MPM-20SV-15 [MPD]
20W Output Power;型号: | MPM-20SV-15 |
厂家: | MICROPOWER DIRECT, LLC |
描述: | 20W Output Power |
文件: | 总4页 (文件大小:899K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series
MPM-20SV
85 to 305 VAC Input, 20W
Miniature PC Mount
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 20W Output Power
• Universal 85-305 VAC Input
• EN 60950 Approved
• Six Single Output Models
• Meets EN 55022 B
Parameter
Conditions
Min.
85
Typ.
Max.
305
430
63
Units
VAC
VDC
Hz
Input Voltage Range
100
47
Input Frequency
Input Current
See Model Selection Guide
115 VAC
230 VAC
15.0
Inrush Current
A Pk
• >300 kHour MTBF
30.0
0.3
Leakage Current
Output
230 VAC/50 Hz
mA rms
• Compact PC Mount Case
Parameter
Conditions
Min.
Typ.
Max.
Units
Output Voltage
See Model Selection Guide
See Model Selection Guide
Output Current
Output Trim Range
Minimum Load
10
%
0
%
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
2.0
%
VIN = Min to Max
See Note 2
See Note 3
115 VAC
0.5
1.0
50
%
%
100
mV Pk - Pk
15
Hold-Up Time
mSec
%/°C
230 VAC
80
Temperature Coefficient
Short Circuit Protection
Overload Protection
General
0.02
Continuous (Autorecovery)
Autorecovery 110
%
Parameter
Conditions
Min.
Typ.
Max.
Units
VAC
kHz
Input to Output, 60S 3,000
Input to FG, 60S 2,000
Isolation Voltage
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
65
Conditions
Min.
-40
Typ.
+25
Max.
+70
Units
°C
Ambient
-40
+105
°C
Free Air Convection (See Derating Curve)
RH, Non-condensing 95
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Humidity
%
Physical
Case Size
See Mechanical Diagram On Page 4
Case Material
Weight
Non-Conductive Black Plastic (UL94-V0)
4.22 Oz (120g)
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Wave Solder
Min.
300
Typ.
Max.
Units
kHours
260
360
Lead Temperature, See Note 4
°C
Hand Solder
Safety Standards
Safety Class
UL 60950, EN 60950
Class I
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Over Volt. Capacitive
Efficiency
Model
Number
Current (A)
Protection
(VDC)
Load
(µF, Max)
Voltage
(VDC)
Current
(A Max.)
Power
(W)
(%, Typ)
115 VAC
0.60
230 VAC
MPM-20SV-03
MPM-20SV-05
MPM-20SV-09
MPM-20SV-12
MPM-20SV-15
MPM-20SV-24
0.34
0.34
0.34
0.34
0.34
0.34
3.3
5.0
3.50
3.50
2.10
1.60
1.30
0.85
11.5
17.5
20.0
20.0
20.0
20.0
7.5
7.5
48,000
12,240
5,600
5,400
2,400
1,840
75
78
79
83
84
85
0.60
0.60
9.0
12.0
20.0
20.0
30.0
0.60
12.0
15.0
24.0
0.60
0.60
Notes:
5. All units are rated for EN 55022 (CE/RE) class B without
external components.
6. All units are rated for EN 61000-4-4 ( 2 kV) with the addi-
tion of the MOV shown in the typical connection below. They
will meet EN 61000-4-4 ( 4 kV) with the additional input
components shown in the typical connection diagram shown
on page 3.
7. All units are rated for EN 61000-4-5 ( 1 kV/ 2 kV) with the addi-
tion of the MOV shown in the typical connection below. They will
meet EN 61000-4-5 ( 2 kV / 4 kV) with the input components
shown in the typical connection diagram on page 3.
8. It is recommended that a fuse be used on the input of a power
supply for protection. For the MPM-20SV-xx series, a
3.15A/300 VAC slow blow should be used.
1. Operation at no load will not damage the units, however, they
may not meet all specifications.
MPD offers a wide variety of input protection and
filtering modules for use with our AC & DC power
modules. The MACFM-02A may be used with
the MPM-20SV, as shown on page. Full data-
sheets for all our input modules are available on
our website, or call the factory for a more help.
2. Load regulation is measured for an output change of 10% to
100% at nominal input line.
3. When measuring output ripple, it is recommended that an
external 0.1 µF high frequency ceramic capacitor be placed
in parallel with a 47 µF high frequency electrolytic capacitor
from the +VOUT pin to the -VOUT pin.
4. The max lead temp for wave soldering is 5% for a time
period of 5 to 10S. For hand soldering, it is 10% for 3 to 5S.
Typical Connection
The diagram above illustrates a typical application connection of the MPM-20SV series. Notes on this circuit (starting with the input circuit) are:
1. It is recommended that an external fuse and NTC be used. The 5. If output noise levels lower than the specified limits are required,
Model
C1
C2
TVS
recommended fuse is a 3.15A/300 VAC slow blow.
2. All units are rated for EN 55022 (CE/RE) class B without external
components.
3. All units are rated for EN 61000-4-4 ( 2 kV) with the addition of
the MOV shown in the typical connection above. They will meet
the addition of C1 and C2 should be sufficient for most applications.
The recommended values are shown in the table at right. The
output filtering capacitor C2 is a high frequency, low resistance
electrolytic capacitor. Capacitor C1 is ceramic. Voltage derating
of capacitors should be 80% or above.
