PSC-100B [MEANWELL]
100W Single Output with Battery Charger(UPS Function); 100W单路输出带电池充电器( UPS功能)型号: | PSC-100B |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 100W Single Output with Battery Charger(UPS Function) |
文件: | 总3页 (文件大小:864K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
100W Single Output with Battery Charger(UPS Function)
PSC-100 series
Features :
Universal AC input / Full range
5"x3" compact size
Optional L-Bracket and cover (PSC-100x-C, x=A,B)
Protections: Short circuit / Overload / Over voltage
Battery low protection / Battery polarity protection by fuse
Relay contact signal output for AC OK and Battery Low
Cooling by free air convection
100% full load burn-in test
2 years warranty
SPECIFICATION
MODEL
PSC-100A
PSC-100B
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
13.8V
4.75A
0 ~ 7A
100.05W
13.8V
2.5A
27.6V
27.6V
1.25A
--------
RATED CURRENT
CURRENT RANGE
RATED POWER
2.4A
--------
0 ~ 3.5A
100.74W
100mVp-p
CH1: 24 ~ 29V
1.0%
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 1.0%
--------
--------
OUTPUT
CH1: 12 ~ 15V
--------
--------
--------
--------
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
0.5%
--------
0.5%
0.5%
--------
0.5%
Note.5 2400ms, 30ms/230VAC
2400ms, 30ms/115VAC at full load
40ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
86%
16ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
88%
INPUT
2A/115VAC
1.2A/230VAC
COLD START 35A/115VAC
<1mA / 240VAC
70A/230VAC
LEAKAGE CURRENT
105 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:14.49 ~ 18.63V
CH1:28.98 ~ 37.26V
PROTECTION
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
10 0.5V
20 1V
BATTERY CUT OFF
Relay contact output, ON : AC OK ; OFF : AC Fail ; Max. rating : 30V / 1A
Note.6
AC OK
ALARM
Relay contact output, OFF : Battery OK ; ON : Battery Low ; Max. rating : 30V / 1A
FUNCTION
BATTERY LOW
Battery low voltage : < 11V
Battery low voltage : < 22V
-20 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0~50 ) on CH1 output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
SAFETY &
EMC
(Note 4)
EMC IMMUNITY
MTBF
417.6K hrs min. MIL-HDBK-217F (25
)
PCB:127*76.2*31mm (L*W*H) ; with optional CASE:130*85*37mm (L*W*H)
OTHERS
NOTE
DIMENSION
PCB:0.23Kg; 63pcs/15.5Kg/1.35CUFT ; with optional CASE:0.44Kg;32pcs/15Kg/0.64CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Please refer to suggest application (2) (4) in page 3.
7. Heat sink HS2,HS3 can not be shorted.
8. Heat sink HS2,HS3 must have safety isolation distance from system case.
File Name:PSC-100-SPEC 2011-08-18
100W Single Output with Battery Charger(UPS Function)
PSC-100 series
Mechanical Specification
Unit:mm
Optional cover:
No. 946B-T
CN2
AC FUSE
T3.15A/250V
1
2
3
4
5
6
7
8
FS1
3
2
1
CN1
1
2
3
4
CN3
SVR1
HS2
HS3
115.8
127
5.6
Mylar film
8
1
7
.
1
2
-
M
3 L
=
4
1
1
5
.
8
2
-
M
3
7
3
6
-
M
3 L
=
4
2
.
8
7
.
1
4
7
8
6
.
8
1
3
5
6
6
0
2
8
Optional L-Bracket:
No. 946A-D
2
6
1
7
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. Assignment
Mating Housing
Terminal
Alarm Output Connector(CN3) : JST B4B-XH or equivalent
1
2
3
AC/N
No Pin
AC/L
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
Pin No. Assignment
Mating Housing
Terminal
1
3
2
4
AC OK
JST SXH-001T-P0.6
or equivalent
JST XHP
or equivalent
DC Output Connector (CN2) : JST B8P-VH or equivalent
Bat. Low
Pin No. Assignment
Mating Housing
Terminal
1,2
3,4
5,6
7,8
-V
+V
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
1.HS2,HS3 can not be shorted.
2.HS2,HS3 must have safety isolation distance from system case.
3.-V and Bat- can not be shorted.
Bat+
Bat-
Block Diagram
AC OK
RL1
RL2
ALARM
CIRCUIT
Bat. Low
EMI FILTER
&
RECTIFIER
RECTIFIERS
POWER
+V
I/P
FG
&
SWITCHING
-V
FILTER
Bat. +
DETECTION
Bat. -
CIRCUIT
PWM
CONTROL
Battery Charger
&
Back up Control
O.L.P.
O.V.P.
File Name:PSC-100-SPEC 2011-08-18
100W Single Output with Battery Charger(UPS Function)
PSC-100 series
Output Derating
Output Derating VS Input Voltage
100
90
100
80
PCB only
PCB only
For PCB with
80
For PCB with L-Bracket+cover option
L-Bracket+cover option
60
50
40
70
60
50
40
20
(HORIZONTAL)
70
-20
0
10
20
30
40
50
60
90 95 100 115 120 140 160 180 200 220 240 264
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (VAC) 60Hz
Suggested Application
1.Back up connection for AC interruption
(1) Please refer to the Fig1.1 for suggested connection.
The power supply charge the battery and provide energy to the load in the same time when the AC main is OK.
The battery start to supply power to the load when the AC main fails.
-V
-
Load
+V
+
Bat+
Bat-
A : 12V
B : 24V
+
-
Battery
Fig 1.1 Suggested system connection
2.Alarm signal for AC OK and Battery Low
(1) Alarm signal is sent out through " AC OK " & " Battery Low " pins.(relay contact type)
(2) An external voltage source is required for this function. The maximum applied voltage is 30V and the maximum sink current is 1A.
(3) Table2.1 explain the alarm function built-in the power supply
AC OK (Battery low)
CN3 Pin1(Pin3)
Function
Description
Output of Alarm
Low or short
The signal is "Low" when the power supply
turns on
AC OK
High or open(External applied
voltage 30V max.)
The signal turns to be "High" when the power
supply turns OFF
R
V
The signal is "Low" when the voltage of
battery is under A:11V, B:22V
Low or short
Battery
Low
High or open(External applied
voltage 30V max.)
The signal is "High" when the voltage of
battery is above A:11V, B:22V
CN3 Pin2(Pin4)
External voltage source (V)
and resistor (R)
Table 2.1 Explanation of Alarm Signal
(The max. Sink is 1A and 30V)
Fig 2.2 Internal circuit of AC OK (Battery Low)
(4) RL1 (AC OK)signal will go into hiccup mode when the overload protection is activating.
File Name:PSC-100-SPEC 2011-08-18
相关型号:
PSC-12-1+
Combiner, 1MHz Min, 200MHz Max, 1.4dB Insertion Loss-Max, ROHS COMPLIANT, CASE E10, 32 PIN
MINI
©2020 ICPDF网 联系我们和版权申明