74HC4017PW-Q100 [NEXPERIA]

Johnson decade counter with 10 decoded outputs;
74HC4017PW-Q100
型号: 74HC4017PW-Q100
厂家: Nexperia    Nexperia
描述:

Johnson decade counter with 10 decoded outputs

光电二极管 逻辑集成电路 触发器
文件: 总22页 (文件大小:757K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
74HC4017-Q100;  
74HCT4017-Q100  
Johnson decade counter with 10 decoded outputs  
Rev. 1 — 24 March 2014  
Product data sheet  
1. General description  
The 74HC4017-Q100; 74HCT4017-Q100 is a 5-stage Johnson decade counter with 10  
decoded outputs (Q0 to Q9). It has an output from the most significant flip-flop (Q5-9), two  
clock inputs (CP0 and CP1) and an overriding asynchronous master reset input (MR).  
Either a LOW-to-HIGH transition at CP0 while CP1 is LOW, or a HIGH-to-LOW transition  
at CP1 while CP0 is HIGH, advances the counter. The Q5-9 output is LOW while the  
counter is in states 5, 6, 7, 8 and 9. When cascading counters, it can be used to drive the  
CP0 input of the next counter. A HIGH on MR resets the counter to zero (Q0 = Q5-9 =  
HIGH; Q1 to Q9 = LOW) independent of the clock inputs (CP0 and CP1). An internal  
circuit: following any illegal code the counter returns to a proper counting mode within 11  
clock pulses provides automatic code correction of the counter. Inputs include clamp  
diodes that enable the use of current limiting resistors to interface inputs to voltages in  
excess of VCC  
.
This product has been qualified to the Automotive Electronics Council (AEC) standard  
Q100 (Grade 1) and is suitable for use in automotive applications.  
2. Features and benefits  
Automotive product qualification in accordance with AEC-Q100 (Grade 1)  
Specified from 40 C to +85 C and from 40 C to +125 C  
Wide supply voltage range from 2.0 V to 6.0 V  
Input levels:  
For 74HC4017-Q100: CMOS level  
For 74HCT4017-Q100: TTL level  
Complies with JEDEC standard no. 7 A  
ESD protection:  
MIL-STD-883, method 3015 exceeds 2000 V  
HBM JESD22-A114F exceeds 2000 V  
MM JESD22-A115-A exceeds 200 V (C = 200 pF, R = 0 )  
Multiple package options  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
3. Ordering information  
Table 1.  
Ordering information  
Type number  
Package  
Temperature range Name  
Description  
Version  
74HC4017-Q100  
74HC4017D-Q100  
40 C to +125 C  
SO16  
plastic small outline package; 16 leads;  
body width 3.9 mm  
SOT109-1  
SOT403-1  
74HC4017PW-Q100 40 C to +125 C  
TSSOP16  
plastic thin shrink small outline package; 16  
leads; body width 4.4 mm  
74HC4017BQ-Q100  
40 C to +125 C  
DHVQFN16 plastic dual in-line compatible thermal-enhanced SOT763-1  
very thin quad flat package; no leads; 16  
terminals; body 2.5 3.5 0.85 mm  
74HCT4017-Q100  
74HCT4017D-Q100  
40 C to +125 C  
SO16  
plastic small outline package; 16 leads;  
body width 3.9 mm  
SOT109-1  
74HCT4017BQ-Q100 40 C to +125 C  
DHVQFN16 plastic dual in-line compatible thermal-enhanced SOT763-1  
very thin quad flat package; no leads; 16  
terminals; body 2.5 3.5 0.85 mm  
4. Functional diagram  
CP1  
13  
CP0  
14  
5-STAGE JOHNSON COUNTER  
MR  
15  
Q5-9  
DECODING AND OUTPUT CIRCUITRY  
12  
Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9  
3
2
4
7
10  
1
5
6
9
11  
001aah242  
Fig 1. Functional diagram  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
2 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
CTRDIV10/DEC  
14  
13  
15  
3
0
1
2
3
4
5
6
7
8
9
CP1  
CP0  
Q0  
Q1  
Q2  
Q3  
Q4  
Q5  
Q6  
Q7  
Q8  
Q9  
3
&
13  
14  
2
2
4
CT = 0  
4
7
7
10  
1
10  
1
5
5
6
15  
MR  
6
9
9
11  
12  
11  
12  
CT5  
Q5-9  
001aah239  
001aah240  
Fig 2. Logic symbol  
Fig 3. IEC logic symbol  
D
Q
D
Q
D
Q
D
Q
D
Q
CP1  
CP0  
MR  
FF  
1
FF  
2
FF  
3
FF  
4
FF  
5
CP Q  
RD  
CP Q  
RD  
CP Q  
RD  
CP Q  
RD  
CP Q  
RD  
Q0  
Q1  
Q2  
Q3  
Q4  
Q5  
Q6  
Q7  
Q8  
Q9  
Q5-9  
001aah243  
Fig 4. Logic diagram  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
3 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
CP0 INPUT  
CP1 INPUT  
MR INPUT  
Q0 OUTPUT  
Q1 OUTPUT  
Q2 OUTPUT  
Q3 OUTPUT  
Q4 OUTPUT  
Q5 OUTPUT  
Q6 OUTPUT  
Q7 OUTPUT  
Q8 OUTPUT  
Q9 OUTPUT  
Q5-9 OUTPUT  
001aah244  
Fig 5. Timing diagram  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
4 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
5. Pinning information  
5.1 Pinning  
ꢀꢁ+&ꢁꢂꢃꢀꢄ4ꢃꢂꢂ  
