R3-GGLMP [MSYSTEM]

Remote I/O R3 Series INTERFACE I/O MODULE;
R3-GGLMP
型号: R3-GGLMP
厂家: M-SYSTEM    M-SYSTEM
描述:

Remote I/O R3 Series INTERFACE I/O MODULE

文件: 总10页 (文件大小:205K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: R3-GSLMP1  
/C02: Polyurethane coating  
Remote I/O R3 Series  
/C03: Rubber coating  
INTERFACE I/O MODULE  
(For SLMP Client)  
RELATED PRODUCTS  
• PC configurator software (model: R3CON version 2.55 or  
Functions & Features  
later)  
• Serves as a gateway for allowing data of SLMP-compatible  
devices to be handled by Network module that uses a  
different protocol.  
Downloadable at M-System’s web site.  
A dedicated cable is required to connect the module to the  
PC. Please refer to the internet software download site or  
the users manual for the PC configurator for applicable  
cable types.  
• Reads/writes data from/to the SLMP server.  
• Recognized as analog and/or discrete I/O modules by  
Network module according to the device configuration.  
Typical Applications  
GENERAL SPECIFICATIONS  
Connection  
• A gateway between SLMP and CC-Link.  
Ethernet: RJ-45 Modular Jack  
Internal bus: Via the Installation Base (model: R3-BSx)  
Internal power: Via the Installation Base (model: R3-BSx)  
RUN contact output: M3 separable screw terminal  
(torque 0.5 N·m)  
27.5 [1.08]  
130  
[5.12]  
Screw terminal: Nickel-plated steel  
Isolation: Ethernet to internal bus or internal power to RUN  
contact output  
RUN indicator: Bi-color (green/red) LED  
Green turns ON when SLMP communication is normal and  
fieldbus communication on the R3 Network module side is  
also normal; or  
109  
[4.29]  
mm [inch]  
Red turns ON when receiving data.  
MODEL: R3-GSLMP1S[1]  
(Indication selectable with DIP SW3-4.)  
ERR indicator: Bi-color (green/red) LED  
Green turns ON/blinks in communication errors (OFF with  
wire breakdown; Green blinks with setting errors); or  
Red turns ON when transmitting data.  
(Indication selectable with DIP SW3-4.)  
RUN CONTACT OUTPUT  
ORDERING INFORMATION  
• Code number: R3-GSLMP1S[1]  
Specify a code from below for [1].  
(e.g. R3-GSLMP1S/CE/Q)  
• Specify the specification for option code /Q  
(e.g. /C01)  
RUN contact: Turns on while the green RUN LED is ON (only  
when SLMP communication is normal and fieldbus  
communication on the R3 Network module side is also  
normal).  
COMMUNICATION MODE  
S: Single  
Rated load: 250 V AC @ 0.5 A (cos ø = 1)  
30 V DC @ 0.5 A (resistive load)  
(Less than 50 V AC to conform with EU Directive)  
Maximum switching voltage: 250 V AC or 30 V DC  
Maximum switching power: 250 VA (AC) or 150 W (DC)  
Minimum load: 1 V DC @ 1 mA  
[1] OPTIONS (multiple selections)  
Standards & Approvals  
blank: Without CE  
/CE: CE marking  
Mechanical life: 2 × 10 cycles (300 cycles/min.)  
7
Other Options  
When driving an inductive load, external contact protection  
and noise quenching are recommended.  
blank: none  
/Q: Option other than the above (specify the specification)  
ETHERNET COMMUNICATION  
Communication Standard: IEEE 802.3u  
Transmission: 10BASE-T, 100BASE-TX  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
R3-GSLMP1 SPECIFICATIONS  
ES-8275 Rev.2 Page 1/10  
https://www.m-system.co.jp/  
MODEL: R3-GSLMP1  
Baud rate: 10/100 Mbps (Auto Negotiation function)  
Protocol: SLMP  
Data: Binary  
Max. number of socket connections: 1  
Max. number of communication entries: 16  
