPT 12  
INTERRUPT 12  
INTERRUPT 11  
INTERRUPT 11  
INTERRUPT 10  
INTERRUPT 10  
INTERRUPT 9  
EXAMPLE: 2-WORD LOG BUFFER ENTRIES  
FOR VARIOUS INTERRUPT TYPES...  
Interrupt Information Word  
Interrupt Address Word  
Example 1: MERR bit is set in Interrupt Enable Register.  
An error occurs while transacting a receive command for  
subaddress 30:  
Interrupt Information Word  
Interrupt Address Word  
Address Word = 0x0278 Descriptor Address for Rx Subaddress 30.*  
Information Word = 0x0400 MERR (interrupt message error) bit = 1.  
INTERRUPT 9  
INTERRUPT 8  
Interrupt Information Word  
Interrupt Address Word  
Example 2: IWA bit is set in Interrupt Enable Register.  
The IWA bit is set in Transmit Subaddress 30 Control Word  
to generate an interrupt upon each message occurrence.  
A transmit command is received for subaddress 30:  
INTERRUPT 8  
Interrupt Information Word  
Interrupt Address Word  
INTERRUPT 7  
INTERRUPT 7  
INTERRUPT 6  
INTERRUPT 6  
INTERRUPT 5  
INTERRUPT 5  
Address Word = 0x02F8 Descriptor Address for Tx Subaddress 30.*  
Information Word = 0x4000 IWA (interrupt when accessed) bit = 1.  
Interrupt Information Word  
Interrupt Address Word  
Example 3: ILCMD bit is set in Interrupt Enable Register.  
“Illegal Command Detection” is being applied and all  
Illegalization Table bits for undefined mode codes are set.  
An undefined Mode Code 0 with T/R bit = 0 is received:  
Interrupt Information Word  
Interrupt Address Word  
Address Word = 0x0300 Descriptor Address for Rx Mode Code 0.*  
Information Word = 0x0100 ILCMD (interrupt illegal command) bit = 1.  
Interrupt Information Word  
Interrupt Address Word  
Interrupt Information Word  
Interrupt Address Word  
INTERRUPT 4  
INTERRUPT 4  
Example 4: TTINT0 bit is set in Interrupt Enable Register.  
The Time-Tag counter rolls over from full count 0xFFFF  
to 0x0000:  
Address Word = 0x0000 (all hardware interrupts reset the IAW)  
Information Word = 0x0010 TTINT0 (Time-Tag interrupt 0) bit = 1  
INTERRUPT 3  
INTERRUPT 3  
INTERRUPT 2  
INTERRUPT 2  
INTERRUPT 1  
INTERRUPT 1  
Interrupt Information Word  
Interrupt Address Word  
* Figure 9 shows where  
these addresses occur  
in the Descriptor Table.  
Interrupt Information Word  
Interrupt Address Word  
Interrupt Log Address Register  
is initialized by device logic to  
point to this address after  
Interrupt Information Word  
hardware reset (MR) or software reset  
FIGURE 8. Fixed Address Mapping for Interrupt Log Buffer  
HOLT INTEGRATED CIRCUITS  
34  
HI-6120, HI-6121  
DESCRIPTOR TABLE  
The Descriptor Table, resides in shared RAM, in address  
range 0x0200 to 0x03FF. This table is initialized by the host  
(or auto-initialization) to define how the terminal processes  
valid commands. Descriptor Table settings for each  
command specify where message data is stored, how data  
is stored, whether host interrupts are generated, and other  
aspects essential to command processing. Shown in  
Figure 9, the table consists of 128 consecutive “descriptor  
blocks”, each comprised of four 16-bit words. The table is  
organized into four quadrants.  
Each Control Word specifies the data buffer method and  
host interrupt for a specific subaddress or mode command.  
Each subaddress has both a Receive Subaddress block  
and a Transmit Subaddress block. Receive and transmit  
commands to the same subaddress can be programmed  
to respond differently.  
The function of the three remaining descriptor words (in  
each 4-word block) depends on the data buffer method  
specified in the Control Word. Function of descriptor words  
2 through 4 is explained within later data sheet sections for  
the four available data buffer options, briefly listed here:  
The Receive Subaddress and Transmit Subaddress  
quadrants define response for commands having a  
subaddress field ranging from 1 to 30 (0x1E). These are  
simple N-data word receive or transmit commands, where  
N can range from 1 to 32 words. When the command T/R  
bit equals 0, the receive command quadrant applies. When  
the T/R bit equals 1, the transmit command quadrant  
applies.  
Indexed (or Single Buffer) Method where  
a
predetermined number of messages is transacted using a  
single data buffer in shared RAM. Several host interrupt  
options are offered, including an interrupt generated when  
all N messages are successfully completed.  
Double (or Ping-Pong) Buffer Method where successive  
messages alternate between two data buffers in shared  
RAM. Several host interrupt options are offered.  
Both subaddress quadrants are padded at top and bottom  
with unused Descriptor Blocks for subaddresses 0 and 31  
(0x1F). The word space reserved for SA0 and SA31 aligns  
the table addressing, but values stored in these eight  
locations is not used. Command subaddresses 0 and 31  
indicate mode commands. The response for commands  
containing either SA value is defined in the two mode  
command table quadrants. The Receive Mode Command  
quadrant applies when the command word T/R bit equals  
0, while the Transmit Mode Command quadrants applies  
whenT/R equals 1.  
Circular Buffer Mode 1 where buffer boundaries  
determine when the bulk transfer is complete and  
message information and time-tag words are stored with  
message data in a common buffer. Several host interrupt  
options are offered, including an interrupt generated when  
the allocated data buffer is full.  
Circular Buffer Mode 2 where the number of messages  
transacted defines bulk transfer progress, and message  
data words are stored contiguously in one buffer while  
message information and time-tag words are stored in a  
separate buffer. Several host interrupt options are offered,  
including an interrupt generated when all N messages are  
successfully completed.  
The term “Transmit Mode Command” is a misnomer. All  
defined mode commands with mode code less than 0x0F  
haveT/R bit equal to 1, yet none of these mode commands  
transmits a data word. They transmit only the terminal  
status word, just like receive commands.  
Within the Receive and Transmit Mode Command  
quadrants, block addressing is based on the low order 5  
bits in the command word, containing the mode code  
value. This is fundamentally different from the Subaddress  
quadrants in which block addressing is based on the 5-bit  
subaddress field. Figure 10 shows how to derive Control  
Word address from the received Command Word. The  
Control Word address for the last valid command can also  
be found in the Current Control WordAddress register.  
The 4-word Descriptor Table entry for each command (its  
descriptor block) begins with a Control Word. There are  
four types of descriptor Control Word:  
Receive Subaddress Control Word  
Transmit Subaddress Control Word  
Receive Mode Command Control Word  
Transmit Mode Command Control Word  
The descriptor Control Word is initialized by the host to  
select data buffer method and interrupt options. After a  
command is processed by the HI-6120 terminal, the device  
updates the command’s descriptor Control Word. Update  
will differ based on the chosen data buffer method.  
All 128 4-word Descriptor Blocks start with a Control Word.  
There are four Control Word variants, based on command  
type: receive vs. transmit and mode vs. non-mode  
commands. The four Control Word types are defined  
beginning with the next page.  
The four descriptor Control Word types are explained next.  
All descriptor Control Words are initialized by the host (or  
auto-initialization) to define basic command response.  
HOLT INTEGRATED CIRCUITS  
35  
HI-6120, HI-6121  
DESCRIPTOR TABLE, Cont.  
32 4-Word Blocks per Quadrant  
Descriptor Word 4 for Tx MC30  
Descriptor Word 3 for Tx MC30  
Descriptor Word 2 for Tx MC30  
Control Word for Tx MC30  
0x03FB  
0x03FA  
0x03F9  
0x03F8  
0x03FF  
Mode Code 31 Block  
Mode Code 30 Block  
Transmit Mode Code Quadrant.  
(Mode Codes with T/R Bit = 1)  
32 Descriptor Blocks  
of 4 Words Each  
Mode Code 1 Block  
Mode Code 0 Block  
0x0380  
Descriptor Word 4 for Rx MC30  
Descriptor Word 3 for Rx MC30  
Descriptor Word 2 for Rx MC30  
Control Word for Rx MC30  
0x037B  
0x037A  
0x0379  
0x0378  
0x037F  
Mode Code 31 Block  
Mode Code 30 Block  
Receive Mode Code Quadrant.  
(Mode Codes with T/R Bit = 0)  
32 Descriptor Blocks  
of 4 Words Each  
Example 4-Word Descriptor Blocks  
from Each Table Quadrant  
Mode Code 1 Block  
Mode Code 0 Block  
0x0300  
Descriptor Word 4 for Tx SA30  
Descriptor Word 3 for Tx SA30  
Descriptor Word 2 for Tx SA30  
Control Word for Tx SA30  
0x02FB  
0x02FA  
0x02F9  
0x02F8  
0x02FF  
Subaddress 31 Block  
See Note.  
Subaddress 30 Block  
Transmit Subaddress Quadrant.  
32 Descriptor Blocks  
of 4 Words Each  
Subaddress 1 Block  
Subaddress 0 Block  
0x0280  
See Note.  
See Note.  
Descriptor Word 4 for Rx SA30  
Descriptor Word 3 for Rx SA30  
Descriptor Word 2 for Rx SA30  
Control Word for Rx SA30  
0x027B  
0x027A  
0x0279  
0x0278  
0x027F  
Subaddress 31 Block  
Subaddress 30 Block  
Receive Subaddress Quadrant.  
32 Descriptor Blocks  
of 4 Words Each  
NOTE:  
SA0 and SA31 indicate mode commands, so  
are not valid Receive or Transmit Subaddresses.  
Subaddress 1 Block  
See Note.  
Subaddress 0 Block  
0x0200  
FIGURE 9. Address Mapping for Descriptor Table  
This figure assumes table base address = 0x0200.  
HOLT INTEGRATED CIRCUITS  
36  
HI-6120, HI-6121  
DESCRIPTOR TABLE, Cont.  
Command RT Addr T/R Subaddress Word Count  
Sync Bit SA4:0 WC4:0  
TA4:0  
Command RT Addr T/R Subaddress Mode Code  
Sync Bit SA4:0 MC4:0  
TA4:0  
P
P
Descriptor Address Format  
Depends On  
Command Word’s Subaddress  
0x0  
0x3  
0x0  
0x2  
0 0 0 0 0 0 1 0  
0 0  
0 0 0 0 0 0 1 1  
0 0  
Descriptor Table Address  
for Subaddress Commands  
SA4:0 equals 00001 to 11110  
Descriptor Table Address  
for Mode Code Commands  
SA4:0 equals 00000 or 11111  
FIGURE 10. Deriving a Descriptor Table  
Control Word Address From Command Word  
This figure assumes descriptor table base address = 0x0200.  
RECEIVE SUBADDDRESS CONTROLWORD  
Receive Subaddress Control Words apply when a valid command word T/R bit equals zero (receive) and the subaddress field  
has a value in the range of 1 to 30 (0x1E). The descriptor Control Word defines terminal command response and interrupt  
behavior, and conveys activity status to the host. It is initialized by the host before terminal execution begins. Bits 8-11 cannot  
be written by the host; these bits are updated by the device during terminal execution, that is, when Configuration Register 1  
STEX bit equals 1. The host can write bits 0-2 and 4-7 only when STEX equals zero; bits 3 and 12-15 can be written anytime.  
This register is cleared to 0x0000 by MR master reset. Software reset (SRST) clears just the DBAC, DPB and BCAST bits.  
Following any host read cycle to the Control Word address, the DBAC bit is reset.  
Bit maintained by host  
H
D
OPP  
IXEQZIW IBRD MKBUDSBYACDPB BCASPTPONCIR2ZCNIR32CZNIR22ZCNI1R2SZNT0 PPENCIR2ECNIR1EN  
A
Bit maintained by device  
H
H
H
H
D1  
D
D
D
H
H
H
H
H
H
H
H
Bit set by device, reset by host read cycle  
D1  
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
Bit No.  
Mnemonic Function  
15  
IXEQZ  
Interrupt When Index Equals Zero.  
If the Interrupt Enable Register IXEQZ bit is high, assertion of this bit enables generation of an  
interrupt for (a) subaddresses using indexed buffer mode when the INDX value decrements from 1 to  
0, or (b) subaddresses using a circular buffer mode when the pre-determined number of messages  
has been transacted. If enabled, upon completion of command processing that results in index = 0,  
an IXEQZ interrupt is entered in the Pending Interrupt Register, output pin INTMES is asserted, and  
the interrupt is registered in the Interrupt Log.  
14  
13  
IWA  
Interrupt WhenAccessed.  
If the Interrupt Enable Register IWAbit is high, assertion of this bit enables interrupt generation when  
the subaddress receives any valid receive command. If enabled, upon completion of command  
processing, an IWA interrupt is entered in the Pending Interrupt Register, output pin INTMES is  
asserted, and the interrupt is registered in the Interrupt Log.  
IBRD  
Interrupt Broadcast Received.  
If the Interrupt Enable Register IBRD bit is high, assertion of this bit enables interrupt generation  
when the subaddress receives a valid broadcast command. If enabled, upon completion of message  
processing an IBRD interrupt is entered in the Pending Interrupt Register, output pin INTMES is  
asserted, and the interrupt is registered in the Interrupt Log. This bit has no function if the BCSTINV  
bit is high in Configuration Register 1. In this case, commands to RT address 31 are not recognized  
as valid by the device.  
HOLT INTEGRATED CIRCUITS  
37  
HI-6120, HI-6121  
DESCRIPTOR TABLE, Cont.  
MKBUSY Make Busy.  
12  
The host asserts the MKBUSY bit to respond with Busy status for commands to this receive  
subaddress. This bit is an alternative to globally applying Busy status for all valid commands, enabled  
from the 1553 Status Bits Register. See that register description for additional information. When  
Busy is asserted, received data words are not stored and the DPB bit does not toggle after message  
completion.  
11  
10  
DBAC  
DPB  
Descriptor BlockAccessed.  
Internal device logic asserts the DBAC bit upon completion of message processing. The host may  
poll this bit to detect subaddress activity, instead of using host interrupts. This bit is reset to logic 0 by  
MR master reset, SRSTsoftware reset or a host read cycle to this memory address.  
Data Pointer B.  
This status bit is maintained by the device and only applies in ping-pong buffer mode. This bit  
indicates the buffer to be used for the next occurring receive command to this subaddress. When the  
DPB bit is logic 0, the next message will use Data Pointer A; when DPB is logic 1, the next message  
uses Data Pointer B. In ping-pong buffer mode, the bit is inverted after each error-free message  
completion. The DPB bit is not altered after messages ending in error, after illegal commands or after  
messages when the terminal responds with Busy status. This bit is reset to logic 0 by MR master reset  
or SRST software reset; therefore the first message received after either reset will use Buffer A. This  
bit is “don’t care” for indexed single-buffer mode or either circular buffer mode.  
9
8
BCAST  
Broadcast Command.  
Device logic sets this bit when a valid broadcast receive command is received at this subaddress. If  
IBRD bit 13 and Interrupt Enable Register IBRD bit are both set, the output pin INTMES is asserted.  
This bit has no function if the BCSTINV bit is asserted in the Configuration Register 1; in this case  
commands to RT address 31 are not recognized as valid by the device. This bit is reset to logic 0 by  
MR master reset or SRSTsoftware reset.  
PPON  
Ping-Pong EnableAcknowledge.  
This bit is controlled by the device and cannot be written by the host. It only applies if PPEN bit 2 was  
initialized to logic one by the host after reset, enabling ping-pong buffer mode for this subaddress.  
Device logic asserts this bit when it recognizes ping-pong is active for this subaddress. Before off-  
loading the receive data buffer for this subaddress, the host can ask the device to temporarily disable  
ping-pong by asserting STOPP bit 3. The device acknowledges ping-pong is disabled by negating  
PPON. The host can safely off-load the buffer without data collision while PPON is negated. After  
buffer servicing, the host asks the device to re-enable ping-pong by negating STOPP bit 3. The  
device acknowledges ping-pong is re-enabled by asserting PPON.  
If PPEN bit 2 is high and PPON bit 8 is low when new commands arrive for this subaddress, ping-  
pong is disabled. Each new message overwrites existing data in the buffer specified by DPB bit 10,  
and the DPB bit does not toggle after command completion.  
7-4  
3
CIR2ZN  
STOPP  
Circular Mode 2 Zero Number.  
Used only in circular buffer mode 2, this 4-bit field is initialized with the number of trailing zeros in the  
initialized MIBAaddress. This is explained in a later section that fully describes circular buffer mode 2.  
Stop Ping-Pong Request.  
The host asserts this bit to suspend ping-pong buffering for this subaddress. The host resets this bit to  
ask the device to re-enable ping-pong. The device confirms recognition of ping-pong enable or  
disable status by writing PPON bit 8. Refer to later section fully describing ping-pong mode.  
2
PPEN  
Ping-Pong Buffer Enable.  
The PPEN, CIR1EN and CIR2EN bits are initialized by the host to select buffer mode. For  
explanation, see description below for bits 1-0.  
After reset, the host initializes the PPEN bit to logic one to enable ping-pong buffering for this  
subaddress. The host asserts STOPP bit 3 to ask the device to temporarily disable ping-pong.  
Negating the STOPP bit asks the device to re-enable ping-pong. The device confirms ping-pong  
enable or disable state changes by writing the PPON bit.  
HOLT INTEGRATED CIRCUITS  
38  
HI-6120, HI-6121  
DESCRIPTOR TABLE, Cont.  
1
0
CIR2EN  
CIR1EN  
Circular Buffer Mode 2 Enable.  
Circular Buffer Mode 1 Enable.  
The PPEN, CIR1EN and CIR2EN bits are initialized by the host to select buffer mode. This table  
summarizes how buffer mode selection is encoded:  
PPEN  
CIR2EN  
Don’t care  
CIR1EN  
Don’t care  
Don’t care  
Buffer Mode  
Ping-Pong  
Circular Mode 2  
Circular Mode 1  
Indexed Single Buffer  
1
0
0
0
1
0
0
1
0
TRANSMIT SUBADDRESS CONTROLWORD  
Transmit Subaddress Control Words apply when a valid command word T/R bit equals one (transmit) and the subaddress field  
has a value in the range of 1 to 30 (0x1E). The descriptor Control Word defines terminal command response and interrupt  
behavior, and conveys activity status to the host. It is initialized by the host before terminal execution begins. Bits 8-11 cannot  
be written by the host; these bits are updated by the device during terminal execution, that is, when Configuration Register 1  
STEX bit equals 1. The host can write bits 0-2 and 4-7 only when STEX equals zero; bits 3,12 and 14-15 can be written  
anytime. This register is cleared to 0x0000 by MR master reset. Software reset (SRST) clears just the DBAC, DPB and  
BCASTbits. Following any host read cycle to the Control Word address, the DBAC bit is reset.  
Bit maintained by host  
H
D
OPP  
MKBUDSBYACDPB BCASPTPONCIR2ZCNIR32CZNIR22ZCNI1R2SZNT0 PPENCIR2ECNIR1EN  
A
IXEQZIW  
Bit maintained by device  
H
H
X
H
D1  
D
D
D
H
H
H
H
H
H
H
H
Bit set by device, reset by host read cycle  
Bit is not used, may be logic 0 or 1  
D1  
X
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
Bit No.  
Mnemonic Function  
15  
IXEQZ  
Interrupt When Index Equals Zero.  
If the Interrupt Enable Register IXEQZ bit is high, assertion of this bit enables generation of an  
interrupt for (a) subaddresses using indexed buffer mode when the INDX value decrements from 1 to  
0, or (b) subaddresses using a circular buffer mode when the pre-determined number of messages  
has been transacted. If enabled, upon completion of command processing that results in index = 0,  
an IXEQZ interrupt is entered in the Pending Interrupt Register, output pin INTMES is asserted, and  
the interrupt is registered in the Interrupt Log.  
14  
IWA  
——  
Interrupt WhenAccessed.  
If the Interrupt Enable Register IWAbit is high, assertion of this bit enables interrupt generation when  
the subaddress receives any valid transmit command. If enabled, upon completion of command  
processing, an IWA interrupt is entered in the Pending Interrupt Register, output pin INTMES is  
asserted, and the interrupt is registered in the Interrupt Log.  
13  
12  
Not used.  
MKBUSY Make Busy.  
The host asserts the MKBUSY bit to respond with Busy status for commands to this transmit  
subaddress. This bit is an alternative to globally applying Busy status for all valid commands, enabled  
from the 1553 Status Bits Register. See that register description for additional information. When  
Busy is asserted, data words are not transmitted and the DPB bit does not toggle after message  
completion.  
11  
10  
DBAC  
DPB  
Descriptor BlockAccessed.  
Internal device logic asserts the DBAC bit upon completion of message processing. The host may  
poll this bit to detect subaddress activity, instead of using host interrupts. This bit is reset to logic zero  
by MR master reset, SRSTsoftware reset or a host read cycle to this memory address.  
Data Pointer B.  
This status bit is maintained by the device and only applies in ping-pong buffer mode. This bit  
HOLT INTEGRATED CIRCUITS  
39  
HI-6120, HI-6121  
DESCRIPTOR TABLE, Cont.  
indicates the buffer to be used for the next occurring transmit command to this subaddress. When the  
DPB bit is logic 0, the next message will use Data Pointer A; when DPB is logic 1, the next message  
uses Data Pointer B. In ping-pong buffer mode, the bit is inverted after each error-free message  
completion. The DPB bit is not altered after messages ending in error, after illegal commands or after  
messages when the terminal responds with Busy status. This bit is reset to logic 0 by MR master reset  
or SRST software reset; therefore the first message received after either reset will use Buffer A. This  
bit is “don’t care” for indexed single-buffer mode or either circular buffer mode.  
9
BCAST  
Broadcast Received.  
The device sets this bit when a broadcast-transmit command is received for this subaddress.  
Because non-mode broadcast-transmit commands are always illegal, the assertion of this bit in the  
Control Word by the device indicates an illegal command was received. Terminal response varies,  
depending on whether or not illegal command detection applies (any bits set in Illegalization Table).  
This bit has no function if the BCSTINV bit is asserted in Configuration Register 1; in this case  
commands to RT address 31 are not recognized as valid by the device. This bit is reset to logic 0 by  
MR master reset or SRSTsoftware reset.  
8
PPON  
Ping-Pong EnableAcknowledge.  
This bit is controlled by the device and should not be written by the host. It only applies if PPEN bit 2  
was initialized to logic one by the host after reset, enabling ping-pong buffer mode for this  
subaddress. The RT asserts this bit when it recognizes ping-pong is active for this subaddress.  
Before loading the transmit data buffer for this subaddress, the host can ask the RT to temporarily  
disable ping-pong by asserting STOPP bit 3. The RT acknowledges ping-pong is disabled by  
negating PPON. The host can safely load the buffer without data collision while PPON is negated.  
After buffer servicing, the host asks the RT to re-enable ping-pong by negating STOPP bit 3. The RT  
acknowledges ping-pong is re-enabled by asserting PPON.  
If PPEN bit 2 is high and PPON bit 8 is low when new commands arrive for this subaddress, ping-  
pong is disabled. Each new message transmits data from the same buffer, specified by DPB bit 10,  
and the DPB bit does not toggle after command completion.  
7-4  
3
CIR2ZN  
STOPP  
Circular Mode 2 Zero Number.  
Used only in circular buffer mode 2, this 4-bit field is initialized with the number of trailing zeros in the  
initialized MIBAaddress. This is explained in a later section fully describing circular buffer mode 2.  
Stop Ping-Pong Request.  
The host asserts this bit to suspend ping-pong buffering for this subaddress. The host resets this bit to  
ask the RT to re-enable ping-pong. The RT confirms recognition of ping-pong enable or disable  
status by writing PPON bit 8. Refer to later section describing ping-pong mode for more information.  
2
PPEN  
Ping-Pong Buffer Enable.  
The PPEN, CIR1EN and CIR2EN bits are initialized by the host to select buffer mode. For  
explanation, see description below for bits 1-0.  
After reset, the host initializes this bit to logic one to enable ping-pong buffering for this subaddress.  
The host asserts STOPP bit 2 to ask the device to temporarily disable ping-pong. Negating the  
STOPP bit asks the device to re-enable ping-pong. The device confirms ping-pong enable or disable  
state changes by writing the PPON bit.  
1
0
CIR2EN  
CIR1EN  
Circular Buffer Mode 2 Enable.  
Circular Buffer Mode 1 Enable.  
The PPEN, CIR1EN and CIR2EN bits are initialized by the host to select buffer mode. This table  
summarizes how buffer mode selection is encoded:  
PPEN  
CIR2EN  
Don’t care  
CIR1EN  
Don’t care  
Don’t care  
Buffer Mode  
Ping-Pong  
Circular Mode 2  
Circular Mode 1  
Indexed Single Buffer  
1
0
0
0
1
0
0
1
0
HOLT INTEGRATED CIRCUITS  
40  
HI-6120, HI-6121  
DESCRIPTOR TABLE, Cont.  
DIFFERENT DATABUFFER OPTIONS FOR MODE CODE COMMANDS  
Data buffer options for mode code commands differ from options offered for subaddress commands. Mode commands cannot  
use either circular data buffer method, but may use double (ping-pong) buffering or single (indexed) buffering.Single message  
Index mode (INDX = 0) is suitable in many applications. An alternative called Simplified Mode Command Processing  
(SMCP) may be globally applied for all mode code commands.  
To use single (indexed) buffer or double (ping-pong) buffer for mode commands, the SMCP bit in Configuration Register 1 is  
logic 0. The Control Word PPEN bit for each mode command determines whether ping-pong or indexed buffering is used.  
To use Simplified Mode Command Processing, the SMCP bit in Configuration Register 1 is set to logic 1. The Control Word  
PPEN bit for mode commands is “don’t care” (no longer specifies index or ping-pong buffer mode) because Simplified Mode  
Command Processing stores mode command data and message information words directly within each mode command’s  
redefined Descriptor Table block. When SMCP is enabled, mode code command descriptor blocks (in the Descriptor Table) do  
not contain data pointers to reserved buffers elsewhere in the shared RAM. Instead, each 4-word descriptor block itself  
contains the message information word, the time-tag word and the data word transacted for each mode command (for mode  
codes 16-31 decimal).  
When Simplified Mode Command Processing is used, the range of active bits is reduced in each receive or transmit mode  
command Control Word. Interrupt control and response is not affected by the SMCP option. Simplified Mode Command  
Processing is fully presented in the later data sheet section entitled “Mode Code Commands.”  
RECEIVE MODE CONTROLWORD  
Receive Mode Control Words apply when the command word T/R bit equals zero (receive) and the subaddress field has a  
value of 0 or 31 (0x1F). The descriptor Control Word defines terminal command response and interrupt behavior, and conveys  
activity status to the host. It is initialized by the host before terminal execution begins. Bits 8-11 cannot be written by the host;  
these bits are updated by the device during terminal execution, that is, when Configuration Register 1 STEX bit equals 1. The  
host can write bit 2 only when STEX equals zero; bits 3 and 12-15 can be written anytime. This register is cleared to 0x0000 by  
MR master reset. Software reset (SRST) clears just the DBAC, DPB and BCAST bits. Following any host read cycle to the  
Control Word address, the DBAC bit is reset.  
When single-message indexed buffering or ping-pong buffering is used instead of SMCP (Simplified Mode Code Processing),  
the transmit mode Control Word looks like this:  
SMCP Disabled  
Bit maintained by host  
H
D
Bit maintained by device  
OPP  
A
IXEQZIW IBRD MKBU  
D
S
B
Y
ACDPB BCASPTPON  
ST PPEN  
Bit set by device, reset by host read cycle  
Bit is not used, may read logic 0 or 1  
D1  
X
H
H
H
H
D1  
D
D
D
X
X
X
X
H
H
X
X
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
When SMCPapplies, the number of active mode Control Word bits is reduced:  
SMCP Enabled  
Bit maintained by host  
H
Bit maintained by device  
D
A
IXEQZIW IBRD MKBU  
D
S
B
Y
AC  
BCAST  
Bit set by device, reset by host read cycle  
Bit is not used, may read logic 0 or 1  
D1  
X
H
H
H
H
D1  
X
D
X
X
X
X
X
X
X
X
X
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
Bit No.  
Mnemonic Function  
IXEQZ Interrupt When Index Equals Zero.  
15  
If the Interrupt Enable Register IXEQZ bit is high, assertion of this bit enables generation of an  
interrupt for mode code commands using indexed buffer mode when the INDX value decrements  
from 1 to 0. Upon completion of command processing that results in INDX = 0, when IXEQZ interrupts  
HOLT INTEGRATED CIRCUITS  
41  
HI-6120, HI-6121  
DESCRIPTOR TABLE, Cont.  
are enabled, an IXEQZ interrupt is entered in the Pending Interrupt Register, the INTMES output pin  
is asserted, and the interrupt is registered in the Interrupt Log.  
14  
IWA  
Interrupt WhenAccessed.  
If the Interrupt Enable Register IWA bit is high, assertion of this bit enables interrupt generation at  
each instance of a valid mode code command. Upon completion of command processing, when IWA  
interrupts are enabled, an IWA interrupt is entered in the Pending Interrupt Register, the INTMES  
output pin is asserted, and the interrupt is registered in the Interrupt Log.  
13  
IBRD  
Interrupt Broadcast Received.  
If the Interrupt Enable Register IBRD bit is high, assertion of this bit enables interrupt generation at  
each instance of a valid broadcast receive mode code command. Upon completion of command  
processing, when IBRD interrupts are enabled, an IBRD interrupt is entered in the Pending Interrupt  
Register, the INTMES output pin is asserted, and the interrupt is registered in the Interrupt Log. This  
bit has no function if the BCSTINV bit is high in Configuration Register 1. In this case, commands to  
RTaddress 31 are not recognized as valid by the device.  
