NCP1399 Series
High Performance Current
Mode Resonant Controller
with Integrated High-
Voltage Drivers
www.onsemi.com
The NCP1399 is a high performance current mode controller for half
bridge resonant converters. This controller implements 600 V gate
drivers, simplifying layout and reducing external component count. The
built−in Brown−Out input function eases implementation of the
controller in all applications. In applications where a PFC front stage is
needed, the NCP1399 features a dedicated output to drive the PFC
controller. This feature together with dedicated skip mode technique
further improves light load efficiency of the whole application. The
NCP1399 provides a suite of protection features allowing safe operation
in any application. This includes: overload protection, over−current
protection to prevent hard switching cycles, brown−out detection, open
optocoupler detection, automatic dead−time adjust, overvoltage (OVP)
and overtemperature (OTP) protections.
16
1
SOIC−16 NB
(LESS PINS 2 AND 13)
D SUFFIX
CASE 751DU
MARKING DIAGRAM
16
NCP1399xy
AWLYWWG
Features
• High−Frequency Operation from 20 kHz up to 750 kHz
• Current Mode Control Scheme
1
NCP1399= Specific Device Code
• Automatic Dead−time with Maximum Dead−time Clamp
• Dedicated Startup Sequence for Fast Resonant Tank Stabilization
• Skip Mode Operation for Improved Light Load Efficiency
• Off−mode Operation for Extremely Low No−load Consumption
• Latched or Auto−Recovery Overload Protection
• Latched or Auto−Recovery Output Short Circuit Protection
• Latched Input for Severe Fault Conditions, e.g. OVP or OTP
• Out of Resonance Switching Protection
x
y
A
WL
Y
= A or B
= A, B, C, F, G H, I, J, K, L, M, N, P
= Assembly Location
= Wafer Lot
= Year
= Work Week
WW
G
= Pb−Free Package
PIN CONNECTIONS
• Open Feedback Loop Protection
1
HV
16 VBOOT
15 HB
• Precise Brown−Out Protection
• PFC Stage Operation Control According to Load Conditions
• Startup Current Source with Extremely Low Leakage Current
• Dynamic Self−Supply (DSS) Operation in Off−mode or Fault Modes
• Pin to Adjacent Pin / Open Pin Fail Safe
14
3
4
5
6
VBULK/PFCFB
SKIP/REM
LLCFB
MUPPER
12 MLOWER
11
LLCCS
GND
10 VCC
PFCMODE
• These are Pb−Free Devices
OVP/OTP
PON/OFF
7
8
Typical Applications
9
• Adapters and Offline Battery Chargers
• Flat Panel Display Power Converters
• Computing Power Supplies
(Top View)
ORDERING INFORMATION
See detailed ordering and shipping information on page 12 of
• Industrial and Medical Power Sources
this data sheet.
© Semiconductor Components Industries, LLC, 2016
1
Publication Order Number:
September, 2017 − Rev. 13
NCP1399/D
NCP1399 Series
Figure 1. Typical Application Example without PFC Stage − WLLC Design (Active OFF off−mode)
Figure 2. Typical Application Example with PFC Stage (Active OFF off−mode)
www.onsemi.com
2
NCP1399 Series
Figure 3. Typical Application Example with PFC Stage (Active ON off−mode)
PIN FUNCTION DESCRIPTION
Pin No.
Pin Name
Function
Pin Description
1
HV
High*voltage startup
current source input
Connects to rectified AC line or to bulk capacitor to perform functions of
Start*up Current Source and Dynamic Self*Supply
2
3
NC
Not connected
Increases the creepage distance
VBULK /
PFC FB
Bulk voltage monitoring input Receives divided bulk voltage to perform Brown−out protection.
4
SKIP/REM
Skip threshold adjust /
Off−mode control input
Sets the skip in threshold via a resistor connected to ground – version
NCP1399Ay. Activates off−mode (or Standby) when pulled−up by external
auxiliary voltage source / deactivates off−mode when pull down by external
off−mode control optocoupler – version NCP1399By.
5
6
7
LLC FB
LLC CS
LLC feedback input
Defines operating frequency based on given load conditions. Activates skip
mode operation under light load conditions. Activates off−mode operation for
NCP1399Ay version.
LLC current sense input
Senses divided resonant capacitor voltage to perform on−time modulation, out
of resonant switching protection, over−current protection and secondary side
short circuit protection.
OTP / OVP
Over−temperature and
over−voltage protection input
Implements over−temperature and over−voltage protection on single pin.
8
9
P ON/OFF
PFC turn−off FB level adjust Adjusts the FB pin to a level below which the PFC stage operation is disabled.
PFC MODE
PFC and external HV
switch control output
Provides supply voltage for PFC front stage controller and/or enables Vbulk
sensing network HV switch.
10
11
VCC
GND
Supplies the controller
Analog ground
The controller accepts up to 20 V on VCC pin
Common ground connection for adjust components, sensing networks and
DRV outputs.
12
13
14
15
16
MLOWER
NC
Low side driver output
Not connected
Drives the lower side MOSFET
Increases the creepage distance
Drives the higher side MOSFET
MUPPER
HB
High side driver output
Half*bridge connection
Bootstrap pin
Connects to the half*bridge output.
The floating VCC supply for the upper stage
VBOOT
www.onsemi.com
3
NCP1399 Series
Figure 4. Internal Circuit Architecture
MAXIMUM RATINGS
Rating
Symbol
Value
Unit
V
HV Startup Current Source HV Pin Voltage (Pin 1)
VBULK/PFC FB Pin Voltage (Pin3)
V
HV
−0.3 to 600
−0.3 to 5.5
−0.3 to 5.5
−0.3 to 10
−0.3 to 5.5
−5 to 5
V
V
BULK/PFC FB
SKIP/REM Pin Voltage (Pin 4) NCP1399Ay Revision Only
SKIP/REM Pin Voltage (Pin 4) NCP1399By Revision Only
LLC FB Pin Voltage (Pin 5)
V
V
SKIP/REM
V
V
SKIP/REM
V
FB
V
LLC CS Pin Voltage (Pin 6)
V
CS
V
PFC MODE Pin Output Voltage (Pin 9)
VCC Pin Voltage (Pin 10)
V
−0.3 to V + 0.3
V
PFC MODE
CC
V
CC
−0.3 to 20
V
Low Side Driver Output Voltage (Pin 12)
High Side Driver Output Voltage (Pin 14)
V
−0.3 to V + 0.3
V
DRV_MLOWER
CC
V
V
HB
– 0.3 to
V
DRV_MUPPER
V
BOOT
+ 0.3
High Side Offset Voltage (Pin 15)
V
V
V
−20 to
V
V
HB
Boot
+0.3
Boot
High Side Floating Supply Voltage (Pin 16)
T = −40°C to +125°C
J
V
BOOT
−0.3 to 620
−0.3 to 618
J
T = −55°C to −40°C
High Side Floating Supply Voltage (Pin 15 and 16)
Allowable Output Slew Rate on HB Pin (Pin 15)
OVP/OTP Pin Voltage (Pin 7)
V
−0.3 to 20.0
50
V
V/ns
V
Boot–VHB
dV/dt
max
V
−0.3 to 5.5
−0.3 to 5.5
−55 to 150
−55 to 150
130
OVP/OTP
P ON/OFF
P ON/OFF Pin Voltage (Pin 8)
V
V
Junction Temperature
T
J
°C
Storage Temperature
T
STG
°C
Thermal Resistance Junction−to−air
R
°C/W
kV
θ
JA
Human Body Model ESD Capability per JEDEC JESD22−A114F (except HV Pin – Pin 1)
Charged−Device Model ESD Capability per JEDEC JESD22−C101E
−
−
4.5
1
kV
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
1. This device contains latch−up protection and exceeds 100 mA per JEDEC Standard JESD78.
www.onsemi.com
4
NCP1399 Series
ELECTRICAL CHARACTERISTICS
(For typical values T = 25°C, for min/max values T = −40°C to +125°C, V = 12 V unless otherwise noted.)
