Digital Fiber Sensors  
E3X-DA-S  
An Extensive of Standard Functions  
to Support the World's Highest Level of  
Stable Detection.  
• "GIGA RAY" Giga Power Lighting Element to create a wide variety  
of value.  
• Power turning to easily set the optimum light level.  
• Active Thereshold Control (ATC) reduces incorrect operation due to  
dust, oil, or other influences.  
• Automatic Power Control (APC) is always enabled to stabilize  
emitter power with high accuracy.  
Ordering Information  
Amplifier Units [Dimensionspage 23]  
Applicable wire-saving connector  
(sold separately)  
Model  
Connecting  
method  
Type  
Appearance  
NPN output  
PNP output  
Type  
Model  
Pre-wired  
(2 m)  
E3X-DA21-S 2M  
E3X-DA51-S 2M  
---  
---  
Standard  
models  
Master  
connector  
E3X-CN21  
E3X-CN22  
Wire-saving  
connector ✽  
E3X-DA7-S  
E3X-DA9-S  
Slave  
connector  
Pre-wired  
(2 m)  
E3X-DA21R-S 2M  
E3X-DA7R-S  
E3X-DA51R-S 2M  
E3X-DA9R-S  
---  
---  
Ultra-long-term  
APC models  
Master  
connector  
E3X-CN21  
E3X-CN22  
Wire-saving  
connector ✽  
Slave  
connector  
Pre-wired  
(2 m)  
E3X-DA21F-S 2M  
E3X-DA7F-S  
E3X-DA51F-S 2M  
E3X-DA9F-S  
---  
---  
High-speed  
response  
models  
Master  
connector  
E3X-CN11  
E3X-CN12  
Wire-saving  
connector ✽  
Slave  
connector  
An Wire-saving connector sold separately is required.  
1
E3X-DA-S  
Wire-saving connector (sold separately) Protection stickers attached [Dimensionspage 25]  
Type  
Appearance  
Cable length  
No. of conductors  
Model  
Master connector  
4
E3X-CN21  
Slave connector  
Master connector  
Slave connector  
2
3
1
E3X-CN22  
E3X-CN11  
E3X-CN12  
2 m  
Note: The E3X-CN11/12 can also be used to connect to the E3X-DA@-S (@: 7/9) or the E3X-DA@R-S (@: 7/9), but the output lines will support  
only 1 channel. Output function for channel 2 or APC alarm output function will be disabled.  
Accessories (sold separately)  
Mounting Brackets [Dimensionspage 26]  
End Plate [Dimensionspage 26]  
Appearance Model  
Appearance  
Model  
Quantity  
Quantity  
E39-L143  
1
PFP-M  
1
Product Overview  
}: Strong point of the model {: Provided ---: Not provided  
Types  
Standard models  
Ultra-long-term APC models  
High-speed response models  
Connecting  
method  
Wire-saving  
connector  
Wire-saving  
Pre-wired  
Wire-saving  
Pre-wired  
Pre-wired  
connector  
connector  
E3X-DA21-S  
E3X-DA51-S  
E3X-DA7-S  
E3X-DA9-S  
E3X-DA21R-S  
E3X-DA51R-S  
E3X-DA7R-S  
E3X-DA9R-S  
E3X-DA21F-S  
E3X-DA51F-S  
E3X-DA7F-S  
E3X-DA9F-S  
Models  
Item  
External input  
1 input  
---  
1 input  
---  
---  
Input/output  
Output  
2 outputs  
1 output and 1 APC alarm output  
1 output  
Sensing distance  
with E32-T11R  
280 to 2,000 mm  
(Depends on response time)  
140 to 1,000 mm  
(Depends on response time)  
280 mm  
(Only Super-high-speed Mode)  
Sensing distance  
with E32-D11R  
100 to 840 mm  
(Depends on response time)  
50 to 420 mm  
(Depends on response time)  
100 mm  
(Only Super-high-speed Mode)  
Performance  
Giga Power  
(GIGA RAY)  
}
{
{
(Margin: × 160)  
High-speed  
response  
{
(80 μs)  
{
(80 μs)  
}
(46 μs)  
Power tuning  
{
{
{
Automatic power  
control (APC)  
}
{
{
(Ultra-long-term APC)  
Timer  
ATC  
{
{
{
{
{
{
{
{
{
Function  
Key lock  
Easy key lock  
(switchable)  
---  
{
{
APC margin  
display  
---  
---  
{
---  
Slow-motion display  
---  
{
2
E3X-DA-S  
Ratings and Specifications  
Amplifier Units  
Type  
Standard models  
Ultra-long-term APC models  
E3X-DA -S (@: 21/51/7/9)  
High-speed response models  
Item  
Model  
E3X-DA@-S (@: 21/51/7/9)  
Red,4-element LED (625 nm)  
@
R
E3X-DA@F-S (@: 21/51/7/9)  
Light source  
(wavelength)  
Power supply voltage  
12 to 24 VDC ±10%, ripple (p-p) 10% max.  
Normal mode  
: 960 mW max. (Current consumption: 40 mA max. at 24 VDC, 80 mA max. at 12 VDC)  
Power consumption  
Power saving ECO1: 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC)  
Power saving ECO2: 600 mW max. (Current consumption: 25 mA max. at 24 VDC, 50 mA max. at 12 VDC)  
Control output /  
APC alarm output  
Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector;  
load current: 50 mA max.; residual voltage: 2 V max.  
External input 1  
No-voltage input (contact / transistor) 2  
---  
Protection circuits  
Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection  
Super-high-  
NPN output: Operate: 46  
PNP output: Operate: 51  
μ
s, Reset: 48  
s, Reset: 53  
μ
s
s
Operate or reset: 80 μs  
Operate or reset: 250 μs  
speed Mode 3  
μ
μ
High-speed  
Mode  
Re-  
sponse  
time  
Standard Mode Operate or reset: 1 ms  
---  
---  
High-resolution  
Operate or reset: 4 ms  
Mode  
Tough Mode  
Sensitivity setting  
Power tuning  
Operate or reset: 16 ms  
Teaching or manual method  
Light emission power and reception gain, digital control method  
Switchable between Single-edge and Double-edge Detection Modes.  
Single edge: Set to 250 μs, 500 μs, 1 ms, 10 ms, or 100 ms.  
Double edge: Set to 500 μs, 1 ms, 2 ms, 20 ms, or 200 ms  
Differential  
detection  
Automatic  
power control  
(APC)  
Always enabled.  
High-speed control of emission current  
Wide-range APC for the E3X-DA  
@R-S  
Select from timer disabled, OFF-delay, ON-delay, One-shot, or ON-delay + OFF-delay timer  
Timer  
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms  
increments, and 1 to 5 s set in 1-s increments)  
ATC  
Provided  
APC margin  
display  
---  
---  
Provided  
---  
Func-  
tions  
Slow-motion  
display  
Provided  
Zero reset  
Negative values can be displayed. (Threshold value is shifted.)  
Resetting  
settings  
Select from initial reset (factory defaults) or user reset (saved settings).  
Mutual  
interference  
prevention  
Possible for up to 10 units 4  
---  
ECO Mode 5  
Select from OFF (digital display lit), ECO1 (digital display dimmed), and ECO2 (digital display OFF).  
External input  
setting 1  
Select from teaching operations, power tuning, zero reset, emitter OFF, or  
ATC start.  
---  
Select from output for each channel,  
---  
Output setting  
area output, or self-diagnosis.  
Operation indicator for  
Operation indicator for  
channel 1(orange)  
APC alarm output indicator (orange) Power tuning indicator (orange)  
Operation indicator for  
channel 1(orange)  
channel 1(orange)  
Operation indicator for  
channel 2(orange)  
Indicator  
1. Only for Pre-wired models.  
2. The following details apply to inputs.  
Contact input (relay or switch)  
Non-contact input (transistor)  
ON: Shorted to 0 V (sourcing current: 1 mA max.).  
OFF: Open or shorted to Vcc.  
ON: 1.5 V max. (sourcing current: 1 mA max.)  
OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.)  
NPN  
PNP  
ON: Shorted to Vcc (sinking current: 3 mA max.).  
OFF: Open or shorted to 0 V.  
ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)  
OFF: 1.5 V max. (leakage current: 0.1 mA max.)  
3. The communications function and mutual interference prevention function are disabled if detection is set to Super-high-speed mode.  
4. Mutual interference prevention is enabled if Amplifier Units are connected together. It is also enabled in the same way if E3X-DA-S-series Units  
and E3C-LDA-series Units are used together. If power tuning is enabled, mutual interference prevention can be used for up to six units.  
5. For the E3X-DA@-S (@: 21/51/7/9), the rated sensing distance is approximately 1/2 and the incident level is approximately 1/3 of the normal  
levels when ECO mode is enabled.  
3
E3X-DA-S  
Item  
Model  
E3X-DA@-S (@: 21/51/7/9)  
E3X-DA@R-S (@: 21/51/7/9)  
E3X-DA@F-S (@: 21/51/7/9)  
Digital display  
Display orientation  
Key lock  
Select from incident level + threshold or other 6 patterns (Refer to 6. Display switch on page 17.)  
Switching between normal / reversed display is possible.  
Key lock  
Key lock / Easy key lock.  
Ambient illumination  
(Receiver side)  
Incandescent lamp: 10,000 lux max.  
Sunlight: 20,000 lux max.  
Maximum connectable  
Units  
16 (The ambient temperature specification depends on the number of connected units.)  
Operating: Groups of 1 to 2 Amplifiers: 25 to 55°C  
Groups of 3 to 10 Amplifiers: 25 to 50°C  
Groups of 11 to 16 Amplifiers: 25 to 45°C  
Ambient temperature  
range  
Storage: 30 to 70°C (with no icing or condensation)  
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)  
Insulation resistance  
Dielectric strength  
Vibration resistance  
Shock resistance  
20 MΩ min. (at 500 VDC)  
1,000 VAC at 50/60 Hz for 1 minute  
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y and Z directions  
Destruction: 500 m/s2 for 3 times each in X, Y and Z directions  
IEC 60529 IP50 (with Protective Cover attached)  
Pre-wired (standard length 2 m) or Wire-saving connector  
Pre-wired models: Approx. 100 g, Wire-saving connector models: Approx. 55 g  
Polybutylene terephthalate (PBT)  
Degree of protection  
Connection method  
Weight (packed state)  
Case  
Materials  
Cover  
Polycarbonate (PC)  
Accessories  
Instruction Manual  
Wire-saving connectors  
Item  
Model  
E3X-CN21/22/11  
E3X-CN12  
Rated current  
Rated voltage  
2.5 A  
50 V  
20 mΩ max. (20 mVDC max., 100 mA max.)  
(The figure is for connection to the Amplifier Unit and the adjacent connector. It does not include the conductor  
resistance of the cable.)  
Contact resistance  
No. of insertions  
Destruction: 50 times  
(The figure for the number of insertions is for connection to the Amplifier Unit and the adjacent connector.)  
Housing  
Contacts  
Polybutylene terephthalate (PBT)  
Materials  
Phosphor bronze / gold-plated nickel  
Weight (packed state)  
Approx. 55 g  
Approx. 25 g  
4
E3X-DA-S  
Sensing Distance  
E3X-DA@-S (@: 21/51/7/9) ƒ E3X-DA@F-S(@: 21/51/7/9)  
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Screw-shaped model  
Sensing distance (unit: mm)  
Sensing  
Size  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Model  
E32-T21R 2M  
