Continuity Test Pen Assembly
CONTINUITY
TEST
PEN ASSEMBLY
Application Tooling
Specification Sheet
Order No. 63812-1100
FEATURES
ꢀ Standard 4mm diameter banana receptacle, easily attaches to a continuity tester, or multi-tester (not included)
ꢀ Slip on cover, protects the probe area when not in use.
SCOPE
Products: CTX64, 150 and 280 terminals inserted into CMX< and Euro-6 connector housing assemblies.
CP 0.6, 1.5, 2.8 terminals inserted into CMC, connector housing assemblies.
Connector
Series No.
Description
CMX 70
Connector Housing Assembly Order No.
34820-0111
34820-0121
34821-0111
34821-0121
34820-0112
34820-0122
34821-0112
34821-0122
34820-0113
34820-0123
34821-0113
34821-0123
34820-0114
34820-0124
34821-0114
34821-0124
34820-0115
34820-0125
34821-0115
34821-0125
34820-0116
34820-0126
34821-0116
34821-0126
34820
34821
CMX 120
198009-1001 198009-1002 198009-1003 198009-1004 198009-1011 198009-1013
198009-1021 198009-1023 198009-1031 198009-1033 198009-1041 198009-1043
198009-1051 198009-1053 198009-1061 198009-1063 198009-1071 198009-2001
198009-2002 198009-2003 198009-2004 198009-2011
198009
CMX 53 Way
560065
560065
64318
CMX 55 Way 560065-5511 560065-5512 560065-5521 560065-5521
CMX 65 Way 560065-6511 560065-6512 560065-6521 560065-6521
CMC 28 Way 64318-1011
CMC 24 Way 64319-2211
64318-1018
64319-2218
64319-1216
64319-3219
64320-2319
64320-1318
64320-3319
64321-1018
64326-1002
98833-1032
98833-2033
98833-1042
98833-2043
64318-1019
64319-4211
64319-1218
64318-3011
64319-4218
64319-1219
64318-3018
64319-3211
64318-3019
64319-3216
64319
64320
64319-1211
64319-3218
CMC 32 Way
CMC 36 Way 64320-2311
64320-4311
64320-1319
64320-4319
64320-1350
64320-1311
64320-3311
64321-2018
64326-1009 64326-10010
98833-1035
64320-1315
64321-2019
CMC 48 Way
64320-3318
64321
64326
CMC 53 Way 64321-1011
CMC 22 Way 64326-1001
64321-1019
64326-1005
98833-1033
98833-2034
98833-1043
98833-2044
64321-2011
64326-1006
98833-1034
98833-2035
98833-1044
98833-2045
98833-1031
98833-2032
98833-2031
CMX 32 Way
98833
98833-1041
98833-2042
98833-1045
98833-2041
CMX 48 Way
Doc No: ATS-638121100 Release Date: 10-19-11
Revision: B Revision Date: 11-30-11
UNCONTROLLED COPY
Page 1 of 4
Continuity Test Pen Assembly
OPERATION
1. Connect the 4mm banana receptacle on the
continuity test pen to a continuity tester, or multi-
tester device (not included).
ELECTRICAL
TEST PEN
2. Strip and attach the loose ends of the wire harness
to the continuity tester, or multi-tester device (not
included).
3. Remove the protective cover from the test probe.
See Figure 1.
PROTECTIVE
COVER
PROBE
Figure 1
For CMX Housing Assemblies
1. Gently place the test probe into the test holes provided on the connector housing. See Figure 2.
Figure 2 Connector Housing Diagrams
CTX64
CTX150
CTX280
ACCESS FOR TEST PROBE CAVITY
ACCESS FOR TEST
PROBE CAVITY
0.8mm
ACCESS FOR TEST PROBE
Doc No: ATS-638121100 Release Date: 10-19-11
Revision: B Revision Date: 11-30-11
UNCONTROLLED COPY
Page 2 of 4
Continuity Test Pen Assembly
2. Maintain pen perpendicularity to the connector housing, for correct contact onto the terminals. This will also
prevent damage to the test probe. See Figure 3.
BANANA PLUGGING
AREA
PUT THE TIP OF
THE PROBE IN FRONT
OF THE SPECIFIC
PROBE CAVITY
DO NOT PUT THE PROBE
DIRECTLY INTO THE
TERMINAL CAVITY
Figure 3
Note the operation of the test meter device (not included), and take any necessary action, for test failures.
The continuity test pen is a sealed
unit. Do not try to disassemble the
test pen.
TERMINAL
For CMC Housing Assemblies
1. Link the banana plug to the
back of the electrical test pen.
2. Gently insert the test probe
into the 0.635 terminal cavity
on the connector housing. See
Figure 4.
HOUSING
TEST PROBE
3. Maintain pen perpendicularity
to the connector housing, for
correct contact onto the
terminals. This will also
prevent damage to the test
probe.
Figure 4
Doc No: ATS-638121100 Release Date: 10-19-11
UNCONTROLLED COPY
Page 3 of 4
Revision: B
Revision Date: 11-30-11
Continuity Test Pen Assembly
Maintenance
1. Keep the protective cover on the test pen when not in use.
2. Keep the Electrical Test Pen in a clean, dry place
3. No lubrication or adjustments are required for the Electrical Test Pen
4. Molex does not offer repair parts for the test pen.
Contact Information
For more information on Molex application tooling please contact your nearest Molex location shown below.
http://www.molex.com
Doc No: ATS-638121100 Release Date: 10-19-11
Revision: B Revision Date: 11-30-11
UNCONTROLLED COPY
Page 4 of 4