VSC8504-01 Datasheet
Quad-Port 10/100/1000BASE-T PHY with Synchronous
Ethernet and QSGMII/SGMII MAC
Microsemi makes no warranty, representation, or guarantee regarding the information contained herein or the suitability of
its products and services for any particular purpose, nor does Microsemi assume any liability whatsoever arising out of the
application or use of any product or circuit. The products sold hereunder and any other products sold by Microsemi have
been subject to limited testing and should not be used in conjunction with mission-critical equipment or applications. Any
performance specifications are believed to be reliable but are not verified, and Buyer must conduct and complete all
performance and other testing of the products, alone and together with, or installed in, any end-products. Buyer shall not
rely on any data and performance specifications or parameters provided by Microsemi. It is the Buyer’s responsibility to
independently determine suitability of any products and to test and verify the same. The information provided by Microsemi
hereunder is provided “as is, where is” and with all faults, and the entire risk associated with such information is entirely
with the Buyer. Microsemi does not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other IP
rights, whether with regard to such information itself or anything described by such information. Information provided in this
document is proprietary to Microsemi, and Microsemi reserves the right to make any changes to the information in this
document or to any products and services at any time without notice.
Microsemi Headquarters
One Enterprise, Aliso Viejo,
CA 92656 USA
Within the USA: +1 (800) 713-4113
Outside the USA: +1 (949) 380-6100
Sales: +1 (949) 380-6136
Fax: +1 (949) 215-4996
Email: sales.support@microsemi.com
www.microsemi.com
About Microsemi
©2018 Microsemi, a wholly owned
subsidiary of Microchip Technology Inc. All
rights reserved. Microsemi and the
Microsemi logo are registered trademarks of
Microsemi Corporation. All other trademarks
and service marks are the property of their
respective owners.
Microsemi, a wholly owned subsidiary of Microchip Technology Inc. (Nasdaq: MCHP), offers a comprehensive portfolio of
semiconductor and system solutions for aerospace & defense, communications, data center and industrial markets.
Products include high-performance and radiation-hardened analog mixed-signal integrated circuits, FPGAs, SoCs and
ASICs; power management products; timing and synchronization devices and precise time solutions, setting the world's
standard for time; voice processing devices; RF solutions; discrete components; enterprise storage and communication
solutions, security technologies and scalable anti-tamper products; Ethernet solutions; Power-over-Ethernet ICs and
midspans; as well as custom design capabilities and services. Learn more at www.microsemi.com.
VMDS-10402. 4.2 11/18
Contents
1 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1
1.2
1.3
1.4
Revision 4.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Revision 4.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Revision 4.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Revision 2.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.1
Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1.1
2.1.2
2.1.3
2.1.4
Low Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Advanced Carrier Ethernet Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Wide Range of Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Flexibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.2
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Functional Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1
Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1.1
3.1.2
3.1.3
3.1.4
3.1.5
3.1.6
3.1.7
3.1.8
QSGMII/SGMII MAC-to-1000BASE-X Link Partner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
QSGMII/SGMII MAC-to-100BASE-FX Link Partner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
QSGMII/SGMII MAC-to-AMS and 1000BASE-X Media SerDes . . . . . . . . . . . . . . . . . . . . . . . . 7
QSGMII/SGMII MAC-to-AMS and 100BASE-FX Media SerDes . . . . . . . . . . . . . . . . . . . . . . . . 8
QSGMII/SGMII MAC-to-AMS and Protocol Transfer Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
QSGMII/SGMII MAC-to-Cat5 Link Partner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
QSGMII/SGMII MAC-to-Protocol Transfer Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1000BASE-X MAC-to-Cat5 Link Partner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.2
3.3
SerDes MAC Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.2.1
3.2.2
3.2.3
SerDes MAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
SGMII MAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
QSGMII MAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
SerDes Media Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.3.1
3.3.2
3.3.3
3.3.4
QSGMII/SGMII to 1000BASE-X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
QSGMII/SGMII to 100BASE-FX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
QSGMII to SGMII Protocol Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Unidirectional Transport for Fiber Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.4
3.5
PHY Addressing and Port Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.4.1
3.4.2
PHY Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
SerDes Port Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Cat5 Twisted Pair Media Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.5.1
3.5.2
3.5.3
3.5.4
3.5.5
3.5.6
3.5.7
Voltage Mode Line Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Cat5 Autonegotiation and Parallel Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Automatic Crossover and Polarity Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Manual HP Auto-MDIX Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Link Speed Downshift . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Energy Efficient Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Ring Resiliency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.6
3.7
Automatic Media Sense Interface Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Reference Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.7.1
3.7.2
3.7.3
Configuring the Reference Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Single-Ended REFCLK Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Differential REFCLK Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.8
3.9
Ethernet Inline Powered Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
IEEE 802.3af PoE Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
iii
3.10
ActiPHY Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.10.1 Low Power State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.10.2 Link Partner Wake-Up State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.10.3 Normal Operating State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.11
3.12
3.13
Media Recovered Clock Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.11.1 Clock Selection Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.11.2 Clock Output Squelch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Serial Management Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.12.1 SMI Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.12.2 SMI Interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
LED Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.13.1 LED Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.13.2 Extended LED Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.13.3 LED Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.13.4 Basic Serial LED Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
3.13.5 Enhanced Serial LED Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
3.13.6 LED Port Swapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.14
3.15
Fast Link Failure Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Integrated Two-Wire Serial Multiplexer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.15.1 Read/Write Access Using the Two-Wire Serial MUX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
3.16
3.17
GPIO Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Testing Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3.17.1 Ethernet Packet Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3.17.2 CRC Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
3.17.3 Far-End Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
3.17.4 Near-End Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
3.17.5 Connector Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.17.6 SerDes Loopbacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.17.7 VeriPHY Cable Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.17.8 JTAG Boundary Scan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
3.17.9 JTAG Instruction Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
3.17.10 Boundary Scan Register Cell Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
3.18
3.19
100BASE-FX Halt Code Transmission and Reception . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
3.19.1 Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
4 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.1
Register and Bit Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.2
IEEE 802.3 and Main Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.2.1
4.2.2
4.2.3
4.2.4
4.2.5
4.2.6
4.2.7
4.2.8
4.2.9
Mode Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Mode Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Device Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Autonegotiation Advertisement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Link Partner Autonegotiation Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Autonegotiation Expansion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Transmit Autonegotiation Next Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Autonegotiation Link Partner Next Page Receive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
1000BASE-T Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
4.2.10 1000BASE-T Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
4.2.11 MMD Access Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
4.2.12 MMD Address or Data Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
4.2.13 1000BASE-T Status Extension 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
4.2.14 100BASE-TX/FX Status Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
4.2.15 1000BASE-T Status Extension 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
4.2.16 Bypass Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
4.2.17 Error Counter 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4.2.18 Error Counter 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
iv
4.2.19 Error Counter 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4.2.20 Extended Control and Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4.2.21 Extended PHY Control Set 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
4.2.22 Extended PHY Control Set 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
4.2.23 Interrupt Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
4.2.24 Interrupt Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
4.2.25 Device Auxiliary Control and Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
4.2.26 LED Mode Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
4.2.27 LED Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
4.2.28 Extended Page Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
4.3
Extended Page 1 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
4.3.1
4.3.2
4.3.3
4.3.4
4.3.5
4.3.6
4.3.7
4.3.8
4.3.9
SerDes Media Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Cu Media CRC Good Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Extended Mode Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
ActiPHY Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
PoE and Miscellaneous Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
VeriPHY Control 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
VeriPHY Control 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
VeriPHY Control 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Ethernet Packet Generator Control 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
4.3.10 Ethernet Packet Generator Control 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
4.4
4.5
Extended Page 2 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
4.4.1
4.4.2
4.4.3
Cu PMD Transmit Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
EEE Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Ring Resiliency Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Extended Page 3 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
4.5.1
4.5.2
4.5.3
4.5.4
4.5.5
4.5.6
4.5.7
4.5.8
4.5.9
MAC SerDes PCS Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
MAC SerDes PCS Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
MAC SerDes Clause 37 Advertised Ability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
MAC SerDes Clause 37 Link Partner Ability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
MAC SerDes Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Media SerDes Transmit Good Packet Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Media SerDes Transmit CRC Error Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Media SerDes PCS Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Media SerDes PCS Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
4.5.10 Media SerDes Clause 37 Advertised Ability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
4.5.11 Media SerDes Clause 37 Link Partner Ability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
4.5.12 Media SerDes Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
4.5.13 Fiber Media CRC Good Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.5.14 Fiber Media CRC Error Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.6
General Purpose Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.6.1
4.6.2
4.6.3
4.6.4
4.6.5
4.6.6
4.6.7
4.6.8
4.6.9
Reserved General Purpose Address Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
SIGDET/GPIO Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
GPIO Control 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
GPIO Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
GPIO Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
GPIO Pin Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Microprocessor Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
MAC Configuration and Fast Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Two-Wire Serial MUX Control 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
4.6.10 Two-Wire Serial MUX Control 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
4.6.11 Two-Wire Serial MUX Data Read/Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
4.6.12 Recovered Clock 1 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
4.6.13 Recovered Clock 2 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
4.6.14 Enhanced LED Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
4.6.15 Global Interrupt Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
4.7
Clause 45 Registers to Support Energy Efficient Ethernet and 802.3bf . . . . . . . . . . . . . . . . . . . . . . . . 88
4.7.1
PCS Status 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
v
4.7.2
4.7.3
4.7.4
4.7.5
EEE Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
EEE Wake Error Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
EEE Advertisement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
EEE Link Partner Advertisement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
5 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
5.1
DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
5.1.1
5.1.2
5.1.3
5.1.4
5.1.5
5.1.6
5.1.7
5.1.8
VDD25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
LED and GPIO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Internal Pull-Up or Pull-Down Resistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Reference Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
SerDes Interface (SGMII) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Enhanced SerDes Interface (QSGMII) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Current Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Thermal Diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
5.2
AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
5.2.1
5.2.2
5.2.3
5.2.4
5.2.5
5.2.6
5.2.7
5.2.8
5.2.9
Reference Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Recovered Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
SerDes Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
SerDes Driver Jitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
SerDes Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
SerDes Receiver Jitter Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Enhanced SerDes Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Basic Serial LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Enhanced Serial LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
5.2.10 JTAG Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
5.2.11 Serial Management Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
5.2.12 Reset Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
5.3
5.4
Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Stress Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
6 Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
6.1
6.2
6.3
Pin Identifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Pin Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Pins by Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
6.3.1
6.3.2
6.3.3
6.3.4
6.3.5
6.3.6
6.3.7
6.3.8
GPIO and SIGDET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
JTAG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
SGMII/SerDes/QSGMII MAC Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
SerDes Media Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Serial Management Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Twisted Pair Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
6.4
6.5
Pins by Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Pins by Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
7 Package Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
7.1
7.2
7.3
Package Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Thermal Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Moisture Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
8 Design Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
8.1
8.2
8.3
AMS and 100BASE-FX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
10BASE-T signal amplitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
SNR degradation and link drops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
vi
8.4
Clause 45 register 3.22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Clause 45 register 3.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Clause 45 register address post-increment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Fast link failure indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Near-end loopback with AMS enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Carrier detect assertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Link status not correct in register 24E3.2 for 100BASE-FX operation . . . . . . . . . . . . . . . . . . . . . . . . . 126
Register 28.14 does not reflect autonegotiation disabled in 100BASE-FX mode . . . . . . . . . . . . . . . . 126
Internal clock disabled when media switches from fiber to copper with autonegotiation disabled . . . . 126
Near-end loopback non-functional in protocol transfer mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Fiber-media recovered clock does not squelch based on link status . . . . . . . . . . . . . . . . . . . . . . . . . . 126
1000BASE-X parallel detect mode with Clause 37 autonegotiation enabled . . . . . . . . . . . . . . . . . . . . 127
Anomalous PCS error indications in Energy Efficient Ethernet mode . . . . . . . . . . . . . . . . . . . . . . . . . 127
8.5
8.6
8.7
8.8
8.9
8.10
8.11
8.12
8.13
8.14
8.15
8.16
9 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
vii
Figures
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Dual Media Application Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Copper Transceiver Application Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Fiber Media Transceiver Application Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SGMII MAC-to-1000BASE-X Link Partner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
QSGMII MAC-to-1000BASE-X Link Partner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
QSGMII/SGMII MAC-to-100BASE-FX Link Partner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
QSGMII/SGMII MAC-to-AMS and 1000BASE-X Media SerDes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
QSGMII/SGMII MAC-to-AMS and 100BASE-FX Media SerDes . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
QSGMII/SGMII MAC-to-AMS and Protocol Transfer Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
QSGMII/SGMII MAC-to-Cat5 Link Partner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
QSGMII/SGMII MAC-to-Protocol Transfer Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1000BASE-X MAC-to-Cat5 Link Partner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SerDes MAC Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
SGMII MAC Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
QSGMII MAC Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cat5 Media Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Low Power Idle Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Automatic Media Sense Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.5 V CMOS Single-Ended REFCLK Input Resistor Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.3 V CMOS Single-Ended REFCLK Input Resistor Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5 V CMOS Single-Ended REFCLK Input Resistor Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
AC Coupling for REFCLK Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Inline Powered Ethernet Switch Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
ActiPHY State Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
SMI Read Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
SMI Write Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
MDINT Configured as an Open-Drain (Active-Low) Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
MDINT Configured as an Open-Source (Active-High) Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Two-Wire Serial MUX with SFP Control and Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Two-Wire Serial MUX Read and Write Register Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Far-End Loopback Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Near-End Loopback Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Connector Loopback Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Data Loops of the SerDes Macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Test Access Port and Boundary Scan Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Register Space Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
SGMII DC Transmit Test Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
SGMII DC Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
SGMII DC Driver Output Impedance Test Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
SGMII DC Input Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Test Circuit for Recovered Clock Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
QSGMII Transient Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Basic Serial LED Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Enhanced Serial LED Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
JTAG Interface Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Test Circuit for TDO Disable Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Serial Management Interface Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Pin Diagram, Top Left . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Pin Diagram, Top Right . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Package Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Figure 9
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14
Figure 15
Figure 16
Figure 17
Figure 18
Figure 19
Figure 20
Figure 21
Figure 22
Figure 23
Figure 24
Figure 25
Figure 26
Figure 27
Figure 28
Figure 29
Figure 30
Figure 31
Figure 32
Figure 33
Figure 34
Figure 35
Figure 36
Figure 37
Figure 38
Figure 39
Figure 40
Figure 41
Figure 42
Figure 43
Figure 44
Figure 45
Figure 46
Figure 47
Figure 48
Figure 49
Figure 50
Figure 51
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
viii
Tables
Table 1
Table 2
Table 3
Table 4
Table 5
Table 6
Table 7
Table 8
Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
MAC Interface Mode Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Supported MDI Pair Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
AMS Media Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
REFCLK Frequency Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
LED Drive State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
LED Mode and Function Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Extended LED Mode and Function Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
LED Serial Bitstream Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Register Bits for GPIO Control and Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
SerDes Macro Address Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
JTAG Instruction Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
IDCODE JTAG Device Identification Register Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
USERCODE JTAG Device Identification Register Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
JTAG Instruction Code IEEE Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
IEEE 802.3 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Main Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Mode Control, Address 0 (0x00) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Mode Status, Address 1 (0x01) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Identifier 1, Address 2 (0x02) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Identifier 2, Address 3 (0x03) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Device Autonegotiation Advertisement, Address 4 (0x04) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Autonegotiation Link Partner Ability, Address 5 (0x05) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Autonegotiation Expansion, Address 6 (0x06) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Autonegotiation Next Page Transmit, Address 7 (0x07) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Autonegotiation LP Next Page Receive, Address 8 (0x08) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
1000BASE-T Control, Address 9 (0x09) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
1000BASE-T Status, Address 10 (0x0A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
MMD EEE Access, Address 13 (0x0D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
MMD Address or Data Register, Address 14 (0x0E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
1000BASE-T Status Extension 1, Address 15 (0x0F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
100BASE-TX/FX Status Extension, Address 16 (0x10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
1000BASE-T Status Extension 2, Address 17 (0x11) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Bypass Control, Address 18 (0x12) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Extended Control and Status, Address 19 (0x13) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Extended Control and Status, Address 20 (0x14) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Extended Control and Status, Address 21 (0x15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Extended Control and Status, Address 22 (0x16) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Extended PHY Control 1, Address 23 (0x17) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Extended PHY Control 2, Address 24 (0x18) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Interrupt Mask, Address 25 (0x19) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Interrupt Status, Address 26 (0x1A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Auxiliary Control and Status, Address 28 (0x1C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
LED Mode Select, Address 29 (0x1D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
LED Behavior, Address 30 (0x1E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Extended/GPIO Register Page Access, Address 31 (0x1F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Extended Registers Page 1 Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
SerDes Media Control, Address 16E1 (0x10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Cu Media CRC Good Counter, Address 18E1 (0x12) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Extended Mode Control, Address 19E1 (0x13) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Extended PHY Control 3, Address 20E1 (0x14) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Extended PHY Control 4, Address 23E1 (0x17) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
VeriPHY Control Register 1, Address 24E1 (0x18) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
VeriPHY Control Register 2, Address 25E1 (0x19) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Table 9
Table 10
Table 11
Table 12
Table 13
Table 14
Table 15
Table 16
Table 17
Table 18
Table 19
Table 20
Table 21
Table 22
Table 23
Table 24
Table 25
Table 26
Table 27
Table 28
Table 29
Table 30
Table 31
Table 32
Table 33
Table 34
Table 35
Table 36
Table 37
Table 38
Table 39
Table 40
Table 41
Table 42
Table 43
Table 44
Table 45
Table 46
Table 47
Table 48
Table 49
Table 50
Table 51
Table 52
Table 53
Table 54
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
ix
Table 55
Table 56
Table 57
Table 58
Table 59
Table 60
Table 61
Table 62
Table 63
Table 64
Table 65
Table 66
Table 67
Table 68
Table 69
Table 70
Table 71
Table 72
Table 73
Table 74
Table 75
Table 76
Table 77
Table 78
Table 79
Table 80
Table 81
Table 82
Table 83
Table 84
Table 85
Table 86
Table 87
Table 88
Table 89
Table 90
Table 91
Table 92
Table 93
Table 94
Table 95
Table 96
Table 97
Table 98
Table 99
Table 100
Table 101
Table 102
Table 103
Table 104
Table 105
Table 106
Table 107
Table 108
Table 109
Table 110
Table 111
Table 112
Table 113
VeriPHY Control Register 3, Address 26E1 (0x1A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
VeriPHY Control Register 3 Fault Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
EPG Control Register 1, Address 29E1 (0x1D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
EPG Control Register 2, Address 30E1 (0x1E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Extended Registers Page 2 Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Cu PMD Transmit Control, Address 16E2 (0x10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
EEE Control, Address 17E2 (0x11) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Ring Resiliency, Address 30E2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Extended Registers Page 3 Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
MAC SerDes PCS Control, Address 16E3 (0x10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
MAC SerDes PCS Status, Address 17E3 (0x11) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
MAC SerDes Cl37 Advertised Ability, Address 18E3 (0x12) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
MAC SerDes Cl37 LP Ability, Address 19E3 (0x13) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
MAC SerDes Status, Address 20E3 (0x14) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Media SerDes Tx Good Packet Counter, Address 21E3 (0x15) . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Media SerDes Tx CRC Error Counter, Address 22E3 (0x16) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Media SerDes PCS Control, Address 23E3 (0x17) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Media SerDes PCS Status, Address 24E3 (0x18) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Media SerDes Cl37 Advertised Ability, Address 25E3 (0x19) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
MAC SerDes Cl37 LP Ability, Address 26E3 (0x1A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Media SerDes Status, Address 27E3 (0x1B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Fiber Media CRC Good Counter, Address 28E3 (0x1C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Fiber Media CRC Error Counter, Address 29E3 (0x1D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
General Purpose Registers Page Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
SIGDET/GPIO Control, Address 13G (0x0D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
GPIO Control 2, Address 14G (0x0E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
GPIO Input, Address 15G (0x0F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
GPIO Output, Address 16G (0x10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
GPIO Input/Output Configuration, Address 17G (0x11) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Microprocessor Command Register, Address 18G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
MAC Configuration and Fast Link Register, Address 19G (0x13) . . . . . . . . . . . . . . . . . . . . . . . . . 83
Two-Wire Serial MUX Control 1, Address 20G (0x14) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Two-Wire Serial MUX Interface Status and Control, Address 21G (0x15) . . . . . . . . . . . . . . . . . . . 84
Two-Wire Serial MUX Data Read/Write, Address 22G (0x16) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Recovered Clock 1 Control, Address 23G (0x17) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Recovered Clock 2 Control, Address 24G (0x18) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Enhanced LED Control, Address 25G (0x19) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Global Interrupt Status, Address 29G (0x1D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Clause 45 Registers Page Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
PCS Status 1, Address 3.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
EEE Capability, Address 3.20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
EEE Wake Error Counter, Address 3.22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
EEE Advertisement, Address 7.60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
EEE Advertisement, Address 7.61 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
802.3bf Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
VDD25 DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
LED and GPIO Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Internal Pull-Up or Pull-Down Resistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Reference Clock DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
SerDes Driver DC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
SerDes Receiver DC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Enhanced SerDes Driver DC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Enhanced SerDes Receiver DC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Current Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Thermal Diode Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Reference Clock AC Characteristics for QSGMII 125 MHz Differential Clock . . . . . . . . . . . . . . . . 97
Recovered Clock AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
SerDes Outputs AC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
SerDes Driver Jitter Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
x
Table 114
Table 115
Table 116
Table 117
Table 118
Table 119
Table 120
Table 121
Table 122
Table 123
Table 124
Table 125
Table 126
Table 127
Table 128
Table 129
Table 130
Table 131
Table 132
Table 133
Table 134
Table 135
Table 136
Table 137
Table 138
Table 139
SerDes Input AC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
SerDes Receiver Jitter Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Enhanced SerDes Outputs AC Specifications, SGMII Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Enhanced SerDes Outputs AC Specifications, QSGMII Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Enhanced SerDes Driver Jitter Characteristics, QSGMII Mode . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Enhanced SerDes Input AC Specifications, SGMII Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Enhanced SerDes Inputs AC Specifications, QSGMII Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Enhanced SerDes Receiver Jitter Tolerance, QSGMII Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Basic Serial LEDs AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Enhanced Serial LEDs AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
JTAG Interface AC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Serial Management Interface AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Reset Timing Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Stress Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Pin Type Symbol Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
GPIO and SIGDET Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
JTAG Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Miscellaneous Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Power Supply Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
SerDes MAC Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
SerDes Media Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
SMI Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Twisted Pair Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Thermal Resistances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
xi
Revision History
1
Revision History
This section describes the changes that were implemented in this document. The changes are listed by
revision, starting with the most current publication.
1.1
1.2
Revision 4.2
Revision 4.2 was published in May 2018. The following is a summary of the changes in this document.
•
•
•
Configuration procedure steps were clarified. For more information, see Configuration, page 42.
The description of bit 10 was updated for register 0. For more information, see Table 18, page 46.
Design considerations were updated. For more information, see Design Considerations, page 125.
Revision 4.1
Revision 4.1 was published in August 2017. The following is a summary of the changes in this document.
•
•
•
All references to LVDS were clarified to reflect LVDS compatibility.
Operating modes were updated to correctly reflect available functionality.
A note was added about the use of recovered clock outputs and fast link failure indication in EEE
mode.
•
•
•
•
•
Data Loops of the SerDes Macro image was updated.
The equipment loop description was updated to correctly reflect available functionality.
JTAG ID code was updated.
Timeout values for ActiPHY link status timeout control registers were corrected.
The default value for the disable carrier extension bit of the ActiPHY Control register was corrected
to 1.
•
•
•
•
•
•
EEE Control register descriptions were updated to indicate sticky bits.
Register 17E3 bit 0 was updated to correctly reflect available functionality.
Clarification footnotes were added for register 18G.
Reference clock DC specifications were updated.
Design considerations were updated.
Temperature specifications were added to the part ordering information.
1.3
1.4
Revision 4.0
Revision 4.0 of this datasheet was published in January 2013. The following is a summary of the
changes implemented in the datasheet:
•
An application diagram was added and existing application diagrams were updated to accurately
reflect the supported interfaces.
•
•
•
•
•
The block diagram was updated to better represent the functional blocks.
Configuration information for operating modes was added.
Several electrical specifications were updated.
Design considerations were added.
An illustration showing the test circuit for the recovered clock output signals was added.
Revision 2.0
Revision 2.0 of this datasheet was published in November 2012. This was the first publication of the
document.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
1
Product Overview
2
Product Overview
The VSC8504-01 is a low-power, quad-port Gigabit Ethernet transceiver with four SerDes interfaces for
quad-port dual media capability. It also includes an integrated quad port two-wire serial multiplexer
(MUX) to control SFPs or PoE modules. It has a low electromagnetic interference (EMI) line driver, and
integrated line side termination resistors that conserve both power and printed circuit board (PCB) space.
The VSC8504-01 includes dual recovered clock outputs to support Synchronous Ethernet applications.
Programmable clock squelch control is included to inhibit undesirable clocks from propagating and to
help prevent timing loops. The VSC8504-01 also supports a ring resiliency feature that allows a
1000BASE-T connected PHY port to switch between master and slave timing without having to interrupt
the 1000BASE-T link.
Using Microsemi’s EcoEthernet v2.0 PHY technology, the VSC8504-01 supports energy efficiency
features such as Energy Efficient Ethernet (EEE), ActiPHY link down power savings, and PerfectReach
that can adjust power based on the cable length. It also supports fully optimized power consumption in all
link speeds.
Microsemi's mixed signal and digital signal processing (DSP) architecture is a key operational feature of
the VSC8504-01, assuring robust performance even under less-than-favorable environmental
conditions. It supports both half-duplex and full-duplex 10BASE-T, 100BASE-TX, and 1000BASE-T
communication speeds over Category 5 (Cat5) unshielded twisted pair (UTP) cable at distances greater
than 100 m, displaying excellent tolerance to NEXT, FEXT, echo, and other types of ambient
environmental and system electronic noise. The device also supports four dual media ports that can
support up to four 100BASE-FX, 1000BASE-X fiber, and/or triple-speed copper SFPs.
The following illustrations show a high-level, general view of typical VSC8504-01 applications.
Figure 1 • Dual Media Application Diagram
1.0 V
2.5 V
1x QSGMII,
4x SGMII, or
4x 1000BASE-X MAC
4× RJ-45
and Magnetics
VSC8504-01
1x QSGMII,
4x SGMII MAC, or
4x 1000BASE-X MAC
4 ports dual media
(fiber or copper)
QSGMII or SGMII
MAC interface
SerDes
4× SFPs
(fiber or copper)
SCL/SDA
Figure 2 • Copper Transceiver Application Diagram
1.0 V
2.5 V
1x QSGMII,
4x SGMII, or
4x 1000BASE-X MAC
VSC8504-01
4 ports copper media
QSGMII or SGMII
MAC interface
1x QSGMII,
4x SGMII MAC, or
4x 1000BASE-X MAC
4× RJ-45
and Magnetics
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
2
Product Overview
Figure 3 • Fiber Media Transceiver Application Diagram
1.0 V
2.5 V
1x QSGMII,
4x SGMII, or
4x 1000BASE-X MAC
VSC8504-01
4 ports fiber media
QSGMII or SGMII
MAC interface
1x QSGMII,
4x SGMII MAC, or
4x 1000BASE-X MAC
4× 1000BASE-X SFP
or
4x 100BASE-FX SFP
2.1
Key Features
This section lists the main features and benefits of the VSC8504-01 device.
2.1.1
Low Power
•
Low power consumption of approximately 425 mW per port in 1000BASE-T mode, 200 mW per port
in 100BASE-TX mode, 225 mW per port in 10BASE-T mode, and less than 115 mW per port in
100BASE-FX and 1000BASE-X modes
•
•
•
ActiPHY™ link down power savings
PerfectReach™ smart cable reach algorithm
IEEE 802.3az-2010 Energy Efficient Ethernet idle power savings
2.1.2
Advanced Carrier Ethernet Support
•
Recovered clock outputs with programmable clock squelch control and fast link failure indication
(<1 ms; worst-case <3 ms) for G.8261 Synchronous Ethernet applications
Ring resiliency for maintaining linkup integrity when switching between 1000BASE-T master and
slave timing
•
•
•
•
Supports IEEE 802.3bf timing and synchronization standard
Integrated quad two-wire serial mux to control SFP and PoE modules
Support for IEEE 802.3ah unidirectional transport for 100BASE-FX and 1000BASE-X fiber media
2.1.3
2.1.4
Wide Range of Support
•
Compliant with IEEE 802.3 (10BASE-T, 100BASE-TX, 1000BASE-T, 100BASE-FX, and
1000BASE-X) specifications
•
•
Support for >16 kB jumbo frames in all speeds with programmable synchronization FIFOs
Supports Cisco QSGMII v1.3, Cisco SGMII v1.9, 1000BASE-X MACs, IEEE 1149.1 JTAG boundary
scan, and IEEE 1149.6 AC-JTAG
•
Available in a low-cost, 256-pin BGA package with a 17 mm × 17 mm body size
Flexibility
•
VeriPHY® cable diagnostics suite provides extensive network cable information such as cable
length, termination status, and open/short fault location
•
•
Patented, low EMI line driver with integrated line side termination resistors
Four programmable direct-drive LEDs per port with adjustable brightness levels using register
controls; bi-color LED support using two LED pins
•
•
Serial LED interface option
Extensive test features including near end, far end, copper media connector, SerDes MAC/media
loopback, and Ethernet packet generator with CRC error counter to decrease time-to-market
Note: All MAC interfaces must be the same — all QSGMII or SGMII.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
3
Product Overview
2.2
Block Diagram
The following illustration shows the primary functional blocks of the VSC8504-01 device.
Figure 4 • Block Diagram
TXVPA_n
TXVNA_n
TXVPB_n
TXVNB_n
TXVPC_n
TXVNC_n
TXVPD_n
TXVND_n
MDI
Twisted
Pair
10/100/
1000BASE-T
PCS and
10/100/
1000BASE-T
PMA
AutoNeg
Interface
RCVRDCLK1
RCVRDCLK2
GPI09/FASTLINK-FAIL
Sync
Ethernet
MAC_TDP_n
MAC_TDN_n
MAC_RDP_n
MAC_RDN_n
100BASE-FX PCS
100BASE-FX PMA
FIBROP_n
FIBRON_n
1000BASE-X Fiber
10/100/1000 SFP
PMA
FIBRIP_n
FIBRIN_n
1000BASE-X Fiber
10/100/1000SFP
PCS and AutoNeg
GPIO[3:0]/SIGDET_n
GPIO8/I2C_SDA
GPIO[7:4]/I2C_SCL_n
I2C MUX
COMA_MODE
REFCLK_P/N
REFCLK_SEL2
REF_FILT_A
REF_REXT_A
SerDes_Rext_[1:0]
Management
NRESET
MDC
MDIO
and
Control Interface
(MIIM)
PLL and Analog
LED Interface
JTAG
MDINT
PHYADD[4:2]
LED[3:0]_[0:3]
Note: All MAC interfaces must be the same—all QSGMII SGMII, or 1000BASE-X.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
4
Functional Descriptions
3
Functional Descriptions
This section describes the functional aspects of the VSC8504-01 device, including available
configurations, operational features, and testing functionality. It also defines the device setup parameters
that configure the device for a particular application.
3.1
Operating Modes
The following table lists the operating modes of the VSC8504-01 device.
Table 1 •
Operating Modes
Operating Mode
Supported Media
Notes
QSGMII/SGMII MAC-to-1000BASE-X 1000BASE-X
Link Partner
See Figure 5, page 6.
QSGMII/SGMII MAC-to-100BASE-FX 100BASE-FX
Link Partner
See Figure 7, page 7.
See Figure 8, page 7.
See Figure 9, page 8.
QSGMII/SGMII MAC-to-AMS and
1000BASE-X SerDes
1000BASE-X,
10/100/1000BASE-T
QSGMII/SGMII MAC-to-AMS and
100BASE-FX SerDes
100BASE-FX,
10/100/1000BASE-T
QSGMII/SGMII MAC-to-AMS and
Protocol Transfer mode
SFP/Fiber Protocol Transfer See Figure 10, page 9.
mode (10/100/1000BASE-T
Cu SFP),
10/100/1000BASE-T
QSGMII/SGMII MAC-to-Cat5 Link
Partner
10/100/1000BASE-T
See Figure 11, page 10.
QSGMII/SGMII MAC-to-Protocol
Transfer mode
SFP/Fiber Protocol Transfer See Figure 12, page 10.
mode (10/100/1000BASE-T
Cu SFP)
1000BASE-X MAC-to-Cat5 Link
Partner
1000BASE-T only
See Figure 13, page 11.
Note: All MAC interfaces must be the same — all QSGMII or SGMII.
3.1.1
QSGMII/SGMII MAC-to-1000BASE-X Link Partner
The following illustrations and sections show the register settings used to configure a QSGMII/SGMII
MAC-to-1000BASE-X link partner.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
5
Functional Descriptions
Figure 5 • SGMII MAC-to-1000BASE-X Link Partner
TXVP_0
TXVN_0
4
4
MDI Twisted Pair,
PMA, PCS, and
AutoNeg
TDP_0
TDN_0
RDP_0
RDN_0
•
•
•
SGMII
MAC
TXVP_3
4
4
TXVN_3
FIBROP/N_0
FIBRIP/N_0
QSGMII/SGMII,
1000BASE-X,
PMA, PCS, and
AutoNeg
Fiber
Fiber
100BASE-FX,
PMA, PCS, and
AutoNeg
•
•
•
•
•
•
1000BASE-X
SFP Module
1000BASE-X
LP
SIGDET0
•
•
•
•
•
•
•
•
•
TDP_3
TDN_3
RDP_3
RDN_3
1000BASE-X Fiber,
10/100/1000BASE-T
Copper SFP, PMA,
PCS, and AutoNeg
FIBROP/N_3
FIBRIP/N_3
Fiber
Fiber
1000BASE-X
SFP Module
1000BASE-X
LP
SIGDET3
3.1.1.1
MAC interface SGMII
Use the following settings to configure the SGMII MAC interface.
•
•
•
Set register 19G bits 15:14 = 00.
Set register 23 (main register) bit 12 = 0.
Set register 18G = 0x80F0. For more information, see Table 63, page 72.
Figure 6 • QSGMII MAC-to-1000BASE-X Link Partner
TXVP_0
TXVN_0
4
4
MDI Twisted Pair,
PMA, PCS, and
AutoNeg
TDP_0
TDN_0
RDP_0
RDN_0
•
•
•
QSGMII
MAC
TXVP_3
4
4
TXVN_3
FIBROP/N_0
FIBRIP/N_0
QSGMII/SGMII,
1000BASE-X,
PMA, PCS, and
AutoNeg
Fiber
100BASE-FX,
PMA, PCS, and
AutoNeg
•
•
•
•
•
•
1000BASE-X
SFP Module
1000BASE-X
LP
Fiber
SIGDET0
•
•
•
•
•
•
•
•
•
TDP_3
TDN_3
RDP_3
RDN_3
1000BASE-X Fiber,
10/100/1000BASE-T
Copper SFP, PMA,
PCS, and AutoNeg
FIBROP/N_3
FIBRIP/N_3
Fiber
Fiber
1000BASE-X
SFP Module
1000BASE-X
LP
SIGDET3
3.1.1.2
3.1.1.3
MAC interface QSGMII
Use the following settings to configure the QSGMII MAC interface.
•
•
•
Set register 19G bits 15:14 = 01.
Set register 23 (main register) bit 12 = 0.
Set register 18G = 0x80F0. For more information, see Table 63, page 72.
Media interface 1000BASE-X SFP Fiber (1000BASE-X Link Partner)
Use the following settings to configure the 1000BASE-X SFP fiber media interface.
•
•
•
Set register 23 bits 10:8 = 010.
Set register 0 bit 12 = 1 (enable autonegotiation).
Set register 18G = 0x8FC1. For more information, see Table 63, page 72.
The F in 0x8FC1 identifies the port. To exclude a port from the configuration, set its bit to 0. For example,
the configuration of port 0 and port 1 to 1000BASE-X is 0011 or 3, making the bit setting 0x83C1.
Note: Whenever there is a mode change a software reset (register 0 bit 15) is required to make the mode
change effective. This register is cleared when read.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
6
Functional Descriptions
3.1.2
QSGMII/SGMII MAC-to-100BASE-FX Link Partner
The following illustration and sections show the register settings used to configure a QSGMII/SGMII
MAC-to-100BASE-FX link partner.
Figure 7 • QSGMII/SGMII MAC-to-100BASE-FX Link Partner
TXVP_0
TXVN_0
4
4
MDI Twisted Pair,
PMA, PCS, and
AutoNeg
TDP_0
TDN_0
RDP_0
RDN_0
•
•
•
QSGMII
MAC
TXVP_3
4
4
TXVN_3
FIBROP/N_0
FIBRIP/N_0
QSGMII/SGMII,
1000BASE-X,
PMA, PCS, and
AutoNeg
Fiber
Fiber
100BASE-FX,
PMA, PCS, and
AutoNeg
•
•
•
•
•
•
100BASE-FX
SFP Module
100BASE-FX
LP
SIGDET0
•
•
•
•
•
•
•
•
•
TDP_3
TDN_3
RDP_3
RDN_3
1000BASE-X Fiber,
10/100/1000BASE-T
Copper SFP, PMA,
PCS, and AutoNeg
FIBROP/N_3
FIBRIP/N_3
Fiber
Fiber
100BASE-FX
SFP Module
100BASE-FX
LP
SIGDET3
3.1.2.1
3.1.2.2
MAC interface SGMII
Use the following settings to configure the SGMII MAC interface.