Tough mode  
method  
mode  
speed mode  
M3  
Straight  
450  
2,000  
2,000  
2,800  
4,000 ✽  
110  
300  
1,400  
1,400  
2,000  
3,400  
80  
250  
150  
700  
700  
60  
Right angle  
E32-T11N 2M  
E32-T11R 2M  
E32-TC200 2M  
E32-T11L 2M  
E32-C31N 2M  
E32-D21R 2M  
E32-C31 2M  
1,000  
1,000  
1,550  
2,700  
50  
280  
280  
400  
700  
14  
Through-  
beam  
models  
M4  
Straight  
Right angle  
Straight  
1,000  
1,740  
46  
M3  
M4  
140  
100  
60  
40  
16  
330  
240  
150  
60  
100  
40  
44  
E32-D211R 2M  
E32-D11N 2M  
E32-C11N 2M  
E32-D11R 2M  
E32-DC200 2M  
E32-CC200 2M  
E32-D11L 2M  
140  
100  
16  
840  
600  
350  
350  
350  
600  
600  
800  
240  
320  
240  
400  
400  
520  
100  
100  
100  
180  
180  
220  
Reflective  
models  
Right angle  
Straight  
780  
560  
840  
600  
M6  
1,400  
1,400  
1,820  
1,000  
1,000  
1,300  
The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.  
Fiber Unit  
Flat model  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Sensing distance (unit: mm)  
Sensing  
method  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Size  
Model  
E32-T15XR 2M  
Tough mode  
mode  
speed mode  
Standard  
Small  
2,000  
450  
750  
170  
750  
170  
840  
140  
200  
40  
1,400  
300  
550  
120  
550  
120  
600  
100  
140  
28  
1,000  
700  
150  
260  
50  
280  
60  
100  
20  
100  
20  
100  
16  
24  
4
Top view  
Side view  
Flat view  
Top view  
Side view  
Flat view  
E32-T25XR 2M  
E32-T15YR 2M  
E32-T25YR 2M  
E32-T15ZR 2M  
E32-T25ZR 2M  
E32-D15XR 2M  
E32-D25XR 2M  
E32-D15YR 2M  
E32-D25YR 2M  
E32-D15ZR 2M  
E32-D25ZR 2M  
250  
450  
100  
450  
100  
350  
60  
Through-  
beam  
models  
Standard  
Small  
Standard  
Small  
260  
50  
Standard  
Small  
240  
40  
Standard  
Small  
100  
16  
52  
Reflective  
models  
10  
Standard  
Small  
200  
40  
140  
28  
100  
16  
52  
24  
4
10  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Cylindrical model  
Sensing distance (unit: mm)  
Sensing  
method  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Size  
Model  
Tough mode  
mode  
speed mode  
φ1  
φ3  
E32-T223R 2M  
E32-T12R 2M  
E32-T24R 2M  
E32-T14LR 2M  
E32-D22B 2M  
E32-D32 2M  
450  
2,000  
170  
750  
140  
330  
140  
700  
70  
300  
1,400  
120  
550  
100  
240  
100  
500  
52  
250  
150  
700  
50  
60  
280  
20  
Top view  
Through-  
beam  
models  
1,000  
100  
450  
60  
φ1  
Side view  
Top view  
Side view  
φ3  
260  
40  
100  
16  
44  
φ1.5  
φ2  
150  
60  
100  
40  
E32-D22R 2M  
E32-D32L 2M  
E32-D24R 2M  
E32-D14LR 2M  
16  
90  
8
Reflective  
models  
φ3  
300  
30  
200  
20  
φ2  
φ6  
220  
160  
100  
60  
28  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Model equipped with sleeve  
Sensing distance (unit: mm)  
Sensing  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Sleeve size  
method  
Mounting size  
Model  
Tough mode  
mode  
speed mode  
φ0.25 × 5  
E32-T333-S5 1M  
E32-T33 1M  
35  
150  
450  
2,000  
14  
25  
110  
300  
1,400  
10  
20  
12  
50  
8
20  
60  
280  
2
φ3  
Through-  
beam  
models  
φ0.5 × 40  
90  
250  
1,000  
6
φ0.9 × 40  
M3  
M4  
φ2  
E32-TC200F4R 2M  
E32-TC200BR 2M  
E32-D331 2M  
150  
700  
4
φ1.2 × 90  
φ0.5 × 15  
φ0.8 × 15  
φ1.2 × 40  
φ2.5 × 90  
φ3  
E32-D33 2M  
70  
50  
30  
20  
8
Reflective  
models  
M3  
M6  
E32-DC200F4R 2M  
E32-DC200BR 2M  
140  
840  
100  
600  
60  
40  
16  
100  
350  
240  
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).  
5
E3X-DA-S  
E3X-DA@-S (@: 21/51/7/9) ƒ E3X-DA@F-S(@: 21/51/7/9)  
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Movable section (Flexibility)  
Sensing distance (unit: mm)  
Sensing  
Type  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Size  
Model  
Tough mode  
method  
mode  
speed mode  
M3  
M4  
E32-T21 2M  
E32-T11 2M  
680  
2,500  
680  
480  
1,800  
480  
400  
220  
900  
220  
900  
900  
170  
40  
90  
360  
90  
Screw-shaped  
model  
1,350  
400  
1,350  
1,350  
300  
60  
Through-  
Cylindrical  
beam  
φ1.5  
φ3  
Standard  
Small  
M3  
E32-T22B 2M  
E32-T12B 2M  
E32-T15XB 2M  
E32-T25XB 2M  
E32-D21 2M  
model  
2,500  
2,500  
500  
1,800  
1,800  
360  
360  
360  
70  
models  
Flat model  
140  
100  
16  
Screw-shaped  
model  
M4  
E32-D21B 2M  
E32-D11 2M  
300  
220  
140  
350  
60  
90  
40  
M6  
840  
600  
240  
40  
100  
16  
Reflective  
φ1.5  
φ3  
Standard  
Small  
E32-D22B 2M  
E32-D221B 2M  
E32-D15XB 2M  
E32-D25XB 2M  
140  
100  
Cylindrical  
models  
model  
300  
220  
140  
350  
100  
90  
40  
840  
600  
240  
60  
100  
30  
Flat model  
240  
170  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Heat-resistance model  
Sensing distance (unit: mm)  
Sensing  
method  
Operating  
temperature  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Lens  
Model  
E32-T51R 2M  
E32-T51R 2M + E39-F1  
Tough mode  
mode  
speed mode  
---  
1,600  
4,000 ✽  
4,000 ✽  
2,800  
4,000 ✽  
4,000 ✽  
840  
1,100  
4,000 ✽  
4,000 ✽  
2,000  
4,000 ✽  
4,000 ✽  
600  
800  
560 225  
100°C  
150°C  
Lens  
4,000 ✽  
4,000 ✽  
1,500  
4,000 ✽  
4,000 ✽  
450  
3,900  
4,000 ✽  
1,000  
2,300  
4,000 ✽  
300  
1,500  
4,000 ✽  
400  
High-power lens E32-T51R 2M + E39-F16  
---  
E32-T51 2M  
Lens  
E32-T51 2M + E39-F1-33  
1,400  
4,000 ✽  
120  
Through-  
beam  
models  
High-power lens E32-T51 2M + E39-F16  
E32-T54 2M  
---  
E32-T81R-S 2M  
E32-T61-S 2M  
1,000  
1,680  
4,000 ✽  
1,680  
4,000 ✽  
670  
720  
550  
360  
140  
200°C  
350°C  
1,200  
4,000 ✽  
1,200  
4,000 ✽  
480  
900  
4,000 ✽  
600  
240  
Lens  
---  
E32-T61-S 2M + E39-F1  
E32-T61-S 2M  
4,000 ✽  
1,800  
240  
900  
600  
High-power lens E32-T61-S 2M + E39-F16  
E32-D51R 2M  
4,000 ✽  
280  
4,000 ✽  
190  
3,100  
80  
100°C  
150°C  
200°C  
350°C  
400°C  
E32-D51 2M  
1,120  
420  
800  
450  
320  
144  
Reflective  
models  
---  
E32-D81R 2M  
E32-D61 2M  
E32-D73 2M  
300  
180  
120  
54  
420  
300  
180  
120  
54  
280  
200  
120  
80  
36  
The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Chemical-resistance / Oil-resistance model  
Sensing distance (unit: mm)  
Sensing  
Type  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Model  
E32-T12F 2M  
Tough mode  
method  
mode  
4,000 1  
speed mode  
φ5  
φ7.2  
φ5  
4,000 1  
4,000 1  
4,000 1  
4,000 1  
4,000 1  
4,000 1  
1,600  
E32-T11F 2M  
2,600  
1,000  
E32-T51F 2M  
4,000 1  
3,600  
1,000  
1,800  
2,800  
800  
1,800  
700  
200  
360  
Heat-resistance model  
Through-  
beam  
models  
φ5  
Side view  
E32-T14F 2M  
E32-T11U 2M  
1,400  
500  
900  
M4  
2,500  
1,350  
Chemical-resistance cable  
M4  
E32-T11NU 2M  
E32-D12F 2M  
E32-D14F 2M  
1,440  
--- 2  
--- 2  
1,040  
320  
800  
190  
80  
520  
130  
60  
200  
60  
Right angle Chemical-resistance cable  
φ6  
φ7  
Reflective  
Side view  
models  
140  
20  
M6  
E32-D11U 2M  
840  
600  
350  
240  
100  
Chemical-resistance cable  
1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.  
2. Even if there is no sensing object, the sensor will detect light that is reflected by the fluororesin.  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Vacuum-resistance model  
Sensing distance (unit: mm)  
Sensing Operating ambient  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Model  
E32-T51V 1M  
Tough mode  
method  
temperature  
120°C  
mode  
speed mode  
720  
3,780  
580  
520  
2,700  
420  
400  
260  
100  
520  
70  
Top view  
Through-  
beam  
E32-T51V 1M + E39-F1V  
E32-T54V 1M  
2,000  
250  
1,360  
200  
models  
Right angle  
200°C  
E32-T84SV 1M  
1,760  
1,250  
950  
640  
260  
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).  
6
E3X-DA-S  
E3X-DA@-S (@: 21/51/7/9) ƒ E3X-DA@F-S(@: 21/51/7/9)  
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Long distance / Dust resistance (High-power),  
Detection through gaps (Narrow vision field)  
Sensing distance (unit: mm)  
Sensing  
method  
Sensing direction /  
Lens type  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Type  
Model  
E32-T17L 10M  
E32-T14 2M  
E32-T11N 2M + E39-F1  
Tough mode  
mode  
speed mode  
8,000  
1,800  
2,000  
3,600  
2,000  
3,600  
200  
Top view  
Side view  
High-power  
20,000 1  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
1,450  
4,000 2  
4,000 2  
2,350  
4,000 2  
4,000 2  
2,300  
4,000 2  
4,000 2  
2,300  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
1,000  
4,000 2  
4,000 2  
1,680  
20,000 1  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
1,040  
4,000 2  
4,000 2  
1,680  
4,000 2  
4,000 2  
1,640  
4,000 2  
4,000 2  
1,640  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
720  
4,000 2  
4,000 2  
1,200  
20,000 1  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
800  
4,000 2  
4,000 2  
1,400  
4,000 2  
4,000 2  
1,320  
4,000 2  
4,000 2  
1,320  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
550  
4,000 2  
4,000 2  
900  
20,000 1  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
500  
High-power  
(integrated unit)  
Ultrahigh-power E32-T11N 2M + E39-F16  
High-power E32-T11R 2M + E39-F1  
Ultrahigh-power E32-T11R 2M + E39-F16  
Side view  
E32-T11R 2M + E39-F2  
E32-TC200 2M + E39-F1  
High-power  
4,000 2  
4,000 2  
900  
3,000  
4,000 2  
320  
Ultrahigh-power E32-TC200 2M + E39-F16  
Side view  
E32-TC200 2M + E39-F2  
E32-T11 2M + E39-F1  
High-power  
4,000 2  
4,000 2  
860  
1,860  
4,000 2  
320  
Ultrahigh-power E32-T11 2M + E39-F16  
Through-  
beam  
models  
Side view  
E32-T11 2M + E39-F2  
E32-T11U 2M + E39-F1  
High-power  
(with lens unit)  
High-power  
4,000 2  
4,000 2  
860  
1,860  
4,000 2  
320  
Ultrahigh-power E32-T11U 2M + E39-F16  
Side view  
E32-T11U 2M + E39-F2  
E32-T11NU 2M + E39-F1  
High-power  
2,600  
4,000 2  
1,000  
2,800  
1,000  
1,800  
140  
Ultrahigh-power E32-T11NU 2M + E39-F16  
High-power E32-T81R-S 2M + E39-F1  
