RCP-1U [MEANWELL]
UNIVERSAL AC INPUT / FULL RANGE;型号: | RCP-1U |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | UNIVERSAL AC INPUT / FULL RANGE 输入元件 |
文件: | 总6页 (文件大小:232K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
1000 ~ 3000W 1U Distributed Power System
RCP-1U Rack System
Rack Dimension
L
*
W
*
H
Bauart gepruft
Sicherheit
483.6 * 350.8 * 44 (1U) mm
19 1.73(1U) inch
egelma ge
o s
g
od
be wac
www.tuv.com
ID 2000000000
*
*
13.8
■ Features
■ Applications
ꢀUniversal AC input / Full range
ꢀ1U profile 19” rack shelf, fitting three 1000W modules
up to 3000W with active current sharing
ꢀOutput voltage programmable
ꢀSupport hot swap (hot plug)
ꢀIndustrial automation
ꢀDistributed power architecture system
ꢀWireless/telecommunication solution
ꢀRedundant power system
ꢀElectric vehicle charger system
ꢀConstant current source system
ꢀ5 years warranty
■ Description
RCP-1U rack system is a power distribution solution utilizing the rack configuration with 1U low profile.
Starting with a single unit of 1000W, RCP-1000 is the front end rectifier (or, power supply). With the active
current sharing function, up to 3000W is able to be provided by 1 stack of the 19” rack mountable shelf
RCP-1U and 8000W by 3 stacks. The design flexibility for system applications is ideally fulfilled by various
built-in features, such as output programming, remote ON-OFF, auxiliary power, etc.
■ Model Encoding / Order Information
Rack Shelf:
RCP-1U I
Whole System:
RCP-3K1U I -12 - C
C: With I2C Interface
: Without I2C Interface
Output voltage
I: AC Inlet (IEC320-C14)
T: Terminal block
Profile of the system
Series name
I: AC Inlet (IEC320-C14)
T: Terminal block
1U: Profile of the system
3K: Maximum wattage with
fully-populated shelf
Series name
File Name:RCP-1U Rack System-SPEC 2016-07-26
1000 ~ 3000W 1U Distributed Power System
RCP-1U Rack System
SPECIFICATION - Power Supply System
MODEL
RCP-3K1U□-12
RCP-3K1U□-24
RCP-3K1U□-48
RECTIFIER
RCP-1000-12
RCP-1UI or RCP-1UT
12V
RCP-1000-24
RCP-1000-48
RACK SHELF
OUTPUT VOLTAGE
MAX. OUTPUT CURRENT
24V
48V
OUTPUT
180A
120A
2880W
63A
MAX. OUTPUT POWER Note.6 2160W
3024W
VOLTAGE RANGE
Note.5 90 ~ 264VAC
127 ~ 370VDC
4.5A/230VAC
FREQUENCY RANGE
AC CURRENT (Typ.)PER MODULE
LEAKAGE CURRENT
AUXILIARY POWER
47 ~ 63Hz
INPUT
8.5A/115VAC
<3.5mA / 230VAC
5V @ 0.3A
10.5A/115VAC
5.5A/230VAC
11A/115VAC
5.5A/230VAC
By electrical signal or dry contact ON:short OFF:open
Compensate voltage drop on the load wiring up to 0.5V.
REMOTE ON-OFF CONTROL
REMOTE SENSE
Adjustment of output voltage is allowable to 90 ~ 110% of nominal output voltage. Please refer to the Function Manual.
The isolated TTL signal out, Please refer to the Installation Manual
The isolated TTL signal out, Please refer to the Installation Manual
Logic " High" for over temperature warning, Please refer to the Installation Manual, isolated signal
-20 ~ +60℃ (Refer to "Derating Curve")
OUTPUT VOLTAGE PROGRAMMABLE
DC OK SIGNAL
FUNCTION
AC OK SIGNAL
OVER TEMP WARNING
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH
ENVIRONMENT
TEMP. COEFFICIENT
VIBRATION
0.02%/℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.7KVDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Standard
Test Level / Note
Conducted
EN55022 (CISPR22) / EN55011 (CISPR11) Class B
EN55022 (CISPR22) / EN55011 (CISPR11) Class B
Radiated
EMC EMISSION
Harmonic Current
Voltage Flicker
EN55024 , EN61204-3, EN61000-6-2
Parameter
EN61000-3-2
EN61000-3-3
-----
-----
SAFETY &
Standard
Test Level / Note
EMC
(Note 4)
ESD
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Level 3, 8KV air ; Level 2, 4KV contact
Radiated
Level 3
EFT / Burst
Level 3
EMC IMMUNITY
Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line
Surge
Conducted
Level 3
Level 4
Magnetic Field
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Voltage Dips and Interruptions
EN61000-4-11
DIMENSION
PACKING
Rack 483.6*350.8*44(L*W*H)
13.2Kg; 1pcs/13.2Kg/2.67CUFT
OTHERS
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Under parallel
operation of more than one rack connecting together, ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to
normal ripple level once the output load is more than 10%. .
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Output of all the RCP-1000 modules are connected in parallel in the rack.
File Name:RCP-1U Rack System-SPEC 2016-07-26
1000 ~ 3000W 1U Distributed Power System
RCP-1U Rack System
Function Manual
1. Remote ON/OFF Control
The PSU can be turned ON/OFF together or separately by using the "Remote ON-OFF" function.