12  
MKBUSY Make Busy.  
The host asserts the MKBUSY bit to respond with Busy status for commands to this mode code. This  
bit is an alternative to globally applying Busy status for all valid commands, enabled from the 1553  
Status Bits Register. See that register description for additional information. When Busy is asserted,  
mode data words received with MC16-MC31 are not stored and the DPB bit does not toggle after  
message completion.  
11  
10  
DBAC  
DPB  
Descriptor BlockAccessed.  
Internal device logic asserts the DBAC bit upon completion of message processing. The host may  
poll this bit to detect mode command activity, instead of using host interrupts. This bit is reset to logic 0  
by MR master reset, SRSTsoftware reset or a host read cycle to this memory address.  
Data Pointer B.  
This status bit is maintained by the device and only applies for mode commands using ping-pong  
buffer mode. This bit indicates the buffer to be used for the next occurring mode command. When the  
DPB bit is logic 0, the next message will use Data Pointer A; when DPB is logic 1, the next message  
uses Data Pointer B. In ping-pong buffer mode, the bit is inverted after each error-free message  
completion. The DPB bit is not altered after messages ending in error, after illegal commands, or after  
messages when the terminal responds with Busy status. This bit is reset to logic 0 by MR master reset  
or SRST software reset; therefore the first message received after either reset will use Buffer A. This  
bit is “don’t care” for indexed single-buffer mode.  
9
8
BCAST  
PPON  
Broadcast Received.  
Device logic sets this bit when a valid broadcast mode command is received having T/R bit = 0. This  
bit has no function if the BCSTINV bit is asserted in Configuration Register 1. In this case, RT address  
31 commands are not recognized as valid by the HI-6120. This bit is reset to logic 0 by MR master  
reset or SRSTsoftware reset.  
Ping-Pong EnableAcknowledge.  
This bit is read only and only applies for mode commands using ping-pong mode (PPEN bit 2 was  
initialized to logic 1 by the host after reset). The device asserts this bit when it recognizes ping-pong is  
active for this mode code. Before off-loading the receive data buffer for this mode code, the host can  
ask the device to temporarily disable ping-pong by asserting STOPP bit 3. The device acknowledges  
ping-pong is disabled by negating PPON. The host can safely load or off-load the buffer without data  
collision while PPON is negated. After buffer servicing, the host asks the device to re-enable ping-  
pong by negating STOPP bit 3. The device acknowledges ping-pong is re-enabled by asserting  
PPON.  
If PPEN bit 2 is high and PPON bit 8 is low when new commands arrive for this subaddress, ping-  
pong is disabled. Each new message overwrites existing data in the buffer specified by DPB bit 10,  
and the DPB bit does not toggle after command completion.  
7-4  
——  
Not used.  
HOLT INTEGRATED CIRCUITS  
42  
HI-6120, HI-6121  
DESCRIPTOR TABLE, Cont.  
Stop Ping-Pong Request.  
3
STOPP  
The host asserts this bit to suspend ping-pong buffering for this mode code. The host resets this bit to  
ask the device to re-enable ping-pong. The device confirms recognition of ping-pong enable or  
disable status by writing PPON bit 3.  
2
PPEN  
Ping-Pong Buffer Enable.  
The PPEN bit is initialized by the host to select buffer mode. If this bit is high, ping-pong buffering is  
selected. If this bit is low, indexed single buffering is selected.  
After reset, the host initializes this bit to logic 1 to enable ping-pong buffering for this mode code. The  
host asserts STOPP bit 3 to ask the device to temporarily disable ping-pong. Negating the STOPP bit  
asks the device to re-enable ping-pong. The device confirms ping-pong enable or disable state  
changes by writing the PPON bit.  
1-0  
——  
Not used.  
TRANSMIT MODE CONTROLWORD  
Transmit Mode Control Words apply when the command word T/R bit equals one (transmit) and the subaddress field has a  
value of 0 or 31 (0x1F). The descriptor Control Word defines terminal command response and interrupt behavior, and conveys  
activity status to the host. It is initialized by the host before terminal execution begins. Bits 8-11 cannot be written by the host;  
these bits are updated by the device during terminal execution, that is, when Configuration Register 1 STEX bit equals 1. The  
host can write bit 2 only when STEX equals zero; bits 3 and 12-15 can be written anytime. This register is cleared to 0x0000 by  
MR master reset. Software reset (SRST) clears just the DBAC, DPB and BCAST bits. Following any host read cycle to the  
Control Word address, the DBAC bit is reset.  
When single-message indexed buffering or ping-pong buffering is used instead of SMCP (Simplified Mode Code Processing),  
the transmit mode Control Word looks like this:  
SMCP Disabled  
Bit maintained by host  
H
D
Bit maintained by device  
OPP  
A
IXEQZIW IBRD MKBU  
D
S
B
Y
ACDPB BCASPTPON  
ST PPEN  
Bit set by device, reset by host read cycle  
Bit is not used, may read logic 0 or 1  
D1  
X
H
H
H
H
D1  
D
D
D
X
X
X
X
H
H
X
X
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
When SMCPapplies, the number of active mode Control Word bits is reduced:  
SMCP Enabled  
Bit maintained by host  
H
Bit maintained by device  
D
A
IXEQZIW IBRD MKBU  
D
S
B
Y
AC  
BCAST  
Bit set by device, reset by host read cycle  
Bit is not used, may read logic 0 or 1  
D1  
X
H
H
H
H
D1  
X
D
X
X
X
X
X
X
X
X
X
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
Bit No.  
Mnemonic Function  
IXEQZ Interrupt When Index Equals Zero.  
15  
If the Interrupt Enable Register IXEQZ bit is high, assertion of this bit enables generation of an  
interrupt for mode code commands using indexed buffer mode when the INDX value decrements  
from 1 to 0. Upon completion of command processing that results in INDX = 0, when IXEQZ interrupts  
are enabled, an IXEQZ interrupt is entered in the Pending Interrupt Register, the INTMES output pin  
is asserted, and the interrupt is registered in the Interrupt Log.  
14  
IWA  
Interrupt WhenAccessed.  
If the Interrupt Enable Register IWA bit is high, assertion of this bit enables interrupt generation at  
each instance of a valid mode code command. Upon completion of command processing, when IWA  
HOLT INTEGRATED CIRCUITS  
43  
HI-6120, HI-6121  
DESCRIPTOR TABLE, Cont.  
interrupts are enabled, an IWA interrupt is entered in the Pending Interrupt Register, the INTMES  
output pin is asserted, and the interrupt is registered in the Interrupt Log.  
13  
IBRD  
Interrupt Broadcast Received.  
If the Interrupt Enable Register IBRD bit is high, assertion of this bit enables interrupt generation at  
each instance of a valid broadcast transmit mode code command. Upon completion of command  
processing, when IBRD interrupts are enabled, an IBRD interrupt is entered in the Pending Interrupt  
Register, the INTMES output pin is asserted, and the interrupt is registered in the Interrupt Log. This  
bit has no function if the BCSTINV bit is high in Configuration Register 1. In this case, commands to  
RTaddress 31 are not recognized as valid by the device.  
12  
MKBUSY Make Busy.  
The host asserts the MKBUSY bit to respond with Busy status for commands to this mode code. This  
bit is an alternative to globally applying Busy status for all valid commands, enabled from the 1553  
Status Bits Register. See that register description for additional information. When Busy is asserted,  
mode data words are not transmitted with MC16-MC31, and the DPB bit does not toggle after  
message completion. The MKBUSY bit is not heeded if set in the Control Word for mode code  
command MC8 “reset remote terminal”. For this command only, Busy is inhibited for the status  
response transmitted before the reset process begins.  
11  
10  
DBAC  
DPB  
Descriptor BlockAccessed.  
Internal device logic asserts the DBAC bit upon completion of message processing. The host may  
poll this bit to detect mode command activity, instead of using host interrupts. This bit is reset to logic 0  
by MR master reset, SRSTsoftware reset or a host read cycle to this memory address.  
Data Pointer B.  
This status bit is maintained by the device and only applies for mode commands using ping-pong  
buffer mode. This bit indicates the buffer to be used for the next occurring mode command. When the  
DPB bit is logic 0, the next message will use Data Pointer A; when DPB is logic 1, the next message  
uses Data Pointer B. In ping-pong buffer mode, the bit is inverted after each error-free message  
completion. The DPB bit is not altered after messages ending in error, after illegal commands, or after  
messages when the terminal responds with Busy status. This bit is reset to logic 0 by MR master reset  
or SRST software reset; therefore the first message received after either reset will use Buffer A. This  
bit is “don’t care” for indexed single-buffer mode.  
9
8
BCAST  
PPON  
Broadcast Received.  
Device logic sets this bit when a valid broadcast mode command is received having T/R bit = 1. This  
bit has no function if the BCSTINV bit is asserted in Configuration Register 1. In this case, RT address  
31 commands are not recognized as valid by the HI-6120. This bit is reset to logic 0 by MR master  
reset or SRSTsoftware reset.  
Ping-Pong EnableAcknowledge.  
This bit is read only and only applies for mode commands using ping-pong mode (PPEN bit 2 was  
initialized to logic 1 by the host after reset). The device asserts this bit when it recognizes ping-pong is  
active for this mode code. Before loading the transmit data buffer for this mode code, the host can ask  
the device to temporarily disable ping-pong by asserting STOPP bit 3. The device acknowledges  
ping-pong is disabled by negating PPON. The host can safely load or off-load the buffer without data  
collision while PPON is negated. After buffer servicing, the host asks the device to re-enable ping-  
pong by negating STOPP bit 3. The device acknowledges ping-pong is re-enabled by asserting  
PPON.  
If PPEN bit 2 is asserted and PPON bit 8 is negated when a new command arrives for this mode code,  
ping-pong disable handshake is in effect: The device applies single-buffer index mode using Data  
PointerAor Data Pointer B, per DPB bit 10. The DPB bit does not toggle after command completion.  
HOLT INTEGRATED CIRCUITS  
44  
HI-6120, HI-6121  
DESCRIPTOR TABLE, Cont.  
Not used.  
7-4  
——  
3
STOPP  
Stop Ping-Pong Request.  
The host asserts this bit to suspend ping-pong buffering for this mode code. The host resets this bit to  
ask the device to re-enable ping-pong. The device confirms recognition of ping-pong enable or  
disable status by writing PPON bit 3.  
2
PPEN  
Ping-Pong Buffer Enable.  
The PPEN bit is initialized by the host to select buffer mode. If this bit is high, ping-pong buffering is  
selected. If this bit is low, indexed single buffering is selected.  
After reset, the host initializes this bit to logic 1 to enable ping-pong buffering for this mode code. The  
host asserts STOPP bit 3 to ask the device to temporarily disable ping-pong. Negating the STOPP bit  
asks the device to re-enable ping-pong. The device confirms ping-pong enable or disable state  
changes by writing the PPON bit.  
1-0  
——  
Not used.  
MESSAGE DATA BUFFERS  
The memory structures described up to this point comprise  
not more than 1K words of the lower memory address  
space. The remaining memory is allocated by the host for  
message data storage, to fulfill application requirements.  
This section describes the remaining data structures in  
shared RAM that control (and result from) command  
processing.  
shared RAM. For receive commands, the device stores  
data received during message processing in the shared  
RAM buffer. Later, the host retrieves these data words from  
the buffer. In the case of transmit commands, the host has  
previously stored transmit data words in the transmit  
subaddress buffer. The device retrieves these data words  
for transmission while processing the transmit command.  
By initializing the Descriptor Table, the host allocates  
memory space for storing data for each subaddress used  
in the Remote Terminal application. Each legal Receive  
Subaddress and each legal Transmit Subaddress are  
usually assigned unique buffer memory spaces.  
(Exception: To comply with the requirements for MIL-STD-  
1553 data wrap-around, it is convenient to assign the data  
wrap-around subaddress to use the same buffer space for  
both receive and transmit commands.)  
For each complete message processed, the message  
data stored in the buffer is comprised of these elements:  
1. Message Information Word  
2. Time-Tag Word  
3. One to 32 Data Words transmitted or received  
during message transaction ( except no data  
word for mode code commands 0 - 15 decimal)  
The Message Information word and Time-Tag word are  
generated by the device and stored in assigned buffer  
space to aid the host in further message processing. The  
Message Information word contains message type, word  
count and message error information. The 16-bit Time-Tag  
word contains the value in the device internal Time-Tag  
counter when the command is validated.  
As an option, data from broadcast receive commands can  
be stored separately from data resulting from non-  
broadcast receive commands. Each subaddress buffer  
can use any of four data storage methods offered.  
Subaddress (non-mode) commands are transacted with  
one to 32 data words. These are stored in a data buffer in  
HOLT INTEGRATED CIRCUITS  
45  
HI-6120, HI-6121  
MESSAGE DATA BUFFERS  
The host initializes the Descriptor Table entry for each  
subaddress or mode command to select one of four data  
buffering methods. Briefly summarized here, the options  
are explained in full detail in the next section of this data  
sheet:  
Circular Buffer Mode 2.  
The number of messages transacted defines bulk transfer  
progress. Message data words are stored contiguously in  
one buffer while message information and time-tag words  
are stored in a separate buffer. Several host interrupt  
options are offered, including host interrupt when all N  
messages are completed.  
Indexed (Single Buffer) Method.  
A predetermined number of messages (N) is transacted  
using a single data buffer in shared RAM. Several host  
interrupt options are offered, including host interrupt when  
all N messages are successfully completed. This method  
also supports single-message mode when N is purposely  
initialized to zero.  
Simplified Mode Command Processing.  
This is a global option that applies for all mode code  
commands, when enabled. Mode commands have either  
one data word, or no data word. Instead of using data  
buffers for storing this limited mode command data, the  
message data is stored directly within the Descriptor Table.  
This option for mode commands is described in the section  
called “Mode Command Processing.”  
Double (or Ping-Pong) Buffer Method.  
Successive messages alternate between two 34-word  
data buffers in shared RAM. Several host interrupt options  
are offered.  
Circular Buffer Mode 1.  
Buffer boundaries determine when the bulk transfer is  
complete. Message information and time-tag words are  
stored in the same buffer with data words. Several host  
interrupt options are offered, including host interrupt when  
the allocated data buffer is full.  
DATA BUFFER MODES AT A GLANCE  
BUFFER  
MODE  
DATA BUFFER(S)  
NUMBER & SIZE  
MESSAGE  
INFO WORDS  
SUITABLE FOR  
MODE CODES? PRIMARY APPLICATION  
Indexed  
one, host defines  
size for N messages  
stored in same  
buffer as data  
yes, only single  
message mode  
For transacting N (multiple) messages  
with optional host interrupt when done  
Ping-Pong two 34-word buffers,  
1 message each  
stored in same  
buffers as data  
yes  
no  
For transacting single messages,  
alternating between A and B buffers  
Circular 1  
Circular 2  
one, host defines  
size for N words  
stored in same  
buffer as data  
For transacting messages until buffer is  
full / empty, optional interrupt when done  
one, host defines  
size for N messages,  
plus Msg Info Block  
stored in  
separate buffer  
(Msg Info Block)  
no  
For transacting N (multiple) messages  
with optional host interrupt when done.  
Data buffer holds contiguous pure data.  
Broadcast Data Separation  
When the NOTICE2 option is enabled, data words resulting from broadcast receive commands will be stored separately  
from data resulting from non-broadcast receive commands when using indexed or ping-pong buffer modes. When  
NOTICE2 applies, all subaddresses using indexed or ping-pong modes must have an assigned 34-word broadcast data  
buffer in addition to the primary buffers listed above. Broadcast data segregation cannot be done using either circular  
buffer mode.  
HOLT INTEGRATED CIRCUITS  
46  
HI-6120, HI-6121  
MESSAGE DATA BUFFERS, Cont.  
RECEIVE SUBADDRESS COMMAND  
MESSAGE INFORMATION WORD  
For receive subaddress commands, the device stores the received data words plus two additional words. The device adds a  
receive subaddress Message Information Word and a Time-Tag Word to the received data words. The device stores the  
Message Information and Time-Tag words ahead of the data words associated with the receive command, as shown below. If  
message error occurs, the RT stores only the receive subaddress Message Information Word and Time-Tag Word. Once a  
message error is detected, the device sets the MERR bit in the receive subaddress Message Information word. When this  
occurs, all data words are considered invalid. Whenever the receive subaddress Message Information Word MERR bit is set,  
the host should disregard the record’s data word(s).  
Here is an example data structure for a 3-word receive command. Notice that the receive subaddress Data Pointer points to  
the data structure starting address, not the first data word. The data pointer is located in the receive subaddress command’s  
Descriptor Block, fully described later:  
Data Buffer  
HexAddress  
Word Description  
Device Writes Word...  
Data pointer equals 0x0500 ———> 0x0500  
Message Information Word After message completion  
0x0501  
0x0502  
0x0503  
0x0504  
Time-Tag Word  
Data Word 1  
Data Word 2  
Data Word 3  
After message completion (note)  
The data words are written after message  
completion when Configuration Register 2  
TRXDB is 1, otherwise written when received.  
TERR  
RT  
ASBSY  
RRW  
TMOEIWRRDEGRARPEWRRCTE  
S
R
Y
R
NE  
M
R
E
R
ILCMDTXR RT BUSIDWC4 WC3 WC2 WC1 WC0  
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
The following bits comprise the receive subaddress Message Information Word:  
Bit No.  
Mnemonic Function  
15  
TMOERR Time-Out Error.  
This bit is asserted for RT-RT receive messages when the transmitting terminal fails to start its status  
word and data transmission before time-out occurs, perTOSEL0-1 bits in Configuration Register 2.  
14  
13  
IWDERR Invalid Word Error.  
Assertion of this bit indicates Manchester error or parity error was observed in a received data word.  
GAPERR Gap Error.  
Assertion of this bit indicates bus activity was detected immediately after the last expected receive  
data word or that a gap occurred before all expected data words were received.  
12  
WCTERR Word Count Error  
This bit is asserted if command is received with less data words than the command word specifies.  
For example, a receive command for three data words is received with two contiguous data words.  
11  
10  
SYNERR Sync Error.  
This bit is asserted when an incorrect (command/status) sync type occurs in received data words.  
MERR  
Message Error.  
This bit is asserted when message error status change occurs during command processing. See bits  
7 and 11-15 for details.  
9
WASBSY Was Busy.  
This bit is asserted when the terminal responds to the receive command with BUSY status, due to  
global BUSY bit set in 1553 Status Bits Register, or command-specific MKBUSY bit set in the  
descriptor table Control Word. Received data words were buffered normally.  
HOLT INTEGRATED CIRCUITS  
47  
HI-6120, HI-6121  
MESSAGE DATA BUFFERS, Cont.  
Illegal Command Received.  
8
ILCMD  
This bit is asserted when the Illegalization Table bit corresponding to the received command is logic  
1. The Illegalization Table should only contain nonzero values when “illegal command detection” is  
being applied. See section entitled Illegalization Table for further information.  
7
TXRTERR  
RT-RTTransmit RemoteTerminal Error.  
This bit is set when the terminal decodes a valid RT-RT receive command, but one of four potential  
errors is detected in the second command word, CW2: (1) CW2 is addressed to broadcast address  
RT31. (2) the CW2 T/R bit equals 0, (3) the CW2 subaddress is a mode command indicator, 00000 or  
11111, or (4) CW2 has same non-broadcast terminal address as receive command word CW1.  
The TXRTERR bit is also set when status word received from the transmitting terminal is invalid (e.g.,  
parity error) or bits 15:11 in the status word reflect the wrong RTaddress (does not match CW2).  
6
RTRT  
RemoteTerminal to RemoteTerminalTransfer.  
Assertion of this bit indicates the receive command was an error-free RT-to-RTtransfer.  
5
BUSID  
WC4:0  
Bus Identification.  
If this bit equals zero, message was transacted on BusA. If bit equals one, it was transacted on Bus B.  
4-0  
Word Count.  
This 5-bit field contains the word count extracted from the command word. Zero indicates 32 words.  
TRANSMIT SUBADDRESS COMMAND  
MESSAGE INFORMATION WORD  
The external host is responsible for organizing the data packet (i.e., storing N data words) in shared RAM and initializing the  
applicable data pointer. The host must allocate two memory locations at the starting address of the data record for device  
storage of the transmit subaddress Message Information Word andTime-Tag Word.  
Here is an example data structure for a 3-word transmit command. Notice that the Data Pointer points to the data structure  
starting address, not the first data word. The data pointer is located in the transmit subaddress command’s Descriptor Block.  
Data Buffer  
HexAddress  
Word Description  
Word Is Written By  
Data pointer equals 0x0500 ———> 0x0500  
Message Information Word Device, after message completion  
0x0501  
0x0502  
0x0503  
0x0504  
Time-Tag Word  
Data Word 1  
Data Word 2  
Data Word 3  
Host, prior to terminal’s data transmit  
RT  
ASBSY  
GAPEWRRCTERR MERRW  
ILCMD  
RT BUSIDWC4 WC3 WC2 WC1 WC0  
X
X
X
X
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
The following bits comprise the transmit subaddress Message Information Word.  
Bit No.  
15-14  
13  
Mnemonic Function  
—— Not used.  
GAPERR Gap Error.  
Assertion of this bit indicates bus activity was detected immediately after the transmit command  
word, when a gap was expected.  
12  
WCTERR Word Count Error  
This bit is asserted if command is received with unexpected data word(s).  
HOLT INTEGRATED CIRCUITS  
48  
HI-6120, HI-6121  
MESSAGE DATA BUFFERS, Cont.  
Not used.  
11  
——  
10  
MERR  
Message Error.  
This bit is asserted when message error status change occurs during command processing. See bits  
12 and 13 for details.  
9
8
WASBSY Was Busy Status.  
This bit is asserted when the terminal responds to the transmit command with BUSY status, due to  
global BUSY bit set in 1553 Status Bits Register, or command-specific MKBUSY bit set in the  
descriptor table Control Word. No data words were transmitted.  
ILCMD  
Illegal Command Received.  
This bit is asserted when the Illegalization Table bit corresponding to the received command equals  
one. The Illegalization Table should only contain nonzero values when “illegal command detection” is  
being applied. See section entitled Illegalization Table for further information.  
7
6
——  
Not used.  
RTRT  
RemoteTerminal to RemoteTerminalTransfer.  
Assertion of this bit indicates the transmit command was an error-free RT-to-RTtransfer.  
5
BUSID  
WC4:0  
Bus Identification.  
If this bit equals zero, message was transacted on BusA. If bit equals one, it was transacted on Bus B.  
4-0  
Word Count.  
This 5-bit field contains the word count extracted from the command word. Zero indicates 32 words.  
REGARDING MODE COMMAND MESSAGE INFORMATION WORDS  
Mode command data structures in shared RAM are similar to those for subaddresses. Mode codes 0 through 15 (0x0F) do not  
have an associated data word, so data structures for these mode code values have just a Message Information Word and  
Time-Tag Word. The Message Information Word is stored at the memory address specified by the descriptor table Data  
Pointer. Mode codes 16 through 31 (0x10 through 0x1F) have one associated data word. The Message Information Word is  
stored at the memory address specified by the descriptor table Data Pointer, and the Time-Tag Word is stored in the following  
location. The data word is stored at the memory address specified by the Data Pointer plus two locations.  
RECEIVE MODE COMMAND  
MESSAGE INFORMATION WORD  
The receive mode command data structure contains a Message Information Word, a Time-Tag Word and may contain one  
Data Word. If a receive mode command has a data word, the device may apply the data as defined by MIL-STD-1553, plus  
store the received single mode data word at the address specified by the Data Pointer, plus two locations. Refer to data sheet  
section entitled “Mode CommandAction Summary”.  
Here is an example data structure for a receive mode command with data (mode code values 0x10 through 0x1F). Notice that  
the Data Pointer points to the data structure starting address, not the mode data word. The data pointer is located in the receive  
mode command’s Descriptor Block, fully described later:  
Data Buffer  
HexAddress  
Word Description  
Word Is Written By  
Data pointer equals 0x0500 ———> 0x0500  
0x0501  
0x0502  
Message Information Word Device, after message completion  
Time-Tag Word  
Mode Data Word  
Three receive mode commands with data are not defined under MIL-STD-1553B. These are MC16, MC18 and MC19 (mode  
codes 0x10, 0x12 and 0x13 respectively). However the device responds “in form” if illegal command detection is not used  
(corresponding bits in Illegalization Table are logic 0) and the UMCINV bit in Configuration Register 1 is logic 0.  
For mode code commands without data, the data structure contains only the Message Information Word and Time-Tag Word.  
HOLT INTEGRATED CIRCUITS  
49  
HI-6120, HI-6121  
MESSAGE DATA BUFFERS, Cont.  
Here is an example data structure for a receive mode command without data (mode code values 0x00 through 0x0F). Note:  
None of these receive mode commands are defined under MIL-STD-1553B but the device responds “in form” if illegal  
command detection is not used (corresponding bits in Illegalization Table are logic 0) and the UMCINV bit in Configuration  
Register 1 is logic 0. Notice that the data pointer points to the data structure starting address, the message information word.  
The data pointer is located in the receive mode command’s Descriptor Block, fully described later:  
Data Buffer  
HexAddress  
Word Description  
Word Is Written By  
Data pointer equals 0x0500 ———> 0x0500  
0x0501  
Message Information Word Device, after message completion  
Time-Tag Word  
ASBSY  
WCTERR  
IWDEGRARPERR SYNE  
M
R
E
R
RRW  
ILCMD  
BUSIDMC4 MC3 MC2 MC1 MC0  
X
X
X
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
The following bits comprise the receive mode Message Information Word:  
Bit No.  
15  
Mnemonic Function  
—— Not used.  
14  
IWDERR Invalid Word Error.  
Assertion of this bit indicates Manchester error or parity error was observed in a received data word.  
13  
GAPERR Gap Error.  
Assertion of this bit indicates bus activity was detected immediately after a received mode data word  
or that a gap occurred before the data word was received.  
12  
11  
10  
WCTERR Word Count Error  
This bit is asserted if the command is received without expected mode data word, or with extra word.  
SYNERR Sync Error.  
This bit is asserted when incorrect (command/status) sync type occurs in received mode data word.  
MERR  
Message Error.  
This bit is asserted when message error status change occurs during command processing. See bits  
11- 14 for details.  
9
8
WASBSY Was Busy Status.  
This bit is asserted when the terminal responds to the mode command with BUSY status, due to  
global BUSY bit set in 1553 Status Bits Register, or command-specific MKBUSY bit set in the  
descriptor table Control Word.  
ILCMD  
Illegal Command Received.  
This bit is asserted when the Illegalization Table bit corresponding to the received command equals  
one. The Illegalization Table should only contain nonzero values when “illegal command detection” is  
being applied. See section entitled Illegalization Table for further information.  
7-6  
5
——  
Not used.  
BUSID  
Bus Identification.  
If this bit equals zero, message was transacted on BusA. If bit equals one, it was transacted on Bus B.  
4-0  
MC4:0  
Mode Code.  
This 5-bit field contains the mode code extracted from the command word.  
HOLT INTEGRATED CIRCUITS  
50  
HI-6120, HI-6121  
MESSAGE DATA BUFFERS, Cont.  
TRANSMIT MODE COMMAND  
MESSAGE INFORMATION WORD  
The transmit mode command data structure contains a Message Information Word, a Time-Tag word and may contain one  
Data Word. For mode commands with associated data word (mode codes 16-31 decimal) the host is responsible for loading  
the Mode Command Data Table before transmit mode commands are received (e.g., Transmit Vector Word mode code). Two  
mode codes have internally generated data words: MC18 “Transmit Last Command” and MC19 “Transmit BIT Word”. For  