ꢀꢁ+&7ꢁꢂꢃꢀꢄ4ꢃꢂꢂ  
WHUPLQDOꢋꢁ  
LQGH[ꢋDUHD  
ꢀꢁ+&ꢁꢂꢃꢀꢄ4ꢃꢂꢂ  
ꢀꢁ+&7ꢁꢂꢃꢀꢄ4ꢃꢂꢂ  
ꢁꢀ  
ꢁꢉ  
ꢁꢈ  
ꢁꢃ  
ꢁꢁ  
ꢁꢂ  
4ꢁ  
4ꢂ  
4ꢃ  
4ꢄ  
4ꢇ  
4ꢈ  
05  
ꢁꢄ  
ꢁꢀ  
ꢁꢉ  
ꢁꢈ  
ꢁꢃ  
ꢁꢁ  
ꢁꢂ  
4ꢀ  
4ꢁ  
9
&&  
&3ꢂ  
&3ꢁ  
4ꢀꢅꢆ  
4ꢆ  
05  
&3ꢂ  
&3ꢁ  
4ꢀꢅꢆ  
4ꢆ  
4ꢂ  
4ꢃ  
ꢌꢁꢍ  
*1'  
4ꢄ  
4ꢉ  
4ꢇ  
4ꢈ  
4ꢉ  
*1'  
4ꢊ  
DDDꢀꢁꢂꢁꢃꢄꢆ  
7UDQVSDUHQWꢋWRSꢋYLHZ  
DDDꢀꢁꢂꢁꢃꢄꢅ  
(1) This is not a supply pin. The substrate is attached to this  
pad using conductive die attach material. There is no  
electrical or mechanical requirement to solder this pad.  
However, if it is soldered, the solder land should remain  
floating or be connected to GND.  
Fig 6. Pin configuration SO16 and TSSOP16  
Fig 7. Pin configuration DHVQFN16  
5.2 Pin description  
Table 2.  
Symbol  
Q[0:9]  
GND  
Q5-9  
CP1  
Pin description  
Pin  
Description  
3, 2, 4, 7, 10, 1, 5, 6, 9, 11 decoded output  
8
ground (0 V)  
12  
13  
14  
15  
16  
carry output (active LOW)  
clock input (HIGH-to-LOW edge-triggered)  
clock input (LOW-to-HIGH edge-triggered)  
master reset input (active HIGH)  
supply voltage  
CP0  
MR  
VCC  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
5 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
6. Functional description  
Table 3.  
MR  
Function table[1]  
CP0  
CP1  
Operation  
H
X
X
Q0 = Q5-9 = HIGH;  
Q1 to Q9 = LOW  
L
L
L
L
L
L
H
L
L
counter advances  
counter advances  
no change  
X
H
L
X
H
no change  
no change  
no change  
[1] H = HIGH voltage level;  
L = LOW voltage level;  
X = don’t care;  
= LOW-to-HIGH transition;  
= HIGH-to-LOW transition;  
7. Limiting values  
Table 4.  
Limiting values  
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).  
Symbol  
VCC  
IIK  
Parameter  
Conditions  
Min  
Max  
+7  
Unit  
V
supply voltage  
0.5  
[1]  
[1]  
input clamping current  
output clamping current  
output current  
VI < 0.5 V or VI > VCC + 0.5 V  
VO < 0.5 V or VO > VCC + 0.5 V  
0.5 V < VO < VCC + 0.5 V  
-
20  
20  
25  
50  
mA  
mA  
mA  
mA  
mA  
C  
IOK  
-
IO  
-
ICC  
supply current  
-
IGND  
Tstg  
Ptot  
ground current  
50  
65  
-
storage temperature  
total power dissipation  
SO16 package  
+150  
Tamb = 40 C to +125 C  
[2]  
[3]  
[4]  
-
-
-
500  
500  
500  
mW  
mW  
mW  
TSSOP16 package  
DHVQFN16 package  
[1] The input and output voltage ratings may be exceeded if the input and output current ratings are observed.  
[2] tot derates linearly with 8 mW/K above 70 C.  
P
[3] Ptot derates linearly with 5.5 mW/K above 60 C.  
[4] Ptot derates linearly with 4.5 mW/K above 60 C.  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
6 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
8. Recommended operating conditions  
Table 5.  
Symbol  
Recommended operating conditions  
Parameter Conditions  
Min  
Typ  
Max  
Unit  
74HC4017-Q100  
VCC  
VI  
supply voltage  
2.0  
5.0  
6.0  
V
input voltage  
0
-
VCC  
VCC  
625  
139  
83  
V
VO  
output voltage  
0
-
V
t/V  
input transition rise and fall rate VCC = 2.0 V  
VCC = 4.5 V  
-
-
ns/V  
ns/V  
ns/V  
C  
-
1.67  
VCC = 6.0 V  
-
-
-
Tamb  
ambient temperature  
40  
+125  
74HCT4017-Q100  
VCC  
VI  
supply voltage  
4.5  
0
5.0  
5.5  
V
input voltage  
-
VCC  
VCC  
139  
+125  
V
VO  
output voltage  
0
-
V
t/V  
Tamb  
input transition rise and fall rate VCC = 4.5 V  
ambient temperature  
-
1.67  
-
ns/V  
C  
40  
9. Static characteristics  
Table 6.  
Static characteristics  
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).  
Symbol Parameter  
Conditions  
25 C  
40 C to +85 C 40 C to +125 C Unit  
Min Typ Max  
Min  
Max  
Min  
Max  
74HC4017-Q100  
VIH  
HIGH-level  
input voltage  
VCC = 2.0 V  
1.5 1.2  
3.15 2.4  
4.2 3.2  
-
-
1.5  
-
-
1.5  
-
-
V
V
V
V
V
V
VCC = 4.5 V  
3.15  
3.15  
VCC = 6.0 V  
-
4.2  
-
4.2  
-
VIL  
LOW-level  
input voltage  
VCC = 2.0 V  
-
-
-
0.8  
0.5  
-
-
-
0.5  
1.35  
1.8  
-
-
-
0.5  
1.35  
1.8  
VCC = 4.5 V  
2.1 1.35  
VCC = 6.0 V  
2.8  
1.8  
VOH  
HIGH-level  
VI = VIH or VIL  
output voltage  
IO = 20 A; VCC = 2.0 V  
IO = 20 A; VCC = 4.5 V  
IO = 20 A; VCC = 6.0 V  
IO = 4.0 mA; VCC = 4.5 V  
IO = 5.2 mA; VCC = 6.0 V  
1.9 2.0  
4.4 4.5  
5.9 6.0  
3.98 4.32  
5.48 5.81  
-
-
-
-
-
1.9  
4.4  
-
-
-
-
-
1.9  
4.4  
5.9  
3.7  
5.2  
-
-
-
-
-
V
V
V
V
V
5.9  
3.84  
5.34  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