•
•
•
Set register 19G bits 15:14 = 00.
Set register 23 (main register) bit 12 = 0.
Set register 18G = 0x80F0. For more information, see Table 63, page 72.
Media interface 100BASE-FX SFP Fiber (100BASE-FX Link Partner)
Use the following settings to configure the 100BASE-FX SFP fiber media interface.
•
•
•
Set register 23 bits 10:8 = 011.
Set register 0 bit 12 = 0 (autonegotiation not present in 100BASE-FX PHY).
Set register 18G = 0x8FD1. For more information, see Table 63, page 72.
For QSGMII only port 0 is used.
Note: Whenever there is a mode change a software reset (register 0 bit 15) is required to make the mode
change effective. This register is cleared when read.
3.1.3
QSGMII/SGMII MAC-to-AMS and 1000BASE-X Media SerDes
The following illustration and sections show the register settings used to configure a QSGMII/SGMII
MAC-to-AMS and 1000BASE-X media SerDes.
Figure 8 • QSGMII/SGMII MAC-to-AMS and 1000BASE-X Media SerDes
TXVP_0
TXVN_0
4
4
10/100/1000
BASE-T LP
Port 0
MDI Twisted Pair,
PMA, PCS, and
AutoNeg
TDP_0
TDN_0
RDP_0
RDN_0
•
•
•
•
•
•
•
•
•
QSGMII/
SGMII
MAC
TXVP_3
4
4
10/100/1000
BASE-T LP
Port 3
TXVN_3
FIBROP/N_0
FIBRIP/N_0
QSGMII/SGMII,
1000BASE-X,
PMA, PCS, and
AutoNeg
Fiber
Fiber
100BASE-FX,
PMA, PCS, and
AutoNeg
•
•
•
1000BASE-X
SFP Module
1000BASE-X
LP
SIGDET0
•
•
•
•
•
•
•
•
•
TDP_3
TDN_3
RDP_3
RDN_3
1000BASE-X Fiber,
10/100/1000BASE-T
Copper SFP, PMA,
PCS, and AutoNeg
FIBROP/N_3
FIBRIP/N_3
Fiber
Fiber
1000BASE-X
SFP Module
1000BASE-X
LP
SIGDET3
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
7
Functional Descriptions
3.1.3.1
MAC interface SGMII
Use the following settings to configure the SGMII MAC interface.
•
•
•
Set register 19G bits 15:14 = 00.
Set register 23 (main register) bit 12 = 0.
Set register 18G = 0x80F0. For more information, see Table 63, page 72.
3.1.3.2
3.1.3.3
Media interface 1000BASE-X SFP Fiber (1000BASE-X Link Partner)
Use the following settings to configure the 1000BASE-X SFP fiber media interface.
•
•
Set register 23 bits 10:8 = 010.
Set register 0 bit 12 = 1 (enable autonegotiation).
AMS Preference Setup
Use the following settings for the AMS preferences setup.
•
•
Set register 23 bit 10 = 1 (enable AMS).
Set register 23 bit 11 to the port preferences.
The media selected by AMS can be read from register 20E1 bits 7:6. For more information, see Table 4,
page 18.
For QSGMII only port 0 is used.
Note: Whenever there is a mode change a software reset (register 0 bit 15) is required to make the mode
change effective. This register is cleared when read.
3.1.4
QSGMII/SGMII MAC-to-AMS and 100BASE-FX Media SerDes
The following illustration and sections show the register settings used to configure a QSGMII/SGMII
MAC-to-AMS and 100BASE-FX media SerDes.
Figure 9 • QSGMII/SGMII MAC-to-AMS and 100BASE-FX Media SerDes
TXVP_0
TXVN_0
4
4
10/100/1000
BASE-T LP
Port 0
MDI Twisted Pair,
PMA, PCS, and
AutoNeg
TDP_0
TDN_0
RDP_0
RDN_0
•
•
•
•
•
•
•
•
•
QSGMII/
SGMII
MAC
TXVP_3
4
4
10/100/1000
BASE-T LP
Port 3
TXVN_3
FIBROP/N_0
FIBRIP/N_0
QSGMII/SGMII,
1000BASE-X,
PMA, PCS, and
AutoNeg
Fiber
Fiber
100BASE-FX,
PMA, PCS, and
AutoNeg
•
•
•
100BASE-FX
SFP Module
100BASE-FX
LP
SIGDET0
•
•
•
•
•
•
•
•
•
TDP_3
TDN_3
RDP_3
RDN_3
1000BASE-X Fiber,
10/100/1000BASE-T
Copper SFP, PMA,
PCS, and AutoNeg
FIBROP/N_3
FIBRIP/N_3
Fiber
Fiber
100BASE-FX
SFP Module
100BASE-FX
LP
SIGDET3
3.1.4.1
3.1.4.2
MAC interface SGMII
Use the following settings to configure the SGMII MAC interface.
•
•
•
Set register 19G bits 15:14 = 00.
Set register 23 (main register) bit 12 = 0.
Set register 18G = 0x80F0. For more information, see Table 63, page 72.
Media interface 100BASE-FX SFP Fiber (100BASE-FX Link Partner)
Use the following settings to configure the 100BASE-FX SFP fiber media interface.
•
•
Set register 23 bits 10:8 = 011.
Set register 0 bit 12 = 1 (enable autonegotiation).
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
8
Functional Descriptions
3.1.4.3
AMS Preference Setup
Use the following settings for the AMS preferences setup.
•
•
Set register 23 bit 10 = 1 (enable AMS).
Set register 23 bit 11 to the port preferences.
The media selected by AMS can be read from register 20E1 bits 7;6. For more information, see Table 4,
page 18.
For QSGMII only port 0 is used.
Note: Whenever there is a mode change a software reset (register 0 bit 15) is required to make the mode
change effective. This register is cleared when read.
3.1.5
QSGMII/SGMII MAC-to-AMS and Protocol Transfer Mode
The following illustration and sections show the register settings used to configure a QSGMII/SGMII
MAC-to-AMS and Protocol Transfer mode.
Figure 10 • QSGMII/SGMII MAC-to-AMS and Protocol Transfer Mode
TXVP_0
TXVN_0
4
4
10/100/1000
BASE-T LP
Port 0
MDI Twisted Pair,
PMA, PCS, and
AutoNeg
TDP_0
TDN_0
RDP_0
RDN_0
•
•
•
•
•
•
•
•
•
QSGMII/
SGMII
MAC
TXVP_3
4
4
10/100/1000
BASE-T LP
Port 3
TXVN_3
FIBROP/N_0
FIBRIP/N_0
QSGMII/SGMII,
1000BASE-X,
PMA, PCS, and
AutoNeg
Fiber
Fiber
10/100/1000
BASE-T
Copper SFP
10/100/1000
BASE-T
Copper SFP
100BASE-FX,
PMA, PCS, and
AutoNeg
•
•
•
SIGDET0
•
•
•
•
•
•
•
•
•
TDP_3
TDN_3
RDP_3
RDN_3
1000BASE-X Fiber,
10/100/1000BASE-T
Copper SFP, PMA,
PCS, and AutoNeg
FIBROP/N_3
FIBRIP/N_3
10/100/1000
BASE-T
Copper SFP
10/100/1000
BASE-T
Copper SFP
SIGDET3
3.1.5.1
MAC interface SGMII
Use the following settings to configure the SGMII MAC interface.
•
•
•
Set register 19G bits 15:14 = 00.
Set register 23 (main register) bit 12 = 0.
Set register 18G = 0x80F0. For more information, see Table 63, page 72.
3.1.5.2
3.1.5.3
Media interface 10/100/1000BASE-T Cu-SFP
Use the following settings to configure the fiber/SFP media interface for protocol transfer mode.
•
•
Set register 23 bits 10:8 = 001.
Set register 0 bit 12 = 1 (enable autonegotiation).
AMS Preference Setup
Use the following settings for the AMS preferences setup.
•
•
Set register 23 bit 10 = 1 (enable AMS).
Set register 23 bit 11 to the port preferences.
The media selected by AMS can be read from register 20E1 bits 7;6. For more information, see Table 4,
page 18.
For QSGMII only port 0 is used.
Note: Whenever there is a mode change a software reset (register 0 bit 15) is required to make the mode
change effective. This register is cleared when read.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
9
Functional Descriptions
3.1.6
QSGMII/SGMII MAC-to-Cat5 Link Partner
The following illustration and sections show the register settings used to configure a QSGMII/SGMII
MAC-to-Cat5 link partner.
Figure 11 • QSGMII/SGMII MAC-to-Cat5 Link Partner
TXVP_0
TXVN_0
4
4
10/100/1000
BASE-T LP
Port 0
MDI Twisted Pair,
PMA, PCS, and
AutoNeg
TDP_0
TDN_0
RDP_0
RDN_0
•
•
•
•
•
•
•
•
•
QSGMII/
SGMII
MAC
TXVP_3
4
4
10/100/1000
BASE-T LP
Port 3
TXVN_3
FIBROP/N_0
FIBRIP/N_0
QSGMII/SGMII,
1000BASE-X,
PMA, PCS, and
AutoNeg
100BASE-FX,
PMA, PCS, and
AutoNeg
•
•
•
SIGDET0
•
•
•
TDP_3
TDN_3
RDP_3
RDN_3
1000BASE-X Fiber,
10/100/1000BASE-T
Copper SFP, PMA,
PCS, and AutoNeg
FIBROP/N_3
FIBRIP/N_3
SIGDET3
3.1.6.1
MAC interface SGMII
Use the following settings to configure the SGMII MAC interface.
•
•
•
Set register 19G bits 15:14 = 00.
Set register 23 (main register) bit 12 = 0.
Set register 18G = 0x80F0. For more information, see Table 63, page 72.
For QSGMII only port 0 is used.
Note: Whenever there is a mode change a software reset (register 0 bit 15) is required to make the mode
change effective. This register is cleared when read.
3.1.7
QSGMII/SGMII MAC-to-Protocol Transfer Mode
The following illustration and sections show the register settings used to configure a QSGMII/SGMII
MAC-to-Protocol Transfer mode.
Figure 12 • QSGMII/SGMII MAC-to-Protocol Transfer Mode
TXVP_0
TXVN_0
4
4
MDI Twisted Pair,
PMA, PCS, and
AutoNeg
TDP_0
TDN_0
RDP_0
RDN_0
•
•
•
QSGMII/
SGMII
MAC
TXVP_3
4
4
TXVN_3
FIBROP/N_0
FIBRIP/N_0
QSGMII/SGMII,
1000BASE-X,
PMA, PCS, and
AutoNeg
Fiber
Fiber
10/100/1000
BASE-T
Copper SFP
10/100/1000
BASE-T
Copper SFP
100BASE-FX,
PMA, PCS, and
AutoNeg
•
•
•
SIGDET0
•
•
•
•
•
•
•
•
•
TDP_3
TDN_3
RDP_3
RDN_3
1000BASE-X Fiber,
10/100/1000BASE-T
Copper SFP, PMA,
PCS, and AutoNeg
FIBROP/N_3
FIBRIP/N_3
Fiber
Fiber
10/100/1000
BASE-T
Copper SFP
10/100/1000
BASE-T
Copper SFP
SIGDET3
3.1.7.1
MAC interface SGMII
Use the following settings to configure the SGMII MAC interface.
•
•
•
Set register 19G bits 15:14 = 00.
Set register 23 (main register) bit 12 = 0.
Set register 18G = 0x80F0. For more information, see Table 63, page 72.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
10
Functional Descriptions
3.1.7.2
Media interface 10/100/1000BASE-T Cu-SFP
Use the following settings to configure the fiber/SFP media interface for protocol transfer mode.
•
•
Set register 23 bits 10:8 = 001.
Set register 0 bit 12 = 1 (enable autonegotiation).
For QSGMII only port 0 is used.
Note: Whenever there is a mode change a software reset (register 0 bit 15) is required to make the mode
change effective. This register is cleared when read.
3.1.8
1000BASE-X MAC-to-Cat5 Link Partner
The following illustration and sections show the register settings used to configure a 1000BASE-X MAC-
to-Cat5 Link Partner.
Figure 13 • 1000BASE-X MAC-to-Cat5 Link Partner
TXVP_0
TXVN_0
4
4
Port 0
1000BASE-T LP
MDI Twisted Pair,
PMA, PCS, and
AutoNeg
TDP_0
TDN_0
RDP_0
RDN_0
•
•
•
•
•
•
•
•
•
Fiber
Fiber
1000BASE-X
MAC
1000BASE-T
SFP Module
TXVP_3
4
4
Port 3
TXVN_3
1000BASE-T LP
FIBROP/N_0
FIBRIP/N_0
QSGMII/SGMII,
1000BASE-X,
PMA, PCS, and
AutoNeg
100BASE-FX,
PMA, PCS, and
AutoNeg
•
•
•
•
•
•
•
•
•
SIGDET0
•
•
•
TDP_3
TDN_3
RDP_3
RDN_3
Fiber
Fiber
1000BASE-X Fiber,
10/100/1000BASE-T
Copper SFP, PMA,
PCS, and AutoNeg
FIBROP/N_3
FIBRIP/N_3
1000BASE-X
MAC
1000BASE-T
SFP Module
SIGDET3
In this mode the device provides data throughput of 1000 Mbps only.
3.1.8.1
MAC interface
Use the following settings to configure the MAC interface.
•
•
Set register 19G bits 15:14 = 00.
Set register 23 (main register) bit 12 = 1.
3.1.8.2
Clause 37 MAC Autonegotiation
For clause 37 MAC autonegotiation, set register 16E3 bit 7 = 1.
Note: Whenever there is a mode change a software reset (register 0 bit 15) is required to make the mode
change effective. This register is cleared when read.
3.2
SerDes MAC Interface
The VSC8504-01 SerDes MAC interface performs data serialization and deserialization functions using
an integrated SerDes block. The interface operates in 1000BASE-X compliant mode, QSGMII mode, or
SGMII mode. The SerDes and enhanced SerDes blocks have the termination resistor integrated into the
device. The SerDes block also has the AC decoupling capacitors integrated in the receive path.
Integrated AC decoupling is not supported in the enhanced SerDes block (QSGMII SerDes). Register
19G is a global register and only needs to be set once to configure the device. The other register bits are
configured on a per-port basis and the operation either needs to be repeated for each port, or a
broadcast write needs to be used by setting register 22, bit 0 to configure all the ports simultaneously.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
11
Functional Descriptions
3.2.1
SerDes MAC
When connected to a SerDes MAC compliant to 1000BASE-X, the VSC8504-01 device provides data
throughput at a rate of 1000 Mbps only; 10 Mbps and 100 Mbps rates are not supported. To configure the
device for SerDes MAC mode, set register 19G, bits 15:14 = 0, and register 23, bit 12 = 1. The device
also supports 1000BASE-X Clause 37 MAC-side autonegotiation and is enabled through register 16E3,
bit 7. To configure the rest of the device for 1000 Mbps operation, select 1000BASE-T only by disabling
the 10BASE-T/100BASE-TX advertisements in register 4.
Figure 14 • SerDes MAC Interface
0.1 µF
0.1 µF
0.1 µF
TxP
TxN
RxP
RxN
TxP
100 Ω
TxN
SerDes MAC
PHY Port_n
RxP
100 Ω
0.1 µF
100 Ω
RxN
3.2.2
SGMII MAC
When configured to detect and switch between 10BASE-T, 100BASE-T, and 1000BASE-T data rates, the
VSC8504-01 device can be connected to an SGMII-compatible MAC. To configure the device for SGMII
MAC mode, set register 19G, bits 15:14 = 00 and register 23, bit 12 = 0. In addition, set register 18G as
desired. This device also supports SGMII MAC-side autonegotiation and is enabled through register
16E3, bit 7.
Figure 15 • SGMII MAC Interface
0.1 µF
0.1 µF
0.1 µF
TxP
TxN
RxP
RxN
TxP
100 Ω
TxN
SGMII MAC
PHY Port_n
RxP
100 Ω
0.1 µF
100 Ω
RxN
3.2.3
QSGMII MAC
The VSC8504-01 device supports a QSGMII MAC to convey four ports of network data and port speed
between 10BASE-T, 100BASE-T, and 1000BASE-T data rates and operates in both half-duplex and full-
duplex at all port speeds.The MAC interface protocol for each port within QSGMII can be either
1000BASE-X or SGMII, if the QSGMII MAC that the VSC8504-01 is connecting to supports this
functionality. To configure the device for QSGMII MAC mode, set register 19G, bits 15:14 = 01. In
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
12
Functional Descriptions
addition, set register 18G as desired. The device also supports SGMII MAC-side autonegotiation on each
individual port and is enabled through register 16E3, bit 7, of that port.
Figure 16 • QSGMII MAC Interface
0.1 µF
0.1 µF
0.1 µF
0.1 µF
TxP
TxN
RxP
RxN
TxP
TxN
RxP
RxN
PHY
Port_0
100 Ω
PHY
Port_1
QSGMII MAC
PHY
Port_2
100 Ω
100 Ω
PHY
Port_3
3.3
SerDes Media Interface
The device SerDes media interface performs data serialization and deserialization functions using an
integrated SerDes block in the SerDes media interface. The interface operates at 1.25 Gbps speed,
providing full-duplex and half-duplex for 10/100/1000 Mbps bandwidth that can connect directly to
100BASE-FX/1000BASE-X-compliant optical devices as well as to 10/100/1000BASE-T copper SFP
devices. The interface also provides support for unidirectional transport as defined in IEEE 802.3-2008,
Clause 66. The SerDes interface has the following operating modes:
•
•
•
QSGMII/SGMII to 1000BASE-X
QSGMII/SGMII to 100BASE-FX
QSGMII/SGMII to SGMII/1000BASE-X protocol transfer
The SerDes media block has the termination resistor integrated into the device. It also has the AC
decoupling capacitors integrated in the receive path.
A software reset through register 0, bit 15 is required when changing operating modes between
100BASE-FX and 1000BASE-X.
3.3.1
3.3.2
QSGMII/SGMII to 1000BASE-X
The 1000BASE-X SerDes media in QSGMII/SGMII mode supports IEEE 802.3 Clause 36 and Clause
37, which describe 1000BASE-X fiber autonegotiation. In this mode, control and status of the SerDes
media is displayed in the VSC8504-01 device registers 0 through 15 in a manner similar to what is
described in IEEE 802.3 Clause 28. In this mode, connected copper SFPs can only operate at
1000BASE-T speed. A link in this mode is established using autonegotiation (enabled or disabled)
between the PHY and the link partner. To configure the PHY in this mode, set register 23, bits 10:8 = 010.
To configure 1000BASE-X autonegotiation for this mode, set register 0, bit 12. Setting this mode and
configurations can be performed individually on each of the four ports. Ethernet packet generator (EPG),
cyclical redundancy check (CRC) counters, and loopback modes are supported in 1000BASE-X mode.
QSGMII/SGMII to 100BASE-FX
The VSC8504-01 supports 100BASE-FX communication speed for connecting to fiber modules such as
GBICs and SFPs. This capability is facilitated by using the connections on the SerDes pins when
connected to a MAC through QSGMII/SGMII. Ethernet packet generator (EPG), cyclical redundancy
check (CRC) counters, and loopback modes are supported in the 100BASE-FX mode. Setting this mode
and configurations can be performed individually on each of the four ports. To configure the PHY in this
mode, set register 23, bits 10:8 = 011.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
13
Functional Descriptions
3.3.3
QSGMII to SGMII Protocol Conversion
QSGMII to SGMII (protocol transfer) mode is a feature that links a fiber module or triple speed
10/100/1000-T copper SFP to the QSGMII MAC through the device. SGMII can be converted to QSGMII
with protocol conversion using this mode.
To configure the PHY in this mode, set register 23, bits 10:8 = 001. To establish the link, assert the
relevant signal-detect pin.
All relevant LED modes are supported except for collision, duplex, and autonegotiation fault. The triple-
speed copper SFP’s link status and data type plugged into the port can be indicated by the PHY’s LEDs.
Setting this particular mode and configuration can be performed individually on each of the four ports
within a QSGMII grouping.
3.3.4
Unidirectional Transport for Fiber Media
The VSC8504-01 device supports IEEE 802.3ah for unidirectional transport across its 1000BASE-X and
100BASE-FX fiber media. This feature enables transmission across fiber media, regardless of whether
the PHY has determined that a valid link has been established (register 1, bit 2). The only valid operating
modes for unidirectional fiber mode are 100BASE-FX or 1000BASE-X fiber media.
To enable this feature, set register 0, bit 5 to 1. For status of the unidirectional ability, read register 1,
bit 7.
Note: Automatic media sensing does not work with this feature. In addition, because unidirectional fiber media
must have autonegotiation disabled, SGMII autonegotiation must also be disabled (register 16E3,
bit 7 = 0).
3.4
PHY Addressing and Port Mapping
This section contains information about PHY addressing and port mapping.
3.4.1
3.4.2
PHY Addressing
The VSC8504-01 includes three external PHY address pins, PHYADD[4:2], to allow control of multiple
PHY devices on a system board sharing a common management bus. These pins set the most
significant bits of the PHY address port map. The lower two bits of the address for each port are derived
from the physical address of the port (0 to 3) and the setting of the PHY address reversal bit in register
20E1, bit 9.
SerDes Port Mapping
The VSC8504-01 includes seven 1.25 GHz SerDes macros and one 5 GHz enhanced SerDes macro.
Three of the seven SerDes macros are configured as SGMII MAC interfaces and the remaining four are
configured as 1000BASE-X/100BASE-FX SerDes media interfaces. The enhanced SerDes macro can
be configured as either a QSGMII MAC interface or the fourth SGMII MAC interface. The following table
shows the different operating modes based on the settings of register 19G, bits 15:14.
Table 2 •
MAC Interface Mode Mapping
19G[15:14]
Operating Mode
SGMII
00
01
10
11
QSGMII
Reserved
Reserved
3.5
Cat5 Twisted Pair Media Interface
The VSC8504-01 twisted pair interface is compliant with IEEE 802.3-2008 and the IEEE 802.3az-2010
standard for energy efficient Ethernet.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
14
Functional Descriptions
3.5.1
Voltage Mode Line Driver
Unlike many other gigabit PHYs, the VSC8504-01 uses a patented voltage mode line driver that allows it
to fully integrate the series termination resistors, which are required to connect the PHY’s Cat5 interface
to an external 1:1 transformer. Also, the interface does not require the user to place an external voltage
on the center tap of the magnetic. The following illustration shows the connections.
Figure 17 • Cat5 Media Interface
PHY Port_n
Transformer
TXVPA_n
RJ-45
TXVNA_n
TXVPB_n
TXVNB_n
TXVPC_n
TXVNC_n
TXVPD_n
TXVND_n
3.5.2
Cat5 Autonegotiation and Parallel Detection
The VSC8504-01 supports twisted pair autonegotiation, as defined by IEEE 802.3-2008 Clause 28 and
IEEE 802.3az-2010. The autonegotiation process evaluates the advertised capabilities of the local PHY
and its link partner to determine the best possible operating mode. In particular, autonegotiation can
determine speed, duplex configuration, and master or slave operating modes for 1000BASE-TX.
Autonegotiation also enables a connected MAC to communicate with its link partner MAC through the
VSC8504-01 using optional next pages, which set attributes that may not otherwise be defined by the
IEEE standard.
If the Category 5 (Cat5) link partner does not support autonegotiation, the VSC8504-01 automatically
uses parallel detection to select the appropriate link speed.
Autonegotiation is disabled by clearing register 0, bit 12. When autonegotiation is disabled, the state of
register bits 0.6, 0.13, and 0.8 determine the device operating speed and duplex mode.
Note: While 10BASE-T and 100BASE-TX do not require autonegotiation, Clause 40 has defined 1000BASE-T
to require autonegotiation.
3.5.3
Automatic Crossover and Polarity Detection
For trouble-free configuration and management of Ethernet links, the VSC8504-01 includes a robust
automatic crossover detection feature for all three speeds on the twisted pair interface (10BASE-T,
100BASE-T, and 1000BASE T). Known as HP Auto-MDIX, the function is fully compliant with Clause 40
of IEEE 802.3-2008.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
15
Functional Descriptions
Additionally, the device detects and corrects polarity errors on all MDI pairs — a useful capability that
exceeds the requirements of the standard.
Both HP Auto-MDIX detection and polarity correction are enabled in the device by default. Default
settings can be changed using device register bits 18.5:4. Status bits for each of these functions are
located in register 28.
Note: The VSC8504-01 can be configured to perform HP Auto-MDIX, even when autonegotiation is disabled
and the link is forced into 10/100 speeds. To enable this feature, set register 18.7 to 0. To use the
feature, also set register 0.12 to 0.
The HP Auto-MDIX algorithm successfully detects, corrects, and operates with any of the MDI wiring pair
combinations listed in the following table, which shows that twisted pair A (of four twisted paris A, B, C,
and D) is connected to the RJ45 connector 1,2 in normal MDI mode.
Table 3 •
Supported MDI Pair Combinations
RJ45 Connections
1, 2 3, 6 4, 5 7, 8 Mode
A
B
A
B
B
A
B
A
C
D
D
C
D
C
C
D
Normal MDI
Normal MDI-X
Normal MDI with pair swap on C and D pair
Normal MDI-X with pair swap on C and D pair
3.5.4
3.5.5
Manual HP Auto-MDIX Setting
As an alternative to HP Auto-MDIX detection, the PHY can be forced to be MDI or MDI-X using register
19E1, bits 3:2. Setting these bits to 10 forces MDI and setting 11 forces MDI-X. Leaving the bits 00
enables the HP Auto-MDIX setting to be based on register 18, bits 7 and 5.
Link Speed Downshift
For operation in cabling environments that are incompatible with 1000BASE-T, the VSC8504-01 provides
an automatic link speed downshift option. When enabled, the device automatically changes its
1000BASE-T autonegotiation advertisement to the next slower speed after a set number of failed
attempts at 1000BASE-T. No reset is required to get out of this state when a subsequent link partner with
1000BASE-T support is connected. This feature is useful in setting up in networks using older cable
installations that include only pairs A and B, and not pairs C and D.
To configure and monitor link speed downshifting, set register 20E1, bits 4:1. For more information, see
Table 29, page 52.
3.5.6
Energy Efficient Ethernet
The VSC8504-01 supports the IEEE 802.3az-2010 Energy Efficient Ethernet standard. This standard
provides a method for reducing power consumption on an Ethernet link during times of low utilization. It
uses low power idles (LPI) to achieve this objective.
Figure 18 • Low Power Idle Operation
Active
Low Power Idle
Quiet
Active
Quiet
Tq
Quiet
Ts
Tr
Using LPI, the usage model for the link is to transmit data as fast as possible and then return to a low
power idle state. Energy is saved on the link by cycling between active and low power idle states. During
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
16
Functional Descriptions
LPI, power is reduced by turning off unused circuits and using this method, energy use scales with
bandwidth utilization.
The VSC8504-01 uses LPI to optimize power dissipation in 100BASE-TX and 1000BASE-T modes of
operation. In addition, the IEEE 802.3az-2010 standard defines a 10BASE-Te mode that reduces
transmit signal amplitude from 5 V peak-to-peak to approximately 3.3 V peak-to-peak. This mode
reduces power consumption in 10 Mbps link speed and fully interoperates with legacy 10BASE-T
compliant PHYs over 100 m Cat5 cable or better.
To configure the VSC8504-01 in 10BASE-Te mode, set register 17E2.15 to 1 for each port. Additional
energy efficient Ethernet features are controlled through Clause 45 registers. For more information, see
Design Considerations, page 125.
3.5.7
Ring Resiliency
Ring resiliency changes the timing reference between the master and slave PHYs without altering the
master/slave configuration in 1000BASE-T mode. The master PHY transmitter sends data based on the
local clock and initiates timing recovery in the receiver. The slave PHY instructs node to switch the local
timing reference to the recovered clock from other PHYs in the box, freezes timing recovery, and locks
clock frequency for the transmitter. The master PHY makes a smooth transition to transmission from
local clock to recovered clock after timing lock is achieved.
Ring resiliency can be used in synchronous Ethernet systems, because the local clocks in each node are
synchronized to a grandmaster clock.
Note: For ring resiliency to successfully exchange master/slave timing over 1000BASE-T, the link partner must
also support ring resiliency.
3.6
Automatic Media Sense Interface Mode
Automatic media sense (AMS) mode automatically sets the media interface to Cat5 mode or SerDes
mode. The active media mode chosen is based on the automatic media sense preferences set in the
device register 23, bit 11. The following illustration shows a block diagram of AMS functionality on ports 0
through 3 of the VSC8504-01 device.
Figure 19 • Automatic Media Sense Block Diagram
PHY port_n
Cat5
MAC
QSGMII/
SGMII
Serial MAC
Auto Sense
Logic
TD
RD
SerDes
SIGDET
Fiber Optic
Module
When both the SerDes and Cat5 media interfaces attempt to establish a link, the preferred media
interface overrides a linkup of the nonpreferred media interface. For example, if the preference is set for
SerDes mode and Cat5 media establishes a link, Cat5 becomes the active media interface. However,
after the SerDes media interface establishes a link, the Cat5 interface drops its link because the
preference was set for SerDes mode. In this scenario, the SerDes preference determines the active
media source until the SerDes link is lost. Also, Cat5 media cannot link up unless there is no SerDes
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
17
Functional Descriptions
media link established. The following table shows the possible link conditions based on preference
settings.
Table 4 •
AMS Media Preferences
Cat5 Linked,
SerDes Linked, Both Cat5 and
Preference Cat5 Linked,
SerDes Linked,
SerDes Attempts Cat5 Attempts
SerDes Attempt
to Link
Setting
SerDes
Cat5
Fiber Not Linked Cat5 Not Linked to Link
to Link
SerDes
Cat5
Cat5
Cat5
SerDes
SerDes
SerDes
Cat5
SerDes
Cat5
The status of the media mode selected by the AMS can be read from device register 20E1, bits 7:6. It
indicates whether copper media, SerDes media, or no media is selected. Each PHY has four automatic
media sense modes. The difference between the modes is based on the SerDes media modes:
•
•
•
SGMII or QSGMII MAC to AMS and 1000BASE-X SerDes
SGMII or QSGMII MAC to AMS and 100BASE-FX SerDes
SGMII or QSGMII MAC to AMS and SGMII (protocol transfer)
For more information about SerDes media mode functionality with AMS enabled, see SerDes Media
Interface, page 13.
3.7
Reference Clock
The device reference clock supports both 25 MHz and 125 MHz clock signals. The reference clock can
be either differential or single-ended. If differential, it must be capacitively coupled and LVDS compatible.
3.7.1
Configuring the Reference Clock
The REFCLK_SEL2 pin configures the reference clock speed. The following table shows the functionality
and associated reference clock frequency.
Table 5 •
REFCLK Frequency Selection
REFCLK_SEL2 Frequency
0
1
25 MHz
125 MHz
3.7.2
Single-Ended REFCLK Input
To use a single-ended reference clock, an external resistor network is required. The purpose of the
network is to limit the amplitude and to adjust the center of the swing. The configurations for a single-
ended REFCLK, with the clock centered at 1 V and a 500 mV peak-to-peak swing, are shown in the
following illustrations.
Figure 20 • 2.5 V CMOS Single-Ended REFCLK Input Resistor Network
VDD1A
220 Ω
REFCLK_P
2.5 V
CMOS
REFCLK_N
910 Ω
VDD1A
VSSA
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
18
Functional Descriptions
Figure 21 • 3.3 V CMOS Single-Ended REFCLK Input Resistor Network
VDD1A
270 Ω
REFCLK_P
3.3 V
CMOS
REFCLK_N
430 Ω
VDD1A
VSSA
Figure 22 • 5 V CMOS Single-Ended REFCLK Input Resistor Network
VDD1A
430 Ω
300 Ω
REFCLK_P
5 V
CMOS
REFCLK_N
VDD1A
VSSA
Note: A single-ended 25 MHz reference clock is not guaranteed to meet requirements for QSGMII MAC
operation.
3.7.3
Differential REFCLK Input
AC coupling is required when using a differential REFCLK. Differential clocks must be capacitively
coupled and LVDS compatible. The following illustration shows the configuration.
Figure 23 • AC Coupling for REFCLK Input
REFCLK_P
PHY Equivalent
Termination Circuit
0.1 µF
50 Ω
50 Ω
VTT (Internal Voltage)
REFCLK_N
0.1 µF
3.8
Ethernet Inline Powered Devices
The VSC8504-01 can detect legacy inline powered devices in Ethernet network applications. Inline
powered detection capability is useful in systems that enable IP phones and other devices (such as
wireless access points) to receive power directly from their Ethernet cable, similar to office digital phones
receiving power from a private branch exchange (PBX) office switch over telephone cabling. This type of
setup eliminates the need for an external power supply and enables the inline powered device to remain
active during a power outage, assuming that the Ethernet switch is connected to an uninterrupted power
supply, battery, back-up power generator, or other uninterruptable power source.
For more information about legacy inline powered device detection, visit the Cisco Web site at
www.cisco.com. The following illustration shows an example of an inline powered Ethernet switch
application.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
19
Functional Descriptions
Figure 24 • Inline Powered Ethernet Switch Diagram
Gigabit Switch
Processor
Control
QSGMII/
SGMII
SMI
Interface
Inline,
Power-Over-Ethernet
(PoE)
PHY_port0
PHY_port1
PHY_portn
Power Supply
Transformer
Transformer
Transformer
RJ-45
I/F
RJ-45
I/F
RJ-45
I/F
Cat5
Link
Partner
Link
Partner
Link
Partner
The following procedure describes the process that an Ethernet switch must perform to process inline
power requests made by a link partner (LP) that is, in turn, capable of receiving inline power:
1. Enable the inline powered device detection mode on each VSC8504-01 PHY using its serial
management interface. Set register bit 23E1.10 to 1.
2. Ensure that the VSC8504-01 autonegotiation enable bit (register 0.12) is also set to 1. In the
application, the device sends a special fast link pulse (FLP) signal to the LP. Reading register
bit 23E1.9:8 returns 00 during the search for devices that require power over Ethernet (PoE).
3. The VSC8504-01 PHY monitors its inputs for the FLP signal looped back by the LP. An LP capable
of receiving PoE loops back the FLP pulses when the LP is in a powered down state. This is
reported when VSC8504-01 register bit 23E1.9:8 reads back 01. It can also be verified as an inline
power detection interrupt by reading VSC8504-01 register bit 26.9, which should be a 1, and which
is subsequently cleared and the interrupt de-asserted after the read. When an LP device does not
loop back the FLP after a specific time, VSC8504-01 register bit 23E1.9:8 automatically resets to 10.
4. If the VSC8504-01 PHY reports that the LP requires PoE, the Ethernet switch must enable inline
power on this port, externally of the PHY.
5. The PHY automatically disables inline powered device detection when the VSC8504-01 register bits
23E1.9:8 automatically reset to 10, and then automatically changes to its normal autonegotiation
process. A link is then autonegotiated and established when the link status bit is set (register bit 1.2
is set to 1).
6. In the event of a link failure (indicated when VSC8504-01 register bit 1.2 reads 0), it is
recommended that the inline power be disabled to the inline powered device external to the PHY.
The VSC8504-01 PHY disables its normal autonegotiation process and re-enables its inline
powered device detection mode.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
20
Functional Descriptions
3.9
IEEE 802.3af PoE Support
The VSC8504-01 device is compatible with designs that are intended for use in systems that supply
power to data terminal equipment (DTE) by means of the MDI or twisted pair cable, as described in IEEE
802.3af Clause 33.
3.10 ActiPHY Power Management
In addition to the IEEE-specified power-down control bit (device register bit 0.11), the device also
includes an ActiPHY power management mode for each PHY. This mode enables support for power-
sensitive applications. It utilizes a signal-detect function that monitors the media interface for the
presence of a link to determine when to automatically power-down the PHY. The PHY wakes up at a
programmable interval and attempts to wake up the link partner PHY by sending a burst of FLP over
copper media.
The ActiPHY power management mode in the VSC8504-01 is enabled on a per-port basis during normal
operation at any time by setting register bit 28.6 to 1.
The following operating states are possible when ActiPHY mode is enabled:
•
•
•
Low power state
Link partner wake-up state
Normal operating state (link-up state)
The VSC8504-01 switches between the low power state and LP wake-up state at a programmable rate
(the default is two seconds) until signal energy has been detected on the media interface pins. When
signal energy is detected, the PHY enters the normal operating state. If the PHY is in its normal operating
state and the link fails, the PHY returns to the low power state after the expiration of the link status time-
out timer. After reset, the PHY enters the low power state.