J
J
CC
Symbol
HV Startup Current Source
Rating
Pin
Min
Typ
Max
Unit
V
Minimum voltage for current source operation
(V = V −0.5 V, I drops to 95 %)
1
1
−
−
−
−
60
60
V
V
HV_MIN1
CC
CC_ON
START2
V
Minimum voltage for current source operation
(V = V −0.5 V, I drops to 5 mA)
HV_MIN2
CC
CC_ON
START2
I
I
Current flowing out of V pin (V = 0 V)
1, 10
1, 10
1
0.2
6
0.5
9
0.8
13
10
8
mA
mA
mA
START1
CC
CC
Current flowing out of V pin (V = V −0.5 V)
CC_ON
START2
CC
CC
I
Off−state leakage current (V = 500 V, V = 15 V)
−
−
START_OFF
HV
CC
I
HV pin current when off−mode operation is active
(V = 400 V)
1
−
−
mA
HV_OFF−MODE
HV
Supply Section
V
Turn−on threshold level, V going up
10
10
15.3
11.5
15.8
12.0
16.3
12.3
V
V
CC_ON
CC_ON
CC
V
Turn−on threshold level, V going up
CC
(NCP1399AL, NCP1399AM)
V
Minimum operating voltage after turn−on
10
10
9.0
5.8
9.5
6.6
10
7.2
V
V
CC_OFF
V
V
CC
V
CC
level at which the internal logic gets reset
CC_RESET
CC_INHIBIT
V
level for I
to I
transition
10
0.40
100
10
0.80
125
27
1.25
150
40
V
START1
START2
V
Delay to generate DRVs pulses after V is reached
CC_ON
10
ms
mA
CC_ON_BLANK
CC_OFF−MODE
I
Controller supply current in off−mode,
10, 11
V
CC
= V
− 0.2 V (except NCP1399AG)
CC_ON
I
Controller supply current in skip−mode, V = 15 V
10, 11
mA
CC_SKIP−MODE
CC
(NCP1399AA, BA, AC, AH, AI, AK, AM, AN, AP)
(NCP1399AF, NCP1399AG, NCP1399AJ)
(NCP1399AL)
580
500
500
750
670
710
900
820
890
I
Controller supply current in latch−off mode,
10, 11
10, 11
10, 11
330
300
4.0
490
490
5.4
600
600
7.0
mA
mA
CC_LATCH
V
CC
= V
− 0.2 V (except NCP1399AI, AN, AP)
CC_ON
I
Controller supply current in auto−recovery mode,
= V − 0.2 V (except NCP1399AF)
CC_AUTOREC
V
CC
CC_ON
I
Controller supply current in normal operation,
= 100 kHz, C = 1 nF, V = 15 V
mA
CC_OPERATION
f
sw
load
CC
Bootstrap Section
V
Startup voltage on the floating section (Note 5)
Cutoff voltage on the floating section
16, 15
16, 15
16, 15
16, 15
8
9
10
9.0
V
V
BOOT_ON
V
7.2
30
8.2
75
BOOT_OFF
I
I
Upper driver consumption, no DRV pulses
130
2.00
mA
mA
BOOT1
BOOT2
Upper driver consumption, C
= 1 nF between Pins 13 &
1.30
1.65
load
15 f = 100 kHz, HB connected to GND
sw
HB Discharger
I
HB sink current capability V = 30 V
15
15
15
5
1
−
−
−
−
−
−
mA
mA
V
DISCHARGE1
DISCHARGE2
HB
I
HB sink current capability V = V
HB
HB_MIN
V
HB voltage @ I
changes from 2 to 0 mA
10
HB_MIN
DISCHARGE
Remote Input – NCP1399By
Remote pin voltage below which off−mode is deactivated
(V going down)
V
4
4
1.0
7.2
1.5
8.0
2.0
8.8
V
V
REM_ON
REM
V
Remote pin voltage above which off−mode is activated
(V going up)
REM_OFF
REM
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
2. The NCP1399Ay version has skip adjustable externally.
3. Guaranteed by design.
4. Minimal impedance on P ON/OFF pin is 1 kW
5. Minimal resistance connected in series with bootstrap diode is 3.3 W
www.onsemi.com
5
NCP1399 Series
ELECTRICAL CHARACTERISTICS
(For typical values T = 25°C, for min/max values T = −40°C to +125°C, V = 12 V unless otherwise noted.)
J
J
CC
Symbol
Remote Input – NCP1399By
Remote timer duration
Remote input leakage current (V
Rating
Pin
Min
Typ
Max
Unit
t
4
4
4
80
−
100
0.02
−
120
1.00
7
ms
mA
kW
REM_TIMER
I
= 10 V)
REM
REM_LEAK
R
Internal remote pull down switch resistance (V
= 8 V)
REM
3
SW_REM
Remote Control – NCP1399Ay (i.e. Off−mode is Sensed via FB Pin, except NCP1399AG)
V
FB pin voltage above which off−mode is deactivated
(V going up)
FB
5
5
5
1.5
0.36
1.0
2.0
0.40
2.3
2.5
0.44
4.0
V
V
FB_REM_ON
V
FB pin voltage below which off−mode is activated
(V going down)
FB
FB_REM_OFF
I
Pull−up FB pin bias current during off−mode
mA
FB_REM_BIAS
Driver Outputs
t
Output voltage rise−time @
C = 1 nF, 10−90% of output signal
L
12, 14
12, 14
20
5
45
30
80
50
ns
ns
r
t
Output voltage fall−time @
f
C = 1 nF, 10−90% of output signal
L
R
Source resistance
12, 14
12, 14
12, 14
4
1
−
16
5
32
11
−
W
W
A
OH
R
Sink resistance
OL
DRVSOURCE
I
Output high short circuit pulsed current
0.5
V
DRV
= 0 V, PW ≤ 10 ms
I
Output high short circuit pulsed current
= VCC, PW ≤ 10 ms
12, 14
−
−
1
−
−
5
A
DRVSINK
V
DRV
I
Leakage current on high voltage pins to GND
14, 15, 16
mA
HV_LEAK
Dead−time Generation
t
Maximum Dead−time value if no dV/dt falling/rising edge is
received
12, 14
720
−
800
8
880
−
ns
−
DEAD_TIME_MAX
N
Number of DT_MAX events to enters IC into fault
(NCP1399AA, NCP1399BA, NCP1399AH, NCP1399AK,
NCP1399AL)
12, 14, 16
DT_MAX
Number of DT_MAX events to enters IC into fault
(NCP1399AC, NCP1399AF, NCP1399AG, NCP1399AI,
NCP1399AJ, NCP1399AM, NCP1399AN, NCP1399AP)
12, 14, 16
−
16
−
−
dV/dt Detector
P
Positive slew rate on V
dead−time end is generated
pin above which automatic
16
16
−
−
210
210
−
−
V/ms
V/ms
dV/dt_th
BOOT
N
Negative slew rate on V
pin above which automatic
dV/dt_th
BOOT
dead−time end is generated
PFC MODE Output and P ON/OFF Adjust
V
V
PFC MODE output voltage when V < V
P ON/OFF
(sink 1 mA current from PFC MODE output)
9
9
5.75
6.00
−
6.25
−
V
V
PFC_M_BO
PFC_M_ON
PFC_M_LIM
FB
PFC MODE output voltage when V > V
V
0.4
−
FB
P ON/OFF
CC
(sink 10 mA current from PFC MODE output)
I
PFC MODE output current limit (V < 2 V)
9
0.7
9.4
1.2
−
1.85
10.9
mA
s
PFC MODE
t
Delay to transition PFC MODE from V
to
5, 8, 9
P ON/OFF_TIMER
PFC_M_ON
after V drops below V
FB P ON/OFF
V
PFC_M_BO
I
Pull−up current source (Note 4)
8
18
20
22
mA
P ON/OFF
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
2. The NCP1399Ay version has skip adjustable externally.
3. Guaranteed by design.
4. Minimal impedance on P ON/OFF pin is 1 kW
5. Minimal resistance connected in series with bootstrap diode is 3.3 W
www.onsemi.com
6
NCP1399 Series
ELECTRICAL CHARACTERISTICS
(For typical values T = 25°C, for min/max values T = −40°C to +125°C, V = 12 V unless otherwise noted.)
