PB-600 [MEANWELL]
600W Single Output Battery Charger; 600W单路输出充电器型号: | PB-600 |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 600W Single Output Battery Charger |
文件: | 总5页 (文件大小:441K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
600W Single Output Battery Charger
PB-600 series
Features :
2/3/8 stage charging (Note 4)
Universal AC input / Full range
Built-in active PFC function PF>0.95
Protection: Reverse polarity / Short circuit / Over voltage / Over temperature
Charger for lead-acid batteries
3 color LED loading indicator
Built-in remote ON-OFF control
Built-in temperature compensation function
Built-in fan speed control (depends on charging current)
3 years warranty
..
SPECIFICATION
MODEL
PB-600-12
PB-600-24
PB-600-48
BOOST CHARGE VOLTAGE 14.4V
28.8V
27.6V
57.6V
55.2V
FLOAT CHARGE VOLTAGE 13.8V
RECOMMENDED BATTERY
OUTPUT
135 ~ 400AH
70 ~ 210AH
35 ~ 105AH
CAPACITY(AMP HOURS)(Note 3)
BATTERY TYPE
Open & Sealed Lead Acid
40A
OUTPUT CURRENT
21A
10.5A
VOLTAGE RANGE
90 ~ 264VAC
47 ~ 63Hz
127 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
86%
87%
89%
POWER FACTOR (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.95/230VAC
6.8A/115VAC
25A/115VAC
<3.5mA / 240VAC
16 ~ 18V
0.98/115VAC at full load
3.4A/230VAC
INPUT
50A/230VAC
LEAKAGE CURRENT
32 ~ 35V
64.5 ~ 69.5V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
PROTECTION
OVER TEMPERATURE
REMOTE CONTROL
LEAKAGE CURRENT FROM BATTERY (Typ.)
FAST CHARGE
Open: Normal work
1mA
Short: Stop Charging
2 / 3 / 8 stage selectable
Relay contact (RY15)
Relay contact (RY13)
By NTC
FUNCTION
CHARGING OK
OUTPUT OK
TEMPERATURE SENSE
WORKING TEMP.
-20 ~ +60 (refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
-40 ~ +85 , 10 ~ 95% RH
0.05%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL1012, TUV EN60335-1, EN60335-2-29 (except for 48V), EN60950-1(48V only) approved
I/P-O/P:3KVAC I/P-FG:1.8KVAC O/P-FG:0.5KVAC
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SAFETY &
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
(Note 2)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024; light industry level, criteria A
135.6Khrs min. MIL-HDBK-217F (25
230*158*67mm(L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
2.2Kg; 6pcs/14.2Kg/1.76CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
3. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
4. Please choose the "3 stage" selection when the charger is used to charge the batteries and power the loads in the same time.
File Name:PB-600-SPEC 2011-04-20
600W Single Output Battery Charger
PB-600 series
Mechanical Specification
Case No.805C
Unit:mm
230
145
42.5
67
7
ON/OFF
SWITCH
INLET
Air flow
direction
48
24.1
Control Pin No. Assignment(CN100) : HRS DF11-10DP-2DS or equivalent
Pin No. Assignment Pin No. Assignment Mating Housing
Terminal
RY13
NC
NTC(5K
RC-
)
1,2
3,4
5,6
7
8
9
HRS DF11-10DS HRS DF11-**SC
or equivalent or equivalent
RY15
GND
10
RC+
RY13 : Battery bank OK
RY15 : Charging OK
NTC / GND : Temperature sense
RC+ / RC-: Remote ON/OFF
Charging Curve
2 Stage
3 Stage
Start
Start
Vboost
Vboost
Vfloat
Charge Voltage
Charge Voltage
100%
100%
10%
10%
Charge Current
Color of LED
Charge Current
Color of LED
Constant Current Constant Voltage
Constant Current Constant Voltage
stage 1 stage 2
Float
stage 1
stage 2
stage 3
Green
Orange
Green
Orange
File Name:PB-600-SPEC 2011-04-20
600W Single Output Battery Charger