When autonegotiation is enabled in the PHY, the ActiPHY state machine operates as described. When
autonegotiation is disabled and the link is forced to use 10BASE-T or 100BASE-TX modes while the
PHY is in its low power state, the PHY continues to transition between the low power and LP wake-up
states until signal energy is detected on the media pins. At that time, the PHY transitions to the normal
operating state and stays in that state even when the link is dropped. When autonegotiation is disabled
while the PHY is in the normal operation state, the PHY stays in that state when the link is dropped and
does not transition back to the low power state.
The following illustration shows the relationship between ActiPHY states and timers.
Figure 25 • ActiPHY State Diagram
Low Power State
Signal Energy Detected on
Media
FLP Burst or
Clause 37 Restart
Signal Sent
Sleep Timer Expires
Timeout Timer Expires and
Auto-negotiation Enabled
Normal
Operation State
LP Wake-up
State
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
21
Functional Descriptions
3.10.1 Low Power State
In the low power state, all major digital blocks are powered down. However, the SMI interface (MDC,
MDIO, and MDINT) functionality is provided.
In this state, the PHY monitors the media interface pins for signal energy. The PHY comes out of low
power state and transitions to the normal operating state when signal energy is detected on the media.
This happens when the PHY is connected to one of the following:
•
•
Autonegotiation-capable link partner
Another PHY in enhanced ActiPHY LP wake-up state
In the absence of signal energy on the media pins, the PHY periodically transitions from low-power state
to LP wake-up state, based on the programmable sleep timer (register bits 20E1.14:13). The actual sleep
time duration is randomized from –80 ms to 60 ms to avoid two linked PHYs in ActiPHY mode entering a
lock-up state during operation.
3.10.2 Link Partner Wake-Up State
In the link partner wake-up state, the PHY attempts to wake up the link partner. Up to three complete FLP
bursts are sent on alternating pairs A and B of the Cat5 media for a duration based on the wake-up timer,
which is set using register bits 20E1.12:11.
In this state, SMI interface (MDC, MDIO, and MDINT) functionality is provided.
After sending signal energy on the relevant media, the PHY returns to the low power state.
3.10.3 Normal Operating State
In the normal operating state, the PHY establishes a link with a link partner. When the media is
unplugged or the link partner is powered down, the PHY waits for the duration of the programmable link
status time-out timer, which is set using register bit 28.7 and bit 28.2. It then enters the low power state.
3.11 Media Recovered Clock Outputs
For Synchronous Ethernet applications, the VSC8504-01 includes two recovered clock output pins,
RCVRDCLK1 and RCVRDCLK2, controlled by registers 23G and 24G, respectively. The recovered clock
pins are synchronized to the clock of the active media link.
To enable recovered clock output, set register 23G or 24G, bit 15, to 1. By default, the recovered clock
output pins are disabled and held low, including when NRESET is asserted. Registers 23G and 24G also
control the PHY port for clock output, the clock source, the clock frequency (either 25 MHz, 31.25 MHz,
or 125 MHz), and squelch conditions.
Note: When EEE is enabled on a link, the use of the recovered clock output is not recommended due to long
holdovers occurring during EEE Quiet/Refresh cycles.
3.11.1 Clock Selection Settings
On each pin, the recovered clock supports the following sources, as set by registers 23G or 24G, bits 2:0:
•
•
•
Fiber SerDes media recovered clock
Copper PHY recovered clock
Copper PHY media transmitter TCLK output (RCVRDCLK1 only.) For more information, see
Table 68, page 75 and Table 69, page 75.
Note: When using the automatic media sense feature, the recovered clock output cannot automatically change
between each active media. Changing the media source must be managed through the recovered clock
register settings.
Adjust the squelch level to enable 1000BASE-T master mode recovered clock for SyncE operation. This
is accomplished by changing the 23G and 24G register bits 5:4 to 01. This setting also provides clock out
for 10BASE-T operation. For 1000BASE-T master mode, the clock is based on the VSC8504-01
REFCLK input, which is a local clock.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
22
Functional Descriptions
3.11.2 Clock Output Squelch
Under certain conditions, the PHY outputs a clock based on the REFCLK_P and REFCLK_N pins, such
as when there is no link present or during autonegotiation. To prevent an undesirable clock from
appearing on the recovered clock pins, the VSC8504-01 squelches, or inhibits, the clock output based on
any of the following criteria:
•
•
•
•
No link is detected (the link status register 1, bit 2 = 0). In fiber media modes, sync status is required
to unsquelch the recovered clock output instead of link status.
The link is found to be unstable using the fast link failure detection feature. The
GPIO9/FASTLINK-FAIL pin is asserted high when enabled.
The active link is in 10BASE-T or in 1000BASE-T master mode. These modes produce unreliable
recovered clock sources.
CLK_SQUELCH_IN is enabled to squelch the clock.
Use registers 23G or 24G, bits 5:4 to configure the clock squelch criteria. These registers can also
disable the squelch feature. The CLK_SQUELCH_IN pin controls the squelching of the clock. Both
RCVRDCLK1 and RCVRDCLK2 are squelched when the CLK_SQUELCH_IN pin is high.
3.12 Serial Management Interface
The VSC8504-01 device includes an IEEE 802.3-compliant serial management interface (SMI) that is
affected by use of its MDC and MDIO pins. The SMI provides access to device control and status
registers. The register set that controls the SMI consists of 32 16-bit registers, including all required
IEEE-specified registers. Also, there are additional pages of registers accessible using device register
31.
Energy efficient Ethernet control registers are available through the SMI using Clause 45 registers and
Clause 22 register access in registers 13 through 14. For more information, see Table 7, page 25 and
Table 72, page 76.
The SMI is a synchronous serial interface with input data to the VSC8504-01 on the MDIO pin that is
clocked on the rising edge of the MDC pin. The output data is sent on the MDIO pin on the rising edge of
the MDC signal. The interface can be clocked at a rate from 0 MHz to 12.5 MHz, depending on the total
load on MDIO. An external 2-kΩ pull-up resistor is required on the MDIO pin.
3.12.1 SMI Frames
Data is transferred over the SMI using 32-bit frames with an optional, arbitrary-length preamble. Before
the first frame can be sent, at least two clock pulses on MDC must be provided with the MDIO signal at
logic one to initialize the SMI state machine. The following illustrations show the SMI frame format for
read and write operations.
Figure 26 • SMI Read Frame
Station manager drives MDIO
PHY drives MDIO
MDC
MDIO
Z
Z
1
0
1
1
0
A4 A3 A2 A1 A0 R4 R3 R2 R1 R0
Z
0
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
Z
Z
Preamble
(optional)
Register Data
from PHY
Register Address
to PHY
Idle
SFD Read
PHY Address
TA
Idle
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
23
Functional Descriptions
Figure 27 • SMI Write Frame
Station manager drives MDIO (PHY tri-states MDIO during the entire sequence)
MDC
MDIO
Z
Z
1
0
1
0
1
A4 A3 A2 A1 A0 R4 R3 R2 R1 R0
1
0
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
Z
Z
Preamble
(optional)
Register Data
to PHY
Register Address
to PHY
Idle
SFD Write
PHY Address
TA
Idle
The following list provides additional information about the terms used in the SMI read and write timing
diagrams.
•
Idle During idle, the MDIO node goes to a high-impedance state. This allows an external pull-up
resistor to pull the MDIO node up to a logical 1 state. Because the idle mode does not contain any
transitions on MDIO, the number of bits is undefined during idle.
•
•
•
•
Preamble By default, preambles are not expected or required. The preamble is a string of ones. If
it exists, the preamble must be at least 1 bit; otherwise, it can be of an arbitrary length.
Start of Frame (SFD) A pattern of 01 indicates the start of frame. If the pattern is not 01, all
following bits are ignored until the next preamble pattern is detected.
Read or Write Opcode A pattern of 10 indicates a read. A 01 pattern indicates a write. If the bits
are not either 01 or 10, all following bits are ignored until the next preamble pattern is detected.
PHY Address The particular VSC8504-01 responds to a message frame only when the received
PHY address matches its physical address. The physical address is 5 bits long (4:0).
Register Address The next five bits are the register address.
•
•
Turnaround The two bits used to avoid signal contention when a read operation is performed on
the MDIO are called the turnaround (TA) bits. During read operations, the VSC8504-01 drives the
second TA bit, a logical 0.
•
Data The 16-bits read from or written to the device are considered the data or data stream. When
data is read from a PHY, it is valid at the output from one rising edge of MDC to the next rising edge
of MDC. When data is written to the PHY, it must be valid around the rising edge of MDC.
Idle The sequence is repeated.
•
3.12.2 SMI Interrupt
The SMI includes an output interrupt signal, MDINT, for signaling the station manager when certain
events occur in the VSC8504-01.
The MDINT pin can be configured for open-drain (active-low) by tying the pin to a pull-up resistor and to
VDDIO. The following illustration shows this configuration.
Figure 28 • MDINT Configured as an Open-Drain (Active-Low) Pin
External Pull-up
Resistor at the
VDDIO
Station Manager
for Open-drain
(Active-low Mode)
PHY_n
Interrupt Pin Enable
(Register 25.15)
MDINT
(to the Station
Manager)
MDINT
Interrupt Pin Status
(Register 26.15)
Alternatively, the MDINT pin can be configured for open-source (active-high) by tying the pin to a pull-
down resistor and to VSS. The following illustration shows this configuration.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
24
Functional Descriptions
Figure 29 • MDINT Configured as an Open-Source (Active-High) Pin
VDDIO
Interrupt Pin Enable
(Register 25.15)
MDINT
(to the Station
Manager)
External Pull-down
at the Station
MDINT
Interrupt Pin Status
(Register 26.15)
PHY_n
Manager
For Open-source
(Active-high Mode)
When a PHY generates an interrupt, the MDINT pin is asserted (driven high or low, depending on resistor
connection) if the interrupt pin enable bit (MII register 25.15) is set.
3.13 LED Interface
The LED interface supports the following configurations: direct drive, basic serial LED mode, and
enhanced serial LED mode. The polarity of the LED outputs is programmable and can be changed
through register 17E2, bits 13:10. The default polarity is active low.
Direct drive mode provides four LED signals per port, LED0_[0:3] through LED3_[0:3]. The mode and
function of each LED signal can be configured independently. When serial LED mode is enabled, the
direct drive pins not used by the serial LED interface remain available.
In basic serial LED mode, all signals that can be displayed on LEDs are sent as LED_Data and
LED_CLK for external processing. In enhanced serial LED mode, up to four LED signals per port can be
sent as LED_Data, LED_CLK, LED_LD, and LED_Pulse. The following sections provide detailed
information about the various LED modes.
Note: LED number is listed using the convention, LED<LED#>_<Port#>.
The following table shows the bit 9 settings for register 14G that are used to control the LED behavior for
all the LEDs in VSC8504-01.
Table 6 •
LED Drive State
Setting
Active
Ground
Ground
Not Active
Tristate
VDD
14G.9 = 1 (default)
14G.9 = 0 (alternate setting)
3.13.1 LED Modes
Each LED pin can be configured to display different status information that can be selected by setting the
LED mode in register 29. The modes listed in the following table are equivalent to the setting used in
register 29 to configure each LED pin. The default LED state is active low and can be changed by
modifying the value in register 17E2, bits 13:10. The blink/pulse-stretch is dependent on the LED
behavior setting in register 30.
The following table provides a summary of the LED modes and functions.
Table 7 •
LED Mode and Function Summary
Mode Function Name
Link/Activity
LED State and Description
0
1: No link in any speed on any media interface.
0: Valid link at any speed on any media interface.
Blink or pulse-stretch = Valid link at any speed on any media
interface with activity present.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
25
Functional Descriptions
Table 7 •
LED Mode and Function Summary (continued)
Mode Function Name
LED State and Description
1
2
3
4
Link1000/Activity
1: No link in 1000BASE-T or 1000BASE-X.
0: Valid 1000BASE-T or 1000BASE-X.
Blink or pulse-stretch = Valid 1000BASE-T or 1000BASE-X
link with activity present.
Link100/Activity
Link10/Activity
1: No link in 100BASE-TX or 100BASE-FX.
0: Valid 100BASE-TX or 100BASE-FX.
Blink or pulse-stretch = Valid 100BASE-TX or 100BASE-FX
link with activity present.
1: No link in 10BASE-T.
0: Valid 10BASE-T link.
Blink or pulse-stretch = Valid 10BASE-T link with activity
present.
Link100/1000/Activity
1: No link in 100BASE-TX, 100BASE-FX, 1000BASE-X, or
1000BASE-T.
0: Valid 100BASE-TX, 100BASE-FX, 1000BASE-X, or
1000BASE-T link. Blink or pulse-stretch = Valid 100BASE-TX,
100BASE-FX, 1000BASE-X, or 1000BASE-T link with activity
present.
5
6
7
8
Link10/1000/Activity
Link10/100/Activity
1: No link in 10BASE-T, 1000BASE-X, or 1000BASE-T.
0: Valid 10BASE-T, 1000BASE-X, or 1000BASE-T link.
Blink or pulse-stretch = Valid 10BASE-T, 1000BASE-X, or
1000BASE-T link with activity present.
1: No link in 10BASE-T, 100BASE-FX, or 100BASE-TX.
0: Valid 10BASE-T, 100BASE-FX, or 100BASE-TX link.
Blink or pulse-stretch = Valid 10BASE-T, 100BASE-FX, or
100BASE-TX link with activity present.
Link100BASE-FX/1000BAS 1: No link in 100BASE-FX or 1000BASE-X.
E-X/Activity
0: Valid 100BASE-FX or 1000BASE-X link.
Blink or pulse-stretch = Valid 100BASE-FX or 1000BASE-X
link with activity present.
Duplex/Collision
1: Link established in half-duplex mode, or no link established.
0: Link established in full-duplex mode.
Blink or pulse-stretch = Link established in half-duplex mode
but collisions are present.
9
Collision
Activity
1: No collision detected.
Blink or pulse-stretch = Collision detected.
10
1: No activity present.
Blink or pulse-stretch = Activity present (becomes TX activity
present when register bit 30.14 is set to 1).
11
100BASE-FX/1000BASE-X 1: No 100BASE-FX or 1000BASE-X activity present.
Fiber Activity
Blink or pulse-stretch = 100BASE-FX or 1000BASE-X activity
present (becomes RX activity present when register bit 30.14
is set to 1).
12
13
Autonegotiation Fault
Serial Mode
1: No autonegotiation fault present.
0: Autonegotiation fault occurred.
Serial stream. See Basic Serial LED Mode, page 28. Only
relevant on PHY port 0 and reserved in others.
14
15
Force LED Off
Force LED On
1: De-asserts the LED(1)
0: Asserts the LED(1)
.
.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
26
Functional Descriptions
1. Setting this mode suppresses LED blinking after reset.
3.13.2 Extended LED Modes
In addition to the LED modes in register 29, there are also additional LED modes that are enabled on the
LED0_[3:0] pins whenever the corresponding register 19E1, bits 15 to 12 are set to 1. Each of these bits
enables extended modes on a specific LED pin and these extended modes are shown in the following
table. For example, LED0 = mode 17 means that register 19E1 bit 12 = 1 and register 29 bits 3 to
0 = 0001.
The following table provides a summary of the extended LED modes and functions.
Table 8 •
Extended LED Mode and Function Summary
Mode Function Name
LED State and Description
16
17
18
19
Link1000BASE-X Activity 1: No link in 1000BASE-X.
0: Valid 1000BASE-X link.
Link100BASE-FX Activity 1: No link in 100BASE-FX.
0: Valid 100BASE-FX link.
1000BASE-X Activity
1: No 1000BASE-X activity present.
Blink or pulse-stretch = 1000BASE-X activity present.
100BASE-FX Activity
1: No 100BASE-FX activity present.
Blink or pulse-stretch = 100BASE-FX activity present.
20
21
22
Force LED Off
Force LED On
Fast Link Fail
1: De-asserts the LED.
0: Asserts the LED. LED pulsing is disabled in this mode.
1: Enable fast link fail on the LED pin
0: Disable
3.13.3 LED Behavior
Several LED behaviors can be programmed into the VSC8504-01. Use the settings in register 30 and
19E1 to program LED behavior, which includes the following.
LED Combine Enables an LED to display the status for a combination of primary and secondary
modes. This can be enabled or disabled for each LED pin. For example, a copper link running in
1000BASE-T mode and activity present can be displayed with one LED by configuring an LED pin to
Link1000/Activity mode. The LED asserts when linked to a 1000BASE-T partner and also blinks or
performs pulse-stretch when activity is either transmitted by the PHY or received by the Link Partner.
When disabled, the combine feature only provides status of the selected primary function. In this
example, only Link1000 asserts the LED, and the secondary mode, activity, does not display when the
combine feature is disabled.
LED Blink or Pulse-Stretch This behavior is used for activity and collision indication. This can be
uniquely configured for each LED pin. Activity and collision events can occur randomly and intermittently
throughout the link-up period. Blink is a 50% duty cycle oscillation of asserting and de-asserting an LED
pin. Pulse-stretch guarantees that an LED is asserted and de-asserted for a specific period of time when
activity is either present or not present. These rates can also be configured using a register setting.
Rate of LED Blink or Pulse-Stretch This behavior controls the LED blink rate or pulse-stretch length
when blink/pulse-stretch is enabled on an LED pin. The blink rate, which alternates between a high and
low voltage level at a 50% duty cycle, can be set to 2.5 Hz, 5 Hz, 10 Hz, or 20 Hz. For pulse-stretch, the
rate can be set to 50 ms, 100 ms, 200 ms, or 400 ms. The blink rate selection for PHY0 globally sets the
rate used for all LED pins on all PHY ports.
LED Pulsing Enable To provide additional power savings, the LEDs (when asserted) can be pulsed at
5 kHz, 20% duty cycle.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
27
Functional Descriptions
LED Blink After Reset The LEDs will blink for one second after power-up and after any time all resets
have been de-asserted. This can be disabled through register 19E1, bit 11 = 0.
Fiber LED Disable This bit controls whether the LEDs indicate the fiber and copper status (default) or
the copper status only.
Pulse Programmable Control These bits add the ability to width and frequency of LED pulses. This
feature facilitates power reduction options.
Fast Link Failure For more information about this feature, see Fast Link Failure Indication, page 29.
3.13.4 Basic Serial LED Mode
Optionally, the VSC8504-01 can be configured so that access to all its LED signals is available through
two pins. This option is enabled by setting LED0 on PHY0 to serial LED mode in register 29, bits 3:0 to
0xD. When serial LED mode is enabled, the LED0_0 pin becomes the serial data pin, and the LED1_0
pin becomes the serial clock pin. All other LED pins can still be configured normally. The serial LED
mode clocks the 48 LED status bits on the rising edge of the serial clock.
The LED behavior settings can also be used in serial LED mode. The controls are used on a per-PHY
basis, where the LED combine and LED blink or pulse-stretch setting of LED0_n for each PHY is used to
control the behavior of each bit of the serial LED stream for each corresponding PHY. To configure LED
behavior, set device register 30.
The following table shows the 48-bit serial output bitstream of each LED signal. The individual signals
can be clocked in the following order.
Table 9 •
LED Serial Bitstream Order
Output
PHY0 PHY1 PHY2 PHY3
Link/activity
Link1000/activity
Link100/activity
Link10/activity
Fiber link/activity
Duplex/collision
Collision
1
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
2
3
4
5
6
7
Activity
8
Fiber activity
Tx activity
9
10
11
Rx activity
Autonegotiation fault 12
3.13.5 Enhanced Serial LED Mode
VSC8504-01 can be configured to output up to four LED signals per port on a serial stream that can be
de-serialized externally to drive LEDs on the system board. In enhanced serial LED mode, the port 0 and
port 1 LED output pins serve the following functions:
•
•
•
•
LED0_0/LED0_1: LED_DATA
LED1_0/LED1_1: LED_CLK
LED2_0/LED2_1: LED_LD
LED3_0/LED3_1: LED_PULSE
The serial LED_DATA is shifted out on the falling edge of LED_CLK and is latched in the external
serial-to-parallel converter on the rising edge of LED_CLK. The falling edge of LED_LD signal can be
used to shift the data from the shift register in the converter to the parallel output drive register. When a
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
28
Functional Descriptions
separate parallel output drive register is not used in the external serial-to-parallel converter, the LEDs will
blink at a high frequency as the data bits are being shifted through, which may be undesirable. LED pin
functionality is controlled by setting register 25G, bits 7:1.
The LED_PULSE signal provides a 5 kHz pulse stream whose duty cycle can be modulated to turn on/off
LEDs at a high rate. This signal can be tied to the output enable signal of the serial-to-parallel converter
to provide the LED dimming functionality to save energy. The LED_PULSE duty cycle is controlled by
setting register 25G, bits 15:8.
3.13.6 LED Port Swapping
For additional hardware configurations, the VSC8504-01 can have its LED port order swapped. This is a
useful feature to help simplify PCB layout design. Register 25G bit 0 controls the LED port swapping
mode.
Note: LED port swapping only applies to the parallel LED outputs and does not affect the serial LED outputs.
3.14 Fast Link Failure Indication
To aid Synchronous Ethernet applications, the VSC8504-01 can indicate the onset of a link failure in less
than 1 ms (worst-case <3 ms). By comparison, the IEEE 802.3 standard establishes a delay of up to
750 ms before indicating that a 1000BASE-T link is no longer present. A fast link failure indication is
critical to support ports used in a synchronization timing link application. The fast link failure indication
works for all copper media speeds, but not for fiber media. Fast link failure is supported for each PHY
port through the GPIO9/FASTLINK-FAIL pin.
Note: For all links except 1000BASE-T, the fast link failure indication matches the link status register (address
1, bit 2). For 1000BASE-T links, the link failure is based on a circuit that analyzes the integrity of the link,
and at the indication of failure, will assert.
Note: The Fast Link Failure Indication should not be used when EEE is enabled on a link.
3.15 Integrated Two-Wire Serial Multiplexer
The VSC8504-01 includes an integrated quad two-wire serial multiplexer (MUX), eliminating the need for
an external two-wire serial device for the control and status of SFP or PoE modules. There are five
two-wire serial controller pins: four clocks and one shared data pin. Each SFP or PoE connects to the
multipurpose GPIO[7:4]_I2C_SCL_[3:0] and GPIO8/I2C_SDA device pins, which must be configured to
the corresponding two-wire serial function. For more information about configuring the pins, see
Two-Wire Serial MUX Control 1, page 83. For SFP modules, VSC8504-01 can also provide control for
the MODULE_DETECT and TX_DIS module pins using the multipurpose LED and GPIO pins.
Figure 30 • Two-Wire Serial MUX with SFP Control and Status
SDA
SFP0
SCL
Management
Interface
SDA
SFP1
MDC
SCL
Integrated I2C
Mux
MDIO
SDA
SCL
GPIO4/I2C_SCL_0
GPIO5/I2C_SCL_1
GPIO6/I2C_SCL_2
GPIO7/I2C_SCL_3
SFP2
SFP3
GPIO8/I2C_SDA
SDA
SCL
PHY
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
29
Functional Descriptions
3.15.1 Read/Write Access Using the Two-Wire Serial MUX
Using the integrated two-wire serial MUX, the VSC8504-01 device can read and write to an SFP or PoE
module through the SCL and SDA pins. If the ability is required to write to the slave two-wire serial
device, refer to the device's specific datasheet for more information.
Note: The VSC8504-01 device does not automatically increment the two-wire serial address. Each desired
address must be intentionally set.
Main control of the integrated two-wire serial MUX is available through register 20G. The two-wire serial
MUX pins are enabled or disabled using register 20G bits 3:0. Register 20G bits 15:9 set the two-wire
serial device address (the default is 0xA0). Using register 20G bits 5:4, the two-wire serial frequency can
be changed from 100 kHz to other speeds, such as 50 kHz, 100 kHz (the default), 400 kHz, and 2 MHz.
Registers 21G and 22G provide status and control of the read/write process. The following illustration
shows the read and write register flow.
Figure 31 • Two-Wire Serial MUX Read and Write Register Flow
Start
21G.15 = 0
Wait for
Ready
Read Data =
22G.15:8
21G.9 = 1
21G.15 = 1
21G.15 = 1
21G.11:10 = PHY port to Write
21G.7:0 = Address to Write
21G.8 = 1
Write
SFP
Data
Wait for
Ready
Read or Write
22G.7:0 = Data to Write
21G.15 = 0
Read SFP Data
21G.11:10 = PHY port to Read
21G.7:0 = Address to Read
21G.8 = 1
21G.9 = 1
To read a value from a specific address of the two-wire serial slave device:
1. Read the VSC8504-01 device register 21G bit 15, and ensure that it is set.
2. Write the PHY port address to be read to register 21G bits 11:10.
3. Write the two-wire serial address to be read to register 21G bits 7:0.
4. Set both register 21G bits 8 and 9 to 1.
5. When register 21G bit 15 changes to 1, read the 8-bit data value found at register 22G bits 15:8.
This is the contents of the address just read by the PHY.
To write a value to a specific address of the two-wire serial slave device:
1. Read the VSC8504-01 device register 21G bit 15 and ensure that it is set.
2. Write the PHY port address to be written to register 21G bits 11:10.
3. Write the address to be written to register 21G bits 7:0.
4. Set register 21 bit 8 to 0.
5. Set register 22G bits 7:0 with the 8-bit value to be written to the slave device.
6. Set register 21G bit 9 to 1.
To avoid collisions during read and write transactions on the two-wire serial bus, always wait until register
21G bit 15 changes to 1 before performing another two-wire serial read or write operation.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
30
Functional Descriptions
3.16 GPIO Pins
The VSC8504-01 provides 18 multiplexed general purpose input/output (GPIO) pins. All device GPIO
pins and their behavior are controlled using registers. The following table shows an overview of the
register controls for GPIO pins. For more information, see General Purpose Registers, page 78.
Table 10 • Register Bits for GPIO Control and Status
GPIO Pin
GPIO_ctrl
13G.1:0
GPIO Input GPIO Output GPIO Output Enable
GPIO0/SIGDET0
GPIO1/SIGDET1
GPIO2/SIGDET2
GPIO3/SIGDET3
GPIO4/I2C_SCL_0
GPIO5/I2C_SCL_1
GPIO6/I2C_SCL_2
GPIO7/I2C_SCL_3
GPIO8/I2C_SDA
GPIO9/FASTLINK_FAIL
15G.0
15G.1
15G.2
15G.3
15G.4
15G.5
15G.6
15G.7
15G.8
15G.9
16G.0
16G.1
16G.2
16G.3
16G.4
16G.5
16G.6
16G.7
16G.8
16G.9
17G.0
17G.1
17G.2
17G.3
17G.4
17G.5
17G.6
17G.7
17G.8
17G.9
13G.3:2
13G.5:4
13G.7:6
13G.9:8.
13G.11:10
13G.13:12
13G.15:14
14G.1:0
14G.3:2
3.17 Testing Features
The VSC8504-01 device includes several testing features designed to facilitate performing system-level
debugging and in-system production testing. This section describes the available features.
3.17.1 Ethernet Packet Generator
The Ethernet packet generator (EPG) can be used at each of the 10/100/1000BASE-T speed settings for
copper Cat5 media and fiber media to isolate problems between the MAC and the VSC8504-01, or
between a locally connected PHY and its remote link partner. Enabling the EPG feature effectively
disables all MAC interface transmit pins and selects the EPG as the source for all data transmitted onto
the twisted pair interface. This feature is not used when the SerDes media is set to pass-through mode.
Important The EPG is intended for use with laboratory or in-system testing equipment only. Do not use
the EPG testing feature when the VSC8504-01 is connected to a live network.
To enable the VSC8504-01 EPG feature, set the device register bit 29E1.15 to 1.
When the EPG is enabled, packet loss occurs during transmission of packets from the MAC to the PHY.
However, the PHY receive output pins to the MAC are still active when the EPG is enabled. When it is
necessary to disable the MAC receive pins as well, set the register bit 0.10 to 1.
When the device register bit 29E1.14 is set to 1, the PHY begins transmitting Ethernet packets based on
the settings in registers 29E1 and 30E1. These registers set:
•
•
•
•
•
•
Source and destination addresses for each packet
Packet size
Interpacket gap
FCS state
Transmit duration
Payload pattern
When register bit 29E1.13 is set to 0, register bit 29E1.14 is cleared automatically after 30,000,000
packets are transmitted.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
31
Functional Descriptions
3.17.2 CRC Counters
Two sets of cyclical redundancy check (CRC) counters are available in all PHYs in VSC8504-01. One set
monitors traffic on the copper interface and the other set monitors traffic on the SerDes interface.
The device CRC counters operate in the 100BASE-FX/1000BASE-X over SerDes mode as well as in the
10/100/1000BASE-T mode as follows:
After receiving a packet on the media interface, register bit 15 in register 18E1 or register 28E3 is set and
cleared after being read.
The packet then is counted by either the good CRC counter or the bad CRC counter.
Both CRC counters are also automatically cleared when read.
The good CRC counter’s highest value is 9,999 packets. After this value is reached, the counter clears
on the 10,000th packet and continues to count additional packets beyond that value. The bad CRC
counter stops counting when it reaches its maximum counter limit of 255 packets.
3.17.2.1 Copper Interface CRC Counters
Two separate CRC counters are available and reside between the copper interface PCSs and SerDes
MAC interface. There is a 14-bit good CRC counter available through register bits 18E1.13:0 and a
separate 8-bit bad CRC counter available in register bits 23E1.7:0.
3.17.2.2 SerDes Interface CRC Counters
Two separate CRC counters are available and reside between the SerDes media interface PCSs and
SerDes MAC interface. There is a 14-bit good CRC counter available through register bits 28E3.13:0 and
a separate 8-bit bad CRC counter available in register bits 29E3.7:0.
3.17.2.3 SerDes Fiber Media Transmit Counters
Two fiber media transmit counters are available to verify packets being transmitted on the fiber media.
Register bits 21E3.13:0 are the good CRC packet counters and register bits 22E3.7:0 are the CRC error
counters.
3.17.3 Far-End Loopback
The far-end loopback testing feature is enabled by setting register bit 23.3 to 1. When enabled, it forces
incoming data from a link partner on the current media interface, into the MAC interface of the PHY, to be
retransmitted back to the link partner on the media interface as shown in the following illustration. In
addition, the incoming data also appears on the receive data pins of the MAC interface. Data present on
the transmit data pins of the MAC interface is ignored when using this testing feature.
Figure 32 • Far-End Loopback Diagram
PHY_port_n
RX
RXD
TXD
Link Partner
MAC
TX
3.17.4 Near-End Loopback
When the near-end loopback testing feature is enabled, transmitted data (TXD) is looped back in the
PCS block onto the receive data signals (RXD), as shown in the following illustration. When using this
testing feature, no data is transmitted over the network. To enable near-end loopback, set the device
register bit 0.14 to 1.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
32
Functional Descriptions
Figure 33 • Near-End Loopback Diagram
PHY_port_n
RX
RXD
TXD
Link Partner
TX
MAC
3.17.5 Connector Loopback
The connector loopback testing feature allows the twisted pair interface to be looped back externally.
When using this feature, the PHY must be connected to a loopback connector or a loopback cable.
Connect pair A to pair B, and pair C to pair D, as shown in the following illustration. The connector
loopback feature functions at all available interface speeds.
Figure 34 • Connector Loopback Diagram
A
B
C
D
RXD
TXD
Cat5
PHY_port_n
MAC
When using the connector loopback testing feature, the device autonegotiation, speed, and duplex
configuration is set using device registers 0, 4, and 9. For 1000BASE-T connector loopback, the
following additional writes are required. Execute the additional writes in the following order:
1. Enable the 1000BASE-T connector loopback. Set register bit 24.0 to 1.
2. Disable pair swap correction. Set register bit 18.5 to 1.
3.17.6 SerDes Loopbacks
For test purposes, the SerDes and SerDes macro interfaces provides several data loops. The following
illustration shows the SerDes loopbacks.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
33
Functional Descriptions
Figure 35 • Data Loops of the SerDes Macro
n
bit IF
n
bit IF
SLIVER
Digital interface, configuration, and control
logic including synchronous Ethernet clock tree
D
Q >
Facility Loop
HS-ref. clock
HS-ref. clock
RC-PLL
DES
n:1
SER
1:n
Equipment-Loop
Input-Loop
OB
IB
Analog Services Modules
(BIAS, clk tree buffers,
ESD protection
)
RX
TX
3.17.6.1 SGMII Mode
When the MAC interface is configured in SGMII mode, write the following 16-bit value to register 18G:
Bits 15:12 0x9
Bits 11:8: Port address (0x0 to 0x3)
Bits 7:4: Loopback type
Bits 3:0: 0x2
where loopback type is:
0x0: No loopback
0x2: Input loopback
0x4: Facility loopback
0x8: Equipment loopback
3.17.6.2 QSGMII Mode
When the MAC interface is configured in QSGMII mode, write the following 16-bit value to register 18G:
Bits 15:12 0x9
Bits 11:8: Port address (0x0)
Bits 7:4: Loopback type
Bits 3:0: 0x2
where loopback type is:
0x0: No loopback
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
34
Functional Descriptions
0x2: Input loopback
0x4: Facility loopback
0x8: Equipment loopback
Note: Loopback configuration affects all ports associated with a QSGMII. Individual port loopback within a
QSGMII is not possible.
3.17.6.3 Fiber Media Port Mode
When the SerDes is configured as a fiber media port, write the following 16-bit value to register 18G:
Bits 15:12: 0x8
Bits 11:8: Port address
Bits 7:4: Loopback type
Bits 3:0: 0x2
where port address is:
0x1: Fiber0 port
0x2: Fiber1 port
0x4: Fiber2 port
0x8: Fiber3 port
Port addresses for fiber media SerDes can be OR'ed together to address multiple ports using a single
command. bit 18G.15 will be cleared when the internal configuration is complete.
3.17.6.4 Facility Loop
The recovered and de-multiplexer deserializer data output is looped back to the serializer data input and
replaces the data delivered by the digital core. This test loop provides the possibility to test the complete
analog macro data path from outside including input buffer, clock and data recovery, serialization and
output buffer. The data received by the input buffer must be transmitted by the output buffer after some
delay.
Additional configuration of the macro is required for facility loopback mode. When entering facility
loopback mode, the set = 1 option should be run; when exiting facility loopback mode, the set = 0 option
should be run.
PhyWrite(PhyBaseAddr, 31, 0x0010);
PhyWrite(PhyBaseAddr, 18, 0x8s03);
// where “s” is the physical address of the SerDes macro
PhyWrite(PhyBaseAddr, 18, 0xd7cb);
PhyWrite(PhyBaseAddr, 18, 0x8007);
tmp1 = PhyRead(PhyBaseAddr, 18);
tmp2 = tmp1 & 0x0ff0;
if (set)
tmp3 = tmp2 | 0x0010;
else
tmp3 = tmp2 & 0x0fe0;
tmp4 = tmp3 | 0x8006;
PhyWrite(PhyBaseAddr, 18, tmp4);
if (SGMII)
PhyWrite(PhyBaseAddr, 18, 0x9p40);
// where “p” is the logical address of the SGMII interface
else
PhyWrite(PhyBaseAddr, 18, 0x8p40);
// where “p” is the logical address of the Fiber media interface
// PhyBaseAddr is the 5-bit base address of the internal PHYs.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
35
Functional Descriptions
// The upper 3 bits are set by the PHYADD[4:2] pins and the
// lower 2 bits are 0.
Additional configuration of the enhanced SerDes macro is required for facility loopback mode. When
entering facility loopback mode, the set = 1 option should be run; when exiting facility loopback mode,
the set = 0 option should be run.
PhyWrite(PhyBaseAddr, 31, 0x0010);
PhyWrite(PhyBaseAddr, 18, 0x8013);
PhyWrite(PhyBaseAddr, 18, 0xd7cb);
PhyWrite(PhyBaseAddr, 18, 0x8007);
tmp1 = PhyRead(PhyBaseAddr, 18);
tmp2 = tmp1 & 0x0ff0;
if (set)
tmp3 = tmp2 | 0x0100;
else
tmp3 = tmp2 & 0x0ef0;
tmp4 = tmp3 | 0x8006;
PhyWrite(PhyBaseAddr, 18, tmp4);
PhyWrite(PhyBaseAddr, 18, 0x9c40);
// PhyBaseAddr is the 5-bit base address of the internal PHYs.
// The upper 3 bits are set by the PHYADD[4:2] pins and the
// lower 2 bits are 0.
3.17.6.5 Equipment Loop
The 1-bit data stream at the serializer output is looped back to the deserializer and replaces the received
data stream from the input buffer. This test loop provides the possibility to verify the digital data path
internally. The transmit data goes through the serialization, the clock and data recovery and
deserialization before the data is fed back to the digital core.
