DC/DC Converter
URE_P-6WR3 & URF_P-6WR3 Series
6W,Ultra wide input isolated & regulated dual/single
output , DIP package, DC/DC converter
FEATURES
Wide input voltage range (4:1)
High efficiency up to 88%
No-load power consumption as low as 0.12W
Isolation voltage :3K VDC
Operating temperature range: -40℃ to +85℃
Input under-voltage protection, output short
circuit , over-current, over-voltage protection
Meet CISPR22/EN55022 CLASS A, without external
components
International standard pin-out
IEC60950,UL60950,EN60950 approval
CB
Patent Protection RoHS
URF_P-6WR3 & URF_P-6WR3 series are isolated 6W DC-DC converters with 4:1 input voltage. They feature efficiency up to 88%, 3000VDC
isolation voltage, operating temperature of -40℃ ~ +85℃, solation voltage of 3000VDC, output over-voltage protection and output short
circuit protection with the bare component in compliance with CISPR22/EN55022 CLASS A; these products are widely used in fields such as
industrial control, electric power, instruments and communication.
Selection Guide
Input Voltage (VDC)
Output
Efficiency
(%,Min./Typ.)
@ Full Load
Max.
②
Capacitive
Certification
Part No.
Nominal
(Range)
Output Current (mA)
①
Max.
Output Voltage (VDC)
③
(Max./Min.)
±600/0
±250/0
±200/0
1500/0
1200/0
667/0
Load (µF)
URE2405P-6WR3
URE2412P-6WR3
URE2415P-6WR3
URF2403P-6WR3
URF2405P-6WR3
URF2409P-6WR3
URF2412P-6WR3
URF2415P-6WR3
URF2424P-6WR3
URF4803P-6WR3
URF4805P-6WR3
URF4812P-6WR3
URF4815P-6WR3
URF4824P-6WR3
±5
±12
±15
3.3
5
78/80
82/84
83/85
77/79
80/82
83/85
84/86
86/88
85/87
77/79
81/83
85/87
86/88
85/87
680
330
220
2200
2200
1000
680
24
40
(9-36)
9
12
15
24
3.3
5
500/0
UL/CE/CB
400/0
680
250/0
680
1500/0
1200/0
500/0
2200
2200
680
48
80
12
15
24
(18-75)
400/0
680
250/0
680
Notes:
1
2
3
The input voltage shoud not exceed the maximun rating, or it maight cause unrecoverable damages;
Efficiency is measured In nominal input voltage and rated output load;
The capacitive loads of positive and negative outputs are identical.
Input Specifications
Item
Operating Conditions
Min.
--
Typ.
261/5
297/5
131/4
146/4
20
Max.
268/8
320/8
134/7
154/7
--
Unit
mA
3.3V output
24VDC Input
48VDC Input
Other output
--
Input Current (full load / no-load)
3.3V output
--
Other output
--
24VDC Input
48VDC Input
24VDC Input
48VDC Input
24VDC Input
48VDC Input
24VDC Input
48VDC Input
--
Reflected Ripple Current
Input impulse Voltage (1sec. max.)
Starting Voltage
mA
--
20
--
-0.7
-0.7
--
--
50
--
100
9
--
VDC
--
--
18
6.5
5.5
14.0
--
under-voltage turn-off
15.5
--
2016.01.11-A/2
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URE_P-6WR3 & URF_P-6WR3 Series
Starting Time
Input Filter
Nominal input& constant resistance load
10
ms
--
--
Pi filter
Unavailable
Hot Plug
Output Specifications
Item
Operating Conditions
5%-100% load
Min.
--
Typ.
Max.
±3
Unit
±1
±1
Output Voltage Accuracy
Single output
Dual output
--
±3
0%-5% load
--
±2
±5
Balance of Output Voltage
Line Regulation
Dual output, balanced load
--
±0.5
±0.2
±1.5
±0.5
Full load, the input voltage is
from low voltage to high
voltage
Positive output
Negative output
Positive output
Negative output
--
%
--
--
--
±0.5
±0.5
±0.5
±1
±1
①
Load Regulation
5%-100% load
±1.5
Dual output, main circuit with 50% load,
auxiliary circuit with 10%-100% load
Cross Regulation
--
--
±5
Transient Recovery Time
--
--
300
±3
500
±5
µs
%
25% load step change
Full load
Transient Response Deviation
%/℃
Temperature Drift Coefficient
--
--
±0.03
②
Ripple&Noise
20MHz bandwidth, 5%-100% load
Input voltage range
--
85
--
120
160
290
190
mV p-p
%Vo
Over-voltage Protection
Over-current Protection
Short circuit Protection
110
110
110
24V output
Input voltage range
Others
220
140
%Io
Input voltage range
Continuous, self-recovery
Note:①When testing from 0% to100%load working conditions,load regulation index of ±5%;
②0%-5% load ripple&Noise is no more than 5%Vo.Ripple and noise are measured by “parallel cable” method, please see DC-DC Converter Application
Notes for specific operation.
General Specifications
Item
Operating Conditions
Min.
Typ.
--
Max.