these, the device automatically transmits the data word then copies the transmitted data value to the stored data structure.  
Here is an example data structure for a transmit mode command with data (mode code values 0x10 through 0x1F). This  
applies to MC16 “Transmit Vector Word”. Notice that the data pointer points to the data structure starting address, not the  
mode data word. The data pointer is located in the transmit mode command’s Descriptor Block, fully described later:  
Data Buffer  
HexAddress  
Word Description  
Word Is Written By  
Data pointer equals 0x0500 ———> 0x0500  
0x0501  
0x0502  
Message Information Word Device, after message completion  
Time-Tag Word  
Mode Data Word  
Host, prior to terminal’s data transmit  
(except MC18, MC19 are written  
by the device after completion)  
Three transmit mode commands with data are not defined under MIL-STD-1553B. These are MC17, MC20 and MC21 (mode  
codes 0x11, 0x14 and 0x15 respectively). However the device responds “in form” if illegal command detection is not used  
(corresponding bits in Illegalization Table are logic 0) and the UMCINV bit in Configuration Register 1 is logic 0.  
For mode code commands without data, the data structure contains only the Message Information Word and Time-Tag Word.  
Here is an example data structure for a transmit mode command without data (mode code values 0x00 through 0x0F). Again,  
the data pointer points to the data structure starting address. The data pointer is located in the transmit mode command’s  
Descriptor Block, fully described later:  
Data Buffer  
HexAddress  
Word Description  
Word Is Written By  
Data pointer equals 0x0500 ———> 0x0500  
0x0501  
Message Information Word Device, after message completion  
Time-Tag Word  
ASBSY  
MERRW  
WCTERR  
GAPERR  
ILCMD  
BUSIDMC4 MC3 MC2 MC1 MC0  
X
X
X
X
X
MSB 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
LSB  
The following bits comprise the mode transmit Message Information Word:  
Bit No.  
15-14  
13  
Mnemonic Function  
---- Not used.  
GAPERR Gap Error.  
This bit is high when bus activity was detected immediately after the mode command word, when a  
gap was expected.  
12  
WCTERR Word Count Error  
This bit is asserted if command is received with unexpected data word(s).  
11  
10  
----  
Not used.  
MERR  
Message Error.  
This bit is asserted when message error status change occurs during command processing. See bits  
12-13 for details.  
HOLT INTEGRATED CIRCUITS  
51  
HI-6120, HI-6121  
MESSAGE DATA BUFFERS, Cont.  
WASBSY Was Busy Status.  
9
This bit is asserted when the terminal responds to the mode command with BUSY status, due to  
global BUSY bit set in 1553 Status Bits Register, or command-specific MKBUSY bit set in the  
descriptor table Control Word. No mode data word was transmitted.  
8
ILCMD  
Illegal Command Received.  
This bit is asserted when the Illegalization Table bit corresponding to the received command is logic  
1. The Illegalization Table should only contain nonzero values when “illegal command detection” is  
being applied. See section entitled Illegalization Table for further information.  
7-6  
5
——  
Not used.  
BUSID  
Bus Identification.  
If this bit equals zero, message was transacted on BusA. If bit equals one, it was transacted on Bus B.  
4-0  
MC4:0  
Mode Code.  
This 5-bit field contains the mode code extracted from the command word.  
PING-PONG DATA BUFFERING  
DOUBLE-BUFFERED (PING-PONG) MODE  
by the next command. DPB equals logic 0 means Data  
Pointer A is used next; DPB equals logic 1 means Data  
Pointer B is used next. For ping-pong, Data Pointers A and  
B are static values pointing to the first address in each  
buffer.At the conclusion of error-free message processing,  
the Control Word DPB bit is inverted so the next command  
“ping-pongs” to the other data buffer. Each new message  
to the subaddress or mode code overwrites message data  
and information words written two messages back. The  
DPB bit does not toggle when a message ends in error, or if  
the command was illegal, or if Busy status applied for the  
received command. In these cases, the next command will  
overwrite the same buffer. Figure 11 is a general illustration  
of ping-pong buffer mode. Figure 12 shows a specific  
example.  
Ping-pong buffer mode is a method for storing message  
and time-tag information and data associated with  
messages. Each unique MIL-STD-1553 subaddress and  
mode code is assigned a pair of data buffers for transmit  
commands and a pair of data buffers for receive  
commands. The device retrieves buffer data for transmit  
commands, or stores buffer data for receive commands.  
During ping-pong operation, the device alternates  
message storage between Data Buffer A and Data Buffer  
B, on a message-by-message basis.  
When a subaddress or mode command uses ping-pong  
data buffer mode, its 4-word descriptor block in the  
DescriptorTable is defined as follows:  
Descriptor Word 1  
Descriptor Word 2  
Descriptor Word 3  
Descriptor Word 4  
Control Word  
Data PointerA  
Data Pointer B  
Broadcast Data Pointer  
PING-PONG ENABLE / DISABLE HANDSHAKE  
Because ping-pong messages and host buffer servicing  
are asynchronous, there is potential for “data collision”.  
Here is a data collision example: The host reads data from  
an earlier message while the device simultaneously writes  
new message data to the same buffer. The host reads a  
mix of new and old message data. Collisions can occur for  
both transmit and receive messages.  
If Descriptor Word 1 is stored at memory address N,  
Descriptor Word 2 is stored at address N+1, and the other  
two words are stored at addresses N+2 and N+3.  
Prior to starting terminal operation, enable ping-pong  
buffering for any subaddress (or mode code) by asserting  
the PPEN bit and negating the STOPP bit in the descriptor  
Control Word. When the device detects ping-pong is  
selected (PPEN = 1) and enabled (STOPP = 0), it asserts  
the Control Word PPON bit to confirm ping-pong is active.  
A handshake scheme lets the external host  
asynchronously service ping-pong data buffers without  
data collision. To off-load or load a subaddress (or mode  
code) buffer, the application software performs the  
following sequence:  
(a) Host asserts the Control Word STOPP bit to suspend  
ping-pong operation for the subaddress. When the device  
recognizes STOPP bit assertion, it negates the PPON bit  
During ping-pong operation, the RT determines the active  
data buffer at the beginning of message processing. The  
Control Word DPB bit indicates the data pointer to be used  
HOLT INTEGRATED CIRCUITS  
52  
HI-6120, HI-6121  
PING-PONG DATA BUFFERING, Cont.  
Data Word 32  
Data Words 2-31  
Data Word 1  
Time-Tag Word  
Data Word 32  
Broadcast Message  
(if NOTICE2 is asserted)  
Data Words 2-31  
Message Info Word  
Data Word 1  
Time-Tag Word  
Subaddress  
Buffer Space  
for Broadcast  
(Optional)  
Message #2  
Message #4  
Message #6  
etc.  
Message Info Word  
Assigned  
Subaddress  
Data Buffer B  
B’cast Data Pointer  
Data Pointer B  
Increasing  
Memory  
Address  
Data Pointer A  
Control Word  
Data Word 32  
Data Words 2-31  
Data Word 1  
Time-Tag Word  
Descriptor Block  
for Subaddress  
Message #1  
Message #3  
Message #5  
etc.  
Message Info Word  
Assigned  
Subaddress  
Data Buffer A  
Memory Address for the Applicable  
Subaddress Block is Derived From  
the Decoded Command Word  
Figure 11. Illustration of Ping-Pong Buffer Mode  
Message processing alternates between Data Buffers A and B. Upon successful message completion, the DPB bit in  
Descriptor Control Word is updated so next message uses other buffer. Buffers are overwritten every other message.  
Separate buffer for broadcast messages is optional. There is no alternate buffer for successive broadcast messages.  
HOLT INTEGRATED CIRCUITS  
53  
HI-6120, HI-6121  
PING-PONG DATA BUFFERING, Cont.  
to acknowledge ping-pong is disabled. While PPON  
remains low, the last written (or read) data buffer is  
protected against device updates. During this time, new  
messages use the active buffer indicated by the Control  
Word DPA bit. Recurring messages repeatedly use the  
same buffer until ping-pong resumes.  
common “bit bucket” broadcast buffer. A two word buffer is  
sufficient for storing the MIW andTime-Tag Word.  
When using ping-pong mode, there are two ways to handle  
broadcast messages, when broadcast is enabled:  
Option 1 for Ping-Pong Mode Broadcast Messages:  
This option isolates broadcast message information in the  
broadcast data buffer. If the descriptor Control Word IBRD  
bit and Interrupt Enable Register IBRD bit are both set,  
reception of broadcast messages generates an INTMES  
host interrupt. To prevent data loss, the broadcast data  
buffer must be serviced before the next broadcast  
message occurs. Broadcast messages do not affect non-  
broadcast message ping-pong; the Control Word DPB bit  
does not toggle after broadcast message completion.  
(b) Host services the last-used data buffer. If the Control  
Word DPB bit equals logic 1, the last command used Buffer  
A. The host application software off-loads or loads inactive  
Buffer A while the remote terminal uses active Buffer B for  
new message(s). If the DPB bit equals logic 0, the last  
command used Buffer B. The host application software off-  
loads or loads inactive Buffer B while the remote terminal  
uses active Buffer A for any new messages. Each new  
receive message overwrites buffer contents from the last  
receive message. To avoid possible data loss, host buffer  
servicing should be timed for completion before a second  
message can occur.  
Option 1 Setup: At initialization, host asserts the  
NOTICE2 bit in Configuration Register 1 and sets the IBRD  
(Interrupt Broadcast Received) bit in descriptor Control  
Word(s). The IBRD bit is asserted in the Interrupt Enable  
Register.  
(c) Host negates the Control Word STOPP bit to resume  
ping-pong operation for the subaddress. When the RT  
recognizes the STOPP bit is reset, it sets the PPON bit to  
acknowledge ping-pong is again active. As long as PPON  
remains set, the device alternates between data buffers A  
and B for new messages.  
When a broadcast command is received, message  
information and data is stored in the broadcast data buffer  
and an INTMES interrupt is generated. The host must read  
the Interrupt Log to determine the originating subaddress  
(or mode code), then service the broadcast data buffer for  
that subaddress (or mode code) before another broadcast  
message to the same subaddress (or mode code) arrives.  
BROADCAST MESSAGE HANDLING  
IN PING-PONG MODE  
For MIL-STD-1553B Notice II compliance, a remote  
terminal should be capable of storing data from broadcast  
messages separately from non-broadcast message data.  
Some applications may not include this requirement. The  
standard does not stipulate where data separation should  
occur (e.g., within the RT or within the external host) so the  
device provides alternative strategies.  
Option 2 for Ping-Pong Mode Broadcast Messages:  
The second alternative stores both broadcast and non-  
broadcast message information in the ping-pong data  
buffers A and B. IWA interrupts can signal arrival of any  
new message. The RT handles broadcast messages just  
like non-broadcast messages, except the Message  
Information Word BCAST bit is asserted to identify  
broadcast messages during host buffer servicing. All  
messages toggle the Control Word DPB bit in message  
post-processing. For Notice II compliance, separation of  
broadcast and non-broadcast data occurs within the host.  
When the NOTICE2 bit in Configuration Register 1 is 1 and  
the BCSTINV bit is 0, ping-pong mode subaddresses (or  
mode codes) will buffer data words from broadcast and  
non-broadcast messages separately. Broadcast message  
information and data are stored in the broadcast data  
buffer; non-broadcast message information and data are  
stored in ping-pong buffers A and B. Since there is just one  
broadcast data buffer, the NOTICE2 option treats  
broadcast messages as exceptions to normal ping-pong  
mode. When using the NOTICE2 option, broadcast data  
buffer servicing should have high priority, because a  
closely following broadcast message will overwrite the  
broadcast buffer.  
Option 2 Setup: At initialization, host negates the  
NOTICE2 bit in Configuration Register 1. If IWA interrupts  
are used, the host asserts the descriptor Control Word IWA  
(Interrupt When Accessed) bit 14 and the corresponding  
bit is asserted in the Interrupt Enable Register. Using this  
option, the IBRD interrupt is probably not used.  
The host typically services the ping-pong data buffers A  
and B whenever a message is transacted. Using the setup  
above, this occurs whenever the subaddress IWAinterrupt  
generates an INTMES interrupt output for the host. The  
host must read the Interrupt Log to determine the  
originating subaddress or mode code. The applicable data  
buffer is indicated by the DPB bit in the Receive Control  
Word. The Message Information Word BCAST bit is  
asserted if the message was broadcast.  
Every mode command and subaddress (including  
transmit subaddresses) must have an assigned valid  
broadcast data pointer when NOTICE2 is asserted.  
When the NOTICE2 bit in Configuration Register 1 is 1 and  
the BCSTINV bit is 0, reception of a broadcast-transmit  
message updates the Message Information and Time-Tag  
Words for the assigned broadcast buffer, but no data is  
transmitted on the bus. Since broadcast-transmit is not  
allowed, multiple transmit subaddresses may share a  
HOLT INTEGRATED CIRCUITS  
54  
HI-6120, HI-6121  
PING-PONG DATA BUFFERING, Cont.  
0x0565  
Device sets Control Word BCAST bit  
(DPB bit remains static)  
IBRD interrupt is generated  
Data Word 32  
Data Words 2-31  
0x0547 - 0x0564  
0x0546  
Data Word 1  
Assigned  
Subaddress  
Broadcast  
Data Buffer  
Time-Tag Word BC  
Msg Info Word BC  
0x0545  
Receive Message #2  
Broadcast, 32 Data Words  
0x0544  
0x0543  
Device resets Control Word  
DPB and BCAST bits  
Data Word 32  
Data Words 2-31  
0x0525 - 0x0542  
0x0524  
Data Word 1  
Time-Tag Word B  
Msg Info Word B  
Assigned  
Subaddress  
Data Buffer B  
0x0523  
Receive Message #3  
Non-Broadcast, 32 Data Words  
0x0522  
0x0521  
Device sets Control Word DPB bit  
Data Word 32  
Data Words 2-31  
0x0503 - 0x0520  
0x0502  
Data Word 1  
Time-Tag Word A  
Msg Info Word A  
Assigned  
Subaddress  
Data Buffer A  
0x0501  
Receive Message #1  
Non-Broadcast, 32 Data Words  
0x0500  
RAM  
Address  
Message #4 also uses  
this buffer, if not broadcast  
Increasing  
Memory  
Address  
B’cast Data Pointer  
Data Pointer B  
Broadcast Data Pointer = 0x0544 start address in RAM  
Data Pointer B = 0x0522  
Data Pointer A = 0x0500  
Control Word = 0x2010  
Buffer B start address in RAM  
Buffer A start address in RAM  
Ping-Pong Mode, IBRD Interrupt  
Data Pointer A  
Control Word  
Initialized Descriptor Values  
Descriptor Block  
for a  
Receive Subaddress  
Figure 12. Ping-Pong Buffer Mode Example for a Receive Subaddress  
Following reset (which resets Control Word DPB bit), the subaddress transacts 4 commands of 32 data words each.  
The NOTICE 2 option is enabled so the device segregates data from broadcast and non-broadcast messages.  
Message #2 is a broadcast command, while the other three messages are non-broadcast. Notice that the broadcast  
message does not affect DPB bit, but the following message resets BCAST bit. The interspersed broadcast command  
does not affect alternation between Buffer A and Buffer B.  
HOLT INTEGRATED CIRCUITS  
55  
HI-6120, HI-6121  
INDEXED DATA BUFFERING  
INDEXED DATABUFFER MODE  
Also called “single buffer mode”, indexed buffering is one  
method for storing message and time-tag information and  
data associated with messages. Buffer mode is selected  
for each subaddress or mode code in the Descriptor Table  
Control Words. Indexed mode is enabled when Control  
Word PPEN, CIR1EN and CIR2EN bits are all zero.  
If Descriptor Word 1 is stored at memory address N,  
Descriptor Word 2 is stored at address N+1, and the other  
two words are stored at addresses N+2 and N+3.  
As the name implies, all message information and data is  
stored in a single buffer, indexed by descriptor word Data  
Pointer A. The descriptor Control Word DPB bit is “don’t  
care”. The host initializes the desired message count in  
descriptor INDX word. During message processing, the  
device retrieves or stores data words from the address  
specified by descriptor Data Pointer A, automatically  
incrementing the pointer address as words are read or  
stored. Data Pointer A is updated during command post-  
processing with the current buffer address unless the  
message index count in descriptor INDX (word 3 of  
When a subaddress or mode command uses the indexed  
data buffer mode, its 4-word descriptor block in the  
DescriptorTable is defined as follows:  
Descriptor Word 1  
Descriptor Word 2  
Descriptor Word 3  
Descriptor Word 4  
Control Word  
Data PointerA  
INDX Index Word  
Broadcast Data Pointer  
Data Word N  
Data Word(s)  
Data Word 1  
Increasing  
Memory  
Address  
Time-Tag Word  
Data Word N  
Data Word(s)  
Next  
Message  
Message Info Word  
Data Word 1  
Time-Tag Word  
Data Word N  
Data Word(s)  
Broadcast  
Message Info Word  
B’cast Data Pointer  
INDX Index Count  
Data Pointer A  
Data Word 1  
Time-Tag Word  
Message  
if NOTICE2  
is asserted  
Subaddress  
Buffer Space  
for Broadcast  
(Optional)  
Current  
Message  
Message Info Word  
Control Word  
Data Word N  
Data Word(s)  
Data Word 1  
Time-Tag Word  
Descriptor Block  
for Subaddress  
Preceding  
Message  
Message Info Word  
Assigned  
Subaddress  
Buffer Space  
Memory Address for the Applicable  
Subaddress Block is Derived From  
the Decoded Command Word  
Upon successful message completion, if non-zero the INDX count in Descriptor Word 3 is decremented.  
If decremented result is non-zero, Data Pointer A is adjusted so next message is stored above just-completed message.  
If decremented INDX is zero, Data Pointer A remains static, and IXEQZ interrupt occurs if enabled in Control Word.  
Figure 13. Illustration of Single-Buffer Indexed Mode  
HOLT INTEGRATED CIRCUITS  
56  
HI-6120, HI-6121  
INDEXED DATA BUFFERING, Cont.  
descriptor block) decrements to zero upon completion of  
the message. Figure 13 is a general illustration of indexed  
single buffer mode. Figure 14 shows a specific example.  
There are two ways to deal with broadcast messages in  
indexed buffer mode:  
Option 1 for Index Mode Broadcast Messages:  
To set up a terminal subaddress to buffer multiple  
messages, the host writes the desired index count (INDX)  
to subaddress descriptor word 3. The initial INDX value  
ranges from zero to 3FF hex (1023) messages. The device  
decrements the INDX count each time an error-free  
message is transacted, and the data pointer is updated to  
the first memory address to be used for the next message.  
If INDX decrements from one to zero and Control Word  
IXEQZ bit 15 is asserted, the IXEQZ bit is set in the  
Interrupt Pending Register. If the corresponding bit in the  
Interrupt Enable Register is asserted, an INTMES interrupt  
is generated when INDX decrements from one to zero.  
The first alternative isolates broadcast message  
information in the broadcast data buffer. If the descriptor  
Control Word IBRD bit and Interrupt Enable Register IBRD  
bit are both set, reception of broadcast messages  
generates an INTMES interrupt to the host. The broadcast  
data buffer must be processed before another broadcast  
message arrives to prevent loss of data. Broadcast  
messages do not decrement the INDX register, and Data  
Pointer A is not updated in message post-processing. This  
scheme may be well suited for Single Message Mode  
(INDX = 0) when the host can reliably service either the  
broadcast data buffer or data buffer A before the next  
receive message arrives for the same subaddress (or  
mode code).  
INDX counter decrement does not occur if the command  
was illegalized or if INDX already equals zero. Once INDX  
equals zero, further commands will overwrite the last-  
written data buffer block and the data pointer value is not  
updated after successful message completion.  
Option 1 Setup:At initialization, host asserts NOTICE2 bit  
in Configuration Register 1 and sets the Control Word  
IBRD (Interrupt Broadcast Received) bit for each index  
mode descriptor block. The IBRD bit is also asserted in the  
Interrupt Enable Register.  
When using Index Mode with a non-zero INDX value, the  
host must remember the initial Data PointerAaddress. The  
Data Pointer A word is not automatically reinitialized to the  
buffer start address when INDX decrements from 1 to 0.  
When a broadcast command is received, message  
information and data are stored in the broadcast data  
buffer. If descriptor Control Word IBRD bit is set, an  
INTMES interrupt is generated. The host must read the  
Interrupt Log to determine the originating subaddress (or  
mode code) then service the broadcast data buffer for that  
subaddress (or mode code) before the next broadcast  
message to the same subaddress (or mode code) arrives.  
SINGLE MESSAGE MODE  
When Index Mode is initialized with an INDX value of zero,  
the subaddress or mode code is operating in “Single  
Message Mode”. Here, the same data block is repeatedly  
over-read (for transmit data) or overwritten (for receive or  
broadcast data). The DPApointer is not updated at the end  
of each message. The chief advantage of single message  
mode is simplicity. In comparison to other data buffering  
options, the single message buffer uses an absolute  
minimum amount of memory space. The IXEQZ interrupt  
cannot be used for this scheme (INDX is always zero) but  
IWAinterrupts may be used. Single message mode is best  
suited to synchronous data transfer where the host  
processor can reliably read or write new message data  
prior to the start of the next message to the same  
subaddress or mode code.  
Option 2 for Index Mode Broadcast Messages:  
The second alternative stores both broadcast and non-  
broadcast message information in data buffer A. Optional  
IBRD interrupts can signal arrival of broadcast messages.  
The RT handles broadcast messages just like non-  
broadcast messages, except the Message Information  
Word BCAST bit is asserted to identify broadcast  
messages during host buffer servicing. All messages  
decrement the INDX register and Data PointerAis updated  
in message post-processing. This scheme is compatible  
with Single Message Mode or conventional N-message  
indexing. For Notice II compliance, separation of  
broadcast and non-broadcast data occurs within the host.  
BROADCAST MESSAGE HANDLING IN INDEX MODE  
For MIL-STD-1553B Notice II compliance, a remote  
terminal should be capable of storing data from broadcast  
messages separately from non-broadcast message data.  
Some applications may not include this requirement. The  
standard does not stipulate where data separation should  
occur (e.g., within the RT or within the external host) so the  
device supports alternative strategies.  
Option 2 Setup: At initialization, host negates the  
NOTICE2 bit in Configuration Register 1. If broadcast  
interrupts are used, the Control Word IBRD (Interrupt  
Broadcast Received) bit is asserted at each desired index  
mode descriptor block . The IBRD bit is also asserted in the  
Interrupt Enable Register.  
When the NOTICE2 bit is logic 1 in Configuration Register  
1, broadcast message data is stored in a broadcast data  
buffer assigned for the subaddress or mode command.  
Each subaddress or mode command must have an  
assigned, valid non-zero broadcast buffer address.  
Non-broadcast message data is stored in Data BufferA.  
Using option 2, the host has several options for servicing  
data bufferA: (a) when INDX decrements from one to zero  
(using the IXEQZ interrupt), (b) when a broadcast  
message occurs (using the IBRD interrupt) or (c) when any  
message arrives (using the IWAinterrupt).  
HOLT INTEGRATED CIRCUITS  
57  
HI-6120, HI-6121  
INDEXED DATA BUFFERING, Cont.  
For Message #2,  
Index decrements to zero.  
Data Pointer A = 0x0505 (static)  
IXEQZ Interrupt is generated  
Data Word 4  
0x050A  
0x0509  
0x0508  
0x0507  
0x0506  
0x0505  
0x0504  
0x0503  
0x0502  
0x0501  
0x0500  
For Message #3 and beyond,  
the data buffer is overwritten.  
Index remains zero (static)  
Data Pointer A = 0x0505 (static)  
and no IXEQZ interrupt occurs.  
Data Word 3  
Data Word 2  
Data Word 1  
Time-Tag Word 2  
Msg Info Word 2  
Messages #2, #3, etc  
Receive 4 Words  
Data Word 3  
Data Word 2  
Index decrements to one  
Data Pointer A = 0x0505  
Data Word 1  
Time-Tag Word 1  
Msg Info Word 1  
Message #1  
Receive 3 Words  
Index equals two  
RAM  
Address  
Assigned  
Receive  
Subaddress  
Buffer  
Increasing  
Memory  
Address  
Don’t care  
B’cast Data Pointer  
INDX Index Count  
Data Pointer A  
Broadcast Data Pointer = 0xXXXX  
Index = 0x0002  
Initialize index for 2 messages  
Buffer start address in RAM  
Index Mode, IXEQZ Interrupt  
Data Pointer A = 0x0500  
Control Word = 0x8000  
Control Word  
Initialized Descriptor Values  
Descriptor Block  
for a  
Receive Subaddress  
Figure 14. Indexed Buffer Mode Example for a Receive Subaddress  
Assume Broadcast not enabled  
HOLT INTEGRATED CIRCUITS  
58  
HI-6120, HI-6121  
CIRCULAR BUFFER MODE 1  
CIRCULAR BUFFER MODE 1  
have a unique circular buffer assignment. The RT decodes  
the command word T/R bit, subaddress field and word  
count / mode code field to select the unique command  
descriptor block containing the Control Word, SA pointer,  
CApointer and EApointer.  
The device offers two circular data buffer modes as  
alternatives to ping-pong and indexed buffering. These  
circular buffer options only apply for subaddress  
commands, not mode code commands. Circular buffering  
simplifies software servicing of the remote terminal when  
implementing bulk data transfers. A circular buffer mode  
can be selected for any subaddress by properly initializing  
its descriptor Control Word. Circular Buffer Mode 1 is  
selected when descriptor Control Word PPEN and  
CIR2EN bits are both 0, and the CIR1EN bit is logic 1.  
For receive messages, the device stores the Message  
Information word to the address specified by CA, the Time-  
Tag word into CA+1 and the data into the next “N” locations  
starting with CA+2. For transmit messages, the device  
stores the Message Information word to the address  
specified by CA and the Time-Tag word into CA+1.  
Retrieval of data for transmission starts at address CA+2.  
When entering multiple transmit command data packets  
into the circular buffer, delimit each data packet with two  
reserved memory locations. The device stores the  
Message Information word and Time-Tag word into the  
reserved locations when processing the command.  
When a subaddress uses circular buffer mode 1, its four  
word block in the DescriptorTable is defined as follows:  
Descriptor Word 1  
Descriptor Word 2  
Descriptor Word 3  
Descriptor Word 4  
Control Word  
SA (buffer start address)  
CA (buffer current address)  
EA (buffer end address)  
Message processing for all commands begins with the  
device reading the unique descriptor block for the  
subaddress or mode code specified by the T/R bit,  
subaddress and word count fields in the received  
command word.  
If Descriptor Word 1 is stored at memory address N,  
Descriptor Word 2 is stored at address N+1, and the other  
two words are stored at addresses N+2 and N+3.  
Figure 15 provides a generalized illustration of Circular  
Buffer Mode 1, while Figure 16 shows a specific example.  
Circular Buffer Mode 1 uses a single user-defined buffer  
that merges all transmit or receive data, along with  
message information. Two words (Message Information  
and Time-Tag) are stored at the beginning of the block for  
each message, followed by the message data word(s).  
The Mode 1 buffer pointers roll over (are reset to their base  
addresses) when the allocated data buffer memory is full.  
For receive messages, the device stores “N” received data  
words in the circular data buffer. The first data word  
received is stored at the location specified by the CA  
pointer +2. After message completion, the device stores  
the Message Information word and Time-Tag words to  
addresses CA and CA+1 respectively. If no errors were  
detected, the device updates descriptor CA register. If the  
next address location (last stored data word +1) is less  
than or equal to EA, CA is updated to (last stored address  
+1). If the next address location (last stored data word +1)  
is greater than EA, the data buffer is full (or empty); CA is  
updated to the SA value. If descriptor Control Word IXEQZ  
bit is asserted (and if Interrupt Enable Register IXEQZ bit is  
asserted) the device generates an interrupt to indicate full  
receive buffer by asserting the INTMES interrupt output.  
For each valid receive message, the device enters a  
Message Information word, Time-Tag word and data  
word(s) into the circular receive buffer. For each valid  
transmit message, the device enters a Message  
Information word and a Time-Tag word into reserved  
memory locations within the circular transmit buffer. The  
device automatically controls the wrap around of circular  
buffers.  
Although all messages store Message Information and  
Time-Tag words, no data is stored if the message ended  
with error, or if the Busy status bit was set or if the  
commend was illegal (example: illegalized word count).  