Note: After entering equipment loopback mode, the following workaround should be run with set = 1 option in
case external signal is not present; when exiting equipment loopback mode, the set = 0 option should be
run:
SGMII/QSGMII SerDes
PhyWrite(<phy>, 31, 0x52b5);
PhyWrite(<phy>, 16, 0xa68c);
tmp17 = PhyRead(<phy>,17);
if (set)
tmp17 |= 0x0010; //Set SigDet as desired, Set bit 4
else // clear SigDet
tmp17 &= 0xffef; //Clear SigDet, bit 4
PhyWrite(<phy>, 17, tmp17);
PhyWrite(<phy>, 16, 0x868c);
PhyWrite(<phy>, 31, 0x0);
Fiber media SerDes
PhyWrite(<phy>, 31, 0x52b5);
PhyWrite(<phy>, 16, 0xa68a);
tmp17 = PhyRead(<phy>,17);
if (set)
tmp17 |= 0x0010; //Set SigDet as desired, Set bit 4
else // clear SigDet
tmp17 &= 0xffef; //Clear SigDet, bit 4
PhyWrite(<phy>, 17, tmp17);
PhyWrite(<phy>, 16, 0x868a);
PhyWrite(<phy>, 31, 0x0);
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
36
Functional Descriptions
3.17.6.6 Input Loop
The received 1-bit data stream of the input buffer is looped back asynchronously to the output buffer. This
test loop provides the possibility to test only the analog parts of the SGMII interface because only the
input and output buffer are part of this loop.
Note: When the enhanced SerDes macro is in input loopback, the output is inverted relative to the input.
The following table shows the SerDes macro address map.
Table 11 • SerDes Macro Address Map
SerDes Macro
SerDes0
SerDes1
SerDes2
SerDes3
SerDes4
SerDes5
SerDes6
Physical Address (s)
Interface Logical Type (p)
Address
0x1
0x0
0x1
0x2
0x3
0x4
0x5
0x6
Fiber0
SGMII1
Fiber1
SGMII2
Fiber2
SGMII3
Fiber3
0x1
0x2
0x2
0x4
0x3
0x8
3.17.7 VeriPHY Cable Diagnostics
The VSC8504-01 includes a comprehensive suite of cable diagnostic functions that are available using
SMI reads and writes. These functions enable a variety of cable operating conditions and status to be
accessed and checked. The VeriPHY suite has the ability to identify the cable length and operating
conditions and to isolate a variety of common faults that can occur on the Cat5 twisted pair cabling.
Note: When a link is established on the twisted pair interface in the 1000BASE-T mode, VeriPHY can run
without disrupting the link or disrupting any data transfer. However, when a link is established in
100BASE-TX or 10BASE-T modes, VeriPHY causes the link to drop while the diagnostics are running.
After diagnostics are finished, the link is re-established.
The following diagnostic functions are part of the VeriPHY suite:
•
•
•
Detecting coupling between cable pairs
Detecting cable pair termination
Determining cable length
3.17.7.1 Coupling Between Cable Pairs
Shorted wires, improper termination, or high crosstalk resulting from an incorrect wire map can cause
error conditions, such as anomalous coupling between cable pairs. These conditions can prevent the
device from establishing a link in any speed.
3.17.7.2 Cable Pair Termination
Proper termination of Cat5 cable requires a 100 Ω differential impedance between the positive and
negative cable terminals. IEEE 802.3 allows for a termination of 115 Ω maximum and 85 Ω minimum.
VeriPHY diagnostics can report anomalous termination that falls outside of this range. The diagnostics
can also determine the presence of an open or shorted cable pair.
3.17.7.3 Cable Length
When the Cat5 cable in an installation is properly terminated, VeriPHY reports the approximate cable
length in meters. If there is a cable fault the distance to the fault is reported.
3.17.7.4 Mean Square Error Noise
The average absolute error can be read out when either a 100BASE-TX or 1000BASE-T link is
established. In the case of 1000BASE-T link, there are four average absolute error terms, one for each
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
37
Functional Descriptions
twisted pair over which signal is received. Use the following script to read average absolute error for
100BASE-TX:
PhyWrite(<phy>, 31, 0x52b5);
PhyWrite(<phy>, 16, 0xa3c0);
PhyRead(<phy>, 16);
tmp17 = PhyRead(<phy>, 17);
tmp18 = PhyRead(<phy>, 18);
mse = (tmp18 << 4) | (tmp17 >> 12);
PhyWrite(<phy>, 31, 0);
The returned average absolute error is in units of 1/2,048 and can be found in the mse variable.
PhyWrite(<phy>, 31, 0x52b5);
PhyWrite(<phy>, 16, 0xa3c0);
PhyRead(<phy>, 16);
tmp17 = PhyRead(<phy>, 17);
tmp18 = PhyRead(<phy>, 18);
mseA = (tmp18 << 4) | (tmp17 >> 12);
mseB = tmp17 & 0x0fff;
PhyWrite(<phy>, 16, 0xa3c2);
PhyRead(<phy>, 16);
tmp17 = PhyRead(<phy>, 17);
tmp18 = PhyRead(<phy>, 18);
mseC = (tmp18 << 4) | (tmp17 >> 12);
mseD = tmp17 & 0x0fff;
PhyWrite(<phy>, 31, 0);
The returned average absolute error is in units of 1/2,048 and can be found in the mseA, mseB, mseC,
and mseD variables for each twisted pair.
3.17.8 JTAG Boundary Scan
The VSC8504-01 supports the test access port (TAP) and boundary scan architecture described in
IEEE 1149.1. The device includes an IEEE 1149.1-compliant test interface, referred to as a JTAG TAP
interface.
The JTAG boundary scan logic on the VSC8504-01, accessed using its TAP interface, consists of a
boundary scan register and other logic control blocks. The TAP controller includes all IEEE-required
signals (TMS, TCK, TDI, and TDO), in addition to the optional asynchronous reset signal TRST. The
following illustration shows the TAP and boundary scan architecture.
Important When JTAG is not in use, the TRST pin must be tied to ground with a pull-down resistor for
normal operation.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
38
Functional Descriptions
Figure 36 • Test Access Port and Boundary Scan Architecture
Boundary Scan
Register
Device Identification
Register
Bypass Register
TDO
MUX,
DFF
Control
Instruction Register,
Instruction Decode
Control
TDI
TMS
Control
Select
Test Access Port
Controller
NTRST
TCK
TDO Enable
After a TAP reset, the device identification register is serially connected between TDI and TDO by
default. The TAP instruction register is loaded either from a shift register when a new instruction is shifted
in, or, if there is no new instruction in the shift register, a default value of 6'b100000 (IDCODE) is loaded.
Using this method, there is always a valid code in the instruction register, and the problem of toggling
instruction bits during a shift is avoided. Unused codes are mapped to the BYPASS instruction.
3.17.9 JTAG Instruction Codes
The VSC8504-01 supports the following instruction codes:
Table 12 • JTAG Instruction Codes
Instruction Code Description
BYPASS
The bypass register contains a single shift-register stage and is
used to provide a minimum-length serial path (one TCK clock
period) between TDI and TDO to bypass the device when no test
operation is required.
CLAMP
Allows the state of the signals driven from the component pins to
be determined from the boundary scan register while the bypass
register is selected as the serial path between TDI and TDO.
While the CLAMP instruction is selected, the signals driven from
the component pins do not change.
EXTEST
Allows tests of the off-chip circuitry and board-level
interconnections by sampling input pins and loading data onto
output pins. Outputs are driven by the contents of the boundary
scan cells, which have to be updated with valid values, with the
PRELOAD instruction, prior to the EXTEST instruction.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
39
Functional Descriptions
Table 12 • JTAG Instruction Codes (continued)
Instruction Code Description
HIGHZ
Places the component in a state in which all of its system logic
outputs are placed in a high-impedance state. In this state, an in-
circuit test system can drive signals onto the connections normally
driven by a component output without incurring a risk of damage to
the component. This makes it possible to use a board where not
all of the components are compatible with the IEEE 1149.1
standard.
IDCODE
Provides the version number (bits 31:28), device family ID (bits
27:12), and the manufacturer identity (bits 11:1) to be serially read
from the device.
SAMPLE/PRELOA Allows a snapshot of inputs and outputs during normal system
D
operation to be taken and examined. It also allows data values to
be loaded into the boundary scan cells prior to the selection of
other boundary scan test instructions.
USERCODE
Provides the version number (bits 31:28), part number (bits 27:12),
and the manufacturer identity (bits 11:1) to be serially read from
the device.
The following tables provide information about the IDCODE and USERCODE binary values stored in the
device JTAG registers.
Table 13 • IDCODE JTAG Device Identification Register Descriptions
Description Device Version Family ID
Bit field 31–28 27–12
Binary value 0000
Manufacturing Identity
LSB
11–1
0
1
1000 0101 0111 0100 000 0111 0100
Table 14 • USERCODE JTAG Device Identification Register Descriptions
Description Device Version Model Number
Bit field 31–28 27–12
Binary value 0010
Manufacturing Identity
LSB
11–1
0
1
1000 0101 0111 0100 000 0111 0100
The following table provides information about the location and IEEE compliance of the JTAG instruction
codes used in the VSC8504-01. Instructions not explicitly listed in the table are reserved. For more
information about these IEEE specifications, visit the IEEE Web site at www.IEEE.org.
Table 15 • JTAG Instruction Code IEEE Compliance
Register
Instruction
Code
Selected Register
Boundary Scan
Boundary Scan
Width
IEEE 1149.1
Mandatory
Mandatory
EXTEST
6'b000000
161
SAMPLE/PRELOA 6'b000001
D
161
IDCODE
USERCODE
CLAMP
6'b100000
6'b100101
6'b000010
6'b000101
6'b111111
Device Identification
Device Identification
Bypass Register
Bypass Register
Bypass Register
32
32
1
Optional
Optional
Optional
Optional
Mandatory
HIGHZ
1
BYPASS
1
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
40
Functional Descriptions
3.17.10 Boundary Scan Register Cell Order
All inputs and outputs are observed in the boundary scan register cells. All outputs are additionally driven
by the contents of boundary scan register cells. Bidirectional pins have all three related boundary scan
register cells: input, output, and control.
The complete boundary scan cell order is available as a BSDL file format on the Microsemi Web site at
www.Microsemi.com.
3.18 100BASE-FX Halt Code Transmission and Reception
The VSC8504-01 device supports transmission and reception of halt code words in 100BASE-FX mode.
There are three separate scripts provided to initiate transmission of halt code words, stop transmission of
halt code words and detect reception of halt code words. Use the following scripts to implement each of
these functions:
Sending the HALT codeword:
PhyWrite(<phy>, 31, 0x52b5);
PhyWrite(<phy>, 16, 0xac82);
reg18 = PhyRead(<phy>, 18);
reg18 = (reg18 & 0xf0) | 0x0c;
PhyWrite(<phy>, 18, reg18);
PhyWrite(<phy>, 17, 0xe739);
PhyWrite(<phy>, 16, 0x8c82);
PhyWrite< <phy>, 16, 0xbe80);
reg17 = PhyRead(<phy>, 17);
reg18 = PhyRead(<phy>, 18);
reg17 = reg17 | 0x0040;
PhyWrite(<phy>, 18, reg18);
PhyWrite(<phy>, 17, reg17);
PhyWrite(<phy>, 16, 0x9e80);
PhyWrite(<phy>, 31, 0);
Stop sending the HALT codeword:
PhyWrite(<phy>, 31, 0x52b5);
PhyWrite< <phy>, 16, 0xbe80);
reg17 = PhyRead(<phy>, 17);
reg18 = PhyRead(<phy>, 18);
reg17 = reg17 & ~0x0040;
PhyWrite(<phy>, 18, reg18);
PhyWrite(<phy>, 17, reg17);
PhyWrite(<phy>, 16, 0x9e80);
PhyWrite(<phy>, 31, 0);
Detecting whether the HALT codeword is being sent by the link partner:
long patternset[5] = {
0xce739,
0xe739c,
0x739ce,
0x39ce7,
0x9ce73
};
Turning on the pattern checker:
PhyWrite(<phy>, 31, 0x52b5);
PhyWrite(<phy>, 16, 0xbe80);
reg18 = PhyRead(<phy>, 18);
reg17 = PhyRead(<phy>, 17);
reg17 = reg17 | 4;
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
41
Functional Descriptions
PhyWrite(<phy>, 18, reg18);
PhyWrite(<phy>, 17, reg17);
PhyWrite(<phy>, 16, 0x9e80);
Sweeping through all five pattern shifts checking for a match:
for (i = 0, matchfailed = 1; i < 5 && matchfailed; ++i) {
PhyWrite(<phy>, 16, 0xac84);
reg18 = PhyRead(<phy>, 18);
reg18 = (reg18 & 0xf0) | (patternset[i] >> 16)
PhyWrite(<phy>, 18, reg18);
PhyWrite(<phy>, 17, patternset[i] & 0xffff);
PhyWrite(<phy>, 16, 0x8c84);
PhyWrite(<phy>, 16, 0xbe84); // Dummy read to clear latched mismatch
PhyWrite(<phy>, 16, 0xbe84); // Read pattern check failure status
matchfailed = PhyRead(<phy>, 17) & 1; // Extract pattern check failure status
}
Turning off the pattern checker:
PhyWrite(<phy>, 16, 0xbe80);
reg18 = PhyRead(<phy>, 18);
reg17 = PhyRead(<phy>, 17);
reg17 = reg17 & ~4;
PhyWrite(<phy>, 18, reg18);
PhyWrite(<phy>, 17, reg17);
PhyWrite(<phy>, 16, 0x9e80);
PhyWrite(<phy>, 31, 0);
HALT_codeword_detected =!matchfailed;
3.19 Configuration
The VSC8504-01 can be configured by setting internal memory registers using the management
interface. To configure the device, perform the following steps:
1. COMA_MODE active, drive high (optional).
2. Apply power.
3. Apply RefClk.
4. Release reset, drive high. Power and clock must be stable before releasing reset.
5. Wait 120 ms minimum.
6. Apply patch from PHY_API (required for production released optional for board testing).
7. Configure register 19G for MAC mode (to access register 19G, register 31 must be 0x10). Read
register 19G. Set bits 15:14, MAC configuration as follows:
00: SGMII
01: QSGMII
10: Reserved
11: Reserved
Write new register 19G.
8. Configure register 18G for MAC on all 4 PHYs write:
SGMII: 0x80F0
QSGMII: 0x80E0
Read register 18G until bit 15 equals 0.
9. If Fiber Media on all 4 PHYs configure register 18G by writing:
Media 1000BASE-X: 0x8FC1
Media 100BASE-FX: 0x8FD1
10. If Fiber Media read register 18G till bit 15 equals 0.
11. Configure register 23 for MAC and Media mode (to access register 23, register 31 must be 0). Read
register 23. Set bits 10:8 as follows:
000: Copper
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
42
Functional Descriptions
010: 1000BASE-X
011: 100BASE-FX
Write new register 23.
12. Software reset. Read register 0 (to access register 0, register 31 must be 0). Set bit 15 to 1.
Write new register 0.
13. Read register 0 until bit 15 equals 0.
14. Release the COMA_MODE pin, drive low (only necessary if COMA_MODE pin is driven high or
unconnected).
3.19.1 Initialization
The COMA_MODE pin provides an optional feature that may be used to control when the PHYs become
active. The typical usage is to keep the PHYs from becoming active before they have been fully
initialized. For more information, see Configuration, page 42. By not being active until after complete
initialization keeps links from going up and down. Alternatively the COMA_MODE pin may be connected
low (ground) and the PHYs will be fully active once out of reset.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
43
Registers
4
Registers
This section provides information about how to configure the VSC8504-01 using its internal memory
registers and the management interface. The registers marked reserved and factory test should not be
read or written to, because doing so may produce undesired effects.
The default value documented for registers is based on the value at reset; however, in some cases, that
value may change immediately after reset.
The access type for each register is shown using the following abbreviations:
•
•
•
•
•
•
RO: Read Only
ROCR: Read Only, Clear on Read
RO/LH: Read Only, Latch High
RO/LL: Read Only, Latch Low
R/W: Read and Write
RWSC: Read Write Self Clearing
The VSC8504-01 uses several different types of registers:
•
•
•
•
IEEE Clause 22 device registers with addresses from 0 to 31
Three pages of extended registers with addresses from 16E1–30E1, 16E2–30E2, and 16E3–30E3
General-purpose registers with addresses from 0G to 30G
IEEE Clause 45 devices registers accessible through the Clause 22 registers 13 and 14 to support
IEEE 802.3az-2010 energy efficient Ethernet registers
The following illustration shows the relationship between the device registers and their address spaces.
Figure 37 • Register Space Diagram
0
1
2
3
.
0G
1G
2G
3G
.
.
.
Clause 45
Registers
IEEE 802.3
Standard
.
Registers
.
13
14
15
.
.
15G
General Purpose
Registers
16
17
18
19
.
16G
17G
18G
19G
.
.
.
16E1
17E1
18E1
19E1
.
.
.
16E2
17E2
18E2
19E2
.
.
.
16E3
17E3
18E3
19E3
.
.
.
Extended
Registers 1
Extended
Registers 2
Extended
Registers 3
Main Registers
.
.
.
.
.
.
.
.
.
.
.
.
30
30G
30E1
30E2
30E3
31
0x0000
0x0010
0x0001
0x0002
0x0003
Reserved Registers For main registers 16–31, extended registers 16E1–30E1, 16E2–30E2, 16E3–
30E3, and general purpose registers 0G–30G, any bits marked as Reserved should be processed as
read-only and their states as undefined.
Reserved Bits In writing to registers with reserved bits, use a read-modify-then-write technique, where
the entire register is read but only the intended bits to be changed are modified. Reserved bits cannot be
changed and their read state cannot be considered static or unchanging.
4.1
Register and Bit Conventions
Registers are referred to by their address and bit number in decimal notation. A range of bits is indicated
with a colon. For example, a reference to address 26, bits 15 through 14 is shown as 26.15:14.
A register with an E and a number attached (example 27E1) means it is a register contained within
extended register page number 1. A register with a G attached (example 13G) means it is a GPIO page
register.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
44
Registers
Bit numbering follows the IEEE standard with bit 15 being the most significant bit and bit 0 being the least
significant bit.
4.2
IEEE 802.3 and Main Registers
In the VSC8504-01, the page space of the standard registers consists of the IEEE 802.3 standard
registers and the Microsemi standard registers. The following table lists the names of the registers
associated with the addresses as specified by IEEE 802.3.
Table 16 • IEEE 802.3 Registers
Address Name
0
Mode Control
1
Mode Status
2
PHY Identifier 1
3
PHY Identifier 2
4
Autonegotiation Advertisement
Autonegotiation Link Partner Ability
Autonegotiation Expansion
Autonegotiation Next-Page Transmit
Autonegotiation Link Partner Next-Page Receive
1000BASE-T Control
5
6
7
8
9
10
1000BASE-T Status
11–12
13
Reserved
Clause 45 Access Registers from IEEE 802.3
Table 22-6 and 22.24.3.11-12 and Annex 22D
14
15
Clause 45 Access Registers from IEEE 802.3
Table 22-6 and 22.24.3.11-12 and Annex 22D
1000BASE-T Status Extension 1
The following table lists the names of the registers in the main page space of the device. These registers
are accessible only when register address 31 is set to 0x0000.
Table 17 • Main Registers
Address Name
16
17
18
19
20
21
22
23
24
25
26
100BASE-TX status extension
1000BASE-T status extension 2
Bypass control
Error Counter 1
Error Counter 2
Error Counter 3
Extended control and status
Extended PHY control 1
Extended PHY control 2
Interrupt mask
Interrupt status
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
45
Registers
Table 17 • Main Registers (continued)
Address Name
27
28
29
30
31
Reserved
Auxiliary control and status
LED mode select
LED behavior
Extended register page access
4.2.1
Mode Control
The device register at memory address 0 controls several aspects of VSC8504-01 functionality. The
following table shows the available bit settings in this register and what they control.
Table 18 • Mode Control, Address 0 (0x00)
Bit Name
Access Description
Default
15 Software reset
R/W
Self-clearing. Restores all serial management
interface (SMI) registers to default state,
except for sticky and super-sticky bits.
1: Reset asserted.
0
0: Reset de-asserted. Wait [X] after setting this
bit to initiate another SMI register access.
14 Loopback
R/W
1: Loopback enabled.
0
0
1
0: Loopback disabled. When loop back is
enabled, the device functions at the current
speed setting and with the current duplex
mode setting (bits 6, 8, and 13 of this register).
13 Forced speed selection R/W
LSB
Least significant bit. MSB is bit 6.
00: 10 Mbps.
01: 100 Mbps.
10: 1000 Mbps.
11: Reserved.
12 Autonegotiation enable R/W
1: Autonegotiation enabled.
0: Autonegotiation disabled.
11 Power-down
10 Isolate
R/W
R/W
1: Power-down enabled.
0
0
1: Disconnect the MAC-side interface of the
device from the rest of the datapath. Traffic
entering the PHY from either the MAC-side or
media-side interface will terminate inside the
PHY.
9
8
Restart autonegotiation R/W
Self-clearing bit.
1: Restart autonegotiation on media interface.
0
0
Duplex
R/W
R/W
1: Full-duplex.
0: Half-duplex.
7
6
Collision test enable
1: Collision test enabled.
0
Forced speed selection R/W
MSB
Most significant bit. LSB is bit 13.(1)
00: 10 Mbps.
10
01: 100 Mbps.
10: 1000 Mbps.
11: Reserved.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
46
Registers
Table 18 • Mode Control, Address 0 (0x00) (continued)
Bit Name
Access Description
R/W When bit 0.12 = 1 or bit 0.8 = 0, this bit is
Default
5
Unidirectional enable
0
ignored. When bit 0.12 = 0 and bit 0.8 = 1, the
behavior is as follows:
1: Enable transmit from media independent
interface regardless of whether the PHY has
determined that a valid link has been
established.
0: Enable transmit from media independent
interface only when the PHY has determined
that a valid link has been established.
Note: This bit is only applicable in
100BASE-FX and 1000BASE-X
fiber media modes.
4:0 Reserved
Reserved.
00000
1. Before selecting the 1000 Mbps forced speed mode, manually configure the PHY as master or slave by
setting bit 11 in register 9 (1000BASE-T Control). Each time the link drops, the PHY needs to be powered
down manually to enable it to link up again using the master/slave setting specified in register 9.11.
4.2.2
Mode Status
The register at address 1 in the device main registers space allows you to read the currently enabled
mode setting. The following table shows possible readouts of this register.
Table 19 • Mode Status, Address 1 (0x01)
Bit Name
Access Description
RO 1: 100BASE-T4 capable.
Default
15 100BASE-T4 capability
0
1
1
1
1
0
0
1
14 100BASE-TX FDX capability RO
13 100BASE-TX HDX capability RO
1: 100BASE-TX FDX capable.
1: 100BASE-TX HDX capable.
1: 10BASE-T FDX capable.
1: 10BASE-T HDX capable.
1: 100BASE-T2 FDX capable.
1: 100BASE-T2 HDX capable.
12 10BASE-T FDX capability
11 10BASE-T HDX capability
RO
RO
10 100BASE-T2 FDX capability RO
9
8
100BASE-T2 HDX capability RO
Extended status enable
RO
1: Extended status information present in
register 15.
7
Unidirectional ability
RO
1: PHY able to transmit from media
independent interface regardless of
whether the PHY has determined that a
valid link has been established.
0: PHY able to transmit from media
independent interface only when the PHY
has determined that a valid link has been
established.
1
Note: This bit is only applicable to
100BASE-FX and
1000BASE-X fiber media
modes.
6
Preamble suppression
capability
RO
1: MF preamble can be suppressed.
0: MF required.
1
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
47
Registers
Table 19 • Mode Status, Address 1 (0x01) (continued)
Bit Name Access Description
Default
5
4
Autonegotiation complete
RO
RO
1: Autonegotiation complete.
0
0
Remote fault
Latches high.
1: Far-end fault detected.
3
2
Autonegotiation capability
Link status
RO
RO
1: Autonegotiation capable.
1
0
Latches low.
1: Link is up.
1
0
Jabber detect
RO
RO
Latches high.
1: Jabber condition detected.
0
1
Extended capability
1: Extended register capable.
4.2.3
Device Identification
All 16 bits in both register 2 and register 3 in the VSC8504-01 are used to provide information associated
with aspects of the device identification. The following tables list the expected readouts.
Table 20 • Identifier 1, Address 2 (0x02)
Bit Name
Access Description
RO OUI most significant bits (3:18)
Default
15:0 Organizationally unique identifier
(OUI)
0×0007
Table 21 • Identifier 2, Address 3 (0x03)
Bit
Name
Access Description
Default
15:10 OUI
RO
RO
OUI least significant bits (19:24)
000001
001100
9:4
3:0
Microsemi model
number
VSC8504-01 (0xC)
Device revision number RO
Revision D
0010
4.2.4
Autonegotiation Advertisement
The bits in address 4 in the main registers space control the VSC8504-01 ability to notify other devices of
the status of its autonegotiation feature. The following table shows the available settings and readouts.
Table 22 • Device Autonegotiation Advertisement, Address 4 (0x04)
Bit Name
Access Description
Default
15 Next page transmission request R/W
1: Request enabled
0
0
0
0
0
0
0
1
1
1
14 Reserved
RO
Reserved
13 Transmit remote fault
12 Reserved
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1: Enabled
Reserved
11 Advertise asymmetric pause
10 Advertise symmetric pause
1: Advertises asymmetric pause
1: Advertises symmetric pause
1: Advertises 100BASE-T4
1: Advertise 100BASE-TX FDX
1: Advertises 100BASE-TX HDX
1: Advertises 10BASE-T FDX
9
8
7
6
Advertise100BASE-T4
Advertise100BASE-TX FDX
Advertise100BASE-TX HDX
Advertise10BASE-T FDX
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
48
Registers
Table 22 • Device Autonegotiation Advertisement, Address 4 (0x04) (continued)
Bit Name
Access Description
Default
1
5
Advertise10BASE-T HDX
R/W
R/W
1: Advertises 10BASE-T HDX
4:0 Advertise selector
00001
4.2.5
Link Partner Autonegotiation Capability
The bits in main register 5 can be used to determine if the Cat5 link partner (LP) used with the
VSC8504-01 is compatible with the autonegotiation functionality.
Table 23 • Autonegotiation Link Partner Ability, Address 5 (0x05)
Bit Name
Access Description
Default
15 LP next page transmission request RO
1: Requested
0
14 LP acknowledge
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
1: Acknowledge
0
13 LP remote fault
1: Remote fault
0
12 Reserved
Reserved
0
11 LP advertise asymmetric pause
10 LP advertise symmetric pause
1: Capable of asymmetric pause
1: Capable of symmetric pause
1: Capable of 100BASE-T4
1: Capable of 100BASE-TX FDX
1: Capable of 100BASE-TX HDX
1: Capable of 10BASE-T FDX
1: Capable of 10BASE-T HDX
0
0
9
8
7
6
5
LP advertise 100BASE-T4
0
LP advertise 100BASE-TX FDX
LP advertise 100BASE-TX HDX
LP advertise 10BASE-T FDX
LP advertise 10BASE-T HDX
0
0
0
0
4:0 LP advertise selector
00000
4.2.6
Autonegotiation Expansion
The bits in main register 6 work together with those in register 5 to indicate the status of the LP
autonegotiation functioning. The following table shows the available settings and readouts.
Table 24 • Autonegotiation Expansion, Address 6 (0x06)
Bit
Name
Access Description
Default
All zeros
0
15:5 Reserved
RO
RO
Reserved.
4
Parallel detection fault
LP next page capable
This bit latches high.
1: Parallel detection fault.
3
2
1
RO
1: LP is next page capable.
0
1
0
Local PHY next page capable RO
Page received RO
1: Local PHY is next page capable.
This bit latches low.
1: New page is received.
0
LP is autonegotiation capable RO
1: LP is capable of autonegotiation.
0
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
49
Registers
4.2.7
Transmit Autonegotiation Next Page
The settings in register 7 in the main registers space provide information about the number of pages in
an autonegotiation sequence. The following table shows the settings available.
Table 25 • Autonegotiation Next Page Transmit, Address 7 (0x07)
Bit
15
14
13
Name
Access Description
Default
Next page
Reserved
Message page
R/W
RO
1: More pages follow
0
0
1
Reserved
R/W
1: Message page
0: Unformatted page
12
11
Acknowledge 2
Toggle
R/W
RO
1: Complies with request
0: Cannot comply with request
0
1: Previous transmitted LCW = 0 0: 0
Previous transmitted LCW = 1
10:0 Message/unformatted code R/W
00000000001
4.2.8
Autonegotiation Link Partner Next Page Receive
The bits in register 8 of the main register space work together with register 7 to determine certain aspects
of the LP autonegotiation. The following table shows the possible readouts.
Table 26 • Autonegotiation LP Next Page Receive, Address 8 (0x08)
Bit
15
14
13
Name
Access Description
Default
LP next page
Acknowledge
LP message page
RO
RO
RO
1: More pages follow
0
0
0
1: LP acknowledge
1: Message page
0: Unformatted page
12
11
LP acknowledge 2
LP toggle
RO
RO
1: LP complies with request
0
0
1: Previous transmitted LCW = 0
0: Previous transmitted LCW = 1
10:0 LP message/unformatted code RO
All zeros
4.2.9
1000BASE-T Control
The VSC8504-01's 1000BASE-T functionality is controlled by the bits in register 9 of the main register
space. The following table shows the settings and readouts available.
Table 27 • 1000BASE-T Control, Address 9 (0x09)
Bit
Name
Access Description
Default
15:13 Transmitter test mode R/W
000: Normal
000
001: Mode 1: Transmit waveform test
010: Mode 2: Transmit jitter test as master
011: Mode 3: Transmit jitter test as slave
100: Mode 4: Transmitter distortion test
101–111: Reserved
12
Master/slave manual
configuration
R/W
1: Master/slave manual configuration enabled 0
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
50
Registers
Table 27 • 1000BASE-T Control, Address 9 (0x09) (continued)
Bit
Name
Access Description
Default
11
Master/slave value
R/W
This register is only valid when bit 9.12 is set
0
to 1.
1: Configure PHY as master during
negotiation
0: Configure PHY as slave during negotiation
10
9
Port type
R/W
R/W
R/W
R/W
1: Multi-port device
0: Single-port device
1
1000BASE-T FDX
capability
1: PHY is 1000BASE-T FDX capable
1: PHY is 1000BASE-T HDX capable
Reserved
1
8
1000BASE-T HDX
capability
1
7:0
Reserved
0x00
Note: Transmitter test mode (bits 15:13) operates in the manner described in IEEE 802.3 section 40.6.1.1.2.
When using any of the transmitter test modes, the automatic media sense feature must be disabled. For
more information, see Extended PHY Control Set 1, page 56.
4.2.10 1000BASE-T Status
The bits in register 10 of the main register space can be read to obtain the status of the 1000BASE-T
communications enabled in the device. The following table shows the readouts.
Table 28 • 1000BASE-T Status, Address 10 (0x0A)
Bit Name
Access Description
Default
15 Master/slave
RO
This bit latches high.
0
configuration fault
1: Master/slave configuration fault detected
0: No master/slave configuration fault detected
14 Master/slave
configuration resolution
RO
RO
1: Local PHY configuration resolved to master 1
0: Local PHY configuration resolved to slave
13 Local receiver status
1: Local receiver is operating normally
1: Remote receiver OK
0
0
0
12 Remote receiver status RO
11 LP 1000BASE-T FDX
capability
RO
1: LP 1000BASE-T FDX capable
10 LP 1000BASE-T HDX
capability
RO
1: LP 1000BASE-T HDX capable
0
9:8 Reserved
RO
RO
Reserved
00
7:0 Idle error count
Self-clearing register
0x00
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
51
Registers
4.2.11 MMD Access Control Register
The bits in register 13 of the main register space are a window to the EEE registers as defined in
IEEE 802.3az-2010 Clause 45.
Table 29 • MMD EEE Access, Address 13 (0x0D)
Bit
Name
Access Description
15:14 Function R/W
00: Address
01: Data, no post increment
10: Data, post increment for read and write
11: Data, post increment for write only
13:5
4:0
Reserved R/W
DVAD R/W
Reserved
Device address as defined in IEEE 802.3az-2010 table
45–1
4.2.12 MMD Address or Data Register
The bits in register 14 of the main register space are a window to the EEE registers as defined in
IEEE 802.3az-2010 Clause 45.
Table 30 • MMD Address or Data Register, Address 14 (0x0E)
Bit
Name
Access Description
15:0 Register Address/Data R/W
When register 13.15:14 = 2'b00, address of register of
the device that is specified by 13.4:0. Otherwise, the
data to be written to or read from the register.
4.2.13 1000BASE-T Status Extension 1
Register 15 provides additional information about the operation of the device 1000BASE-T
communications. The following table shows the readouts available.
Table 31 • 1000BASE-T Status Extension 1, Address 15 (0x0F)
Bit
15
14
13
12
Name
Access Description
Default
1000BASE-X FDX capability RO
1000BASE-X HDX capability RO
1000BASE-T FDX capability RO
1000BASE-T HDX capability RO
1: PHY is 1000BASE-X FDX capable 1
1: PHY is 1000BASE-X HDX capable 1
1: PHY is 1000BASE-T FDX capable 1
1: PHY is 1000BASE-T HDX capable 1
11:0 Reserved
RO
Reserved
0x000
4.2.14 100BASE-TX/FX Status Extension
Register 16 in the main registers page space of the VSC8504-01 provides additional information about
the status of the device's 100BASE-TX/100BASE-FX operation.
Table 32 • 100BASE-TX/FX Status Extension, Address 16 (0x10)
Bit Name
Access Description
Default
15 100BASE-TX/FX Descrambler
14 100BASE-TX/FX lock error
RO
RO
1: Descrambler locked
0
0
Self-clearing bit.
1: Lock error detected
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
52
Registers
Table 32 • 100BASE-TX/FX Status Extension, Address 16 (0x10) (continued)
Bit Name
Access Description
Default
13 100BASE-TX/FX disconnect
state
RO
Self-clearing bit.
1: PHY 100BASE-TX link disconnect
detected
0
12 100BASE-TX/FX current link
status
RO
RO
1: PHY 100BASE-TX link active
0
0
0
0
11 100BASE-TX/FX receive error
Self-clearing bit.
1: Receive error detected
10 100BASE-TX/FX transmit error RO
Self-clearing bit.
1: Transmit error detected
9
100BASE-TX/FX SSD error
100BASE-TX/FX ESD error
RO
RO
RO
Self-clearing bit.
1: Start-of-stream delimiter error
detected
8
Self-clearing bit.
1: End-of-stream delimiter error
detected
0
7:0 Reserved
Reserved
4.2.15 1000BASE-T Status Extension 2
The second status extension register is at address 17 in the device main registers space. It provides
information about another set of parameters associated with 1000BASE-T communications. For
information about the first status extension register, see Table 31, page 52.
Table 33 • 1000BASE-T Status Extension 2, Address 17 (0x11)
Bit Name
Access Description
Default
15 1000BASE-T descrambler
14 1000BASE-T lock error
RO
RO
1: Descrambler locked.
0
0
Self-clearing bit.
1: Lock error detected
13 1000BASE-T disconnect state RO
Self-clearing bit.
0
1: PHY 1000BASE-T link disconnect
detected
12 1000BASE-T current link
status
RO
RO
RO
RO
RO
1: PHY 1000BASE-T link active
0
0
0
0
0
0
0
0
11 1000BASE-T receive error
Self-clearing bit.
1: Receive error detected
10 1000BASE-T transmit error
Self-clearing bit.
1: Transmit error detected
9
8
7
6
5
1000BASE-T SSD error
1000BASE-T ESD error
Self-clearing bit.
1: Start-of-stream delimiter error detected
Self-clearing bit.
1: End-of-stream delimiter error detected
1000BASE-T carrier extension RO
error
Self-clearing bit.
1: Carrier extension error detected
Non-compliant BCM5400
detected
RO
1: Non-compliant BCM5400 link partner
detected
MDI crossover error
RO
1: MDI crossover error was detected
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
53
Registers
Table 33 • 1000BASE-T Status Extension 2, Address 17 (0x11) (continued)
Bit Name
Access Description
RO Reserved
Default
4:0 Reserved
4.2.16 Bypass Control
The bits in this register control aspects of functionality in effect when the device is disabled for the
purpose of traffic bypass. The following table shows the settings available.
Table 34 • Bypass Control, Address 18 (0x12)
Bit Name
Access Description
Default
15 Transmit disable
14 4B5B encoder/decoder
13 Scrambler
R/W
R/W
R/W
R/W
R/W
R/W
R/W
RO
1: PHY transmitter disabled
0
0
0
0
0
0
0
1: Bypass 4B/5B encoder/decoder
1: Bypass scrambler
12 Descrambler
11 PCS receive
10 PCS transmit
1: Bypass descrambler
1: Bypass PCS receiver
1: Bypass PCS transmit
1: Bypass Link Fail Inhibit (LFI) timer
Reserved
9
8
7
LFI timer
Reserved
HP Auto-MDIX at forced
10/100
R/W
Sticky bit.
1
0
0
0
1
1: Disable HP Auto-MDIX at forced 10/100
speeds
6
5
4
3
Non-compliant BCM5400
detect disable
R/W
Sticky bit.
1: Disable non-compliant BCM5400
detection
Disable pair swap correction R/W
(HP Auto-MDIX when
autonegotiation enabled)
Sticky bit.