7 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
Table 6.  
Static characteristics …continued  
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).  
Symbol Parameter  
Conditions  
25 C  
40 C to +85 C 40 C to +125 C Unit  
Min Typ Max  
Min  
Max  
Min  
Max  
VOL  
LOW-level  
VI = VIH or VIL  
output voltage  
IO = 20 A; VCC = 2.0 V  
IO = 20 A; VCC = 4.5 V  
IO = 20 A; VCC = 6.0 V  
IO = 4.0 mA; VCC = 4.5 V  
IO = 5.2 mA; VCC = 6.0 V  
-
-
-
-
-
-
0
0
0
0.1  
0.1  
0.1  
-
-
-
-
-
-
0.1  
0.1  
-
-
-
-
-
-
0.1  
0.1  
V
V
0.1  
0.1  
V
0.15 0.26  
0.16 0.26  
0.33  
0.33  
1.0  
0.4  
0.4  
1.0  
V
V
II  
input leakage VI = VCC or GND;  
current CC = 6.0 V  
-
0.1  
8.0  
-
A  
V
ICC  
CI  
supply current VI = VCC or GND; IO = 0 A;  
CC = 6.0 V  
-
-
-
-
-
80  
-
-
-
160  
-
A  
V
input  
3.5  
pF  
capacitance  
74HCT4017-Q100  
VIH  
HIGH-level  
input voltage  
VCC = 4.5 V to 5.5 V  
VCC = 4.5 V to 5.5 V  
2.0 1.6  
1.2  
-
2.0  
-
-
2.0  
-
-
V
V
VIL  
LOW-level  
-
0.8  
0.8  
0.8  
input voltage  
VOH  
HIGH-level  
output voltage  
VI = VIH or VIL; VCC = 4.5 V  
IO = 20 A  
4.4 4.5  
-
-
4.4  
-
-
4.4  
3.7  
-
-
V
V
IO = 4 mA  
3.98 4.32  
3.84  
VOL  
LOW-level  
output voltage  
VI = VIH or VIL; VCC = 4.5 V  
IO = 20 A  
-
-
-
0
0.1  
-
-
-
0.1  
-
-
-
0.1  
0.4  
V
IO = 4.0 mA  
0.15 0.26  
0.33  
1.0  
V
II  
input leakage VI = VCC or GND;  
current VCC = 5.5 V  
-
0.1  
1.0  
A  
ICC  
ICC  
supply current VI = VCC or GND;  
VCC = 5.5 V; IO = 0 A  
-
-
8.0  
-
80  
-
160  
A  
additional  
supply current VI = VCC 2.1 V;  
other inputs at VCC or GND;  
CC = 4.5 V to 5.5 V;  
IO = 0 A  
per input pin;  
V
CP0 input  
-
-
-
-
25  
40  
50  
3.5  
90  
144  
180  
-
-
-
-
-
113  
180  
225  
-
-
-
-
-
123  
196  
245  
-
A  
A  
A  
pF  
CP1 input  
MR input  
CI  
input  
capacitance  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
8 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
10. Dynamic characteristics  
Table 7.  
Dynamic characteristics  
GND = 0 V; tr = tf = 6 ns; CL = 50 pF; see Figure 11.  
Symbol Parameter  
Conditions  
25 C  
40 C to +85 C 40 C to +125 C Unit  
Min Typ Max  
Min  
Max  
Min  
Max  
74HC4017-Q100  
[1]  
tpd  
propagation  
delay  
CP0 to Qn; CP0 to Q5-9;  
see Figure 10  
VCC = 2.0 V  
VCC = 4.5 V  
-
-
-
63  
23  
20  
230  
46  
-
-
-
-
290  
58  
-
-
-
-
345  
69  
-
ns  
ns  
ns  
VCC = 5.0 V;  
CL = 15 pF  
VCC = 6.0 V  
-
18  
39  
-
49  
-
59  
ns  
CP1 to Qn; CP1 to Q5-9;  
see Figure 10  
VCC = 2.0 V  
VCC = 4.5 V  
-
-
-
61  
22  
20  
250  
50  
-
-
-
-
315  
63  
-
-
-
-
375  
75  
-
ns  
ns  
ns  
VCC = 5.0 V;  
CL = 15 pF  
VCC = 6.0 V  
-
18  
43  
-
54  
-
64  
ns  
tPHL  
HIGH to LOW  
propagation  
delay  
MR to Q[1:9];  
see Figure 10  
VCC = 2.0 V  
VCC = 4.5 V  
VCC = 6.0 V  
-
-
-
52  
19  
15  
230  
46  
-
-
-
290  
58  
-
-
-
345  
69  
ns  
ns  
ns  
39  
49  
59  
tPLH  
LOW to HIGH  
propagation  
delay  
MR to Q5-9, Q0;  
see Figure 10  
VCC = 2.0 V  
VCC = 4.5 V  
VCC = 6.0 V  
see Figure 10  
VCC = 2.0 V  
VCC = 4.5 V  
VCC = 6.0 V  
-
-
-
55  
20  
16  
230  
46  
-
-
-
290  
58  
-
-
-
345  
69  
ns  
ns  
ns  
39  
49  
59  
[2]  
tt  
transition time  
pulse width  
-
-
-
19  
7
75  
15  
13  
-
-
-
95  
19  
16  
-
-
-
110  
22  
ns  
ns  
ns  
6
19  
tW  
CP0 and CP1 (HIGH or  
LOW); see Figure 9  
VCC = 2.0 V  
VCC = 4.5 V  
80  
16  
14  
17  
6
-
-
-
100  
20  
-
-
-
120  
24  
-
-
-
ns  
ns  
ns  
VCC = 6.0 V  
5
17  
20  
MR (HIGH); see Figure 9  
VCC = 2.0 V  
80  
16  
14  
19  
7
-
-
-
100  
20  
-
-
-
120  
24  
-
-
-
ns  
ns  
ns  
VCC = 4.5 V  
VCC = 6.0 V  
6
17  
20  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
9 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
Table 7.  
Dynamic characteristics …continued  
GND = 0 V; tr = tf = 6 ns; CL = 50 pF; see Figure 11.  
Symbol Parameter  
Conditions  
25 C  
40 C to +85 C 40 C to +125 C Unit  
Min Typ Max  
Min  
Max  
Min  
Max  
tsu  
set-up time  
hold time  
CP1 to CP0; CP0 to CP1;  
see Figure 8  
VCC = 2.0 V  
VCC = 4.5 V  
VCC = 6.0 V  
50  
10  
9
8  
3  
2  
-
-
-
65  
13  
11  
-
-
-
75  
15  
13  
-
-
-
ns  
ns  
ns  
th  
CP1 to CP0; CP0 to CP1;  
see Figure 8  
VCC = 2.0 V  
VCC = 4.5 V  
VCC = 6.0 V  
50  
10  
9
17  
6
-
-
-
65  
13  
11  
-
-
-
75  
15  
13  
-
-
-
ns  
ns  
ns  
5
trec  
recovery time  
MR to CP0 and  