1
8
15
1
8
15
Remote ON-OFF A
Remote ON-OFF B
Remote ON-OFF C
Remote ON-OFF A
Remote ON-OFF B
Remote ON-OFF C
Between Remote ON-OFF and -S Output
RCP-1U
System
RCP-1U
System
Switch Open
Switch Short
OFF
ON
21
21
-S
-S
2. Voltage Drop Compensation
2.1 Remote Sense
The remote sense compensates voltage drop on the load wiring up to 0.5V.
+V
+S
+V
20
21
RCP-1U System
LOAD
-S
-V
-V
Sense lines should be twisted in pairs
2.2 Local Sense
Notice : The +S,-S, on CN500 have to be connected to the +V,-V terminals locally in order to get the correct output voltage if the remote sensing is not used.
22
+V
20
+S
RCP-1U System
25
21
-V
-S
3. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
(1)Output voltage can be trimmed between 90~110% of its rated value by the following method.
(2)+S & +V, -S & -V also need to be connected on CN500.
22
+V
+S
20
4
R1
R2
R1
R2
R1
R2
V-TRIM-A
V-TRIM-B
V-TRIM-C
11
18
RCP-1U System
LOAD
21
25
-S
-V
3.1 RCP-1000-12
Vout (%)
Vout (%)
100
98
96
94
92
90
110
108
106
104
102
100
R1 (Ω)
min. 0.1W
R2 (Ω)
min. 0.1W
180K
240K
350K
560K
1.2M
NC
NC
300K
120K
62K
31K
13K
File Name:RCP-1U Rack System-SPEC 2016-07-26
1000 ~ 3000W 1U Distributed Power System
RCP-1U Rack System
3.2 RCP-1000-24
Vout (%)
Vout (%)
100
98
96
94
92
90
110
108
106
104
102
100
R1 (Ω)
min. 0.1W
R2 (Ω)
min. 0.1W
560K
750K
1M
1.6M
3.3M
NC
NC
330K
130K
62K
30K
10K
3.3 RCP-1000-48
Vout (%)
Vout (%)
100
98
96
94
92
90
110
108
106
104
102
100
R1 (Ω)
min. 0.1W
R2 (Ω)
min. 0.1W
1.3M
1.7M
2.4M
3.6M
7.6M
NC
NC
345K
140K
70K
36K
15K
4. I2C Bus Interface Option
※ For the details of I2C option, please refer to the Installation Manual.
File Name:RCP-1U Rack System-SPEC 2016-07-26
1000 ~ 3000W 1U Distributed Power System
RCP-1U Rack System
Mechanical Specification (Rack System)
Case No. 959A
Unit:mm
Fig1
14
1
25
13
ADDRESS
SWITCH
CN500
-
+
14
1
25
LC NC LB NB LA NA
13
Mounting Bracket
RCP-1UT
10
8
ADDRESS
SWITCH
CN500
C
B
A
-
+
14
1
25
13
RCP-1UI
440
1
1
1
1
1
1
22
22
Air flow
direction
Module C
Module B
Module A
10.6
DC OK AC OK
DC OK AC OK
466.2
483.6
DC OK AC OK
Chassis of RCP-1U RACK
Mounting Surface
Mounting Screw
※ Mounting Instruction
Hole No. Recommended Screw Size
MAX. Penetration Depth L
Recommended mounting torque
10Kgf-cm
1
6mm
M5
L
File Name:RCP-1U Rack System-SPEC 2016-07-26
1000 ~ 3000W 1U Distributed Power System
RCP-1U Rack System
※ IN/OUT Connector Pin No. Assignment(CN500) : D-Type Right Angle 25 positions(female type)
14
25
13
1
Pin No.
Function
Description
1,8,15 RemoteON-OFF
Each unit can separately turn the output on and off by electrical or dry contact between Remote ON-OFF A,B,C(pin 1,8,15) and -S(pin 21). Short: ON, Open:OFF.
Low : When input voltage is ≧82Vrms +/-4V.
High : When input voltage in≦82Vrms +/-4V.
2,9,16
AC-OK
High : When Vout≦80%+/-5%.
Low : When Vout ≧80%+/-5%
3,10,17
4,11,18
DC-OK
V-TRIM
Connection for output voltage programming.
High : When the internal temperature is within safe limit.
Low : 10℃ below the thermal shut down limit.
5,12,19 T-ALARM
Auxiliary voltage output, 4.3~5.3V, referenced to GND-AUX(pin 7).
The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by the remote ON/OFF control.
6
+5V-AUX
Auxiliary voltage output GND.
The signal return is isolated from the output terminals (+V & -V).
7
GND-AUX
CS
Current sharing signal.
When units are connected in parallel, the CS pins of the units should be connected to allow current balance between units.
14
20
21
22
23
24
25
+S
-S
Positive sensing for Remote Sense.
Negative sensing for Remote Sense.
+V
Positive output voltage.
Serial clock used in the I2C interface option. Refer to the Instruction Manual.
Serial data used in the I2C interface option. Refer to the Instruction Manual.
Negative output voltage.
SCL
SDA
-V
Installation Manual
Please refer to the manual of RCP-1U system.
File Name:RCP-1U Rack System-SPEC 2016-07-26
相关型号:
©2020 ICPDF网 联系我们和版权申明