1: Disable the automatic pair swap
correction
Disable polarity correction
Parallel detect control
Pulse shaping filter
R/W
R/W
Sticky bit.
1: Disable polarity inversion correction on
each subchannel
Sticky bit.
1: Do not ignore advertised ability
0: Ignore advertised ability
2
1
R/W
R/W
1: Disable pulse shaping filter
0
0
Disable automatic
1000BASE-T next page
exchange
Sticky bit.
1: Disable automatic 1000BASE T next
page exchanges
0
Reserved
RO
Reserved
Note: If bit 18.1 is set to 1 in this register, automatic exchange of next pages is disabled, and control is returned
to the user through the SMI after the base page is exchanged. The user then must send the correct
sequence of next pages to the link partner, determine the common capabilities, and force the device into
the correct configuration following the successful exchange of pages.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
54
Registers
4.2.17 Error Counter 1
The bits in register 19 provide an error counter. The following table shows the settings available.
Table 35 • Extended Control and Status, Address 19 (0x13)
Bit
15:8 Reserved
7:0 100/1000 receive
error counter
Name
Access Description
Default
RO
RO
Reserved.
8-bit counter that saturates when it reaches
255. These bits are self-clearing when read.
0x00
4.2.18 Error Counter 2
The bits in register 20 provide an error counter. The following table shows the settings available.
Table 36 • Extended Control and Status, Address 20 (0x14)
Bit
Name
Access Description
Default
15:8 Reserved
RO
Reserved.
7:0
100/1000 false carrier RO
counter
8-bit counter that saturates when it reaches
255. These bits are self-clearing when read.
0x00
4.2.19 Error Counter 3
The bits in register 21 provide an error counter. The following table shows the settings available.
Table 37 • Extended Control and Status, Address 21 (0x15)
Bit
15:8 Reserved
7:0 Copper media link
disconnect counter
Name
Access Description
Default
RO
RO
Reserved.
8-bit counter that saturates when it reaches
255. These bits are self-clearing when read.
0x00
4.2.20 Extended Control and Status
The bits in register 22 provide additional device control and readouts. The following table shows the
settings available.
Table 38 • Extended Control and Status, Address 22 (0x16)
Bit
Name
Access Description
Default
15
Force 10BASE-T link high R/W
Sticky bit.
0
1: Bypass link integrity test
0: Enable link integrity test
14
13
12
Jabber detect disable
Disable 10BASE-T echo
Disable SQE mode
R/W
R/W
R/W
Sticky bit.
1: Disable jabber detect
0
1
1
Sticky bit.
1: Disable 10BASE-T echo
Sticky bit.
1: Disable SQE mode
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
55
Registers
Table 38 • Extended Control and Status, Address 22 (0x16) (continued)
Bit
Name
Access Description
Default
11:10 10BASE-T squelch control R/W
Sticky bit.
00
00: Normal squelch
01: Low squelch
10: High squelch
11: Reserved
9
8
7
Sticky reset enable
EOF Error
R/W
RO
Super-sticky bit.
1: Enabled
1
0
0
0
This bit is self-clearing.
1: EOF error detected
10BASE-T disconnect state RO
This bit is self-clearing.
1: 10BASE-T link disconnect detected
6
10BASE-T link status
Reserved
RO
RO
R/W
1: 10BASE-T link active
Reserved
5:1
0
SMI broadcast write
Sticky bit.
0
1: Enabled
The following information applies to the extended control and status bits:
•
When bit 22.15 is set, the link integrity state machine is bypassed and the PHY is forced into a link
pass status.
•
When bits 22.11:10 are set to 00, the squelch threshold levels are based on the IEEE standard for
10BASE-T. When set to 01, the squelch level is decreased, which can improve the bit error rate
performance on long loops. When set to 10, the squelch level is increased and can improve the bit
error rate in high-noise environments.
•
•
When bit 22.9 is set, all sticky register bits retain their values during a software reset. Clearing this
bit causes all sticky register bits to change to their default values upon software reset. Super-sticky
bits retain their values upon software reset regardless of the setting of bit 22.9.
When bit 22.0 is set, if a write to any PHY register (registers 0–31, including extended registers), the
same write is broadcast to all PHYs. For example, if bit 22.0 is set to 1 and a write to PHY0 is
executed (register 0 is set to 0x1040), all PHYs' register 0s are set to 0x1040.Disabling this bit
restores normal PHY write operation. Reads are still possible when this bit is set, but the value that
is read corresponds only to the particular PHY being addressed.
4.2.21 Extended PHY Control Set 1
The following table shows the settings available.
Table 39 • Extended PHY Control 1, Address 23 (0x17)
Bit
Name
Access Description
Default
15:13 Reserved
R/W
MAC interface mode R/W
Reserved
0
0
12
11
Super-sticky bit.
0: SGMII
1: 1000BASE-X.
Note: Register 19G.15:14 must be = 00
for this selection to be valid.
AMS preference
R/W
Super-sticky bit.
0
1: Cat5 copper preferred.
0: SerDes fiber/SFP preferred.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
56
Registers
Table 39 • Extended PHY Control 1, Address 23 (0x17) (continued)
Bit
Name
Access Description
R/W Super-sticky bits.
Default
10:8
Media operating
mode
000
000: Cat5 copper only.
001: SerDes fiber/SFP protocol transfer mode
only.
010: 1000BASE-X fiber/SFP media only with
autonegotiation performed by the PHY.
011: 100BASE-FX fiber/SFP on the fiber media
pins only.
101: Automatic media sense (AMS) with Cat5
media or SerDes fiber/SFP protocol transfer
mode.
110: AMS with Cat5 media or 1000BASE-X
fiber/SFP media with autonegotiation performed
by PHY.
111: AMS with Cat5 media or 100BASE-FX
fiber/SFP media.
100: AMS.
7:6
Force AMS override R/W
00: Normal AMS selection
00
0
01: Force AMS to select SerDes media only
10: Force AMS to select copper media only
11: Reserved
5:4
3
Reserved
RO
Reserved.
Far-end loopback
mode
R/W
1: Enabled.
2:0
Reserved
RO
Reserved.
Note: After configuring bits 13:8 of the extended PHY control register set 1, a software reset (register 0, bit 15)
must be written to change the device operating mode. On read, these bits only indicate the actual
operating mode and not the pending operating mode setting before a software reset has taken place.
4.2.22 Extended PHY Control Set 2
The second set of extended controls is located in register 24 in the main register space for the device.
The following table shows the settings and readouts available.
Table 40 • Extended PHY Control 2, Address 24 (0x18)
Bit
Name
Access Description
Default
15:13 100BASE-TX edge
rate control
R/W
Sticky bit.
001
011: +5 edge rate (slowest)
010: +4 edge rate
001: +3 edge rate
000: +2 edge rate
111: +1 edge rate
110: Default edge rate
101: –1 edge rate
100: –2 edge rate (fastest)
12
PICMG 2.16 reduced R/W
power mode
Sticky bit.
1: Enabled
0
11:6
Reserved
RO
Reserved
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
57
Registers
Table 40 • Extended PHY Control 2, Address 24 (0x18) (continued)
Bit
Name
Access Description
Default
5:4
Jumbo packet mode R/W
Sticky bit.
00
00: Normal IEEE 1.5 kB packet length
01: 9 kB jumbo packet length (12 kB with
60 ppm or better reference clock)
10: 12 kB jumbo packet length (16 kB with
70 ppm or better reference clock)
11: Reserved
3:1
0
Reserved
RO
Reserved
1000BASE-T
R/W
1: Enabled
0
connector loopback
Note: When bits 5:4 are set to jumbo packet mode, the default maximum packet values are based on 100 ppm
driven reference clock to the device. Controlling the ppm offset between the MAC and the PHY as
specified in the bit description results in a higher jumbo packet length.
4.2.23 Interrupt Mask
These bits control the device interrupt mask. The following table shows the settings available.
Table 41 • Interrupt Mask, Address 25 (0x19)
Bit Name
Access Description
Default
15
14
13
12
11
10
9
MDINT interrupt status enable
R/W
R/W
R/W
R/W
R/W
R/W
Sticky bit. 1: Enabled.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Speed state change mask
Link state change mask
Sticky bit. 1: Enabled.
Sticky bit. 1: Enabled.
Sticky bit. 1: Enabled.
Sticky bit. 1: Enabled.
Sticky bit. 1: Enabled.
Sticky bit. 1: Enabled.
Sticky bit. 1: Enabled.
Sticky bit. 1: Enabled.
FDX state change mask
Autonegotiation error mask
Autonegotiation complete mask
Inline powered device (PoE) detect mask R/W
8
Symbol error interrupt mask
Fast link failure interrupt mask
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
7
6:5 Reserved
4
3
2
1
0
AMS media changed mask(1)
Sticky bit. 1: Enabled.
Sticky bit. 1: Enabled.
Sticky bit. 1: Enabled.
Sticky bit. 1: Enabled.
Sticky bit. 1: Enabled.
False carrier interrupt mask
Link speed downshift detect mask
Master/Slave resolution error mask
RX_ER interrupt mask
1. If hardware interrupts are not used, the mask can still be set and the status polled for changes.
Note: When bit 25.15 is set, the MDINT pin is enabled. When enabled, the state of this pin reflects the state of
bit 26.15. Clearing this bit only inhibits the MDINT pin from being asserted. Also, before enabling this bit,
read register 26 to clear any previously inactive interrupts pending that will cause bit 25.15 to be set.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
58
Registers
4.2.24 Interrupt Status
The status of interrupts already written to the device is available for reading from register 26 in the main
registers space. The following table shows the expected readouts.
Table 42 • Interrupt Status, Address 26 (0x1A)
Bit Name
Access Description
Default
15
14
13
12
11
10
9
Interrupt status
RO
RO
RO
RO
RO
Self-clearing bit. 1: Interrupt pending.
0
0
0
0
0
0
0
Speed state change status
Link state change status
FDX state change status
Autonegotiation error status
Self-clearing bit. 1: Interrupt pending.
Self-clearing bit. 1: Interrupt pending.
Self-clearing bit. 1: Interrupt pending.
Self-clearing bit. 1: Interrupt pending.
Self-clearing bit. 1: Interrupt pending.
Self-clearing bit. 1: Interrupt pending.
Autonegotiation complete status RO
Inline powered device detect
status
RO
8
7
Symbol error status
RO
RO
RO
RO
RO
RO
Self-clearing bit. 1: Interrupt pending.
Self-clearing bit. 1: Interrupt pending.
0
0
0
0
0
0
Fast link failure detect status
6:5 Reserved
4
3
2
AMS media changed mask(1)
Self-clearing bit. 1: Interrupt pending.
Self-clearing bit. 1: Interrupt pending.
Self-clearing bit. 1: Interrupt pending.
False carrier interrupt status
Link speed downshift detect
status
1
0
Master/Slave resolution error
status
RO
RO
Self-clearing bit. 1: Interrupt pending.
Self-clearing bit. 1: Interrupt pending.
0
0
RX_ER interrupt status
1. If hardware interrupts are not used, the mask can still be set and the status polled for changes.
The following information applies to the interrupt status bits:
•
All set bits in this register are cleared after being read (self-clearing). If bit 26.15 is set, the cause of
the interrupt can be read by reading bits 26.14:0.
•
•
•
For bits 26.14 and 26.12, bit 0.12 must be set for this interrupt to assert.
For bit 26.2, bits 4.8:5 must be set for this interrupt to assert.
For bit 26.0, this interrupt will not occur when RX_ER is used for carrier-extension decoding of a link
partner's data transmission.
4.2.25 Device Auxiliary Control and Status
Register 28 provides control and status information for several device functions not controlled or
monitored by other device registers. The following table shows the settings available and the expected
readouts.
Table 43 • Auxiliary Control and Status, Address 28 (0x1C)
Bit Name
Access Description
Default
15 Autonegotiation complete
RO
RO
RO
Duplicate of bit 1.5
0
0
0
14 Autonegotiation disabled
Inverted duplicate of bit 0.12
131 HP Auto-MDIX crossover
indication
1: HP Auto-MDIX crossover performed
internally
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
59
Registers
Table 43 • Auxiliary Control and Status, Address 28 (0x1C) (continued)
Bit Name
Access Description
Default
12 CD pair swap
11 A polarity inversion
10 B polarity inversion
RO
RO
RO
RO
RO
1: CD pairs are swapped
0
0
0
0
0
0
1: Polarity swap on pair A
1: Polarity swap on pair B
1: Polarity swap on pair C
1: Polarity swap on pair D
9
8
7
C polarity inversion
D polarity inversion
ActiPHY link status time-out R/W
control [1]
Sticky bit. Bits 7 and 2 are part of the
ActiPHY Link Status time-out control. Bit 7
is the MSB.
00: 2.3 seconds
01: 3.3 seconds
10: 4.3 seconds
11: 5.3 seconds
6
5
ActiPHY mode enable
FDX status
R/W
RO
RO
Sticky bit.
1: Enabled
0
1: Full-duplex
0: Half-duplex
00
0
4:3 Speed status
00: Speed is 10BASE-T
01: Speed is 100BASE-TX or 100BASE-FX
10: Speed is 1000BASE-T or 1000BASE-X
11: Reserved
2
ActiPHY link status time-out R/W
control [0]
Sticky bit. Bits 7 and 2 are part of the
ActiPHY Link Status time-out control. Bit 7
is the MSB.
1
00: 2.3 seconds
01: 3.3 seconds
10: 4.3 seconds
11: 5.3 seconds
1:0 Media mode status
RO
00: No media selected
01: Copper media selected
10: SerDes (Fiber) media selected
11: Reserved
00
1. In 1000BT mode, if Force MDI crossover is performed while link is up, the 1000BT link must be re-negotiated
in order for this bit to reflect the actual Auto-MDIX setting.
4.2.26 LED Mode Select
The device LED outputs are controlled using the bits in register 29 of the main register space. The
following table shows the information needed to access the functionality of each of the outputs. For more
information about LED modes, see Table 7, page 25. For information about enabling the extended LED
mode bits in Register 19E1 bits 13 to 12, see Table 8, page 27.
Table 44 • LED Mode Select, Address 29 (0x1D)
Bit
Name
Access Description
Default
15:12 LED3 mode select R/W
Sticky bit. Select from LED modes 0–15. 1000
11:8
7:4
LED2 mode select R/W
LED1 mode select R/W
LED0 mode select R/W
Sticky bit. Select from LED modes 0–15. 0000
Sticky bit. Select from LED modes 0–15. 0010
Sticky bit. Select from LED modes 0–15. 0001
3:0
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
60
Registers
4.2.27 LED Behavior
The bits in register 30 control and enable you to read the status of the pulse or blink rate of the device
LEDs. The following table shows the settings you can write to the register or read from the register.
Table 45 • LED Behavior, Address 30 (0x1E)
Bit
Name
Access Description
Default
15
Copper and fiber
R/W
Sticky bit
0
LED combine disable
0: Combine enabled (Copper/Fiber on
link/linkXXXX/activity LED)
1: Disable combination (link/linkXXXX/activity
LED; indicates copper only)
14
Activity output select R/W
Sticky bit
0
1: Activity LED becomes TX_Activity and fiber
activity LED becomes RX_Activity
0: TX and RX activity both displayed on activity
LEDs
13
12
Reserved
RO
Reserved
LED pulsing enable R/W
Sticky bit
0
0: Normal operation
1: LEDs pulse with a 5 kHz, programmable duty
cycle when active
11:10 LED blink/pulse-
stretch rate
R/W
Sticky bit
01
00: 2.5 Hz blink rate/400 ms pulse-stretch
01: 5 Hz blink rate/200 ms pulse-stretch
10: 10 Hz blink rate/100 ms pulse-stretch
11: 20 Hz blink rate/50 ms pulse-stretch
The blink rate selection for PHY0 globally sets
the rate used for all LED pins on all PHY ports
9
8
Reserved
RO
Reserved
LED3 pulse-
stretch/blink select
R/W
Sticky bit
1: Pulse-stretch
0: Blink
0
0
0
0
7
6
5
LED2 pulse-
stretch/blink select
R/W
R/W
R/W
Sticky bit
1: Pulse-stretch
0: Blink
LED1 pulse-
stretch/blink select
Sticky bit
1: Pulse-stretch
0: Blink
LED0 pulse-
Sticky bit
stretch/blink select
1: Pulse-stretch
0: Blink
4
3
Reserved
RO
Reserved
LED3 combine
feature disable
R/W
Sticky bit
0: Combine enabled (link/activity,
duplex/collision)
0
0
1: Disable combination (link only, duplex only)
2
LED2 combine
feature disable
R/W
Sticky bit
0: Combine enabled (link/activity,
duplex/collision)
1: Disable combination (link only, duplex only)
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
61
Registers
Table 45 • LED Behavior, Address 30 (0x1E) (continued)
Bit
Name
Access Description
Default
1
LED1 combine
feature disable
R/W
Sticky bit
0: Combine enabled (link/activity,
duplex/collision)
0
1: Disable combination (link only, duplex only)
0
LED0 combine
feature disable
R/W
Sticky bit
0: Combine enabled (link/activity,
duplex/collision)
0
1: Disable combination (link only, duplex only)
Note: Bits 30.11:10 are active only in port 0 and affect the behavior of LEDs for all the ports.
4.2.28 Extended Page Access
To provide functionality beyond the IEEE 802.3-specified registers and main device registers, the
VSC8504-01 includes an extended set of registers that provide an additional 15 register spaces.
The register at address 31 controls the access to the extended registers for the VSC8504-01. Accessing
the GPIO page register space is similar to accessing the extended page registers. The following table
shows the settings available.
Table 46 • Extended/GPIO Register Page Access, Address 31 (0x1F)
Bit
Name
Access Description
Default
15:0 Extended/GPIO page R/W
register access
0x0000: Register 16–30 accesses main register 0x0000
space. Writing 0x0000 to register 31 restores the
main register access.
0x0001: Registers 16–30 access extended
register space 1
0x0002: Registers 16–30 access extended
register space 2
0x0003: Registers 16–30 access extended
register space 3
0x0010: Registers 0–30 access GPIO register
space
4.3
Extended Page 1 Registers
To access the extended page 1 registers (16E1–30E1), enable extended register access by writing
0x0001 to register 31. Writing 0x0000 to register 31 restores the main register access.
When extended page 1 register access is enabled, reads and writes to registers 16–30 affect the
extended registers 16E1–30E1 instead of those same registers in the IEEE-specified register space.
Registers 0–15 are not affected by the state of the extended page register access.
Table 47 • Extended Registers Page 1 Space
Address
16E1
Name
SerDes Media Control
Reserved
17E1
18E1
Cu Media CRC good counter
Extended mode and SIGDET control
Extended PHY control 3 (ActiPHY)
19E1
20E1
21E1–22E1 Reserved
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
62
Registers
Table 47 • Extended Registers Page 1 Space (continued)
Address
23E1
Name
Extended PHY control 4 (PoE and CRC error counter)
24E1
VeriPHY 1
VeriPHY 2
VeriPHY 3
25E1
26E1
27E1–28E1 Reserved
29E1
30E1
Ethernet packet generator (EPG) 1
EPG 2
4.3.1
SerDes Media Control
Register 16E1 controls some functions of the SerDes media interface on ports 0–3. These settings are
only valid for those ports. The following table shows the setting available in this register.
Table 48 • SerDes Media Control, Address 16E1 (0x10)
Bit Name Access Description
Default
15:14 Transmit remote fault
R/W
RO
RO
Remote fault indication sent to link
partner (LP)
00
13:12 Link partner (LP) remote
fault
Remote fault bits sent by LP during
autonegotiation
00
1
11:10 Reserved
Reserved
9
Allow 1000BASE-X link-up R/W
Sticky bit.
1: Allow 1000BASE-X fiber media link-up
capability
0: Suppress 1000BASE-X fiber media
link-up capability
8
Allow 100BASE-FX link-up R/W
Sticky bit.
1
0
1: Allow 100BASE-FX fiber media link-up
capability
0: Suppress 100BASE-FX fiber media
link-up capability
7
6
Reserved
RO
RO
Reserved
Far end fault detected in
100BASE-FX
Self-clearing bit.
1: Far end fault in 100BASE-FX detected
5:0
Reserved
RO
Reserved
4.3.2
Cu Media CRC Good Counter
Register 18E1 makes it possible to read the contents of the CRC good counter for packets that are
received on the Cu media interface; the number of CRC routines that have executed successfully. The
following table shows the expected readouts.
Table 49 • Cu Media CRC Good Counter, Address 18E1 (0x12)
Bit
Name
Access Description
Default
15
Packet since last read RO
Self-clearing bit.
0
1: Packet received since last read.
14
Reserved
RO
Reserved.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
63
Registers
Table 49 • Cu Media CRC Good Counter, Address 18E1 (0x12) (continued)
Bit
Name
Access Description
RO Self-clearing bit. Counter containing the
Default
13:0 Cu Media CRC good
counter contents
0x000
number of packets with valid CRCs modulo
10,000; this counter does not saturate and
will roll over to zero on the next good packet
received after 9,999.
4.3.3
Extended Mode Control
Register 19E1 controls the extended LED and other chip modes. The following table shows the settings
available.
Table 50 • Extended Mode Control, Address 19E1 (0x13)
Bit
15
14
13
12
11
Name
Access Description
Default
LED3 Extended Mode
LED2 Extended Mode
LED1 Extended Mode
LED0 Extended Mode
R/W
R/W
R/W
R/W
1: See Extended LED Modes, page 27
0
0
0
0
0
1: See Extended LED Modes, page 27
1: See Extended LED Modes, page 27
1: See Extended LED Modes, page 27
LED Reset Blink Suppress R/W
1: Blink LEDs after COMA_MODE is
de-asserted
0: Suppress LED blink after COMA_MODE
is de-asserted
10:5 Reserved
RO
Reserved
0
0
4
Fast link failure
R/W
Enable fast link failure pin. This must be
done from PHY0 only.
1: Enabled
0: Disabled (GPIO9 pin becomes general
purpose I/O)
3:2
Force MDI crossover
Reserved
R/W
RO
00: Normal HP Auto-MDIX operation
01: Reserved
10: Copper media forced to MDI
11: Copper media forced MDI-X
00
0
1
0
Reserved
GPIO[3:0]/SIGDET[3:0] pin R/W
polarity
1: Active low
0: Active high
4.3.4
ActiPHY Control
Register 20E1 controls the device ActiPHY sleep timer, its wake-up timer, and its link speed downshifting
feature. The following table shows the settings available.
Table 51 • Extended PHY Control 3, Address 20E1 (0x14)
Bit
Name
Access Description
1: Disable carrier extension in 1000BASE-T 1
copper links
Default
15
Disable carrier extension R/W
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
64
Registers
Table 51 • Extended PHY Control 3, Address 20E1 (0x14) (continued)
Bit Name Access Description
Default
14:13 ActiPHY sleep timer
R/W
Sticky bit.
01
00: 1 second
01: 2 seconds
10: 3 seconds
11: 4 seconds
12:11 ActiPHY wake-up timer
R/W
Sticky bit.
00
00: 160 ms
01: 400 ms
10: 800 ms
11: 2 seconds
10
9
Reserved
RO
Reserved
PHY address reversal
R/W
Reverse PHY address
0
Enabling causes physical PHY 0 to have
address of 3, PHY 1 address of 2, PHY 2
address of 1, and PHY 3 address of 0.
Changing this bit to 1 should initially be
done from PHY 0 and changing to 0 from
PHY3
1: Enabled
0: Disabled
8
Reserved
RO
RO
Valid only on PHY0
7:6
Media mode status
00: No media selected
01: Copper media selected
10: SerDes media selected
11: Reserved
00
0
5
Enable 10BASE-T no
preamble mode
R/W
R/W
Sticky bit.
1: 10BASE-T will assert RX_DV indication
when data is presented to the receiver even
without a preamble preceding it
4
Enable link speed
Sticky bit.
0
autodownshift feature
1: Enable auto link speed downshift from
1000BASE-T
3:2
Link speed auto downshift R/W
control
Sticky bits.
00: Downshift after 2 failed 1000BASE-T
autonegotiation attempts
01
01: Downshift after 3 failed 1000BASE-T
autonegotiation attempts
10: Downshift after 4 failed 1000BASE-T
autonegotiation attempts
11: Downshift after 5 failed 1000BASE-T
autonegotiation attempts
1
0
Link speed auto downshift RO
status
0: No downshift
1: Downshift is required or has occurred
0
Reserved
RO
Reserved
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
65
Registers
4.3.5
PoE and Miscellaneous Functionality
The register at address 23E1 controls various aspects of inline powering and the CRC error counter in
the VSC8504-01.
Table 52 • Extended PHY Control 4, Address 23E1 (0x17)
Bit
Name
Access Description
RO PHY address; latched on reset
Default
15:11 PHY address
10
Inline powered device R/W
detection
Sticky bit.
1: Enabled
0
9:8
Inline powered device RO
detection status
Only valid when bit 10 is set.
00: Searching for devices
01: Device found; requires inline power
10: Device found; does not require inline
power
00
11: Reserved
7:0
Cu Media CRC error
counter
RO
Self-clearing bit
RC error counter for packets received on the Cu media interface. The value saturates at 0xFF and
subsequently clears when read and restarts count.0x00
4.3.6
VeriPHY Control 1
Register 24E1 in the extended register space provides control over the device VeriPHY diagnostics
features. There are three separate VeriPHY control registers. The following table shows the settings
available and describes the expected readouts.
Table 53 • VeriPHY Control Register 1, Address 24E1 (0x18)
Bit
Name
Access Description
Default
15
VeriPHY trigger
R/W
RO
Self-clearing bit.
0
1: Triggers the VeriPHY algorithm and clears
when VeriPHY has completed. Settings in
registers 24E–26E become valid after this bit
clears.
14
VeriPHY valid
1: VeriPHY results in registers 24E–26E are
valid.
0
13:8 Pair A (1, 2) distance RO
Loop length or distance to anomaly for pair A (1, 0x00
2).
7:6
5:0
Reserved
RO
Reserved.
Pair B (3, 6) distance RO
Loop length or distance to anomaly for pair B (3, 0x00
6).
Note: The resolution of the 6-bit length field is 3 meters.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
66
Registers
4.3.7
VeriPHY Control 2
The register at address 25E1 consists of the second of the three device registers that provide control
over VeriPHY diagnostics features. The following table shows the expected readouts.
Table 54 • VeriPHY Control Register 2, Address 25E1 (0x19)
Bit
Name
Access Description
RO Reserved
Pair C (4, 5) distance RO
Default
15:14 Reserved
13:8
Loop length or distance to anomaly for pair C 0x00
(4, 5)
7:6
5:0
Reserved
RO
Reserved
Pair D (7, 8) distance RO
Loop length or distance to anomaly for pair D 0x00
(7, 8)
Note: The resolution of the 6-bit length field is 3 meters.
4.3.8
VeriPHY Control 3
The register at address 26E1 consists of the third of the three device registers that provide control over
VeriPHY diagnostics features. Specifically, this register provides information about the termination status
(fault condition) for all four link partner pairs. The following table shows the expected readouts.
Table 55 • VeriPHY Control Register 3, Address 26E1 (0x1A)
Bit
Name
Access Description
Default
0x00
15:12 Pair A (1, 2) termination status
RO
RO
Termination fault for pair A (1, 2)
11:8
7:4
Pair B (3, 6) termination status
Termination fault for pair B (3, 4)
Termination fault for pair C (4, 5)
Termination fault for pair D (7, 8)
0x00
Pair C (4, 5) termination status RO
Pair D (7, 8) termination status RO
0x00
3:0
0x00
The following table shows the meanings for the various fault codes.
Table 56 • VeriPHY Control Register 3 Fault Codes
Code Denotes
0000 Correctly terminated pair
0001 Open pair
0010 Shorted pair
0100 Abnormal termination
1000 Cross-pair short to pair A
1001 Cross-pair short to pair B
1010 Cross-pair short to pair C
1011 Cross-pair short to pair D
1100 Abnormal cross-pair coupling with pair A
1101 Abnormal cross-pair coupling with pair B
1110 Abnormal cross-pair coupling with pair C
1111 Abnormal cross-pair coupling with pair D
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
67
Registers
4.3.9
Ethernet Packet Generator Control 1
The EPG control register provides access to and control of various aspects of the EPG testing feature.
There are two separate EPG control registers. The following table shows the settings available in the first
register.
Table 57 • EPG Control Register 1, Address 29E1 (0x1D)
Bit
15
14
13
Name
Access Description
Default
EPG enable
EPG run or stop
R/W
R/W
1: Enable EPG
1: Run EPG
0
0
0
Transmission duration R/W
1: Continuous (sends in 10,000-packet
increments)
0: Send 30,000,000 packets and stop
12:11 Packet length
R/W
00: 125 bytes
0
01: 64 bytes
10: 1518 bytes
11: 10,000 bytes (jumbo packet)
10
9:6
5:2
1
Interpacket gap
Destination address
Source address
Payload type
R/W
R/W
R/W
R/W
R/W
1: 8,192 ns
0: 96 ns
0
Lowest nibble of the 6-byte destination
address
0001
0000
0
Lowest nibble of the 6-byte destination
address
1: Randomly generated payload pattern
0: Fixed based on payload pattern
0
Bad frame check
sequence (FCS)
generation
1: Generate packets with bad FCS
0: Generate packets with good FCS
0
The following information applies to the EPG control number 1:
•
•
Do not run the EPG when the VSC8504-01 is connected to a live network.
bit 29E1.13 (continuous EPG mode control): When enabled, this mode causes the device to send
continuous packets. When disabled, the device continues to send packets only until it reaches the
next 10,000-packet increment mark. It then ceases to send packets.
•
•
•
The 6-byte destination address in bits 9:6 is assigned one of 16 addresses in the range of 0xFF FF
FF FF FF F0 through 0xFF FF FF FF FF FF.
The 6-byte source address in bits 5:2 is assigned one of 16 addresses in the range of 0xFF FF FF
FF FF F0 through 0xFF FF FF FF FF FF.
If any of bits 13:0 are changed while the EPG is running (bit 14 is set to 1), bit 14 must be cleared
and then set back to 1 for the change to take effect and to restart the EPG.
4.3.10 Ethernet Packet Generator Control 2
Register 30E1 consists of the second set of bits that provide access to and control over the various
aspects of the EPG testing feature. The following table shows the settings available.
Table 58 • EPG Control Register 2, Address 30E1 (0x1E)
Bit
Name
Access Description
Data pattern repeated in the payload of 0x00
packets generated by the EPG
Default
15:0 EPG packet payload R/W
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
68
Registers
Note: If any of bits 15:0 in this register are changed while the EPG is running (bit 14 of register 29E1 is set to
1), that bit (29E1.14) must first be cleared and then set back to 1 for the change to take effect and to
restart the EPG.
4.4
Extended Page 2 Registers
To access the extended page 2 registers (16E2–30E2), enable extended register access by writing
0x0002 to register 31. For more information, see Table 46, page 62.
When extended page 2 register access is enabled, reads and writes to registers 16–30 affect the
extended registers 16E2–30E2 instead of those same registers in the IEEE-specified register space.
Registers 0–15 are not affected by the state of the extended page register access.
Writing 0x0000 to register 31 restores the main register access.
The following table lists the addresses and register names in the extended register page 2 space. These
registers are accessible only when the device register 31 is set to 0x0002.
Table 59 • Extended Registers Page 2 Space
Address
16E2
Name
Cu PMD Transmit Control
EEE Control
17E2
18E2-29E2
30E2
Reserved
Ring Resiliency Control
4.4.1
Cu PMD Transmit Control
The register at address 16E2 consists of the bits that provide control over the amplitude settings for the
transmit side Cu PMD interface. These bits provide the ability to make small adjustments in the signal
amplitude to compensate for minor variations in the magnetics from different vendors. Extreme caution
must be exercised when changing these settings from the default values as they have a direct impact on
the signal quality. Changing these settings also affects the linearity and harmonic distortion of the
transmitted signals. For help with changing these values, contact your Microsemi representative.
Table 60 • Cu PMD Transmit Control, Address 16E2 (0x10)
Bit
Name
Access Description
Default
15:12 1000BASE-T signal R/W
amplitude trim(1)
1000BASE-T signal amplitude
1111: -1.7%
1110: -2.6%
1101: -3.5%
1100: -4.4%
1011: -5.3%
1010: -7%
0000
1001: -8.8%
1000: -10.6%
0111: 5.5%
0110: 4.6%
0101: 3.7%
0100: 2.8%
0011: 1.9%
0010: 1%
0001: 0.1%
0000: -0.8%
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
69
Registers
Table 60 • Cu PMD Transmit Control, Address 16E2 (0x10) (continued)
Bit
Name
Access Description
Default
11:8
100BASE-TX signal R/W
amplitude trim(2)
100BASE-TX signal amplitude
1111: -1.7%
1110: -2.6%
1101: -3.5%
1100: -4.4%
1011: -5.3%
1010: -7%
0010
1001: -8.8%
1000: -10.6%
0111 5.5%
0110: 4.6%
0101: 3.7%
0100: 2.8%
0011: 1.9%
0010: 1%
0001: 0.1%
0000: -0.8%
7:4
10BASE-T signal
amplitude trim(3)
R/W
10BASE-T signal amplitude
1111: -7%
1011
1110: -7.9%
1101: -8.8%
1100: -9.7%
1011: -10.6%
1010: -11.5%
1001: -12.4%
1000: -13.3%
0111: 0%
0110: -0.7%
0101: -1.6%
0100: -2.5%
0011: -3.4%
0010: -4.3%
0001: -5.2%
0000: -6.1%
3:0
10BASE-Te signal R/W
amplitude trim
10BASE-Te signal amplitude
1111: -30.45%
1110: -31.1%
1110
1101: -31.75%
1100: -32.4%
1011: -33.05%
1010: -33.7%
1001: -34.35%
1000: -35%
0111: -25.25%
0110: -25.9%
0101: -26.55%
0100: -27.2%
0011: -27.85%
0010: -28.5%
0001: -29.15%
0000: -29.8%
1. Changes to 1000BASE-T amplitude may result in unpredictable side effects.
2. Adjust 100BASE-TX to specific magnetics.
3. Amplitude is limited by VCC (2.5 V).
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
70
Registers
4.4.2
EEE Control
The register at address 17E2 consists of the bits that provide additional control over the chip behavior in
energy efficient Ethernet (IEEE 802.3az-2010) mode.
Table 61 • EEE Control, Address 17E2 (0x11)
Bit
Name
Access Description
Default
15
Enable 10BASE-Te R/W
Sticky bit.
0
Enable energy efficient (IEEE 802.3az-2010)
10BASE-Te operating mode.
14
Enable LED in fiber R/W
unidirectional mode
Sticky bit.
0
1: Enable LED functions in fiber unidirectional
mode.
13:10 Invert LED polarity
R/W
Sticky bits.
0000
Invert polarity of LED[3:0]_[3:0] signals. Default
is to drive an active low signal on the LED pins.
This also applies to enhanced serial LED mode.
For more information, see Enhanced Serial LED
Mode, page 28.
9:6
5
Reserved
RO
Reserved.
Enable 1000BASE-T R/W
force mode
Sticky bit.
0
1: Enable 1000BASE-T force mode to allow PHY
to link-up in 1000BASE-T mode without forcing
master/slave when register 0, bits 6 and 13 are
set to 2’b10.
41
Force transmit LPI
R/W
Sticky bit.
0
0
0
0
0
1: Enable the EPG to transmit LPI on the MDI,
ignore data from the MAC interface.
0: Transmit idles being received from the MAC.
3
Inhibit 100BASE-TX R/W
transmit EEE LPI
Sticky bit.
1: Disable transmission of EEE LPI on transmit
path MDI in 100BASE-TX mode when receiving
LPI from MAC.
2
Inhibit 100BASE-TX R/W
receive EEE LPI
Sticky bit.
1: Disable transmission of EEE LPI on receive
path MAC interface in 100BASE-TX mode when
receiving LPI from the MDI.
1
Inhibit 1000BASE-T R/W
transmit EEE LPI
Sticky bit.
1: Disable transmission of EEE LPI on transmit
path MDI in 1000BASE-T mode when receiving
LPI from MAC.
0
Inhibit 1000BASE-T R/W
receive EEE LPI
Sticky bit.
1: Disable transmission of EEE LPI on receive
path MAC interface in 1000BASE-T mode when
receiving LPI from the MDI.
1. 17E2 bits 4:0 are for debugging purposes only, not for operational use.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
71
Registers
4.4.3
Ring Resiliency Control
The following table shows the register settings for the ring resiliency controls at address 30E2.