MR to CP1; see Figure 9  
VCC = 2.0 V  
VCC = 4.5 V  
5
5
5
17  
6  
-
-
-
5
5
5
-
-
-
5
5
5
-
-
-
ns  
ns  
ns  
VCC = 6.0 V  
5  
fmax  
maximum  
frequency  
CP0 or CP1; see Figure 9  
VCC = 2.0 V  
6.0  
30  
-
23  
70  
77  
-
-
-
4.8  
24  
-
-
-
-
4.0  
20  
-
-
-
-
MHz  
MHz  
MHz  
VCC = 4.5 V  
VCC = 5.0 V;  
CL = 15 pF  
VCC = 6.0 V  
25  
-
83  
35  
-
-
28  
-
-
-
24  
-
-
-
MHz  
pF  
[3]  
[1]  
CPD  
power  
VI = GND to VCC;  
VCC = 5 V; fi = 1 MHz  
dissipation  
capacitance  
74HCT4017-Q100  
tpd  
propagation  
CP0 to Qn; CP0 to Q5-9;  
see Figure 10  
delay  
VCC = 4.5 V  
-
-
25  
21  
46  
-
-
-
58  
-
-
-
69  
-
ns  
ns  
VCC = 5.0 V;  
CL = 15 pF  
CP1 to Qn; CP1 to Q5-9;  
see Figure 10  
VCC = 4.5 V  
-
-
25  
21  
50  
-
-
-
63  
-
-
-
75  
-
ns  
ns  
VCC = 5.0 V;  
CL = 15 pF  
tPHL  
HIGH to LOW  
propagation  
delay  
MR to Q[1:9];  
see Figure 10  
VCC = 4.5 V  
-
-
22  
20  
46  
46  
-
-
58  
58  
-
-
69  
69  
ns  
ns  
tPLH  
LOW to HIGH  
propagation  
delay  
MR to Q5-9, Q0;  
see Figure 10  
VCC = 4.5 V  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
10 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
Table 7.  
Dynamic characteristics …continued  
GND = 0 V; tr = tf = 6 ns; CL = 50 pF; see Figure 11.  
Symbol Parameter  
Conditions  
25 C  
40 C to +85 C 40 C to +125 C Unit  
Min Typ Max  
Min  
Max  
Min  
Max  
[2]  
tt  
transition time  
pulse width  
see Figure 10  
VCC = 4.5 V  
-
7
15  
-
19  
-
22  
ns  
tW  
CP0 and CP1 (HIGH or  
LOW); see Figure 9  
VCC = 4.5 V  
16  
16  
7
4
-
-
20  
20  
-
-
24  
24  
-
-
ns  
ns  
MR (HIGH); see Figure 9  
VCC = 4.5 V  
tsu  
set-up time  
hold time  
CP1 to CP0; CP0 to CP1;  
see Figure 8  
VCC = 4.5 V  
10  
10  
5
3  
6
-
-
-
13  
13  
5
-
-
-
15  
15  
5
-
-
-
ns  
ns  
ns  
th  
CP1 to CP0; CP0 to CP1;  
see Figure 8  
VCC = 4.5 V  
trec  
recovery time  
MR to CP0 and  
MR to CP1; see Figure 9  
VCC = 4.5 V  
5  
fmax  
maximum  
frequency  
CP0 or CP1; see Figure 9  
VCC = 4.5 V  
30  
-
61  
67  
-
-
24  
-
-
-
20  
-
-
-
MHz  
MHz  
VCC = 5.0 V;  
CL = 15 pF  
[3]  
CPD  
power  
VI = GND to VCC 1.5 V;  
-
36  
-
-
-
-
-
pF  
dissipation  
capacitance  
VCC = 5 V; fi = 1 MHz  
[1] tpd is the same as tPHL and tPLH  
.
[2] tt is the same as tTHL and tTLH  
.
[3]  
CPD is used to determine the dynamic power dissipation (PD in W):  
PD = CPD VCC2 fi N + (CL VCC2 fo) where:  
fi = input frequency in MHz;  
fo = output frequency in MHz;  
CL = output load capacitance in pF;  
VCC = supply voltage in V;  
N = number of inputs switching;  
(CL VCC2 fo) = sum of outputs.  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
11 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
11. Waveforms  
V
I
CP0 input  
GND  
V
M
t
t
t
t
h
su  
h
su  
V
I
CP1 input  
GND  
V
M
001aah245  
Measurement points are given in Table 8.  
VOL and VOH are typical voltage output levels that occur with the output load.  
Fig 8. Waveforms showing the set-up and hold times for CP0 to CP1 and CP1 to CP0  
1/f  
max  
t
W
V
I
CP0 input  
GND  
V
V
M
M
1/f  
max  
V
I
CP1 input  
GND  
t
W
t
rec  
V
I
MR input  
GND  
V
M
t
W
V
OH  
Q1 - Q9  
output  
V
M
M
V
OL  
t
t
PHL  
PLH  
V
OH  
Q0, Q5 - Q9  
output  
V
V
OL  
001aah246  
Measurement points are given in Table 8.  
VOL and VOH are typical voltage output levels that occur with the output load.  
Fig 9. Waveforms showing minimum pulse widths, maximum CP input frequencies, recovery times and output  
propagation delays  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
12 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
V
I
CP0 input  
GND  
V
V
M
M
V
I
CP1 input  
GND  
t
t
t
t
PHL  
PLH  
PLH  
PHL  
V
OH  
Q1 - Q9  
output  
V
M
V
OL  
V
OH  
Q0, Q5 - Q9  
output  
V
M
V
OL  
t
t
TLH  
THL  
001aah247  
Measurement points are given in Table 8.  
OL and VOH are typical voltage output levels that occur with the output load.  
V
Conditions: CP1 = LOW while CP0 is triggered on a LOW-to-HIGH transition and CP0 = HIGH, while CP1 is triggered on a  
HIGH-to-LOW transition.  
Fig 10. Waveforms showing propagation delays for CP to Qn outputs and output transition times  
Table 8.  
Type  
Measurement points  
Input  
VM  
Output  
VM  
74HC4017-Q100  
74HCT4017-Q100  
0.5 VCC  
1.3 V  
0.5 VCC  
1.3 V  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