Max. number of I/O signals: 128 points (total of analog and  
discrete signals)  
Transmission media: 10BASE-T (STP, Category 5), 100BASE-  
TX (STP, Category 5e)  
Max. number of virtual I/O modules: 16  
Ethernet indicator LED: LINK, DPLX, LINK10, LINK100, COL  
Max. length of fieldbus segment: 100 meters  
IP address: 192.168.0.1 (factory setting);  
Selectable with PC Configurator Software (model: R3CON)  
Connectable devices: MELSEC iQ-R series, MELSEC iQ-F  
series, MELSEC Q series  
INSTALLATION  
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: Installation Base (model: R3-BSx)  
Weight: 200 g (0.44 lb)  
PERFORMANCE  
Data Allocation (No. of Occupied Data Areas)  
Virtual AI module: 16  
Virtual AO module: 16  
Virtual DI module: 1  
Virtual DO module: 1  
Current consumption: 100 mA  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @ 1 minute  
(Ethernet to internal bus or internal power to RUN contact  
output)  
2000 V AC @ 1 minute (power input to FG; isolated on the  
power supply module)  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
RoHS Directive  
R3-GSLMP1 SPECIFICATIONS  
ES-8275 Rev.2 Page 2/10  
https://www.m-system.co.jp/  
MODEL: R3-GSLMP1  
EXTERNAL VIEW  
FRONT VIEW  
SIDE VIEW  
C
4
C
Rotary SW (unused)  
4
RUN LED  
ERR LED  
Rotary SW (unused)  
Ethernet Indicator  
Functions  
Configuration Jack  
RJ-45 Modular Jack  
SW3  
LED  
LINK  
4
Fuinction  
DPLX (Duplex)  
LINK10 (10Mbps)  
3
2
1
1
2
3
ON  
LINK100 (100Mbps)  
COL (Collision)  
4
5
6
R3-GSLMP1 SPECIFICATIONS  
ES-8275 Rev.2 Page 3/10  
https://www.m-system.co.jp/  
MODEL: R3-GSLMP1  
TRANSMISSION DATA DESCRIPTIONS  
R3-GSLMP1 reads/writes data from/in devices in SLMP-compatible CPU of Mitsubishi programmable controller MELSEC using  
SLMP. Devices from/in which data is read/written and addresses using SLMP are set on R3CON.  
Mount the R3-GSLMP1 on the R3 base. Virtual input module sends the data read from SLMP server to the host PLC as an input  
data via R3 Interface module. Two signal types; AI (analog input) and DI (digital input) are available as virtual input module. Flow  
of the signal is as following.  
R3  
SLMP Server  
R3-GSLMP1  
R3 Base  
PLC  
Interface Module  
Virtual output module writes in the data written to the R3 Interface module from the host PLC, to the SLMP server.  
Two signal types; AO (analog output) and DO (digital output) are available as virtual output module. Flow of the signal is as  
following.  
R3  
SLMP Server  
R3-GSLMP1  
R3 Base  
PLC  
Interface Module  
To read/write data from/in devices, 4 types of I/O are available. Refer to the following table.  
I/O TYPE:  
·
READ/WRITE TRANSMITTING POINTS per MODULE DATA ALLOCATION MODE  
VIRTUAL I/O MODULE TYPE  
Virtual input module  
AI (Analog input)  
DI (Digital input)  
Read  
Read  
Write  
Write  
16 points max.  
16 points max.  
16 points max.  
16 points max.  
16  
1
Virtual input module  
AO (Analog output)  
DO (Analog output)  
16  
1
Virtual output module  
Virtual output module  
The devices of the SLMP server are allocated to the virtual input module and the virtual output module of the R3-GSLMP1 by  
setting the R3-GSLPM1’s I/O type, number of channels, device type and device address with R3CON.  
Device Address: Begin address of read/write device (specify with hexadecimal or decimal)  
·
Channel Number: 1 - 16 (Specify the number of data to read/write from begin address)  
