TF037E-2000-F [NIDEC]

Blowers Outline;
TF037E-2000-F
型号: TF037E-2000-F
厂家: NIDEC COMPONENTS    NIDEC COMPONENTS
描述:

Blowers Outline

文件: 总8页 (文件大小:254K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
NIDEC COPAL ELECTRONICS CORP.  
1
7
/
Model No. TF037E-2000-F  
Specifications  
Issuing Date  
Aug.1, 2017  
1.Scope  
This specification applies to Blower TF037E-2000-F (hereinafter referred to as "the PRODUCT"),  
a product of NIDEC COPAL ELECTRONICS CORP. (hereinafter referred to as "NCEL").  
Driving circuit : NCEL's standard driving circuit  
2.Specification  
(Note1) Unless otherwise specified, the environmental conditions are 23℃±5℃,normal humidity,  
and atmospheric pressure range 90 to 106kPa.  
(Note2) Measuring conditions :  
Driving circuit = NCEL's standard driving circuit,  
Supply voltage = DC24V, measurement equipment = NCEL's standard equipment  
(Note3)  
The below specifications specify the characteristics of the Blowers at the time of shipment.  
The characteristics may change over time depending on the usage conditions and  
environment.  
(Note4) Please contact us if you'd like to operate the PRODUCT outside of specifications.  
(Note5) The specification value is measured under the plate by the vertical position to axis.  
No.  
1
Items  
Specification  
Remarks  
Rated Voltage  
DC 24 V±10%  
Direction of  
Rotation  
Looking down from the air  
inlet.  
2
CCW (Counter-Clockwise)  
Air  
3
Kind of Gas  
Configuration  
Type of Motor  
Noncorrosive gas  
4
Motor with Centrifugal Blade  
DC Brushless Motor  
Without driving circuit  
5
6
Number of Poles 8 Poles (4 pole pairs)  
7
Drive System  
Bearings  
Impeller  
3 Phase, Bipolar  
8
Aero-Dynamic Bearings  
Centrifugal Turbo Blade  
Drawing ︓ 6404-00655-00  
9
Please refer to attached  
drawing.  
10  
Outline  
No vibration, shock, or  
gyration is to be applied during  
operation.  
Mounting  
Direction  
Shaft vertical to ground, air inlet facing  
upwards.(±5°)  
11  
NIDEC COPAL ELECTRONICS CORP.  
Specification  
2
7
/
No.  
12  
Items  
Remarks  
Max. Input Coil  
Current  
3.0 A rms  
Excluding inrush current.  
max.  
Rated Power  
Supply Current  
Rated Power  
Consumption  
13  
14  
15  
0.86 A  
max.  
at 3.0kPa, 100L/min, DC 24V  
at 3.0kPa, 100L/min, DC 24V  
at 3.0kPa  
22.7 W max.  
100 L/min  
Rated Air Flow  
16 Minimum Air Flow 10 L/min  
17 Rated Pressure 3.0 kPa  
Maximum  
at 100L/min  
18  
19  
20  
4.5 kPa  
Absolute maximum pressure  
at 3.0kPa, 100L/min  
Pressure  
Rated Rotation  
Speed  
35,500 r/min (reference value)  
6,000 r/min  
Min.Rotation  
Speed  
Pressure-air flow must be  
within the "area of use"  
specified in "5. Operating  
Range" on P.5.  
Max.Rotation  
Speed  
21  
45,000 r/min  
22 Torque Constant 0.0020〜0.0026 N・m/A (reference value)  
at 3.0kPa, 100L/min.  
Acoustic Audible  
Measured at 1m from air inlet.  
Include background noise  
15dB(A).  
23  
65.0 dB(A )max.  
0.36〜0.66  
Noise  
24 Coil Resistance  
(reference value)  
at 20℃ (Between 2 phase)  
ohm  
at 20℃, 10kHz  
(Between 2 phase)  
25 Coil Inductance 17〜23 μH  
26 Insulation Class Class E  
Insulation  
(reference value)  
JIS C 4003  
DC500V,between terminal pins  
and plate  
JIS C 4003  
min.  
ohm  
27  
20M  
Resistance  
AC600V for 1sec. between  
terminal pins and Plate.  
JIS C 4003  
Dielectric  
Strength  
28  
Leak current to be less than 1mA.  
165 g (reference value)  
29  
30  
Weight  
19 g・cm2  
Rotor Inertia  
(reference value)  
Max. allowable force to the  
intake (upper housing) in axial  
direction.  
Max. Axial  
Loading  
31  
3N  
max.  
NIDEC COPAL ELECTRONICS CORP.  
Specification  
3
7
/
No.  
32  
33  
34  
35  
Items  
Remarks  
Operating  
Temperature  
-10 to 60℃  
Range  
Operating  
10 to 90%RH  
-20 to 60℃  
No condensation  
No condensation  
Humidity Range  
Storage  
Temperature  
Range  
Storage  
10 to 90%RH  
Humidity Range  
The Blower shall satisfy Specification  
No.12 〜 28 after the following test.  
Kind of  
Vibration  
Sweep  
@ amplitude  
10〜22Hz  
Resistance to  