Ultrahigh-power E32-T81R-S 2M + E39-F16  
2,700  
4,000 2  
360  
Side view  
E32-T81R-S 2M + E39-F2  
E32-T61-S 2M + E39-F1  
High-power  
4,000 2  
4,000 2  
600  
1,800  
3,100  
240  
Ultrahigh-power E32-T61-S 2M + E39-F16  
Side view  
Top view  
Side view  
E32-T61-S 2M + E39-F2  
E32-T22S 2M  
4,000 2  
4,000 2  
4,000 2  
3,800  
2,500  
1,000  
700  
Narrow vision field  
(aperture angle: 4  
°)  
E32-T24S 2M  
3,500  
2,600  
1,740  
Reflective  
models  
High-power  
Top view  
E32-D16 2M  
40 to 2,800  
40 to 2,000  
40 to 1,400  
40 to 900  
40 to 480  
1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.  
2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Minute object detection (Small-spot model)  
Sensing distance (unit: mm)  
Sensing Spot diameter  
Focal length  
(mm)  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
mode speed mode  
Model  
Tough mode  
method  
(mm)  
φ
0.1 to 0.6  
(Variable)  
6 to 15  
E32-C42 1M + E39-F3A  
E32-C42 1M + E39-F17  
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm  
Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm  
φ
0.3 to 1.6  
10 to 30  
(Variable)  
5
7
E32-C42S 1M  
Spot diameter of 0.1 mm at 5 mm  
Spot diameter of 0.1 mm at 7 mm  
Spot diameter of 0.2 mm at 17 mm  
Spot diameter of 0.5 mm at 7 mm  
Spot diameter of 0.5 mm at 17 mm  
φ0.1  
φ0.2  
φ0.5  
E32-C41 1M + E39-F3A-5  
E32-C41 1M + E39-F3B  
E32-C31 2M + E39-F3A-5  
E32-C31 2M + E39-F3B  
17  
7
Reflective  
models  
17  
Spot diameter of 6 mm at 50 mm  
Sensing distance in all mode (40 to 100 mm)  
φ6  
50  
E32-L15 2M  
φ4  
0 to 20  
E32-C31 2M + E39-F3C  
Spot diameter of 4 mm max. at 0 to 20 mm  
Parallel light  
E32-C11N 2M + E39-F18  
E32-CC200 2M + E39-F18  
Spot diameter of 3 mm at 50 mm  
Spot diameter of 3 mm at 50 mm  
φ3  
50  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Area-sensing (Area beam)  
Sensing distance (unit: mm)  
Sensing  
Area range  
method  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Model  
E32-T16PR 2M  
Tough mode  
mode  
speed mode  
Side view  
Flat view  
3,100  
2,750  
4,000 ✽  
2,200  
2,000  
3,400  
1,700  
1,120  
440  
380  
680  
Through-  
11 mm  
beam  
E32-T16JR 2M  
E32-T16WR 2M  
1,500  
2,600  
960  
models  
30 mm  
11 mm  
1,700  
Side view  
Reflective  
models  
E32-D36P1 2M  
700  
500  
300  
200  
90  
The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.  
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).  
7
E3X-DA-S  
E3X-DA@-S (@: 21/51/7/9) ƒ E3X-DA@F-S(@: 21/51/7/9)  
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Detection without background interference (Convergent-reflective)  
Sensing distance (unit: mm)  
Sensing  
method  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Size  
Model  
E32-L16-N 2M ✽  
E32-L24S 2M ✽  
E32-L25L 2M ✽  
E32-L24L 2M ✽  
Tough mode  
mode  
speed mode  
Standard  
Small  
0 to 15  
0 to 12  
Flat view  
0 to 4  
Reflective  
models  
Top view  
Flat view  
5.4 to 9 (center 7.2)  
2 to 6 (center 4)  
---  
If operation is affected by the background, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Detection of transparent objects (Retro-reflective)  
Sensing distance (unit: mm)  
Sensing  
Type  
High-resolution  
Standard  
mode  
High-speed Super-high-  
Model  
Tough mode  
method  
mode  
mode  
speed mode  
Square  
Small  
E32-R16 5M + E39-R1 (attached) 1  
E32-R21 2M + E39-R3 (attached) 1  
E32-C31 2M + E39-F3R+E39-RP37 1  
E32-C31 2M + E39-F3R+E39-RSP1 1  
150 to 1,500  
10 to 250  
Retrore-  
flective  
models  
250  
450  
200  
300  
---  
Film detection 2  
100  
1. When using a highly reflective object, light reflected from the object may affect the sensor.  
2. The effect may be small due to the film. Also, stable detection may not be possible when there is a sensing object directly in front of the Lens  
Unit. Be sure to check operation in advance.  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
FPD / Semiconductor / Solar battery industry  
Sensing distance (unit: mm)  
Sensing  
method  
Operating  
temperature  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Application  
Model  
E32-L16-N 2M ✽  
E32-L16-N 2M ✽  
E32-A08 2M ✽  
E32-A08H2 3M ✽  
E32-A09 2M  
Tough mode  
mode  
speed mode  
Glass detection  
0 to 15  
0 to 12  
0 to 12  
---  
70°C  
0 to 15  
10 to 20  
10 to 20  
15 to 38  
15 to 38  
20 to 30  
Glass substrate  
alignment  
300°C  
70°C  
---  
---  
Reflective  
models  
Glass substrate  
mapping  
150°C  
300°C  
60°C  
E32-A09H 2M  
E32-A09H2 2M  
E32-L11FP 5M  
E32-L12FS 5M  
E32-L11FS 5M  
E32-A03 2M  
---  
---  
8 to 20 mm from end of lens (recommended: 11 mm)  
8 to 20 mm from end of lens (recommended: 11 mm)  
8 to 20 mm from end of lens (recommended: 11 mm)  
WET process  
70°C  
85°C  
3,220  
3,220  
1,280  
1,280  
2,300  
2,300  
920  
1,780  
1,780  
680  
1,200  
1,200  
450  
500  
500  
200  
200  
Through-  
beam  
models  
E32-A03-1 2M  
E32-A04 2M  
Wafer mapping  
70°C  
E32-A04-1 2M  
920  
680  
450  
If operation is affected by the background, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.  
Fiber Unit  
Amplifier Unit  
E3X-DA@-S (@: 21/51/7/9)  
Liquid-level detection model  
Sensing distance (unit: mm)  
Sensing  
method  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
mode speed mode  
Pipe diameter  
No limit  
Model  
E32-D36T 5M 1, 2  
E32-L25T 2M  
Tough mode  
Applicable pipe: Transparent (no restriction on diameter)  
Mounted to pipe  
Wet  
Reflective  
models  
Applicable pipe: Transparent pipe with diameter of 8 to 10 mm,  
recommended pipe wall thickness: 1 mm  
φ8 to 10 mm  
---  
E32-D82F1 4M 1  
Wet model  
1. If a high level of light is received, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.  
2. In Tough mode, detection may not be possible depending on the pipe diameter. Check operation with the pipe that will be used.  
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).  
8
E3X-DA-S  
E3X-DA@R-S (@: 21/51/7/9)  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Screw-shaped model  
Sensing distance (unit: mm)  
Sensing  
method  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Size  
Model  
E32-T21R 2M  
Tough mode  
mode  
speed mode  
M3  
Straight  
220  
1,000  
1,000  
1,400  
2,000  
55  
160  
700  
700  
1,000  
1,700  
40  
130  
75  
350  
350  
500  
870  
23  
30  
140  
140  
200  
350  
7
Right angle  
E32-T11N 2M  
E32-T11R 2M  
E32-TC200 2M  
E32-T11L 2M  
E32-C31N 2M  
E32-D21R 2M  
E32-C31 2M  
500  
530  
760  
1,350  
25  
Through-  
beam  
models  
M4  
Straight  
Right angle  
Straight  
M3  
M4  
70  
50  
30  
20  
8
165  
70  
120  
50  
75  
50  
22  
E32-D211R 2M  
E32-D11N 2M  
E32-C11N 2M  
E32-D11R 2M  
E32-DC200 2M  
E32-CC200 2M  
E32-D11L 2M  
30  
20  
8
420  
390  
420  
700  
700  
910  
300  
280  
300  
500  
500  
650  
175  
175  
170  
300  
300  
400  
120  
160  
120  
200  
200  
260  
50  
50  
50  
90  
90  
110  
Reflective  
models  
Right angle  
Straight  
M6  
Fiber Unit  
Flat model  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Sensing distance (unit: mm)  
Sensing  
method  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Size  
Model  
Tough mode  
mode  
speed mode  
Standard  
Small  
E32-T15XR 2M  
E32-T25XR 2M  
E32-T15YR 2M  
E32-T25YR 2M  
E32-T15ZR 2M  
E32-T25ZR 2M  
E32-D15XR 2M  
E32-D25XR 2M  
E32-D15YR 2M  
E32-D25YR 2M  
E32-D15ZR 2M  
E32-D25ZR 2M  
1,000  
220  
370  
85  
700  
160  
270  
60  
530  
350  
75  
130  
25  
130  
25  
120  
20  
26  
5
140  
30  
50  
10  
50  
10  
50  
8
Top view  
Side view  
Flat view  
Top view  
Side view  
Flat view  
130  
210  
50  
210  
50  
170  
30  
40  
8
Through-  
beam  
models  
Standard  
Small  
Standard  
Small  
370  
85  
270  
60  
Standard  
Small  
420  
70  
300  
50  
Standard  
Small  
100  
20  
70  
12  
2
Reflective  
models  
14  
Standard  
Small  
100  
20  
70  
40  
8
26  
5
12  
2
14  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Cylindrical model  
Sensing distance (unit: mm)  
Sensing  
method  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Size  
Model  
Tough mode  
mode  
speed mode  
φ1  
φ3  
E32-T223R 2M  
E32-T12R 2M  
E32-T24R 2M  
E32-T14LR 2M  
E32-D22B 2M  
E32-D32 2M  
220  
1,000  
85  
160  
700  
60  
130  
75  
350  
25  
30  
140  
10  
50  
8
Top view  
Through-  
beam  
models  
530  
50  
φ1  
Side view  
Top view  
Side view  
φ3  
370  
70  
270  
50  
210  
30  
130  
20  
φ1.5  
φ2  
160  
70  
120  
50  
75  
50  
22  
8
E32-D22R 2M  
E32-D32L 2M  
E32-D24R 2M  
E32-D14LR 2M  
30  
20  
Reflective  
models  
φ3  
350  
35  
250  
26  
150  
15  
100  
10  
45  
4
φ2  
φ6  
110  
80  
45  
30  
14  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Model equipped with sleeve  
Sensing distance (unit: mm)  
Sensing  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Sleeve size  
method  
Mounting size  
Model  
Tough mode  
mode  
speed mode  
φ0.25 × 5  
E32-T333-S5 1M  
E32-T33 1M  
17  
75  
12  
55  
10  
6
25  
4
10  
30  
140  
0.8  
4
φ3  
Through-  
beam  
models  
φ0.5 × 40  
45  
130  
530  
3
φ0.9 × 40  
M3  
M4  
φ2  
E32-TC200F4R 2M  
E32-TC200BR 2M  
E32-D331 2M  
220  
1,000  
7
160  
700  
5
75  
φ1.2 × 90  
φ0.5 × 15  
350  
2
φ0.8 × 15  
φ1.2 × 40  
φ2.5 × 90  
φ3  
E32-D33 2M  
35  
25  
16  
10  
Reflective  
models  
M3  
M6  
E32-DC200F4R 2M  
E32-DC200BR 2M  
70  
50  
30  
20  
8
420  
300  
170  
120  
50  
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).  
9
E3X-DA-S  
E3X-DA@R-S (@: 21/51/7/9)  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Movable section (Flexibility)  
Sensing distance (unit: mm)  
Sensing  
Type  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Size  
Model  
Tough mode  
method  
mode  
speed mode  
M3  
M4  
φ1.5  
φ3  
Standard  
Small  
M3  
E32-T21 2M  
E32-T11 2M  
340  
1,250  
340  
240  
900  
240  
900  
900  
180  
50  
200  
110  
450  