·
R3-GSLMP1 SPECIFICATIONS  
ES-8275 Rev.2 Page 4/10  
https://www.m-system.co.jp/  
MODEL: R3-GSLMP1  
· Device: Commands to read from/write in the device (Refer to the following table for available device types)  
AVAILABLE DEVICE TYPES  
AI / AO 32 bit  
SD: Special Register  
D: Data Register  
AI / AO 16 bit  
SD: Special Register  
D: Data Register  
DI / DO 32 bit  
SM: Special relay  
DI / DO 16 bit  
SM: Special relay  
X: Input  
X: Input  
W: Link Register  
W: Link Register  
Y: Output  
Y: Output  
TN: Timer, Current value  
STN: Retentive timer, Current value  
CN: Counter, Current value  
SW, Link special Register  
Z: Index Register  
TN: Timer, Current value  
STN: Retentive timer, Current value  
CN: Counter, Current value  
SW, Link special Register  
Z: Index Register  
M: Internal relay  
L: Latch relay  
F: Annunciator  
V: Edge relay  
B: Link relay  
M: Internal relay  
L: Latch relay  
F: Annunciator  
V: Edge relay  
B: Link relay  
R: File Register  
R: File Register  
S: STEP RELAY  
TS: Timer, Contact  
TC: Timer, Coil  
----  
----  
ZR: File Register  
ZR: File Register  
TS: Timer, Contact  
RD: Module refresh Register  
TC: Timer, Coil  
----  
LTS: Long timer, Contact  
LTC: Long timer, Coil  
----  
STS: Retentive timer, Contact  
STC: Retentive timer, Coil  
LSTS: Long retentive timer, Contact  
LSTC: Long retentive timer, Coil  
CS: Counter, Contact  
STS: Retentive timer, Contact  
STC: Retentive timer, Coil  
----  
----  
CS: Counter, Contact  
CC: Counter, Coil  
LCS: Long counter, Contact  
LCC: Long counter, Coil  
SB: Link special relay  
CC: Counter, Coil  
LCS: Long counter, Contact  
LCC: Long counter, Coil  
SB: Link special relay  
Max. 16 points of analog input/output and max. 16 points of digital input/output can be allocated per a virtual module. Set the data  
allocation to 16 for the slot with the virtual analog input/output module, and set 1 for the slot with virtual digital input/output module by data  
allocation mode of the R3 Interface module.  
Note: Numbers of transmittable data is limited by number of channel and virtual module. R3-GSLMP1 can transmitted max. 128 channels  
or 16 virtual modules. Even though the total number of channels is less than 128, if the total number of virtual modules is 16,  
number of channel cannot be increased.  
Do not mount any modules in the slots which are occupied by virtual modules. If a real I/O module is mounted in the slot, an internal  
bus error occurs and the ERR LED turns on. Max. 16 real I/O modules and virtual modules are available. The R3 interface module  
can not read the data for more than 16 modules.  
Details are explained in Number of the modules and the address allocationon the next page.  
R3-GSLMP1 SPECIFICATIONS  
ES-8275 Rev.2 Page 5/10  
https://www.m-system.co.jp/  
MODEL: R3-GSLMP1  
NUMBER of the MODULES and the ADDRESS ALLOCATION  
· DEVICE CONFIGURATION EXAMPLE 1  
Device setting  
I/O TYPE  
CH. NO.  
SLMP DEVICE  
DEVICE ADDRESS  
AI  
AI  
AI  
AI  
AI  
2
4
SD  
D
0x000  
0x000  
0x000  
0x000  
0x000  
8
W
3
TN  
SW  
10  
· Virtual I/O modules configuration  
Slot No.  
1
2
Virtual AI Virtual AI  
module 1 module 2  
Data Allocation 16  
16  
· Data configuration  
VIRTUAL AI MODULE 1  
VIRTUAL AI MODULE 2  
CH  
ADDRESS  
ADDRESS  
(SLOT NO.1)  
SD 000  
SD 001  
D 000  
(SLOT NO.2)  
TN 002  
SW 000  
SW 001  
SW 002  
SW 003  
