URF2412P-6WR3 [MORNSUN]

DC-DC Regulated Power Supply Module, 1 Output, 6W, Hybrid, DIP-24/7;
URF2412P-6WR3
型号: URF2412P-6WR3
厂家: MORNSUN SCIENCE& TECHNOLOGY LTD.    MORNSUN SCIENCE& TECHNOLOGY LTD.
描述:

DC-DC Regulated Power Supply Module, 1 Output, 6W, Hybrid, DIP-24/7

文件: 总5页 (文件大小:1958K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DC/DC Converter  
URE_P-6WR3 & URF_P-6WR3 Series  
6W,Ultra wide input isolated & regulated dual/single  
output , DIP package, DC/DC converter  
FEATURES  
Wide input voltage range (4:1)  
High efficiency up to 88%  
No-load power consumption as low as 0.12W  
Isolation voltage :3K VDC  
Operating temperature range: -40to +85℃  
Input under-voltage protection, output short  
circuit , over-current, over-voltage protection  
Meet CISPR22/EN55022 CLASS A, without external  
components  
International standard pin-out  
IEC60950,UL60950,EN60950 approval  
CB  
Patent Protection RoHS  
URF_P-6WR3 & URF_P-6WR3 series are isolated 6W DC-DC converters with 4:1 input voltage. They feature efficiency up to 88%, 3000VDC  
isolation voltage, operating temperature of -40~ +85, solation voltage of 3000VDC, output over-voltage protection and output short  
circuit protection with the bare component in compliance with CISPR22/EN55022 CLASS A; these products are widely used in fields such as  
industrial control, electric power, instruments and communication.  
Selection Guide  
Input Voltage (VDC)  
Output  
Efficiency  
(%,Min./Typ.)  
@ Full Load  
Max.  
Capacitive  
Certification  
Part No.  
Nominal  
(Range)  
Output Current (mA)  
Max.  
Output Voltage (VDC)  
(Max./Min.)  
±600/0  
±250/0  
±200/0  
1500/0  
1200/0  
667/0  
Load (µF)  
URE2405P-6WR3  
URE2412P-6WR3  
URE2415P-6WR3  
URF2403P-6WR3  
URF2405P-6WR3  
URF2409P-6WR3  
URF2412P-6WR3  
URF2415P-6WR3  
URF2424P-6WR3  
URF4803P-6WR3  
URF4805P-6WR3  
URF4812P-6WR3  
URF4815P-6WR3  
URF4824P-6WR3  
±5  
±12  
±15  
3.3  
5
78/80  
82/84  
83/85  
77/79  
80/82  
83/85  
84/86  
86/88  
85/87  
77/79  
81/83  
85/87  
86/88  
85/87  
680  
330  
220  
2200  
2200  
1000  
680  
24  
40  
(9-36)  
9
12  
15  
24  
3.3  
5
500/0  
UL/CE/CB  
400/0  
680  
250/0  
680  
1500/0  
1200/0  
500/0  
2200  
2200  
680  
48  
80  
12  
15  
24  
(18-75)  
400/0  
680  
250/0  
680  
Notes  
1
2
3
The input voltage shoud not exceed the maximun rating, or it maight cause unrecoverable damages;  
Efficiency is measured In nominal input voltage and rated output load;  
The capacitive loads of positive and negative outputs are identical.  
Input Specifications  
Item  
Operating Conditions  
Min.  
--  
Typ.  
261/5  
297/5  
131/4  
146/4  
20  
Max.  
268/8  
320/8  
134/7  
154/7  
--  
Unit  
mA  
3.3V output  
24VDC Input  
48VDC Input  
Other output  
--  
Input Current (full load / no-load)  
3.3V output  
--  
Other output  
--  
24VDC Input  
48VDC Input  
24VDC Input  
48VDC Input  
24VDC Input  
48VDC Input  
24VDC Input  
48VDC Input  
--  
Reflected Ripple Current  
Input impulse Voltage (1sec. max.)  
Starting Voltage  
mA  
--  
20  
--  
-0.7  
-0.7  
--  
--  
50  
--  
100  
9
--  
VDC  
--  
--  
18  
6.5  
5.5  
14.0  
--  
under-voltage turn-off  
15.5  
--  
2016.01.11-A/2  
Page 1 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URE_P-6WR3 & URF_P-6WR3 Series  
Starting Time  
Input Filter  
Nominal input& constant resistance load  
10  
ms  
--  
--  
Pi filter  
Unavailable  
Hot Plug  
Output Specifications  
Item  
Operating Conditions  
5%-100% load  
Min.  
--  
Typ.  
Max.  
±3  
Unit  
±1  
±1  
Output Voltage Accuracy  
Single output  
Dual output  
--  
±3  
0%-5% load  