J
J
CC
Symbol
PFC MODE Output and P ON/OFF Adjust
Rating
Pin
Min
Typ
Max
Unit
P ON/OFF
P ON/OFF comparator hysteresis – percentage level of P
ON/OFF pin voltage
5, 8, 9
80
100
120
%
HYST
OVP/OTP
V
V
OVP threshold voltage (V
OTP threshold voltage (V
going up)
7
7
7
2.35
0.76
90
2.50
0.80
95
2.65
0.84
100
V
V
OVP
OTP
OTP
OVP/OTP
going down)
OVP/OTP
I
OTP/OVP pin source current for external NTC –
during normal operation
mA
I
OTP/OVP pin source current for external NTC –
during startup
7
180
190
200
mA
OTP_BOOST
t
Internal filter for OVP comparator
Internal filter for OTP comparator
7
7
7
32
200
7.3
37
330
8.0
44
500
8.7
ms
ms
OVP_FILTER
t
OTP_FILTER
t
Blanking time for OTP input during startup (NCP1399AA,
NCP1399BA, NCP1399AK)
ms
BLANK_OTP
Blanking time for OTP input during startup (NCP1399AC,
NCP1399AF, NCP1399AG, NCP1399AH, NCP1399AI,
NCP1399AJ, NCP1399AL, NCP1399AM, NCP1399AN,
NCP1399AP)
7
14
16
18
ms
V
OVP/OTP pin clamping voltage @ I
OVP/OTP pin clamping voltage @ I
= 0 mA
= 1 mA
7
7
1.0
1.8
1.2
2.4
1.4
3.0
V
V
CLAMP_OVP/OTP_1
OVP/OTP
OVP/OTP
V
CLAMP_ OVP/OTP_2
Start−up Sequence Parameters
t
Maximum on−time clamp (NCP1399AA, NCP1399BA,
NCP1399AK, NCP1399AL)
12, 14
12, 14
7.3
7.7
8.4
ms
ms
TON_MAX
Maximum on−time clamp (NCP1399AC, NCP1399AG,
NCP1399AI, NCP1399AM, NCP1399AN, NCP1399AP)
10.6
11.2
12.1
Maximum on−time clamp (NCP1399AF, NCP1399AJ)
Maximum on−time clamp (NCP1399AH)
12, 14
12, 14
12
15.2
8.8
16.3
9.5
17.8
10.5
5.4
ms
ms
ms
t
t
Initial Mlower DRV on−time duration (NCP1399AA,
NCP1399BA, NCP1399AC, NCP1399AG, NCP1399AH,
NCP1399AI, NCP1399AK, NCP1399AL, NCP1399AM,
NCP1399AN, NCP1399AP)
4.7
4.9
1st_MLOWER_TON
Initial Mlower DRV on−time duration (NCP1399AF,
NCP1399AJ)
12
9.3
10
11
ms
1st_MLOWER_TON
t
Initial Mupper DRV on−time duration (NCP1399AM)
14
14
0.44
0.72
0.50
0.79
0.57
0.88
ms
ms
1st_MUPPER_TON
t
Initial Mupper DRV on−time duration (NCP1399AA,
NCP1399BA, NCP1399AC, NCP1399AG, NCP1399AH,
NCP1399AI, NCP1399AK, NCP1399AL, NCP1399AN,
NCP1399AP)
1st_MUPPER_TON
t
Initial Mupper DRV on−time duration (NCP1399AF, NCP1399AJ)
14
0.99
17
1.10
20
1.21
22
ms
1st_MUPPER_TON
t
On−time period increment during soft−start (NCP1399AA,
NCP1399BA, NCP1399AC, NCP1399AG, NCP1399AH,
NCP1399AI, NCP1399AK, NCP1399AL, NCP1399AM,
NCP1399AN, NCP1399AP)
12, 14
ns
SS_INCREMENT
t
On−time period increment during soft−start (NCP1399AF,
NCP1399AJ)
12, 14
75
80
88
ns
SS_INCREMENT
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
2. The NCP1399Ay version has skip adjustable externally.
3. Guaranteed by design.
4. Minimal impedance on P ON/OFF pin is 1 kW
5. Minimal resistance connected in series with bootstrap diode is 3.3 W
www.onsemi.com
7
NCP1399 Series
ELECTRICAL CHARACTERISTICS
(For typical values T = 25°C, for min/max values T = −40°C to +125°C, V = 12 V unless otherwise noted.)
J
J
CC
Symbol
Start−up Sequence Parameters
Rating
Pin
Min
Typ
Max
Unit
K
Soft−Start increment division ratio (NCP1399AA,
NCP1399BA, NCP1399AK)
12, 14
−
4
−
−
SS_INCREMENT
Soft−Start increment division ratio (NCP1399AL)
Soft−Start increment division ratio (NCP1399AC,
12, 14
12, 14
−
−
2
8
−
−
−
−
NCP1399AF, NCP1399AG, NCP1399AH, Ncp1399AI,
NCP1399AJ, NCP1399AM, NCP1399AN, NCP1399AP)
t
Time duration to restart IC if start−up phase is not finished
12, 14
0.45
0.50
0.55
ms
WATCHDOG
Feedback Section
R
Internal pull−up resistor on FB pin
5
5
5
5
15
18
25
kW
−
FB
FB
K
V
FB
to internal current set point division ratio
1.92
4.60
4.4
2.00
4.95
4.6
2.08
5.30
4.8
V
Internal voltage reference on the FB pin
V
FB_REF
V
Internal clamp on FB input of On−time comparator referred
to external FB pin voltage
V
FB_CLAMP
V
Feedback voltage thresholds to enters in skip mode for
NCP1399By version (Note 2)
5
5
0.44
130
0.50
160
0.56
200
V
FB_SKIP_IN
V
mV
Skip comparator hysteresis (NCP1399AA, NCP1399BA,
NCP1399AC, NCP1399AG, NCP1399AH, NCP1399AK,
NCP1399AM, NCP1399AP)
FB_SKIP_HYST
Skip comparator hysteresis (NCP1399AF, NCP1399AJ,
NCP1399AL)
5
105
140
175
Skip comparator hysteresis (NCP1399AI, NCP1399AN)
5
0
23
50
st
t
On−time duration of 1 Mlower pulse when FB cross
5, 12
0.95
1.05
1.15
ms
ms
1st_MLOWER_SKIP
V
+ V
threshold (NCP1399AA,
FB_SKIP_IN
FB_SKIP_HYST
NCP1399BA, NCP1399AK, NCP1399AL)
st
On−time duration of 1 Mlower pulse when FB cross
5, 12
5, 12
1.8
1.9
2.1
V
+ V
threshold (NCP1399AC,
FB_SKIP_IN
FB_SKIP_HYST
NCP1399AG, NCP1399AI, NCP1399AM, NCP1399AN,
NCP1399AP)
st
On−time duration of 1 Mlower pulse when FB cross
1.08
1.20
1.32
ms
V
+ V
threshold (NCP1399AF,
FB_SKIP_IN
FB_SKIP_HYST
NCP1399AJ)
st
On−time duration of 1 Mlower pulse when FB cross
5, 12
2.1
−
2.4
2.7
−
ms
V
+ V
threshold (NCP1399AH)
FB_SKIP_IN
FB_SKIP_HYST
st
V
Internal FB level reduction during 1 Mupper pulse when FB
5, 6, 14
150
mV
1st_MUPPER_SKIP
cross V
+ V
threshold (NCP1399AA,
FB_SKIP_IN
FB_SKIP_HYST
NCP1399BA, NCP1399AC, NCP1399AG, NCP1399AI,
NCP1399AK, NCP1399AL, NCP1399AM, NCP1399AN,
NCP1399AP) (Note 3)
st
Internal FB level reduction during 1 Mupper pulse when FB
5, 6, 14
5, 6, 14
−
−
100
0
−
−
mV
mV
cross V
+ V
threshold (NCP1399AF,
FB_SKIP_IN
FB_SKIP_HYST
NCP1399AJ) (Note 3)
st
FB_SKIP_HYST
Internal FB level reduction during 1 Mupper pulse when FB
cross V + V threshold
FB_SKIP_IN
(NCP1399AH) (Note 3)
Skip Input – NCP1399Ay version
Internal Skip pin current source
I
4
4
48
−
50
−
52
10
mA
SKIP
C
Maximum loading capacitance for skip pin voltage filtering
(Note 3)
nF
SKIP_LOAD_MAX
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
2. The NCP1399Ay version has skip adjustable externally.
3. Guaranteed by design.
4. Minimal impedance on P ON/OFF pin is 1 kW
5. Minimal resistance connected in series with bootstrap diode is 3.3 W
www.onsemi.com
8
NCP1399 Series
ELECTRICAL CHARACTERISTICS
(For typical values T = 25°C, for min/max values T = −40°C to +125°C, V = 12 V unless otherwise noted.)