Such messages do not update CA, so the next message  
overwrites the same buffer space.  
Two pointers define circular buffer length: start of buffer  
(lowest address) and end of buffer (highest address). User  
specifies the start of buffer (SA) by writing the lowest  
address value into the second word of a unique  
subaddress descriptor block. The user defines the bottom  
of the buffer (EA) by writing the highest address value to  
the fourth word of that unique descriptor block. Both SA  
and EA remain static during message processing. The  
third word in the descriptor block identifies the current  
address CA (i.e., last accessed address plus one). The  
circular buffer wraps to the start address after completing a  
message that results in CA being greater than or equal to  
EA. If CA increments past EA during message processing,  
the device will access memory addresses greater than the  
EA value. Reserve 33 address locations past the EA  
address to accommodate a worst-case 32 data word  
message with a record starting at address = EA minus 1.  
Each receive subaddress and transmit subaddress may  
For transmit commands, the device begins transmission of  
data retrieving the first data word stored at address CA+2.  
(Reminder: addresses CA and CA+1 are reserved for the  
Message Information and Time-Tag words.) When  
message processing is complete, the device writes the  
Message Information and Time-Tag words into the buffer. If  
no errors were detected, the device updates descriptor CA  
register. If the next address location (last retrieved data  
word +1) is less than or equal to EA, CA is updated to (last  
retrieved address +1). If the next address location (last  
retrieved data word +1) is greater than EA, the transmit  
data buffer is empty; CA is updated to the SA value. If the  
HOLT INTEGRATED CIRCUITS  
59  
HI-6120, HI-6121  
CIRCULAR BUFFER MODE 1, Cont.  
descriptor Control Word IXEQZ bit is asserted (and if the  
Interrupt Enable Register IXEQZ bit is asserted) the device  
indicates “transmit buffer empty” by asserting the INTMES  
interrupt output.  
not result in bus transmission. However these messages  
update the Message Information Word addressed by the  
Current Address (CA) pointer (and following Time-Tag  
Word) but afterwards, the CA pointer remains  
unchanged. The next transmit command to the same  
subaddress, whether broadcast or not, overwrites the  
Message Information and Time-Tag Word locations written  
by the previous broadcast transmit command.  
Circular Buffer Mode 1 does not support NOTICE2  
segregation of broadcast data, even when the NOTICE2  
bit equals 1 in Configuration Register 1. Data from  
broadcast and non-broadcast receive commands is stored  
in the same buffer. The BCAST bit in the Message  
Information Word reflects broadcast or non-broadcast  
status for each stored message. If broadcast messages  
are not expected during data block transmission, the host  
can illegalize broadcast commands for the subaddress.  
Broadcast illegalization can be done either permanently, or  
only when data block transmission is scheduled.  
End  
Data Word N  
Address  
Data Word(s)  
Data Word 1  
For transmit subaddresses using Circular Buffer Mode 1,  
occurrences of broadcast-transmit commands to RT31 do  
Time-Tag Word  
Last Message  
Message Info Word  
in Data Block  
More Messages  
in Data Block  
Data Word N  
Data Word(s)  
Data Word 1  
Time-Tag Word  
End Address  
Current  
Message  
Current  
Address  
Message Info Word  
Current Address  
Start Address  
Control Word  
More Messages  
in Data Block  
Data Word N  
Data Word(s)  
Descriptor Block  
for Subaddress  
Data Word 1  
Time-Tag Word  
Memory Address for the Applicable  
Subaddress Block is Derived From  
the Decoded Command Word  
Start  
Address  
First Message  
in Data Block  
Message Info Word  
Assigned  
Subaddress  
Circular  
Increasing  
Memory  
Address  
Data Buffer  
Figure 15. Illustration of Circular Buffer Mode 1  
Descriptor block is initialized so Current Address equals buffer Start Address. After each successful message  
transaction, Current Address is adjusted to point past last data word accessed. If adjusted Current Address points  
past End Address, the Current Address is reinitialized to match Start Address and an optional interrupt is  
generated to notify host that the pre-determined data block was fully transacted.  
HOLT INTEGRATED CIRCUITS  
60  
HI-6120, HI-6121  
CIRCULAR BUFFER MODE 1, Cont.  
0x0565  
(1 + Data Word 32 address) ³ End Address.  
Device updates Current Address to  
equal the Start Address, 0x0500.  
IXEQZ interrupt is generated.  
Data Word 32  
Data Words 2-31  
0x0547 - 0x0564  
0x0546  
Buffer End  
Address  
Data Word 1  
Time-Tag Word 3  
Msg Info Word 3  
0x0545  
Receive Message #3  
32 Data Words  
0x0544  
0x0543  
(1 + Data Word 32 address) < End Address.  
Device updates Current Address to 0x0544.  
Data Word 32  
Data Words 2-31  
0x0525 - 0x0542  
0x0524  
Data Word 1  
Time-Tag Word 2  
Msg Info Word 2  
0x0523  
Receive Message #2  
32 Data Words  
0x0522  
0x0521  
(1 + Data Word 32 address) < End Address.  
Device updates Current Address to 0x0522.  
Data Word 32  
Data Words 2-31  
0x0503 - 0x0520  
0x0502  
Data Word 1  
Time-Tag Word 1  
Msg Info Word 1  
0x0501  
Receive Message #1  
32 Data Words  
Buffer Start  
Address  
0x0500  
RAM  
Address  
Unless serviced by host  
after Message #3 Interrupt,  
Message #4 will overwrite  
buffer, starting at 0x0500  
End Address  
Current Address  
Start Address  
Control Word  
End Address = 0x0546  
Buffer end address in RAM  
Increasing  
Memory  
Address  
Current Address = 0x0500 Buffer current address in RAM  
Start address = 0x0500  
Control Word = 0x8001  
Buffer start address in RAM  
Circular Mode 1, IXEQZ Interrupt  
Initialized Descriptor Values  
Descriptor Block  
for a  
Receive Subaddress  
Figure 16. Circular Buffer Mode 1 Example for a Receive Subaddress  
Unlike Indexed mode, Data Block completion is based on Buffer Full / Buffer Empty, not number of messages.  
Buffer size was purposely sized to yield remaining capacity after 2 full-count messages, to illustrate device behavior.  
The circular buffer should have a 33-word pad beyond its End Address to deal with buffer overrun without data loss.  
HOLT INTEGRATED CIRCUITS  
61  
HI-6120, HI-6121  
CIRCULAR BUFFER MODE 2  
CIRCULAR BUFFER MODE 2  
word in the descriptor block is the Control Word. The  
second and third words in the descriptor are the Start  
Address (SA) and Current Address (CA) pointers. The  
Message Information Buffer Address (MIBA) points to the  
storage location for the Message Information Word from  
the next occurring message.  
Circular Buffer Mode 2 segregates message data and  
message information in separate host-defined buffers.  
Separating data from message information simplifies the  
host software that loads or unloads the data to or from the  
buffer. After a predetermined number of messages has  
been transacted, buffer address pointers for data and  
message information are automatically reset to their base  
addresses. Figure 17 is a generalized illustration of  
Circular Buffer Mode 2, while Figure 18 shows a specific  
example.  
Each time a message is completed, the device writes a  
new Message Information Word and Time-Tag Word in the  
MIB (Message Information Buffer) at the MIBA address  
and following location, respectively. The MIBA pointer is  
not updated if message error occurred, if the Busy status  
bit was set, or if the command was illegalized (for example  
an illegal word count expressed in the command word.)  
For these situations, the Message Information and Time-  
Tag words are still written, but MIB updates for the  
following message will overwrite the just-written Message  
Information andTime-Tag word addresses.  
Circular Buffer Mode 2 is selected when the Control Word  
PPEN bit is zero and the CIR2EN bit is logic 1. When the  
CIR2EN bit is high, the CIR1EN bit is don't care. The  
descriptor Control Word DPB bit is not used.  
Any receive subaddress using circular buffer mode 2 has  
two circular buffers: a data storage buffer and a message  
information buffer. A separate buffer pair may be used for  
transmit commands to the same subaddress, if it also uses  
circular buffer mode 2. Each transmit and receive  
subaddress using circular buffer mode 2 may have unique  
data buffer and message info buffer assignments. Careful  
management (involving the bus controller) may allow  
buffer sharing, as long as multiple message sequences to  
a given subaddress are not interrupted by messages to  
other subaddresses that use the same buffer space.  
For error-free receive messages, received data words are  
stored in the data buffer after message completion,  
starting at the CA address value. The CA value is then  
updated for next-message readiness.  
After writing the two MIB words, the device updates the  
MIBA value to show the buffer address to be used by the  
next message. Until the predetermined number of error-  
free messages is transacted, the MIBA value is double-  
incremented at each update. Before updating the MIBA in  
Descriptor Word 4, the pre-existing MIBA value is  
incremented once then checked for ‘full count,” occurring  
when all N low-order address bits initialized to zero  
(explained below) become N “one” bits. Full count means  
the predetermined number of successful messages was  
completed. When this occurs, the CAand MIB pointers are  
automatically written to their initialized values by the  
device.  
When a subaddress uses circular buffer mode 2, its  
DescriptorTable 4-word block is defined as follows:  
Descriptor Word 1 Control Word  
Descriptor Word 2 SA Buffer start address  
Descriptor Word 3 CA Buffer current address  
Descriptor Word 4 MIBA Message Info Buffer addr  
If Descriptor Word 1 is stored at memory address N,  
Descriptor Word 2 is stored at address N+1, and the other  
two words are stored at addresses N+2 and N+3. The first  
To preserve data integrity, the TRXDB bit should be set in  
Control Register 2 to avoid storing incomplete data from  
Number  
of  
Messages  
—————  
Control Word  
Bits 7:4  
CIR2ZN Field  
———————  
Required  
Required  
MIB Space,  
2 Words / Msg  
———————  
Initial MIBAValue,  
Showing the Required  
Leading &Trailing Zeros  
——————————  
(14 address bits)  
Data Space, if  
32 Words / Msg  
———————  
2
4
0010 (2)  
0011 (3)  
0100 (4)  
0101 (5)  
0110 (6)  
0111 (7)  
1000 (8)  
1001 (9)  
1010 (A)  
64  
128  
4
8
0xxxxxxxxxxxx00  
0xxxxxxxxxxx000  
0xxxxxxxxxx0000  
0xxxxxxxxx00000  
0xxxxxxxx000000  
0xxxxxxx0000000  
0xxxxxx00000000  
0xxxxx000000000  
0xxxx0000000000  
8
256  
512  
16  
32  
16  
32  
64  
128  
256  
512  
1,024  
2,048  
4,096  
8,192  
16,384  
64  
128  
256  
512  
1,024  
Table 1. Circular Buffer Mode 2  
Initialization Factors Based on Message Block Size  
HOLT INTEGRATED CIRCUITS  
62  
HI-6120, HI-6121  
CIRCULAR BUFFER MODE 2, Cont.  
messages resulting in error. With TRXDB asserted, the  
host is not bothered by message retries caused by errors.  
The Buffer Empty/Full interrupt (if enabled) is generated  
only upon successful transaction of the entire N-message  
data block.  
The initially-loaded MIB base address value is restricted.  
Some lower bits of the starting address must be zero so the  
device can restore the MIBA pointer to the initial MIB base  
address after the predetermined message count is  
transacted. The required number of logic-0 bits depends  
on the message count. See Table 1. Initializing the MIBA  
base address with more trailing zeros than indicated is  
acceptable; initializing less trailing zeros will cause  
malfunction.  
To initialize Circular Buffer Mode 2, the host must know the  
number of messages to be transacted, always a power of  
two: 1, 2, 4, 8, 16, 32, 64, 128, 256 or 512 messages. The  
host writes descriptor Control Word bits 7:4 with an  
encoded 4-bit value to set the fixed number of messages to  
be transacted. See Table 1. The host initializes the  
descriptor block MIBA pointer with a Message Information  
Buffer starting address. Because the MIB stores two words  
for each message, the allocated MIB space should equal  
2x the number of messages.  
Allocated space in the data buffer (column 3 in Table 1)  
assumes each message has the maximum 32 data words.  
If messages contain less than 32 words, the data buffer  
size can be reduced. Since Circular Buffer Mode 2 counts  
messages, values in all remaining Table 1 columns remain  
valid when message word count is reduced.  
Data Word N  
Time-Tag Word  
Data Word(s)  
Last Message  
in Data Block  
Last Message  
in Data Block  
Message Info Word  
Data Word 1  
Increasing  
Memory  
Address  
Time-Tag Word  
Data Word N  
Data Word(s)  
Current  
Message  
Message Info Word  
MIB Address  
Current Address  
Start Address  
Control Word  
Current  
Message  
Current  
Address  
Data Word 1  
Time-Tag Word  
Message Info Word  
Data Word N  
Data Word(s)  
First Message  
in Data Block  
Descriptor Block  
for Subaddress  
Assigned  
Subaddress  
Message Info Buffer  
(MIB)  
Start  
Address  
Data Word 1  
First Message  
in Data Block  
Assigned  
Subaddress  
Circular  
Memory Address for the Applicable  
Subaddress Block is Derived From  
the Decoded Command Word  
Data Buffer  
Figure 17. Illustration of Circular Buffer Mode 2  
Segregated storage for data and message information simplifies host loading / offloading of buffered data.  
Descriptor MIB Address tracks number of messages. Full count occurs when N initialized 0-bits become N 1-bits.  
When full number of messages in block is transacted, an optional interrupt is generated to notify host.  
HOLT INTEGRATED CIRCUITS  
63  
HI-6120, HI-6121  
CIRCULAR BUFFER MODE 2, Cont.  
The host may read the MIBA value to determine the  
number of messages that have occurred since  
initialization. By reading the initially-zeroed lower bits of  
the MIB Address, the host may determine the number of  
the next occurring message.  
For transmit subaddresses using Circular Buffer Mode 2,  
the device transmits data from the assigned RAM buffer,  
starting at the location specified by the CApointer. The first  
data word transmitted is stored at the location specified by  
the CA pointer. After all data words are transmitted (as  
specified in the command word) the device writes  
Message Information and Time-Tag words in the Message  
Information Buffer then updates the descriptor CA Current  
Address and MIBA Message Information pointers for next-  
message readiness. If the predetermined total number of  
messages has not yet been transacted, MIBA points to the  
next location in the message information buffer and CA  
points to the next location in the data buffer. If the  
completed message is the last message in the block, the  
CA current (data) address and MIBA message Information  
pointers are reinitialized to their base address values.  
(Control Word bits 7:4 tell the device how many MIBAlower  
bits to reset.) If the descriptor Control Word IXEQZ bit is  
asserted (and if the Interrupt Enable Register IXEQZ bit is  
asserted) the device generates a Buffer Full / Empty  
interrupt, asserting the INTMES interrupt output.  
From Table 1, a block of 128 messages requires 8 trailing  
zeros in the initial MIBA address, for example, 0x0F00.  
After each message is completed, the MIBA value is  
updated (0x0F02, 0x0F04, etc.) The device detects  
message block completion when all required initially-zero  
trailing address bits equal 1 after MIBA is incremented  
once. In our example, MIBAwould increment from 0x0FFE  
to 0x0FFF. When “full count” occurs, the device updates  
MIBAto the original value (e.g., 0x0F00) and copies the SA  
starting address value to CA current address register,  
ready for buffer service by the host. The device optionally  
generates a “buffer empty-full” interrupt for the host when  
block transfer is completed.  
During block transfer, the host can read the MIBA value to  
determine the number of additional messages needed  
before the N-message data block is complete.  
Circular Buffer Mode 2 does not support NOTICE2  
segregation of broadcast data, even when the NOTICE2  
bit equals 1 in Configuration Register 1. Data words from  
broadcast receive commands are stored in the same  
buffer with data from non-broadcast receive commands.  
The BCAST bit in the Message Information Word reflects  
broadcast or non-broadcast status for each stored  
message. If broadcast messages to the subaddresss are  
not expected during data block transmission or will result in  
data block error, the host can illegalize broadcast  
commands for the subaddress, either permanently or only  
when block transmission is scheduled.  
Message processing for all commands begins with the RT  
reading the unique descriptor block for the subaddress  
specified by the T/R bit, subaddress and word count fields  
in the received command word.  
For receive subaddresses using Circular Buffer Mode 2,  
the device stores received data words in the circular data  
buffer. The first data word received for each message is  
stored at the location indicated by the CApointer. After the  
correct number of words is received (as specified in the  
command word) the device writes Message Information  
and Time-Tag words in the Message Information Buffer  
then updates the descriptor CACurrentAddress and MIBA  
Message Information pointers for next-message  
readiness. If the predetermined total number of messages  
has not yet been transacted, MIBA points to the next  
location in the message information buffer and CApoints to  
the next location in the data buffer. If the completed  
message is the last message in the block, the CA current  
(data) address and MIBA message Information pointers  
are reinitialized to their base address values. (Control  
Word bits 7:4 tell the device how many MIBA lower bits to  
reset.) If the descriptor Control Word IXEQZ bit is asserted  
(and if the Interrupt Enable Register IXEQZ bit is asserted)  
the device generates a Buffer Full / Empty interrupt,  
asserting the INTMES interrupt output.  
For transmit subaddresses using Circular Buffer Mode 2,  
occurrences of broadcast-transmit commands to RT31 do  
not result in bus transmission. However these messages  
update the Message Information Word addressed by the  
Message information Block (MIB) pointer (and the  
following Time-Tag Word) but afterwards, the MIB and  
CA pointers remain unchanged. The next transmit  
command to the same subaddress, whether broadcast or  
not, overwrites the Message Information and Time-Tag  
Word locations written by the previous broadcast transmit  
command.  
HOLT INTEGRATED CIRCUITS  
64  
HI-6120, HI-6121  
CIRCULAR BUFFER MODE 2, Cont.  
Msg Count increments to 4,  
full count, data block complete.  
Device updates CA to equal  
buffer Start Address 0x0500.  
Device updates MIBA to equal  
MIB Start Address 0x0600.  
IXEQZ interrupt is generated.  
0x057F  
Data Word 32  
Data Words 2-31  
0x0561 - 0x057E  
0x0560  
Receive Message #4  
32 Data Words  
Data Word 1  
Data Word 32  
0x055F  
Msg Count increments to 3.  
Device updates CA to 0x0560  
and updates MIBA to 0x0606.  
Time-Tag Word 4  
Msg Info Word 4  
Time-Tag Word 3  
Msg Info Word 3  
Time-Tag Word 2  
Msg Info Word 2  
Time-Tag Word 1  
Msg Info Word 1  
0x0607  
0x0606  
0x0605  
0x0604  
0x0603  
0x0602  
0x0601  
0x0600  
Data Words 2-31  
0x0541 - 0x055E  
0x0540  
Receive Message #3  
32 Data Words  
Data Word 1  
Data Word 32  
0x053F  
Msg Count increments to 2.  
Device updates CA to 0x0540  
and updates MIBA to 0x0604.  
Data Words 2-31  
0x0521 - 0x053E  
0x0520  
Receive Message #2  
32 Data Words  
Data Word 1  
Data Word 32  
0x051F  
Msg Count increments to 1.  
Device updates CA to 0x0520  
and updates MIBA to 0x0602.  
Data Words 2-31  
0x0501 - 0x051E  
0x0500  
Receive Message #1  
32 Data Words  
Data Word 1  
RAM  
Address  
RAM  
Address  
Message  
Information  
Buffer (MIB)  
Data Word  
Buffer  
MIB Address  
Current Address  
Start Address  
Control Word  
MIB Address = 0x0600  
Current Address = 0x0500 Buffer current address in RAM  
Start address = 0x0500 Buffer start address in RAM  
MIB start address in RAM  
Increasing  
Memory  
Address  
Control Word = 0x8042 Circular Mode 2, 4 messages, IXEQZ Interrupt  
Initialized Descriptor Values  
Descriptor Block  
for a  
Receive Subaddress  
Figure 18. Circular Buffer Mode 2 Example for a Receive Subaddress  
Data Block completion is based on number of messages, not Buffer Full or Buffer Empty.  
Example is set to successfully transact four 32 data word receive messages, then generate IXEQZ interrupt for host.  
The data buffer requires minimal processing by host because message information words are stored separately in MIB.  
HOLT INTEGRATED CIRCUITS  
65  
HI-6120, HI-6121  
MODE COMMAND PROCESSING  
GENERALCONSIDERATIONS  
Note: Mode command MC0 “dynamic bus control”  
cannot be implemented in the device since the HI-6120  
cannot act as a Bus Controller. Therefore, the “dynamic  
bus control acceptance” status bit cannot be set in the  
outgoing status word from this device.  
The device provides decoding for all mode code  
combinations, consistent with MIL-STD-1553B  
requirements. Several mode command options are  
provided to suit any application requirement:  
In Configuration Register 1, the option bit UMCINV  
(Undefined Mode Codes Invalid) globally defines whether  
undefined mode code commands are treated as valid  
(default) or invalid commands. This bit applies only to the  
following 22 mode code commands that are undefined in  
MIL-STD-1553B:  
MODE COMMAND INTERRUPTS  
For mode commands, interrupt generation is programmed  
by the top three bits in the descriptor table Control Word.  
Notice that broadcast-transmit interrupts can be enabled  
for mode code values in the range of 0 - 15, but broadcast-  
transmit mode codes 16 - 31 are not allowed. When a  
mode command is received and the IWA interrupt bit is  
asserted in its descriptor Control Word, that command will  
generate a host interrupt if the IWA bit is high in the  
Interrupt Enable Register. The IWA bit is asserted in the  
Pending Interrupt Register and the INTMES interrupt  
output is asserted.  
Mode Codes 0 through 15 with T/R bit = 0  
Mode Codes16, 18 and19 withT/R bit = 0  
Mode Codes 17, 20 and 21 with T/R bit = 1  
If the UMCINV bit is low (default after MR reset) undefined  
mode code commands are considered valid and RT  
response is based on individual mode command settings  
in the Illegalization Table: If the command’s table bit equals  
0, the mode command is legal; the RT responds “in form”  
and updates status. If the command’s table bit equals 1 the  
mode command is illegal, the RT asserts Message Error  
status and (if non-broadcast) transmits only its Status  
Word without associated data word. The table below  
describes explicit terminal response for each mode code  
value and command T/R bit state, based on various option  
settings.  
Before INTMES interrupt assertion, the device updates the  
Interrupt Log buffer, writing a new IIW Interrupt Information  
Word and a new IAW Interrupt Address Word. The IWA  
(interrupt when accessed) bit is asserted in the new IIW to  
indicate interrupt type. The IAW contains the Descriptor  
Table address for the mode command’s Control Word,  
based on mode code value and command word T/R bit  
state. The host reads the IAW to determine the command  
that caused the interrupt.  
MODE COMMAND DATAWORDS  
If UMCINV is asserted, the 22 undefined mode code  
commands are treated as invalid: There is no terminal  
recognition of the command. No command response  
occurs and status remains unchanged for the benefit of  
following “transmit status” or “transmit last command”  
mode commands.  
Mode commands having mode code values from 0 through  
15 (decimal) do not have an associated data word. These  
are received as Command Word only, never having a  
contiguous data word. The terminal response to valid  
mode commands 0-15 always consists of Status Word  
only, assuming command was not broadcast.  
If UMCINV is low, the device determines legal vs. illegal  
status of commands from the Illegalization Table. If the  
terminal does not use illegal command detection, the  
Illegalization Table should be left in its post-reset default  
state, all values equal logic 0. In this case, the terminal  
provides “in form” response to all valid commands. The  
terminal responds with clear status and a transmitted  
mode data word for mode commands 16-31 with T/R bit  
equals 1. Assigned data buffer locations can be initialized  
to provide predictable “in form” responses for all transmit  
mode codes 16-31. (If UMCINV is asserted, the terminal  
will not respond or update status for received mode codes  
17, 20 and 21 with T/R = 1.)  
Mode commands having mode code values from 16  
through 31 (decimal) always have an associated data  
word. When the command word T/R bit equals 0, the  
terminal receives a data word, contiguously following the  
Command Word. When valid legal mode commands 16-  
31 arrive with T/R bit equal to 1, the terminal responds by  
transmitting its status word with a single data word.  
When the SMCP option bit in Configuration register 1 is  
zero, individual data words for mode codes 16-31 decimal  
are stored in an indexed or ping-pong buffer assigned by  
the mode command’s Descriptor Table entry. Circular  
buffer methods are not available for mode code  
commands.  
To use illegal command detection, the host modifies the  
Illegalization Table to make illegal any combination  
subaddress and mode code commands. This may include  
undefined mode codes, reserved mode codes, and/or  
mode codes not implemented in the application.  
When the SMCP option bit in Configuration register 1 is  
asserted, individual data words for mode codes 16-31  
decimal are stored within the Descriptor Table itself. This is  
explained next.  
HOLT INTEGRATED CIRCUITS  
66  
HI-6120, HI-6121  
MODE COMMAND PROCESSING, Cont.  
MODE CODE COMMAND SUMMARY  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Command  
T/R Bit  
Mode Code  
Binary Dec.  
MIL-STD-1553B  
Defined Function  
Associated  
Data Word  
Broadcast  
Allowed  
See  
Note  
0
00000  
to  
01111  
0
to  
15  
Undefined Mode Commands 0 -15  
with T/R bit equal to 0  
No  
No  
(1)  
1
1
1
1
1
1
1
1
1
00000  
00001  
00010  
00011  
00100  
00101  
00110  
00111  
01000  
0
1
2
3
4
5
6
7
8
Dynamic Bus Control  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Synchronize (without data)  
Transmit Status Word  
Initiate Self-Test  
Transmitter Shutdown  
Override Transmitter Shutdown  
Inhibit Terminal Flag  
Override Inhibit Terminal Flag  
Reset Remote Terminal  
1
01001  
to  
01111  
9
to  
15  
Reserved Mode Commands 9 - 15  
with T/R bit equal to 1  
No  
Yes  
(2)  
(1)  
0
1
10000  
10000  
16  
16  
Undefined Mode Command  
Transmit Vector Word  
Yes  
Yes  
No  
No  
0
1
10001  
10001  
17  
17  
Synchronize With Data  
Undefined Mode Command  
Yes  
Yes  
Yes  
No  
(1)  
(1)  
0
1
10010  
10010  
18  
18  
Undefined Mode Command  
Transmit Last Command  
Yes  
Yes  
No  
No  
0
1
10011  
10011  
19  
19  
Undefined Mode Command  
Transmit Built-In Test Word  
Yes  
Yes  
No  
No  
(1)  
(1)  
0
1
10100  
10100  
20  
20  
Selected Transmitter Shutdown  
Undefined Mode Command  
Yes  
Yes  
Yes  
No  
0
1
10101  
10101  
21  
21  
Override Selected Transmitter Shutdown  
Undefined Mode Command  
Yes  
Yes  
Yes  
No  
(1)  
(2)  
0
01001  
to  
01111  
22  
to  
31  
Reserved Mode Commands 22 - 31  
with T/R bit equal to 0  
Yes  
Yes  
1
01001  
to  
01111  
22  
to  
31  
Reserved Mode Commands 22 - 31  
with T/R bit equal to 1  
Yes  
No  
(2)  
(1) The 22 undefined mode commands can be rendered invalid by setting the UMCINV (undefined mode codes invalid) option bit in  
Configuration Register1. If UMCINV is asserted, there is no recognition of the undefined command by the terminal. If UMCINV is zero,  
the commands are considered valid. Terminal response when UMCINV equals 0 is wholly determined by the Illegalization Table:  
a) If a command’s bit in the Illegalization Table equals zero, the terminal responds “in form” with Clear Status. Mode commands  
17, 20 and 21 are undefined when T/R bit equals one, but will transmit a contiguous data word. Mode commands 16, 18 or 19 are  
undefined when T/R bit equals 0, but will receive a contiguous data word.  
b) If a command’s bit in the Illegalization Table equals one, the command is considered illegal. The Message Error (ME) status bit  
is asserted and the terminal transmits status without data word. Illegal mode commands 16-31 will not transmit or receive a mode  
data word.  
(2) Response to the reserved mode commands is fully defined by Illegalization Table settings. As described in (a) and (b) above, the  
terminal illegalizes any reserved mode command having Illegalization Table bit equal to 1, and responds “in form” when the Table bit  
equals zero. The “in form” response for reserved mode commands 16 through 31 transacts a received or transmitted data word.  
HOLT INTEGRATED CIRCUITS  
67  
HI-6120, HI-6121  
MODE COMMAND PROCESSING, Cont.  
STANDARD MODE COMMAND PROCESSING  
Data buffer options for mode commands differ from buffer  
options for subaddress commands. Mode commands can  
use ping-pong buffering or indexed buffering. When mode  
commands use indexed buffers, “single message mode”  
(INDX = 0) is recommended. When using indexed or ping-  
pong buffers for mode commands:  
When SMCP is enabled, the host need not initialize the  
mode code command segments in the Descriptor  