--  
±2  
±5  
Balance of Output Voltage  
Line Regulation  
Dual output, balanced load  
--  
±0.5  
±0.2  
±1.5  
±0.5  
Full load, the input voltage is  
from low voltage to high  
voltage  
Positive output  
Negative output  
Positive output  
Negative output  
--  
%
--  
--  
--  
±0.5  
±0.5  
±0.5  
±1  
±1  
Load Regulation  
5%-100% load  
±1.5  
Dual output, main circuit with 50% load,  
auxiliary circuit with 10%-100% load  
Cross Regulation  
--  
--  
±5  
Transient Recovery Time  
--  
--  
300  
±3  
500  
±5  
µs  
%
25% load step change  
Full load  
Transient Response Deviation  
%/  
Temperature Drift Coefficient  
--  
--  
±0.03  
Ripple&Noise  
20MHz bandwidth, 5%-100% load  
Input voltage range  
--  
85  
--  
120  
160  
290  
190  
mV p-p  
%Vo  
Over-voltage Protection  
Over-current Protection  
Short circuit Protection  
110  
110  
110  
24V output  
Input voltage range  
Others  
220  
140  
%Io  
Input voltage range  
Continuous, self-recovery  
Note:When testing from 0% to100%load working conditionsload regulation index of ±5%;  
0%-5% load ripple&Noise is no more than 5%Vo.Ripple and noise are measured by “parallel cable” method, please see DC-DC Converter Application  
Notes for specific operation.  
General Specifications  
Item  
Operating Conditions  
Min.  
Typ.  
--  
Max.  
--  
Unit  
Input-output, with the test time of 1 minute and the  
leak current lower than 1mA  
Isolation Voltage  
3000  
VDC  
Isolation Resistance  
Isolation Capacitance  
Operating Temperature  
Storage Temperature  
Storage Humidity  
Input-output, insulation voltage 500VDC  
Input-output, 100KHz/0.1V  
1000  
--  
--  
1000  
--  
--  
--  
MΩ  
pF  
Derating if the temperature is  
71(see Fig. 1)  
-40  
-55  
5
85  
125  
95  
--  
Non-condensing  
--  
%RH  
Pin Welding Resistance  
Temperature  
Welding spot is 1.5mm away from the casing, 10  
seconds  
--  
--  
300  
Vibration  
10-55Hz, 10G, 30 Min. along X, Y and Z  
Switching Frequency  
MTBF  
PWM mode  
--  
300  
--  
KHz  
MIL-HDBK-217F@25℃  
1000  
--  
--  
K hours  
Note:* This series of products using the technique of reducing frequency. The switching frequency is test at full load; when the load is below 50%, the switching  
frequency decreases with decreasing load.  
Physical Specifications  
Black flame-retardant heat-proof plastic (UL94-V0)  
31.60*20.30*10.20 mm  
Casing Material  
Package Dimensions  
Weight  
13.00g(Typ.)  
Free air convection  
Cooling method  
2016.01.11-A/2  
Page 2 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URE_P-6WR3 & URF_P-6WR3 Series  
EMC Specifications  
CISPR22/EN55022 CLASS A (Bare component)/  
CE  
CLASS B (see Fig.3-for recommended circuit)  
CISPR22/EN55022 CLASS A (Bare component)/  
CLASS B (see Fig.3-for recommended circuit)  
EMI  
RE  
ESD  
RS  
IEC/EN61000-4-2 Contact ±4KV  
perf. Criteria B  
perf. Criteria A  
perf. Criteria B  
perf. Criteria B  
perf. Criteria A  
IEC/EN61000-4-3 10V/m  
IEC/EN61000-4-4 ±2KV (see Fig.3-for recommended circuit)  
IEC/EN61000-4-5 ±2KV (see Fig.3-for recommended circuit)  
IEC/EN61000-4-6 3 Vr.m.s  
EFT  
EMS  
Surge  
CS  
Immunities of voltage dip,  
drop and short interruption  
IEC/EN61000-4-29 0-70%  
perf. Criteria B  
Product Characteristic Curve  
Temperature Derating Curve  
120  
100  
80  
60  
Safe Operating Area  
40  
20  
0
-40  
0
40  
71 85  
120  
Operating Temperature()  
Fig. 1  
Design Reference  
1. Typical application  
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery.  
If it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or  
select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product.  