110  
450  
450  
85  
45  
180  
45  
180  
180  
35  
8
Screw-shaped  
model  
680  
200  
680  
680  
150  
30  
Through-  
Cylindrical  
beam  
E32-T22B 2M  
E32-T12B 2M  
E32-T15XB 2M  
E32-T25XB 2M  
E32-D21 2M  
model  
1,250  
1,250  
250  
models  
Flat model  
70  
20  
Screw-shaped  
model  
M4  
E32-D21B 2M  
E32-D11 2M  
150  
110  
300  
50  
70  
45  
20  
50  
8
M6  
420  
170  
30  
120  
20  
Reflective  
models  
φ1.5  
φ3  
Standard  
Small  
E32-D22B 2M  
E32-D221B 2M  
E32-D15XB 2M  
E32-D25XB 2M  
70  
Cylindrical  
model  
150  
110  
300  
85  
70  
45  
20  
50  
15  
420  
170  
50  
120  
30  
Flat model  
120  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Heat-resistance model  
Sensing distance (unit: mm)  
Sensing  
method  
Operating  
temperature  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Lens  
Model  
E32-T51R 2M  
E32-T51R 2M + E39-F1  
Tough mode  
mode  
speed mode  
110  
760  
1,400  
200  
700  
2,600  
60  
---  
800  
4,000 ✽  
4,000 ✽  
1,400  
4,000 ✽  
4,000 ✽  
420  
560  
3,900  
4,000 ✽  
1,000  
3,400  
4,000 ✽  
300  
425  
280  
100°C  
150°C  
Lens  
2,900  
4,000 ✽  
760  
1,900  
3,600  
500  
High-power lens E32-T51R 2M + E39-F16  
---  
E32-T51 2M  
Lens  
E32-T51 2M + E39-F1-33  
2,660  
4,000 ✽  
230  
1,150  
4,000 ✽  
150  
Through-  
beam  
models  
High-power lens E32-T51 2M + E39-F16  
E32-T54 2M  
---  
E32-T81R-S 2M  
E32-T61-S 2M  
500  
360  
280  
180  
70  
200°C  
350°C  
840  
4,000 ✽  
600  
4,000 ✽  
450  
300  
120  
900  
120  
1,500  
40  
Lens  
---  
E32-T61-S 2M + E39-F1  
E32-T61-S 2M  
3,400  
2,200  
300  
840  
600  
450  
High-power lens E32-T61-S 2M + E39-F16  
E32-D51R 2M  
4,000 ✽  
330  
4,000 ✽  
240  
4,000 ✽  
135  
3,900  
95  
100°C  
150°C  
200°C  
350°C  
400°C  
E32-D51 2M  
560  
400  
230  
160  
72  
Reflective  
models  
---  
E32-D81R 2M  
E32-D61 2M  
E32-D73 2M  
210  
150  
90  
60  
27  
210  
150  
90  
60  
27  
140  
100  
60  
40  
18  
The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Chemical-resistance / Oil-resistance model  
Sensing distance (unit: mm)  
Sensing  
Type  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Model  
E32-T12F 2M  
Tough mode  
method  
mode  
speed mode  
φ5  
φ7.2  
φ5  
4,000 1  
3,500  
4,000 1  
3,000  
2,000  
800  
E32-T11F 2M  
2,500  
2,000  
1,300  
900  
520  
E32-T51F 2M  
2,500  
700  
1,800  
500  
1,400  
350  
100  
180  
Heat-resistance model  
Through-  
beam  
models  
φ5  
Side view  
E32-T14F 2M  
E32-T11U 2M  
400  
680  
250  
450  
M4  
1,250  
900  
Chemical-resistance cable  
M4  
E32-T11NU 2M  
E32-D12F 2M  
E32-D14F 2M  
720  
--- 2  
--- 2  
520  
160  
70  
400  
95  
260  
65  
100  
30  
Right angle Chemical-resistance cable  
φ6  
φ7  
Reflective  
Side view  
models  
40  
30  
10  
M6  
E32-D11U 2M  
420  
300  
170  
120  
50  
Chemical-resistance cable  
1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.  
2. The sensor will detect light even if there is no sensing object, and so Tough Mode cannot be used.  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Vacuum-resistance model  
Sensing distance (unit: mm)  
Sensing Operating ambient  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Model  
E32-T51V 1M  
Tough mode  
method  
temperature  
120°C  
mode  
speed mode  
360  
1,890  
290  
260  
1,350  
210  
200  
130  
680  
100  
320  
50  
260  
35  
Top view  
Through-  
beam  
E32-T51V 1M + E39-F1V  
E32-T54V 1M  
1,000  
130  
models  
Right angle  
200°C  
E32-T84SV 1M  
880  
630  
480  
130  
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).  
10  
E3X-DA-S  
E3X-DA@R-S (@: 21/51/7/9)  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Long distance / Dust resistance (High-power),  
Detection through gaps (Narrow vision field)  
Sensing distance (unit: mm)  
Sensing  
method  
Sensing direction /  
Lens type  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Type  
Model  
E32-T17L 10M  
E32-T14 2M  
E32-T11N 2M + E39-F1  
Tough mode  
mode  
speed mode  
4,000  
900  
Top view  
Side view  
High-power  
20,000 1  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
725  
4,000 2  
4,000 2  
1,170  
4,000 2  
4,000 2  
1,150  
4,000 2  
4,000 2  
1,150  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
500  
4,000 2  
4,000 2  
840  
20,000 1  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
4,000 2  
520  
4,000 2  
4,000 2  
840  
4,000 2  
4,000 2  
820  
4,000 2  
4,000 2  
820  
20,000 1  
3,400  
3,700  
4,000 2  
3,700  
4,000 2  
400  
4,000 2  
4,000 2  
700  
10,000  
High-power  
(integrated unit)  
2,250  
2,400  
4,000 2  
2,400  
4,000 2  
250  
970  
Ultrahigh-power E32-T11N 2M + E39-F16  
High-power E32-T11R 2M + E39-F1  
Ultrahigh-power E32-T11R 2M + E39-F16  
1,800  
970  
1,800  
100  
Side view  
E32-T11R 2M + E39-F2  
E32-TC200 2M + E39-F1  
High-power  
2,600  
4,000 2  
450  
1,500  
4,000 2  
160  
Ultrahigh-power E32-TC200 2M + E39-F16  
Side view  
E32-TC200 2M + E39-F2  
E32-T11 2M + E39-F1  
High-power  
3,600  
4,000 2  
660  
2,300  
4,000 2  
430  
930  
Ultrahigh-power E32-T11 2M + E39-F16  
2,300  
160  
Through-  
beam  
models  
Side view  
E32-T11 2M + E39-F2  
E32-T11U 2M + E39-F1  
High-power  
(with lens unit)  
High-power  
3,600  
4,000 2  
660  
2,300  
4,000 2  
430  
930  
Ultrahigh-power E32-T11U 2M + E39-F16  
2,300  
160  
Side view  
E32-T11U 2M + E39-F2  
E32-T11NU 2M + E39-F1  
High-power  
2,600  
4,000 2  
2,000  
4,000 2  
2,100  
3,600  
280  
1,300  
3,300  
1,300  
2,300  
180  
500  
Ultrahigh-power E32-T11NU 2M + E39-F16  
High-power E32-T81R-S 2M + E39-F1  
Ultrahigh-power E32-T81R-S 2M + E39-F16  
1,300  
520  
2,650  
4,000 2  
360  
4,000 2  
4,000 2  
600  
900  
Side view  
E32-T81R-S 2M + E39-F2  
E32-T61-S 2M + E39-F1  
70  
High-power  
3,400  
4,000 2  
450  
2,200  
3,900  
300  
900  
Ultrahigh-power E32-T61-S 2M + E39-F16  
1,500  
120  
Side view  
Top view  
Side view  
E32-T61-S 2M + E39-F2  
E32-T22S 2M  
3,500  
2,500  
1,900  
1,300  
1,250  
870  
500  
Narrow vision field  
(aperture angle: 4  
°)  
E32-T24S 2M  
2,400  
1,750  
350  
Reflective  
models  
High-power  
Top view  
E32-D16 2M  
40 to 1,400  
40 to 1,000  
40 to 700  
40 to 450  
40 to 240  
1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.  
2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Minute object detection (Small-spot model)  
Sensing distance (unit: mm)  
Sensing Spot diameter  
Focal length  
(mm)  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
mode speed mode  
Model  
Tough mode  
method  
(mm)  
φ
0.1 to 0.6  
(Variable)  
6 to 15  
E32-C42 1M + E39-F3A  
E32-C42 1M + E39-F17  
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm  
Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm  
φ
0.3 to 1.6  
10 to 30  
(Variable)  
5
7
E32-C42S 1M  
Spot diameter of 0.1 mm at 5 mm  
Spot diameter of 0.1 mm at 7 mm  
Spot diameter of 0.2 mm at 17 mm  
Spot diameter of 0.5 mm at 7 mm  
Spot diameter of 0.5 mm at 17 mm  
φ0.1  
φ0.2  
φ0.5  
E32-C41 1M + E39-F3A-5  
E32-C41 1M + E39-F3B  
E32-C31 2M + E39-F3A-5  
E32-C31 2M + E39-F3B  
17  
7
Reflective  
models  
17  
Spot diameter of 6 mm at 50 mm  
Sensing distance in all mode (40 to 100 mm)  
φ6  
50  
E32-L15 2M  
φ4  
0 to 20  
E32-C31 2M + E39-F3C  
E32-C11N 2M + E39-F18  
Spot diameter of 4 mm max. at 0 to 20 mm  
Parallel light  
Spot diameter of 3 mm at 50 mm  
Spot diameter of 3 mm at 50 mm  
φ3  
50  
E32-CC200 2M  
+
E39-F18  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Area-sensing (Area beam)  
Sensing distance (unit: mm)  
Sensing  
Area range  
method  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Model  
E32-T16PR 2M  
Tough mode  
mode  
speed mode  
Side view  
Flat view  
1,550  
1,370  
2,000  
1,100  
980  
840  
560  
480  
850  
220  
190  
340  
Through-  
11mm  
beam  
E32-T16JR 2M  
E32-T16WR 2M  
750  
models  
30mm  
1,700  
1,300  
Side view  
Reflective  
11mm  
E32-D36P1 2M  
350  
250  
150  
100  
45  
models  
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).  
11  
E3X-DA-S  
E3X-DA@R-S (@: 21/51/7/9)  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Detection without background interference (Convergent-reflective)  
Sensing distance (unit: mm)  
Sensing  
method  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Size  
Model  
E32-L16-N 2M ✽  
E32-L24S 2M ✽  
E32-L25L 2M ✽  
E32-L24L 2M ✽  
Tough mode  
mode  
speed mode  
Standard  
Small  
0 to 15  
0 to 12  
Flat view  
0 to 4  
Reflective  
models  
Top view  
Flat view  
5.4 to 9 (center 7.2)  
2 to 6 (center 4)  
---  
If operation is affected by the background, perform power tuning to reduce the amount of light that is received.  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Sensing distance (unit: mm)  
Detection of transparent objects (Retro-reflective)  
Sensing  
Type  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Model  
Tough mode  
method  
mode  
speed mode  
Square  
Small  
E32-R16 5M + E39-R1 (attached) 1  
E32-R21 2M + E39-R3 (attached) 1  
E32-C31 2M + E39-F3R+E39-RP37 1  
E32-C31 2M + E39-F3R+E39-RSP1 1  
150 to 1,500  
10 to 250  
150  
Retrore-  
flective  
models  
250  
600  
200  
300  
100  
150  
50  
75  
Film detection 2  
225  
1. When using a highly reflective object, light reflected from the object may affect the sensor.  
2. The effect may be small due to the film. Also, stable detection may not be possible when there is a sensing object directly in front of the Lens  
Unit. Be sure to check operation in advance.  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
FPD / Semiconductor / Solar battery industry  
Sensing distance (unit: mm)  
Sensing  
method  
Operating  
temperature  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
Application  
Model  
E32-L16-N 2M ✽  
E32-L16-N 2M ✽  
E32-A08 2M ✽  
E32-A08H2 3M ✽  
E32-A09 2M  
Tough mode  
mode  
speed mode  
Glass detection  
0 to 15  
0 to 15  
0 to 12  
70°C  
0 to 12  
Glass substrate  
alignment  
10 to 20  
10 to 20  
15 to 38  
15 to 38  
20 to 30  
300°C  
70°C  
Reflective  
models  
Glass substrate  
mapping  
150°C  
300°C  
60°C  
E32-A09H 2M  
E32-A09H2 2M  
E32-L11FP 5M  
E32-L12FS 5M  
E32-L11FS 5M  
E32-A03 2M  
8 to 20 mm from end of lens (recommended: 11 mm)  
8 to 20 mm from end of lens (recommended: 11 mm)  
8 to 20 mm from end of lens (recommended: 11 mm)  
WET process  
70°C  
85°C  
1,610  
1,610  
640  
1,150  
1,150  
460  
890  
890  
340  
340  
600  
600  
225  
225  
250  
250  
100  
100  
Through-  
beam  
models  
E32-A03-1 2M  
E32-A04 2M  
Wafer mapping  
70°C  
E32-A04-1 2M  
640  
460  
If operation is affected by the background, perform power tuning to reduce the amount of light that is received.  
Fiber Unit  
Amplifier Unit  
E3X-DA@R-S (@: 21/51/7/9)  
Liquid-level detection model  
Sensing distance (unit: mm)  
Sensing  
method  
Sensing  
direction  
High-resolution  
mode  
Standard  
mode  
High-speed Super-high-  
mode speed mode  
Pipe diameter  
No limit  
Model  
E32-D36T 5M ✽  
Tough mode  
Applicable pipe: Transparent (no restriction on diameter)  
Mounted to pipe  
Wet  
Reflective  
models  
Applicable pipe: Transparent pipe with diameter of 8 to 10 mm,  
recommended pipe wall thickness: 1 mm  
φ8 to 10mm  
---  
E32-L25T 2M  
E32-D82F1 4M ✽  
Wet model  
If a high level of light is received, perform power tuning to reduce the amount of light that is received.  
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).  
12  
E3X-DA-S  
I/O Circuit Diagrams  
NPN Output  
Operation  
Operation  
selector  
Model  
mode  
Timing charts  
Output circuit  
ch1/  
ch2  
Incident light  
No incident light  
E3X-DA21-S  
Display  
Operation indicator  
(orange) ch2  
Operation indicator  
(orange)  
ON  
OFF  
ON  
OFF  
Operate  
Reset  
Brown  
Black  
LIGHT ON  
(L-ON)  
Opera-  
tion  
indicator  
(orange)  
ch1  
Light-ON  
Output transistor  
Load  
Load  
Photo-  
Control output  
Orange  
Load  
(e.g., relay)  
electric  
Sensor  
main  
ch1  
12 to  
24 VDC  
E3X-DA21-S  
E3X-DA21R-S  
E3X-DA21F-S  
(Between brown and black (orange) leads)  
Control output  
Pink  
circuit  
ch2 1  
ch1/  
ch2  
Incident light  
No incident light  
External  
Operation indicator  
(orange)  
ON  
OFF  
ON  
input 2  
Blue  
DARK ON  
(D-ON)  
Dark-ON  
Light-ON  
Dark-ON  
Output transistor  
OFF  
1. For the E3X-DA21R-S, this is the APC alarm output.  
This output does not exist on the E3X-DA21F-S.  
2. This input does not exist the E3X-DA21F-S.  
Operate  
Reset  
Load  
(e.g., relay)  
(Between brown and black (orange) leads)  
ch1/  
ch2  
Incident light  
No incident light  
E3X-DA7-S  
Operation indicator  
Operation indicator  
(orange)  
ON  
OFF  
ON  
Display  
(orange) ch2  
Brown  
LIGHT ON  
(L-ON)  
Opera-  
tion  
indicator  
(orange)  
ch1  
Output transistor  
Load  
Black  
OFF  
Operate  
Reset  
Photo-  
Control output Load  
Load  
(e.g., relay)  
electric  
Sensor  
main  
ch1  
Orange  
12 to  
24 VDC  
E3X-DA7-S  
E3X-DA7R-S  
E3X-DA7F-S  
(Between brown and black (orange) leads)  
Control output  
ch2  
circuit  
ch1/  
ch2  
Incident light  
No incident light  
Blue  
Operation indicator  
(orange)  
ON  
OFF  
ON  
DARK ON  
(D-ON)  
Output transistor  
OFF  
Operate  
Reset  
(Between brown and black (orange) leads)  
For the E3X-DA7R-S, this is the APC alarm output.  
This output does not exist on the E3X-DA7F-S.  
Load  
(e.g., relay)  
PNP Output  
Model  
Operation  
mode  
Operation  
selector  
Timing charts  
Output circuit  
ch1/  
ch2  
Incident light  
No incident light  
E3X-DA51-S  
Operation indicator (orange) ch2  
Display  
Operation indicator  
(orange)  
ON  
OFF  
ON  
Brown  
LIGHT ON  
(L-ON)  
Opera-  
Light-ON  
Dark-ON  
Light-ON  
Dark-ON  
External  
Output transistor  
tion  
input 2  
Pink  
OFF  
indicator  
Control output  
ch1  
Operate  
Reset  
(orange)  
ch1  
Load  
(e.g., relay)  
Photo-  
electric  
Sensor  
main  
Black  
12 to  
24 VDC  
E3X-DA51-S  
E3X-DA51R-S  
E3X-DA51F-S  
(Between blue and black (orange) leads)  
Control output  
Orange  
ch2 1  
Load  
circuit  
ch1/  
ch2  
Incident light  
No incident light  
Load  
Blue  
Operation indicator  
(orange)  
ON  
OFF  
ON  
DARK ON  
(D-ON)  
Output transistor  
OFF  
1. For the E3X-DA51R-S, this is the APC alarm output.  
This output does not exist on the E3X-DA51F-S.  
2. This input does not exist the E3X-DA51F-S.  
Operate  
Reset  
Load  
(e.g., relay)  
(Between blue and black (orange) leads)  
ch1/  
ch2  
Incident light  
No incident light  
E3X-DA9-S  
Operation indicator (orange) ch2  
Operation indicator  
(orange)  
Display  
ON  
OFF  
ON  
OFF  
Operate  
Reset  
Brown  
LIGHT ON  
(L-ON)  
Opera-  
tion  
indicator  
(orange)  
ch1  
Output transistor  
Photo-  
electric  
Sensor  
main  
Control output  
Black  
Load  
(e.g., relay)  
ch1  
12 to  
24 VDC  
E3X-DA9-S  
E3X-DA9R-S  
E3X-DA9F-S  
(Between blue and black (orange) leads)  
Control output  
Orange  
ch2  
circuit  
Load  
ch1/  
ch2  
Incident light  
No incident light  
Load  
Blue  
Operation indicator  
(orange)  
ON  
OFF  
ON  
DARK ON  
(D-ON)  
Output transistor  
OFF  
For the E3X-DA9R-S, this is the APC alarm output.  
This output does not exist on the E3X-DA9F-S.  
Operate  
Reset  
(Between blue and black (orange) leads)  
Load  
(e.g., relay)  
Note: 1. Operation with area settings is as follows:  
LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2.  
DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2.  
2. Timing Charts for Timer Settings (T: Set Time)  
ON delay  
OFF delay  
One-shot  
ON delay and OFF delay  
Incident light  
Incident light  
Incident light  
Incident light  
No incident light  
No incident light  
No incident light  
No incident light  
T2  
T1  
T1  
T2  
T
T
T
T1: ON-delay set time  
T2: OFF-delay set time  
T1 and T2 can be set separately.  
ON  
OFF  
ON  
ON  
ON  
ON  
L-ON  
D-ON  
L-ON  
L-ON  
L-ON  
OFF  
OFF  
OFF  
T
T
T
ON  
ON  
ON  
D-ON  
D-ON  
D-ON  
OFF  
OFF  
OFF  
OFF  
13  
E3X-DA-S  
Nomenclature  
Amplifier Units  
E3X-DA@-S (@: 21/51/7/9)  
Main Display (Red)  
Incident level, function, etc.  
Sub-Display (Green)  
Threshold, function settings,  
etc.  
Operation Keys  
Function setting  
UP  
Lock lever  
Locks the fiber.  
operations  
DOWN  
MODE  
Channel Selector  
Operation Indicator  
(ch2) (orange)  
Operation Indicator  
(ch1) (orange)  
ON when output is ON.  
Note: Nomenclature and operating procedures for the E3X-  
DA@R-S and E3X-DA@F-S (@: 21/51/7/9) are given on  
pages 19 and 20.  
Use to select the channel to display and set.  
ON when output is ON.  
Mode Selector  
Use to select SET or RUN Mode.  
OFF when output is OFF. OFF when output is OFF.  
Operating Procedure  
1
Setting the Operation Mode  
To restore the default  
DOWN  
MODE  
Press  
both  
for 3 s.  
power setting:  
The operation mode is set in SET Mode.  
Refer to 5. Setting Functions on page 16.  
Press the DOWN Key  
right after pressing  
the MODE Key.  
PTUN  
OFF  
Set the Channel Selector Switch to the desired channel  
before making any adjustments or settings.  
"OFF" will flash twice.  
2
Adjusting the Power (RUN Mode)  
Incident level  
Threshold  
The current incident light level can be adjusted near the  
power tuning target value (default: 2,000).  
This restores the default  
setting.  
Confirm that the MODE Key setting is PTUN (power tuning). The  
Setting Errors  
default setting is PTUN.  
Refer to 5. Setting Functions on page 16.  
An error has occurred if one of the following displays appears after  
the progress bar is displayed.  
If power tuning is executed while SHS is selected for the detection  
function, the minimum power will be set.  
Display  
Error  
Action  
Flashes twice  
Over Error  
The power will not  
be tuned. The power  
can be increased up  
to approximately 5  
times the incident  
light value.  
The incident light  
level is too low  
for the power  
tuning target  
value.  
Incident level  
Threshold (default)  
Set the SET/RUN Mode  
Selector Switch to RUN.  
PTUN  
PTUN  
OVER  
RUN  
(Factory-set to RUN)  
Bottom Error  
The power will be  
turned to the  
minimum level. The  
power can be  
decreased down to  
approximately  
Flashes twice  
The incident light  
level is too high  
for the power  
tuning target  
value.  
MODE  
3 s  
BOTM  
1/20th the incident  
light value.  
PTUN  
Progress bar  
Release the key after  
the progress bar is  
displayed.  
3
Setting Thresholds Manually (RUN Mode)  
Display changes after  
specific time.  
A threshold can be set manually. A threshold can also  
be adjusted manually after teaching to fine-tune it.  
Power tuning  
target value  
Light level  
Threshold (default)  
Set the Mode Selector  
Switch to RUN.  
Incident level  
Threshold  
RUN  
This completes the  
adjustment.  
(Factory-set to RUN)  
UP  
DOWN  
Increases threshold.  
Decreases threshold.  
Even if the display method is changed, the threshold will appear  
on the sub-display when the key is pressed.  
14  
E3X-DA-S  
4
Teaching the Threshold (SET Mode)  
There are five methods that can be used for teaching, as described  
below. Use the method most suitable for the application.  
Two-point teaching, positioning teaching, and automatic teaching  
can be performed in RUN Mode.  
For operating procedures, refer to the Instruction Manual provided  
with the product.  
4-3. Teaching a Reflective Fiber Unit without a Workpiece  
You can set the threshold to above the incident light level without  
a workpiece by the percentage set for the teaching level.  
Refer to 5. Setting Functions on page 16.  
An error has occurred if OVER or LO is displayed on the  
sub-display. If that occurs, repeat the operation from the beginning.  
Incident level  
Threshold  
Set the SET/RUN Mode  