Table. When Simplified Mode Command Processing is  
selected, the host does not write Descriptor Words 2-3 in  
the Descriptor Table entries for mode commands. For  
mode code values 0 to 15 decimal, the Descriptor Word 4  
serves no function because these mode codes do not have  
an associated data word. For transmit mode code values  
16 to 31, the host may initialize Descriptor Word 4. The  
default transmit value is 0x0000. Mode command MC16  
“transmit vector word” is one of the three defined mode  
commands that transmit a data word: MC16, MC18 and  
MC19. Its Descriptor Word 4 should be initialized if a value  
other than 0x0000 is needed. MC18 and MC19 are  
discussed below.  
For mode commands without associated data word  
(mode codes 0-15 decimal), only the Message  
Information and Time-Tag words are updated in the  
mode command’s assigned data buffer in RAM.  
For mode commands 16-31 (decimal) that receive a  
data word, indexed and ping-pong buffer methods  
copy the received mode data word to the mode  
command’s assigned data buffer in shared RAM, after  
the message is transacted. The Message Information  
andTime-Tag words are also updated.  
For mode commands without associated data word  
(mode codes 0-15 decimal), Simplified Mode  
Command Processing updates the Message  
Information and Time-Tag words in Descriptor Words 2  
and 3, and Descriptor Word 1 (bits 9,11). For these  
commands, SMCP does not update Descriptor Word  
4, which may be non-zero if written earlier by the host.  
For most mode commands 16-31 (decimal) that  
transmit a data word, the device reads the data word  
for transmit from the buffer location assigned in the  
Descriptor Table. Exceptions occur for MC18 “transmit  
last command” and for MC19 “transmit BIT word.” The  
MC18 data word is automatically provided by the  
device, based on recent command transactions. The  
MC19 data word comes from register 0x14 or 0x15,  
depending on the state of the ALTBITW option in  
Configuration Register 2. For both MC18 and MC19,  
the transmitted data word is automatically recorded in  
the mode command’s assigned data buffer in RAM,  
after message completion. The Message Information  
andTime-Tag words are also updated.  
For receive mode commands 16-31 (decimal) that  
receive a data word, Simplified Mode Command  
Processing copies the received mode data word to  
Descriptor Word 4. The Message Information and  
Time-Tag words in Descriptor Words 2 and 3, and  
Descriptor Word 1 (bits 9, 11) are also updated.  
For most transmit mode codes 16-31 (decimal), the  
device reads the data word for transmission from each  
command’s Descriptor Word 4. Exceptions occur for  
MC18 “transmit last command” and for MC19 “transmit  
built-in test word”. The MC18 data word is  
automatically provided, based on the last command  
transacted. The MC19 data word comes from register  
0x14 or 0x15, depending on the state of the ALTBITW  
option in Configuration Register 2. For MC18 and  
MC19, the transmitted data value is automatically  
copied to the mode command’s Descriptor Word 4  
after message completion. The Message Information  
and Time-Tag words in Descriptor Words 2 and 3, and  
Descriptor Word 1 (bits 9, 11) are also updated.  
SIMPLIFIED MODE COMMAND PROCESSING  
Mode commands have a buffer alternative that is  
unavailable for subaddress commands. The SMCP bit in  
Configuration Register 1 selects Simplified Mode  
Command Processing, a global option applying to all  
mode commands. When the SMCP bit is high, mode  
command descriptor blocks (in the Descriptor Table) do  
not contain data pointers to reserved buffers elsewhere in  
the shared RAM. Instead, each 4-word descriptor block  
itself contains the message information word, the time-tag  
word and the data from the most recent occurrence of each  
mode command:  
————————————  
Table 3 shows terminal response to all possible  
subaddress and mode code command combinations. The  
table summarizes terminal response for the full range of  
message conditions, including errors, incomplete  
messages, etc. The table explicitly describes terminal  
response and impact on terminal Status Word, Descriptor  
Control Words and data buffer Message Information  
Words. The table includes effects for all pertinent setup  
options and identifies all interrupt options available. Bold  
text blocks indicate error-free messages or “in form” Clear  
Status responses when the terminal is not using “illegal  
command detection”.  
Descriptor Word 1 Mode command Control Word.  
Descriptor Word 2 Message Information Word.  
Descriptor Word 3 Time-Tag Word.  
Descriptor Word 4 Mode Data Word.  
Descriptor Word 1 contains the receive or transmit mode  
command Control Word. When SMCP is used, just two  
Control Word bits are used: DBAC (descriptor block  
accessed) and BCAST(broadcast).  
HOLT INTEGRATED CIRCUITS  
68  
HI-6120, HI-6121  
INTERRUPT MANAGEMENT  
HOST MESSAGE DETECTION OPTIONS  
Upon receiving messages, the host has several options.  
Separate interrupt outputs are provided for hardware  
interrupts (INTHW) and message interrupts (INTMES).  
The host programs both pins as either pulsed interrupt  
outputs or level-sensitive outputs, by writing the INTSELbit  
in Configuration Register 1:  
The individual descriptor table Control Words have enable  
flags for generating interrupts. Interrupts can be enabled  
on a subaddress or mode code basis. For any subaddress,  
interrupts can be enabled for (a) every command  
occurrence, (b) upon occurrence of broadcast commands,  
(c) at end of multiple message block transfers (index mode  
or circular buffer modes only), or (d) no interrupts at all.  
Config.  
Register 1  
Bit  
Interrupt  
Output  
Pins  
Interrupt  
Acknowledge  
Input Pins  
INTHW  
INTMES  
ACKHW  
ACKMES  
INTSEL  
0
Some subaddress commands may not require immediate  
host servicing. If the number of legal subaddresses is  
small, the host can poll descriptor table Control Words for  
the legal subaddresses to detect message activity. The  
Control Word’s DBAC bit (descriptor block accessed) is set  
whenever a message is processed. This bit is  
automatically reset by any host read cycle to the descriptor  
Control Word. Whenever the DBAC bit reads high, the  
subaddress transacted a message since the last Control  
Word read cycle.  
Pulse Output  
Active Low  
TheACK pins  
are not used.  
1
Level Output  
Active Low  
Active High  
(internal pull-downs)  
Pulsed outputs have brief (~250ns) duration, sufficient to  
drive edge-triggered host inputs. In the level mode of  
operation, asserted interrupts remain low until  
acknowledged by the host. There are two ways the host  
can acknowledge level interrupts: (1) assert theACKHW or  
ACKMES input pin to clear the respective interrupt INTHW  
or INTMES output, or (2) read the Pending Interrupt  
Register to clear both INTHW and INTMES output pins to  
the high state.  
Another interrupt alternative that works for any number of  
legal subaddresses (or when illegal command detection is  
not used) is to poll the device ACTIVE pin. This pin is high  
whenever a command is being processed. After the  
ACTIVE pin goes low, the host can read the Current  
Command Register to determine the processed command  
word, or may fetch the command's descriptor table  
address from the Current Control Word Address register.  
Both registers maintain their loaded values until the next  
valid command to the terminal is decoded.  
Assertion of the INTHW interrupt indicates an interrupt-  
causing hardware event that is enabled in the Interrupt  
Enable Register. Defined interrupt-causing events are  
listed in the table on the following page. When the INTHW  
output is asserted, one or more bits are set in the Pending  
Interrupt Register, to identify the interrrupt event(s).  
Assertion of the INTMES interrupt after a message is  
completed indicates a predetermined message event  
occurred that is (1) globally enabled in the Interrupt Enable  
Register and (2) specifically enabled for the last command  
transacted. The Descriptor Table Control Word for each  
command is programmed by the host to enable events that  
generate message interrupts. The type of INTMES event is  
reflected in the IXEQZ, IWA, IBR, ILCMD and MERR bits  
within the Pending Interrupt Register.  
HOST INTERRUPT GENERATION  
Interrupts are output signals notifying the host when  
predetermined events have occurred during terminal  
operation; the interrupt-causing events are fully  
programmable. The host defines message-specific  
interrupt-causing events when initializing the Descriptor  
Table. Other hardware-based interrupts are configured  
when internal device registers are initialized.  
The interrupt architecture maintains information for the last  
16 interrupts in a 32-word ring buffer. The device  
automatically handles interrupt-logging overhead. Each  
interrupt generates two words of information to help the  
host perform interrupt processing. The Interrupt  
Identification Word (IIW) identifies the type(s) of interrupt  
that occurred. The Interrupt Address Word (IAW) identifies  
the interrupt source (e.g., subaddress Descriptor Block)  
using a 16-bit address.  
To manage host interrupts, the device architecture  
involves an Interrupt Log buffer, three control registers, two  
interrupt output pins and two interrupt acknowledge input  
pins. The three internal registers are the Pending Interrupt  
Register, the Interrupt Enable Register and the Interrupt  
Log Address Register. The Pending Interrupt Register  
contains information identifying events programmed by  
the host to generate interrupts. The Interrupt Enable  
register lets the host enable or disable interrupt generation  
for different interrupt-causing events. The Interrupt Log  
Buffer is a 32-word ring buffer located in shared RAM  
address range 0x0040 to 0x005F.  
HOLT INTEGRATED CIRCUITS  
69  
HI-6120, HI-6121  
INTERRUPT MANAGEMENT, Cont.  
INTERRUPT LOGADDRESS REGISTER  
IIW - Interrupt Identification Word  
IAW - Interrupt  
Address Word  
Bits 7:0 in this register indicate the IIW storage address  
within the buffer for the next occurring interrupt, 0x0040 to  
0x005E. Bits 15:8 indicate the number of interrupts since  
the register was last read. For further details, see the full  
description of the Interrupt LogAddress Register.  
Bit  
15  
14  
13  
12  
11  
10  
9
Interrupt  
IXEQZ  
IWA  
IBRD  
——  
——  
MERR  
——  
ILCMD  
Origin  
Message  
Message  
Message  
——  
IAW contains the  
Command Word  
DescriptorTable  
Address  
——  
INTERRUPTADDRESS WORD (IAW)  
Message  
——  
Message  
Stored in the Interrupt Log Buffer, InterruptAddress Words  
(IAW) identify interrupt-causing messages by storing the  
descriptor block address for the subaddress or mode code  
command that generated each message interrupt.  
8
————————————————————  
7
6
5
4
3
2
1
0
SPIFAIL  
LBFA  
LBFB  
TTINT1  
TTINT0  
RTAPF  
EECKF  
RAMIF  
Hardware  
Hardware  
Hardware  
Hardware  
Hardware  
Hardware  
Hardware  
Hardware  
INTERRUPT IDENTIFICATION WORD (IIW)  
Stored in the Interrupt Log Buffer, Interrupt Identification  
Words identify type of interrupt event. Bit assignments  
match those used in the Pending Interrupt Register. The  
host or subsystem reads the IIW to determine which type of  
interrupt occurred. The Interrupt Identification Word is  
defined as follows:  
IAW contains  
0x0000  
RESET AND INITIALIZATION  
This section describes the hardware and software reset  
mechanisms. Hardware Master Reset returns the device  
to the uninitialized state, requiring register/RAM  
initialization before terminal execution can begin.  
Initialization can be performed by the host after MR reset,  
or automatically, at the user’s option, by reading  
configuration data from an external serial EEPROM.  
Software reset is asserted by setting the SRST bit in  
Configuration Register 1. Software reset has minimal  
effect on previously initialized registers and RAM  
structures that define terminal behavior. However some  
reinitialization may be needed for some applications, after  
SRSTreset is complete.  
assertion, a host read cycle to any address returns the  
value in the Operational Status register.  
2. If the MTSTOFF pin is logic zero, the device performs a  
memory test (< 985us). If memory error occurs, the BMTF  
bit is set in the BIT Word Register 0x0014. If the MTSTOFF  
pin is logic one, the memory test is bypassed. This option  
might be chosen if a faster reset process is needed.  
Regardless of MTSTOFF state, all RAM locations above  
address 0x001F are cleared to 0x0000.  
3. After internal processes are initialized, the device  
checks the latched state of the AUTOEN bit in the  
Operational Status register:  
MASTER RESET USING THE MR PIN  
AND OPTIONALAUTO-INITIALIZATION  
If the Operational Status register AUTOEN bit reads  
low, auto-initialization is bypassed. The host must initialize  
the terminal:  
Hardware master reset is initiated by a low to high  
transition on the MR pin; it should be applied after power-  
up, but may be used anytime afterward. When asserted,  
the MR input pin causes immediate, unconditional  
hardware reset. Command processing is terminated, the  
bus decoders and encoder are cleared, the Time-Tag  
count is reset. The Message Error, Busy and Broadcast  
Command Received status bits are reset and Terminal  
Flag bit is enabled for assertion.All internal logic is cleared.  
Registers and RAM structures are restored to the states  
shown in Figure 19. The READY, ACTIVE, INTMES and  
INTHW output pins are negated if previously asserted.  
A) The device asserts the READY output pin. This  
state change indicates the host can begin post-MR  
reset initialization of registers and RAM structures.  
B) Upon READY assertion, the host should initialize  
configuration and option registers, the Descriptor  
Table(s) and the Illegalization Table. Initialization may  
include data written into the various transmit  
subaddress buffers assigned by the initialized  
DescriptorTable.  
After MR pin low to high transition, these steps occur:  
C)  
After the host completes initialization, it must  
1. After 200ns, the states of the following input pins are  
latched into the Operational Status register: RTA4-RTA0,  
RTAP, AUTOEN, LOCK and INTSEL. Before READY  
assert the STEX (start execution) bit in Configuration  
Register 1 to begin RemoteTerminal operation.  
HOLT INTEGRATED CIRCUITS  
70  
HI-6120, HI-6121  
RESET AND INITIALIZATION, Cont.  
Hex  
Address  
ContentsAfter  
MR Reset  
ContentsAfter  
SRST Reset  
Device Register  
0x0000  
0x0001  
0x0002  
Configuration Register 1  
Configuration Register 2  
Operational Status Register  
0x0000  
0x0000  
bits 7:0 reset to 0x00  
bits 15:8 match pins  
0x0000  
no change  
no change  
no change  
0x0003  
0x0004  
0x0005  
0x0006  
0x0007  
0x0008  
0x0009  
0x000A  
Current Command Register  
Current Control WordAddress Register  
DescriptorTable BaseAddress Register  
Pending Interrupt Register  
1553 Status Word Bits Register  
Time-Tag Register  
Interrupt LogAddress Register  
Current Message Information Word Register  
Reserved  
MemoryAddress Pointer (HI-6121 Only)  
Interrupt Enable Register  
Time-Tag Utility Register  
BusASelect Register  
Bus B Select Register  
no change  
no change  
0x0200  
no change  
0x0000  
0x0000  
no change  
no change  
no change  
no change  
no change  
no change  
no change  
no change  
0x0000  
0x0000  
0x0200  
0x0000  
0x0000  
0x0000  
0x0040  
0x0000  
0x0000  
0x0000  
0x0007  
0x0000  
0x0000  
0x0000  
See Note 1  
0x0000  
0x0000  
0x0000  
0x0000  
0x000B-0x000E  
0x000F  
0x0010  
0x0011  
0x0012  
0x0013  
0x0014  
0x0015  
0x0016  
0x0017  
0x0018  
Built-InTest (BIT) Word Register  
Alternate BITWord Register  
Test Control Register  
no change  
0x0000  
0x0000  
0x0000  
0x0000  
no change  
BISTControl Register  
LoopbackTestTransmit Data Register  
LoopbackTest Receive Data Register  
Reserved  
0x0019  
0x0020-0x001F  
0x0000  
0x0000  
Hex  
Address  
ContentsAfter  
MR Reset  
ContentsAfter  
SRST Reset  
RAM Structure  
0x0020-0x003F  
0x0040-0x005F  
0x0060-0x00FF  
0x0100-0x01FF  
0x0200-0x03FF  
0x0400-0x7FFF  
Temporary Receive Data Buffer, 32 Words  
Interrupt Log Buffer, 32 Words  
Unallocated RAM, 160 Words  
Illegalization Table, 256 Words  
DescriptorTable (Primary), 512 Words  
Host-Assigned Data Buffers  
all 0x0000  
all 0x0000  
all 0x0000  
all 0x0000  
all 0x0000  
all 0x0000  
all 0x0000  
no change  
no change  
no change  
no change  
See Note 2  
no change  
no change  
Secondary DescriptorTables, if used  
StateAfter  
MR Reset  
StateAfter  
SRST Reset  
Terminal Function  
Hardware Bus Decoders  
reset  
reset  
reset  
reset  
reset  
reset  
Hardware Encoders andTransmitters  
Command Processing &ACTIVE Output  
Terminal Status (incl ME & BCR bits)  
Prior Bus Shutdown by Mode Cmd MC4 or MC20  
PriorTerminal Flag Inhibit by Mode Cmd MC6  
READYOutput  
reset  
reset  
overridden  
overridden  
reset  
overridden  
overridden  
set  
INTMES & INTHW Interrupt Outputs  
negated (high)  
negated (high)  
Notes:  
1. After Master Reset, bits 15, 14 and 2 in the BIT Word Register depend on input pin settings. See register description. If the  
MTSTOFF input pin is low, register bit 3 (BMTF) depends on memory test outcome. The remaining bits are unconditionally  
reset. However if auto-initialization is enabled and EEPROM load failure occurs during the subsequent initialization process,  
register bit 1 (EELF) will be set.  
2. Upon SRST reset, the DBAC, DPB, MKBUSY and BCAST bits are reset for each of the 128 Control Words in the primary  
Descriptor Table which starts at address 0x0200. If secondary Descriptor Tables are used (above address 0x0400), the host  
must perform any necessary table reconfiguration after SRSTreset.  
FIGURE 19. Summary of Changes Due to MR Master Reset or SRST Software Reset  
HOLT INTEGRATED CIRCUITS  
71  
HI-6120, HI-6121  
RESET AND INITIALIZATION, Cont.  
If the Operational Status register AUTOEN bit reads  
high, the device initializes itself from an external serial  
EEPROM via the dedicated EEPROM SPI port:  
When the device completes auto-initialization, the  
READYoutput pin is asserted to the high state.  
If an initialization error occurred, these events take  
place immediately after READY assertion: (1) the  
INTHW interrupt output pin is asserted. (2) the  
Operational Status Register 0x0002 is written to  
indicate the type of error. The EECKF or RAMIF bit is  
set to show checksum failure or read-back data  
mismatch between RAM and EEPROM. (3) The  
EELF bit is set in the Built-In Test Word Register  
0x0014. (4) If RAMIF read-back error occurred, the  
address of the first occurring instance is written to  
register address 0x001F. Additional locations beyond  
the saved address may have mismatch, but only the  
first instance is logged.  
The READY output pin remains low while automatic  
self-initialization proceeds. The device reads  
initialization data from the external serial EEPROM  
memory, using the dedicated EEPROM SPI port.  
Initialization includes all registers, all tables (including  
secondary Descriptor Tables, if used) and can include  
initial data written to transmit subaddress data buffers  
allocated by the DescriptorTable.  
If the EE1K pin is low, initialization covers the full  
32K address range 0x0 to 0x7FFF, including the  
entire RAM. Therefore it can initialize secondary  
Descriptor Tables and transmit subaddress  
buffers in the upper RAM space.  
The STEX bit in Configuration Register 1 is still zero.  
If the EE1K pin is high, initialization covers just  
the 1K address range 0x0 to 0x003F. This covers  
all registers and the minimum set of required  
tables, including the primary Descriptor Table from  
0x00200 to 0x003FF. For many applications, this  
is the only DescriptorTable.  
If the STEX bit in the initialization EEPROM is high,  
and if the EECKF, RAMIF and RTAPF bits are reset in  
the Operational Status Register 0x0002, the device  
now sets the STEX bit to start Remote Terminal  
operation. This means: (1) auto-initialization was  
error-free and (2) the RT address in Operational  
Status Register bits 15-10 has correct parity. The  
register’s terminal address bits reflect input pin states  
if the LOCK pin is high, or were overwritten by values  
from the initialization EEPROM, if the LOCK pin is low.  
During auto-initialization, the written value for each  
register or RAM location is read back for confirmation.  
If the read-back value does not match the  
corresponding value from EEPROM, an initialization  
error is saved. This error results in action (described  
below) that occurs when the initialization process is  
finished.  
If automatic STEX assertion was blocked because  
EECKF or RAMIF bits were written high after READY  
assertion, the host can write STEX high, overriding the  
error condition. If STEX assertion was blocked  
because of RT address parity error, the STEX bit  
cannot be asserted until the parity error is corrected.  
The host may overwrite the Operational Status  
Register RTAP4-0 and RTAP bits to correct the error,  
then assert the STEX bit in Configuration Register 1.  
While performing initialization, a running checksum is  
tallied as follows, using EEPROM data read from the  
1K or 32K address range. A properly configured serial  
EEPROM contains a 16-bit checksum value stored at  
the pair of EEPROM locations corresponding to RAM  
address 0x0020. The stored checksum is tallied as if  
RAM address 0x0020 equals 0x0000 and five  
registers are excluded from checksum computation:  
Operational Status register 0x0002, Pending Interrupt  
register 0x0006, Time-Tag register 0x0008 and BIT  
Word register 0x0014. The stored value is actually the  
twos-complement of the 16-bit memory checksum,  
(CHECKSUM + 1).  
If the STEX bit in the initialization EEPROM is low,  
the STEX bit in Configuration Register 1 is not  
asserted at this time. The device awaits STEX  
assertion by a host write to Configuration Register 1  
before starting Remote Terminal operation. The STEX  
bit may be written any time after the READY output pin  
goes high.  
During initialization, byte pairs are sequentially read  
from EEPROM, then merged to a 16-bit value that is  
both written to device RAM (or register) and added  
(running tally) to the twos-complemented checksum  
value. When the full 1K or 32K EEPROM range is  
tallied, the running checksum tally should equal zero,  
indicating error-free checksum tally. After initialization  
(at READY assertion), the 16-bit twos-complement  
checksum value is copied from EEPROM to device  
RAM address 0x0020. This is part of the Temporary  
Receive Data Buffer, which does not interfere with  
terminal initialization.  
After any MR master reset, the state of certain input  
pins (AUTOEN, LOCK and terminal address pins  
RTA4 to RTA0 and RTAP) are latched into Operational  
Status Register 0x0002. Because auto-initialization  
follows master reset, the mirrored pin states may be  
overwritten by the values stored in the initialization  
EEPROM bytes corresponding to register address  
0x0002, only if the LOCK input pin is low.  
A method for programming the EEPROM itself from a fully  
configured terminal is explained in a following section  
entitled “Serial EEPROM Programming Utility”. If a  
HOLT INTEGRATED CIRCUITS  
72  
HI-6120, HI-6121  
RESET AND INITIALIZATION, Cont.  
different method is used for writing the serial EEPROM, the  
twos-complemented checksum (described earlier) must  
be saved in EEPROM locations corresponding to device  
RAM address 0x0020.  
command MC6, inhibit is cleared: The Terminal Flag  
status bit will be transmitted whenever bit 0 is set in the  
1553 Status Word Bits Register.  
4. All 128 descriptor table Control Words are modified  
to reset the DBAC, DPB, MKBUSY and BCAST bits.  
Subaddresses or mode codes using ping-pong or  
single message index mode (INDX = 0) are ready for  
immediate operation after SRST reset is complete.  
However the device cannot reinitialize the Descriptor  
Table to restore multi-message block transfers, for  
indexed buffer mode when initial INDX value was non-  
zero, or for either circular buffer mode.  
Acompatible serial EEPROM uses a SPI interface for byte-  
access read and write operations. Sixteen-bit register and  
RAM values in the HI-612X are stored as upper and lower  
bytes in the EEPROM, in “big endian” fashion. For  
example, the upper byte for register address 0x0000 is  
stored at EEPROM address 0x0000 while the lower byte is  
stored at EEPROM address 0x0001.A64K x 8 EEPROM is  
required to store the entire 32K x 16 address range.  
Serial EEPROM data mapping follows the device memory  
map shown in Figure 1. The single exception: two  
EEPROM locations corresponding to device RAM address  
0x0020 must contain the expected checksum value. The  
serial EEPROM used for auto-initialization should be fully  
written to cover the HI-6120/21 upper address limit of  
0x7FFF (or 0x03FF, depending on the state of the EE1K  
input pin). Ideally the EEPROM image will reflect a post-  
MR reset followed by fresh initialization with nothing  
written to reset-cleared registers or RAM as a result of  
command processing.  
5. The device asserts the READY output pin. Terminal  
operation automatically resumes if the STEX bit in  
Configuration Register 1 was set before SRST  
occurred.  
6. After READY assertion, the host may reset STEX,  
then reinitialize all or part of the Descriptor Table. The  
host can reinitialize the Descriptor Table for  
subaddresses using multi-message block transfers  
(Circular Buffer Mode 1, Circular Buffer Mode 2 or  
Indexed Buffer Mode with initial non-zero INDX.) The  
host can also reinitialize transmit data in the assigned  
transmit subaddress data buffers. Data buffers in RAM  
contain data values loaded before SRST occurred.  
The host can clear or overwrite this old data. The host  
can then assert the STEX bit in Configuration Register  
1 to restart terminal operation.  
SOFTWARE RESET  
Software reset is initiated by a host write that sets the  
SRST bit in Configuration Register 1. This bit is set  
automatically when a “Reset Remote Terminal” mode  
command is received while the MCOPT0 bit is set in  
Configuration Register 2 (0x0002). Software reset causes  
immediate reset without overwriting registers or tables that  
were initialized by the host to define terminal behavior.  
Changes to registers and RAM are summarized in Figure  
19. Software reset cannot initiate automatic self-  
initialization from serial EEPROM. Once the SRST bit in  
Configuration Register 1 is asserted, the following steps  
are performed:  
RESET REMOTE TERMINALMODE CODE  
Mode code MC8 with T/R bit = 1 should reset the Remote  
Terminal. After Status Word transmission, the device  
automatically resets the status Message Error (ME) and  
Broadcast Command received (BCR) bits in its internal  
status register. Bits 0, 14 and 15 are reset in the BIT Word  
register at address 0x0014. If either transmitter was  
shutdown by a previous mode code MC4 or MC20, the  
shutdown condition is overridden. If the Terminal Flag (TF)  
status bit was inhibited, the inhibit is reset. This command  
does not reset any of the host-programmed registers that  
configure the terminal for operation.  
1. The READY, ACTIVE, INTMES and INTHW output  
pins are negated. Terminal execution stops while  
SRST reset is underway. Command processing is  
terminated. The hardware bus decoders and  
hardware encoder are cleared. The Message Error  
and Broadcast Command Received flags in the  
internal status register used for MC2 or MC18 mode  
command responses are not affected by SRST.  
To complete the reset process, the host must assert either  
MR master reset (with or without auto-initialization) or  
assert the SRST bit in Configuration Register 1 to execute  
software reset. Since MC8 requires host interaction, most  
applications will probably utilize the IWA interrupt to alert  
the host when valid MC8 is received.  
2. The Descriptor Base Address register (0x0005) is  
reinitialized to the base address 0x0200. The following  
registers are cleared: the 1553 Status Word Bits  
register (0x0007), the Time-Tag register (0x0008) and  
test registers 0x0016 to 0x0019.  
Per MIL-STD-1553B appendix 30.4.3, any reset initiated  
by the “Reset Remote Terminal” mode command should  
be completed within 5 ms following transmission of the  
Status Word. Overall reset time includes internal device  
initialization, either host initialization or auto-initialization.  
Overall time to complete reset initiated by the “Reset  
Remote Terminal” mode command MC8 is affected by host  
response speed and application complexity.  
3. The BIT Word Register (0x0014) is cleared, except  
the contained RTAPF bit is not changed. This  
reinstates any bus previously shutdown by mode code  
commands MC4 or MC20 (decimal). If the Terminal  
Flag status bit was previously inhibited by mode  
HOLT INTEGRATED CIRCUITS  
73  
HI-6120, HI-6121  
RESET AND INITIALIZATION, Cont.  
SERIALEEPROM PROGRAMMING UTILITY  
The HI-6120 or HI-6121 can program a serial EEPROM via  
the dedicated EEPROM SPI port for subsequent auto-  
initialization events. The device copies host-configured  
registers and RAM (configuration tables and possibly data  
buffers) to serial EEPROM.  
the programmed state for the STEX bit in  
Configuration Register 1.  
If auto-initialize should program Configuration  
Register 1 STEX bit to logic 0, RAM address  
0x0020 is first written 0xA5F0, then a second load  
to 0x0020 overwrites the value just written with  
0x5F0A.  
Compatible SPI serial EEPROMs are 3.3V, operate in SPI  