J
J
CC
Symbol
Current Sense Input Section
On−time comparator delay to Mupper driver turn off
Rating
Pin
Min
Typ
Max
Unit
t
5, 6
−
−
250
ns
pd_CS
V
FB
= 2.5 V, V goes up from –2.5 V to 2.5 V with rising
CS
edge of 100 ns
I
Current sense input leakage current for V
=
3 V
6
6
−
−
1
mA
CS_LEAKAGE
CS
V
Current sense input offset voltage (NCP1399AA,
160
200
240
mV
CS_OFFSET
NCP1399BA, NCP1399AC, NCP1399AG, NCP1399AH,
NCP1399AI, NCP1399AK, NCP1399AL, NCP1399AM,
NCP1399AN, NCP1399AP)
Current sense input offset voltage (NCP1399AF, NCP1399AJ)
Leading edge blanking time of the on−time comparator output
6
110
360
150
440
190
540
mV
ns
t
5, 6, 14
LEB
Faults and Auto−Recovery Timer
t
FB fault timer duration (NCP1399AA, NCP1399BA,
NCP1399AK, NCP1399AL)
−
−
160
80
200
100
240
120
ms
ms
FB_FAULT_TIMER
FB fault timer duration (NCP1399AC, NCP1399AF,
NCP1399AG, NCP1399AI, NCP1399AJ, NCP1399AM,
NCP1399AN, NCP1399AP)
FB fault timer duration (NCP1399AH)
−
−
5
−
6
240
−
300
1000
4.7
5
360
−
ms
−
N
Number of DRV pulses to confirm FB fault
FB voltage when FB fault is detected
FB_FAULT_COUNTER
V
4.5
−
4.9
−
V
FB_FAULT
CS_FAULT_COUNTER
N
Number of CS_fault cmp. pulses to confirm CS fault
−
V
CS voltage when CS fault is detected (NCP1399AA,
NCP1399BA, NCP1399AC, NCP1399AF, NCP1399AH,
NCP1399AI, NCP1399AK, NCP1399AL, NCP1399AM,
NCP1399AN, NCP1399AP)
V
CS_FAULT
2.5
3.2
2.7
3.4
2.9
3.6
(NCP1399AG)
(NCP1399AJ)
1.85
2.00
2.15
t
s
Auto−recovery duration, common timer for all fault condition
(NCP1399AA, NCP1399BA, NCP1399AC, NCP1399AG,
NCP1399AH, NCP1399AJ, NCP1399AK, NCP1399AL,
NCP1399AM, NCP1399AP)
−
−
0.8
1
1.2
A−REC_TIMER
Auto−recovery duration, common timer for all fault condition
(NCP1399AI, NCP1399AN)
1.6
1.9
2.4
Brown−Out Protection
V
Brown−out turn−off threshold
3
3
3
3
3
0.965
4.3
5
1.000
5.0
12
1.035
5.4
V
BO
I
Brown−out hysteresis current, V
< V
mA
mV
mA
ms
BO
VBULK/PFC_FB
BO
V
Brown*Out comparator hysteresis
Brown*Out input bias current
BO filter duration
25
BO_HYST
BO_BIAS
I
−
−
0.05
30
t
10
20
BO_FILTR
Ramp Compensation
RC
Ramp compensation gain (NCP1399AA, NCP1399BA,
NCP1399AC, NCP1399AF NCP1399AG, NCP1399AK,
NCP1399AM)
mV/ms
GAIN
−
58
82
108
Ramp compensation gain (NCP1399AI, NCP1399AN)
Ramp compensation gain (NCP1399AJ)
Ramp compensation gain (NCP1399AH)
Ramp compensation gain (NCP1399AL)
82
92
107
110
125
149
166
131
150
168
185
116
t
Ramp compensation time shift
−
−
0.6
−
ms
RC_SHIFT
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
2. The NCP1399Ay version has skip adjustable externally.
3. Guaranteed by design.
4. Minimal impedance on P ON/OFF pin is 1 kW
5. Minimal resistance connected in series with bootstrap diode is 3.3 W
www.onsemi.com
9
NCP1399 Series
ELECTRICAL CHARACTERISTICS
(For typical values T = 25°C, for min/max values T = −40°C to +125°C, V = 12 V unless otherwise noted.)
J
J
CC
Symbol
Temperature Shutdown Protection
Rating
Pin
Min
Typ
Max
Unit
T
TSD
Temperature shutdown T going up (NCP1399AA,
NCP1399BA, NCP1399AH, NCP1399AK)
−
−
−
−
124
137
−
−
°C
°C
J
Temperature shutdown T going up (NCP1399AC,
J
NCP1399AF, NCP1399AG, NCP1399AI, NCP1399AJ,
NCP1399AL, NCP1399AM, NCP1399AN, NCP1399AP)
T
Temperature shutdown hysteresis
−
−
30
−
°C
TSD_HYST
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
2. The NCP1399Ay version has skip adjustable externally.
3. Guaranteed by design.
4. Minimal impedance on P ON/OFF pin is 1 kW
5. Minimal resistance connected in series with bootstrap diode is 3.3 W
www.onsemi.com
10
NCP1399 Series
IC Options
Option
Cumulative
FB fault
timer/
Dedicated
Soft_start_-
seq
FB fault
source
TON_MAX
fault
FB fault
counter
CS_FAULT
OVP fault
Latch
OTP fault
Auto−recovery
Auto−recovery
Latch
NCP1399AA Auto−recovery
NCP1399BA Auto−recovery
NCP1399AC Auto−recovery
Timer
Timer
Timer
Timer
Timer
Timer
Timer
Timer
Timer
Timer
Timer
Timer
Timer
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
Auto−recovery Auto−recovery
Auto−recovery Auto−recovery
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Latch
Auto−recovery
Latch
OFF
Latch
OFF
Latch
NCP1399AF
Latch
Latch
Latch
NCP1399AG Auto−recovery
NCP1399AH Auto−recovery
NCP1399AI Auto−recovery
NCP1399AJ Auto−recovery
NCP1399AK Auto−recovery
NCP1399AL Auto−recovery
NCP1399AM Auto−recovery
NCP1399AN Auto−recovery
NCP1399AP Auto−recovery
Auto−recovery
Latch
Auto−recovery
Auto−recovery
Auto−recovery Auto−recovery
Latch
Auto−recovery Auto−recovery Auto−recovery Auto−recovery
Auto−recovery Auto−recovery
Auto−recovery Auto−recovery
Auto−recovery Auto−recovery
Latch
Latch
Latch
Latch
Latch
Auto−recovery
Auto−recovery
Latch
Auto−recovery
Auto−recovery
Auto−recovery
OFF
OFF
OFF
Auto−recovery Auto−recovery
Auto−recovery Auto−recovery
PFC_MODE Dead time
Dead time
fault
OFF−mode
version
OFF−mode
status
Ramp comp P ON/OFF
skip status
control
status
pull−up
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Option
BO status
ON
NCP1399AA
NCP1399BA
NCP1399AC
NCP1399AF
NCP1399AG
NCP1399AH
NCP1399AI
NCP1399AJ
NCP1399AK
NCP1399AL
NCP1399AM
NCP1399AN
NCP1399AP
ON
Auto−recovery
Auto−recovery
Auto−recovery
OFF
Active OFF
Active ON
Active OFF
Active OFF
−
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
Auto−recovery
OFF
ON
Active OFF
Active OFF
Active OFF
Active OFF
Active OFF
Active OFF
Active OFF
Active OFF
ON
ZVS or
DT_max
Without ramp
shift
ON
Auto−recovery
OFF
ON
OFF
OFF
ON
ON
Auto−recovery
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
www.onsemi.com
11
NCP1399 Series
ORDERING INFORMATION
Part Number
†
Marking
Package
Shipping
NCP1399AADR2G
NCP1399BADR2G
NCP1399ACDR2G
NCP1399AFDR2G
NCP1399AGDR2G
NCP1399AHDR2G
NCP1399AIDR2G
NCP1399AJDR2G*
NCP1399AKDR2G
NCP1399ALDR2G*
NCP1399AMDR2G
NCP1399ANDR2G
NCP1399APDR2G
NCP1399AA
NCP1399BA
NCP1399AC
NCP1399AF
NCP1399AG
NCP1399AH
NCP1399AI
NCP1399AJ
NCP1399AK
NCP1399AL
NCP1399AM
NCP1399AN
NCP1399AP
SOIC−16
(Pb−Free)
2500 / Tape & Reel
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
*Available upon request.