PB-600 series
8 Stage
Pulse
Soft Start
Analysis
Recond
Float
Maintain
Constant Current Constant Voltage
Charge Voltage
Charge Current
stage 1
stage 2
stage 3
stage 4
stage 5
stage 6
stage 7
stage 8
Orange
Green
Color of LED
Block Diagram
PFC : 95KHz
PWM fosc : 60KHz
ACTIVE
RECTIFIER
RECTIFIER
&
FILTER
POWER
EMI
FILTER
INRUSH
CURRENT
LIMITING
+V
I/P
&
PFC
SWITCHING
PFC
CONTROL
REVERSE
DETECTION
PWM
CONTROL
CURRENT
DETECTION
MCU
2/8
STAGE
SELECT
AUX
POWER
FAN
OTP
REMOTE
CONTROL
RC
Bank OK
RY13
RY15
Charging OK
Derating Curve
Static Characteristics
Ta=25
100
90
100
80
80
70
60
40
60
50
40
20
90
95
100
115
264
-20
0
10
20
30
40
50
60
70
(HORIZONTAL)
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (VAC) 60Hz
File Name:PB-600-SPEC 2011-04-20
600W Single Output Battery Charger
PB-600 series
Function Description of CN100
The Function of LEDs
Battery
Fail
Color of LED
Red
Pin No. Function
Description
Relay contact rating(max.) : 30V/1A resistive. ; "Short" when the battery is full,
"Open" when the battery is still charging
1,2
5,6
7,8
RY13
RY15
Charging
Orange
Green
Battery Full
Relay contact rating(max.) : 30V/1A resistive. ; "Short" when the unit is working properly,
"Open" when the unit stop charging
Temperature sensor comes along with the charger can be connected to the unit to allow
temperature compensation of the charging voltage
GND / RTH
Turn the output on and off by electrical or dry contact between pin 10 (RC+) and pin 9(RC-)
Open : Normal work , Short : Stop charging
9,10 RC- / RC+
Function Manual
1.Remote Control
The charger can be turned ON/OFF by using the
"Remote Control" function.
CN100
2
1
RY13 RY13
NC NC
Between RC+(pin10) and RC-(pin9)
Charging
Power
Stage 8/3/2
SW Open
SW Short
ON
RY15 RY15
GND RTH
RC- RC+
OFF
1
3
5
7
9
2
4
6
8
10
10
9
SW
+
-
Battery
CN100
2. 2,3, or 8 stage charging select
2
1
RY13 RY13
(1)The charger features user selectable 2,3, or 8 stage charging.
The charging profile is selected by moving the slide switch
on the back panel.
NC NC
RY15 RY15
GND RTH
RC- RC+
Power
Stage 8/3/2
Switch
Right
Middle
Left
Charging mode
2 stage charging
3 stage charging
8 stage charging
1
3
5
7
9
2
4
6
8
10
10
9
+
-
(2)Please choose the "3 stage" selection when the charger
is used to charge the batteries and power the loads in the
same time.
Battery
3.Charger OK Relay(RY15)
CN100
Charger
Between pin5 and pin6(RY15)
ON (Short)
2
1
RY13 RY13
Power
Stage 8/3/2
Normal work
NC NC
RY15 RY15
GND RTH
RC- RC+
Failure or the protection
function is activating
OFF (Open)
1
3
5
7
9
2
4
6
8
10
10
9
+
-
RY15
Battery
File Name:PB-600-SPEC 2011-04-20
600W Single Output Battery Charger
PB-600 series
4.Output OK (RY13)
1.Bank OK (RY13)
CN100
2
1
Bank
Between pin1 and pin2(RY13) Color of LED
RY13 RY13
NC NC
Power
Stage 8/3/2
Battery Full
Charging
ON (Short)
Green
OFF (Open)
Orange
RY15 RY15
GND RTH
RC- RC+
1
3
5
7
9
2
4
6
8
10
10
9
RY13
+
-
Battery
5.Temperature compensation
CN100
Temperature sensor comes along with the charger can
2
1
RY13 RY13
be connected to the unit to allow temperature compensation
of the charging voltage.
Power
Stage 8/3/2
NC NC
RY15 RY15
GND RTH
RC- RC+
If the sensor is not used, the charger still works normally.
1
3
5
7
9
2
4
6
8
10
10
9
+
-
Battery
NTC
The temperature sensor can either be attached to
the battery or placed in its surrounding environment.
File Name:PB-600-SPEC 2011-04-20
相关型号: