Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
• 30W Output Power
• Universal 85-265 VAC Input
• EN60950 Approved
Conditions
Min.
85
47
Typ.
Max.
265
440
Units
VAC
Hz
• Single, Dual & Triple Outputs
• Meets EN55022 B
• Meets IEC Safety Class II
See Model Selection Guide
115 VAC
230 VAC
20.0
40.0
Inrush Current
A Pk
• Chassis Mount Case
EMI
Meets CISPR Pub. 22/FCC Class B
115 VAC
230 VAC
0.1
0.3
Safety Ground Leakage Current
mA
DIN Rail Mounting
Kit Available!
Output
Parameter
Conditions
Min.
Typ.
Max.
Units
Output Voltage
Output Current
See Model Selection Guide
See Model Selection Guide
Output Voltage Accuracy, Note 1
Line Regulation
Load Regulation, Single Output
Load Regulation, Dual Output
Load Regulation, Triple Output - Primary
Load Regulation, Triple Output - Aux.
1.0
2.0
1.0
1.0
5.0
5.0
%
%
%
%
%
%
VIN = Min to Max
IO = Min to Max
IO = Min to Max
IO = Min to Max
IO = Min to Max
3.3 & 5.0 VDC Output
All Other Outputs
115 VAC, 60 Hz
0.2
0.5
2.5
2.5
4.0
1.5
1.0
20
1.8
1.3
Ripple & Noise (20 MHz)
%VP-P of VO
Hold-Up Time
mSec
%/°C
% of VO
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, Note 4
Overload Protection, Note 5
General
0.02
120
Zener Diode Clamp
Continuous (Autorecovery)
Typ. 120% to 180% of Output Power
Parameter
Conditions
Input to Output 3,000
Input to Output, Flash Tested For 60S 4,700
Min.
Typ.
Max.
Units
VAC
VAC
MΩ
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
EMI/RFI
500 VDC
Conducted
100
EN 55022 Level B
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
IEC/EN 61000-4-2 Level B
IEC/EN61000-4-3
IEC/EN 61000-4-4 Level 3 2 kV
EMC Compliance
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Surge IEC/EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
100
kHz
Conditions
Min.
-25
Typ.
+25
Max.
+71
Units
°C
Ambient
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
-40
+85
°C
Free Air Convection (See Derating Curve)
RH, Non-condensing 95
Humidity
Physical
%
Case Size, Chassis Mount
Case Size, DIN Rail Option
Case Material
4.41 x 2.51 x 1.01 Inches (112.0 x 63.8 x 25.6 mm)
4.41 x 2.51 x 1.44 Inches (112.0 x 63.8 x 36.6 mm)
Non-Conductive Plastic& Fiberglass (UL94-V0)
6.72 Oz (191g)
Weight
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
250
kHours
Safety Standards
Safety Approvals
Safety Class
IEN 60950, IEC 60950
IEN 60950, IEC 60950
IEC 61140 Class II
Model Selection Guide
Input
Output 1 (Vout 1)
Current (A)
Output 2 (Vout 2)
Current (A)
Output 3 (Vout 3)
Current (A)
Capacitive
Load
(µF, Max)
Model
Current (A)
Efficiency
(%, Typ)
Voltage
Voltage
Voltage
Number
(VDC)
(VDC)
(VDC)
115 VAC 230 VAC
Max.
Min.
Max.
Min.
Max.
Min.
MPM-30S-05CM
MPM-30S-12CM
MPM-30S-15CM
MPM-30S-24CM
MPM-30S-48CM
MPM-30D-12CM
MPM-30D-15CM
MPM-30T-0512CM
0.557
0.543
0.543
0.543
0.543
0.565
0.543
0.572
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
5.0
6.000
2.500
2.000
1.250
0.625
0.600
0.250
0.200
0.125
0.063
8,000
3,900
3,900
1,500
1,000
1,500
1,500
78
80
80
80
80
80
80
76
76
76
71
71
12.0
15.0
24.0
48.0
+12.0 +1.300 +0.130
+15.0 +1.000 +0.100
-12.0 -1.300 -0.130
-15.0 -1.000 -0.100
+12.0 +0.600 +0.120
+12.0 +1.000 +0.200
+15.0 +0.500 +0.050
+3.3 +1.000 +0.220
+5.0 +1.500 +0.300
5.0
5.0
5.0
5.0
3.3
3.000 +0.600
3.000 +0.600
3.000 +0.300
4.500 +0.900
4.000 +0.800
-12.0 -0.600 -0.120 See Note 6
-12.0 -0.250 -0.050 See Note 6
-15.0 -0.500 -0.050 See Note 6
+12.0 +0.250 +0.050 See Note 6
+12.0 +0.250 +0.050 See Note 6
MPM-30T-0512CMA 0.572
MPM-30T-0515CM
MPM-30T-5312CM
MPM-30T-3512CM
0.572
0.588
0.483
Other output combinations are available
Contact the factory for details at:
sales@micropowerdirect.com
Derating Curve
Notes:
1. For triple output models, the output voltage accuracy of the auxilliary outputs
is typically 4%.
2. Load regulation is measured for an output change of 0% to 100% at nominal
input line. For multiple output models, the loads are balanced.
3. Operation at no-load will not damage these units. However, they may not
meet all specifications.
4. Output short circuit protection is provided by a “hiccup mode” circuit. The
unit recovers automatically when the fault condition is removed.
5. Output overload protection is provided by a fold back current limiting
circuit.
6. For triple output models, the maximum capacitive load for 5 VDC and 3.3VDC
outputs is 2,200 µF. For all other outputs it is 1,500 µF.
7. The MPM-30CM series includes a built-in 3.5A/250 VAC fuse. It is recom-
mended that an external 1.5A slow blow fuse also be used on the input for
protection.
Mechanical Dimensions, Chassis Mount
Pin Connections
Pin
Single
Dual
Triple
1
2
3
4
5
6
7
AC-Neutral
AC-Line
+Vo
NC
Common
NC
+Vo
NC
-Vo
NC
+Vo 2
+Vo 1
Common 2/3
-Vo 1
NC
-Vo
+Vo 3
NC = No Connection
A DIN Rail mounting kit is available
Contact the factory for details at:
sales@micropowerdirect.com
Notes:
All dimensions are typical in inches (mm)
MicroPower Direct Tolerance x.xx = 0.01 ( 0.25)
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
©2020 ICPDF网 联系我们和版权申明