www.onsemi.com
12
NCP1399 Series
TYPICAL CHARACTERISTICS
0.30
0.25
0.20
0.15
0.10
1.05
0.95
0.85
0.75
0.65
0.55
0.45
0.05
0
−55
−25
5
35
65
95
125
125
125
−55
−25
5
35
65
95
125
125
125
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 5. ISTART_OFF vs. Temperature
Figure 6. VCC_INHIBIT vs. Temperature
0.55
0.54
0.53
0.52
9.4
9.3
9.2
9.1
9.0
8.9
8.8
0.51
0.50
8.7
8.6
−55
−25
5
35
65
95
−55
−25
5
35
65
95
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 7. ISTART1 vs. Temperature
Figure 8. ISTART2 vs. Temperature
9.45
9.43
9.41
15.85
15.80
15.75
9.39
9.37
15.70
15.65
−55
−25
5
35
65
95
−55
−25
5
35
65
95
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 9. VCC_OFF vs. Temperature
Figure 10. VCC_ON vs. Temperature
www.onsemi.com
13
NCP1399 Series
TYPICAL CHARACTERISTICS
6.48
6.47
6.46
6.45
820
800
780
760
740
6.44
6.43
720
700
−55
−25
5
35
65
95
125
125
125
−55
−25
5
35
65
95
125
125
125
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 11. VCC_RESET vs. Temperature
Figure 12. ICC_SKIP−MODE vs. Temperature
485
465
445
425
7.0
6.8
6.6
6.4
6.2
6.0
405
385
−55
−25
5
35
65
95
−55
−25
5
35
65
95
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 13. ICC_AUTOREC vs. Temperature
Figure 14. ICC_OPERATION vs. Temperature
475
455
435
35
32
29
26
415
395
23
20
−55
−25
5
35
65
95
−55
−25
5
35
65
95
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 15. ICC_LATCH vs. Temperature
Figure 16. ICC_OFF−MODE vs. Temperature
www.onsemi.com
14
NCP1399 Series
TYPICAL CHARACTERISTICS
9.20
9.15
9.10
9.05
9.00
8.4
8.3
8.2
8.1
8.0
7.9
8.95
8.90
−55
−25
5
35
65
95
125
−55
−25
5
35
65
95
125
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 17. VBOOT_ON vs. Temperature
Figure 18. VBOOT_OFF vs. Temperature
1.72
1.70
1.202
1.197
1.192
1.68
1.66
1.64
1.62
1.187
1.182
1.60
1.58
−55
−25
5
35
65
95
125
−55
−25
5
35
65
95
125
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 19. IBOOT2 vs. Temperature
Figure 20. VCLAMP_OVP/OTP_1 vs. Temperature
0.804
0.802
0.800
0.798
0.796
2.520
2.515
2.510
2.505
2.500
2.495
0.794
0.792
2.490
2.485
−55
−25
5
35
65
95
125
−55
−25
5
35
65
95
125
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 21. VOTP vs. Temperature
Figure 22. VOVP vs. Temperature
www.onsemi.com
15
NCP1399 Series
TYPICAL CHARACTERISTICS
96.0
95.5
95.0
94.5
94.0
22
21
20
19
18
17
16
93.5
93.0
−55
−25
5
35
65
95
125
125
125
−55
−25
5
35
65
95
125
125
125
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 23. IOTP vs. Temperature
Figure 24. RFB vs. Temperature
8.1
8.0
7.9
204
203
202
201
7.8
7.7
200
199
7.6
7.5
−55
−25
5
35
65
95
−55
−25
5
35
65
95
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 25. tON_MAX vs. Temperature
Figure 26. VCS_OFFSET vs. Temperature
185
175
165
155
2.72
2.71
2.70
2.69
145
135
2.68
2.67
−55
−25
5
35
65
95
−55
−25
5
35
65
95
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 27. tpd_CS vs. Temperature
Figure 28. VCS_FAULT vs. Temperature
www.onsemi.com
16
NCP1399 Series
TYPICAL CHARACTERISTICS
1.010
1.005
1.000
5.00
4.95
4.90
4.85
0.995
0.990
4.80
4.75
−55
−25
5
35
65
95
125
125
125
−55
−25
5
35
65
95
125
125
125
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 29. VBO vs. Temperature
Figure 30. IBO vs. Temperature
4.70
4.69
4.68
4.67
4.66
50.2
50.0
49.8
49.6
49.4
4.65
4.64
49.2
49.0
−55
−25
5
35
65
95
−55
−25
5
35
65
95
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 31. VFB_FAULT vs. Temperature
Figure 32. ISKIP vs. Temperature
78
76
74
16
14
12
72
70
10
8
−55
−25
5
35
65
95
−55
−25
5
35
65
95
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 33. RCGAIN vs. Temperature
Figure 34. IDISCHARGE1 vs. Temperature
www.onsemi.com
17
NCP1399 Series
TYPICAL CHARACTERISTICS
28
24
20
16
10
8
6
4
2
12
8
−55
−25
5
35
65
95
125
−55
−25
5
35
65
95
125
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 35. ROH vs. Temperature
Figure 36. ROL vs. Temperature
www.onsemi.com
18
NCP1399 Series
VCC Management with High−voltage Startup Current Source
The NCP1399 controller features a HV startup current
source that allows fast startup time and extremely low
standby power consumption. Two startup current levels
failure mode that may occur in the application. The HV
startup current source is primarily enabled or disabled based
on V level. The startup HV current source can be also
CC
(I
and I
) are provided by the system for safety in
enabled by BO_OK rising edge, auto−recovery timer end,
REMote and TSD end event. The HV startup current source
charges the VCC capacitor before IC start−up.
start1
start2
case of short circuit between VCC and GND pins. In
addition, the HV startup current source features a dedicated
over−temperature protection to prevent IC damage for any
Figure 37. Internal Connection of the VCC Management Block
The NCP1399 controller disables the HV startup current
Figure 65 to find an illustration of the NCP1399 VCC
management system under all operating conditions/modes.
The HV startup current source features an independent
source once the VCC pin voltage level reaches V
CC_ON
threshold – refer to Figure 37. The application then starts
operation and the auxiliary winding maintains the voltage
bias for the controller during normal and skip−mode
operating modes. The IC operates in so called Dynamic Self
Supply (DSS) mode when the bias from auxiliary winding
over–temperature protection system to limit I
current
start2
when the die temperature reaches 130°C. At this
temperature, I will be progressively to prevent the die
start2
temperature from rising above 130°C.
is not sufficient to keep the V voltage above V
CC
CC_OFF
Brown−out Protection − VBULK/PFC FB Input
threshold (i.e. V voltage is cycling between V
and
CC
CC_ON
Resonant tank of an LLC converter is always designed to
operate within a specific bulk voltage range. Operation
below minimum bulk voltage level would result in current
and temperature overstress of the converter power stage.
The NCP1399 controller features a VBULK/PFC FB input
in order to precisely adjust the bulk voltage turn−ON and
turn−OFF levels. This Brown−Out protection (BO) greatly
simplifies application level design.
V
thresholds with no driver pulses on the output
CC_OFF
during positive V ramp). The HV source is also operated
in DSS mode when the low voltage controller enters
off−mode or fault−mode operation. In this case the VCC pin
CC
voltage will cycle between V
and V
CC_ON
CC_OFF
thresholds and the controller will not deliver any driver
pulse – waiting for return from the off−mode or latch mode
operation. Please refer to figures Figure 61 through
www.onsemi.com
19
NCP1399 Series
Figure 38. Internal Connection of the Brown−out Protection Block
The internal circuitry shown in Figure 38 allows
Note that the VBULK/PFC FB pin is pulled down by an
internal switch when the controller is in startup phase − i.e.
monitoring the high−voltage input rail (V ).
A
bulk
high−impedance resistive divider made of R
and R
when the V voltage ramps up from V < V
upper
lower
CC CC CC_RESET
resistors brings a portion of the V
rail to the
towards the V
level on the VCC pin. This feature
bulk
CC_ON
VBULK/PFC FB pin. The Current sink (I ) is active below
assures that the VBULK/PFC FB pin voltage will not ramp
BO
the bulk voltage turn−on level (V
). Therefore, the
up before the IC operation starts. The I hysteresis current
bulk_ON
BO
bulk voltage turn−on level is higher than defined by the
division ratio of the resistive divider. To the contrary, when
the internal BO_OK signal is high, i.e. the application is
sink is activated and BO discharge switch is disabled once
the
V
CC
voltage crosses
V
CC_ON
threshold. The
VBULK/PFC FB pin voltage then ramps up naturally
according to the BO divider information. The BO
comparator then authorizes or disables the LLC stage
running, the I sink is disabled. The bulk voltage turn−off
BO
threshold (V ) is then given by BO comparator
bulk_OFF
reference voltage directly on the resistor divider. The
advantage of this solution is that the V threshold
operation based on the actual V
level.
bulk
The low I hysteresis current of the NCP1399 brown out
bulk_OFF
BO
precision is not affected by I
tolerance.
hysteresis current sink
protection system allows increasing the bulk voltage divider
resistance and thus reduces the application power
consumption during light load operation. On the other hand,
the high impedance divider can be noise sensitive due to
capacitive coupling to HV switching traces in the
BO
The V
and V
levels can be calculated
bulk_ON
bulk_OFF
using equations below:
The I is ON:
BO
application. This is why a filter (t
) is added after the
BO_FILTR
(eq. 1)
VBO ) VBOhyst
+
BO comparator in order to increase the system noise
immunity. Despite the internal filtering, it is also
recommended to keep a good layout for BO divider resistors
and use a small external filtering capacitor on the
VBULK/PFC pin if precise BO detection wants to be
achieved.