Selector Switch to SET.  
SET  
4-1. Setting the Threshold at Maximum Sensitivity  
The threshold can be set to the maximum sensitivity.  
This is useful when the longest detection distance is  
required.  
UP  
DOWN  
Press  
either  
for 1 s.  
With no workpiece:  
Incident level  
Threshold  
Set the SET/RUN Mode  
TECH  
----  
Selector Switch to SET.  
SET  
"----" will be displayed.  
UP  
DOWN  
Press  
either  
UP  
DOWN  
With no workpiece:  
Press  
either  
for 3 s.  
for 3 s.  
FULL  
Threshold  
The threshold that  
was set will flash twice.  
RFCT  
Threshold  
The threshold that  
was set will flash twice.  
Set the SET/RUN Mode  
Selector Switch to RUN  
to complete the setting  
procedure.  
Incident level  
Threshold  
Set the SET/RUN Mode  
Selector Switch to RUN  
to complete the setting  
procedure.  
Incident level  
Threshold  
4-4. Two-point Teaching  
4-5. Positioning Teaching  
4-2. Teaching a Through-beam Fiber Unit without a Workpiece  
You can set the threshold to below the incident light level  
without a workpiece by the percentage set for the teaching  
level.  
Two points in the following figures are detected, and  
the intermediate point of the light levels for the  
two points is set as the threshold.  
Refer to 5. Setting Functions on page 16.  
Incident level  
Threshold  
Incident level  
Threshold  
Set the SET/RUN Mode  
Set the SET/RUN Mode  
Selector Switch to SET.  
Selector Switch to SET.  
SET  
SET  
UP  
DOWN  
Press  
either  
for 1 s.  
With a workpiece:  
For positioning  
teaching, place the  
workpiece where  
you want to  
UP  
DOWN  
Press  
either  
With no workpiece:  
for 1 s.  
TECH  
----  
Workpiece  
position it.  
TECH  
----  
"----" will be displayed.  
"----" will be displayed.  
RUN  
To RUN  
With no workpiece:  
For positioning  
teaching, place the  
workpiece where  
you want to  
UP  
DOWN  
Press  
either  
for 1 s.  
THRU  
Threshold  
Threshold  
The threshold that  
was set will flash twice.  
position it.  
2PNT  
Threshold  
Threshold  
The threshold that  
was set will flash twice.  
Incident level  
This completes the  
setting procedure.  
Set the SET/RUN Mode  
Selector Switch to RUN  
to complete the setting  
procedure.  
Incident level  
15  
E3X-DA-S  
5
Setting Functions (SET Mode)  
The function transition boxes show the default settings.  
More functions may be displayed depending on the detailed settings.  
Refer to 4. Teaching the  
Threshold on page 15.  
Moving between Functions  
Teaching  
0. Operation mode  
(To set the operation mode)  
1. Detection  
(To change response speed and  
3. Teaching level  
(To change the teaching level)  
2. Timer  
(To use the timer setting)  
Set the SET/RUN Mode  
Selector Switch to SET.  
SET  
detection precision)  
11. External input memory  
(Refer to the Instruction Manual  
provided with the sensor.)  
4. ATC setting  
(To change the ATC setting)  
MODE  
10. External input  
9. Output setting  
8. ECO Mode  
7. Display orientation  
6. Display switch  
5. MODE Key  
(To change functions controlled  
(To change outputs for  
(To set the ECO Mode)  
(To change the display method)  
(To change the function of the  
(To reverse the orientation of  
MODE Key during operation)  
the display.)  
using the external input)  
channel 2)  
Set the SET/RUN Mode  
Selector Switch to RUN.  
RUN  
When the  
settings have  
been completed  
Functions  
UP  
DOWN  
Use the UP and DOWN Keys to change the settings.  
Function ✽  
Setting (display)  
Description  
Refer to 1. Setting the Operation Mode on page 14.  
Light ON:  
, Dark ON:  
0. Operation mode  
1. Detection ✽  
Super-high-speed:  
High-resolution:  
, High-speed:  
, Tough: , Differential operation:  
, Standard:  
,
Used to change the response speed or detection precision.  
Used to set the edge to be detected.  
Differential edge  
(differential operation  
selected)  
Single edge:  
, Double edge:  
Single edge···250 µs: , 500 µs: , 1 ms: , 10 ms: , 100 ms:  
Double edge···500 µs: , 1 ms: , 2 ms: , 20 ms: , 200 ms:  
,
Differential time  
Used to set the differential response time.  
Timer disabled:  
ON-delay timer:  
, OFF-delay timer:  
, One-shot timer:  
,
2. Timer  
Used to enable or disable timers.  
ON-delay + OFF-delay timer:  
1 to 20 ms: 1-ms increments, 20 to 200 ms: 10-ms increments,  
200 ms to 1 s: 100-ms increments, 1 to 5 s: 1-s increments  
Time  
(timer enabled)  
Used to change timer settings when timers are enabled.  
The timer can be set from 1 to 5,000 ms.  
Used to change the threshold setting when teaching a  
Through-beam Fiber Unit without a workpiece or teaching  
a Reflective Fiber Unit without a workpiece.  
3. Teaching level  
Setting range:  
to  
4. ATC setting  
ATC enabled:  
No setting:  
, ATC disabled:  
Used to enable or disable the ATC function.  
Setting at Power-ON  
(ATC ON)  
, ATC start processing:  
,
Used to set the processing to be performed when the  
power is turned ON.  
Power tuning and ATC start processing:  
Executes power tuning:  
Executes a zero reset:  
Automatic teaching:  
,
Used to change the function of the MODE Key during RUN  
operation.  
5. MODE Key ✽  
, Two-point teaching:  
, ATC start:  
,
Used to set target values during power tuning.  
Refer to 2. Adjusting the Power on page 14.  
Power tuning target value  
(performing power tuning)  
Setting range: 100 to 3,900 (increments of 100)  
Maximum power :  
The detection settings and MODE Key settings are the same for channel 1 and channel 2.  
Other functions can be set separately for each channel.  
16  
E3X-DA-S  
Function  
Setting (display)  
Description  
Used to display the incident light level and the  
threshold.  
Incident level Threshold  
% incident level Threshold  
Used to display the incident light level as a percentage of  
the threshold and the threshold.  
Used to display the peak and bottom levels of incident  
light within a set time. (Updated every 2 s.)  
Fixed interval  
PEAK  
L-PE  
BOTM  
D-BT  
Use to display the incident light peak level and no incident  
light bottom level. (Refreshed when output turns ON or OFF.)  
6. Display switch  
Analog bar display. The current detection status is  
displayed as an analog bar. The bar will lengthen  
from the right as ON status is reached.  
(ON: Red, OFF: Green)  
Detection status  
Used to display the current incident light level and the peak  
incident light level. Display changes at a fixed interval.  
Fixed interval  
Current incident  
level  
PEAK  
Current incident Peak incident  
level level  
Used to display the incident light level and the channel  
(unit number).  
Incident level Channel (unit number)  
7. Display orientation  
Normal display:  
, Up/down reversed display:  
Used to reverse the orientation of the display.  
Used to enable or disable the ECO mode.  
8. ECO Mode  
Lit degital display:  
OFF:  
, Dimmed degital display:  
,
Used to change the output details for channel 2.  
This setting will be disabled if the detection function is set  
to DIFF (i.e., differential operation) and the output will be  
used for an alarm output.  
Each channel:  
Output when the incident light level is between two thresholds:  
Self-diagnosis output:  
,
9. Output setting  
10. External input  
,
Through-beam, no-workpiece teaching:  
Reflective, no-workpiece teaching:  
Two-point teaching:  
Power tuning:  
,
Used to change the functions to be controlled using the  
external input.  
(Refer to the Instruction Manual provided with the sensor.)  
,
, Automatic teaching:  
, Zero reset:  
,
,
Light OFF:  
, ATC start:  
Write results to EEPROM:  
,
11. External input  
Used to set writing the results.  
Do not write results to EEPROM:  
memory  
(Refer to Instruction Manual provided with the product.)  
17  
E3X-DA-S  
6
Convenient Functions  
6-1. Setting the Digital Display to Zero (Zero Reset)  
6-3. Resetting Settings (Initial Reset or User Reset)  
The incident light level on the main display can be set to 0.  
The incident light level and the threshold will both be  
shifted. This is useful when you want to set the reference  
display to zero.  
All settings can be returned to the factory defaults or to  
user-saved settings.  
Set the SET/RUN Mode  
UP  
DOWN  
Press  
both  
for 5 s.  
Selector Switch to SET.  
SET  
Change the function to 0RST (zero reset) with the MODE Key.  
The default setting is PTUN.  
Refer to 5. Setting Functions on page 16.  
RST  
INIT  
RST  
USER  
Set the SET/RUN Mode  
MODE  
UP  
DOWN  
Selector Switch to RUN.  
3 s  
RUN  
MODE  
MODE  
Factory setting  
USER  
YES?  
USER  
NO?  
To return to original value for incident light level:  
Set the SET/RUN Mode  
1  
DOWN  
MODE  
Press  
Selector Switch to RUN.  
both  
RUN  
UP  
DOWN  
for 3 s.  
MODE  
MODE  
Factory setting  
Perform user reset.  
Operation canceled.  
6-2. Locking the Keys (Key Lock)  
(The steps within the dotted lines can be used if settings have  
been saved by the user.)  
All key operations can be disabled.  
Set the SET/RUN Mode  
2  
UP  
MODE  
Press  
both  
INIT  
NO?  
INIT  
YES?  
Selector Switch to RUN.  
for 3 s.  
RUN  
Factory setting  
LOC  
ON  
UP  
DOWN  
MODE  
MODE  
“LOC ONwill flash twice  
and key operations will be  
disabled.  
Operation canceled.  
Settings initialized.  
To release the lock:  
Saving User Settings  
The current settings can be saved.  
2  
Set the SET/RUN Mode  
UP  
MODE  
Press  
both  
Selector Switch to RUN.  
RUN  
for 3 s.  
Set the SET/RUN Mode  
UP  
MODE  
Press  
both  
Factory setting  
Selector Switch to SET.  
for 5 s.  
SET  
LOC  
“LOC OFF” will flash twice  
and key operations will be  
enabled.  
OFF  
SAVE  
YES?  
SAVE  
NO?  
If a key is pressed while key operations are locked, “LOC ONwill  
flash twice on the display to  
UP  
DOWN  
MODE  
MODE  
indicate that key operations have  
been disabled.  
The current settings are saved.  
Operation canceled.  