Table 62 • Ring Resiliency, Address 30E2
Bit
Name
Access Description
Default
15
Ring resiliency
startup enable
R/W
Sticky
0
(master TR enable)
14
13
12
Advertise ring
resiliency
R/W
RO
Sticky
0
0
0
LP ring resiliency
advertisement
Force ring resiliency R/W
enable (override
autoneg)
Sticky
11:6
5:4
Reserved
RO
RO
Reserved
000000
00
Ring resiliency
status
Ring resiliency status (from r1000 DSP SM)
00: Timing slave(1)
10: Timing slave becoming master
11: Timing master(1)
01: Timing master becoming slave
3:1
0
Reserved
RO
Reserved
000
0
Start switchover
(only when not in
progress)
RWSC
1. Reflects autoneg master/slave at initial link-up
4.5
Extended Page 3 Registers
To access the extended page 3 registers (16E3–30E3), enable extended register access by writing
0x0003 to register 31. For more information, see Table 46, page 62.
When extended page 3 register access is enabled, reads and writes to registers 16–30 affect the
extended registers 16E3–30E3 instead of those same registers in the IEEE-specified register space.
Registers 0–15 are not affected by the state of the extended page register access.
Writing 0x0000 to register 31 restores the main register access.
The following table lists the addresses and register names in the extended register page 3 space. These
registers are accessible only when the device register 31 is set to 0x0003.
Table 63 • Extended Registers Page 3 Space
Address Name
16E3
17E3
18E3
19E3
20E3
21E3
22E3
MAC SerDes PCS Control
MAC SerDes PCS Status
MAC SerDes Clause 37 Advertised Ability
MAC SerDes Clause 37 Link Partner Ability
MAC SerDes Status
Media SerDes Transmit Good Packet Counter
Media SerDes Transmit CRC Error Counter
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
72
Registers
Table 63 • Extended Registers Page 3 Space (continued)
Address Name
23E3
24E3
25E3
26E3
27E3
28E3
29E3
30E3
Media SerDes PCS Control
Media SerDes PCS Status
Media SerDes Clause 37 Advertised Ability
Media SerDes Clause 37 Link Partner Ability
Media SerDes status
Fiber Media CRC Good Counter
Fiber Media CRC Error Counter
Reserved
4.5.1
MAC SerDes PCS Control
The register at address 16E3 consists of the bits that provide access to and control over MAC SerDes
PCS block. The following table shows the settings available.
Table 64 • MAC SerDes PCS Control, Address 16E3 (0x10)
Bit
Name
Access Description
Default
15
MAC interface disable
R/W
R/W
Sticky bit.
0
1: 1000BASE-X MAC interface disable when
media link down.
14
13
MAC interface restart
Sticky bit.
0
0
0
1: 1000BASE-X MAC interface restart on
media link change.
MAC interface PD enable R/W
Sticky bit.
1: MAC interface autonegotiation parallel
detect enable.
12
11
MAC interface
autonegotiation restart
R/W
R/W
Self-clearing bit.
1: Restart MAC interface autonegotiation.
Force advertised ability
1: Force 16-bit advertised ability from register 0
18E3.
10:8 SGMII preamble control R/W
000: No effect on the start of packet.
001: If both the first two nibbles of the 10/100
packet are not 0x5, a byte of 0x55 must be
prefixed to the output, otherwise there will be
no effect on the start of packet.
001
010: If both the first two nibbles of the 10/100
packet are not 0x5, a byte of 0x55 must be
prefixed to the output. An additional byte of
0x55 must be prefixed to the output if the
next two nibbles are also not 0x5.
011–111: Reserved.
7
6
5
MAC SerDes
autonegotiation enable
R/W
1: MAC SerDes ANEG enable.
0
SerDes polarity at input of R/W
MAC
1: Invert polarity of signal received at input of 0
MAC.
SerDes polarity at output R/W
of MAC
1: Invert polarity of signal at output of MAC.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
73
Registers
Table 64 • MAC SerDes PCS Control, Address 16E3 (0x10) (continued)
Bit
Name
Access Description
Default
4
Fast link status enable
R/W
1: Use fast link fail indication as link status
0
indication to MAC SerDes.
0: Use normal link status indication to MAC
SerDes.
3
Reserved
Reserved
R/W
RO
Reserved.
Reserved.
0
2:0
4.5.2
MAC SerDes PCS Status
The register at address 17E3 consists of the bits that provide status from the MAC SerDes PCS block.
The following table shows the settings available.
Table 65 • MAC SerDes PCS Status, Address 17E3 (0x11)
Bit
Name
Access Description
15:13 Reserved
RO
RO
Reserved
12
11
SGMII alignment error
1: SGMII alignment error occurred
MAC interface LP autonegotiation RO
restart
1: MAC interface link partner autonegotiation
restart request occurred
10
Reserved
RO
RO
Reserved
9:8
MAC remote fault
01, 10, and 11: Remote fault detected from
MAC
00: No remote fault detected from MAC
7
6
5
4
3
Asymmetric pause advertisement RO
1: Asymmetric pause advertised by MAC
1: Symmetric pause advertised by MAC
1: Full duplex advertised by MAC
Symmetric pause advertisement
Full duplex advertisement
Half duplex advertisement
RO
RO
RO
1: Half duplex advertised by MAC
MAC interface LP autonegotiation RO
capable
1: MAC interface link partner autonegotiation
capable
2
1
MAC interface link status
RO
RO
1: MAC interface link status connected
MAC interface autonegotiation
complete
1: MAC interface autonegotiation complete
0
MAC comma detect
RO
1: Comma currently detected
0: comma currently not detected
4.5.3
MAC SerDes Clause 37 Advertised Ability
The register at address 18E3 consists of the bits that provide access to and control over MAC SerDes
Clause 37 advertised ability. The following table shows the settings available.
Table 66 • MAC SerDes Cl37 Advertised Ability, Address 18E3 (0x12)
Bit Name Access Description
Default
15:0 MAC SerDes advertised R/W
ability
Current configuration code word being
advertised (this register is read/write if
16E3.11 = 1)
0x0000
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
74
Registers
4.5.4
MAC SerDes Clause 37 Link Partner Ability
The register at address 19E3 consists of the bits that provide status of the MAC SerDes link partner's
Clause 37 advertised ability. The following table shows the settings available.
Table 67 • MAC SerDes Cl37 LP Ability, Address 19E3 (0x13)
Bit
Name
Access Description
15:0 MAC SerDes LP ability RO
Last configuration code word received from link partner
4.5.5
MAC SerDes Status
The register at address 20E3 consists of the bits that provide access to MAC SerDes status. The
following table shows the settings available.
Table 68 • MAC SerDes Status, Address 20E3 (0x14)
Bit
15
14
Name
Access Description
Reserved
RO
RO
Reserved
MAC comma detect
Super-sticky bit. Cleared upon SW reset.
1: Comma detected
0: Comma not detected
13
QSGMII sync status
RO
RO
12:0 Reserved
Reserved
4.5.6
4.5.7
Media SerDes Transmit Good Packet Counter
The register at address 21E3 consists of the bits that provide status of the media SerDes transmit good
packet counter. The following table shows the settings available.
Table 69 • Media SerDes Tx Good Packet Counter, Address 21E3 (0x15)
Bit
15
14
Name
Access Description
Tx good packet counter active RO
1: Transmit good packet counter active
Reserved
Reserved
RO
RO
13:0 Tx good packet count
Transmit good packet count modulo 10000
Media SerDes Transmit CRC Error Counter
The register at address 22E3 consists of the bits that provide status of the media SerDes transmit packet
count that had a CRC error. The following table shows the settings available.
Table 70 • Media SerDes Tx CRC Error Counter, Address 22E3 (0x16)
Bit
15:8 Reserved
7:0 Tx CRC packet count RO
Name
Access Description
RO
Reserved
Transmit CRC packet count (saturates at 255)
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
75
Registers
4.5.8
Media SerDes PCS Control
The register at address 23E3 consists of the bits that provide access to and control over Media SerDes
PCS control. The following table shows the settings available.
Table 71 • Media SerDes PCS Control, Address 23E3 (0x17)
Bit
Name
Access Description
Default
15:14 Reserved
RO
Reserved
13
Media interface autonegotiation R/W
parallel-detection
Sticky bit.
1: SerDes media autonegotiation
parallel detect enabled
0
12
11
Reserved
RO
Reserved
Force advertised ability
R/W
1: Force 16-bit advertised ability
from register 25E3.15:0
0
0
10:7
6
Reserved
RO
Reserved
Polarity reversal input
Media SerDes polarity reversal
input
0: No polarity reversal (default)
1: Polarity reversed
5
Polarity reversal output
Reserved
Media SerDes polarity reversal
output
0: No polarity reversal (default)
1: Polarity reversed
0
4:0
RO
Reserved
4.5.9
Media SerDes PCS Status
The register at address 24E3 consists of the bits that provide status of the Media SerDes PCS block. The
following table shows the settings available.
Table 72 • Media SerDes PCS Status, Address 24E3 (0x18)
Bit
Name
Access Description
15:14 Reserved
RO
RO
RO
RO
Reserved
13
12
11
SerDes protocol transfer
100 Mb or 100BASE-FX link status
10 Mb link status
SerDes protocol transfer
Media interface link partner
autonegotiation restart
1: Media interface link partner
autonegotiation restart request
occurred
10
Reserved
RO
RO
Reserved
9:8
Remote fault detected
01, 10, 11: Remote fault detected
from link partner
7
6
5
4
Link partner asymmetric pause RO
1: Asymmetric pause advertised by
link partner
Link partner symmetric pause
RO
RO
RO
1: Symmetric pause advertised by
link partner
Link partner full duplex
advertisement
1: Full duplex advertised by link
partner
Link partner half duplex
advertisement
1: Half duplex advertised by link
partner
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
76
Registers
Table 72 • Media SerDes PCS Status, Address 24E3 (0x18) (continued)
Bit
Name
Access Description
3
Link partner autonegotiation
capable
RO
1: Media interface link partner
autonegotiation capable
2
1
Media interface link status
RO
1: Media interface link status
Media interface autonegotiation RO
complete
1: Media interface autonegotiation
complete
0
Media interface signal detect
RO
1: Media interface signal detect
4.5.10 Media SerDes Clause 37 Advertised Ability
The register at address 25E3 consists of the bits that provide access to and control over Media SerDes
Clause 37 advertised ability. The following table shows the settings available.
Table 73 • Media SerDes Cl37 Advertised Ability, Address 25E3 (0x19)
Bit
Name
Access Description
Default
15:0 Media SerDes
advertised ability
R/W
Current configuration code word being advertised. 0x0000
This register is read/write when 23E3.11 = 1.
4.5.11 Media SerDes Clause 37 Link Partner Ability
The register at address 26E3 consists of the bits that provide status of the media SerDes link partner's
Clause 37 advertised ability. The following table shows the settings available.
Table 74 • MAC SerDes Cl37 LP Ability, Address 26E3 (0x1A)
Bit
Name
Access Description
15:0 Media SerDes LP ability RO
Last configuration code word received from link partner
4.5.12 Media SerDes Status
The register at address 27E3 consists of the bits that provide access to Media SerDes status. The
following table shows the settings available.
Table 75 • Media SerDes Status, Address 27E3 (0x1B)
Bit
Name
Access Description
15
K28.5 comma realignment RO
Self-clearing bit.
1: K28.5 comma re-alignment has occurred
14
Signal detect
RO
RO
Self-clearing bit. Sticky bit.
1: SerDes media signal detect
13:0 Reserved
Reserved
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
77
Registers
4.5.13 Fiber Media CRC Good Counter
Register 28E3 makes it possible to read the contents of the CRC good counter for packets that are
received on the Fiber media interface; the number of CRC routines that have executed successfully. The
following table shows the expected readouts.
Table 76 • Fiber Media CRC Good Counter, Address 28E3 (0x1C)
Bit
Name
Access Description
Default
15
Packet since last read RO
Self-clearing bit.
0
1: Packet received since last read.
14
Reserved
RO
Reserved.
13:0 Fiber media CRC good RO
counter contents
Self-clearing bit. Counter containing the
number of packets with valid CRCs. This
counter does not saturate and will roll over.
0x000
4.5.14 Fiber Media CRC Error Counter
Register 29E3 makes it possible to read the contents of the CRC error counter for packets that are
received on the Fiber media interface. The following table shows the expected readouts.
Table 77 • Fiber Media CRC Error Counter, Address 29E3 (0x1D)
Bit
Name
Access Description
Default
15:8 Reserved
RO
Reserved.
7:0
Fiber Media CRC RO
error counter
Self-clearing bit. CRC error counter for packets
received on the Fiber media interface. The value
saturates at 0xFF and subsequently clears when
read and restarts count.
0x00
4.6
General Purpose Registers
Accessing the general purpose register space is similar to accessing the extended page registers. Set
register 31 to 0x0010. This sets all 32 registers to the general purpose register space.
To restore main register page access, write 0x0000 to register 31.
The following table lists the addresses and register names in the general purpose register page space.
These registers are accessible only when the device register 31 is set to 0x0010. All general purpose
register bits are super-sticky.
Table 78 • General Purpose Registers Page Space
Address Name
0G–12G Reserved
13G
14G
15G
16G
17G
18G
19G
20G
LED/SIGDET/GPIO Control
GPIO Control 2
GPIO Input
GPIO Output
GPIO Output Enable
Micro Command
MAC Mode and Fast Link Configuration
Two-Wire Serial MUX Control 1
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
78
Registers
Table 78 • General Purpose Registers Page Space (continued)
Address Name
21G
22G
23G
24G
25G
26G
27G
28G
29G
30G
Two-Wire Serial MUX Control 2
Two-Wire Serial MUX Data Read/Write
Recovered Clock 0 Control
Recovered Clock 1 Control
Enhanced LED Control
Reserved
Reserved
Reserved
Global Interrupt Status
Reserved
4.6.1
4.6.2
Reserved General Purpose Address Space
The bits in registers 0G to 12G and 30G of the general purpose register space are reserved.
SIGDET/GPIO Control
The SIGDET control bits configure the GPIO[3:0]/SIGDET[3:0] pins to function either as signal detect
pins for each fiber media port, or as GPIOs. The following table shows the values that can be written.
Table 79 • SIGDET/GPIO Control, Address 13G (0x0D)
Bit
Name
Access Description
Default
15:14 GPIO7/I2C_SCL_3 R/W
13:12 GPIO6/I2C_SCL_2 R/W
11:10 GPIO5/I2C_SCL_1 R/W
00: SCL for PHY3
01: Reserved
10: Reserved
11: Controlled by MII registers 15G to 17G
00
00: SCL for PHY2
01: Reserved
10: Reserved
11: Controlled by MII registers 15G to 17G
00
00
00
00
00
00: SCL for PHY1
01: Reserved
10: Reserved
11: Controlled by MII registers 15G to 17G
9:8
7:6
5:4
GPIO4/I2C_SCL_0 R/W
00: SCL for PHY0
01: Reserved
10: Reserved
11: Controlled by MII registers 15G to 17G
GPIO3/SIGDET3
control
R/W
R/W
00: SIGDET operation
01: Reserved
10: Reserved
11: Controlled by MII registers 15G to 17G
GPIO2/SIGDET2
control
00: SIGDET operation
01: Reserved
10: Reserved
11: Controlled by MII registers 15G to 17G
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
79
Registers
Table 79 • SIGDET/GPIO Control, Address 13G (0x0D) (continued)
Bit
Name
Access Description
Default
3:2
GPIO1/SIGDET1
control
R/W
00: SIGDET operation
01: Reserved
00
10: Reserved
11: Controlled by MII registers 15G to 17G
1:0
GPIO0/SIGDET0
control
R/W
00: SIGDET operation
01: Reserved
00
10: Reserved
11: Controlled by MII registers 15G to 17G
4.6.3
GPIO Control 2
The GPIO control 2 register configures the functionality of the COMA_MODE input pins, and provides
control for possible GPIO pin options.
Table 80 • GPIO Control 2, Address 14G (0x0E)
Bit
Name
Access Description
Default
15:14 GPIO12 and GPIO13
R/W
GPIO12 and GPIO13 control.
00: Reserved
01: Reserved.
10: Reserved.
11: GPIO12/GPIO13 operation. Controlled
by MII registers 15G to 17G.
13
12
COMA_MODE output
enable (active low)
R/W
R/W
1: COMA_MODE pin is an input.
0: COMA_MODE pin is an output.
1
0
COMA_MODE output
data
Value to output on the COMA_MODE pin
when it is configured as an output.
11
10
COMA_MODE input data RO
Data read from the COMA_MODE pin.
Tri-state enable for
two-wire serial bus
R/W
1: Tri-states two-wire serial bus output
signals instead of driving them high. This
allows those signals to be pulled above
VDD25 using an external pull-up resistor.
0: Drive two-wire serial bus output signals
to high and low values as appropriate.
1
1
0
9
Tri-state enable for LEDs R/W
1: Tri-state LED output signals instead of
driving them high. This allows the signals
to be pulled above VDDIO using an external
pull-up resistor.
0: Drive LED bus output signals to high and
low values.
8
Reserved
GPIO11
RO
Reserved
7:6
R/W
GPIO11 control.
00: Reserved
01: Reserved
10: Reserved
11: Controlled by MII registers 15G to 17G
5:4
GPIO10
R/W
GPIO10 control.
00: Reserved
01: Reserved
10: Reserved
11: Controlled by MII registers 15G to 17G
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
80
Registers
Table 80 • GPIO Control 2, Address 14G (0x0E) (continued)
Bit
Name
Access Description
Default
3:2
GPIO9/FASTLINK_FAIL
R/W
GPIO9/FASTLINK_FAIL control.
00: FASTLINK_FAIL operation
01: Reserved
10: Reserved
11: Controlled by MII registers 15G to 17G
1:0
GPIO8/I2C_SDA
R/W
GPIO8/I2C_SDA control.
00: I2C_SDA operation
01: Reserved
10: Reserved
11: Controlled by MII registers 15G to 17G
4.6.4
GPIO Input
The input register contains information about the input to the device GPIO pins. Read from this register to
access the data on the device GPIO pins. The following table shows the readout you can expect.
Table 81 • GPIO Input, Address 15G (0x0F)
Bit
Name
Access Description
Default
15:14 Reserved
RO
Reserved
13
12
11
10
9
GPIO13
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
GPIO13 input
0
0
0
0
0
0
0
0
0
0
0
0
0
0
GPIO12
GPIO12 input
GPIO11
GPIO11 input
GPIO10
GPIO10 input
GPIO9/FASTLINK_FAIL
GPIO8/I2C_SDA
GPIO7/I2C_SCL_3
GPIO6/I2C_SCL_2
GPIO5/I2C_SCL_1
GPIO4/I2C_SCL_0
GPIO3/SIGDET3
GPIO2/SIGDET2
GPIO1/SIGDET1
GPIO0/SIGDET0
GPIO9/FASTLINK_FAIL input
GPIO8/I2C_SDA input
GPIO7/I2C_SCL_3 input
GPIO6/I2C_SCL_2 input
GPIO5/I2C_SCL_1 input
GPIO4/I2C_SCL_0 input
GPIO3/SIGDET3 input
GPIO2/SIGDET2 input
GPIO1/SIGDET1 input
GPIO0/SIGDET0 input
8
7
6
5
4
3
2
1
0
4.6.5
GPIO Output
The output register allows you to access and control the output from the device GPIO pins. The following
table shows the values you can write.
Table 82 • GPIO Output, Address 16G (0x10)
Bit
Name
Access Description
Default
15:14 Reserved
RO
Reserved
13
12
GPIO13
GPIO12
R/W
R/W
GPIO13 output
GPIO12 output
0
0
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
81
Registers
Table 82 • GPIO Output, Address 16G (0x10) (continued)
Bit
11
10
9
Name
Access Description
Default
GPIO11
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
GPIO11 output
0
0
0
0
0
0
0
0
0
0
0
0
GPIO10
GPIO10 output
GPIO9/FASTLINK_FAIL
GPIO8/I2C_SDA
GPIO7/I2C_SCL_3
GPIO6/I2C_SCL_2
GPIO5/I2C_SCL_1
GPIO4/I2C_SCL_0
GPIO3/SIGDET3
GPIO2/SIGDET2
GPIO1/SIGDET1
GPIO0/SIGDET0
GPIO9/FASTLINK_FAIL output
GPIO8/I2C_SDA output
GPIO7/I2C_SCL_3 output
GPIO6/I2C_SCL_2 output
GPIO5/I2C_SCL_1 output
GPIO4/I2C_SCL_0 output
GPIO3/SIGDET3 output
GPIO2/SIGDET2 output
GPIO1/SIGDET1 output
GPIO0/SIGDET0 output
8
7
6
5
4
3
2
1
0
4.6.6
GPIO Pin Configuration
Register 17G in the GPIO register space controls whether a particular GPIO pin functions as an input or
an output. The following table shows the settings available.
Table 83 • GPIO Input/Output Configuration, Address 17G (0x11)
Bit
Name
Access Description
Default
15:14 Reserved
RO
Reserved
13
12
11
10
9
GPIO13
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
GPIO13 output enable
0
0
0
0
0
0
0
0
0
0
0
0
0
0
GPIO12
GPIO12 output enable
GPIO11
GPIO11 output enable
GPIO10
GPIO10 output enable
GPIO9/FASTLINK_FAIL
GPIO8/I2C_SDA
GPIO7/I2C_SCL_3
GPIO6/I2C_SCL_2
GPIO5/I2C_SCL_1
GPIO4/I2C_SCL_0
GPIO3/SIGDET3
GPIO2/SIGDET2
GPIO1/SIGDET1
GPIO0/SIGDET0
GPIO9/FASTLINK_FAIL output enable
GPIO8/I2C_SDA output enable
GPIO7/I2C_SCL_3 output enable
GPIO6/I2C_SCL_2 output enable
GPIO5/I2C_SCL_1 output enable
GPIO4/I2C_SCL_0 output enable
GPIO3/SIGDET3 output enable
GPIO2/SIGDET2 output enable
GPIO1/SIGDET1 output enable
GPIO0/SIGDET0 output
8
7
6
5
4
3
2
1
0
4.6.7
Microprocessor Command
Register 18G is a command register. Bit 15 tells the internal processor to execute the command. When
bit 15 is cleared the command has completed. Software needs to wait until bit 15 = 0 before proceeding
with the next PHY register access. Bit 14 = 1 typically indicates an error condition where the squelch
patch was not loaded. Use the following steps to execute the command:
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
82
Registers
1. Write desired command
2. Check bit 15 (move existing text)
3. Check bit 14 (if set, then error)
Note: Commands may take up to 25 ms to complete before bit 15 changes to 0.
Table 84 • Microprocessor Command Register, Address 18G
Command
Setting
0x80F0
0x80E0
Enable 4 ports MAC SGMII
Enable 4 ports MAC QSGMII
QSGMII transmitter control(1)
Enable 4 ports Media 1000BASE-X
Enable 4 ports Media 100BASE-FX
0x8FC1(2)
0x8FD1(2)
1. Contact your Microsemi representative for an initialization script that greatly simplifies the programming
of QSGMII transmit controls.
2. The “F” in the command has a bit representing each of the four PHYs. To exclude a PHY from the
configuration, set its bit to 0. For example, the configuration of PHY 3 and PHY 2 to 1000BASE-X would
be 1100 or a “C” and the command would be 0x8CC1.
4.6.8
MAC Configuration and Fast Link
Register 19G in the GPIO register space controls the MAC interface mode and the selection of the
source PHY for the fast link failure indication. The following table shows the settings available for the
GPIO9/FASTLINK-FAIL pin.
Table 85 • MAC Configuration and Fast Link Register, Address 19G (0x13)
Bit
Name
Access Description
Default
15:14 MAC configuration
R/W
Select MAC interface mode
00
00: SGMII
01: QSGMII
10: Reserved
11: Reserved
13:4
3:0
Reserved
RO
Reserved
Fast link failure port setting R/W
Select fast link failure PHY source 0xF
0000: Port0
0001: Port1
0010: Port2
0011: Port3
1100–1111: Output disabled
4.6.9
Two-Wire Serial MUX Control 1
The following table shows the settings available to control the integrated two-wire serial MUX.
Table 86 • Two-Wire Serial MUX Control 1, Address 20G (0x14)
Bit
Name
Access Description
Default
15:9 Two-wire serial
device address
R/W
Top 7 bits of the 8-bit address sent out on the two 0xA0
wire serial stream. The bottom bit is the
read/write signal, which is controlled by register
21G, bit 8. SFPs use 0xA0.
8:6
Reserved
RO
Reserved.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
83
Registers
Table 86 • Two-Wire Serial MUX Control 1, Address 20G (0x14) (continued)
Bit
Name
Access Description
Default
5:4
Two-wire serial SCL R/W
clock frequency
00: 50 kHz
01: 100 kHz
10: 400 kHz
11: 2 MHz
01
3
2
1
0
Two-wire serial MUX R/W
port 3 enable
1: Enabled.
0
0
0
0
0: Two-wire serial disabled. Becomes GPIO pin.
Two-wire serial MUX R/W
port 2 enable
1: Enabled.
0: Two-wire serial disabled. Becomes GPIO pin.
Two-wire serial MUX R/W
port 1 enable
1: Enabled.
0: Two-wire serial disabled. Becomes GPIO pin.
Two-wire serial MUX R/W
port 0 enable
1: Enabled.
0: Two-wire serial disabled. Two-wire serial MUX
port 0 becomes GPIO pin if serial LED function is
enabled, regardless of the settings of this bit.
4.6.10 Two-Wire Serial MUX Control 2
Register 21G is used to control the two-wire serial MUX for status and control of two-wire serial slave
devices.
Table 87 • Two-Wire Serial MUX Interface Status and Control, Address 21G (0x15)
Bit
Name
Access Description
Default
15
Two-wire serial MUX
ready
RO
1: Two-wire serial MUX is ready for read or
write
14:12 Reserved
RO
Reserved
11:10 PHY port Address
R/W
Specific VSC8504-01 PHY port being
addressed.
00
0
9
Enable two-wire serial
MUX access
R/W
Self-clearing bit.
1: Execute read or write through the two-wire
serial MUX based on the settings of register
bit 21G.8
8
Two-wire serial MUX
read or write
R/W
R/W
1: Read from two-wire serial MUX
0: Write to two-wire serial MUX
1
7:0
Two-wire serial MUX
address
Sets the address of the two-wire serial MUX 0x00
used to direct read or write operations.
4.6.11 Two-Wire Serial MUX Data Read/Write
Register 22G in the extended register space enables access to the two-wire serial MUX.
Table 88 • Two-Wire Serial MUX Data Read/Write, Address 22G (0x16)
Bit
Name
Access Description
Default
15:8 Two-wire serial MUX RO
read data
Eight-bit data read from two-wire serial MUX;
requires setting both register 21G.9 and 21G.8 to
1.
7:0
Two-wire serial MUX R/W
write data
Eight-bit data to be written to two-wire serial MUX. 0x00
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
84
Registers
4.6.12 Recovered Clock 1 Control
Register 23G in the extended register space controls the functionality of the recovered clock 1 output
signal.
Table 89 • Recovered Clock 1 Control, Address 23G (0x17)
Bit
Name
Access Description
R/W 1: Enable recovered clock 1 output
Default
15
Enable
0
RCVRDCLK1
0: Disable recovered clock 1 output
14:11 Clock source select R/W
Select bits for source PHY for recovered clock:
0000: PHY0
0000
0001: PHY1
0010: PHY2
0011: PHY3
0100–1111: Reserved
10:8
Clock frequency
select
R/W
RO
Select output clock frequency:
000: 25 MHz output clock
001: 125 MHz output clock
010: 31.25 MHz output clock
011–111: Reserved
000
7:6
5:4
Reserved
Reserved.
Clock squelch level R/W
Select clock squelch level
00: Automatically squelch clock to low when the
link is not up, is unstable, is up in a mode that
does not support the generation of a recovered
clock (1000BASE-T master or 10BASE-T), or is
up in EEE mode (100BASE-TX or 1000BASE-T
slave).
01: Same as 00 except that the clock is also
generated in 1000BASE-T master and 10BASE-T
link-up modes. This mode also generates a
recovered clock output in EEE mode during
reception of LP_IDLE.
10: Squelch only when the link is not up.
11: Disable clock squelch.
Note: A clock from the SerDes or Cu PHY
will be output on the recovered
clock output in this mode when the
link is down.
When the CLK_SQUELCH_IN pin is set high, it
squelches the recovered clocks regardless of bit
settings.
3
Reserved
RO
Reserved.
2:0
Clock selection for R/W
specified PHY
000: Serial media recovered clock
001: Copper PHY recovered clock
010: Copper PHY transmitter TCLK
011–111: Reserved
000
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
85
Registers
4.6.13 Recovered Clock 2 Control
Register 24G in the extended register space controls the functionality of the recovered clock 2 output
signal.
Table 90 • Recovered Clock 2 Control, Address 24G (0x18)
Bit
Name
Access Description
Enable recovered clock 2 output
Default
15
Enable RCVRDCLK2 R/W
0
14:11 Clock source select
R/W
Select bits for source PHY for recovered clock: 0000
0000: PHY0
0001: PHY1
0010: PHY2
0011: PHY3
0100–1111: Reserved
10:8
Clock frequency
select
R/W
Select output clock frequency:
000: 25 MHz output clock
001: 125 MHz output clock
010: 31.25 MHz output clock
011–111: Reserved
000
7:6
5:4
Reserved
RO
Reserved
Clock squelch level
R/W
Select clock squelch level:
00: Automatically squelch clock to low when the
link is not up, is unstable, is up in a mode that
does not support the generation of a recovered
clock (1000BASE-T master or 10BASE-T), or is
up in EEE mode (100BASE-TX or 1000BASE-T
slave).
01: Same as 00 except that the clock is also
generated in 1000BASE-T master and
10BASE-T link-up modes. This mode also
generates a recovered clock output in EEE
mode during reception of LP_IDLE
10: Squelch only when the link is not up
11: Disable clock squelch.
Note: A clock from the SerDes or Cu
PHY will be output on the
recovered clock output in this
mode when the link is down.
Note: A clock from the SerDes or Cu
PHY will be output on the
recovered clock output in this
mode when the link is down.
When the CLK_SQUELCH_IN pin is set high, it
squelches the recovered clocks regardless of
bit settings.
3
Reserved
RO
Reserved
2:0
Clock selection for
specified PHY
R/W
000: Serial media recovered clock
001: Copper PHY recovered clock
010–111: Reserved
000
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
86
Registers
4.6.14 Enhanced LED Control
The following table contains the bits to control advanced functionality of the parallel and serial LED
signals.
Table 91 • Enhanced LED Control, Address 25G (0x19)
Bit
Name
Access Description
R/W Programmable control for LED pulsing
Default
15:8 LED pulsing duty cycle
control
00
duty cycle when bit 30.12 is set to 1. Valid
settings are between 0 and 198. A setting
of 0 corresponds to a 0.5% duty cycle and
198 corresponds to a 99.5% duty cycle.
Intermediate values change the duty cycle
in 0.5% increments
7
Port 1 enhanced serial LED R/W
output enable
Enable the enhanced serial LED output
functionality for port 1 LED pins.
1: Enhanced serial LED outputs
0: Normal function
0
0
6
Port 0 enhanced serial LED R/W
output enable
Enable the enhanced serial LED output
functionality for port 0 LED pins.
1: Enhanced serial LED outputs
0: Normal function
5:3
Serial LED frame rate
selection
R/W
Select frame rate of serial LED stream
000: 2500 Hz frame rate
001: 1000 Hz frame rate
010: 500 Hz frame rate
011: 250 Hz frame rate
100: 200 Hz frame rate
101: 125 Hz frame rate
110: 40 Hz frame rate
111: Output basic serial LED stream
See Table 9, page 28.
2:1
Serial LED select
LED port swapping
R/W
R/W
Select which LEDs from each PHY to
enable on the serial stream
00: Enable all four LEDs of each PHY
01: Enable LEDs 2, 1 and 0 of each PHY
10: Enable LEDs 1 and 0 of each PHY
11: Enable LED 0 of each PHY
00
0
See LED Port Swapping, page 29.
4.6.15 Global Interrupt Status
The following table contains the interrupt status from the various sources to indicate which one caused
that last interrupt on the pin.
Table 92 • Global Interrupt Status, Address 29G (0x1D)
Bit
15:4
3
Name
Access Description
Reserved
RO
Reserved
PHY3 interrupt source(1) RO
PHY3 interrupt source indication
0: PHY3 caused the interrupt
1: PHY3 did not cause the interrupt
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
87
Registers
Table 92 • Global Interrupt Status, Address 29G (0x1D) (continued)
Bit
Name
Access Description
2
PHY2 interrupt source(1) RO
PHY1 interrupt source(1) RO
PHY0 interrupt source(1) RO
PHY2 interrupt source indication
0: PHY2 caused the interrupt
1: PHY2 did not cause the interrupt
1
0
PHY1 interrupt source indication
0: PHY1 caused the interrupt
1: PHY1 did not cause the interrupt
PHY0 interrupt source indication
0: PHY0 caused the interrupt
1: PHY0 did not cause the interrupt
1. This bit is set to 1 when the corresponding PHY’s Interrupt Status register 26 (0x1A) is read.
4.7
Clause 45 Registers to Support Energy Efficient Ethernet
and 802.3bf
This section describes the Clause 45 registers that are required to support energy efficient Ethernet.
Access to these registers is through the IEEE standard registers 13 and 14 (MMD access control and
MMD data or address registers) as described in section 4.2.11 and 4.2.12.
The following table lists the addresses and register names in the Clause 45 register page space. When
the link is down, 0 is the value returned for the x.180x addresses.
Table 93 • Clause 45 Registers Page Space
Address Name
1.1801
1.1803
1.1805
1.1807
3.1
Tx maximum delay through PHY
Tx minimum delay through PHY
Rx maximum delay through PHY
Rx minimum delay through PHY
PCS status 1
3.20
EEE capability
3.22
EEE wake error counter
4.1801
4.1803
4.1805
4.1807
7.60
Tx maximum delay through xMII (SGMII, QSGMII, including FIFO variations)
Tx minimum delay through xMII (SGMII, QSGMII, including FIFO variations)
Rx maximum delay through xMII (SGMII, QSGMII, including FIFO variations)
Rx minimum delay through xMII (SGMII, QSGMII, including FIFO variations)
EEE advertisement
7.61
EEE link partner advertisement
4.7.1
PCS Status 1
The bits in the PCS Status 1 register provide a status of the EEE operation from the PCS for the link that
is currently active.
Table 94 • PCS Status 1, Address 3.1
Bit
Name
Access Description
RO Reserved
15:12 Reserved
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
88
Registers
Table 94 • PCS Status 1, Address 3.1 (continued)
Bit
Name
Access Description
11
Tx LPI received
RO/LH 1: Tx PCS has received LPI
0: LPI not received
10
9
Rx LPI received
Tx LPI indication
Rx LPI indication
Reserved
RO/LH 1: Rx PCS has received LPI
0: LPI not received
RO
RO
RO
1: Tx PCS is currently receiving LPI
0: PCS is not currently receiving LPI
8
1: Rx PCS is currently receiving LPI
0: PCS is not currently receiving LPI
7:3
2
Reserved
PCS receive link status RO
1: PCS receive link up
0: PCS receive link down
1:0
Reserved RO
Reserved
4.7.2
EEE Capability
This register is used to indicate the capability of the PCS to support EEE functions for each PHY type.
The following table shows the bit assignments for the EEE capability register.
Table 95 • EEE Capability, Address 3.20
Bit
Name
Access Description
15:3 Reserved
RO
1000BASE-T EEE RO
Reserved
2
1
0
1: EEE is supported for 1000BASE-T
0: EEE is not supported for 1000BASE-T
100BASE-TX
EEE
RO
RO
1: EEE is supported for 100BASE-TX
0: EEE is not supported for 100BASE-TX
Reserved
Reserved
4.7.3
EEE Wake Error Counter
This register is used by PHY types that support EEE to count wake time faults where the PHY fails to
complete its normal wake sequence within the time required for the specific PHY type. The definition of
the fault event to be counted is defined for each PHY and can occur during a refresh or a wakeup as
defined by the PHY. This 16-bit counter is reset to all zeros when the EEE wake error counter is read or
when the PHY undergoes hardware or software reset.
Table 96 • EEE Wake Error Counter, Address 3.22
Bit
Name
Access Description
Count of wake time faults for a PHY
15:0 Wake error counter RO
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
89
Registers
4.7.4
EEE Advertisement
This register defines the EEE advertisement that is sent in the unformatted next page following a EEE
technology message code. The following table shows the bit assignments for the EEE advertisement
register.
Table 97 • EEE Advertisement, Address 7.60
Bit
Name
Access Description
Default
15:3 Reserved
RO
1000BASE-T EEE R/W
Reserved
2
1
0
1: Advertise that the 1000BASE-T has EEE
capability
0: Do not advertise that the 1000BASE-T has EEE
capability
0
100BASE-TX
EEE
R/W
RO
1: Advertise that the 100BASE-TX has EEE
capability
0: Do not advertise that the 100BASE-TX has EEE
capability
0
Reserved
Reserved
4.7.5
EEE Link Partner Advertisement
All the bits in the EEE LP Advertisement register are read only. A write to the EEE LP advertisement
register has no effect. When the AN process has been completed, this register will reflect the contents of
the link partner's EEE advertisement register. The following table shows the bit assignments for the EEE
advertisement register.