Vibration  
Frequency  
Range  
1mm  
36  
Non-operating  
@ acceleration  
22〜50Hz  
19.6m/s2 (2G)  
Sweep  
To-and-fro, approx. 5min.  
X, Y, Z directions, 60min.  
each  
Test Time  
The Blower shall satisfy Specification  
No.12 〜 28 after the following test.  
294m/s2(30G)  
Acceleration  
Resistance to  
Shock  
Pulse Width  
6ms  
37  
Non-operating  
Shock  
Wave  
Semi-sinusoidal wave  
Number of X, Y, Z, directions, once per  
Shock each direction  
NIDEC COPAL ELECTRONICS CORP.  
4
7
/
3.Interface  
Pin No.  
1
Symbol  
Signal  
Air Inlet  
Hall Element Power Supply  
(+12V)  
Vcc  
2
3
4
5
6
7
H2-  
H2+  
H3-  
Hall Element 2 Output  
Hall Element 3 Output  
Hall Element 1 Output  
GND  
1
12  
H3+  
H1-  
Manufacturer J.S.T. Mfg. Co. Ltd.  
H1+  
Part No.  
ꢀSM12B-PASS  
8
GND  
TH  
V
Thermistor Output  
Motor Coil (V)  
9
【Mating Connector】  
Manufacturer J.S.T. Mfg. Co., Ltd.  
10  
(insulation displacement  
connector)  
ꢀ(retainer︓PAFS-12V-S)  
ꢀ12PAF-6S  
Motor Coil (W)  
Motor Coil (U)  
11  
12  
W
U
Part No.  
(crimp type)  
ꢀPAP-12V-S  
(Note7) Parts used for thermistor output;  
ꢀ(contact︓SPHD-001T-P0.5)  
Manufacturer  
Part No.  
:
TDK Corp.  
: NTCG164BH103JT  
(Note6) Either IDC or crimp type can be used as a  
mating connector.  
(Note8) Parts used for hall element output;  
Manufacturer  
Part No.  
: Asahi Kasei EMD Corp.  
: HW-105A  
4.Timing Chart  
H
H1+  
L
H
H1-  
L
H
H2+  
L
H
H2-  
L
H
H3+  
L
H
H3-  
L
+
U
-
+
V
-
+
W
-
0
60 120 180 240 300 360  
15 30 45 60 75 90  
[deg] Electrical degree  
[deg] Mechanical degree  
0
NIDEC COPAL ELECTRONICS CORP.  
5
7
/
5. Operating Range  
(Note 9) The following graph is provided for reference only. Values are not guaranteed.  
(Note 10) Supply Voltage : DC 24 V, Environmental conditions : 23℃, Atmospheric pressure : 101.3kPa  
5.0  
4.5  
4.0  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0.0  
Operating Range  
40,000rpm  
30,000rpm  
15,000rpm  
Current40,000r/min  
Current30,000r/min  
Current15,000r/min  
0
20  
40  
60  
80  
100  
120  
140  
Air Flow [L/min]  
6.Manufacturing Code  
QRꢀCode  
Model No.,Lot No.(year of manufacture,month of manufacture,  
day of manufacture,control number),Serial Number  
:
Serial Number  
Control number  
alphabet (A - Z)  
:
Date of manufacture refer to Chart 1 below  
:
Month of manufactur refer to Chart 2 below  
:
Year of manufacture  
last digit of the year (A.D.)  
:
Chart 1】  
Date  
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9 10 11 12 13 14 15 16 17 18 19 20  
Code  
1
9
A
B
C
D
E
F
G
H
J
K
L
Date  
Code  
21 22 23 24 25 26 27 28 29 30 31  
M
N
P
Q
R
T
U
V
W
X
Y
Chart 2】  
Month  
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9 10 11 12  
Code  
1
9
O
N
D
NIDEC COPAL ELECTRONICS CORP.  
6
7
/
7.Warranty  
ꢀ7-1.Warranty Period  
Warranty period of the PRODUCT is 1 year from delivery.  
ꢀ7-2.Warranty Scope  
In case a defect is found in the PRODUCT during the above warranty period and NCEL is responsible for the defect,  
NCEL will either repair or replace the defected PRODUCT free of charge.  
(1)  
However, in the following cases, the PRODUCT will not be covered by warranty.  
Defects caused by inappropriate conditions, environments, handlings, and use which are not specified in this  
specification.  
Defects caused by your equipments and/or software.  
Defects caused by modifications and/or repairs which were not done by NCEL.  
Defects which could have been avoided if the PRODUCT was used accordingly to this specification.  
Defects which were unpredictable with the scientific or technical level of NCEL at the time of shipment.  
Defects caused by external factors such as natural hazards (fire, earthquakes, floods) or electrical surges.  
NCEL will be responsible for the PRODUCT only in which the coverage will be limited to Clause 7-2. (1). NCEL shall  
not be liable for customer's equipment damages, opportunity losses, or lost earnings caused by defects of the  
(2)  
PRODUCTS. The user shall indemnify NCEL and hold NCEL harmless from any liability or damage whatsoever arising  