SW 004  
SW 005  
SW 006  
SW 007  
SW 008  
SW 009  
1
2
n+0  
n+1  
n+16  
n+17  
n+18  
n+19  
n+20  
n+21  
n+22  
n+23  
n+24  
n+25  
n+26  
n+27  
n+28  
n+29  
n+30  
n+31  
3
n+2  
4
n+3  
D 001  
5
n+4  
D 002  
6
n+5  
D 003  
7
n+6  
W 000  
W 001  
W 002  
W 003  
W 004  
W 005  
W 006  
W 007  
TN 000  
TN 001  
8
n+7  
9
n+8  
10  
11  
12  
13  
14  
15  
16  
n+9  
n+10  
n+11  
n+12  
n+13  
n+14  
n+15  
In this example, total numbers of channles are 20 and uses 2 virtual AI modules. Real I/O modules are mounted on Slots No. 1 and  
2, however, the network module (R3-NC3) recognizes that each of Slots No. 1 to 3 is occupied. That is, R3-NC3 recognizes R3-SV4  
mounted on Slot No.1 as it is and recognizes R3-GSLMP1 mounted on Slot No.2 as divided into two modules and occupying Slots  
No. 2 and 3.  
R3-BS06  
SLOT  
REAL MODULE VIRTUAL MODULE DATA ALLOCATION NO. OF WORDS  
R3-  
SV4  
R3  
-
R3-  
NC3  
R3-  
PS1  
Slot No. 1 R3-SV4  
Slot No. 2 R3-GSLMP1  
Slot No. 3 No module  
Slot No. 4 No module  
Slot No. 5 R3-NC3  
Slot No. 6 R3-PS1  
4
4 words  
GSLMP1  
R3-GSLMP1 (1/2)  
16  
16  
16 words  
R3-GSLMP1 (2/2)  
16 words  
1
2
3
4
5
6
R3-GSLMP1 SPECIFICATIONS  
ES-8275 Rev.2 Page 6/10  
https://www.m-system.co.jp/  
MODEL: R3-GSLMP1  
· DEVICE CONFIGURATION EXAMPLE 2  
Device setting  
I/O TYPE  
CH. NO.  
SLMP DEVICE  
DEVICE ADDRESS  
DI  
DI  
DI  
10  
2
X
M
Y
0x000  
0x000  
0x000  
8
· Virtual I/O modules configuration  
Slot No.  
1
2
Virtual DI Virtual DI  
module 1 module 2  
Data Allocation  
1
1
· Data configuration  
CH  
ADDRESS  
n+0  
F
Y3  
E
Y2  
D
Y1  
C
Y0  
B
A
9
X9  
8
X8  
7
X7  
6
X6  
5
X5  
4
X4  
3
2
1
0
Virtual DI module 1  
Virtual DI module 2  
M1 M0  
X3  
Y7  
X2  
Y6  
X1  
Y5  
X0  
Y4  
n+1  
In this example, total numbers of channles are 20 and uses 2 virtual DI modules. Real I/O modules are mounted on Slots No. 1 and  
2, however, the network module (R3-NC3) recognizes that each of Slots No. 1 to 3 is occupied. That is, R3-NC3 recognizes R3-SV4  
mounted on Slot No.1 as it is and recognizes R3-GSLMP1 mounted on Slot No.2 as divided into two modules and occupying Slots  
No. 2 and 3.  
R3-BS06  
SLOT  
REAL MODULE VIRTUAL MODULE DATA ALLOCATION  
NO. OF WORDS  
R3-  
SV4  
R3  
-
R3-  
NC3  
R3-  
PS1  
Slot No. 1 R3-SV4  
Slot No. 2 R3-GSLMP1  
Slot No. 3 No module  
Slot No. 4 No module  
Slot No. 5 R3-NC3  
Slot No. 6 R3-PS1  
4
1
1
4 words  
GSLMP1  
R3-GSLMP1 (1/2)  
1 words  
R3-GSLMP1 (2/2)  
1 words  
1
2
3
4
5
6
R3-GSLMP1 SPECIFICATIONS  
ES-8275 Rev.2 Page 7/10  
https://www.m-system.co.jp/  
MODEL: R3-GSLMP1  
· DEVICE CONFIGURATION EXAMPLE 3  
Device setting  
I/O TYPE  
CH. NO.  
20  
SLMP DEVICE  
DEVICE ADDRESS  
AI  
DI  
DI  
D
X
0x000  
0x000  
0x000  
20  
20  
M
· Virtual I/O modules configuration  
2
3
Slot No.  
1
4
5
Virtual AI Virtual AI Virtual DI Virtual DI Virtual DI  
module 1 module 2 module 1 module 2 module 3  
Data Allocation  
16  
16  
1
1
1
· Data configuration  
VIRTUAL AI  
MODULE 1  
(Slot 1)  
D 000  
D 001  
VIRTUAL AI  
VIRTUAL DI  
VIRTUAL DI  
MODULE 2  
(Slot 4)  
VIRTUAL DI  
MODULE 3  
(Slot 5)  
Ch ADDRESS  
ADDRESS  
MODULE 2  
ADDRESS  
n+32  
MODULE 1  
(Slot 3)  
ADDRESS  
ADDRESS  
n+34  
(Slot 2)  
1
2
n+0  
n+1  
n+16  
n+17  
n+18  
n+19  
n+20  
n+21  
n+22  
n+23  
n+24  
n+25  
n+26  
n+27  
n+28  
n+29  
n+30  
n+31  
D 016  
X0 – 15  
n+33  
X16  
19, M0  
11  