13 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
t
W
V
I
90 %  
negative  
pulse  
V
V
V
M
M
10 %  
0 V  
t
t
r
f
t
t
f
r
V
I
90 %  
positive  
pulse  
V
M
M
10 %  
0 V  
t
W
V
CC  
V
CC  
V
V
O
I
R
L
S1  
G
open  
DUT  
R
T
C
L
001aad983  
Test data is given in Table 9.  
Definitions test circuit:  
RT = Termination resistance should be equal to output impedance Zo of the pulse generator.  
CL = Load capacitance including jig and probe capacitance.  
RL = Load resistance.  
S1 = Test selection switch.  
Fig 11. Load circuitry for measuring switching times  
Table 9.  
Type  
Test data  
Input  
Load  
S1 position  
tPHL, tPLH  
open  
VI  
tr, tf  
6 ns  
6 ns  
CL  
RL  
tPZH, tPHZ  
GND  
tPZL, tPLZ  
VCC  
74HC4017-Q100  
VCC  
15 pF, 50 pF  
15 pF, 50 pF  
1 k  
1 k  
74HCT4017-Q100 3 V  
open  
GND  
VCC  
12. Application information  
Some examples of applications for the 74HC4017-Q100; 74HCT4017-Q100 are:  
Decade counter with decimal decoding  
1 out of n decoding counter (when cascaded)  
Sequential controller  
Timer  
Figure 12 shows a technique for extending the number of decoded output states for the  
74HC4017-Q100; 74HCT4017-Q100. Decoded outputs are sequential within each stage  
and from stage to stage, with no dead time (except propagation delay).  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
14 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
05  
05  
05  
&3ꢂ  
&3ꢂ  
&3ꢂ  
ꢀꢁ+&ꢁꢂꢃꢀꢄ4ꢃꢂꢂ  
ꢀꢁ+&ꢁꢂꢃꢀꢄ4ꢃꢂꢂ  
ꢀꢁ+&ꢁꢂꢃꢀꢄ4ꢃꢂꢂ  
ꢀꢁ+&7ꢁꢂꢃꢀꢄ4ꢃꢂꢂ  
&3ꢁ  
ꢀꢁ+&7ꢁꢂꢃꢀꢄ4ꢃꢂꢂ  
ꢀꢁ+&7ꢁꢂꢃꢀꢄ4ꢃꢂꢂ  
&3ꢁ  
ꢅꢋꢅꢋꢅꢋꢅ  
&3ꢁ  
ꢅꢋꢅꢋꢅꢋꢅ  
ꢅꢋꢅꢋꢅꢋꢅꢋꢅꢋꢅ  
4ꢂ 4ꢁ  
4ꢊ 4ꢆ  
4ꢂ 4ꢁ  
4ꢊ 4ꢆ  
4ꢁ  
4ꢊ 4ꢆ  
ꢆꢋGHFRGHG  
RXWSXWV  
ꢊꢋGHFRGHG  
RXWSXWV  
ꢊꢋGHFRGHG  
RXWSXWV  
FORFN  
ILUVWꢋVWDJH  
LQWHUPHGLDWHꢋVWDJHV  
ODVWꢋVWDJH  
DDDꢀꢁꢂꢁꢃꢄꢃ  
Fig 12. Counter expansion  
Remark: Do not enable the counter on CP1 when CP0 is HIGH, or on CP0 when CP1 is  
LOW. It causes an extra count.  
Figure 13 shows an example of a divide-by 2 through divide-by 10 circuit using one  
74HC4017-Q100; 74HCT4017-Q100. Since the 74HC4017-Q100; 74HCT4017-Q100 has  
an asynchronous reset, the output pulse widths are narrow (minimum expected pulse  
width is 6 ns). The output pulse widths can be enlarged by inserting an RC network at the  
MR input.  
ꢀꢁ+&ꢁꢂꢃꢀꢄ4ꢃꢂꢂ  
ꢀꢁ+&7ꢁꢂꢃꢀꢄ4ꢃꢂꢂ  
GLYLGHꢋꢅꢋE\ꢋꢀ  
4ꢀ  
4ꢁ  
4ꢂ  
4ꢃ  
4ꢄ  
4ꢇ  
4ꢈ  
*1'  
9
9
&&  
&&  
05  
&3ꢂ  
&3ꢁ  
4ꢀꢅꢆ  
4ꢆ  
ILQ  
GLYLGHꢋꢅꢋE\ꢋꢃ  
GLYLGHꢋꢅꢋE\ꢋꢄ  
GLYLGHꢋꢅꢋE\ꢋꢇ  
GLYLGHꢋꢅꢋE\ꢋꢈ  
GLYLGHꢋꢅꢋE\ꢋꢁꢂ  
GLYLGHꢋꢅꢋE\ꢋꢆ  
GLYLGHꢋꢅꢋE\ꢋꢉ  
GLYLGHꢋꢅꢋE\ꢋꢊ  
4ꢉ  
4ꢊ  
IRXW  
DDDꢀꢁꢂꢁꢃꢄꢄ  
Fig 13. Divide-by 2 through divide-by 10  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
15 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
13. Package outline  
SO16: plastic small outline package; 16 leads; body width 3.9 mm  
SOT109-1  
D
E
A
X
v
c
y
H
M
A
E
Z
16  
9
Q
A
2
A
(A )  
3
A
1
pin 1 index  
θ
L
p
L
1
8
e
w
M
detail X  
b
p
0
2.5  
scale  
5 mm  
DIMENSIONS (inch dimensions are derived from the original mm dimensions)  
A
(1)  
(1)  
(1)  
UNIT  
A
A
A
b
c
D
E
e
H
L
L
p
Q
v
w
y
Z
θ
1
2
3
p
E
max.  
0.25  
0.10  
1.45  
1.25  
0.49  
0.36  
0.25  
0.19  
10.0  
9.8  
4.0  
3.8  
6.2  
5.8  
1.0  
0.4  
0.7  
0.6  
0.7  
0.3  
mm  
1.27  
0.05  
1.05  
0.041  
1.75  
0.25  
0.01  
0.25  
0.01  
0.25  
0.1  
8o  
0o  
0.010 0.057  
0.004 0.049  
0.019 0.0100 0.39  
0.014 0.0075 0.38  
0.16  
0.15  
0.244  
0.228  
0.039 0.028  
0.016 0.020  
0.028  
0.012  
inches  
0.069  
0.01 0.004  
Note  
1. Plastic or metal protrusions of 0.15 mm (0.006 inch) maximum per side are not included.  
REFERENCES  
OUTLINE  
EUROPEAN  
PROJECTION  
ISSUE DATE  
VERSION  
IEC  
JEDEC  
JEITA  
99-12-27  
03-02-19  
SOT109-1  
076E07  
MS-012  
Fig 14. Package outline SOT109-1 (SO16)  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
16 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
TSSOP16: plastic thin shrink small outline package; 16 leads; body width 4.4 mm  
SOT403-1  
D
E
A
X
c
y
H
v
M
A
E
Z
9
16  
Q
(A )  
3
A
2
A
A
1
pin 1 index  
θ
L
p
L
1
8
detail X  
w
M
b
p
e
0
2.5  
5 mm  
scale  
DIMENSIONS (mm are the original dimensions)  
A
(1)  
(2)  
(1)  
UNIT  
A
A
A
b
c
D
E
e
H
L
L
Q
v
w
y
Z
θ
1
2
3
p
E
p
max.  
8o  
0o  
0.15  
0.05  
0.95  
0.80  
0.30  
0.19  
0.2  
0.1  
5.1  
4.9  
4.5  
4.3  
6.6  
6.2  
0.75  
0.50  
0.4  
0.3  
0.40  
0.06  