MPM-20SV-03
MPM-20SV-05
MPM-20SV-09
MPM-20SV-12
MPM-20SV-15
MPM-20SV-24
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
330 µF/10V
330 µF/10V
220 µF/25V
220 µF/25V
220 µF/25V
220 µF/35V
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
EN 61000-4-4 ( 4 kV) with the additional input components 6. TheTVS is added to protect circuits being powered from damage
shown in the typical connection diagram shown on page 3. if the module fails.
4. All units are rated for EN 61000-4-5 ( 1 kV/ 2 kV) with the addi- 7. The trim resistors (R1 & R2) are used to adjust the output voltage
tion of the MOV shown in the typical connection above. They will
meet EN 61000-4-5 ( 2 kV / 4 kV) with the input components
shown in the typical connection diagram on page 3.
level up or down. If this is not required, the trim pin should be
left open. See page 4 for details on using the trim function.
Derating Curve
Input Voltage Vs Load
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
www.micropowerdirect.com
Notes:
Conditions
Criteria
Level
Class B
Class B
8 kV Air
6 kV Contact
10V/m
1. To meet the requirements of EN 61000-
4-4 ( 4 kV), external components are
needed. This can be done discretely (as
shown below), or with the addition of the
MACFM-02A.Contact the factory for more
information.
EN 55022
EN 55022
ESD
RS
EN 61000-4-2
EN 61000-4-3
B
A
B
B
B
B
A
A
B
2. To meet the requirements of EN 61000-4-5
( 2 kV/ 4 kV ), external components are
needed. This can be done discretely (as
shown below), or with the addition of the
MACFM-02A. Contact the factory for more
information.
2 kV
4 kV
1 kV/ 2 kV
2 kV/ 4 kV
10V rms
10A/m
EFT
EN 61000-4-4
EN 61000-4-5
See Note 1
Surge
See Note 2
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
CS
PFM
Voltage Dips, Short, Interruptions
0% - 70%
Typical Connection: With Input Protection/Filtering Components
The diagram above illustrates a typical connection of the MPM-20SV series. 5. Suggested component values are:
The input components are required to meet the more stringent EFT/Surge levels
of EN 61000-4 (see notes for EMC Characteristics table above). Some notes on
these components are:
Component
Fuse
MPM20SV-03 MPM20SV-05 MPM20SV-09 MPM20SV-12 MPM20SV-15 MPM20SV-24
3.15A/300 VAC 3.15A/300 VAC 3.15A/300 VAC 3.15A/300 VAC 3.15A/300 VAC 3.15A/300 VAC
MOV
CX
LDM
LCM
S14K350
0.1 µF/310V
4.7 µH/2A
10 mH
S14K350
0.1 µF/310V
4.7 µH/2A
10 mH
S14K350
0.1 µF/310V
4.7 µH/2A
10 mH
S14K350
0.1 µF/310V
4.7 µH/2A
10 mH
S14K350
0.1 µF/310V
4.7 µH/2A
10 mH
S14K350
0.1 µF/310V
4.7 µH/2A
10 mH
1. It is recommended that an external fuse be used. The recommended fuse
size is a 3.15A/300 VAC slow blow.
2. An external MOV is recommended on the input to protect the unit in the event
of a surge. A recommended value is given in the table at right.
3. The output filtering capacitors (C1 & C2) will reduce the output noise below
specified levels. Recommended values are given in the table on page 2.
4. TheTVS is added to protect circuits being powered from damage if the module
fails. A recommended value for each model is given in the table on page 2.
1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC
CY1/CY2
6. Input protection and filtering modules are available for a number of MPDAC/DC power supplies. For use with the MPM-20SV product series,
the MACFM-02A filter module is recommended. A typical connection diagram and board layout with this module is shown in the figures
below. For pricing or full technical information on the MACFM-02A (or any of our other modules) please contact the factory.
Typical Board Layout: With External Filter Module
Typical Board Layout: With External Filter Module
1. The width of circuit traces should be a minimum of 3 mm.
2. The distance between traces should be a minimum of 6 mm.
3. The distance between a trace and ground should be a minimum of 6 mm.
MicroPower Direct
• 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
External Trim
If not used, the Trim pin should be left open. Please contact the factory for more information.
www.micropowerdirect.com
External Trim Notes:
An external resistor can be used to adjust the converter
output up or down by about 10%. The connection is shown
in the diagram at left. The required resistor value is
calculated by the formulas:
A $ R2
V
REF
=
=
=
-
Trim UP RTRIM
R3 Where A
$R1
REF
-
-
V
R2
A
VTRIM
-
VTRIM V
REF
A $ R1
REF
=
=
=
-
Trim Down RTRIM
R3 Where A
$R2
-
R1
A
V
Where:
RTRIM = The value of the external trim
resistor
VTRIM = The amount of voltage
adjustment required
The values for R1, R2, R3 and VREF are given in
the table below.
Output Voltage (VDC)
3.3
5.0
9.0
12
15
24
R1
R2
3.30 k⍀
1.98 k⍀
1.00 k⍀
1.24 V
3.30 k⍀
3.30 k⍀
1.00 k⍀
2.50 V
7.50 k⍀
2.87 k⍀
1.00 k⍀
2.50 V
3.83 k⍀
1.00 k⍀
1.00 k⍀
2.50 V
7.50 k⍀
1.50 k⍀
1.00 k⍀
2.50 V
8.66 k⍀
1.00 k⍀
1.00 k⍀
2.50 V
R3
VREF
Mechanical Dimensions
Pin Connections
Pin
Function
AC-Ground
AC-Neutral
AC-Line
1
2
3
4
-VOUT
8
+VOUT
Trim
VOUT Trim
Notes:
•
•
All dimensions are typical in inches (mm)
Tolerance x.xx = 0.02 ( 0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com