modes 1 or 3 and and have 128-byte pages. The serial SPI  
data is clocked at 8.3 MHz SCK frequency. A 2K x 8  
EEPROM can restore the lower 1K x 16 device address  
space. A64K x 8 EEPROM can restore the entire 32K x 16  
device address space.  
If auto-initialize should program Configuration  
Register 1 STEX bit to logic 1, RAM address  
0x0020 is first written 0x5A0F, then a second load  
to 0x0020 overwrites the value just written with  
0xA0F5.  
A deliberate series of events initiates copy of data from HI-  
6120 or HI-6121 to serial EEPROM. This reduces the  
likelihood of accidental EEPROM overwrites. This series  
of events must occur to initiate programming:  
In either case, the two unlock writes must occur  
without intervening access to other device addresses,  
except MemoryAddress Pointer 0x000F for HI-6121.  
1A. If using a fresh host initialization immediately  
following MR master reset as the basis for  
EEPROM copy: With the AUTOEN, TXINHA and  
TXINHB pins in logic zero state, apply MR master  
reset and wait for READY output assertion. Verify that  
the INTHW output does not pulse low at READY  
assertion, indicating likely RT address parity error at  
the RTA4:0 and RTAP pins. Using known good  
parameters, the host initializes device registers, the  
RAM descriptor table and transmit data buffers (if  
necessary). Do not assert STEX. Go to step 2.  
or  
4. The EECOPY input pin is driven high for at least 1  
ms, then driven low. In response, the READY output  
goes low while EEPROM memory is written.  
Programming commences. The unlock code at  
address 0x0020 is cleared, then device register and  
RAM contents are written to the serial EEPROM.  
During programming, the twos-complemented  
checksum is tallied for the entire address range being  
programmed (1K or 32K words), excluding addresses  
0x0002, 0x0006, 0x0008, 0x0014 and 0x0020. At  
EEPROM programming completion, the final  
checksum is stored in the pair of EEPROM locations  
corresponding to device RAM address 0x0020. The  
value written to EEPROM is actually the twos-  
complement of the memory checksum, (CHECKSUM  
+ 1). The value in EEPROM is used for error detection  
when performing auto-initialization. (The host can only  
access the stored value immediately after an auto-  
initialization sequence is performed. The twos-  
complement EEPROM checksum value will be copied  
into RAM address 0x0020.)  
1B. If using the existing EEPROM configuration as  
the baseline for a new EEPROM configuration:  
With the AUTOEN pin in logic 1 state and the TXINHA  
and TXINHB pins in logic zero state, apply MR master  
reset and wait for READY output assertion. Verify that  
the INTHW output does not pulse low (or go and  
remain low) at READY assertion. Confirm that the  
RTAPF, EECKF and RAMIF bits are all logic 0 in the  
Operational Status Register 0x0002. If the STEX bit in  
Configuration Register 1 was set by auto-initialization,  
reset it now. Modify register and RAM values to reflect  
the new changes. Go to Step 2.  
5. When the READY output goes high, EEPROM  
copy is complete. The STEX bit is reset in device  
Configuration Register 1.  
2. IMPORTANT: Any processing of valid bus  
commands between MR master reset and this point  
will cause auto-initialization checksum failure later,  
due to non-zero values written to read-only registers  
as a result of command processing. The device will not  
enter EEPROM copy mode at step 3 if valid command  
reception caused ACTIVE output assertion after MR  
reset occurred. If set, the STEX bit in Configuration  
Register 1 also locks-out EEPROM copy mode at  
programming step 3.  
The address range copied during EEPROM programming  
depends on the state of the EE1K input pin when rising  
edge occurs on the EECOPYinput:  
If EE1K is high when EECOPY is asserted, the lower  
1K x 16 address range from 0x0 to 0x03FF is copied  
from device registers and RAM to EEPROM. This  
includes all registers, all configuration tables in RAM  
and the primary Descriptor Table in RAM at address  
0x0200 to 0x03FF. The 1K x 16 write to EEPROM  
requires up to 65 ms.  
3. The host writes one of two 2-part “unlock codes” to  
RAM address 0x0020. The two unlock codes perform  
identical EEPROM programming with the exception of  
If EE1K is low when EECOPY is asserted, the entire  
32K x 16 address range from 0x0 to 0x7FFF is copied  
HOLT INTEGRATED CIRCUITS  
74  
HI-6120, HI-6121  
RESET AND INITIALIZATION, Cont.  
from device registers and RAM to EEPROM. This  
range covers all registers, all configuration tables in  
RAM, the primary Descriptor Table in RAM at address  
0x0200 to 0x03FF.As long as EE1K remains low when  
auto-initialization occurs, the 32K x 16 programming  
option can initialize secondary Descriptor Tables  
above address 0x0400, if used. The 32K x 16 write to  
EEPROM requires up to 1.9 seconds.  
The 32K x 16 programming option (EE1K equals zero) can  
also initialize fixed data for any subset of the 32 possible  
transmit subaddress buffers, using any of the defined data  
buffer schemes. To enable EEPROM copy for transmit  
subaddress data buffers, the buffer space must be pre-  
loaded with the desired data. Be sure to reserve space for  
Message Information and Time-Tag Word locations, as  
required for the transmit subaddress buffer method.  
HOST BUS INTERFACE (HI-6120 ONLY)  
In the HI-6120, internal RAM and registers occupy a 32K x  
16 address space. The lowest 32 addresses access  
registers and the remaining addresses access RAM  
locations.  
“little endian” is chosen; the low order byte (bits 7:0) is  
transacted before the high order byte (bits 15:8). When  
BENDI is high, “big endian” is chosen and the high order  
byte is transacted on the host bus before the low order  
byte. In 8-bit mode, all transacted data uses bus data bits  
7:0 and bus data bits 15:8 are not used. Further, bus  
address bit A0 (LB) always equals 0 during the first byte  
read/write access, and equals 1 during the second byte  
access  
The HI-6120 uses  
a parallel bus interface for  
communications with the host. Host interface to registers  
and RAM is enabled through the Chip Enable (CE) pin, and  
accessed via 16-bit data bus and several host-originated  
control signals described below. Timing is identical for  
register operations and RAM operations via the host bus  
interface, but read and write operations have different  
signal timing. The HI-6120 parallel host bus interface is  
capable of faster communication than the HI-6121 Serial  
Peripheral Interface.  
When the BWID pin is connected high or left unconnected,  
16-bit bus width is used. For 16-bit bus operation, the A0  
(LB) address pin is not used and the BENDI input pin is  
“don’t care.”  
AWAIToutput pin can be used to modify host timing for bus  
read cycles. For compatibility with different host  
processors, the WAIT output can be made active high or  
active low, set by the state of the WPOL input pin. The  
WAIT output may be ignored when the host processor’s  
read and write cycle times are consistent with worst case  
(slowest) read/write cycle timing for this device. The WAIT  
output is useful when the host processor runs at high clock  
rates and/or when processor options for read wait states  
do not provide adequate timing margin with worst case  
(slowest) read/write timing for this device. The WAIT is not  
used for write operations.  
Depending on the chosen microprocessor family, the  
processor’s hardware bus interface may be described as  
an “external bus interface,” “memory interface” or may  
have a different name. The user can also implement a  
software controlled “bit-banged” interface to the HI-6120,  
at the cost of substantially slower RAM and register  
read/write times.  
The bus interface is compatible with the two prevalent bus  
control signal methods: “Intel style” interface,  
characterized by separate strobes for read and write  
operations (OE and WE), and “Motorola style” interface,  
characterized by a single read/write strobe (STR) and a  
data direction signal (R/W). Bus control style is selected  
using the BTYPE configuration pin, which sets the function  
of two other input pins to serve as either OE and WE, or  
STR and R/W.  
WAIT is always asserted during the first read cycle. This  
may be the first byte read in 8-bit mode, or the first word  
read in 16-bit mode, possibly the first word read from a  
series of sequential addresses. After each word (or byte)  
is fetched by the device for a read operation, the next word  
(or byte) is pre-fetched from the next address to speed-up  
the read cycle time when immediate, sequential read to the  
next address occurs. For fastest read access under all  
conditions, the user can set host processor bus timing to  
match the faster rate for the second and subsequent read  
cycles, while using the WAIT output to pace access for the  
slower initial read cycle.  
The BWID configuration pin selects either 8- or 16-bit bus  
widths. When the BWID pin is connected to ground, 8-bit  
mode is selected; two bytes are sequentially transferred  
for each 16-bit word operation. In 8-bit mode only, the  
BENDI configuration pin selects bus “endianness.” This is  
the system attribute that indicates whether integers are  
represented with the most significant byte stored at the  
lowest address (big endian) or at the highest address (little  
endian). Internal device storage is “big endian”. For  
processor compatibility, the BENDI pin sets the order for  
byte accesses when the host bus is configured for 8-bit  
width, that is, when BWID equals 0. When BENDI is low,  
Timing diagrams for bus read and write operations are  
shown in the AC Electrical Characteristics section of the  
datasheet. Separate diagrams show “Intel style” and  
“Motorola style” control interfaces.  
HOLT INTEGRATED CIRCUITS  
75  
HI-6120, HI-6121  
HOST SERIAL PERIPHERAL INTERFACE (HI-6121 ONLY)  
In the HI-6121, internal RAM and registers occupy a 32K x  
16 address space. The lowest 32 addresses access  
registers and the remaining addresses access RAM  
locations. Timing is identical for register operations and  
RAM operations via the serial interface, and read and write  
operations have likewise identical timing.  
configuration setting in the HI-6121 to select SPI Mode 0 or  
Mode 3 because compatibility is automatic. Beyond this  
point, the HI-6121 data sheet only shows the SPI Mode 0  
SCK signal in timing diagrams.  
The SPI protocol transfers serial data as 8-bit bytes. Once  
CE chip enable is asserted, the next 8 rising edges on SCK  
latch input data into the master and slave devices, starting  
with each byte’s most-significant bit. The HI-6121 SPI can  
be clocked at 16 MHz.  
SERIALPERIPHERALINTERFACE (SPI) BASICS  
The HI-6121 uses an SPI synchronous serial interface for  
host access to registers and RAM. Host serial  
communication is enabled through the Chip Enable (CE)  
pin, and is accessed via a three-wire interface consisting of  
Serial Data Input (SI) from the host, Serial Data Output  
(SO) to the host and Serial Clock (SCK). All programming  
cycles are completely self-timed, and no erase cycle is  
required before write.  
Multiple bytes may be transferred when the host holds CE  
low after the first byte transferred, and continues to clock  
SCK in multiples of 8 clocks. A rising edge on CE chip  
enable terminates the serial transfer and reinitializes the  
HI-6121 SPI for the next transfer. If CE goes high before a  
full byte is clocked by SCK, the incomplete byte clocked  
into the device SI pin is discarded.  
The SPI (Serial Peripheral Interface) protocol specifies  
master and slave operation; the HI-6121 operates as an  
SPI slave.  
Two byte transfers are needed for SPI exchange of 16-bit  
register values or RAM data. “Big endian” byte order is  
used for SPI data transfers. The high order byte (bits 15:8)  
is transferred before the low order byte (bits 7:0).  
The SPI protocol defines two parameters, CPOL (clock  
polarity) and CPHA (clock phase). The possible CPOL-  
CPHA combinations define four possible "SPI Modes."  
Without describing details of the SPI modes, the HI-6121  
operates in the two modes where input data for each  
device (master and slave) is clocked on the rising edge of  
SCK, and output data for each device changes on the  
falling edge. These are known as SPI Mode 0 (CPHA = 0,  
CPOL= 0) and SPI Mode 3 (CPHA= 1, CPOL= 1). Be sure  
to set the host SPI logic for one of these modes.  
In the general case, both master and slave simultaneously  
send and receive serial data (full duplex) per Figure 21  
below. However the HI-6121 operates half duplex,  
maintaining high impedance on the SO output, except  
when actually transmitting serial data. When the HI-6121  
is sending data on SO during read operations, activity on  
its SI input is ignored. Figures 22 and 23 show actual  
behavior for the HI-6121 SO output.  
The difference between SPI Modes 0 and 3 is the idle state  
for the SCK signal, which is logic 0 for Mode 0 state and  
logic 1 for Mode 3 state (see figure 20). There is no  
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
SCK (SPI Mode 0)  
SCK (SPI Mode 3)  
SI  
MSB  
LSB  
LSB  
High Z  
High Z  
SO  
MSB  
CE  
FIGURE 21. Generalized Single-Byte Transfer Using SPI Protocol, SCK is Shown for SPI Modes 0 and 3  
HOLT INTEGRATED CIRCUITS  
76  
HI-6120, HI-6121  
HOST SERIAL PERIPHERAL INTERFACE, Cont. (HI-6121 ONLY)  
HI-6121 SPI COMMANDS  
register 15, consisting of command byte 0xBC followed by  
the desired 16-bit memory or register address. The pointer  
uses a 15-bit value to access any location in the 32K  
address range. The current address pointer value can be  
read using a fast-access read command byte 0x3C.  
For the HI-6121, each SPI read or write operation begins  
with an 8-bit command byte transferred from the host to the  
device after assertion of CE. Since HI-6121 command byte  
reception is half-duplex, the host discards the dummy byte  
it receives while serially transmitting the command byte.  
After a 2-byte read/write completion, the internal address  
pointer automatically increments to the following register  
address. The host may choose to extend the read or write  
operation to the next register address by continuing to hold  
CE low while clocking SCK 16 additional times. This auto-  
increment feature can be used to access one or more  
sequential register addresses above the command byte  
address. Auto-increment applies (ranging to the top of the  
address space) as long as SCK continues to be clocked  
under continuous CE assertion. Caution: When the  
primary address pointer is used for auto-incrementing  
multi-word read/write and reaches the top of the address  
range (0x7FFF) the next increment will roll over the pointer  
value to 0x0000. The host should avoid this situation.  
The HI-6121 SPI command set uses the most significant  
command bit to specify whether the command is Read or  
Write. The command byte MSB is zero for read  
commands, and one for write commands.  
FAST-ACCESS COMMANDS FOR REGISTERS 0-15  
The SPI command set includes directly-addressed read  
and write commands for registers 0 through 15. The 8-bit  
pattern for these commands has the general form  
W-0-R-R-R-R-0-0  
where RRRR is the 4-bit register address, and the most  
significant bit, W signifies Write when 1, or Read when 0.  
These fast-access commands appear at the top ofTable 2.  
————————————  
Figures 22 and 23 show read and write timing as it appears  
for fast-access register operations. The command byte is  
immediately followed by two data bytes comprising the 16-  
bit data word read or written. For a register read or write,  
CE is negated after the 2-byte data word is transferred.  
Three single-byte SPI commands modify the current  
address pointer value in register 15:  
Command  
0xD0  
0xD8  
Address Pointer Operation  
add 1 to the current pointer value  
add 2 to the current pointer value  
add 4 to the current pointer value  
RAMAND REGISTER INDIRECTADDRESSING  
Refer to the HI-6121 SPI command set shown in Table 2.  
SPI commands other than fast-access use an address  
pointer to indicate the address for read or write  
transactions. This “primary address pointer” resides at  
register address 15, and must be initialized before any  
non-fast-access read or write operation.  
0xE0  
The “Add 4” command may be useful when sequentially  
accessing the same word (for example, the Control Word)  
in a series of 4-word Descriptor Table entries. The “Add 2”  
command might be useful for reading the Interrupt Log  
Buffer, comprised of 2-word log entries. In both cases, the  
Add command would be probably followed by Read  
command 0x40 to read the location addressed by the  
To set the address pointer, use a fast-access write to  
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
SCK  
SPI Mode 0  
MSB  
LSB  
SI  
Command Byte  
MSB  
LSB MSB  
LSB  
High Z  
High Z  
SO  
Data Byte 0  
Data Byte 1  
CE  
Host may continue to assert CE  
here to read sequential word(s).  
Each word needs 16 SCK clocks.  
FIGURE 22. Single-Word (2-Byte) Read From RAM or a Register  
HOLT INTEGRATED CIRCUITS  
77  
HI-6120, HI-6121  
HOST SERIAL PERIPHERAL INTERFACE, Cont. (HI-6121 ONLY)  
current pointer value. Similarly, Write command 0xC0  
writes the location addressed by the current pointer value.  
Two command bytes cannot be “chained”; CE must be  
negated after the Add command, then reasserted for the  
following Read or Write command.  
These two commands can be used to read or write a single  
location, or may be used to start a multi-word read or write  
that uses the pointer’s auto-increment feature.  
The primary address pointer is not affected by fast-access  
read/writes to registers 0-14 because fast-access SPI  
commands use a separate, internal pointer not directly  
accessible to the host.  
SPECIALPURPOSE COMMANDS  
Several other HI-6121 SPI commands load or otherwise  
modify the primary address pointer before initiating a read  
or write process. These commands were tailored to the  
specific needs of HI-6121 RemoteTerminal host software.  
————————————  
————————————  
Just two single-byte SPI commands use the current  
address pointer value in register 15 without first loading or  
otherwise modifying it:  
Using a single-byte SPI command, the address pointer can  
be directly loaded with the memory address for the  
descriptor table Control Word corresponding to the last  
completed MIL-STD-1553 command. The Control Word is  
then read.  
Command Read Operation  
0x40  
read location addressed by pointer value  
Command Write Operation  
0xC0  
Command Read Operation  
write location addressed by pointer value  
0x50  
Copy Current Control WordAddress register  
13 to address pointer register 15. Read the  
location addressed by the new pointer value.  
Either of these commands can be used to read or write a  
single location, or may be used when starting a multi-word  
read or write by using the pointer’s auto-increment feature.  
————————————  
This command can be used to read just the current Control  
Word, or may be used to start a multi-word read because  
memory pointer auto-increment occurs after the Control  
Word is read.  
Two single-byte SPI commands increment the current  
address pointer value in register 15, then perform a read or  
write:  
————————————  
Six single-byte SPI commands add an offset to the current  
address pointer value, then read the addressed memory  
location; the read value is then written to the address  
pointer register 15. The new pointer value is used to start a  
read or write operation:  
Command Read Operation  
0x48  
add 1 to pointer then read addressed location  
Command Write Operation  
0xC8 add 1 to pointer then write addressed location  
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
SCK  
SPI Mode 0  
MSB  
LSB MSB  
LSB MSB  
LSB  
SI  
Command Byte  
Data Byte 0  
Data Byte 1  
High Z  
SO  
CE  
Host may continue to assert CE  
here to write sequential word(s).  
Each word needs 16 SCK clocks.  
FIGURE 23. Single-Word (2-Byte) Write To RAM or a Register  
HOLT INTEGRATED CIRCUITS  
78  
HI-6120, HI-6121  
HOST SERIAL PERIPHERAL INTERFACE, Cont. (HI-6121 ONLY)  
Command Read Operation  
Command Read Operation  
0x60  
0x68  
0x70  
0x78  
Read the location addressed by the memory  
address pointer. Write the value just read into  
the memory address pointer. Then read.  
read addressed location then add 4 to pointer  
Primary use occurs when the address pointer initially  
points to the first Descriptor Table Control Word in a series  
of Control Words to be polled (every fourth word).  
Add 1 to the memory address pointer. Read  
value at newly addressed location and write it  
into the memory address pointer. Then read.  
After 8 SCK clocks for the SPI command, each instance of  
this command reads a single location using 16 SCK clocks.  
If CS remains low after 24 clocks and SCK continues, a  
multi-word read begins, using the address pointer’s auto-  
increment feature. The second word read is at (Control  
Word address + 4), the next Control Word in the table.  
————————————  
Add 2 to the memory address pointer. Read  
value at newly addressed location and write it  
into the memory address pointer. Then read.  
Command Write Operation  
Another single-byte SPI command is useful when  
servicing interrupts. When enabled interrupts occur, two  
words are written to the circular 32-word Interrupt Log  
Buffer, and the Interrupt Log Address register 9 is updated  
to show the storage address where interrupt information  
words will be stored for the next occurring interrupt.  
Buffer starting address is 0x0040 and ending address is  
0x005F. Because two words are written to the buffer for  
each interrupt, the Interrupt Log Address register always  
contains an even value in the range of 0x0040 to 0x005E.  
0xE8  
0xF0  
0xF8  
Read the location addressed by the memory  
address pointer. Write the value just read into  
the memory address pointer. Then write.  
Add 1 to the memory address pointer. Read  
value at newly addressed location and write it  
into the memory address pointer. Then write.  
Add 2 to the memory address pointer. Read  
value at newly addressed location and write it  
into the memory address pointer. Then write.  
When servicing an interrupt that just occurred, the host  
wants timely information on that interrupt. An SPI  
command is provided to simplify interrupt handling:  
Primary use occurs when a Descriptor Table Control Word  
was just read. For example, the last op code performed  
was 0x50, reading the Control Word for the last command.  
After reading the Control Word, the memory pointer has  
automatically incremented. The host can examine flag bits  
contained in the just-read Control Word to determine the  
applicable data buffer (e.g., Data BufferA, Data Buffer B or  
the Broadcast Data Buffer) then directly service that buffer  
using these op codes; the three data buffer pointers occur  
in the three words following the initially read Control Word.  
Command Read Operation  
0x58  
write memory address pointer 0x000F with  
current value in Interrupt LogAddress register  
minus 1. If the Log Address register contains  
0x0040 then 0x005F is written to memory  
pointer register. Then read the addressed  
RAM location, containing the last-written  
Interrupt Address Word. Then decrement the  
memory address pointer, addressing the  
corresponding Interrupt Information Word.  
These six commands can be used to read or write a single  
location, or may be used to start a multi-word read or write  
that uses the pointer’s auto-increment feature.  
————————————  
This command can be used to read a single location, or  
may be used to start a multi-word read in which the  
memory address pointer automatically decrements after  
each word read. This is the only SPI op code that  
decrements the memory pointer for multi-word operations.  
Repeated memory pointer decrements will wrap around  
the 0x0040 to 0x005F log buffer boundary.  
When some or all subaddress or mode commands are not  
programmed to trigger host interrupts, a different single-  
byte SPI command may be useful if polling the Descriptor  
Table for message activity. In this situation, the host may  
poll a series of Descriptor Table Control Words looking for  
instances where the DBAC activity bit is set. The DBAC  
(Descriptor BlockAccessed) flag is set in the Control Word  
each time the corresponding command is completed. The  
process of reading the Control Word automatically resets  
the register’s DBAC bit so the host can detect activity the  
next time the DBAC flag is set by the device.  
————————————  
Since Descriptor Table Control Words are spaced four  
words apart, this command is useful when polling a series  
of descriptor table Control Words:  
HOLT INTEGRATED CIRCUITS  
79  
HI-6120, HI-6121  
HOST SERIAL PERIPHERAL INTERFACE (SPI), Cont.  
FAST-ACCESS SPI COMMANDS FOR REGISTERS 0-15  
Command Bits 5:2 Convey the 4-Bit Register Address  
COMMAND BITS  
7 6 5 4 3 2 1 0  
HEX  
BYTE  
FAST-ACCESS  
READ  
COMMAND BITS  
7 6 5 4 3 2 1 0  
HEX  
BYTE  
FAST-ACCESS  
WRITE  
0 0 0 0 0 0 0 0  
0 0 0 0 0 1 0 0  
0 0 0 0 1 0 0 0  
0 0 0 0 1 1 0 0  
0 0 0 1 0 0 0 0  
0 0 0 1 0 1 0 0  
0 0 0 1 1 0 0 0  
0 0 0 1 1 1 0 0  
0 0 1 0 0 0 0 0  
0 0 1 0 0 1 0 0  
0 0 1 0 1 0 0 0  
0 0 1 0 1 1 0 0  
0 0 1 1 0 0 0 0  
0 0 1 1 0 1 0 0  
0 0 1 1 1 0 0 0  
0 0 1 1 1 1 0 0  
0x00  
0x04  
0x08  
0x0C  
0x10  
0x14  
0x18  
0x1C  
0x20  
0x24  
0x28  
0x2C  
0x30  
0x34  
0x38  
0x3C  
Read register 0  
Read register 1  
Read register 2  
Read register 3  
Read register 4  
Read register 5  
Read register 6  
Read register 7  
Read register 8  
Read register 9  
Read register 10  
Read register 11  
Read register 12  
Read register 13  
Read register 14  
Read register 15  
1 0 0 0 0 0 0 0  
1 0 0 0 0 1 0 0  
1 0 0 0 1 0 0 0  
1 0 0 0 1 1 0 0  
1 0 0 1 0 0 0 0  
1 0 0 1 0 1 0 0  
1 0 0 1 1 0 0 0  
1 0 0 1 1 1 0 0  
1 0 1 0 0 0 0 0  
1 0 1 0 0 1 0 0  
1 0 1 0 1 0 0 0  
1 0 1 0 1 1 0 0  
1 0 1 1 0 0 0 0  
1 0 1 1 0 1 0 0  
1 0 1 1 1 0 0 0  
1 0 1 1 1 1 0 0  
0x80  
0x84  
0x88  
0x8C  
0x90  
0x94  
0x98  
0x9C  
0xA0  
0xA4  
0xA8  
0xAC  
0xB0  
0xB4  
0xB8  
0xBC  
Write register 0  
Write register 1  
Write register 2  
Write register 3  
Write register 4  
Write register 5  
Write register 6  
Write register 7  
Write register 8  
Write register 9  
Write register 10  
Write register 11  
Write register 12  
Write register 13  
Write register 14  
Write register 15  
SPI COMMANDS USING ADDRESS POINTER REGISTER  
HEX  
BYTE  
READ or  
WRITE  
READ  
Address Pointer Operations (no data is written or read, no pointer auto-increment)  
Add 1 to the current address pointer value in register 15  
Add 2 to the current address pointer value in register 15  
0xD0  
0xD8  
0xE0  
Add 4 to the current address pointer value in register 15  
Read / Write RAM or Register Location Using Current Address Pointer Value  
Read location addressed by current address pointer value in register 15  
Write location addressed by current address pointer value in register 15  
0x40  
0xC0  
R
W
Increment Address Pointer Then Read / Write Addressed RAM or Register Location  
Read addressed location after incrementing pointer in register 15  
Write addressed location after incrementing pointer in register 15  
0x48  
0xC8  
R
W
Special Purpose Commands  
Copy register 13 (current Control Word address) to address pointer in register 15, then  
read the location addressed by the new pointer value (read the current Control Word)  
0x50  
R
0x68  
0x70  
0x78  
R
R
R
Add 0 to the current address pointer value in register 15. Then . . .  
Add 1 to the current address pointer value in register 15. Then . . .  
Add 2 to the current address pointer value in register 15. Then copy value from newly  
addressed location to address pointer in register 15 then read newly addressed location.  
0xE8  
0xF0  
0xF8  
W
W
W
Add 0 to the current address pointer value in register 15. Then . . .  
Add 1 to the current address pointer value in register 15. Then . . .  
Add 2 to the current address pointer value in register 15. Then copy value from newly  
addressed location to address pointer in register 15 then write newly addressed location.  
0x60  
0x58  
R
R
Read then add 4 to the current address pointer value in register 15.  
Write storage address of last-written Interrupt Address Word to the address pointer  
in register 15, then read the Interrupt Address Word from the Interrupt Log buffer.  
Decrement memory address pointer after read operation.  
TABLE 2. SUMMARY OF HI-6121 SERIAL PERIPHERAL INTERFACE (SPI) COMMANDS  
HOLT INTEGRATED CIRCUITS  
80  
HI-6120, HI-6121  
Table 3. RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Invalid Command  
Word (Manchester,  
parity or bit count error)  
No terminal response,  
the message is ignored.  
No Status Word change.  
No change  
No Message Info  
Word is written  
None  
Any valid command  
to RT31 (broadcast).  
when the BCSTINV  
bit in Configuration  
Register 1 equals 1.  
No terminal response,  
the message is ignored.  
No Status Word change.  
(Broadcast commands  
are rendered invalid.)  
No change  
No Message Info  
Word is written  
None  
RT Address Parity Error  
based on RTA and RTAP  
bits in the Operational  
Status Register  
For commands to the RT’s  
own address or to broadcast  
address RT31: No terminal  
response, message is ignored.  
No Status Word change.  
No change  
No Message Info  
Word is written  
RTAPF  
(not  
optional)  
Any valid non-mode  
(subaddress 1-30)  
transmit command  
to RT31 (undefined  
broadcast transmit).  
No terminal response,  