out of any action not in accordance with this specification.  
ꢀ7-3.Product Application  
The PRODUCT is designed and manufactured for general industrial use for general purposes. Please do not use in  
applications such as nuclear power, aviations, railroads, or medical equipment where great effect to human lives or  
wealth are expected.  
However, if NCEL agree with the customer the usage of the PRODUCT in such applications, NCEL will warrant the  
PRODUCT in the same scope described in "7. Warranty" in this specification.  
8.Notes  
(1) All values are measured with NCEL's standard equipments unless otherwise specified.  
(2) The PRODUCT is compliant with RoHS directives which went into effect July, 2011.  
Designated hazardous substances are lead, mercury, cadmium, hexavalent chrome, brominated flame retardants  
(PBB, PBDE) and its compounds.  
(3) The PRODUCT is compliant with Directive 2006/122/EC of the European Parliament (Council Directive 76/769/EEC  
(30th amendment)) which restricts the use of PFOS.  
(4) Contents of this document may be changed without notice. The production of the PRODUCT may be discontinued  
without notice. Please confirm with your local contact before ordering.  
(5) Please check if the PRODUCT operates normally at every start-up and during operation.  
(6) Please provide safety measures to prevent damages in case of product failures.  
(7) Performance cannot be guaranteed in case the PRODUCT is used beyond the specification or the PRODUCT is  
(8) Depending on the conditions or the environment, functions or performances of the PRODUCT may not be satisfied  
when the PRODUCT is used with other equipments.  
(9) Please do not use the PRODUCT in applications to protect the body.  
(10)  
(11)  
(12)  
(13)  
Please protect the PRODUCT from condensation.  
Please use the correct supply voltage to operate the PRODUCT.  
Do not disassemble or modify the PRODUCT.  
Turn off the power immediately and stop using the PRODUCT in the following cases.  
● In case water or foreign substances get into the PRODUCT.  
● In case the PRODUCT is dropped or the housing is broken.  
● In case unusual odor, abnormal noise, or smoke are generated from the PRODUCT.  
Turn off the power of the PRODUCT and any equipment attached to the PRODUCT when putting on or taking off the  
cables.  
(14)  
NIDEC COPAL ELECTRONICS CORP.  
7
7
/
(15)  
Do not use or store in the following conditions;  
● Humid, dusty, or poorly-ventilated area.  
● Areas where the temperature is expected to rise (direct sunlight, etc.).  
● Areas with corrosive gas or flammable gas in the surrounding air.  
● Areas where vibration, shock, or rocking motion is applied directly to the PRODUCT.  
● Areas where the PRODUCTS may be splashed with water, oil, or chemicals.  
● Areas where static electricity can be built up.  
(16)  
(17)  
Please contact us if you have any questions regarding installation.  
Do not block the air inlet and outlet (2 places). Please contact us if you have any questions regarding the air inlet  
and outlet.  
(18)  
Vibration or audible noise level may change over time due to contamination of the blade. Please provide dust-proof  
constructions around the PRODUCT.  
(19)  
(20)  
(21)  
Please advise us in case the driving circuit will be designed at the customer's side.  
Please connect and don't use air inlet of this product (2 places) in series.  
Please don't use by the suction use.  

相关型号:

TF037F-2000-F

BLOWER OUTLUNE
NIDEC

TF037F-2000-P

BLOWER OUTLINE
NIDEC

TF04010100J0G

Barrier Strip Terminal Block
AMPHENOL

TF04014000J0G

Barrier Strip Terminal Block
AMPHENOL

TF04014100J0G

Barrier Strip Terminal Block
AMPHENOL

TF04014200J0G

Barrier Strip Terminal Block
AMPHENOL

TF04015200J0G

Barrier Strip Terminal Block
AMPHENOL

TF04016000J0G

Barrier Strip Terminal Block
AMPHENOL

TF04016100J0G

Barrier Strip Terminal Block
AMPHENOL

TF04019100J0G

Barrier Strip Terminal Block
AMPHENOL

TF0402B-04P-03

Single Phase EMI Filter
TDK

TF0402B-05P-01

Single Phase EMI Filter
TDK