The bulk voltage HV divider can be also used by a PFC
front stage controller as a feedback sensing network (refer
again to Figure 38). The shared bulk voltage resistor divider
between PFC and LLC stage offers a way how to further
reduce power losses during off−mode and no−load
operation. The NCP1399 features a PFC MODE pin that
disconnects bias of the PFC stage during light load,
off−mode or fault mode operation. The signal from the PFC
MODE pin can be also used to control an external HV switch
in order to disconnect the bulk voltage divider from bulk
during off−mode operation. This technique further reduces
Rlower
Rlower ) Rupper
Rlower @ Rupper
Rlower ) Rupper
@ ǒ
Ǔ
Vbulk_ON
@
* IBO
The I is OFF:
BO
Rlower
Rlower ) Rupper
VBO + Vbulk_OFF
@
(eq. 2)
One can extract R
term from equation 2 and use it in
lower
equation 1 to get needed R
value:
upper
Vbulk_ON@V
BO * VBO * VBOhyst
Vbulk_OFF
Rlower
+
(eq. 3)
(eq. 4)
VBO
IBO
@
ǒ
1 *
Ǔ
Vbulk_OFF
Vbulk_OFF * VBO
Rupper + Rlower
@
VBO
www.onsemi.com
20
NCP1399 Series
the no−load power consumption down again since the power
losses of voltage divider are not affected by the bulk voltage
at all.
Please refer to Figure 61 through Figure 65 for an
illustration of NCP1399 Brown−out protection system in all
operating conditions/modes.
the operation, after filter time delay, when the OVP/OTP
input voltage is out of the no−fault window. The controller
then either latches−off or or starts an auto−recovery timer −
depending on the IC version − and triggered the protection
threshold (V
or V ).
OVP
OTP
The internal current source I
allows a simple OTP
OTP
implementation by using a single negative temperature
coefficient (NTC) thermistor. An active soft clamp
Over−voltage and Over−temperature Protection
The OVP/OTP pin is a dedicated input to allow for a
simple and cost effective implementation of two key
protection features that are needed in adapter applications:
over−voltage (OVP) and over−temperature (OTP)
protections. Both of these protections can be either latched
or auto−recovery– depending on the version of NCP1399.
The OVP/OTP pin has two voltage threshold levels of
composed from V
and R
components prevents the
clamp
clamp
OVP/OTP pin voltage from reaching the V
threshold
OVP
when the pin is pulled up by the I
current. An external
OTP
pull−up current, higher than the pull*down capability of
the internal clamp (V
pull the OVP/OTP pin above V
), has to be applied to
threshold to activate the
CLAMP_OVP/OTP
OVP
OVP protection. The t
and t
filters
OVP_FILTER
OTP_FILTER
detection (V
and V ) that define a no−fault window.
OTP
OVP
are implemented in the system to avoid any false triggering
of the protections due to application noise and/or poor
layout.
The controller is allowed to run when OVP/OTP input
voltage is within this working window. The controller stops
Figure 39. Internal Connection of OVP/OTP Input
The OTP protection could be falsely triggered during
controller startup due to the external filtering capacitor
• IC returns to operation from skip−mode (V
+
FB_SKIP_IN
V
threshold was reached)
FB_SKIP_HYST
charging current. Thus the t
period has been
BLANK_OTP
• IC returns to operation from off−mode (V
or
REM_ON
implemented in the system to overcome such behavior. The
OTP comparator output is ignored during t
V
signal is received by off−mode control
FB_REM_ON
BLANK_OTP
block)
period. In order to speed up the charging of the external
filtering capacitor C connected to OVP/OTP pin,
The I
current source is disabled when:
OTP
OVP_OTP
• V falls below V
threshold
CC
CC_OFF
the I
current has been doubled to I . The
OTP_BOOST
OTP
• BO OK signal goes to low state (i.e. Brown−out
condition occurs on the mains)
maximum value of filtering capacitor is 47 nF.
The OVP/OTP ON signal is set after the following events:
• the V voltage exceeds the V threshold during
• Fault signal is activated (Auto−recovery timer starts
counting or Latch fault is present)
CC
CC_ON
first start−up phase (after VCC pin voltage was below
threshold)
• IC goes into the skip−mode operation (V
V
FB_SKIP_IN
CC_RESET
threshold was reached)
• BO OK signal is received from BO block
• Auto−recovery timer elapsed and a new restart occurs
• IC goes into the off−mode operation (V
or
REM_OFF
) signal was reached)
(V
& V
FB_REM_OFF
CC_OFF
www.onsemi.com
21
NCP1399 Series
The latched OVP or OTP versions of NCP1399 enters
latched protection mode when V voltage cycles between
• Active OFF off−mode control − available on the
CC
NCP1399Ay device family
V
CC_ON
and V
thresholds and no pulses are provided
CC_OFF
These two off−mode operation control techniques differ in
the way the off−mode operation is started on the primary
side controller. Both of these methods are described
separately hereinafter.
by drivers. The controller VCC pin voltage has to be cycled
down below V threshold in order to restart
CC_RESET
operation. This would happen when the power supply is
unplugged from the mains.
Active ON Off−mode Control – NCP1399B Device
Family
SKIP/REM Input and Off−mode Control
The NCP1399 implements an ultra−low power
consumption mode of operation called off−mode. The
application output voltage is cycled between the nominal
and lower levels that are defined by the secondary side
off−mode controller (like NCP435x secondary off−mode
controller). The output voltage is thus not regulated to
nominal level but is always kept at a high enough voltage
level to provide bias for the necessary circuits in the target
application – for example this could be the case of
microcontroller with very low consumption that handles
VCC management in a notebook or TV. The no−load input
power consumption could be significantly reduced when
using described technique. The NCP1399 implements two
different off−mode control system approaches:
The NCP1399B device family uses a SKIP/REM pin only
for off−mode operation control– i.e. the pin is internally
connected to the Active ON off−mode control block and the
skip mode threshold level is not adjustable externally. The
skip mode comparator threshold can be adjusted only
internally (by IC option) in this package option. The
SKIP/REM pin when used for off−mode control allows the
user to activate the ultra−low consumption mode during
which the IC consumption is reduced to only very low HV
pin leakage current (I ) and very low VCC pin
HV_OFF−MODE
consumption (I
). The off*mode is activated
CC_OFF−MODE
when SKIP/REM pin voltage exceeds V
threshold.
REM_OFF
Normal operating mode is resumed when SKIP/REM pin
voltage drops below V threshold – refer to
REM_ON
• Active ON off−mode control − available on the
Figure 40 for an illustration.
NCP1399By device family
Figure 40. SKIP/REM Input Internal Connection – Active ON Version
The off−mode operation is activated by the secondary side
off−mode controller. The auxiliary bias for primary side
off−mode control is provided by a circuit composed from
switching between ON−mode and OFF−mode states when
off−mode control is implemented. The OFF mode period
last significantly longer time (tens of seconds or more)
compared to the secondary capacitor refilling period (few
tens of milliseconds) – this explains why the no−load input
power consumption can be drastically reduced. The
auxiliary off−mode supply capacitor C1 can stay charged
while the secondary bias is lost – this can happen during
overload or other fault mode conditions. A REM TIMER is
thus implemented in the system to allow fast application
components D , C , R , R and C . The SKIP/REM pin is
2
1
1
2
2
pulled up by this auxiliary supply circuit once the REM
optocoupler (REM OK) is released. The application then
operates in off−mode until the secondary side off−mode
controller activates the REM optocoupler or until the
auxiliary bias on C is lost. Normal operation mode is then
1
recovered via power stage startup. The application is thus
www.onsemi.com
22
NCP1399 Series
restart in such cases. The controller blanks the SKIP/REM
input information and pulls down the SKIP/REM input for
time during controller restart so that the
secondary side bias can be restored and the secondary
off−mode controller can activate the REM optocoupler. This
REM TIMER blank sequence is activated each time the
The bias on VCC pin needs to be assured when off−mode
operation takes place. The auxiliary winding is no more able
to provide any bias thus the HV startup current source is
operated in DSS mode – i.e. the VCC pin voltage is cycling
t
REM_TIMER
between V
and V
thresholds. This approach
CC_ON
CC_OFF
keeps IC biasing in order to memorize the current operation
sate.