1. Press the DOWN Key right after pressing the MODE Key.  
2. Press the UP Key right after pressing the MODE Key.  
18  
E3X-DA-S  
Nomenclature  
Amplifier Units  
E3X-DA@R-S (@: 21/51/7/9)  
Main Display (Red)  
Incident level, function, etc.  
Sub-Display (Green)  
Threshold, function settings, etc.  
Operation Keys  
UP  
Lock lever  
Locks the fiber.  
Function setting  
DOWN  
MODE  
operations  
Easy key lock Selector  
Select to lock or unlock settings.  
Operation Indicator APC alarm output  
(orange)  
indicator (orange)  
ON when output is ON.  
OFF when output is OFF.  
Mode Selector  
Use to select SET or RUN Mode.  
ON when output is ON.  
OFF when output is OFF.  
Operating Procedure  
Basic operating procedures are as given on pages 14 to 18.  
For details, refer to the Instruction Manual provided with the product.  
This section shows functions specific to the E3X-DA@R-S.  
Margin  
Margin  
APC  
APC  
Initial status  
1
Locking the Keys (Easy Key Lock)  
Before shipment, all key operation except for the MODE  
Keys can be disabled.  
APC margin  
Set the Easy Key Lock  
Set the SET/RUN Mode  
displayed in  
Selector Switch to Locked .  
Selector Switch to RUN.  
decrements of 10%  
Locked  
RUN  
(Factory-set to RUN)  
Note: Do not switch the lock while in SET Mode. Doing so will disable  
changing settings. If the lock is switched to in SET Mode, return to  
the unlock state, and then make the setting again.  
Margin  
APC  
Unlocking  
APC margin of less  
than 10%  
Set the Easy Key Lock  
The display switches  
every second.  
Set the SET/RUN Mode  
Selector Switch to Unlocked .  
Selector Switch to RUN.  
Unlocked  
ALAT  
APC  
RUN  
(Factory-set to RUN)  
Margin  
APC  
2
Displaying the APC Margin  
Displaying the APC margin can be useful for planning  
maintenance. When the APC margin is 0%,  
APC alarm output will turn ON, and the APC alarm output  
indicator will light regardless of the operation of the APC  
margin display.  
APC margin is 0%.  
The display switches  
every 0.5 s.  
END  
APC  
Set the Easy Key Lock  
Set the SET/RUN Mode  
Selector Switch to Locked .  
Selector Switch to RUN.  
Locked  
RUN  
Press the MODE Key  
or press nothing for 10 s.  
MODE  
(Factory-set to RUN)  
MODE  
Press the MODE Key to  
display the following for 10 s.  
Incident level  
Threshold  
The display will return  
to the normal display.  
19  
E3X-DA-S  
Nomenclature  
Amplifier Units  
E3X-DA@F-S (@: 21/51/7/9)  
Main Display (Red)  
Incident level, function, etc.  
Sub-Display (Green)  
Threshold, function settings, etc.  
Operation Keys  
UP  
Lock lever  
Locks the fiber  
Function setting  
DOWN  
MODE  
operations  
Easy key lock Selector  
Select to lock or unlock settings.  
Operation Indicator  
(orange)  
ON when output is ON.  
OFF when output is OFF.  
Power tuning  
indicator (orange)  
ON when setting is ON.  
OFF when setting is OFF.  
Mode Selector  
Use to select SET or RUN Mode.  
Operating Procedure  
Basic operating procedures are as given on pages 14 to 18.  
For details, refer to the Instruction Manual provided with the product.  
This section shows functions specific to the E3X-DA@F-S.  
"A" is displayed when  
the output is ON or until  
approximately 10 s  
A
1
Locking the Keys (Easy Key Lock)  
has elapsed. (Key  
operations will not be  
accepted in the status.)  
Before shipment, all key operation except for the MODE  
Keys can be disabled.  
STAT  
"STAT" will be displayed  
and the slow-motion  
display will start.  
Set the Easy Key Lock  
Set the SET/RUN Mode  
Selector Switch to Locked .  
Selector Switch to RUN.  
Locked  
RUN  
(Factory-set to RUN)  
Incident level  
Incident level  
Incident level  
Threshold  
Threshold  
Threshold  
The incident level in  
intervals of 17 µs  
will be displayed  
for approximately 20 s  
every 160 ms  
(between 0.5 ms before  
ON to 1.5 ms after ON).  
Note: Do not switch the lock while in SET Mode. Doing so will disable  
changing settings. If the lock is switched to in SET Mode, return to  
the unlock state, and then make the setting again.  
Unlocking  
Set the Easy Key Lock  
Set the SET/RUN Mode  
Selector Switch to Unlocked .  
Selector Switch to RUN.  
Unlocked  
RUN  
(Factory-set to RUN)  
2
Displaying the Change of the incident level  
Press the MODE Key,  
or wait for the slow-motion  
display to end.  
MODE  
Changes of the incident level for high-speed workpiece  
detection can be displayed. This enables checking the  
margin level of light received and the workpiece ON time  
in slow motion.  
Output ON time Unit: µs  
Set the Easy Key Lock  
The output ON time will  
be displayed.  
Set the SET/RUN Mode  
Selector Switch to Locked .  
Selector Switch to RUN.  
Locked  
RUN  
(Factory-set to RUN)  
END  
END will be displayed.  
Incident level  
Threshold  
Turn OFF the output or  
convey the workpieces.  
Incident level  
Threshold  
MODE  
The display will return to  
Press the MODE key.  
the normal display.  
The following will be displayed  
if the ON time exceeds 1,500 µs.  
The following will be displayed  
if the change in the light amount is low. ✽  
Error  
Display  
This may also be displayed when detecting  
a workpiece with a small change in light amount  
or a slow workpiece of 1,500 µs or longer.  
OVER  
US  
NON  
DETC  
20  
E3X-DA-S  
Safety Precautions  
To ensure safe operation, be sure to read and follow the Instruction Manual provided with the sensor.  
WARNING  
Precautions for Correct Use  
This product is not designed or rated for ensuring  
safety of persons either directly or indirectly.  
Do not use it for such purposes.  
Do not use the product in atmospheres or environments that exceed  
product ratings.  
Amplifier Unit  
Designing  
Operation after Turning Power ON  
CAUTION  
The sensor is ready to detect within 200 ms after the power supply is  
turned ON. If the sensor and load are connected to separate power  
supplies, be sure to turn ON the sensor first.  
Time may be required for the incident level to stabilize after the power  
supply is turned ON.  
Do not use the sensor with voltage in excess of the  
rated voltage. Excess voltage may result in  
malfunction or fire.  
Never use the sensor with an AC power supply.  
Otherwise, explosion may result.  
Operation at Power OFF  
A pulse may be output when the power supply is turned OFF. Turn  
OFF the power supply to the load or the load line before turning OFF  
the power supply to the sensor.  
Mutual Interference Protection Function  
Precautions for Safe Use  
Mutual interference prevention is enabled if Amplifier Units are  
connected together. It is also enabled in the same way if E3X-DA-S-  
series Units and E3C-LDA-series Units are used together.  
The following precautions must be observed to ensure safe operation  
of the sensor.  
1. Do not use the sensor in an environment where explosive or  
flammable gas is present.  
2. Do not use the sensor in a location subject to splattering with  
water, streams, oils, or chemicals.  
3. Do not attempt to disassemble, repair, or modify the sensor.  
4. Do not apply voltages or currents that exceed the rated range to  
the sensor.  
Mounting  
Connecting and Disconnecting Connectors  
Mounting Connectors  
1. Insert the Master or Slave connector into the Amplifier Unit until it  
clicks into place.  
5. Do not use the sensor in an ambient atmosphere or environment  
that exceeds the ratings.  
6. Wire the power supply correctly, including the polarity.  
7. Connect the load correctly.  
8. Do not short-circuit the load at both ends.  
9. Do not use the sensor if the case is damaged.  
10.Dispose of the sensor as industrial waste.  
11.Do not use the sensor in locations subject to direct sunlight.  
Insert  
2. Attach the protective seals (provided as accessories) to the sides  
of master and slave connectors that are not connected.  
Seal  
Note: Attach the seals to the sides with grooves.  
Removing Connectors  
1. Slide the slave Amplifier Unit away from the other unit.  
2. After the Amplifier Unit has been separated, press down on the  
lever on the connector and remove it. (Do not attempt to remove a  
connector without first separating the Amplifier Unit from the other  
Units.)  
Press down  
Lever  
Remove  
21  
E3X-DA-S  
Adding and Removing Amplifier Units  
Adding Amplifier Units  
Fibers with E39-F9 Attachment  
1. Mount the Amplifier Units one at a time onto the DIN track.  
Fiber Unit  
9 mm  
13 mm  
Fibers That Cannot Be Free-Cut (with Sleeves)  
2. Slide the Amplifier Units together, line up the clips, and press the  
Amplifier Units together until they click into place.  
Click into place  
9 mm  
13 mm  
2. Disconnecting Fibers  
Remove the protective cover and raise the lock lever to pull out the  
fibers.  
Removing Amplifier Units  
Slide Amplifier Units away from each other, and remove from the DIN  
track one at a time. (Do not attempt to remove Amplifier Units from the  
DIN track without separating them first.)  
Note: 1. The specifications for ambient temperature will vary  
according to the number of Amplifier Units used together.  
For details, refer to Ambient temperature range on  
page 4.  
Protective cover  
Unlocked  
Locked  
2. Always turn OFF the power supply before joining or  
separating Amplifier Units.  
Mounting the End Plate (PFP-M)  
Use an End Plate if the Amplifier Unit might move due to vibration.  
Note: 1. To maintain the fiber properties, confirm that the lock is  
released before removing the fibers.  
2. Be sure to lock or unlock the lock lever within an ambient  
temperature range between 10°C and 40°C.  
Adjusting  
Mutual Interference Protection Function  
The values that appear on the digital display may fluctuate somewhat  
due to light from other sensors. If this occurs, you can stabilize  
detection by setting a threshold that is close to half way between the  
incident levels with and without a sensing object.  