Set Message Error (ME)  
and BCR status bits.  
DBAC bit set.  
DPB bit toggles.  
BCAST bit set.  
MERR bit set.  
BUSID bit updated.  
IWA  
IBR  
(IXEQZ)  
Any valid non-mode  
(subaddress 1-30)  
transmit command  
except for RT31. The  
corresponding bit  
in the Illegalization  
Table equals 0. *  
Normal Status Word response  
(Clear Status). Data words for  
transmit are read from the  
RAM data buffer assigned  
by the Descriptor Table entry  
for the transmit subaddress.  
DBAC bit set.  
DPB bit toggles.  
BCAST bit reset.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit updated.  
(Other error bits reset).  
IWA  
IBR  
(IXEQZ)  
Any valid non-mode  
(subaddress 1-30)  
transmit command  
except for RT31. The  
corresponding bit  
in the Illegalization  
Table equals 1. **  
Assert Message Error (ME)  
status, then transmit  
ME Status Word  
DBAC bit set.  
DPB bit toggles.  
BCAST bit reset.  
ILCMD bit set.  
BUSID bit updated.  
MERR bit set.  
RTRT bit updated.  
(Other error bits reset).  
ILCMD  
IWA  
without following data words.  
Any valid non-mode  
(subaddress 1-30)  
receive command.  
The corresponding bit  
in the Illegalization  
Table equals 0. *  
Normal Status Word response  
(Clear Status). After message  
completion, the data words  
received are stored in the data  
buffer RAM location assigned  
by the Descriptor Table entry  
for the receive subaddress.  
DBAC bit set.  
DPB bit toggles.  
BCAST bit reset.  
Normal update:  
IWA  
IBR  
(IXEQZ)  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit updated.  
(Other error bits reset).  
Any valid non-mode  
(subaddress 1-30)  
receive command.  
The corresponding bit  
in the Illegalization  
Table equals 1. **  
Assert Message Error (ME)  
status and set BCR if broadcast.  
Any received data words are  
ignored and are not saved.  
When data reception stops,  
transmit Status Word.  
DBAC bit set.  
DPB bit toggles.  
BCAST bit updated.  
ILCMD bit set.  
BUSID bit updated.  
MERR bit set.  
RTRT bit updated.  
(Other error bits reset)  
ILCMD  
IWA  
IBR  
(IXEQZ)  
* Terminal is using “illegal command detection” and command is legal  
OR terminal is not using “illegal command detection” and command may be legal or illegal (in form response).  
**Terminal is using “illegal command detection” and command is illegal  
HOLT INTEGRATED CIRCUITS  
81  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Valid receive  
No terminal response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
command followed  
by invalid data word  
(Manchester, parity  
or bit count error).  
Set Message Error (ME) status.  
If broadcast (RT31), also set  
the BCR status bit.  
BUSID bit updated.  
IWDERR bit set.  
ILCMD bit reset.  
RTRT bit updated.  
(Other error bits reset).  
Valid receive command  
followed by one or more  
good data words, then  
a data word having  
Command Sync  
No terminal response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
Set Message Error (ME) status.  
If broadcast (RT31), also set  
the BCR status bit,  
BUSID bit updated.  
SYNERR bit set.  
ILCMD bit reset.  
(Other error bits reset).  
Any valid command  
followed by wrong  
number of data  
words (too few or  
too many words)  
No terminal response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
Set Message Error (ME) status.  
If broadcast (RT31), also set  
the BCR status bit,  
BUSID bit updated.  
Set WCTERR (too few)  
or GAPERR (too many).  
ILCMD bit reset.  
RTRT bit updated.  
(Other error bits reset).  
RT-RT where CW1  
is a valid non-mode  
receive command.  
CW2 is a non-mode  
transmit command  
valid for different RT.  
(Normal RT-RT  
Normal Status Word response  
(Clear Status). If RT-RT Command  
Word 1 is broadcast (RT31)  
set the BCR status bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
RTRT bit set.  
RTCWERR bit reset.  
ILCMD bit reset.  
(All error bits reset).  
IWA  
IBR  
(IXEQZ)  
receive message)  
RT-RT where CW1  
is a valid non-mode  
receive command.  
Transmit command  
CW2 has an error:  
T/R bit = 0, or CW2  
subaddress equals  
0 or 31 (mode code),  
or CW2 has same RT  
address as CW1.  
No terminal response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
BUSID bit updated.  
RTRT bit set.  
RTRTCWERR bit set.  
ILCMD bit reset.  
(Other error bits reset).  
MERR  
IWA  
IBR  
Set Message Error (ME) status.  
If RT-RT Command Word 1 is  
broadcast (RT31) also set  
the BCR status bit,  
RT-RT where CW1  
is a valid non-mode  
receive command.  
CW2 is valid for different  
RT but transmitting RT  
does not respond in time.  
No terminal response.  
DBAC bit set.  
BCAST bit updated  
DPB bit toggles.  
MERR bit set.  
BUSID bit updated.  
RTRT bit set.  
TMOERR bit set.  
ILCMD bit reset.  
(Other error bits reset).  
MERR  
IWA  
IBR  
Set Message Error (ME) status.  
If RT-RT Command Word 1 is  
broadcast (RT31), also set  
the BCR status bit.  
RT-RT receive command  
(CW1 is valid). The  
No terminal response.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
MERR bit set.  
BUISID bit reset.  
RTRT bit set.  
IWDERR bit set,  
or WCTERR bit set  
for Tx RT Busy case.  
ILCMD bit reset.  
(Other error bits reset).  
MERR  
IWA  
IBR  
Set Message Error (ME) status.  
If RT-RT Command Word 1 is  
broadcast (RT31) also set  
the BCR status bit.  
transmitting RT response  
has one of these errors:  
invalid word (Manchester,  
(sync, bit count, parity or  
word count error). Also  
includes transmitting RT  
response with Message  
Error or Busy status  
followed by no data words.  
HOLT INTEGRATED CIRCUITS  
82  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
RT-RT command  
where CW2 is a  
valid non-mode  
(subaddress 1-30)  
transmit command.  
CW1 is a non-mode  
receive command  
for RT31. (Normal  
broadcast RT-RT  
transmit)  
Normal Status Word  
response. Clear status  
is transmitted with the  
commanded number of  
data words. Data words for  
transmit are read from the  
RAM data buffer assigned  
in the Descriptor Table entry  
for the transmit subaddress.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit set.  
IWA  
(IXEQZ)  
(All error bits reset).  
Valid mode code  
command to RT31  
(broadcast). The  
BCSTINV bit in  
Configuration  
Register 1 equals 1.  
No terminal response,  
the message is ignored.  
No Status Word change.  
No change  
No change  
No Message Info  
Word is written  
None  
None  
Valid undefined  
mode code  
command. The  
UMCINV bit in  
Configuration  
No terminal response,  
No Message Info  
Word is written  
the message is ignored.  
No Status Word change.  
——— NOTE ———  
This only applies for the  
undefined mode codes:  
MC0 to MC15 with T/R = 0  
MC16,18 & 19 with T/R = 0  
MC17,20 & 21 with T/R = 1  
Register 1 equals 1.  
Valid defined mode  
code command  
(including reserved  
mode code) not  
“illegalized” by  
If MC2 (transmit status)  
or MC18 (transmit last  
command) status word  
from last command is  
transmitted. If MC18,  
data word transmitted  
is read from an internal  
register.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
(IXEQZ)  
Illegalization Table  
(table bit equals 0 *)  
——— OR ———  
If not MC2 or MC18,  
normal Status Word  
response. If broadcast,  
assert Status Word  
BCR bit.  
For mode codes 16-31  
with T/R bit = 1 which  
transmit a data word,  
the word for transmit  
is read from the Mode  
Command Data Table.  
——— AND ———  
For all mode commands  
with mode data word  
(mode codes 16-31),  
the transmitted or  
received data word is  
written to command’s  
Descriptor Word 4.  
* Terminal is using “illegal command detection” and command is legal  
OR terminal is not using “illegal command detection” and command may be legal or illegal (in form response).  
HOLT INTEGRATED CIRCUITS  
83  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Valid defined mode  
code command that  
is “illegalized” by the  
IllegalizationTable  
Set Message Error (ME) status.  
If not broadcast (RT31), transmit.  
Status Word without a following  
mode data word. If broadcast  
(RT31), also assert the BCR  
status bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
ILCMD  
IWA  
IBR  
BUSID bit updated.  
MERR bit reset.  
RTRT bit reset.  
(table bit equals 1 **)  
(Other error bits reset.)  
——— AND ———  
For mode commands with  
a mode data word  
(mode codes 16-31),  
no updates are made to  
the Mode Command Data  
Table or to the command’s  
Word 4 in Descriptor Table.  
Valid undefined mode  
code command.  
The UMCINV bit  
in Configuration  
Register 1 equals 0.  
If bit in Illegalization Table that  
corresponds to the undefined  
mode code command equals 1 **  
Set Message Error (ME) status,  
If not broadcast (RT31), transmit  
Status Word without a  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
ILCMD  
IWA  
IBR  
BUSID bit updated.  
MERR bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
following mode data word.  
If broadcast (RT31), also  
assert the BCR status bit.  
——— OR ———  
If bit in Illegalization Table that  
corresponds to the undefined  
mode code command equals 0 *  
Normal Status Word (Clear  
Status) response. If command  
was broadcast (RT31),  
assert the BCR status bit.  
——— AND ———  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
(IXEQZ)  
.
For mode codes 16-31  
with T/R bit = 1 which  
transmit a data word,  
the word for transmit  
is read from the Mode  
Command Data Table.  
——— AND ———  
For all mode commands  
with mode data word  
(mode codes 16-31),  
the transmitted or  
received data word is  
written to command’s  
Descriptor Word 4.  
* Terminal is using “illegal command detection” and command is legal  
OR terminal is not using “illegal command detection” and command may be legal or illegal (in form response).  
**Terminal is using “illegal command detection” and command is illegal.  
HOLT INTEGRATED CIRCUITS  
84  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Valid receive  
No terminal response.  
Set Status Word ME bit,  
If broadcast, also set  
Status Word BCR bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
command followed  
by invalid data word  
(Manchester, parity  
or bit count error).  
BUSID bit updated.  
IWDERR bit set.  
ILCMD bit reset.  
RTRT bit updated.  
(Other error bits reset.)  
Superseded Message:  
Terminal receives an  
incomplete message  
interrupted by a gap  
of at least 3.5 us,  
followed by a new  
valid command on  
the same bus or  
Terminal aborts processing  
for first message and  
responds in full to the  
second (superseding)  
message. The Status  
Word BCR bit reflects  
broadcast status for:  
the second command,  
unless second command  
is MC2 (transmit status)  
or MC18 (transmit last  
command).  
No change  
to superseded  
command’s  
Control Word.  
——————  
For superseding  
command’s  
Control Word:  
DBAC bit set.  
BCAST bit updated  
DPB bit toggles.  
No Msg Info  
None for  
superseded  
command  
Word written for  
the superseded  
command.  
——————  
————  
IWA  
IBR  
For superseding  
command’s  
data buffer, a  
normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit updated.  
(All error bits reset.)  
(IXEQZ)  
on the other bus  
——— OR ———  
Terminal is transacting  
a transmit message on  
one bus and receives  
the start of a valid  
command on the other  
bus.  
Terminal is Busy for a  
valid receive command  
either globally (BUSY  
bit set in Status Word  
Bits register) or in  
response to a particular  
valid receive command  
(MKBUSY bit set in the  
command’s Descriptor  
Table control word.)  
Busy bit is set in the 1553  
Status Bits register. Status  
Word is transmitted,  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
WASBSY bit set.  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit updated.  
(All error bits reset.)  
IWA  
IBR  
unless broadcast. If  
broadcast, the BCR bit  
in Status Word is also  
set. After message  
completion, data words  
received are stored in  
the data buffer assigned  
by the receive subaddress  
Descriptor Table entry.  
Terminal is Busy for a  
valid transmit command  
either globally (BUSY  
bit set in Status Word  
Bits register) or in  
response to a particular  
valid receive command  
(MKBUSY bit set in the  
command’s Descriptor  
Table control word.)  
Busy bit is set in the 1553  
Status Bits register. If not  
broadcast, Status Word is  
transmitted without data.  
If broadcast, the BCR bit  
in Status Word is also  
set.  
DBAC bit set.  
WASBSY bit set.  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit updated.  
(All error bits reset.)  
IWA  
IBR  
BCAST bit updated,  
(mode commands  
with T/R = 1)  
DPB bit toggles  
FOLLOWING PAGES LIST THE DETAILED RESPONSES FOR MODE CODE COMMANDS  
PER MIL-STD-1553B  
HOLT INTEGRATED CIRCUITS  
85  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 00000  
and T/R bit equals 1  
HI-6110 is not equipped to accept  
bus control duties. The host must  
initialize device to respond using  
either of the two following methods:  
DYNAMIC BUS  
CONTROL (MC0)  
The mode code’s bit  
in Illegalization Table  
equals 0 *  
RT is not using “illegal  
command detection.”  
Respond “in form”: Reset  
Message Error (ME) status  
and transmit Status Word.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
——— OR ———  
——— OR ———  
The mode code’s bit  
in Illegalization Table  
equals 1 **  
RT is using “illegal  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
ILCMD bit set.  
ILCMD  
IWA  
command detection”and  
mode code is illegalized.  
Set Message Error (ME)  
status and transmit Status.  
BUSID bit updated.  
MERR bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
MC0 EXCEPTIONS:  
Broadcast address RT31  
(broadcast not allowed)  
No Status Word transmit.  
Set the Message Error  
(ME) and BCR status bits.  
DBAC bit set.  
BCAST bit set.  
DPB toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
Mode code command  
word is followed by a  
contiguous data word  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
MERR bit set.  
WCTERR bit set.  
BUSID bit updated.  
ILCMD, RTRT bits reset.  
(Other error bits reset.)  
MERR  
IWA  
Invalid command word.  
——— OR ———  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(MC0 is not ndefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 0.  
Illegalization Table  
bit equals 0 *  
Respond “In form”:  
Reset Message Error  
(ME) status and  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
transmit Status Word.  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 0.  
Illegalization Table  
bit equals 1 **  
Set Message Error  
(ME) status and.  
transmit Status Word.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
86  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 00001  
and T/R bit equals 1  
Default response: Reset  
Message Error (ME) status  
then transmit Status Word.  
If broadcast, set the Status  
Word BCR bit and suppress  
Status Word transmit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal update:  
IWA  
IBR  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
SYNCHRONIZE  
WITHOUT  
DATA  
Reset the Time Tag counter  
to 0x0000.  
(All error bits reset.)  
(MC1)  
MC1 EXCEPTIONS:  
Invalid command word.  
——— OR ———  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
The Time Tag counter is  
not reset.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal update:  
IWA  
IBR  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
The Time Tag counter is  
not reset.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word is followed by a  
contiguous data word  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
WCTERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
87  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 00010  
and T/R bit equals 1  
No Status Word updates,  
Transmit Status from last  
valid command (assuming  
last command was not a  
“Transmit Status” or a  
“Transmit last Command”  
mode command.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
TRANSMIT  
STATUS  
(MC2)  
MC2 EXCEPTIONS:  
Broadcast address RT31  
(broadcast not allowed)  
No Status Word transmit.  
Set the Message Error  
(ME) and BCR status bits.  
DBAC bit set.  
BCAST bit set.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
Invalid command word.  
——— OR ———  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
Time Tag counter is not reset.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0  
The Illegalization Table.  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word is followed by a  
contiguous data word  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
WCTERR bit set.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
88  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 00011  
and T/R bit equals 1  
Default response: Reset  
Message Error (ME) status  
then transmit Status Word.  
If broadcast, set the  
Status Word BCR bit and  
suppress status transmit.  
Host should initiate self-  
test then update Built-In  
Test word at shared RAM  
address 0x0093. Resume  
terminal execution.  
DBAC bit reset.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
INITIATE  
SELF TEST  
(MC3)  
MC3 EXCEPTIONS:  
Invalid command word.  
——— OR ———  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
IWA  
IBR  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word is followed by a  
contiguous data word  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
WCTERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
89  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 00100  
and T/R bit equals 1  
Default response: Reset  
DBAC bit reset.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
Message Error (ME) status  
then transmit Status Word. If  
broadcast, set Status Word  
BCR bit and suppress status.  
transmit. After Status trans-  
mission, inhibit the inactive bus:  
TRANSMITTER  
SHUTDOWN  
(MC4)  
The device automatically shuts down either transmit and receive or transmit only for  
the inactive bus, depending on the state of the SDSEL bit in Configuration Register 2.  
(See description of SDSEL and MCOPT4 bits in Configuration Register 2 for further information.  
When a bus transmitter (or transmitter and receiver) is shut down by mode command, bus status  
is reflected by assertion of a TXASD or TXBSD bit in the Built-In Test Register at register address  
0x0014. If SDSEL equals logic 0, an RXASD or RXBSD bit will also be asserted. See Built-In Test  
Register description for further information.  
Once shutdown, the inactive bus transmitter (or transmitter and receiver) can only be  
reactivated by an “Override Transmitter Shutdown” MC5 or MC21 or “Reset Remote Terminal” MC8  
mode code command, or by software reset (by setting the SRST bit in Configuration Register 1)  
or by hardware reset initiated by asserting the MR master reset input pin.  
MC4 EXCEPTIONS:  
Invalid command word.  
——— OR ———  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word is followed by a  
contiguous data word  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
WCTERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
90  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 00101  
and T/R bit equals 1  
Default response: Reset  
Message Error (ME) status  
then transmit Status Word.  
If broadcast, set the  
Status Word BCR bit and  
suppress status transmit.  
This command is only used  
with dual redundant buses.  
After Status transmission,  
reactivate inactive bus:  
DBAC bit reset.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
OVERRIDE  
TRANSMITTER  
SHUTDOWN  
(MC5)  
The device automatically re-enables transmit and receive for the inactive bus, regardless of  
the state of the SDSEL bit in Configuration Register 2. The device affirms reenabled bus status  
by resetting all four TXASD, TXBSD, RXASD and/or RXBSD bits in the Built-In Test Register  
at register address 0x0014.  
Note: If the TXINHA or TXINHB input pins are asserted, the device cannot override the  
resulting hardware transmit inhibit for the affected bus. In this case, the corresponding TXASD  
and/or TXBSD bits remain high. See Built-In Test Register description for further information.  
MC5 EXCEPTIONS:  
Invalid command word.  
——— OR ———  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word is followed by a  
contiguous data word  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
WCTERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
91  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 00110  
and T/R bit equals 1  
Default response: Reset  
Message Error (ME) status  
then transmit Status Word.  
If broadcast, set the  
Status Word BCR bit and  
suppress status transmit.  
DBAC bit reset.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
INHIBIT  
TERMINAL  
FLAG BIT  
(MC6)  
The device automatically sets the TF Inhibit bit in the BIT Word register at  
address 0x0013. While the TF inhibit bit is set, the device disregards  
assertion of the Terminal Flag (TF) bit in the 1553 Status Bits register (0x0006)  
and only transmits status with the Terminal Flag status bit reset.  
Once the Terminal Flag has been inhibited, it can be reactivated by an “Override  
Inhibit Terminal Flag” MC7 or “Reset Remote Terminal” MC8 mode command,  
by software reset (asserting the SRST bit in Configuration Register 1) or by  
asserting the MR master reset input pin.  
MC6 EXCEPTIONS:  
Invalid command word.  
——— OR ———  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
MERR bit reset.  
RTRT bit reset.  
ILCMD  
IWA  
IBR  
(Other error bits reset.)  
Mode code command  
word is followed by a  
contiguous data word  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
WCTERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
92  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 00111  
and T/R bit equals 1  
Default response: Reset  
Message Error (ME) status  
then transmit Status Word.  
If broadcast, set the  
Status Word BCR bit and  
suppress status transmit.  
DBAC bit reset.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
OVERRIDE  
INHIBIT  
TERMINAL  
FLAG BIT  
(MC7)  
The device automatically resets the TF Inhibit bit in the BIT Word register at  
address 0x0013. While the TF inhibit bit is reset, the device transmits status  
with the Terminal Flag status bit set if the Terminal Flag (TF) bit is asserted in the  
1553 Status Bits register (0x0006).  
MC7 EXCEPTIONS:  
Invalid command word.  
——— OR ———  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word is followed by a  
contiguous data word  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
WCTERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
93  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 01000  
and T/R bit equals 1  
Default response: Reset  
Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
DBAC bit reset.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
RESET  
REMOTE  
TERMINAL  
(MC8)  
After Status transmission, the device automatically resets the status Message Error (ME)  
Busy and Broadcast Command received (BCR) bits in its internal status register. The BIT Word  
at shared RAM address is reset to 0x0000. If either transmitter was shutdown, the shutdown  
condition is overridden. If the Terminal Flag (TF) status bit was inhibited, the inhibit is reset.  
This command does not reset any of the host-programmed registers that configure the  
terminal for operation. To complete the terminal reset process, the host must assert either  
MR hardware master reset (with or without auto-initialization) or assert the SRST bit  
in Configuration Register 1 to execute software reset. See following section entitled  
Reset and Initialization for additional details. Because MC8 requires host interaction,  
most applications will probably utilize the IWA interrupt to alert the host when received.  
MC8 EXCEPTIONS:  
Invalid command word.  
——— OR ———  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word is followed by a  
contiguous data word  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
GAPERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
BCAST bit reset.  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
94  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode codes  
01001 through 01111  
and T/R bit equals 1  
The reserved mode code  
commands do not have  
defined terminal actions.  
RESERVED  
MODE CODES  
MC9 - MC15  
Host must initialize device  
to respond using either of  
the two following methods:  
The mode code’s bit  
in Illegalization Table  
equals 0 *  
RT is not using “illegal  
command detection.”  
Respond “in form”: Reset  
Message Error (ME) status  
and transmit Status Word.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit reset.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
IWA  
(All error bits reset.)  
The mode code’s bit  
in Illegalization Table  
equals 1 **  
RT is using “illegal  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
command detection”and  
mode code is illegalized.  
Set Message Error (ME)  
status and transmit Status  
Word.  
MC9-MC15 EXCEPTIONS:  
Invalid command word.  
——— OR ———  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word is followed by a  
contiguous data word  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
WCTERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
95  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 10000  
and T/R bit equals 1  
Default CS response:  
DBAC bit reset.  
BCAST bit reset.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
Reset Message Error (ME)  
and BCR status bits. then  
transmit Status Word  
followed by the data word  
stored in the assigned index or  
ping-pong data buffer (or in  
Descriptor Word 4 for SMCP  
Simplified Mode Command  
Processing).  
TRANSMIT  
VECTOR WORD  
(MC16)  
MC16 EXCEPTIONS:  
Broadcast address RT31  
(broadcast not allowed)  
No Status Word transmit.  
Set the Message Error  
(ME) and BCR status bits.  
DBAC bit set.  
BCAST bit set.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
Invalid command word.  
——— OR ———  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word is followed by a  
contiguous data word  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
If broadcast, set the  
BCR status bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
WCTERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
96  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 10001  
and T/R bit equals 0  
Default response: Reset  
Message Error (ME)  
status. and transmit  
DBAC bit reset.  
BCAST bit reset.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
IWA  
Status Word. If broadcast,  
set BCR status bit and  
suppress Status response.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
SYNCHRONIZE  
WITH DATA  
WORD  
(MC17)  
Device stores received data word in the assigned ping-pong or index data buffer (or in Descriptor Word 4  
for SMCP Simplified Mode Command Processing). Configuration Register 2 MCOPT2 and MCOPT3 bits  
allow automatic Time-Tag count loading using the data word received. If MCOPT2 equals 1, the received  
data word is automatically loaded to the Time-Tag counter if the low order bit of the received data word  
(bit 0) equals 0. If MCOPT3 equals 1, the received data word is automatically loaded to the Time-Tag  
counter if the low order bit of the received data word (bit 0) equals 1. If both bits are set, the received  
data word is unconditionally loaded into the Time-Tag counter. For non-broadcast commands, counter  
load occurs before status word transmission.  
MC17 EXCEPTIONS:  
Invalid command word.  
——— OR ———  
T/R bit equals 1 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 1  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
T/R bit equals 1  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word not followed by a  
contiguous data word  
(missing data word)  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
If broadcast, set the  
BCR status bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
WCTERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
Mode code command  
word followed by data  
word with Manchester  
encoding or parity error  
(bad data word)  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
If broadcast, set the  
BCR status bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
IWDERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
97  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 10010  
and T/R bit equals 1  
Default response: Status  
is not updated. Transmit  
Status Word from the  
previous command, with  
data word containing the  
last valid command word  
(assuming it was not a  
“Transmit Status” or a  
“Transmit Last Command”  
mode command.  
DBAC bit reset.  
BCAST bit reset.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERRR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
IWA  
TRANSMIT  
LAST  
COMMAND  
(MC18)  
(All error bits reset.)  
Transmitted data word is  
automatically provided from an  
internal register, and is copied to  
assigned index or ping-pong buffer  
(or to Descriptor Word 4 for SMCP  
Simplified Mode Cmd Processing)  
MC18 EXCEPTIONS:  
Broadcast address RT31  
(broadcast not allowed)  
No Status Word transmit.  
Set the Message Error  
(ME) and BCR status bits.  
DBAC bit set.  
BCAST bit set.  
DPB toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
Invalid command word.  
——— OR ———  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word is followed by a  
contiguous data word  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
If broadcast, set the  
BCR status bit.  
DBAC bit set.  
BCAST updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
WCTERR bit set.  
BUSID bit updated  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
98  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 10011  