VCC pin voltage reaches V
threshold – except in the
CC_ON
situation when after IC left off−mode operation by standard
Please refer to Figure 64 for an illustration on how the
NCP1399 Active ON off−mode system works under all
operating conditions/modes.
way and V is restored – i.e. when the REM optocoupler
CC
is activated by the secondary off−mode controller.
The SKIP/REM input blanking is activated in following
cases:
Active OFF Off−mode Control – NCP1399A Device
Family
The NCP1399A device family uses LLC FB pin voltage
information for off−mode operation detection − refer to
Figure 41. The SKIP/REM pin is internally connected to the
• VCC pin voltage reaches V
threshold during first
CC_ON
start−up phase (i.e. when V was below V
CC
CC_RESET
threshold before)
• Auto−recovery timer elapsed and new start is initiated
skip mode block in this case and serves as a V
FB_SKIP_IN
threshold voltage adjust pin. The secondary off−mode
controller reuses the LLC stage regulation optocoupler in
order to reduce total system cost. The off−mode operation is
initiated once the LLC FB pin is pulled down below
The REM TIMER helps to assure fast application re−start
from fault conditions by forcing controller operation after
t
. However, the secondary controller drives the
REM_TIMER
remote pin via REM optocoupler during normal operating
conditions in order to switch between ON and OFF
operating modes. The controller is active for very short time
during no−load conditions − just during the time needed to
re−fill the secondary side capacitors to the nominal output
voltage level. In this case we do not use REM TIMER
because it would increase the no−load power consumption
by forcing the application to run for a longer time than
necessary. The REM TIMER blank period is thus not
activated in no−load conditions.
V
V
threshold and the VCC pin voltage drops below
threshold in the same time. The optocoupler has to
REM_ON
CC_OFF
be active at all time the application is held in off−mode. No
biased is then provided by the secondary off−mode
controller during normal operation – this is why this
approach is called Active OFF off−mode operation. The
application no−load input power consumption is slightly
higher compared to Active ON off−mode solution,
previously described, because the optocoupler needs to be
biased during off mode operation
Figure 41. Active OFF Off−mode Internal Detection Based on the LLC FB Pin Voltage
The controller monitors the LLC FB pin voltage level and
restarts via regular startup sequence (including VCC pin
voltage is cycling between V
and V
CC_ON CC_OFF
thresholds. This approach keeps IC biased so that the actual
operation sate is memorized. The LLC FB pin pull−up
resistor is disconnected when off−mode operation is
activated in order to reduce IC power consumption and also
needed current for optocoupler driving from secondary side.
voltage ramp−up to V
level and soft−start) once the
CC_ON
FB pin is released by the secondary off−mode controller.
The HV startup current source is working in DSS mode
during application off−mode operation – i.e. the VCC pin
www.onsemi.com
23
NCP1399 Series
Please refer to Figure 65 for an illustration on how the
NCP1399 active ON off−mode system works under all
operating conditions/modes.
P ON/OFF pin is 1 kW. The PFC stage operation can thus be
disabled/enabled via external logic signal. This option
should be used with the wide range input voltage LLC tank
designed to assure correct operation of the LLC stage
through whole bulk voltage range. The PFC MODE output
pin can be used for two purposes:
PFC MODE Output and P ON/OFF Control Pin
The NCP1399 has two pins P ON/OFF and PFC MODE
that can be used to disable or enable PFC stage operation
based on actual application operating state – please refer to
Figure 46. The PFC MODE pin voltage is changed
1. to control the external small signal HV MOSFET
switch that connects the bulk voltage divider to the
VBULK/PFC FB input
2. to control the PFC front stage controller operation
via PFC controller supply pin
(V
or V
) based on the actual P ON/OFF
PFC_M_ON
PFC_M_BO
input logic signal state. Minimum impedance connected to
5 V
0.1 V
Figure 42. Internal Connection of the PFC MODE and P ON/OFF Blocks
There are three possible states of the PFC MODE output
that can be placed by the controller based on the application
operating conditions:
connects VCC pin voltage to PFC MODE output
with minimum dropout (V ). This state of
the PFC MODE output appears in case an external
signal on the P ON/OFF pin is at “low” state.
PFC_M_ON
1. The PFC MODE output pin is pulled−down by an
internal MOSFET switch before controller startup.
This technique ensures minimum VCC pin current
The output power level is derived internally from the
actual FB pin voltage. This information could be compared
on external comparator with the reference level and control
the P ON/OFF input, thus the user has possibility to adjust
power below which the PFC stage is disabled in order to
increase efficiency in light load conditions. The P ON/OFF
consumption in order to ramp V voltage in a
CC
short time from the HV startup current source
which speeds up the startup or restart process. The
PFC MODE output pin is also pulled−down in
off−mode or protection mode during which the HV
startup current source is operated in DSS mode.
This reduces the application power consumption in
both cases.
comparator features an hysteresis (P ON/OFF
)
HYST
proportional to the set P ON/OFF level in order to overcome
PFC power stage oscillations (periodical ON/OFF
2. The pull−down switch is disabled and the internal
regulator enabled by the controller to provide
operation). The P ON/OFF timer (t
) is
P ON/OFF_TIMER
implemented to ensure a long enough propagation delay
from the PFC turn OFF detection to PFC MODE output
deactivation. This timer is unidirectional so that it resets
immediately after PFC ON condition is detected by the
P ON/OFF comparator. This technique is used in order to
avoid a PFC stage deactivation during load or line transients.
The PFC MODE pin output current is limited when the VCC
to PFC MODE bypass switch is activated. The current
limitation avoids bypass switch damage during PFC VCC
decoupling capacitor charging process or short circuit. A
minimum value PFC VCC decoupling capacitance should
be used in order to speed up PFC stage startup after it is
enabled by the NCP1399 controller.
V
reference when an external logic
PFC_M_BO
signal on the P ON/OFF pin is at “high” state. An
internal regulator includes current limitation for
the PFC MODE output that is set to I
PFC_M_LIM
when V
reference is provided. The PFC
PFC_M_BO
MODE pin drives external small signal HV
MOSFET switch to keep bulk voltage divider
connected. The LLC power stage Brown−out
protection system thus works when the LLC stage
is switching while PFC stage disabled.
3. The pull−down switch is disabled and the internal
regulator is switched to bypass mode in which it
www.onsemi.com
24
NCP1399 Series
Please refer to Figure 61 through Figure 65 for an
illustration of NCP1399 PFC operation control.
2. Precise VCO (or CCO) is needed to assure
frequency modulation with good reproducibility,
f
and f
clamps need to be adjusted for each
min
max
ON−time Modulation and Feedback Loop Block
Frequency modulation of today’s commercially available
resonant mode controllers is based on the output voltage
regulator feedback only. The feedback voltage (or current)
of output regulator drives voltage (or current) controlled
oscillator (VCO or CCO) in the controller. This method
presents three main disadvantages:
design ≥ need for an adjustment pin(s).
3. Dedicated overload protection system, requiring
an additional pin, is needed to assure application
safety during overload and/or secondary short
circuit events.
The NCP1399 resolves all disadvantages mentioned
above by implementing a current mode control scheme that
ensures best transient response performance and provides
inherent cycle−by−cycle over−current protection feature in
the same time. The current mode control principle used in
this device can be seen in Figure 43.
nd
1. The 2 order pole is present in small signal
gain−phase characteristics ≥ the lower cross over
frequency and worse transient response is imposed
by the system when voltage mode control is used.
There is no direct link to the actual primary current
– i.e. no line feed forward mechanism which
results in poor line transient response.
Figure 43. Internal Connection of the NCP1399 Current Mode Control Scheme
The basic principle of current mode control scheme
implementation lies in the use of an ON−time comparator
that defines upper switch on−time by comparing voltage
ramp, derived from the current sense input voltage, to the
divided feedback pin voltage. The upper switch on−time is
then re−used for low side switch conduction period. The
switching frequency is thus defined by the actual primary
current and output load conditions. Digital processing with
10 ns minimum on−time resolution is implemented to
ensure high noise immunity. The ON−time comparator
is divided down by capacitive divider (Ccs1, Ccs2, Rcs1,
Rcs2) before it is provided to the CS input. The capacitive
divider division ratio, which is fully externally adjustable,
defines the maximum primary current level that is reached
in case of maximum feedback voltage – i.e. the capacitive
divider division ration defines the maximum output power
of the converter for given bulk voltage. The CS is a bipolar
input pin which an input voltage swing is restricted to 5 V.