2016.01.11-A/2  
Page 3 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URE_P-6WR3 & URF_P-6WR3 Series  
Single  
+Vo  
0V  
Vin  
Vin(VDC)  
Cin(µF)  
100  
Cout(µF)  
Cout  
Cin  
DC  
DC  
24  
48  
10  
10  
GND  
10~47  
Dual  
+Vo  
0V  
Vin  
Cout  
Cout  
Cin  
DC DC  
GND  
-Vo  
Fig. 2  
2. EMC solution-recommended circuit  
URE_P-6WR3:  
URF_P-6WR3:  
CY  
1
LCM  
FUSE  
LDM1  
FUSE  
V in  
Vin  
+Vo  
V in  
Vin  
+Vo  
+
+
LOAD  
DC/DC  
DC/DC  
C0  
C1  
C3  
C3  
C0  
C1  
C2  
MOV  
MOV  
GND  
GND  
-Vo  
(0V)  
GND  
0V  
GND  
CY  
2
Fig. 3  
Notes: Part in the Fig. 3 is used for EMS test and part for EMI filtering; selected based on needs.  
Parameter description  
Parameter description  
URF_P-6WR3  
Vin:24V  
Choose according to actual input current  
URE_P-6WR3  
Vin:24V  
Model  
Vin:48V  
Model  
FUSE  
MOV  
C0  
FUSE  
MOV  
C0  
Choose according to actual input current  
S20K30  
S14K60  
S20K30  
1000µF/50V  
1µF/50V  
330µF/50V  
2.2µF/50V  
330µF/100V  
2.2µF/100V  
C1,C2  
C1  
2.2 mH, recommended to use MORNSUN’s  
FL2D-30-222  
C3  
Refer to the Cout in Fig.2  
4.7µH  
LCM  
C3  
LDM1  
CY1CY2  
Refer to the Cout in Fig.2  
1nF/3KV  
3. It is not allowed to connect modules output in parallel to enlarge the power  
4. For more information please find DC-DC converter application notes on www.mornsun-power.com  
2016.01.11-A/2  
Page 4 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URE_P-6WR3 & URF_P-6WR3 Series  
Dimensions and Recommended Layout  
Note:  
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com.The  
Packing bag number of Horizontal package: 58210008;  
2. The max. capacitive load should be tested within the input voltage range and under full load conditions;  
3. Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta=25, humidity<75%RH when inputting  
nominal voltage and outputting rated load;  
4. The recommended unbalance degree of the dual output module load is ±5%; if the degree exceeds ±5%, the product performance  
cannot be guaranteed to comply with all parameters in the datasheet. Please contact our technicians directly for specific information;  
5. All index testing methods in this datasheet are based on our Company’s corporate standards;  
6. The performance indexes of the product models listed in this datasheet are as above, but some indexes of non-standard model  
products will exceed the above-mentioned requirements, and please directly contact our technicians for specific information;  
7. We can provide product customization service;  
8. Specifications of this product are subject to changes without prior notice.  
Mornsun Guangzhou Science & Technology Co., Ltd.  
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China  
Tel: 86-20-38601850-8801  
Fax: 86-20-38601272  
E-mail: isnfo@mornsun.cn  
2016.01.11-A/2  
Page 5 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  

相关型号:

URF2415LP-10WR3

DC/DC Converter
MORNSUN

URF2415LP-20W

REGULATED SINGLE OUTPUT DC-DC CONVERTER
MORNSUN

URF2415LP-20WR3

DC/DC Converter
MORNSUN

URF2415P-6WR2

SINGLE OUTPUT, DIP PACKAGING, DC-DC CONVERTER
MORNSUN

URF2415P-6WR3

DC/DC Converter
MORNSUN

URF2424LP-10WR3

DC/DC Converter
MORNSUN

URF2424LP-10WR3A2S

DC-DC Regulated Power Supply Module
MORNSUN

URF2424LP-10WR3A4S

DC-DC Regulated Power Supply Module
MORNSUN

URF2424LP-20W

REGULATED SINGLE OUTPUT DC-DC CONVERTER
MORNSUN

URF2424LP-20WR3

DC-DC Regulated Power Supply Module, 1 Output, 19.992W, Hybrid, DIP-6
MORNSUN

URF2424P-6WR2

SINGLE OUTPUT, DIP PACKAGING, DC-DC CONVERTER
MORNSUN

URF2424P-6WR3

DC/DC Converter
MORNSUN