Table 98 • EEE Advertisement, Address 7.61
Bit
Name
Access Description
15:3 Reserved
RO
1000BASE-T EEE RO
Reserved
2
1
0
1: Link partner is advertising EEE capability for 1000BASE-T
0: Link partner is not advertising EEE capability for
1000BASE-T
100BASE-TX
EEE
RO
1: Link partner is advertising EEE capability for 100BASE-TX
0: Link partner is not advertising EEE capability for
100BASE-TX
Reserved
RO
Reserved
The following table shows the bit assignments for the 802.3bf registers. When the link is down, 0 is the
value returned. cl45reg1_1801 would be device address of 1 and register address of 1801.
Table 99 • 802.3bf Registers
Register
1.1801
1.1803
1.1805
1.1807
4.1801
Name
Function
cl45reg1_1801_val[15:0]
cl45reg1_1803_val[15:0]
cl45reg1_1805_val[15:0]
cl45reg1_1807_val[15:0]
cl45reg4_1801_val[15:0]
Tx maximum delay through PHY (PMA/PMD/PCS)
Tx minimum delay through PHY (PMA/PMD/PCS)
Rx maximum delay through PHY (PMA/PMD/PCS)
Rx minimum delay through PHY (PMA/PMD/PCS)
Tx maximum delay through xMII (SGMII, QSGMII,
including FIFO variations)
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
90
Registers
Table 99 • 802.3bf Registers (continued)
Register
Name
Function
4.1803
cl45reg4_1803_val[15:0]
Tx minimum delay through xMII (SGMII, QSGMII,
including FIFO variations)
4.1805
4.1807
cl45reg4_1805_val[15:0]
cl45reg4_1807_val[15:0]
Rx maximum delay through xMII (SGMII, QSGMII,
including FIFO variations)
Rx minimum delay through xMII (SGMII, QSGMII,
including FIFO variations)
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
91
Electrical Specifications
5
Electrical Specifications
This section provides the DC characteristics, AC characteristics, recommended operating conditions,
and stress ratings for the VSC8504-01 device.
5.1
DC Characteristics
This section contains the DC specifications for the VSC8504-01 device.
5.1.1
VDD25
The following table shows the DC specifications for the pins referenced to VDD25. The specifications
listed in the following table are valid only when VDD1 = 1.0 V, VDD1A = 1.0 V, or VDD25A = 2.5 V.
Table 100 • VDD25 DC Characteristics
Parameter
Symbol Minimum Maximum Unit Condition
Output high voltage
Output low voltage
Input high voltage
Input low voltage
Input leakage current
VOH
VOL
VIH
2.0
2.8
0.4
3.3
0.7
32
32
6
V
IOH = –1.0 mA
IOL = 1.0 mA
–0.3
1.85
–0.3
–32
–32
V
V
VIL
V
IILEAK
µA
µA
mA
Internal resistor included
Internal resistor included
Output leakage current IOLEAK
Output low current drive IOL
strength
Output high current drive IOH
strength
–6
mA
5.1.2
LED and GPIO
The following table shows the DC specifications for the LED and GPIO pins.
Table 101 • LED and GPIO Characteristics
Pin
Symbol
IOH
Minimum
–24
Maximum
Unit
mA
mA
mA
mA
LED
LED
GPIO
GPIO
24
IOL
IOH
12
IOL
–12
5.1.3
Internal Pull-Up or Pull-Down Resistors
Internal pull-up or pull-down resistors are specified in the following table. For more information about
signals with internal pull-up or pull-down resistors, see Pins by Function, page 110.
All internal pull-up resistors are connected to their respective I/O supply.
Table 102 • Internal Pull-Up or Pull-Down Resistors
Parameter
Symbol
Minimum Typical Maximum Unit
33 53 90 kΩ
Internal pull-up resistor, GPIO
RPU_GPIO
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
92
Electrical Specifications
Table 102 • Internal Pull-Up or Pull-Down Resistors (continued)
Parameter
Symbol
RPU
Minimum Typical Maximum Unit
Internal pull-up resistor, all others
Internal pull-down resistor
96
96
120
120
144
144
kΩ
kΩ
RPD
5.1.4
Reference Clock
The following table shows the DC specifications for a differential reference clock input signal
Table 103 • Reference Clock DC Characteristics
Parameter
Symbol Minimum
Typical
Maximum
1260
Unit
mV
mV
Input voltage range
VIP,VIN
|VID|
–25
Input differential peak-to-peak
voltage
1501
1200
Input common-mode voltage
Differential input impedance
VICM
RI
0
12002
mV
100
Ω
1. To meet jitter specifications, the minimum |VID| must be 400 mV. When using a single-ended clock input, the
REFCLK_P low voltage must be less than
VDDA – 200 mV, and the high voltage level must be greater than VDDA + 200 mV
2. The maximum common-mode voltage is provided without a differential signal. The common-mode voltage is
only limited by the maximum and minimum input voltage range and by the differential amplitude of the input
signal.
5.1.5
SerDes Interface (SGMII)
The SerDes output drivers are designed to operate in SGMII/LVDS mode. The SGMII/LVDS mode meets
or exceeds the DC requirements of Serial-GMII Specification Revision 1.9 (ENG-46158), unless
otherwise noted. The following table lists the DC specifications for the SGMII driver. The values are valid
for all configurations, unless stated otherwise.
Table 104 • SerDes Driver DC Specifications
Parameter
Symbol Minimum Maximum Unit Condition
Output high voltage, VOA or VOB
Output low voltage, VOA or VOB
Output differential peak voltage
VOH
VOL
1050
mV RL = 100 Ω ±1%
mV RL = 100 Ω ±1%
0
|VOD
|
350
450
450
580
140
mV VDD_VS = 1.0 V
RL = 100 Ω ±1%
Output differential peak voltage,
fiber media 1000BASE-X
|VOD
VOS
RO
|
350
420
40
mV VDD_VS = 1.0 V
RL = 100 Ω ±1%
Output offset voltage(1)
mV VDD_VS = 1.0 V
RL = 100 Ω ±1%
DC output impedance,
single-ended, SGMII mode
Ω
VC = 1.0 V
See Figure 40,
page 94
RO mismatch between A and B,
SGMII mode(2)
ΔRO
10
25
%
VC = 1.0 V
See Figure 40,
page 94
Change in |VOD| between 0 and 1, Δ|VOD
SGMII mode
|
mV
RL = 100 Ω ±1%
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
93
Electrical Specifications
Table 104 • SerDes Driver DC Specifications (continued)
Parameter Symbol Minimum Maximum Unit Condition
Change in VOS between 0 and 1, ΔVOS
25
40
12
mV RL = 100 Ω ±1%
SGMII mode
Output current, driver shorted to
GND, SGMII mode
|IOSA|,
|IOSB
mA
mA
|
Output current, drivers shorted
together, SGMII mode
|IOSAB|
1. Requires AC-coupling for SGMII compliance.
2. Matching of reflection coefficients. For more information about test methods, see IEEE Std 1596.3-1996.
Figure 38 • SGMII DC Transmit Test Circuit
VOA
V
OD = VOA – VOB
100 Ω ± 1%
VOS = ½ (VOA + VOB
)
VOB
Figure 39 • SGMII DC Definitions
VOA
VOB
GND
VOD
0 V differential
|VOD
|
|VOD
|
0 V differential
VOS
VOS
GND
Δ|VOD| = | |VOAH – VOBL| – |VOBH – VOAL| |
ΔVOS = | ½(VOAH + VOBL) – ½(VOAL + VOBH) |
Figure 40 • SGMII DC Driver Output Impedance Test Circuit
50 Ω ± 0.1%
VOA
+
–
Vc
0 and 1
VOB
50 Ω ± 0.1%
The following table lists the DC specifications for the SGMII receivers.
Table 105 • SerDes Receiver DC Specifications
Parameter
Symbol Minimum Maximum Unit Condition
Input voltage range, VIA or VIB
VI
–25
100
1250
1000
mV
mV
Input differential peak-to-peak
voltage
|VID|
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
94
Electrical Specifications
Table 105 • SerDes Receiver DC Specifications (continued)
Parameter
Symbol Minimum Maximum Unit Condition
(2)
Input common-mode voltage(1) VICM
0
VDD_A
mV Without any
differential signal
Receiver differential input
impedance
RI
80
25
120
Ω
Input differential hysteresis,
SGMII mode
VHYST
mV
1. SGMII compliancy requires external AC-coupling. When interfacing with specific Microsemi devices, DC-
coupling is possible. For more information, contact your local Microsemi sales representative.
2. The common-mode voltage is only limited by the maximum and minimum input voltage range and the
input signal’s differential amplitude.
Figure 41 • SGMII DC Input Definitions
VIA
VID = VIA – VIB
VIC = ½ (VIA + VIB)
VIB
5.1.6
Enhanced SerDes Interface (QSGMII)
All DC specifications for the enhanced SerDes interface are compliant with QSGMII Specification
Revision 1.3 and meet or exceed the requirements in the standard. They are also compliant with OIF-
CEI-02.0 requirements where applicable.
The enhanced SerDes interface supports the following operating modes: SGMII, QSGMII, and SFP. The
values in the following table apply to the modes specified in the condition column.
The following table shows the DC specifications for the enhanced SerDes driver.
Table 106 • Enhanced SerDes Driver DC Specifications
Parameter
Symbol Minimum Maximum Unit Condition
Output differential peak voltage,
SFP and QSGMII modes
|VODp
|
250
400
mV VDD_VS = 1.0 V
RL = 100 Ω ±1%
maximum drive
Output differential peak voltage,
SGMII mode(1)
|VODp
RO
|
150
40
400
140
mV VDD_VS = 1.0 V
RL = 100 Ω ±1%
DC output impedance,
single-ended, SGMII mode
Ω
VC = 1.0 V
See Figure 40,
page 94
RO mismatch between A and B,
SGMII mode(2)
ΔRO
10
%
VC = 1.0 V
See Figure 40,
page 94
Change in |VOD| between 0 and 1, Δ|VOD
|
25
25
mV
RL = 100 Ω ±1%
SGMII mode
Change in VOS between 0 and 1, ΔVOS
SGMII mode
mV RL = 100 Ω ±1%
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
95
Electrical Specifications
Table 106 • Enhanced SerDes Driver DC Specifications (continued)
Parameter
Symbol Minimum Maximum Unit Condition
Output current, drivers shorted to |IOSA|,
40
12
mA
ground, SGMII and QSGMII
modes
|IOSB
|
Output current, drivers shorted
together, SGMII and QSGMII
modes
|IOSAB
|
mA
1. Voltage is adjustable in 64 steps.
2. Matching of reflection coefficients. For more information about test methods, see IEEE Std 1596.3-1996.
The following table lists the DC specifications for the enhanced SerDes receiver.
Table 107 • Enhanced SerDes Receiver DC Specifications
Parameter
Symbol Minimum Typical Maximum Unit
(1)
Input voltage range, VIA or VIB
VI
–0.25
100
0
1.2
V
Input differential peak-to-peak voltage
Input common-mode voltage
|VID|
VICM
RI
1600
1200
120
mV
mV
Ω
Receiver differential input impedance
80
100
1. QSGMII DC input sensitivity is less than 400 mV.
5.1.7
Current Consumption
The following tables show the current consumption values for each mode. Add significant margin above
the values for sizing power supplies.
Table 108 • Current Consumption
Mode
Typical
Maximum
1 V 1 V
Unit Condition
1 V
1 V
2.5 V
2.5 V
2.5 V 2.5 V
Digital Analog Digital Analog Digital Analog Digital Analog
Reset
52
55
9
1
460
525
900
640
575
575
585
565
900
640
575
575
585
565
110
220
270
245
240
240
300
290
225
200
195
195
255
245
13
15
15
15
15
15
15
15
15
15
15
15
15
15
5
mA
mA
Power down
110
170
200
185
180
180
240
235
160
145
140
140
200
195
10
10
10
10
10
10
10
10
10
10
10
10
10
20
25
1000BASE-T 395
100BASE-TX 190
445
290
240
205
20
500
310
245
210
25
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
4-Port SGMII
4-Port SGMII
4-Port SGMII
4-Port SGMII
4-Port SGMII
4-Port SGMII
4-Port QSGMII
4-Port QSGMII
4-Port QSGMII
4-Port QSGMII
4-Port QSGMII
4-Port QSGMII
10BASE-T
10BASE-Te
145
145
1000BASE-X 155
100BASE-FX 140
1000BASE-T 390
100BASE-TX 185
20
25
460
305
255
220
35
500
310
245
210
25
10BASE-T
10BASE-Te
140
140
1000BASE-X 150
100BASE-FX 135
35
25
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
96
Electrical Specifications
5.1.8
Thermal Diode
The VSC8504-01 device includes an on-die diode and internal circuitry for monitoring die temperature
(junction temperature). The operation and accuracy of the diode is not guaranteed and should only be
used as a reference. Care should be taken to find compatible grounded cathode temperature monitoring
device.
A thermal sensor, located on the board or in a stand-alone measurement kit, can monitor and display the
die temperature of the switch for thermal management or instrumentation purposes.
Temperature measurement using a thermal diode is very sensitive to noise.
The following table provides the diode parameter and interface specifications. Note that the ThermDC pin
is connected to VSS internally in the device.
Table 109 • Thermal Diode Parameters
Parameter
Symbol
IFW
n
Typical
Maximum
Unit
Forward bias current
Diode ideality factor
1
mA
1.008
Note: Microsemi does not support or recommend operation of the thermal diode under reverse bias.
The ideality factor, n, represents the deviation from ideal diode behavior as exemplified by the diode
equation:
q
nkT
---------
Vd ×
IFW = IS ×
– 1
e
where, Is = saturation current, q = electronic charge, Vd = voltage across the diode, k = Boltzmann Constant, and T =
absolute temperature (Kelvin).
5.2
AC Characteristics
This section provides the AC specifications for the VSC8504-01 device.
5.2.1
Reference Clock
The following table shows the AC specifications for a 125 MHz differential reference clock source.
Performance is guaranteed for 125 MHz differential clocks only; however, 125 MHz single-ended clocks
are also supported for QSGMII interfaces.
25 MHz clock implementations are available but are limited to SGMII interfaces. For more information,
contact your Microsemi representative.
Table 110 • Reference Clock AC Characteristics for QSGMII 125 MHz Differential Clock
Parameter
Symbol
Minimum Typical Maximum Unit Condition
Reference clock
frequency,
ƒ
125.00
MHz ±100 ppm
REFCLK_SEL2 = 1
Duty cycle
DC
40
50
60
%
Rise time and fall time tr, tf
1.5
ns
20% to 80%
threshold
RefClk input RMS jitter
requirement, bandwidth
between 12 kHz and
500 kHz(1)
20
ps
To meet jitter
generation of 1G
output data per
IEEE 802.3z
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
97
Electrical Specifications
Table 110 • Reference Clock AC Characteristics for QSGMII 125 MHz Differential Clock (continued)
Parameter
Symbol
Minimum Typical Maximum Unit Condition
RefClk input RMS jitter
requirement, bandwidth
between 500 kHz and
15 MHz(1)
4
ps
ps
ps
dB
dB
To meet jitter
generation of 1G
output data per
IEEE 802.3z
RefClk input RMS jitter
requirement, bandwidth
between 15 MHz and
40 MHz(1)
20
100
0.3
3
To meet jitter
generation of 1G
output data per
IEEE 802.3z
RefClk input RMS jitter
requirement, bandwidth
between 40 MHz and
80 MHz(1)
To meet jitter
generation of 1G
output data per
IEEE 802.3z
Jitter gain from RefClk
to SerDes output,
bandwidth between
0 MHz and 0.1 MHz
Jitter gain from RefClk
to SerDes output,
1
bandwidth between
0.1 MHz and 7 MHz
Jitter gain from RefClk
to SerDes output,
1–20 × log
(ƒ/7 MHz)
3–20 × log dB
(ƒ/7 MHz)
bandwidth above 7 MHz
1. Maximum RMS jitter allowed at the RefClk input for the given bandwidth.
5.2.2
Recovered Clock
This section provides the AC characteristics for the recovered clock output signals. The following
illustration shows the test circuit for the recovered clock output signals.
Figure 42 • Test Circuit for Recovered Clock Output Signals
39 Ω
50 Ω
8 pF
Device Under Test
Signal Measurement Point
The following table shows the AC specifications for the RCVRDCLK1 and RCVRDCLK2 outputs.
Table 111 • Recovered Clock AC Characteristics
Parameter
Symbol
Minimum Typical Maximum Unit Condition
Recovered clock
frequency
ƒ
125.00
31.25
25.00
8.0
MHz
MHz
MHz
ns
Recovered clock
frequency
ƒ
ƒ
Recovered clock
frequency
Recovered clock cycle tRCYC
time
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
98
Electrical Specifications
Table 111 • Recovered Clock AC Characteristics (continued)
Parameter Symbol Minimum Typical Maximum Unit Condition
Recovered clock cycle tRCYC
time
32.0
ns
Recovered clock cycle tRCYC
time
40.0
ns
Frequency stability
ƒSTABILITY
50
60
ppm
%
Duty cycle, master
mode
DC
40
50
Clock rise time and
fall time
tR, tF
600
ps
ps
20% to 80%
Peak-to-peak jitter,
copper media
interface (master
mode)
JPPCLK_Cu
200
Jitter bandwidth
between 12 kHz
and 10 MHz
Peak-to-peak jitter,
fiber media interface,
100BASE-FX
JPPCLK_FiFX
1.2
ns
ps
Jitter bandwidth
between 12 kHz
and 80 MHz
Peak-to-peak jitter,
fiber media interface,
1000BASE-X
JPPCLK_FiX
200
Jitter bandwidth
between 12 kHz
and 80 MHz
5.2.3
SerDes Outputs
The values listed in the following table are valid for all configurations, unless otherwise noted.
Table 112 • SerDes Outputs AC Specifications
Parameter
Symbol
Minimum
Maximum Unit
Condition
VOD ringing compared to VRING
VS, SGMII mode
±10
200
30
%
RL = 100 Ω ±1%
VOD rise time and fall time, tR, tF
SGMII mode
100
ps
20% to 80% of VS
RL = 100 Ω ±1%
Differential peak-to-peak VOD
output voltage
mV
dB
dB
Tx disabled
Differential output return
loss, 50 MHz to 625 MHz
RLO_DIFF ≥10
RL = 100 Ω ±1%
RL = 100 Ω ±1%
Differential output return
loss, 625 MHz to
1250 MHz
RLO_DIFF 10–10 × log
(ƒ/625 MHz)
Common-mode return
loss, 50 MHz to 625 MHz
RLOCM
tSKEW
6
dB
ps
Interpair skew, SGMII
mode
20
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
99
Electrical Specifications
5.2.4
SerDes Driver Jitter
The following table lists the jitter characteristics for the SerDes output driver.
Table 113 • SerDes Driver Jitter Characteristics
Parameter
Symbol Maximum Unit Condition
Total jitter
TJO
192
80
ps
ps
Measured according to IEEE 802.3.38.5
Measured according to IEEE 802.3.38.5
Deterministic jitter DJO
5.2.5
SerDes Inputs
The following table lists the AC specifications for the SerDes inputs.
Table 114 • SerDes Input AC Specifications
Parameter
Maximum
Unit Condition
dB RL = 100 Ω ±1%
Differential input return loss, ≥10
50 MHz to 625 MHz
Differential input return loss, 10–10 × log (ƒ/625 MHz) dB
625 MHz to 1250 MHz
RL = 100 Ω ±1%
5.2.6
SerDes Receiver Jitter Tolerance
The following table lists jitter tolerances for the SerDes receiver.
Table 115 • SerDes Receiver Jitter Tolerance
Parameter
Symbol Minimum Unit Condition
Total jitter tolerance, greater than TJTI
637 kHz, SFP mode
600
370
1.4
ps
ps
ns
ns
ns
Measured according to
IEEE 802.3 38.6.8
Deterministic jitter tolerance,
greater than 637 kHz, SFP mode
DJTI
JTCD
DDJ
RJT
Measured according to
IEEE 802.3 38.6.8
Cycle distortion jitter tolerance,
100BASE-FX mode
Measured according to
ISO/IEC 9314-3:1990
Data-dependent jitter tolerance,
100BASE-FX mode
2.2
Measured according to
ISO/IEC 9314-3:1990
Random peak-to-peak jitter
2.27
Measured according to
ISO/IEC 9314-3:1990
tolerance, 100BASE-FX mode
5.2.7
Enhanced SerDes Interface
All AC specifications for the enhanced SerDes interface are compliant with QSGMII Specification
Revision 1.3 and meet or exceed the requirements in the standard. They are also compliant with the OIF-
CEI-02.0 requirements where applicable.
The enhanced SerDes interface supports the following modes of operation: SGMII, QSGMII, and SFP.
The values in the tables in the following sections apply to the QSGMII modes listed in the condition
column and are based on the test circuit shown in Figure 38, page 94. The transmit and receive eye
specifications relate to the eye diagrams shown in the following illustration, with the compliance load as
defined in the test circuit.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
100
Electrical Specifications
Figure 43 • QSGMII Transient Parameters
Transmitter Eye Mask
Receiver Eye Mask
T_Y2
T_Y1
0
R_Y2
R_Y1
0
–T_Y1
–T_Y2
–R_Y1
–R_Y2
0
T_X1
T_X2
1–T_X2 1–T_X1
1.0
0
R_X1
0.5
1–R_X1
1.0
Time (UI)
Time (UI)
5.2.7.1
Enhanced SerDes Outputs
The following table provides the AC specifications for the enhanced SerDes outputs in SGMII mode.
Table 116 • Enhanced SerDes Outputs AC Specifications, SGMII Mode
Parameter
Symbol Minimum
Maximum Unit Condition
Unit interval, 1.25G mode
VOD ringing compared to VS
UI
800 ps
VRING
±10
200
%
RL = 100 Ω ±1%
VOD rise time and fall time
tR, tF
100
ps
20% to 80% of VS
RL = 100 Ω ±1%
Differential peak-to-peak output VOD
voltage
30
mV Tx disabled
Differential output return loss, RLO_DIFF ≥10
dB
dB
dB
ps
RL = 100 Ω ±1%
RL = 100 Ω ±1%
50 MHz to 625 MHz
Differential output return loss, RLO_DIFF 10–10 × log
625 MHz to 1250 MHz
(ƒ/625 MHz)
Common-mode return loss,
50 MHz to 625 MHz
RLOCM
tSKEW
6
Intrapair skew
20
The following table provides the AC specifications for the enhanced SerDes outputs in QSGMII mode.
Table 117 • Enhanced SerDes Outputs AC Specifications, QSGMII Mode
Parameter
Symbol Minimum
Maximum Unit Condition
Unit interval, 5G
UI
200 ps
V
OD rise time and fall time tR, tF
30
96
30
ps
20% to 80% of VS
RL = 100 Ω ±1%
Differential peak-to-peak
output voltage
VOD
mV Tx disabled
Differential output return
loss, 100 MHz to 2.5 GHz
RLO_DIFF
8
dB
dB
RL = 100 Ω ±1%
RL = 100 Ω ±1%
Differential output return
loss, 2.5 GHz to 5 GHz
RLO_DIFF 8 dB – 16.6 log
(ƒ/2.5 GHz)
Eye mask X1
Eye mask X2
T_X1
T_X2
0.15
0.4
UI
UI
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
101
Electrical Specifications
Table 117 • Enhanced SerDes Outputs AC Specifications, QSGMII Mode
Parameter
Symbol Minimum
Maximum Unit Condition
Eye mask Y1
Eye mask Y2
T_Y1
T_Y2
200
mV
450
mV
5.2.7.2
Enhanced SerDes Driver Jitter Characteristics
The following table lists the jitter characteristics for the enhanced SerDes driver in QSGMII mode. For
information about jitter characteristics for the enhanced SerDes driver in SGMII mode, see Table 113,
page 100.
Table 118 • Enhanced SerDes Driver Jitter Characteristics, QSGMII Mode
Parameter
Symbol Maximum Unit Condition
Total output jitter
TJO
60
ps
Measured according to
IEEE 802.3.38.5.
Deterministic output jitter
DJO
10
ps
Measured according to
IEEE 802.3.38.5.
5.2.7.3
Enhanced SerDes Inputs
The following table lists the AC specifications for the enhanced SerDes inputs in SGMII mode.
Table 119 • Enhanced SerDes Input AC Specifications, SGMII Mode
Parameter
Symbol Minimum Unit Condition
Unit interval, 1.25G
UI
ps
800 ps
Differential input return loss,
50 MHz to 625 MHz
RLI_DIFF 10
dB
RL = 100 Ω ±1%
Common-mode input return loss, RLICM
50 MHz to 625 MHz
6
dB
The following table lists the AC specifications for the enhanced SerDes inputs in QSGMII mode.
Table 120 • Enhanced SerDes Inputs AC Specifications, QSGMII Mode
Parameter
Symbol Minimum
Maximum Unit Condition
Unit interval, 5G
UI
200 ps
Differential input return loss, RLI_DIFF
100 MHz to 2.5 GHz
8
dB
dB
dB
RL = 100 Ω ±1%
Differential input return loss, RLI_DIFF 8 dB – 16.6 log
2.5 GHz to 5 GHz
RL = 100 Ω ±1%
(ƒ/2.5 GHz)
Common-mode input return RLICM
loss, 100 MHz to 2.5 GHz
6
Eye mask X1
Eye mask Y1
Eye mask Y2
R_X1
R_Y1
R_Y2
0.3
50
UI
mV
mV
450
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
102
Electrical Specifications
5.2.7.4
Enhanced SerDes Receiver Jitter Tolerance
The following table lists the jitter tolerance for the enhanced SerDes receiver in QSGMII mode. For
information about jitter tolerance for the enhanced SerDes receiver in SGMII mode, see Table 115,
page 100.
Table 121 • Enhanced SerDes Receiver Jitter Tolerance, QSGMII Mode
Parameter
Symbol Maximum Unit Condition
Bounded high-probability jitter(1)
BHPJ
90
ps
92 ps peak-to-peak random
jitter and 38 ps sinusoidal jitter
(SJHF).
Sinusoidal jitter, maximum
Sinusoidal jitter, high frequency
Total jitter tolerance
SJMAX
SJHF
TJTI
1000
10
ps
ps
ps
120
92 ps peak-to-peak random
jitter and 38 ps sinusoidal jitter
(SJHF).
1. This is the sum of uncorrelated bounded high probability jitter (0.15 UI), and correlated bounded high
probability jitter (0.30 UI). Uncorrelated bounded high probability jitter is distribution where the value of the
jitter shows no correlation to any signal level being transmitted, formally defined as deterministic jitter (DJ).
Correlated bounded high probability jitter is jitter distribution where the value of the jitter shows a strong
correlation to the signal level being transmitted.
5.2.8
Basic Serial LEDs
This section contains the AC specifications for the basic serial LEDs.
Table 122 • Basic Serial LEDs AC Characteristics
Parameter
Symbol
Typical
Unit
ns
LED_CLK cycle time
tCYC
1024
Pause between LED port sequences tPAUSE_port 3072
ns
Pause between LED bit sequences tPAUSE_bit 25.541632 ms
LED_CLK to LED_DATA
tCO
1
ns
Figure 44 • Basic Serial LED Timing
tcyc
tPAUSE_port
LED_CLK
tco
LED_DATA
Bit 1
Bit 2
Bit X
Bit 1
5.2.9
Enhanced Serial LEDs
This section contains the AC specifications for the enhanced serial LEDs. The duty cycle of the
LED_PULSE signal is programmable and can be varied between 0.5% and 99.5%.
Table 123 • Enhanced Serial LEDs AC Characteristics
Parameter
Symbol Minimum Typical
tCYC 256
Maximum Unit
LED_CLK cycle time
ns
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
103
Electrical Specifications
Table 123 • Enhanced Serial LEDs AC Characteristics (continued)
Parameter
Symbol Minimum Typical
Maximum Unit
Pause between LED_DATA bit sequences tPAUSE
0.396
24.996
ms
ns
ns
ns
µs
LED_CLK to LED_DATA
LED_CLK to LED_LD
LED_LD pulse width
tCO
127
256
128
tCL
tLW
LED_PULSE cycle time
tPULSE
199
201
Figure 45 • Enhanced Serial LED Timing
tcyc
tpause
LED_CLK
tcl
tco
Bit 1
LED_DATA
Bit 2
Bit X
Bit 1
Bit 2
tlw
LED_LD
tpulse
LED_PULSE
5.2.10 JTAG Interface
This section provides the AC specifications for the JTAG interface. The specifications meet or exceed the
requirements of IEEE 1149.1-2001. The JTAG receive signal requirements are requested at the pin of
the device. The JTAG_TRST signal is asynchronous to the clock, and does not have a setup or hold time
requirement.
Table 124 • JTAG Interface AC Specifications
Parameter
Symbol Minimum Maximum Unit Condition
TCK frequency
TCK cycle time
TCK high time
TCK low time
ƒ
10
MHz
ns
tC
100
40
40
10
10
tW(CH)
tW(CL)
tSU
ns
ns
Setup time to TCK rising
ns
Hold time from TCK rising tH
TDO valid after TCK falling tV(C)
ns
28
30
ns
CL = 10 pF
CL = 0 pF
TDO hold time from TCK
falling
tH(TDO)
0
ns
TDO disable time(1)
tDIS
ns
ns
See Figure 47, page 105.
TRST time low
tW(TL)
30
1. The pin begins to float when a 300 mV change from the actual VOH/VOL level occurs.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
104
Electrical Specifications
Figure 46 • JTAG Interface Timing Diagram
tc
TCK
tW(CH)
tW(CL)
TDI
TMS
tSU
tH
tV(C)
TDO
tH(TDO)
tDIS
See definition
nTRST
tW(TL)
Figure 47 • Test Circuit for TDO Disable Time
3.3 V
500 Ω
From output under test
500 Ω
5 pF
5.2.11 Serial Management Interface
This section contains the AC specifications for the serial management interface (SMI).
Table 125 • Serial Management Interface AC Characteristics
Parameter
Symbol Minimum Typical Maximum
Unit Condition
MDC
fCLK
2.5
12.5
MHz
frequency(1)
MDC cycle time tCYC
MDC time high tWH
80
20
20
10
400
50
ns
ns
ns
ns
MDC time low
tWL
tSU
50
Setup to MDC
rising
Hold from MDC tH
rising
10
ns
MDC rise time
tR
100
ns
MDC = 0: 1 MHz
MDC = 1:
tCYC × 10%(1)
MHz – fCLK maximum
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
105
Electrical Specifications
Table 125 • Serial Management Interface AC Characteristics (continued)
Parameter
Symbol Minimum Typical Maximum
Unit Condition
MDC fall time
tF
100
CYC × 10%(1)
t
MDC to MDIO
valid
tCO
10
300
ns
Time-dependant on
the value of the
external pull-up
resistor on the MDIO
pin
1. For fCLK above 1 MHz, the minimum rise time and fall time is in relation to the frequency of the MDC clock
period. For example, if fCLK is 2 MHz, the minimum clock rise time and fall time is 50 ns.
Figure 48 • Serial Management Interface Timing
tWL
tWH
MDC
tCYC
tSU
tH
MDIO
(write)
Data
tCO
MDIO
(read)
Data
5.2.12 Reset Timing
This section contains the AC specifications that apply to device reset functionality. The signal applied to
the NRESET input must comply with the specifications listed in the following table.
Table 126 • Reset Timing Specifications
Parameter
Symbol Minimum Maximum Unit
NRESET assertion time after power
supplies and clock stabilize
tW
2
ms
Recovery time from reset inactive to
device fully active
tREC
105
ms
NRESET pulse width
tW(RL)
100
105
ns
Wait time between NRESET de-assert tWAIT
and access of the SMI interface
ms
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
106
Electrical Specifications
5.3
Operating Conditions
The following table shows the recommended operating conditions for the VSC8504-01 device.
Table 127 • Recommended Operating Conditions
Parameter
Symbol Minimum Typical Maximum Unit
Power supply voltage for V
Power supply voltage for V
Power supply voltage for V
Power supply voltage for V
V
V
V
V
T
T
0.95
0.95
2.38
2.38
0
1.00
1.00
2.50
2.50
1.05
1.05
2.62
2.62
125
V
V
V
V
DD1
DD1
DD1A
DD25
DD25A
DD1A
DD25
DD25A
(1)
(1)
VSC8504-01 operating temperature
VSC8504-04 operating temperature
°C
°C
–40
125
1. Minimum specification is ambient temperature, and the maximum is junction temperature. For carrier
class applications, the maximum operating temperature is 110 °C junction.
5.4
Stress Ratings
This section contains the stress ratings for the VSC8504-01 device.
Warning Stresses listed in the following table may be applied to devices one at a time without causing
permanent damage. Functionality at or exceeding the values listed is not implied. Exposure to these
values for extended periods may affect device reliability.
Table 128 • Stress Ratings
Parameter
Symbol
Minimum Maximum Unit
Power supply voltage for core supply
Power supply voltage for analog circuits
Power supply voltage for analog circuits
Power supply voltage for digital I/O
Input voltage for GPIO and logic input pins
Storage temperature
V
V
V
V
–0.3
–0.3
–0.3
–0.3
1.10
1.10
2.75
2.75
3.3
V
V
VDD1
VDD1A
VDD25A
VDD25
V
V
V
T
–55
125
250
°C
V
S
Electrostatic discharge voltage, charged
device model
V
–250
ESD_CDM
(1)
Electrostatic discharge voltage, human body
model
V
See note
V
ESD_HBM
1. This device has completed all required testing as specified in the JEDEC standard JESD22-A114,
Electrostatic Discharge (ESD) Sensitivity Testing Human Body Model (HBM), and complies with a
Class 2 rating. The definition of Class 2 is any part that passes an ESD pulse of 2000 V, but fails an
ESD pulse of 4000 V.
Warning This device can be damaged by electrostatic discharge (ESD) voltage. Microsemi
recommends that all integrated circuits be handled with appropriate precautions. Failure to observe
proper handling and installation procedures may adversely affect reliability of the device.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
107
Pin Descriptions
6
Pin Descriptions
The VSC8504-01 device has 256 pins, which are described in this section.
The pin information is also provided as an attached Microsoft Excel file so that you can copy it
electronically. In Acrobat, double-click the attachment icon.
6.1
Pin Identifications
This section contains the pin descriptions for the VSC8504-01 device. The following table provides
notations for definitions of the various pin types.
Table 129 • Pin Type Symbol Definitions
Symbol Pin Type
Description
3V
3.3 V-tolerant pin.
Analog bias pin.
ABIAS
ADIFF
I
Analog bias
Analog differential Analog differential signal pair.
Input
Input without on-chip pull-up or pull-down resistor.
I/O
Bidirectional
No connect
Output
Bidirectional input or output signal.
No connect pins must be left floating.
Output signal.
NC
O
OD
OS
PD
PU
ST
Open drain
Open source
Pull-down
Pull-up
Open drain output.
Open source output.
On-chip pull-down resistor to VSS.
On-chip pull-up resistor to VDD_IO.
Input has Schmitt-trigger circuitry.