--
Unit
Input-output, with the test time of 1 minute and the
leak current lower than 1mA
Isolation Voltage
3000
VDC
Isolation Resistance
Isolation Capacitance
Operating Temperature
Storage Temperature
Storage Humidity
Input-output, insulation voltage 500VDC
Input-output, 100KHz/0.1V
1000
--
--
1000
--
--
--
MΩ
pF
Derating if the temperature is
≥71℃(see Fig. 1)
-40
-55
5
85
125
95
℃
--
Non-condensing
--
%RH
Pin Welding Resistance
Temperature
Welding spot is 1.5mm away from the casing, 10
seconds
℃
--
--
300
Vibration
10-55Hz, 10G, 30 Min. along X, Y and Z
Switching Frequency
MTBF
PWM mode
--
300
--
KHz
MIL-HDBK-217F@25℃
1000
--
--
K hours
Note:* This series of products using the technique of reducing frequency. The switching frequency is test at full load; when the load is below 50%, the switching
frequency decreases with decreasing load.
Physical Specifications
Black flame-retardant heat-proof plastic (UL94-V0)
31.60*20.30*10.20 mm
Casing Material
Package Dimensions
Weight
13.00g(Typ.)
Free air convection
Cooling method
2016.01.11-A/2
Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URE_P-6WR3 & URF_P-6WR3 Series
EMC Specifications
CISPR22/EN55022 CLASS A (Bare component)/
CE
CLASS B (see Fig.3-② for recommended circuit)
CISPR22/EN55022 CLASS A (Bare component)/
CLASS B (see Fig.3-② for recommended circuit)
EMI
RE
ESD
RS
IEC/EN61000-4-2 Contact ±4KV
perf. Criteria B
perf. Criteria A
perf. Criteria B
perf. Criteria B
perf. Criteria A
IEC/EN61000-4-3 10V/m
IEC/EN61000-4-4 ±2KV (see Fig.3-① for recommended circuit)
IEC/EN61000-4-5 ±2KV (see Fig.3-①for recommended circuit)
IEC/EN61000-4-6 3 Vr.m.s
EFT
EMS
Surge
CS
Immunities of voltage dip,
drop and short interruption
IEC/EN61000-4-29 0-70%
perf. Criteria B
Product Characteristic Curve
Temperature Derating Curve
120
100
80
60
Safe Operating Area
40
20
0
-40
0
40
71 85
120
Operating Temperature(℃)
Fig. 1
Design Reference
1. Typical application
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery.
If it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or
select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product.
2016.01.11-A/2
Page 3 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URE_P-6WR3 & URF_P-6WR3 Series
Single
+Vo
0V
Vin
Vin(VDC)
Cin(µF)
100
Cout(µF)
Cout
Cin
DC
DC
24
48
10
10
GND
10~47
Dual
+Vo
0V
Vin
Cout
Cout
Cin
DC DC
GND
-Vo
Fig. 2
2. EMC solution-recommended circuit
URE_P-6WR3:
URF_P-6WR3:
CY
1
LCM
FUSE
LDM1
FUSE
V in
Vin
+Vo
V in
Vin
+Vo
+
+
LOAD
DC/DC
DC/DC
C0
C1
C3
C3
C0
C1
C2
MOV
MOV
GND
GND
-Vo
(0V)
GND
0V
GND
①
②
①
②
CY
2
Fig. 3
Notes: Part ① in the Fig. 3 is used for EMS test and part ② for EMI filtering; selected based on needs.
Parameter description
Parameter description
URF_P-6WR3
Vin:24V
Choose according to actual input current
URE_P-6WR3
Vin:24V
Model
Vin:48V
Model
FUSE
MOV
C0
FUSE
MOV
C0
Choose according to actual input current
S20K30
S14K60
S20K30
1000µF/50V
1µF/50V
330µF/50V
2.2µF/50V
330µF/100V
2.2µF/100V
C1,C2
C1
2.2 mH, recommended to use MORNSUN’s
FL2D-30-222
C3
Refer to the Cout in Fig.2
4.7µH
LCM
C3
LDM1
CY1、CY2
Refer to the Cout in Fig.2
1nF/3KV
3. It is not allowed to connect modules output in parallel to enlarge the power
4. For more information please find DC-DC converter application notes on www.mornsun-power.com
2016.01.11-A/2
Page 4 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URE_P-6WR3 & URF_P-6WR3 Series
Dimensions and Recommended Layout
Note:
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com.The
Packing bag number of Horizontal package: 58210008;
2. The max. capacitive load should be tested within the input voltage range and under full load conditions;
3. Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta=25℃, humidity<75%RH when inputting
nominal voltage and outputting rated load;
4. The recommended unbalance degree of the dual output module load is ≤±5%; if the degree exceeds ±5%, the product performance
cannot be guaranteed to comply with all parameters in the datasheet. Please contact our technicians directly for specific information;
5. All index testing methods in this datasheet are based on our Company’s corporate standards;
6. The performance indexes of the product models listed in this datasheet are as above, but some indexes of non-standard model
products will exceed the above-mentioned requirements, and please directly contact our technicians for specific information;
7. We can provide product customization service;
8. Specifications of this product are subject to changes without prior notice.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: isnfo@mornsun.cn
2016.01.11-A/2
Page 5 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
相关型号:
©2020 ICPDF网 联系我们和版权申明