End Plate  
Fiber Connection  
The E3X Amplifier Unit has a lock lever for easy connection of the  
Fiber Unit. Connect or disconnect the fibers using the following  
procedures:  
Output Short-circuits  
OVER/CUR will flash on the display if the output short-circuit  
protection function operates due to a load short-circuit in a control  
output. If this occurs, check the load connections.  
1. Connecting Fibers  
Open the protective cover, insert the fibers according to the fiber  
insertion marks on the side of the Amplifier Unit, and lower the lock  
lever.  
EEPROM Writing Error  
If the data is not written to the EEPROM correctly due to a power  
failure or static-electric noise, initialize the settings with the keys on  
the Amplifier Unit. ERR/EEP will flash on the display when a writing  
error has occurred.  
Optical Communications  
Protective cover  
Several Amplifier Units can be slid together and used in groups. Do  
not, however, slide the Amplifier Units or attempt to remove any of the  
Amplifier Units during operation.  
Lock lever  
Unlocked  
Locked  
Insertion position  
Others  
Protective Cover  
Always keep the protective cover in place when using the Amplifier  
Unit.  
Fiber insertion mark  
Fiber  
Mobile Console  
9 mm  
The E3X-MC11-SV2 Mobile Console does not currently support the  
new Tough Mode and ON-delay + OFF-delay timer. You also cannot  
use the E3X-MC-S.  
Note: Do not pull on the fiber, apply pressure on it, or otherwise  
subject it to excessive force when it is attached to the  
Amplifier Unit. (Use a force of 0.3 N·m max.)  
Communications Unit  
Use an E3X-DRT21-S Version 3 Communications Unit. This is not  
supported for the E3X-DA@R-S and E3X-DA@F-S (@: 21/51/7/9).  
22  
E3X-DA-S  
(Unit: mm)  
Dimensions  
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.  
Amplifier Units  
Pre-wired Models  
E3X-DA21-S  
E3X-DA51-S  
Digital Display Area  
1. The indicators are as follows:  
Indicator 1  
E3X-DA21-S  
E3X-DA51-S  
Operation indicator  
(2 ch)  
15.6  
35.25  
E3X-DA21R-S  
E3X-DA51R-S  
E3X-DA21F-S  
E3X-DA51F-S  
100  
E3X-DA21R-S  
E3X-DA51R-S  
APC alarm output  
indicator  
6.3  
E3X-DA21F-S  
E3X-DA51F-S  
Power tuning  
indicator  
Operation indicator (1ch)  
Main display  
Sub-display  
DIN track mounting  
4.3  
141.1  
180°  
101.45  
Vinyl-insulated round cable  
Standard length: 2 m 2  
322  
(9)  
4.5  
Multiple connection diagram  
12.5  
End Plate  
5.65  
3.4  
(sold separately)  
PFP-M  
L
Hole for optical communications  
Two, 2.4 dia.  
18.7  
(36.2)  
(21.3)  
700  
Center of DIN track  
DIN track  
(sold separately)  
PFP-@N  
10  
10  
The number of expansion  
L (mm)  
10  
20  
1
2
3
30  
4
40  
Fiber Attachment mounted (E39-F9)  
5
50  
6
7
60  
70  
100  
8
80  
9
90  
10  
100  
With Mounting Bracket Attached  
4.3  
141.1  
180°  
101.45  
Vinyl-insulated round cable  
Standard length: 2 m 2  
322  
(9)  
4.5  
12.5  
5.65  
3.4  
Two, 2.4 dia.  
Two, 3.2 dia.  
Holes  
Hole for optical communications  
4.3  
18.7  
16  
700  
10.3  
(9.4)  
Mounting Bracket (E39-L143)  
SUS304 stainless steel (sold separately)  
Mounting Holes  
3.4  
4.4  
2-M3  
16  
28.1  
16  
2. The cable specifications are as follows:  
Fiber Attachment mounted (E39-F9)  
E3X-DA21-S  
4 dia. cable / 5 conductors  
E3X-DA51-S  
E3X-DA21R-S  
E3X-DA51R-S  
(Conductor cross section: 0.2 mm2,  
Insulator diameter: 1.1 mm)  
4 dia. cable / 3 conductors  
E3X-DA21F-S  
E3X-DA51F-S  
(Conductor cross section: 0.2 mm2,  
Insulator diameter: 1.1 mm)  
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the  
Amplifier Units if they are mounted side by side.  
23  
E3X-DA-S  
Wire-saving connector Models  
E3X-DA7-S  
E3X-DA9-S  
Digital Display Area  
1. The indicators are as follows:  
Indicator 1  
E3X-DA7-S  
E3X-DA9-S  
Operation indicator  
(2 ch)  
15.6  
35.25  
E3X-DA7R-S  
E3X-DA7R-S  
E3X-DA9R-S  
APC alarm output  
indicator  
E3X-DA9R-S  
E3X-DA7F-S  
6.3  
Sub-display  
10  
E3X-DA7F-S  
E3X-DA9F-S  
Power tuning  
indicator  
Operation indicator (1ch)  
4.3  
Main display  
E3X-DA9F-S  
DIN track mounting  
141.1  
8.1  
180°  
101.45  
Dia. A 2  
32  
(9)  
4.5  
12.95  
5.65  
3.4  
Hole for optical communications  
Two, 2.4 dia.  
18.7  
Multiple connection diagram  
(36.2)  
(21.3)  
End Plate  
700  
(sold separately)  
PFP-M  
L
Center of DIN track  
DIN track  
(sold separately)  
PFP-@N  
10  
10  
The number of expansion  
L (mm)  
10  
Fiber Attachment mounted (E39-F9)  
1
2
20  
3
30  
4
40  
5
50  
6
60  
7
70  
10  
8
80  
9
10  
90  
100  
With Mounting Bracket Attached  
4.3  
141.1  
8.1  
180°  
101.45  
Dia. A 2  
32  
(9)  
4.5  
12.95  
5.65  
3.4  
Two, 3.2 dia.  
Holes  
18.7  
Hole for optical communications  
Two, 2.4 dia.  
4.3  
(9.4)  
16  
700  
10.3  
Mounting Bracket (E39-L143)  
SUS304 stainless steel (sold separately)  
Mounting Holes  
3.4  
4.4  
2-M3  
2. The cable diameters are as follows:  
E3X-CN21 (4 conductors)  
E3X-CN22 (2 conductors) 4.0 dia.  
E3X-CN11 (3 conductors)  
16  
28.1  
16  
Fiber Attachment mounted (E39-F9)  
E3X-CN12 (1 conductor) 2.6 dia.  
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier  
Units if they are mounted side by side.  
24  
E3X-DA-S  
Wire-saving connector  
Master connector  
E3X-CN21  
2,000+50  
0
Edge of amplifier  
(7)  
E3X-CN21: 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)  
Slave connector  
E3X-CN22  
2,000+50  
0
Edge of amplifier  
(7)  
E3X-CN22: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)  
Master connector  
E3X-CN11  
2,000+50  
0
Edge of amplifier  
(7)  
Cable 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)  
Slave connector  
E3X-CN12  
2,000+50  
0
Edge of amplifier  
(7)  
Cable 2.6-dia. vinyl-insulated round cable with 1 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)  
25  
E3X-DA-S  
Accessories (sold separately)  
Mounting Brackets  
E39-L143  
34.8  
22  
2.5  
3
(10.3)  
16  
Mounting Holes  
7.3  
5.3  
2-M3  
26.8  
7
Two, 3.2 dia.  
±0.1  
16  
3
16  
3
Four, R1.7  
10.3 10 max.  
7
3.4  
Material: Stainless steel (SUS304)  
1
3.4  
1
End Plate  
PFP-M  
50  
M4×8  
11.5  
panhead screw  
10  
M4 spring washer  
4.8  
6.2  
10  
1
1.3  
1.8  
35.5  
35.3  
1.8  
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).  
26  
READ AND UNDERSTAND THIS DOCUMENT  
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or  
comments.  
WARRANTY  
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if  
specified) from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,  
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT  
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR  
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR  
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,  
NEGLIGENCE, OR STRICT LIABILITY.  
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND  
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
SUITABILITY FOR USE  
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING  
SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH  
PURPOSES. Please refer to separate catalogs for OMRON's safety rated products.  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the  
customer’s application or use of the product.  
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply  
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end  
product, machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all  
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.  
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
• Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT  
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED  
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PERFORMANCE DATA  
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may  
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject  
to the OMRON Warranty and Limitations of Liability.  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix  
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.  
COPYRIGHT AND COPY PERMISSION  
This document shall not be copied for sales or promotions without permission.  
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or  
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in  
its entirety.  
OMRON Corporation  
Tokyo, JAPAN  
Industrial Automation Company  
Authorized Distributor:  
Contact: www.ia.omron.com  
Regional Headquarters  
OMRON EUROPE B.V.  
OMRON ELECTRONICS LLC  
One Commerce Drive Schaumburg,  
Sensor Business Unit  
IL 60173-5302 U.S.A.  
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787  
Carl-Benz-Str. 4, D-71154 Nufringen, Germany  
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199  
© OMRON Corporation 2010 All Rights Reserved.  
In the interest of product improvement,  
specifications are subject to change without notice.  
OMRON (CHINA) CO., LTD.  
Room 2211, Bank of China Tower,  
200 Yin Cheng Zhong Road,  
OMRON ASIA PACIFIC PTE. LTD.  
No. 438A Alexandra Road # 05-05/08 (Lobby 2),  
Alexandra Technopark,  
Printed in Japan  
(0510)  
PuDong New Area, Shanghai, 200120, China  
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200  
CSM_1_1_0510  
Cat. No. E396-E1-02  
Singapore 119967  
Tel: (65) 6835-3011/Fax: (65) 6835-2711  

相关型号:

E3X-DA21-S2M

Digital Fiber Sensors
OMRON

E3X-DA21F-S

Digital Fiber Sensors
OMRON

E3X-DA21F-S2M

Digital Fiber Sensors
OMRON

E3X-DA21R-S

Digital Fiber Sensors
OMRON

E3X-DA21R-S2M

Digital Fiber Sensors
OMRON

E3X-DA41

Analog Circuit
OMRON

E3X-DA41-N

The Ultimate Fiber Amplifier for Maximum Ease of Use and High Performance
OMRON

E3X-DA41-S

Super Dual Fiber Sensor
OMRON

E3X-DA41AN-S

Super Dual Fiber Sensor
OMRON

E3X-DA41AT-S

Evolution and Perfection The next-generation platform for a wide range of sensing
OMRON

E3X-DA41RM-S

Digital Fiber Sensors
OMRON

E3X-DA41SE-S

Evolution and Perfection The next-generation platform for a wide range of sensing
OMRON