Electrical Specifications  
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Key Features:  
Input  
Parameter  
Input Voltage Range  
Input Frequency  
Input Current  
30W Output Power  
Universal 85-265 VAC Input  
EN60950 Approved  
Conditions  
Min.  
85  
47  
Typ.  
Max.  
265  
440  
Units  
VAC  
Hz  
Single, Dual & Triple Outputs  
Meets EN55022 B  
Meets IEC Safety Class II  
See Model Selection Guide  
115 VAC  
230 VAC  
20.0  
40.0  
Inrush Current  
A Pk  
Chassis Mount Case  
EMI  
Meets CISPR Pub. 22/FCC Class B  
115 VAC  
230 VAC  
0.1  
0.3  
Safety Ground Leakage Current  
mA  
DIN Rail Mounting  
Kit Available!  
Output  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
Output Voltage  
Output Current  
See Model Selection Guide  
See Model Selection Guide  
Output Voltage Accuracy, Note 1  
Line Regulation  
Load Regulation, Single Output  
Load Regulation, Dual Output  
Load Regulation, Triple Output - Primary  
Load Regulation, Triple Output - Aux.  
1.0  
2.0  
1.0  
1.0  
5.0  
5.0  
%
%
%
%
%
%
VIN = Min to Max  
IO = Min to Max  
IO = Min to Max  
IO = Min to Max  
IO = Min to Max  
3.3 & 5.0 VDC Output  
All Other Outputs  
115 VAC, 60 Hz  
0.2  
0.5  
2.5  
2.5  
4.0  
1.5  
1.0  
20  
1.8  
1.3  
Ripple & Noise (20 MHz)  
%VP-P of VO  
Hold-Up Time  
mSec  
%/°C  
% of VO  
Temperature Coefficient  
Over Voltage Protection  
Short Circuit Protection, Note 4  
Overload Protection, Note 5  
General  
0.02  
120  
Zener Diode Clamp  
Continuous (Autorecovery)  
Typ. 120% to 180% of Output Power  
Parameter  
Conditions  
Input to Output 3,000  
Input to Output, Flash Tested For 60S 4,700  
Min.  
Typ.  
Max.  
Units  
VAC  
VAC  
MΩ  
Isolation Voltage  
Isolation Test Voltage  
Isolation Resistance  
EMI/RFI  
500 VDC  
Conducted  
100  
EN 55022 Level B  
Electrostatic Discharge (ESD)  
RF Field Susceptibility  
Electrical Fast Transients/Bursts On Mains  
IEC/EN 61000-4-2 Level B  
IEC/EN61000-4-3  
IEC/EN 61000-4-4 Level 3 2 kV  
EMC Compliance  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Surge IEC/EN 61000-4-5 Level 3 1kV/2 kV  
Switching Frequency  
Environmental  
Parameter  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
100  
kHz  
Conditions  
Min.  
-25  
Typ.  
+25  
Max.  
+71  
Units  
°C  
Ambient  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
-40  
+85  
°C  
Free Air Convection (See Derating Curve)  
RH, Non-condensing 95  
Humidity  
Physical  
%
Case Size, Chassis Mount  
Case Size, DIN Rail Option  
Case Material  
4.41 x 2.51 x 1.01 Inches (112.0 x 63.8 x 25.6 mm)  
4.41 x 2.51 x 1.44 Inches (112.0 x 63.8 x 36.6 mm)  
Non-Conductive Plastic& Fiberglass (UL94-V0)  
6.72 Oz (191g)  
Weight  
Reliability Specifications  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
MTBF  
MIL HDBK 217F, 25°C, Gnd Benign  
250  
kHours  
Safety Standards  
Safety Approvals  
Safety Class  
IEN 60950, IEC 60950  
IEN 60950, IEC 60950  
IEC 61140 Class II  
Model Selection Guide  
Input  
Output 1 (Vout 1)  
Current (A)  
Output 2 (Vout 2)  
Current (A)  
Output 3 (Vout 3)  
Current (A)  
Capacitive  
Load  
(µF, Max)  
Model  
Current (A)  
Efficiency  
(%, Typ)  
Voltage  
Voltage  
Voltage  
Number  
(VDC)  
(VDC)  
(VDC)  
115 VAC 230 VAC  
Max.  
Min.  
Max.  
Min.  
Max.  
Min.  
MPM-30S-05CM  
MPM-30S-12CM  
MPM-30S-15CM  
MPM-30S-24CM  
MPM-30S-48CM  
MPM-30D-12CM  
MPM-30D-15CM  
MPM-30T-0512CM  
0.557  
0.543  
0.543  
0.543  
0.543  
0.565  
0.543  
0.572  
0.14  
0.14  
0.14  
0.14  
0.14  
0.14  
0.14  
0.14  
0.14  
5.0  
6.000  
2.500  
2.000  
1.250  
0.625  
0.600  
0.250  
0.200  
0.125  
0.063  
8,000  
3,900  
3,900  
1,500  
1,000  
1,500  
1,500  
78  
80  
80  
80  
80  
80  
80  
76  
76  
76  
71  
71  
12.0  
15.0  
24.0  
48.0  
+12.0 +1.300 +0.130  
+15.0 +1.000 +0.100  
-12.0 -1.300 -0.130  
-15.0 -1.000 -0.100  
+12.0 +0.600 +0.120  
+12.0 +1.000 +0.200  
+15.0 +0.500 +0.050  
+3.3 +1.000 +0.220  
+5.0 +1.500 +0.300  
5.0  
5.0  
5.0  
5.0  
3.3  
3.000 +0.600  
3.000 +0.600  
3.000 +0.300  
4.500 +0.900  
4.000 +0.800  
-12.0 -0.600 -0.120 See Note 6  
-12.0 -0.250 -0.050 See Note 6  
-15.0 -0.500 -0.050 See Note 6  
+12.0 +0.250 +0.050 See Note 6  
+12.0 +0.250 +0.050 See Note 6  
MPM-30T-0512CMA 0.572  
MPM-30T-0515CM  
MPM-30T-5312CM  
MPM-30T-3512CM  
0.572  
0.588  
0.483  
Other output combinations are available  
Contact the factory for details at:  
sales@micropowerdirect.com  
Derating Curve  
Notes:  
1. For triple output models, the output voltage accuracy of the auxilliary outputs  
is typically 4%.  
2. Load regulation is measured for an output change of 0% to 100% at nominal  
input line. For multiple output models, the loads are balanced.  
3. Operation at no-load will not damage these units. However, they may not  
meet all specifications.  
4. Output short circuit protection is provided by a “hiccup mode” circuit. The  
unit recovers automatically when the fault condition is removed.  
5. Output overload protection is provided by a fold back current limiting  
circuit.  
6. For triple output models, the maximum capacitive load for 5 VDC and 3.3VDC  
outputs is 2,200 µF. For all other outputs it is 1,500 µF.  
7. The MPM-30CM series includes a built-in 3.5A/250 VAC fuse. It is recom-  
mended that an external 1.5A slow blow fuse also be used on the input for  
protection.  
Mechanical Dimensions, Chassis Mount  
Pin Connections  
Pin  
Single  
Dual  
Triple  
1
2
3
4
5
6
7
AC-Neutral  
AC-Line  
+Vo  
NC  
Common  
NC  
+Vo  
NC  
-Vo  
NC  
+Vo 2  
+Vo 1  
Common 2/3  
-Vo 1  
NC  
-Vo  
+Vo 3  
NC = No Connection  
A DIN Rail mounting kit is available  
Contact the factory for details at:  
sales@micropowerdirect.com  
Notes:  
All dimensions are typical in inches (mm)  
MicroPower Direct
Tolerance x.xx = 0.01 ( 0.25)  
www.micropowerdirect.com  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MPM-30T-0515IS