M12 – 19  
D 017  
3
n+2  
D 002  
D 003  
D 004  
D 005  
D 006  
D 007  
D 008  
D 009  
D 010  
D 018  
4
n+3  
D 019  
5
n+4  
6
n+5  
7
n+6  
8
n+7  
9
n+8  
10  
11  
12  
13  
14  
15  
16  
n+9  
n+10  
n+11  
n+12  
n+13  
n+14  
n+15  
D 011  
D 012  
D 013  
D 014  
D 015  
ADDRESS  
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
Virtual DI module 1  
Virtual DI module 2  
Virtual DI module 3  
n+32  
n+33  
n+34  
X15 X14 X13 X12 X11 X10  
X9  
M5  
X8  
M4  
X7  
M3  
X6  
X5  
X4  
X3  
X2  
X1  
X0  
M11 M10  
M9  
M8  
M7  
M6  
M2  
M1  
M0  
X19 X18 X17 X16  
M19 M18 M17 M16 M15 M14 M13 M12  
In this example, total numbers of AI channles are 20, total numbers of DI channles are 40 and uses total 5 virtual modules (2 virtual AI  
modules and 3 virtual DI modules). Real I/O modules are mounted on Slots No. 1 and 2, however, the network module  
(R3-NC3) recognizes that each of Slots No. 1 to 6 is occupied. That is, R3-NC3 recognizes R3-SV4 mounted on Slot No.1 as it is and  
recognizes R3-GSLMP1 mounted on Slot No.2 as divided into 5 modules and occupying Slots No. 2 and 6.  
R3-BS06  
1
2
3
4
5
6
7
8
SLOT  
REAL MODULE VIRTUAL MODULE DATA ALLOCATION NO. OF WORDS  
Slot No. 1  
Slot No. 2  
Slot No. 3  
Slot No. 4  
Slot No. 5  
Slot No. 6  
Slot No. 7  
Slot No. 8  
R3-SV4  
4
16  
16  
1
4 words  
16 words  
16 words  
1 words  
1 words  
1 words  
R3-  
SV4 GSLMP1  
R3-  
R3- R3-  
NC3 PS1  
R3-GSLMP1  
No module  
No module  
No module  
No module  
R3-NC3  
R3-GSLMP1 (1/5)  
R3-GSLMP1 (2/5)  
R3-GSLMP1 (3/5)  
R3-GSLMP1 (4/5)  
R3-GSLMP1 (5/5)  
1
1
R3-PS1  
R3-GSLMP1 SPECIFICATIONS  
ES-8275 Rev.2 Page 8/10  
https://www.m-system.co.jp/  
MODEL: R3-GSLMP1  
I/O DATA DESCRIPTIONS  
VIRTUAL ANALOG I/O DATA  
15  
0
16-bit binary data  
VIRTUAL DIGITAL I/O DATA  
0
15  
Input 1 (Output 1)  
Input 2 (Output 2)  
Input 3 (Output 3)  
:
:
Input 16 (Output 16)  
0 : OFF  
1 : ON  
ANALOG/DIGITAL INPUT DATA  
· When the R3-GSLMP1 cannot communicate with SLMP server at the start up, AI or DI  
data turn to 0.  
· When the communication between the R3-GSLMP1 and the SLMP server is lost due to an  
error, the last process values are held until the communication is re-established.  
ANALOG/DIGITAL OUTPUT DATA  
· When the R3-GSLMP1 does not starting communication with SLMP server at the start up,  
write AI or DI data of 0 to the SLMP server.  
· When the communication between the R3 Interface module and the host PLC is lost, the  
last process values are write in the SLMP server. The values are held until the communi  
cation is re-established.  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]  
27.5 [1.08]  
109 [4.29]  
POSITIONING  
GUIDE  
6–M3  
SCREW  
1
4
2
5
3
6
TERMINAL  
COVER  
R3-GSLMP1 SPECIFICATIONS  
ES-8275 Rev.2 Page 9/10  
https://www.m-system.co.jp/  
MODEL: R3-GSLMP1  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
LED  
Isolation  
Control  
Com.  
circuit  
RJ-45 MODULAR JACK  
INTERNAL BUS  
SLMP  
circuit  
1
RUN +  
RUN –  
LED FUNCTION  
DIP SW  
RUN CONTACT OUTPUT  
ETHERNET  
LED  
4
INTERNAL POWER  
STEREO JACK  
CONFIGURATION JACK  
2
3
5
6
SYSTEM CONFIGURATION EXAMPLES  
CC-Link  
Master unit  
R3-  
R3-  
R3-  
GSLMP1 NC3  
PS1  
Ethernet  
MELSEC  
iQ-R series  
CPU unit  
Specifications are subject to change without notice.  
R3-GSLMP1 SPECIFICATIONS  
ES-8275 Rev.2 Page 10/10  
https://www.m-system.co.jp/  