and T/R bit equals 1  
Default response: Reset  
Message Error (ME) and  
BCR status bits. then  
DBAC bit reset.  
BCAST bit reset.  
DPB bit toggles.  
Normal CS update:  
BUSID bit reset.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
IWA  
transmit Status Word  
TRANSMIT  
BIT WORD  
(MC19)  
followed by data word from  
either BIT Word Register or  
Alternate BIT Word Register,  
depending on Configuration  
Reg. 2 option bit ALTBITW.  
(All error bits reset.)  
Transmitted data word is  
automatically copied to the  
assigned index or ping-pong buffer  
(or to Descriptor Word 4 for SMCP  
Simplified Mode Cmd Processing)  
MC19 EXCEPTIONS:  
Broadcast address RT31  
(broadcast not allowed)  
No Status Word transmit.  
Set the Message Error  
(ME) and BCR status bits.  
DBAC bit set.  
BCAST bit set.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
Invalid command word.  
——— OR ———  
T/R bit equals 0 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
T/R bit equals 0  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word is followed by a  
contiguous data word  
If broadcast, set the  
BCR status bit.  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
WCTERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
99  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code command  
with mode code 10100  
and T/R bit equals 0  
Default response: Reset  
Message Error (ME)  
status. and transmit  
DBAC bit reset.  
BCAST bit reset.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
IWA  
Status Word. If broadcast,  
set BCR status bit and  
suppress Status response.  
This command is intended  
for use in 1553 systems  
with more than one dual  
redundant bus.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
SELECTED  
TRANSMITTER  
SHUTDOWN  
(MC20)  
After Status Word transmission, the device stores received data word in the assigned  
index or ping-pong buffer (or in Descriptor Word 4 if SMCP Simplified Mode Command  
Processing applies).  
If the MCOPT4 bit in Configuration Register 2 equals 0, the received data word is compared  
to the value in the Bus Select Register corresponding to the inactive bus. For example, if the  
command is received on Bus A, the comparison uses the Bus B Select Register value. If the  
compared values match, the device automatically shuts down either transmit and receive or  
transmit only for the inactive bus, depending on the state of the SDSEL bit in Configuration  
Register 2. (See description of SDSEL and MCOPT4 bits in Configuration Register 2 for further  
information. When a bus transmitter (or transmitter and receiver) is shut down by this mode  
command, bus status is reflected by assertion of a TXASD or TXBSD bit in the Built-In Test  
Register at register address 0x0014. If SDSEL equals logic 0, an RXASD or RXBSD bit will  
also be asserted. See Built-In Test Register description for further information.  
If MCOPT4 bit in Configuration Register 2 equals 1, the IWA interrupt is typically used to alert  
the host when an MC20 command is received. The host must evaluate whether the received  
mode data word matches the bus selection criteria. If bus selection criteria is met, the host  
fulfills bus shutdown command using one of two options:  
(1) set the bus shutdown bit INHBUSA or INHBUSB for the inactive bus in  
Configuration Register 1 to inhibit both transmit and receive,  
or  
(2) assert the transmit shutdown input pin TXINHA or TXINHB for the inactive bus  
to inhibit only transmit. The inactive bus receiver is still active and all valid  
commands are heeded without transmit. This option is rarely applied.  
Once shutdown, the inactive bus transmitter (or transmitter and receiver) can only be  
reactivated by an “Override Transmitter Shutdown” MC5 or MC21 or “Reset Remote Terminal” MC8  
mode code command, or by software reset (by setting the SRST bit in Configuration Register 1)  
or by hardware reset initiated by asserting the MR master reset input pin.  
MC20 EXCEPTIONS:  
Invalid command word.  
——— OR ———  
T/R bit equals 1 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 1  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
MC20 continues on next page  
HOLT INTEGRATED CIRCUITS  
100  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
MC20 EXCEPTIONS  
Continued:  
T/R bit equals 1  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress Status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word not followed by a  
contiguous data word  
(missing data word)  
BCR status bit.  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
WCTERR bit updated.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
If broadcast, set the  
Mode code command  
word followed by data  
word with Manchester  
encoding or parity error  
(bad data word)  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
If broadcast, set the  
BCR status bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
IWDERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
** Command is illegal and terminal is using “illegal command detection”  
Mode code command  
with mode code 10101  
and T/R bit equals 0  
Default response: Reset  
Message Error (ME)  
status. and transmit  
DBAC bit reset.  
BCAST bit reset.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
IWA  
Status Word. If broadcast,  
set the BCR status bit and  
suppress Status response.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
OVERRIDE  
SELECTED  
TRANSMITTER  
SHUTDOWN  
(MC21)  
After Status Word transmission, the device stores received data word in the assigned index or  
ping-pong buffer (or in Descriptor Word 4 if SMCP Simplified Mode Command Processing applies).  
If the MCOPT4 bit in Configuration Register 2 equals 0, the received data word is compared  
to the value in the Bus Select Register corresponding to the inactive bus. For example, if the  
command is received on Bus A, the comparison uses the Bus B Select Register value. If the  
compared values match, the device automatically re-enables transmit and receive for the  
inactive bus, regardless of the state of the SDSEL bit in Configuration Register 2. The device  
affirms fully reenabled bus status by resetting all four TXASD, TXBSD, RXASD and/or RXBSD  
bits in the Built-In Test Register at register address 0x0014. Note: If the TXINHA or TXINHB  
input pins are asserted, the device cannot override the resulting hardware transmit inhibit for  
the affected bus. In this case, the corresponding TXASD and/or TXBSD bits remain high.  
See Built-In Test Register description for further information.  
If MCOPT4 bit in Configuration Register 2 equals 1, the IWA interrupt is typically used to alert  
the host when an MC21 command is received. The host must evaluate whether the received  
mode data word matches the bus selection criteria. If bus selection criteria is met, the host  
fulfills the “override shutdown” command using one of two options:  
(1) reset the bus shutdown bit INHBUSA or INHBUSB for the inactive bus in Configuration  
Register 1 to reenable both transmit and receive, if the host used this bit to shut down  
transmit and receive for an earlier MC4 or MC20 command. (Resetting this shutdown bit  
does not restore bus transmit capability if a TXINHA or TXINHB input pin is asserted.)  
or  
(2) reset the transmit shutdown input pin TXINHA or TXINHB for the inactive bus to reenable  
transmit if the host used this pin to shut down transmit only for an earlier MC4 or MC20 command.  
HOLT INTEGRATED CIRCUITS  
101  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
MC21 EXCEPTIONS:  
Invalid command word.  
——— OR ———  
T/R bit equals 1 and  
UMCINV bit in Config.  
Register 1 equals 1 ***  
No terminal response,  
the message is ignored.  
No Status Word change.  
(mode code is undefined  
when T/R bit equals 0)  
No change.  
No Message Info  
Word is written  
None  
T/R bit equals 1  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 0 *  
Respond “In form”: Reset  
Message Error (ME) status.  
If not broadcast, transmit  
Status Word. If broadcast,  
set the BCR status bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
IWA  
IBR  
T/R bit equals 1  
——— AND ———  
UMCINV bit in Config.  
Register 1 equals 0.  
The Illegalization Table  
bit equals 1 **  
Set Message Error (ME)  
status. If not broadcast,  
transmit Status Word.  
If broadcast, also set  
Status Word BCR bit and  
suppress status response.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
IBR  
Mode code command  
word not followed by a  
contiguous data word  
(missing data word)  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
If broadcast, set the  
BCR status bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
WCTERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
Mode code command  
word followed by data  
word with Manchester  
encoding or parity error  
(bad data word)  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
If broadcast, set the  
BCR status bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
IWDERR bit set.  
BUSID bit updated.  
ILCMD bit reset.  
RTRT bit reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
*** Undefined mode command rendered invalid by UMCINV option bit. Command’s bit in Illegalization Table is “don’t care”.  
HOLT INTEGRATED CIRCUITS  
102  
HI-6120, HI-6121  
RT MESSAGE RESPONSES, OPTIONS & EXCEPTIONS, Cont.  
SUMMARY OF MESSAGE RESPONSES  
FOR THE HI-6120 / HI-6121 REMOTE TERMINAL  
Bits Updated  
in Descriptor  
Control Word  
Bits Updated  
in Data Buffer  
Msg Info Word  
Circumstances for  
Received Message  
Terminal Response  
to Received Command  
Interrupt  
Options  
Mode code commands  
having mode codes  
10110 through 11111  
RESERVED  
MODE CODES  
MC22 - MC31  
The reserved mode code  
commands do not have  
defined actions.  
Host must initialize device  
to respond using either of  
the two following methods:  
The mode code’s bit  
in Illegalization Table  
equals 1 **  
(RT is using “illegal  
command detection”)  
Mode code is illegalized.  
Set Message Error (ME)  
status and transmit Status  
Word. If T/R bit equals 1,  
suppress data word transmission.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
ILCMD bit set.  
MERR bit set.  
BUSID bit updated.  
RTRT bit reset.  
(Other error bits reset.)  
ILCMD  
IWA  
The mode code’s bit  
in Illegalization Table  
equals 0 *  
If T/R bit equals 1,  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset.  
(All error bits reset.)  
—————————  
Normal CS update:  
BUSID bit updated.  
MERR bit reset.  
ILCMD bit reset.  
RTRT bit reset  
(All error bits reset.)  
IWA  
Reset Message Error (ME) status.  
Transmit Status Word with contiguous  
data word read from assigned index or  
ping-pong buffer (or from Descriptor  
Word 4 if the SMCP option applies.)  
—————————  
(RT not using “illegal  
command detection,”  
respond “in form”)  
—————————  
DBAC bit reset.  
BCAST bit updated.  
DPB bit toggles.  
———  
IWA  
IBR  
If T/R bit equals 0,  
Reset Message Error (ME) status  
and transmit Status. If broadcast,  
also set BCR status and suppress  
Status transmit. Device stores received  
data word in assigned index or ping-  
pong buffer (or in Descriptor Word 4  
if SMCP Simplified Mode Command  
Processing applies).  
MC22-MC31 EXCEPTIONS:  
Invalid command word.  
No terminal response,  
the message is ignored.  
No Status Word change.  
No change.  
No Message Info  
Word is written  
None  
.
T/R bit equals 0 and  
mode code command  
word is not followed by  
a contiguous data word  
(missing data word)  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
If broadcast, set the  
BCR status bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
WCTERR bit set.  
BUSID bit updated.  
ILCMD, RTRT bits reset.  
(Other error bits reset.)  
MERR  
IWA  
IBR  
T/R bit equals 0 and  
command word is  
followed by data word  
with Manchester or parity  
error (bad data word)  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
If broadcast, set the  
BCR status bit.  
DBAC bit set.  
BCAST bit updated.  
DPB bit toggles.  
MERR bit set.  
IWDERR bit set.  
BUSID bit updated.  
ILCMD, RTRT bits reset.  
(Other error bits reset.)  
MERR  
IWA  
IBR  
T/R bit equals 1 and  
mode code command  
word is followed by a  
contiguous data word  
No Status Word transmit.  
Set the Message Error  
(ME) status bit.  
DBAC bit set.  
BCAST bit reset.  
DPB bit toggles.  
MERR, WCTERR bits set. MERR  
IWA  
BUSID bit updated.  
ILCMD, RTRT bits reset.  
(Other error bits reset.)  
T/R bit equals 1 and  
mode code command  
is addressed to RT31  
No Status Word transmit.  
Set the Message Error  
(ME) and BCR status bits.  
DBAC bit set.  
BCAST bit set.  
DPB bit toggles.  
MERR bit set.  
MERR  
IWA  
IBR  
BUSID bit updated.  
ILCMD, RTRT bits reset.  
(Other error bits reset.)  
* Command is illegal but terminal is not using “illegal command detection” (in form response).  
** Command is illegal and terminal is using “illegal command detection”  
HOLT INTEGRATED CIRCUITS  
103  
HI-6120, HI-6121  
ABSOLUTE MAXIMUM RATINGS  
RECOMMENDED CONDITIONS  
Operating Supply Voltage  
X
Supply voltage (VDD)  
Logic input voltage range  
Receiver differential voltage  
Driver peak output current  
Power dissipation at 25°C  
Solder Temperature  
-0.3 V to +5.0 V  
-0.3 V DC to +3.6 V  
VDD....................................... 3.3 VDC 5ꢀ  
X
10 Vp-p  
+1.0 A  
Operating Temperature Range  
X
Industrial ......................... -40°C to +85°C  
Extended ....................... -55°C to +125°C  
1.0 W  
275°C for 10 sec.  
175°C  
NOTE: Stresses above absolute maximum ratings or  
outside recommended operating conditions may cause  
permanent damage to the device. These are stress  
ratings only. Operation at the limits is not recommended.  
Junction Temperature  
Storage Temperature  
-65°C to +150°C  
DC ELECTRICAL CHARACTERISTICS  
VDD = 3.3 V, GND = 0V, TA = Operating Temperature Range (unless otherwise specified).  
PARAMETER  
SYMBOL  
VDD  
CONDITION  
MIN  
TYP  
3.30  
4
MAX  
3.45  
10  
UNITS  
V
Operating Voltage  
3.15  
Total Supply Current  
ICC1  
Not Transmitting  
mA  
Transmit one channel @  
50ꢀ duty cycle  
ICC2  
225  
425  
250  
mA  
Transmit one channel @  
100ꢀ duty cycle  
ICC3  
PD1  
PD2  
500  
0.06  
0.5  
mA  
W
Power Dissipation  
Not Transmitting  
Transmit one channel @  
100ꢀ duty cycle  
0.3  
W
Min. Input Voltage  
Max. Input Voltage  
Min. Input Current  
Max. Input Current  
(HI)  
(LO)  
(HI)  
VIH  
VIL  
IIH  
Digital inputs  
Digital inputs  
70ꢀ  
VDD  
VDD  
µA  
30ꢀ  
20  
Digital inputs  
(LO)  
IIL  
Digital inputs  
-20  
µA  
Pull-Up / Pull-Down Current  
Min. Output Voltage (HI)  
Max. Output Voltage (LO)  
IPUD  
VOH  
VIH  
Digital inputs and data bus  
IOUT = -1.0mA, Digital outputs  
IOUT = 1.0mA, Digital outputs  
275  
µA  
90ꢀ  
VDD  
VDD  
10ꢀ  
RECEIVER  
(Measured at Point “AD“ in Figure 25 unless otherwise specified)  
Input resistance  
RIN  
CIN  
Differential  
Differential  
20  
40  
Kohm  
pF  
Input capacitance  
5
Common mode rejection ratio  
Input Level  
CMRR  
VIN  
dB  
Differential  
9
Vp-p  
V-pk  
Vp-p  
Vp-p  
Vp-p  
Vp-p  
Input common mode voltage  
Threshold Voltage - Direct-coupled  
VICM  
VTHD  
VTHND  
VTHD  
VTHND  
-5.0  
5.0  
Detect  
1.15  
20.0  
0.28  
14.0  
0.20  
1 Mhz Sine Wave  
(Measured at Point “AD“ in Fig. 25)  
No Detect  
Threshold Voltage - Transformer-coupled Detect  
No Detect  
0.86  
1 MHz Sine Wave  
(Measured at Point “AT“ in Fig. 26)  
TRANSMITTER  
(Measured at Point “AD” in Figure 25 unless otherwise specified)  
Output Voltage  
VOUT  
35 ohm load  
6.0  
9.0  
Vp-p  
Vp-p  
Direct coupled  
70 ohm load  
(Measured at Point “AT“ in Fig. 26)  
Transformer coupled  
VOUT  
18.0  
27.0  
Output Noise  
VON  
Differential, inhibited  
35 ohm load  
10.0  
90  
mVp-p  
mV  
Output Dynamic Offset Voltage  
VDYN  
-90  
Direct coupled  
70 ohm load  
(Measured at Point “AT“ in Fig. 26)  
Transformer coupled  
VDYN  
-250  
10  
250  
15  
mV  
Output Resistance  
Output Capacitance  
ROUT  
COUT  
Differential, not transmitting  
1 MHz sine wave  
Kohm  
pF  
HOLT INTEGRATED CIRCUITS  
104  
HI-6120, HI-6121  
AC ELECTRICAL CHARACTERISTICS  
VDD = 3.3 V, GND = 0V, TA = Operating Temperature Range (unless otherwise specified).  
LIMITS  
TYP  
PARAMETER  
SYMBOL  
UNITS  
MIN  
MAX  
HI-6121 INTERFACE TIMING (SPI Host Bus Interface)  
SCK clock period  
tCYC  
tCES  
tCEH  
tCPH  
tDS  
50  
25  
25  
100  
10  
10  
25  
25  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
CE set-up time to first SCK rising edge  
CE hold time after last SCK falling edge  
CE inactive between SPI instructions  
SPI SI Data set-up time to SCK rising edge  
SPI SI Data hold time after SCK rising edge  
SCK high time  
tDH  
tSCKH  
tSCKL  
tDV  
SCK low time  
SO valid after SCK falling edge  
SO high-impedance after CE inactive  
20  
75  
tCHZ  
SERIAL INPUT TIMING DIAGRAM  
t CPH  
t CEH  
CE  
tCES  
SCLK  
SI  
tDS  
tDH  
MSB  
LSB  
SERIAL OUTPUT TIMING DIAGRAM  
t CPH  
CE  
tSCKH  
tSCKL  
SCLK  
SO  
t CHZ  
t DV  
MSB  
LSB  
Hi Impedance  
Hi Impedance  
HOLT INTEGRATED CIRCUITS  
105  
HI-6120, HI-6121  
VDD = 3.3 V, GND = 0V, TA = Operating Temperature Range (unless otherwise specified).  
LIMITS  
TYP  
PARAMETER  
SYMBOL  
UNITS  
MIN  
MAX  
HI-6120 INTERFACE TIMING (Parallel Host Bus Interface)  
Clock period  
Write cycle  
tCYC  
tWR  
80  
55  
25  
110  
55  
65  
20  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
Read/Write inactive time  
Non-sequential read time  
8-bit sequential read time  
16-bit sequential read time  
Wait assertion time  
tINACT  
tNSR  
tSR8  
tSR16  
tWAS  
tW  
Wait time  
130  
HOST WRITE IN DUAL-BYTE MODE (8-BIT BUS WIDTH)  
using BTYPE = 1 (”Intel Style” - OE Output Enable and WE Write Enable)  
showing 2 bytes written for a single 16-bit word  
ADDRESS  
A15:1  
A0 LB  
CS  
OE  
tINACT  
OE or WE  
assertion  
for the next  
Read or Write  
tWR  
tWR  
tINACT  
WE  
WAIT  
D7:0  
BYTE 0  
BYTE 1  
HOST WRITE IN WORD MODE (16-BIT BUS WIDTH)  
using BTYPE = 1 (”Intel Style” - OE Output Enable and WE Write Enable)  
showing a one-word write cycle. Successive writes to sequential addresses have same timing.  
ADDRESS  
A15:1  
CS  
OE  
tINACT  
OE or WE  
assertion  
tWR  
WE  
WAIT  
D15:0  
for the next  
Read or Write  
WORD  
All timing intervals equal 0 ns MIN unless otherwise indicated.  
FIGURE 21. Register and RAM Write Operations for BTYPE = 1  
HOLT INTEGRATED CIRCUITS  
106  
HI-6120, HI-6121  
HOST BUS INTERFACE TIMING, Cont. (HI-6120 ONLY)  
HOST WRITE IN DUAL-BYTE MODE (8-BIT BUS WIDTH)  
using BTYPE = 0 (”Motorola Style” - Single Read/Write Strobe STR and R/W Direction Select)  
showing 2 bytes written for a single 16-bit word  
ADDRESS  
A15:1  
A0 LB  
CS  
R / W  
tWR  
tWR  
STR assertion  
for the next  
Read or Write  
tINACT  
tINACT  
STR  
WAIT  
D7:0  
BYTE 0  
BYTE 1  
All timing intervals equal 0 ns MIN unless otherwise indicated.  
HOST WRITE IN WORD MODE (16-BIT BUS WIDTH)  
using BTYPE = 0 (”Motorola Style” - Single Read/Write Strobe STR and R/W Direction Select)  
showing a one-word write cycle. Successive writes to sequential addresses have same timing.  
ADDRESS  
A15:1  
CS  
R / W  
tWR  
STR assertion  
for the next  
Read or Write  
tINACT  
STR  
WAIT  
D15:0  
WORD  
All timing intervals equal 0 ns MIN unless otherwise indicated.  
FIGURE 22. Register and RAM Write Operations for BTYPE = 0  
HOLT INTEGRATED CIRCUITS  
107  
HI-6120, HI-6121  
HOST BUS INTERFACE, Cont. (HI-6120 ONLY)  
HOST READ IN DUAL-BYTE MODE (8-BIT BUS WIDTH)  
using BTYPE = 1 (”Intel Style” - OE Output Enable and WE Write Enable)  
showing two bytes read for a single 16-bit word  
ADDRESS  
A15:1  
A0 LB  
CS  
WE  
tINACT  
WE or OE  
assertion  
for the next  
Write or Read  
tNSR  
tSR8  
tINACT  
OE  
WAIT  
D7:0  
tWAS  
tW  
BYTE 0  
BYTE 1  
High-Z  
High-Z  
High-Z  
All timing intervals equal 0 ns MIN unless otherwise indicated.  
After first byte is read, prefetch allows faster access times for successive reads, as long as addresses are sequential.  
WAIT is always asserted during the first read cycle, is never asserted for successive read cycles to sequential adresses.  
This allows default host bus configuration for the HI-6120 chip select to match the timing characteristics of the faster  
successive cycles, while the slower initial cycle is handled on a WAIT-controlled exception basis. WAIT can be optionally inverted.  
HOST READ IN WORD MODE (16-BIT BUS WIDTH)  
using BTYPE = 1 (”Intel Style” - OE Output Enable and WE Write Enable)  
showing two successive words read from sequential addresses  
ADDRESS  
ADDRESS + 1  
A15:1  
CS  
WE  
OE  
tINACT  
WE or OE  
assertion  
for the next  
Write or Read  
tNSR  
tSR16  
tINACT  
tWAS  
WAIT  
D15:0  
tW  
WORD  
WORD  
High-Z  
High-Z  
High-Z  
All timing intervals equal 0 ns MIN unless otherwise indicated.  
After first word is read, prefetch allows faster access times for successive reads, as long as addresses are sequential.  
WAIT is always asserted during the first read cycle, is never asserted for successive read cycles to sequential adresses.  
This allows default host bus configuration for the HI-6120 chip select to match the timing characteristics of the faster  
successive cycles, while the slower initial cycle is handled on a WAIT-controlled exception basis. WAIT can be optionally inverted.  
FIGURE 23. Register and RAM Read Operations for BTYPE = 1  
HOLT INTEGRATED CIRCUITS  
108  
HI-6120, HI-6121  
HOST BUS INTERFACE, Cont. (HI-6120 ONLY)  
HOST READ IN DUAL-BYTE MODE (8-BIT BUS WIDTH)  
using BTYPE = 0 (”Motorola Style” - Single Read/Write Strobe STR and R/W Direction Select)  
showing two bytes read for a single 16-bit word  
ADDRESS  
A15:1  
A0 LB  
CS  
R / W  
tINACT  
tNSR  
tSR8  
STR assertion  
for the next  
Read or Write  
tINACT  
STR  
WAIT  
D7:0  
tWAS  
tW  
BYTE 0  
BYTE 1  
High-Z  
High-Z  
High-Z  
All timing intervals equal 0 ns MIN unless otherwise indicated.  
After first byte is read, prefetch allows faster access times for successive reads, as long as read addresses are sequential.  
WAIT is always asserted during the first read cycle, is never asserted for successive read cycles to sequential adresses.  
This allows default host bus configuration for the HI-6120 chip select to match the timing characteristics of the faster  
successive cycles, while the slower initial cycle is handled on a WAIT-controlled exception basis. WAIT can be optionally inverted.  
HOST READ IN WORD MODE (16-BIT BUS WIDTH)  
using BTYPE = 0 (”Motorola Style” - Single Read/Write Strobe STR and R/W Direction Select)  
showing two successive words read from sequential addresses  
ADDRESS  
ADDRESS + 1  
A15:1  
CS  
R / W  
STR  
tINACT  
tNSR  
tSR16  
tINACT  
STR assertion  
for the next  
Read or Write  
tWAS  
WAIT  
D15:0  
tW  
WORD  
WORD  
High-Z  
High-Z  
High-Z  
All timing intervals equal 0 ns MIN unless otherwise indicated.  
After first word is read, prefetch allows faster access times for successive reads, as long as read addresses are sequential.  
WAIT is always asserted during the first read cycle, is never asserted for successive read cycles to sequential adresses.  
This allows default host bus configuration for the HI-6120 chip select to match the timing characteristics of the faster  
successive cycles, while the slower initial cycle is handled on a WAIT-controlled exception basis. WAIT can be optionally inverted.  
FIGURE 24. Register and RAM Read Operations for BTYPE = 0  
HOLT INTEGRATED CIRCUITS  
109  
HI-6120, HI-6121  
MIL-STD-1553 BUS INTERFACE  
TRANSMITTER  
BUSA/B  
1:2.5  
55 W  
55 W  
Tx Data from  
Manchester  
Encoder  
35 W  
Point “AD“  
BUSA/B  
Isolation  
Transformer  
TXINHA/B  
RECEIVER  
2.5:1  
55 W  
55 W  
Rx Data to  
Manchester  
Decoder  
Point “AD“  
35 W  
Isolation  
Transformer  
Figure 25. Direct Coupled Test Circuits  
Point  
“AT”  
TRANSMITTER  
52.5 W  
(.75 Zo)  
1:2.5  
1:1.4  
BUSA/B  
Tx Data from  
Manchester  
Encoder  
35 W (.5 Zo)  
BUSA/B  
52.5 W  
(.75 Zo)  
Isolation  
Transformer  
Coupling  
Transformer  
TXINHA/B  
Point  
“AT”  
RECEIVER  
52.5 W  
(.75 Zo)  
1.4:1  
2.5:1  
Rx Data to  
Manchester  
Decoder  
35 W (.5 Zo)  
52.5 W  
(.75 Zo)  
Coupling  
Transformer  
Isolation  
Transformer  
Figure 26. Transformer Coupled Test Circuits  
HOLT INTEGRATED CIRCUITS  
110  
HI-6120, HI-6121  
THERMAL CHARACTERISTICS  
Data taken at VDD = 3.3V, continuous data transmission at 1 Mbit/s, single transmitter enabled.  
JUNCTION TEMPERATURE  
TA= 25°C TA= 85°C TA= 125°C  
PART NUMBER  
PACKAGE STYLE  
100 pin PQFP  
CONDITION  
qJA  
Mounted on  
circuit board  
52.7  
°C / W  
HI-6120PQx  
HI-6121PQx  
56°C  
56°C  
116°C  
116°C  
156°C  
156°C  
Mounted on  
circuit board  
60.9  
°C / W  
52 pin PQFP  
Heat sink pad  
unsoldered  
31.1  
°C / W  
41°C  
37°C  
101°C  
97°C  
141°C  
137°C  
64 pin QFN  
HI-6121PCx  
Heat sink pad  
soldered  
22.8  
°C / W  
PIN CONFIGURATION FOR HI-6121, 64-PIN QFN PACKAGE  
Notes  
1 . All VCC, VCCP and GND pins must be connected.  
2. See data sheet page 1 for HI-6121, 52-Pin PQFP Package Configuration.  
GND  
COMP  
CE  
1
2
3
4
5
6
7
8
9
48 BENDI  
47 TEST  
46 LOCK  
45 MTSTOFF  
44 BUSA  
43 VCCP  
42 VCCP  
41 BUSA  
40 BUSB  
39 VCCP  
38 VCCP  
37 BUSB  
36 TEST0  
35 TEST1  
34 TEST2  
33 TEST3  
MODE  
SI  
SCK  
SO  
VCC  
MCLK  
HI-6121PCx  
GND 10  
RTA0 11  
RTA1 12  
RTA2 13  
MR 14  
RTA3 15  
RTA4 16  
TOP VIEW  
HOLT INTEGRATED CIRCUITS  
111  
HI-6120, HI-6121  
PIN CONFIGURATION FOR HI-6120, 100-PIN PQFP PACKAGE  
Notes  
1 . All VCC, VCCP and GND pins must be connected.  
2. See data sheet page 1 for HI-6121, 52-Pin PQFP Package Configuration.  
75 - D1  
74 - D0  
VCC - 1  
GND - 2  
D12 - 3  
73 - BENDI  
72 - TEST  
71 - LOCK  
70 - MTSTOFF  
69 - BUSA  
68 - BUSA  
67 - VCCP  
66 - VCCP  
65 - BUSA  
64 - BUSA  
63 - BUSB  
62 - BUSB  
61 - VCCP  
60 - VCCP  
59 - BUSB  
58 - BUSB  
57 - TEST0  
56 - TEST1  
55 - TEST2  
54 - TEST3  
53 - BWID  
52 - WPOL  
51 - A15  
D13 - 4  
D14 - 5  
D15 - 6  
COMP - 7  
CE - 8  
MODE - 9  
STR - 10  
VCC - 11  
BTYPE - 12  
MCLK - 13  
GND - 14  
WAIT - 15  
R / W - 16  
RTA0 - 17  
RTA1 - 18  
RTA2 - 19  
MR - 20  
HI-6120PQx  
RTA3 - 21  
RTA4 - 22  
A0 - 23  
A1 - 24  
A2 - 25  
TOP VIEW  
HOLT INTEGRATED CIRCUITS  
112  
HI-6120, HI-6121  
ORDERING INFORMATION  
HI-6120PQ x x  
PART PACKAGE  
NUMBER DESCRIPTION  
Blank  
F
Tin / Lead (Sn / Pb) Solder  
100ꢀ Matte Tin (Pb-free RoHS compliant)  
PART TEMPERATURE  
NUMBER RANGE  
BURN  
IN  
FLOW  
I
-40°C TO +85°C  
I
No  
No  
T
M
-55°C TO +125°C  
-55°C TO +125°C  
T
M
Yes  
PART PACKAGE  
NUMBER DESCRIPTION  
PQ  
100 PIN PLASTIC QUAD FLAT PACK PQFP (100PQS)  
HI-6121PQ x x  
PART PACKAGE  
NUMBER DESCRIPTION  
Blank  
F
Tin / Lead (Sn / Pb) Solder  
100ꢀ Matte Tin (Pb-free RoHS compliant)  
PART TEMPERATURE  
NUMBER RANGE  
BURN  
IN  
FLOW  
I
-40°C TO +85°C  
I
No  
No  
T
M
-55°C TO +125°C  
-55°C TO +125°C  
T
M
Yes  
PART PACKAGE  
NUMBER DESCRIPTION  
PC  
PQ  
64 PIN PLASTIC 9 x 9mm CHIP SCALE LPCC (64PCS)  
52 PIN PLASTIC QUAD FLAT PACK PQFP (52PTQS)  
HOLT INTEGRATED CIRCUITS  
113  
HI-6120, HI-6121  
REVISION HISTORY  
Document Rev. Date  
Description of Change  
DS6120 New 11/24/09 Initial Release.  
HOLT INTEGRATED CIRCUITS  
114  
HI-6120 & HI-6121 PACKAGE DIMENSIONS  
52-PIN PLASTIC QUAD FLAT PACK (PQFP)  
inches (millimeters)  
Package Type: 52PTQS  
.0256  
(.65)  
BSC  
.520  
(13.2)  
.394  
(10.0)  
BSC SQ  
BSC SQ  
.015 .003  
(.375 .075)  
.035 .006  
(.88 .15)  
.063  
(1.6)  
typ  
.008  
(.20)  
min  
See Detail A  
.005  
(.13)  
R min  
.063  
(1.6)  
MAX.  
.055 .002  
(1.4 .05)  
£ Q £ 7°  
.005  
(.13)  
R min  
BSC = “Basic Spacing between Centers”  
is theoretical true position dimension and  
has no tolerance. (JEDEC Standard 95)  
DETAIL A  
64-PIN PLASTIC CHIP-SCALE PACKAGE (QFN)  
inches (millimeters)  
Package Type: 64PCS  
Heat sink pad on bottom of package.  
Heat sink must be left floating or  
connected to VDD.  
DO NOT connect to GND.  
.354  
BSC  
.281 .003  
(7.125 .075)  
(9.00)  
.0197  
(0.50)  
BSC  
typ  
.354  
(9.00)  
.281 .003  
(7.125 .075)  
BSC  
Top View  
Bottom  
View  
.010  
(0.25)  
.016 .004  
(0.40 .10)  
.008  
(0.20)  
typ  
BSC = “Basic Spacing between Centers”  
is theoretical true position dimension and  
has no tolerance. (JEDEC Standard 95)  
.039  
(1.00)  
max  
HOLT INTEGRATED CIRCUITS  
115  
HI-6120 & HI-6121 PACKAGE DIMENSIONS  
100-PIN PLASTIC QUAD FLAT PACK (PQFP)  
inches (millimeters)  
Package Type: 100PQS  
.0197  
(0.50)  
BSC  
.630  
(16.0)  
.551  
(14.0)  
BSC SQ  
BSC SQ  
.009 .002  
(.22 .05)  
.024 .006  
(.60 .15)  
.039  
(1.0)  
typ  
.008  
(0.20)  
min  
See Detail A  
.008  
(0.20)  
R max  
.059 .004  
(1.50 .10)  
.055 .002  
(1.40 .05)  
£ Q £ 7°  
BSC = “Basic Spacing between Centers”  
is theoretical true position dimension and  
has no tolerance. (JEDEC Standard 95)  
.003  
(0.08)  
R min  
Detail A  
HOLT INTEGRATED CIRCUITS  
116  

相关型号:

HI-6121PQIF

MIL-STD-1553 Remote Terminal ICs
HOLTIC

HI-6121PQM

MIL-STD-1553 Remote Terminal ICs
HOLTIC

HI-6121PQMF

MIL-STD-1553 Remote Terminal ICs
HOLTIC

HI-6121PQT

MIL-STD-1553 Remote Terminal ICs
HOLTIC

HI-6121PQTF

MIL-STD-1553 Remote Terminal ICs
HOLTIC

HI-6130

3.3V BC / MT / RT Multi-Terminal Device
HOLTIC

HI-6131

3.3V BC / MT / RT Multi-Terminal Device
HOLTIC

HI-6132

3.3V BC / MT / RT Multi-Terminal Device
HOLTIC

HI-6140

10 MBit/s MIL-STD-1553 3.3V BC / MT / RT
HOLTIC

HI-674A

Complete, 12-Bit A/D Converters with Microprocessor Interface
INTERSIL

HI-674A/883

Complete. 12-Bit A/D Converters with Microprocessor Interface
ETC

HI-7151

10-Bit, High Speed, A/D Converter with Track and Hold
INTERSIL