mm  
1.1  
0.65  
0.25  
1
0.2  
0.13  
0.1  
Notes  
1. Plastic or metal protrusions of 0.15 mm maximum per side are not included.  
2. Plastic interlead protrusions of 0.25 mm maximum per side are not included.  
REFERENCES  
OUTLINE  
EUROPEAN  
PROJECTION  
ISSUE DATE  
VERSION  
IEC  
JEDEC  
JEITA  
99-12-27  
03-02-18  
SOT403-1  
MO-153  
Fig 15. Package outline SOT403-1 (TSSOP16)  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
17 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
DHVQFN16: plastic dual in-line compatible thermal enhanced very thin quad flat package; no leads;  
16 terminals; body 2.5 x 3.5 x 0.85 mm  
SOT763-1  
B
A
D
A
A
1
E
c
detail X  
terminal 1  
index area  
C
terminal 1  
index area  
e
1
y
y
e
b
v
M
C
C
A
B
C
1
w
M
2
7
L
1
8
9
E
h
e
16  
15  
10  
D
h
X
0
2.5  
scale  
5 mm  
DIMENSIONS (mm are the original dimensions)  
(1)  
A
(1)  
(1)  
UNIT  
A
b
c
E
e
e
y
D
D
E
L
v
w
y
1
1
h
1
h
max.  
0.05 0.30  
0.00 0.18  
3.6  
3.4  
2.15  
1.85  
2.6  
2.4  
1.15  
0.85  
0.5  
0.3  
mm  
0.05  
0.1  
1
0.2  
0.5  
2.5  
0.1  
0.05  
Note  
1. Plastic or metal protrusions of 0.075 mm maximum per side are not included.  
REFERENCES  
OUTLINE  
EUROPEAN  
PROJECTION  
ISSUE DATE  
VERSION  
IEC  
JEDEC  
JEITA  
02-10-17  
03-01-27  
SOT763-1  
- - -  
MO-241  
- - -  
Fig 16. Package outline SOT763-1 (DHVQFN16)  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
18 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
14. Abbreviations  
Table 10. Abbreviations  
Acronym  
CMOS  
DUT  
Description  
Complementary Metal Oxide Semiconductor  
Device Under Test  
ElectroStatic Discharge  
Human Body Model  
Machine Model  
ESD  
HBM  
MM  
MIL  
Military  
TTL  
Transistor-Transistor Logic  
15. Revision history  
Table 11. Revision history  
Document ID  
Release date  
20140324  
Data sheet status  
Change notice Supersedes  
74HC_HCT4017_Q100 v.1  
Product data sheet  
-
-
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
19 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
16. Legal information  
16.1 Data sheet status  
Document status[1][2]  
Product status[3]  
Development  
Definition  
Objective [short] data sheet  
This document contains data from the objective specification for product development.  
This document contains data from the preliminary specification.  
This document contains the product specification.  
Preliminary [short] data sheet Qualification  
Product [short] data sheet Production  
[1]  
[2]  
[3]  
Please consult the most recently issued document before initiating or completing a design.  
The term ‘short data sheet’ is explained in section “Definitions”.  
The product status of device(s) described in this document may have changed since this document was published and may differ in case of multiple devices. The latest product status  
information is available on the Internet at URL http://www.nexperia.com.  
Suitability for use in automotive applications — This Nexperia  
product has been qualified for use in automotive  
16.2 Definitions  
applications. Unless otherwise agreed in writing, the product is not designed,  
authorized or warranted to be suitable for use in life support, life-critical or  
safety-critical systems or equipment, nor in applications where failure or  
malfunction of a Nexperia product can reasonably be expected  
to result in personal injury, death or severe property or environmental  
damage. Nexperia and its suppliers accept no liability for  
inclusion and/or use of Nexperia products in such equipment or  
applications and therefore such inclusion and/or use is at the customer's own  
risk.  
Draft — The document is a draft version only. The content is still under  
internal review and subject to formal approval, which may result in  
modifications or additions. Nexperia does not give any  
representations or warranties as to the accuracy or completeness of  
information included herein and shall have no liability for the consequences of  
use of such information.  
Short data sheet — A short data sheet is an extract from a full data sheet  
with the same product type number(s) and title. A short data sheet is intended  
for quick reference only and should not be relied upon to contain detailed and  
full information. For detailed and full information see the relevant full data  