相关型号:

R3-GGLMP/CE

Remote I/O R3 Series INTERFACE I/O MODULE
MSYSTEM

R3-GGLMP/Q

Remote I/O R3 Series INTERFACE I/O MODULE
MSYSTEM

R3-GM1

Remote I/O R3 Series MODBUS INTERFACE MODULE
MSYSTEM

R3-GM1S

Remote I/O R3 Series MODBUS INTERFACE MODULE
MSYSTEM

R3-GM1S/CE

Remote I/O R3 Series MODBUS INTERFACE MODULE
MSYSTEM

R3-GM1S/Q

Remote I/O R3 Series MODBUS INTERFACE MODULE
MSYSTEM

R3-LC2

Remote I/O R3 Series STRAIN GAUGE INPUT MODULE
MSYSTEM

R3-LC2S

Remote I/O R3 Series STRAIN GAUGE INPUT MODULE
MSYSTEM

R3-LC2S/Q

Remote I/O R3 Series STRAIN GAUGE INPUT MODULE
MSYSTEM

R3-LC2W

Remote I/O R3 Series STRAIN GAUGE INPUT MODULE
MSYSTEM

R3-LC2W/Q

Remote I/O R3 Series STRAIN GAUGE INPUT MODULE
MSYSTEM

R3-MEX2

Remote I/O R3 Series VALVE POSITIONER MODULE
MSYSTEM