Board Mount, 30W Single, Dual & Triple Out AC/DC Power Supplies
MPD

MPM-30T-3512CM

Chassis Mount, 30W Single, Dual & Triple Out AC/DC Power Supplies
MPD

MPM-30T-3512IS

Board Mount, 30W Single, Dual & Triple Out AC/DC Power Supplies
MPD

MPM-30T-5312CM

Chassis Mount, 30W Single, Dual & Triple Out AC/DC Power Supplies
MPD

MPM-30T-5312IS

Board Mount, 30W Single, Dual & Triple Out AC/DC Power Supplies
MPD

MPM-40

Board Mount, 40W Single, Dual & Triple Out AC/DC Power Supplies
MPD

MPM-40D-05

Board Mount, 40W Single, Dual & Triple Out AC/DC Power Supplies
MPD

MPM-40D-0512

Board Mount, 40W Single, Dual & Triple Out AC/DC Power Supplies
MPD

MPM-40D-0524

Board Mount, 40W Single, Dual & Triple Out AC/DC Power Supplies
MPD

MPM-40D-12

Board Mount, 40W Single, Dual & Triple Out AC/DC Power Supplies
MPD

MPM-40D-15

Board Mount, 40W Single, Dual & Triple Out AC/DC Power Supplies
MPD

MPM-40M

40W Output Power
MPD