sheet, which is available on request via the local Nexperia sales  
office. In case of any inconsistency or conflict with the short data sheet, the  
full data sheet shall prevail.  
Applications — Applications that are described herein for any of these  
products are for illustrative purposes only. Nexperia makes no  
representation or warranty that such applications will be suitable for the  
specified use without further testing or modification.  
Customers are responsible for the design and operation of their applications  
and products using Nexperia products, and Nexperia  
Product specification — The information and data provided in a Product  
data sheet shall define the specification of the product as agreed between  
Nexperia and its customer, unless Nexperia and  
customer have explicitly agreed otherwise in writing. In no event however,  
shall an agreement be valid in which the Nexperia product is  
deemed to offer functions and qualities beyond those described in the  
Product data sheet.  
accepts no liability for any assistance with applications or customer product  
design. It is customer’s sole responsibility to determine whether the Nexperia  
product is suitable and fit for the customer’s applications and  
products planned, as well as for the planned application and use of  
customer’s third party customer(s). Customers should provide appropriate  
design and operating safeguards to minimize the risks associated with their  
applications and products.  
Nexperia does not accept any liability related to any default,  
16.3 Disclaimers  
damage, costs or problem which is based on any weakness or default in the  
customer’s applications or products, or the application or use by customer’s  
third party customer(s). Customer is responsible for doing all necessary  
testing for the customer’s applications and products using Nexperia  
products in order to avoid a default of the applications and  
Limited warranty and liability — Information in this document is believed to  
be accurate and reliable. However, Nexperia does not give any  
representations or warranties, expressed or implied, as to the accuracy or  
completeness of such information and shall have no liability for the  
consequences of use of such information. Nexperia takes no  
responsibility for the content in this document if provided by an information  
source outside of Nexperia.  
the products or of the application or use by customer’s third party  
customer(s). Nexperia does not accept any liability in this respect.  
Limiting values — Stress above one or more limiting values (as defined in  
the Absolute Maximum Ratings System of IEC 60134) will cause permanent  
damage to the device. Limiting values are stress ratings only and (proper)  
operation of the device at these or any other conditions above those given in  
the Recommended operating conditions section (if present) or the  
Characteristics sections of this document is not warranted. Constant or  
repeated exposure to limiting values will permanently and irreversibly affect  
the quality and reliability of the device.  
In no event shall Nexperia be liable for any indirect, incidental,  
punitive, special or consequential damages (including - without limitation - lost  
profits, lost savings, business interruption, costs related to the removal or  
replacement of any products or rework charges) whether or not such  
damages are based on tort (including negligence), warranty, breach of  
contract or any other legal theory.  
Notwithstanding any damages that customer might incur for any reason  
whatsoever, Nexperia’s aggregate and cumulative liability towards  
customer for the products described herein shall be limited in accordance  
with the Terms and conditions of commercial sale of Nexperia.  
Terms and conditions of commercial sale — Nexperia  
products are sold subject to the general terms and conditions of commercial  
sale, as published at http://www.nexperia.com/profile/terms, unless otherwise  
agreed in a valid written individual agreement. In case an individual  
agreement is concluded only the terms and conditions of the respective  
agreement shall apply. Nexperia hereby expressly objects to  
applying the customer’s general terms and conditions with regard to the  
purchase of Nexperia products by customer.  