Schmitt-trigger
6.2
Pin Diagram
The following illustrations show the pin diagram for the VSC8504-01 device. For clarity, the device is
shown in two halves, the top left and top right.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
108
Pin Descriptions
Figure 49 • Pin Diagram, Top Left
1
2
3
4
5
6
7
8
A
B
C
D
E
F
NC_1
TXVPA_3
TXVPB_3
TXVPC_3
TXVPD_3
TXVPA_2
TXVPB_2
TXVPC_2
VSS_1
TXVNA_3
TXVNB_3
TXVNC_3
TXVND_3
VSS_3
TXVNA_2
VDD25A_3
VSS_7
TXVNB_2
VDD1A_1
VSS_8
TXVNC_2
VDD1A_2
VSS_9
REFCLK_N VDD25A_1 THERMDA
VDD25A_2
THERMDC_VSS
REFCLK_P
REF_FILT_A REF_REXT_A
VSS_6
REFCLK_SEL2
TMS
TDI
TRST
TCK
VDD25A_6
VSS_20
LED3_0
LED3_1
LED3_2
LED3_3
VDD1_1
VDD1_3
VDD1_5
VDD1_7
VDD1_9
VDD1_11
VSS_14
VSS_21
VSS_27
VSS_33
VSS_39
VSS_45
VSS_51
VSS_57
VSS_63
VDD1A_5
FIBROP_2
FIBRON_2
VSS_15
VSS_22
VSS_28
VSS_34
VSS_40
VSS_46
VSS_52
VSS_58
VSS_64
VDD1A_6
FIBRIP_2
FIBRIN_2
VSS_16
VSS_23
VSS_29
VSS_35
VSS_41
VSS_47
VSS_53
VSS_59
VSS_65
VDD1A_7
RDP_2
TDO
G
H
J
LED0_0
LED1_0
LED1_1
LED1_2
LED1_3
RESERVED_73
LED2_0
LED2_1
LED2_2
LED2_3
COMA_MODE
LED0_1
LED0_2
K
L
LED0_3
RESERVED_5
RESERVED_6
RESERVED_7
RESERVED_8
VSS_69
RESERVED_3 VDD1_13
M
N
P
R
T
MDINT
MDIO
NRESET
VDD25_2
VDD1_15
VDD1_17
RESERVED_71
RESERVED_72
MDC
VDD25_4 RESERVED_4 VDD25A_8
FIBROP_3
FIBRON_3
FIBRIP_3
FIBRIN_3
RDP_3
RDN_3
TDP_3
TDN_3
NC_3
RDN_2
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
109
Pin Descriptions
Figure 50 • Pin Diagram, Top Right
9
10
11
12
13
14
15
16
TXVPD_2
TXVPA_1
TXVPB_1
TXVPC_1
TXVPD_1
TXVPA_0
TXVPB_0
NC_2
A
B
C
D
E
F
TXVND_2
TXVNA_1
TXVNB_1
TXVNC_1
VSS_4
TXVND_1
TXVNA_0
TXVNB_0
TXVNC_0
TXVND_0
CLK_SQUELCH_IN
VSS_2
VDD1A_3 RESERVED_1 VDD25A_4
VDD1A_4 VDD25A_5
TXVPC_0
TXVPD_0
RESERVED_70
VSS_10
VSS_17
VSS_24
VSS_30
VSS_36
VSS_42
VSS_48
VSS_54
VSS_60
VSS_66
VDD1A_8
TDP_2
VSS_11
VSS_18
VSS_25
VSS_31
VSS_37
VSS_43
VSS_49
VSS_55
VSS_61
VSS_67
VSS_12
VSS_19
VSS_26
VSS_32
VSS_38
VSS_44
VSS_50
VSS_56
VSS_62
VSS_68
VSS_13
RESERVED_2
VDD25A_7
VSS_73
VSS_71
VSS_72
VDD1_2
VDD1_4
VDD1_6
VDD1_8
VDD1_10
VDD1_12
VDD1_14
VDD1_16
VDD1_18
PHYADD4
PHYADD3
GPIO13
VSS_74
VSS_75
RCVRDCLK1
PHYADD2
VDD25_1
VSS_78
RCVRDCLK2 G
VSS_76
VSS_77
H
J
RESERVED_18
RESERVED_19
GPIO12
GPIO9/FASTLINK-FAIL
GPIO8/I2C_SDA
GPIO4/I2C_SCL_0
GPIO10
GPIO11
K
L
GPIO5/I2C_SCL_1
GPIO6/I2C_SCL_2
GPIO7/I2C_SCL_3
GPIO1/SIGDET1 GPIO2/SIGDET2 GPIO3/SIGDET3
VDD25_3
M
N
P
R
T
SerDes_Rext_1 GPIO0/SIGDET0
SerDes_Rext_0
TDP_0
RDP_0
TDN_0
RDN_0
VSS_70
NC_4
VDD1A_9 VDD1A_10 VDD25A_9 VDD25A_10
FIBROP_1
FIBRON_1
FIBRIP_1
FIBRIN_1
RDP_1
RDN_1
TDP_1
TDN_1
FIBROP_0
FIBRON_0
FIBRIP_0
FIBRIN_0
TDN_2
6.3
Pins by Function
This section contains the functional pin descriptions for the VSC8504-01 device.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
110
Pin Descriptions
6.3.1
GPIO and SIGDET
The following table lists the GPIO and SIGDET pins.
Table 130 • GPIO and SIGDET Pins
Name
Pin
Type
Description
GPIO0/SIGDET0
GPIO1/SIGDET1
GPIO2/SIGDET2
GPIO3/SIGDET3
GPIO4/I2C_SCL_0
GPIO5/I2C_SCL_1
GPIO6/I2C_SCL_2
GPIO7/I2C_SCL_3
GPIO8/I2C_SDA
N14 I/O, PU, 3 V
General purpose input/output (GPIO). The
multipurpose SIGDET pins, two-wire serial
controller pins, and fast link fail pin can be
configured to serve as GPIOs.
M14
M15
M16
L13
L14
L15
L16
K13
GPIO9/FASTLINK-FAIL K14
GPIO10
GPIO11
GPIO12
GPIO13
K15
K16
J14
H14
6.3.2
JTAG
The following table lists the JTAG test pins.
Table 131 • JTAG Pins
Name Pin Type
Description
TCK
TDI
F3 I, PU, ST, 3 V
F2 I, PU, ST, 3 V
F1
E2 I, PU, ST, 3 V
JTAG test clock input.
JTAG test serial data input.
JTAG test serial data output.
JTAG test mode select.
TDO
TMS
O
TRST E3 I, PU, ST, 3 V
JTAG reset.
Important When JTAG is not in use, this pin must be tied to
ground with a pull-down resistor for normal operation.
6.3.3
Miscellaneous
The following table lists the miscellaneous pins.
Table 132 • Miscellaneous Pins
Name
Pin
Type
Description
CLK_SQUELCH_IN E15
I, PU,
3 V
Input control to squelch recovered clock.
COMA_MODE
L3
I, PU,
3 V
When this pin is asserted high, all PHYs are held
in a powered down state. When de-asserted low,
all PHYs are powered up and resume normal
operation. This signal is also used to synchronize
the operation of multiple chips on the same PCB to
provide visual synchronization for LEDs driven by
(1)
separate chips.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
111
Pin Descriptions
Table 132 • Miscellaneous Pins (continued)
Name
Pin
Type
Description
LED0_[0:3]
LED1_[0:3]
LED2_[0:3]
LED3_[0:3]
G1, H1, J1, K1
G2, H2, J2, K2
G3, H3, J3, K3
G4, H4, J4, K4
O
LED direct-drive outputs. All LEDs pins are
active-low. A serial LED stream can also be
implemented. See LED Mode Select, page 60.
Note: LEDbit_port, where port = PHY port
number and bit = the particular LED
for the port.
NC_1
NC_2
NC_3
NC_4
A1
A16
T1
NC
No connect.
T16
PHYADD2
PHYADD3
PHYADD4
G13
G14
F14
I, PD,
3 V
Device SMI address bits 4:2.
RCVRDCLK1
RCVRDCLK2
F16
G16
O
Clock output can be enabled or disabled and also
output a clock frequency of 125 MHz or 25 MHz
based on the selected active recovered media
programmed for this pin. This pin is not active
when NRESET is asserted. When disabled, the
pin is held low.
REF_FILT_A
D3
D4
ABIAS Reference filter connects to an external 1 µF
capacitor to analog ground.
REF_REXT_A
ABIAS Reference external connects to an external 2 kΩ
(1%) resistor to analog ground.
REFCLK_N
REFCLK_P
C1
D1
I,
125 MHz or 25 MHz reference clock input pair.
ADIFF Must be capacitively coupled and LVDS
compatible.
REFCLK_SEL2
E1
I, PU,
3 V
Selects the reference clock speed:
0: 25 MHz (VSS)
1: 125 MHz (2.5 V)
Use 125 MHz for typical applications.
RESERVED_[1:8]
C10, D13, L4,
P4, L1, M1, N1,
P1
NC
NC
Leave these pins unconnected (floating).
RESERVED_[18:19] J15, J16
Leave these pins unconnected (floating).
Leave these pins unconnected (floating).
Thermal diode anode.
RESERVED_[70:73] E16, N3, N4, L2 NC
THERMDA
C3
D2
A
A
THERMDC_VSS
Thermal diode cathode connected to device
ground. Temperature sensor must be chosen
accordingly.
1. For more information, see Initialization, page 43. For a typical bring-up example, see Configuration, page 42.
6.3.4
Power Supply
The following table lists the power supply pins and associated functional pins. All power supply pins must
be connected to their respective voltage input, even if certain functions are not used for a specific
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
112
Pin Descriptions
application. No power supply sequencing is required. However, clock and power must be stable before
releasing Reset.
Table 133 • Power Supply Pins
Name
Pin
Type Description
VDD1_[1:18]
E5, E12, F5, F12, G5, G12,
H5, H12, J5, J12, K5, K12,
L5, L12, M5, M12, N5, N12
1.0 V 1.0 V internal digital logic.
VDD1A_[1:10]
VDD25_[1:4]
C7, C8, C9, C13, P6, P7, P8, 1.0 V 1.0 V analog power requiring additional
P9, P10, P11
PCB power supply filtering. Associated
with the QSGMII/SGMII MAC receiver
output pins.
H13, M4, M13, P3
2.5 V 2.5 V general digital power supply.
Associated with the LED, GPIO, JTAG,
twisted pair interface, reference filter,
reference external supply connect, and
recovered clock pins.
VDD25A_[1:10] C2, C4, C6, C11, C14, E4,
E13, P5, P12, P13
2.5 V 2.5 V general analog power supply.
VSS_[1:4]
B1, B16, C5, C12
0 V
General device ground.
VSS_[6:78]
D5, D6, D7, D8, D9, D10,
D11, D12, E6, E7, E8, E9,
E10, E11, F4, F6, F7, F8, F9,
F10, F11, G6, G7, G8, G9,
G10, G11, H6, H7, H8, H9,
H10, H11, J6, J7, J8, J9, J10,
J11, K6, K7, K8, K9, K10,
K11, L6, L7, L8, L9, L10, L11,
M6, M7, M8, M9, M10, M11,
N6, N7, N8, N9, N10, N11,
R1, R16, D14, E14, F13, F15,
G15, H15, H16, J13
6.3.5
SGMII/SerDes/QSGMII MAC Interface
The following table lists the SerDes MAC interface pins.
Table 134 • SerDes MAC Interface Pins
Name
Pin Type
Description
RDN_0
RDP_0
P16 O, ADIFF PHY0 QSGMII/SGMII/SerDes MAC receiver output pair.
P15
RDN_1
RDN_2
RDN_3
RDP_1
RDP_2
RDP_3
T12 O, ADIFF SGMII/SerDes MAC receiver output pair.
T8
T4
R12
R8
R4
SerDes_Rext_0 P14 ABIAS
SerDes bias pins. Connect to a 620 Ω 1% resistor between
SerDes_Rext_0 and SerDes_Rext_1.
SerDes_Rext_1 N13 ABIAS
SerDes bias pins. Connect to a 620 Ω 1% resistor between
SerDes_Rext_0 and SerDes_Rext_1.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
113
Pin Descriptions
Table 134 • SerDes MAC Interface Pins (continued)
Name
Pin Type
Description
TDN_0
TDP_0
N16 I, ADIFF
N15
PHY0 QSGMII/SGMII/SerDes MAC transmitter input pair.
TDN_1
TDN_2
TDN_3
TDP_1
TDP_2
TDP_3
T13 I, ADIFF
T9
T5
R13
R9
R5
SGMII/SerDes MAC transmitter input pair.
6.3.6
SerDes Media Interface
The following table lists the SerDes media interface pins.
Table 135 • SerDes Media Interface Pins
Name
Pin Type
Description
FIBRIN_0 T15 I, ADIFF SerDes media receiver input pair.
FIBRIN_1 T11
FIBRIN_2 T7
FIBRIN_3 T3
FIBRIP_0 R15 I, ADIFF SerDes media receiver input pair.
FIBRIP_1 R11
FIBRIP_2 R7
FIBRIP_3 R3
FIBRON_0 T14 O, ADIFF SerDes media transmitter output pair.
FIBRON_1 T10
FIBRON_2 T6
FIBRON_3 T2
FIBROP_0 R14 O, ADIFF SerDes media transmitter output pair.
FIBROP_1 R10
FIBROP_2 R6
FIBROP_3 R2
6.3.7
Serial Management Interface
The following table lists the serial management interface (SMI) pins. The SMI pins are referenced to
VDD25 and can be set to a 2.5 V power supply.
Table 136 • SMI Pins
Name
Pin Type
P2 I, PD, 3 V
Description
MDC
Management data clock. A 0 MHz to 12.5 MHz reference input is
used to clock serial MDIO data into and out of the PHY.
MDINT
M2 I/O, OS, OD Management interrupt signal. Upon reset the device will configure
these pins as active-low (open drain) or active-high (open source)
based on the polarity of an external 10 kΩ resistor connection.
These pins can be tied together in a wired-OR configuration with
only a single pull-up or pull-down resistor.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
114
Pin Descriptions
Table 136 • SMI Pins (continued)
Name
Pin Type
Description
MDIO
N2 I/O, OD
Management data input/output pin. Serial data is written or read
from this pin bidirectionally between the PHY and Station Manager,
synchronously on the positive edge of MDC. One external pull-up
resistor is required at the Station Manager, and its value depends
on the MDC clock frequency and the total sum of the capacitive
loads from the MDIO pins.
NRESET M3 I, PD, ST, 3 V Device reset. Active low input that powers down the device and
sets all register bits to their default state.
6.3.8
Twisted Pair Interface
The following table lists the twisted pair interface pins.
Table 137 • Twisted Pair Interface Pins
Name
Pin
Type
Description
TXVNA_0
TXVNA_1
TXVNA_2
TXVNA_3
B14 ADIFF TX/RX channel A negative signal
B10
B6
B2
TXVNB_0
TXVNB_1
TXVNB_2
TXVNB_3
B15 ADIFF TX/RX channel B negative signal
B11
B7
B3
TXVNC_0
TXVNC_1
TXVNC_2
TXVNC_3
C15 ADIFF TX/RX channel C negative signal
B12
B8
B4
TXVND_0
TXVND_1
TXVND_2
TXVND_3
D15 ADIFF TX/RX channel D negative signal
B13
B9
B5
TXVPA_0
TXVPA_1
TXVPA_2
TXVPA_3
A14 ADIFF TX/RX channel A positive signal
A10
A6
A2
TXVPB_0
TXVPB_1
TXVPB_2
TXVPB_3
A15 ADIFF TX/RX channel B positive signal
A11
A7
A3
TXVPC_0
TXVPC_1
TXVPC_2
TXVPC_3
C16 ADIFF TX/RX channel C positive signal
A12
A8
A4
TXVPD_0
TXVPD_1
TXVPD_2
TXVPD_3
D16 ADIFF TX/RX channel D positive signal
A13
A9
A5
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
115
Quad-Port 10/100/1000BASE-T PHY with Synchronous Ethernet and QSGMII/SGMII
MAC
6.4
Pins by Number
This section provides a numeric list of the pins.
C7 VDD1A_1
E13 VDD25A_7
A1 NC_1
C8 VDD1A_2
C9 VDD1A_3
C10 RESERVED_1
C11 VDD25A_4
C12 VSS_4
E14 VSS_72
A2 TXVPA_3
A3 TXVPB_3
A4 TXVPC_3
A5 TXVPD_3
A6 TXVPA_2
A7 TXVPB_2
A8 TXVPC_2
A9 TXVPD_2
A10 TXVPA_1
A11 TXVPB_1
A12 TXVPC_1
A13 TXVPD_1
A14 TXVPA_0
A15 TXVPB_0
A16 NC_2
E15 CLK_SQUELCH_IN
E16 RESERVED_70
F1
F2
F3
F4
F5
F6
F7
F8
F9
TDO
TDI
C13 VDD1A_4
C14 VDD25A_5
C15 TXVNC_0
C16 TXVPC_0
D1 REFCLK_P
D2 THERMDC_VSS
D3 REF_FILT_A
D4 REF_REXT_A
D5 VSS_6
TCK
VSS_20
VDD1_3
VSS_21
VSS_22
VSS_23
VSS_24
F10 VSS_25
F11 VSS_26
F12 VDD1_4
F13 VSS_73
F14 PHYADD4
F15 VSS_74
F16 RCVRDCLK1
G1 LED0_0
G2 LED1_0
G3 LED2_0
G4 LED3_0
G5 VDD1_5
G6 VSS_27
G7 VSS_28
G8 VSS_29
G9 VSS_30
G10 VSS_31
G11 VSS_32
G12 VDD1_6
G13 PHYADD2
G14 PHYADD3
G15 VSS_75
G16 RCVRDCLK2
H1 LED0_1
H2 LED1_1
D6 VSS_7
D7 VSS_8
B1 VSS_1
D8 VSS_9
B2 TXVNA_3
B3 TXVNB_3
B4 TXVNC_3
B5 TXVND_3
B6 TXVNA_2
B7 TXVNB_2
B8 TXVNC_2
B9 TXVND_2
B10 TXVNA_1
B11 TXVNB_1
B12 TXVNC_1
B13 TXVND_1
B14 TXVNA_0
B15 TXVNB_0
B16 VSS_2
D9 VSS_10
D10 VSS_11
D11 VSS_12
D12 VSS_13
D13 RESERVED_2
D14 VSS_71
D15 TXVND_0
D16 TXVPD_0
E1
E2
E3
E4
E5
E6
E7
E8
E9
REFCLK_SEL2
TMS
TRST
VDD25A_6
VDD1_1
VSS_14
VSS_15
VSS_16
VSS_17
C1 REFCLK_N
C2 VDD25A_1
C3 THERMDA
C4 VDD25A_2
C5 VSS_3
E10 VSS_18
E11 VSS_19
E12 VDD1_2
C6 VDD25A_3
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
116
Pins by number (continued)
H3 LED2_1
H4 LED3_1
H5 VDD1_7
H6 VSS_33
H7 VSS_34
H8 VSS_35
H9 VSS_36
H10 VSS_37
H11 VSS_38
H12 VDD1_8
H13 VDD25_1
H14 GPIO13
H15 VSS_76
H16 VSS_77
K12 VDD1_12
N5 VDD1_17
N6 VSS_63
K13 GPIO8/I2C_SDA
K14 GPIO9/FASTLINK-FAIL
K15 GPIO10
N7 VSS_64
N8 VSS_65
K16 GPIO11
N9 VSS_66
L1
L2
L3
L4
L5
L6
L7
L8
L9
RESERVED_5
RESERVED_73
COMA_MODE
RESERVED_3
VDD1_13
N10 VSS_67
N11 VSS_68
N12 VDD1_18
N13 SerDes_Rext_1
N14 GPIO0/SIGDET0
N15 TDP_0
VSS_51
VSS_52
N16 TDN_0
VSS_53
P1
P2
P3
P4
P5
P6
P7
P8
P9
RESERVED_8
MDC
VSS_54
J1
J2
J3
J4
J5
J6
J7
J8
J9
LED0_2
LED1_2
LED2_2
LED3_2
VDD1_9
VSS_39
VSS_40
VSS_41
VSS_42
L10 VSS_55
VDD25_4
RESERVED_4
VDD25A_8
VDD1A_5
VDD1A_6
VDD1A_7
VDD1A_8
L11 VSS_56
L12 VDD1_14
L13 GPIO4/I2C_SCL_0
L14 GPIO5/I2C_SCL_1
L15 GPIO6/I2C_SCL_2
L16 GPIO7/I2C_SCL_3
M1 RESERVED_6
M2 MDINT
P10 VDD1A_9
P11 VDD1A_10
P12 VDD25A_9
P13 VDD25A_10
P14 SerDes_Rext_0
P15 RDP_0
J10 VSS_43
J11 VSS_44
J12 VDD1_10
J13 VSS_78
J14 GPIO12
J15 RESERVED_18
J16 RESERVED_19
K1 LED0_3
K2 LED1_3
K3 LED2_3
K4 LED3_3
K5 VDD1_11
K6 VSS_45
K7 VSS_46
K8 VSS_47
K9 VSS_48
K10 VSS_49
K11 VSS_50
M3 NRESET
M4 VDD25_2
M5 VDD1_15
M6 VSS_57
M7 VSS_58
P16 RDN_0
M8 VSS_59
R1 VSS_69
R2 FIBROP_3
R3 FIBRIP_3
R4 RDP_3
M9 VSS_60
M10 VSS_61
M11 VSS_62
M12 VDD1_16
R5 TDP_3
M13 VDD25_3
R6 FIBROP_2
R7 FIBRIP_2
R8 RDP_2
M14 GPIO1/SIGDET1
M15 GPIO2/SIGDET2
M16 GPIO3/SIGDET3
N1 RESERVED_7
N2 MDIO
R9 TDP_2
R10 FIBROP_1
R11 FIBRIP_1
R12 RDP_1
N3 RESERVED_71
N4 RESERVED_72
R13 TDP_1
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
117
Pins by number (continued)
R14 FIBROP_0
R15 FIBRIP_0
R16 VSS_70
T1
T2
T3
T4
T5
T6
T7
T8
T9
NC_3
FIBRON_3
FIBRIN_3
RDN_3
TDN_3
FIBRON_2
FIBRIN_2
RDN_2
TDN_2
T10 FIBRON_1
T11 FIBRIN_1
T12 RDN_1
T13 TDN_1
T14 FIBRON_0
T15 FIBRIN_0
T16 NC_4
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
118
Quad-Port 10/100/1000BASE-T PHY with Synchronous Ethernet and QSGMII/SGMII
MAC
6.5
Pins by Name
This section provides an alphabetic list of the pins.
LED1_2
LED1_3
LED2_0
LED2_1
LED2_2
LED2_3
LED3_0
LED3_1
LED3_2
LED3_3
MDC
J2
RESERVED_3
RESERVED_4
RESERVED_5
RESERVED_6
RESERVED_7
RESERVED_8
RESERVED_18
RESERVED_19
RESERVED_70
RESERVED_71
RESERVED_72
RESERVED_73
SerDes_Rext_0
SerDes_Rext_1
TCK
L4
CLK_SQUELCH_IN
COMA_MODE
FIBRIN_0
E15
L3
K2
P4
G3
H3
L1
T15
T11
T7
M1
N1
FIBRIN_1
J3
FIBRIN_2
K3
P1
FIBRIN_3
T3
G4
H4
J15
J16
E16
N3
FIBRIP_0
R15
R11
R7
FIBRIP_1
J4
FIBRIP_2
K4
FIBRIP_3
R3
P2
N4
FIBRON_0
T14
T10
T6
MDINT
M2
N2
L2
FIBRON_1
MDIO
P14
N13
F3
FIBRON_2
NC_1
A1
FIBRON_3
T2
NC_2
A16
T1
FIBROP_0
R14
R10
R6
NC_3
TDI
F2
FIBROP_1
NC_4
T16
M3
G13
G14
F14
F16
G16
P16
T12
T8
TDN_0
N16
T13
T9
FIBROP_2
NRESET
PHYADD2
PHYADD3
PHYADD4
RCVRDCLK1
RCVRDCLK2
RDN_0
TDN_1
FIBROP_3
R2
TDN_2
GPIO0/SIGDET0
GPIO1/SIGDET1
GPIO2/SIGDET2
GPIO3/SIGDET3
GPIO4/I2C_SCL_0
GPIO5/I2C_SCL_1
GPIO6/I2C_SCL_2
GPIO7/I2C_SCL_3
GPIO8/I2C_SDA
GPIO9/FASTLINK-FAIL
GPIO10
N14
M14
M15
M16
L13
L14
L15
L16
K13
K14
K15
K16
J14
H14
G1
TDN_3
T5
TDO
F1
TDP_0
N15
R13
R9
TDP_1
TDP_2
RDN_1
TDP_3
R5
RDN_2
THERMDA
THERMDC_VSS
TMS
C3
RDN_3
T4
D2
E2
RDP_0
P15
R12
R8
RDP_1
TRST
E3
RDP_2
TXVNA_0
TXVNA_1
TXVNA_2
TXVNA_3
TXVNB_0
TXVNB_1
TXVNB_2
TXVNB_3
TXVNC_0
B14
B10
B6
GPIO11
RDP_3
R4
GPIO12
REF_FILT_A
REF_REXT_A
REFCLK_N
REFCLK_P
REFCLK_SEL2
RESERVED_1
RESERVED_2
D3
D4
C1
GPIO13
B2
LED0_0
B15
B11
B7
LED0_1
H1
D1
E1
LED0_2
J1
LED0_3
K1
C10
D13
B3
LED1_0
G2
C15
LED1_1
H2
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
119
Pins by name (continued)
TXVNC_1
TXVNC_2
TXVNC_3
TXVND_0
TXVND_1
TXVND_2
TXVND_3
TXVPA_0
TXVPA_1
TXVPA_2
TXVPA_3
TXVPB_0
TXVPB_1
TXVPB_2
TXVPB_3
TXVPC_0
TXVPC_1
TXVPC_2
TXVPC_3
TXVPD_0
TXVPD_1
TXVPD_2
TXVPD_3
VDD1_1
VDD1_2
VDD1_3
VDD1_4
B12
B8
VDD1A_1
VDD1A_2
VDD1A_3
VDD1A_4
VDD1A_5
VDD1A_6
VDD1A_7
VDD1A_8
VDD1A_9
VDD1A_10
VDD25_1
VDD25_2
VDD25_3
VDD25_4
VDD25A_1
VDD25A_2
VDD25A_3
VDD25A_4
VDD25A_5
VDD25A_6
VDD25A_7
VDD25A_8
VDD25A_9
VDD25A_10
VSS_1
C7
VSS_19
VSS_20
VSS_21
VSS_22
VSS_23
VSS_24
VSS_25
VSS_26
VSS_27
VSS_28
VSS_29
VSS_30
VSS_31
VSS_32
VSS_33
VSS_34
VSS_35
VSS_36
VSS_37
VSS_38
VSS_39
VSS_40
VSS_41
VSS_42
VSS_43
VSS_44
VSS_45
VSS_46
VSS_47
VSS_48
VSS_49
VSS_50
VSS_51
VSS_52
VSS_53
VSS_54
VSS_55
VSS_56
VSS_57
VSS_58
VSS_59
E11
F4
C8
B4
C9
F6
D15
B13
B9
C13
P6
F7
F8
P7
F9
B5
P8
F10
F11
G6
G7
G8
G9
G10
G11
H6
H7
H8
H9
H10
H11
J6
A14
A10
A6
P9
P10
P11
H13
M4
M13
P3
A2
A15
A11
A7
A3
C2
C16
A12
A8
C4
C6
C11
C14
E4
A4
D16
A13
A9
E13
P5
J7
A5
P12
P13
B1
J8
E5
J9
E12
F5
J10
J11
K6
VSS_2
B16
C5
F12
G5
VSS_3
VDD1_5
VDD1_6
VDD1_7
VDD1_8
VDD1_9
VDD1_10
VDD1_11
VDD1_12
VDD1_13
VDD1_14
VDD1_15
VDD1_16
VDD1_17
VDD1_18
VSS_4
C12
D5
K7
G12
H5
VSS_6
K8
VSS_7
D6
K9
H12
J5
VSS_8
D7
K10
K11
L6
VSS_9
D8
J12
K5
VSS_10
D9
VSS_11
D10
D11
D12
E6
L7
K12
L5
VSS_12
L8
VSS_13
L9
L12
M5
VSS_14
L10
L11
M6
M7
M8
VSS_15
E7
M12
N5
VSS_16
E8
VSS_17
E9
N12
VSS_18
E10
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
120
Pins by name (continued)
VSS_60
VSS_61
VSS_62
VSS_63
VSS_64
VSS_65
VSS_66
VSS_67
VSS_68
VSS_69
VSS_70
VSS_71
VSS_72
VSS_73
VSS_74
VSS_75
VSS_76
VSS_77
VSS_78
M9
M10
M11
N6
N7
N8
N9
N10
N11
R1
R16
D14
E14
F13
F15
G15
H15
H16
J13
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
121
Package Information
7
Package Information
VSC8504XKS-01 and VSC8504XKS-04 are packaged in a lead(Pb)-free, 256-pin, plastic ball grid array
(BGA) with a 17 mm × 17 mm body size, 1 mm pin pitch, and 1.8 mm maximum height.
Lead(Pb)-free products from Microsemi comply with the temperatures and profiles defined in the joint
IPC and JEDEC standard IPC/JEDEC J-STD-020. For more information, see the IPC and JEDEC
standard.
This section provides the package drawing, thermal specifications, and moisture sensitivity rating for the
VSC8504-01 device.
7.1
Package Drawing
The following illustration shows the package drawing for the VSC8504-01 device. The drawing contains
the top view, bottom view, side view, dimensions, tolerances, and notes.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
122
Package Information
Figure 51 • Package Drawing
Top View
Bottom View
0.20 (4×)
Pin A1 corner
17.00
X
Pin A1 corner
16151413121110 9 8 7 6 5 4 3 2 1
A
B
C
D
E
F
G
H
J
1.00
15.00
17.00
K
L
M
N
P
R
T
1.00
Y
15.00
Side View
0.25 Z
0.20 Z
Z
4
Seating plane
Ø 0.45–0.64
5
Ø 0.25 M
Ø 0.10 M
Z
Z
X Y
Notes
1. All dimensions and tolerances are in millimeters (mm).
2. Ball diameter is 0.50 mm.
3. Radial true position is represented by typical values.
4. Primary datum Z and seating plane are defined by the
spherical crowns of the solder balls.
5. Dimension is measured at the maximum solder ball
diameter, parallel to primary datum Z.
7.2
Thermal Specifications
Thermal specifications for this device are based on the JEDEC JESD51 family of documents. These
documents are available on the JEDEC Web site at www.jedec.org. The thermal specifications are
modeled using a four-layer test board with two signal layers, a power plane, and a ground plane (2s2p
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
123
Package Information
PCB). For more information about the thermal measurement method used for this device, see the
JESD51-1 standard.
Table 138 • Thermal Resistances
Symbol
°C/W
5.9
Parameter
θ
Die junction to package case top
JCtop
θ
12.7
22
Die junction to printed circuit board
Die junction to ambient
JB
θ
JA
θ
θ
at 1 m/s
18.5
16.3
Die junction to moving air measured at an air speed of 1 m/s
Die junction to moving air measured at an air speed of 2 m/s
JMA
at 2 m/s
JMA
To achieve results similar to the modeled thermal measurements, the guidelines for board design
described in the JESD51 family of publications must be applied. For information about applications using
BGA packages, see the following:
•
•
JESD51-2A, Integrated Circuits Thermal Test Method Environmental Conditions, Natural Convection
(Still Air)
JESD51-6, Integrated Circuit Thermal Test Method Environmental Conditions, Forced Convection
(Moving Air)
•
•
JESD51-8, Integrated Circuit Thermal Test Method Environmental Conditions, Junction-to-Board
JESD51-9, Test Boards for Area Array Surface Mount Package Thermal Measurements
7.3
Moisture Sensitivity
This device is rated moisture sensitivity level 4 as specified in the joint IPC and JEDEC standard
IPC/JEDEC J-STD-020. For more information, see the IPC and JEDEC standard.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
124
Design Considerations
8
Design Considerations
This section provides information about design considerations for the VSC8504-01 device.
8.1
AMS and 100BASE-FX
When the PHY operating mode (set in register 23) is AMS and the current active media is 100BASE-FX,
register 0 bit 12 will be 0. This would normally indicate that auto-negotiation is disabled and the PHY is in
forced mode. But in this mode, it has other meanings.
The workaround is to ensure that bit 12 is always written as 1 when doing writes or updates to register 0
in AMS mode.
8.2
8.3
8.4
10BASE-T signal amplitude
10BASE-T signal amplitude can be lower than the minimum specified in IEEE 802.3 paragraph
14.3.1.2.1 (2.2 V) at low supply voltages.
This issue is not estimated to present any system level impact. Performance is not impaired with cables
up to 130 m with various link partners.
SNR degradation and link drops
The link may drop after approximately 100 master/slave relationship swaps with the ring resiliency
feature when using Category 5 (Cat5) cables that are longer than 75 m.
The workaround is to use a combination of an initialization script and a procedure change. Contact
Microsemi for the workaround solution if the ring resiliency feature is being enabled.
Clause 45 register 3.22
The clause 45, register 3.22 is cleared upon read only when the extended page access register (register
31) is set to 0.
This register cannot be read when the page access register is set to a value other than 0.
The workaround is to set extended page access register to 0 before accessing clause 45, register 3.22.
8.5
Clause 45 register 3.1
Clause 45, register 3.1, Rx and Tx LPI received bits are cleared upon read only when the extended page
access register (register 31) is set to 0.
This has a minor implication for software that needs to ensure that the extended page access register is
set to 0 before reading clause 45, register 3.1.
The workaround is to set extended page access register to 0 before accessing clause 45, register 3.1.
8.6
8.7
Clause 45 register address post-increment
Clause 45 register address post-increment only works when reading registers and only when extended
page access register (register 31) is set to 0.
The workaround is to access the registers individually.
Fast link failure indication
The fast link failure indication for all the ports is enabled using port 0, register 19E.4.
The workaround is to set register 19E.4 = 1 in PHY 0 to enable Fast Link Fail indication.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
125
Design Considerations
8.8
8.9
Near-end loopback with AMS enabled
Near-end loopback does not work when AMS is enabled. Near-end loopback is controlled by setting bit
14 of register 0.
The workaround is to disable AMS when enabling loopback. This is a debug feature and does not have
any real life implications.
Carrier detect assertion
Carrier detect assertion is set to false incorrectly when 9 out of 10 bits in the K28.1 word are in error.
No real life implication is expected, because the event that can trigger this error is extremely unlikely. If it
does occur, the link may drop momentarily and come back up.
8.10 Link status not correct in register 24E3.2 for 100BASE-
FX operation
The link status in register 24E3.2 only reflects the status of 1000BASE-X links. It does not reflect the
status of 100BASE-FX links.
The workaround is to check register 28.4:3 for media operating mode (10 for fiber), 28.4:3 for speed
status (100 for 100 Mbps), and then check 16.12 for current link status.
8.11 Register 28.14 does not reflect autonegotiation disabled
in 100BASE-FX mode
Register 28.14 does not reflect autonegotiation status in 100BASE-FX mode. It works correctly in all
copper and 1000BASE-X media modes.
The workaround is to use register 0.12 for autonegotiation status in 100BASE-FX mode when AMS is
disabled. For more information about limitations when AMS is enabled, see AMS and 100BASE-FX,
page 125.
8.12 Internal clock disabled when media switches from fiber
to copper with autonegotiation disabled
When the device switches from fiber to copper media when autonegotiation is disabled, an internal clock
may be stuck low causing the device to not pass traffic correctly.
The workaround is to write a value of 0xC040 to register 0 when switching media from fiber to copper.
8.13 Near-end loopback non-functional in protocol transfer
mode
Near-end loopback does not work correctly when the device is configured in protocol transfer mode.
This is a debug feature and does not have any effect on the normal operation of the device.
8.14 Fiber-media recovered clock does not squelch based on
link status
To squelch the clock in fiber media mode, code sync status is used instead of link status. This causes the
clock to not be squelched if the device is configured in 1000BASE-X mode with autonegotiation enabled
when the transmit fiber is unplugged.
There is a software workaround for this issue where the device's internal microcontroller monitors link
status and forces the clock off when no link is present.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
126
Design Considerations
8.15 1000BASE-X parallel detect mode with Clause 37
autonegotiation enabled
When connected to a forced-mode link partner and attempting autonegotiation, the PHY in 1000BASEX
parallel detect mode requires a minimum 250 ms IDLE stream in order to establish a link. If the PHY port
is programmed with 1000BASE-X parallel detect-enabled (MAC-side register 16E3 bit 13, or media-side
register 23E3 bit 13), then a forced-mode link partner sending traffic with an inter-packet gap less than
250 ms will not allow the local device’s PCS to transition from a link-down to link-up state.
8.16 Anomalous PCS error indications in Energy Efficient
Ethernet mode
When a port is processing traffic with Energy Efficient Ethernet enabled on the link, certain PCS errors
(such as false carriers, spurious start-of-stream detection, and idle errors) and EEE wake errors may
occur. There is no effect on traffic bit error rate for cable lengths up to 75 meters, and minor packet loss
may occur on links longer than 75 meters. Regardless of cable length, some error indications should not
be used while EEE is enabled. These error indications include false carrier interrupts (Interrupt Status
register 26 bit 3), receive error interrupts (Interrupt Status register 26 bit 0), and EEE wake error
interrupts.
Contact Microsemi for a script that needs to be applied during system initialization if EEE will be enabled.
VMDS-10402 VSC8504-01 Datasheet Revision 4.2
127
Ordering Information
9
Ordering Information
The VSC8504-01 device is offered with two operating temperature ranges. The range for VSC8504-01 is
0 °C ambient to 125 °C junction, and the range for VSC8504-04 is -40 °C ambient to 125 °C junction.
VSC8504XKS-01 and VSC8504XKS-04 are packaged in a lead(Pb)-free, 256-pin, plastic ball grid array
(BGA) with a 17 mm × 17 mm body size, 1 mm pin pitch, and 1.8 mm maximum height.
Lead(Pb)-free products from Microsemi comply with the temperatures and profiles defined in the joint
IPC and JEDEC standard IPC/JEDEC J-STD-020. For more information, see the IPC and JEDEC
standard.
The following table lists the ordering information for the VSC8504-01 device.
Table 139 • Ordering Information
Part Order Number Description
VSC8504XKS-01
VSC8504XKS-04
Lead-free, 256-pin, plastic BGA with a 17 mm × 17 mm body size, 1 mm
pin pitch, and 1.8 mm maximum height. The operating temperature is 0 °C
ambient to 125 °C junction .
1
Lead-free, 256-pin, plastic BGA with a 17 mm × 17 mm body size, 1 mm
pin pitch, and 1.8 mm maximum height. The operating temperature is
1
–40 °C ambient to 125 °C junction .