Right to make changes — Nexperia reserves the right to make  
changes to information published in this document, including without  
limitation specifications and product descriptions, at any time and without  
notice. This document supersedes and replaces all information supplied prior  
to the publication hereof.  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
20 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
No offer to sell or license — Nothing in this document may be interpreted or  
construed as an offer to sell products that is open for acceptance or the grant,  
conveyance or implication of any license under any copyrights, patents or  
other industrial or intellectual property rights.  
Translations — A non-English (translated) version of a document is for  
reference only. The English version shall prevail in case of any discrepancy  
between the translated and English versions.  
Export control — This document as well as the item(s) described herein  
may be subject to export control regulations. Export might require a prior  
authorization from competent authorities.  
16.4 Trademarks  
Notice: All referenced brands, product names, service names and trademarks  
are the property of their respective owners.  
17. Contact information  
For more information, please visit: http://www.nexperia.com  
For sales office addresses, please send an email to: salesaddresses@nexperia.com  
74HC_HCT4017_Q100  
All information provided in this document is subject to legal disclaimers.  
©
Nexperia B.V. 2017. All rights reserved  
Product data sheet  
Rev. 1 — 24 March 2014  
21 of 22  
74HC4017-Q100; 74HCT4017-Q100  
Nexperia  
Johnson decade counter with 10 decoded outputs  
18. Contents  
1
2
3
4
General description. . . . . . . . . . . . . . . . . . . . . . 1  
Features and benefits . . . . . . . . . . . . . . . . . . . . 1  
Ordering information. . . . . . . . . . . . . . . . . . . . . 2  
Functional diagram . . . . . . . . . . . . . . . . . . . . . . 2  
5
5.1  
5.2  
Pinning information. . . . . . . . . . . . . . . . . . . . . . 5  
Pinning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
Pin description . . . . . . . . . . . . . . . . . . . . . . . . . 5  
6
Functional description . . . . . . . . . . . . . . . . . . . 6  
Limiting values. . . . . . . . . . . . . . . . . . . . . . . . . . 6  
Recommended operating conditions. . . . . . . . 7  
Static characteristics. . . . . . . . . . . . . . . . . . . . . 7  
Dynamic characteristics . . . . . . . . . . . . . . . . . . 9  
Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
Application information. . . . . . . . . . . . . . . . . . 14  
Package outline . . . . . . . . . . . . . . . . . . . . . . . . 16  
Abbreviations. . . . . . . . . . . . . . . . . . . . . . . . . . 19  
Revision history. . . . . . . . . . . . . . . . . . . . . . . . 19  
7
8
9
10  
11  
12  
13  
14  
15  
16  
Legal information. . . . . . . . . . . . . . . . . . . . . . . 20  
Data sheet status . . . . . . . . . . . . . . . . . . . . . . 20  
Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
Disclaimers. . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
Trademarks. . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
16.1  
16.2  
16.3  
16.4  
17  
18  
Contact information. . . . . . . . . . . . . . . . . . . . . 21  
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22  
© Nexperia B.V. 2017. All rights reserved  
For more information, please visit: http://www.nexperia.com  
For sales office addresses, please send an email to: salesaddresses@nexperia.com  
Date of release: 24 March 2014  

相关型号:

74HC4020

14-stage binary ripple counter
NXP

74HC4020-Q100

14-stage binary ripple counter
NEXPERIA

74HC4020BQ

14-stage binary ripple counterProduction
NEXPERIA

74HC4020BQ-Q100

14-stage binary ripple counter
NEXPERIA

74HC4020D

14-stage binary ripple counter
NXP

74HC4020D

14-stage binary ripple counterProduction
NEXPERIA

74HC4020D,652

74HC4020; 74HCT4020 - 14-stage binary ripple counter SOP 16-Pin
NXP

74HC4020D-Q100

14-stage binary ripple counter
NEXPERIA

74HC4020D-T

Asynchronous Up Counter
ETC

74HC4020D/T3

IC HC/UH SERIES, ASYN NEGATIVE EDGE TRIGGERED 14-BIT UP BINARY COUNTER, PDSO16, PLASTIC, SOP-16, Counter
NXP

74HC4020DB

14-stage binary ripple counter
NXP

74HC4020DB,118

74HC4020; 74HCT4020 - 14-stage binary ripple counter SSOP1 16-Pin
NXP