A fixed voltage offset is internally added to the CS pin signal
in order to assure enough voltage margin for operation the
feedback optocoupler − the FB optocoupler saturation voltage
is ~ 0.15 V (depending on type). However, the CS pin useful
signal for frequency modulation swings from 0 V, so current
mode regulation would not work under light load conditions
if no offset would be added to the CS pin before it is stabilized
to the level of the on−time comparator input. The CS pin
signal is also used for secondary side short circuit detection
– please refer to chapter dedicated to short circuit protection.
output is blanked by the leading edge blanking (t
) after
LEB
the Mupper switch is turned−on. The ON−time comparator
LEB period helps to avoid false triggering of the on−time
modulation due to noise generated by the HB pin voltage
transition.
The voltage signal for current sense input is prepared
externally via natural primary current integration by the
resonant tank capacitor Cs. The resonant capacitor voltage
www.onsemi.com
25
NCP1399 Series
The second input signal for the on−time comparator is
passes through the FB processing block before it is brought
to the ON−time comparator input. The FB processing block
derived from the FB pin voltage. This internal FB pin signal
is also used for the following purposes: skip mode operation
detection, PFC MODE control, off−mode detection (in
NCP1399A device family) and overload / open FB pin fault
detection. The detailed description of these functions can be
found in each dedicated chapters. The internal pull−up
resistor assures that the FB pin voltage increases when the
optocoupler LED becomes less biased – i.e. when output
load is increased. The higher FB pin voltage implies a higher
reference level for on−time comparator i.e. longer Mupper
switch on−time and thus also higher output power. The FB
pin features a precise voltage clamp which limits the internal
FB signal during overload and startup. The FB pin signal
scales the FB signal down by a K ratio in order to limit the
FB
CS input dynamic voltage range. The scaled FB signal is
then further processed by subtraction of
a ramp
compensation generator signal in order to ensure stability of
the current mode control scheme. The divided internal FB
signal is overridden by a Soft−start generator output voltage
during device starts−up.
The actual operation frequency of the converter is defined
based on the CS pin and FB pin input signals. Please refer to
Figure 44 and below description for better understanding of
the NCP1399 frequency modulation system.
Figure 44. NCP1399 On−time Modulation Principle
The Mupper switch is activated by the controller after
dead−time (DT) period lapses in point A. The frequency
processing block increments the ON−time counter with
10 ns resolution until the internal CS signal crosses the
internal FB set point for the ON−time comparator in point B.
A DT period is then introduced by the controller to avoid any
shoot−through current through the power stage switches.
The DT period ends in point C and the controller activates
the Mlower switch. The ON−time processing block
decrements the ON_time counter down until it reaches zero.
The Mlower switch is then turned−OFF at point D and the
DT period is started. This approach results in perfect duty
cycle symmetry for Mlower and Mupper switches. The
Mupper switch on−time naturally increases and the
operating frequency drops when the FB pin voltage is
increased, i.e. when higher current is delivered by the
converter output – sequence E.
skip mode is not used or adjusted correctly. The current
mode operation is not possible in such case because the
ON−time comparator output stays active for several
switching cycles. Thus a special logic has been implemented
in NCP1399 in order to repeat the last valid on−time until the
current mode operation recovers – i.e. until the CS pin signal
balance is restored by the system.
Overload and Open FB Protections
The overload protection and open FB pin detection are
implemented via FB pin voltage monitoring in this
controller. The FB fault comparator is triggered once the FB
pin voltage reaches its maximum level and the V
FB_FAULT
threshold is exceeded. The fault timer or counter (depending
on IC option) is then enabled – refer to Figure 43. The time
period to the FB fault event confirmation is defined by the
preselected t
parameter when the fault
FB_FAULT_TIMER
timer option is used. The FB fault counter, once selected as
a FB fault confirmation period source, defines the fault
confirmation period via Mupper DRV pulses counting. The
The resonant capacitor voltage and thus also CS pin
voltage can be out of balance in some cases – this is the case
during transition from full load to no−load operation when
www.onsemi.com
26
NCP1399 Series
FB fault confirmation time is thus dependent on switching
option is also available on request. The FB fault
timer/counter is not reset when the FB fault condition
diminishes in this case. The FB fault timer/counter is
disabled and memorizes the fault period information. The
cumulative FB fault timer/counter integrates all the FB fault
events over the IC operation time. The Fault timer/counter
can be reset via skip mode or VCC UVLO event.
frequency. The fault timer/counter is reset once the FB fault
condition diminishes. A digital noise filter has been added
after the FB fault comparator to overcome false triggering of
the FB fault timer/counter due to possible noise on the FB
input. The noise filter has a period of 2 ms for FB fault
timer/counter activation and 20 ms for reset/deactivation to
assure high noise immunity. A cumulative timer/counter IC
Figure 45. Internal FB Fault Management
The controller disables driver pulses and enters protection
mode once the FB fault event is confirmed by the FB fault
timer or counter. Latched or auto−recovery operation is then
triggered – depends on selected IC option. The controller
primary current is naturally limited by the NCP1399
on−time modulation principle in this case. But the primary
current increases when the output terminals are shorted. The
NCP1399 controller will maintain zero voltage switching
operation in such case, however high currents will flow
through the power MOSFETS, transformer winding and
secondary side rectification. The NCP1399 implements a
dedicated secondary side short circuit protection system that
will shut down the controller much faster than the regular FB
fault event in order to limit the stress of the power stage
components. The CS pin signal is monitored by the
dedicated CS fault comparator − refer to Figure 43. The CS
fault counter is incremented each time the CS fault
comparator is triggered. The controller enters
auto−recovery or latched protection mode (depending on IC
option) in case the CS fault counter overflows refer to
Figure 46. The CS fault counter is then reset once the CS
fault comparator is inactive for at least 50 Mupper upcoming
pulses. This digital filtering improves CS fault protection
system noise immunity.
adds an auto−recovery off−time period (t ) and
A−REC_TIMER
restarts the operation via soft start in case of auto−recovery
option. The application temperature runaway is thus
avoided in case of overload while the automatic restart is still
possible once the overload condition disappears. The IC
with latched FB fault option stays latched−off, supplied by
the HV startup current source working in DSS mode, until
the V
threshold is reached on the VCC pin – i.e.
CC_RESET
until user re−connects power supply mains.
Please refer to Figure 61 and Figure 62 for an illustration
of the NCP1399 FB fault detection block.
Secondary Short Circuit Detection
The protection system described previously, implemented
via FB pin voltage level detection, prevents continuous
overload operation and/or open FB pin conditions. The
www.onsemi.com
27
NCP1399 Series
Figure 46. NCP1399 CS Fault Principle
Dedicated Startup Sequence and Soft−Start
Hard switching conditions can occur in a resonant SMPS
application when the resonant tank operation is started with
50% duty cycle symmetry – refer to Figure 47. This hard
switching appears because the resonant tank initial
conditions are not optimal for the clean startup.
Figure 47. Hard switching cycle appears in the LLC application when resonant tank is
excited by 50% duty cycle during startup
The initial resonant capacitor voltage level can differ
resonant tank is low when the output is loaded and/or the
output voltage is low enough to made secondary rectifies
conducting during first switching cycles of startup phase.
The resonant frequency of the resonant tank is given by the
resonant capacitor capacitance and resonant inductance
−note that the magnetizing inductance does not participate
in resonance in this case. However, if the application
starts−up when the output capacitors is charged and there is
no load connected to the output, the secondary rectification
diodes is not conducting during each switching cycle of
startup sequence and thus the resonant frequency of resonant
tank is affected also by the magnetizing inductance. In this
case, the resonant frequency is much lower than in case of
startup into loaded/discharged output.
depending on how long delay was placed before application
operation restart. The resonant capacitor voltage is close to
zero level when application restarts after very long delay –
for example several seconds, when the resonant capacitor is
discharged by leakage to the power stage. However, the
resonant capacitor voltage value can be anywhere between
Vbulk and 0 V when the application restarts operation after
a short period of time – like during periodical SMPS
turn−on/off. Another factor that plays significant role during
resonant power supply startup is the actual load impedance
seen by the power stage during the first pulses of startup
sequence. This impedance is not only defined by resonant
tank components but also by the output loading conditions
and actual output voltage level. The load impedance of
www.onsemi.com
28
NCP1399 Series
These facts show that a clean, hard switching free and
charged before the first high−side driver pulse is introduced
by the controller. The first Mupper switch on−time Tup1
period is fixed and depends on the application parameters.
This period can be adjusted internally – various IC options
parasitic oscillation free, startup of an LLC converter is not
an easy task, and cannot be achieved by duty cycle imbalance
and/or simple resonant capacitor pre−charge to Vbulk/2 level.
These methods only work in specific startup conditions.
This explains why the NCP1399 implements a proprietary
startup sequence − see Figure 48 and Figure 49. The resonant
capacitor is discharged down to 0 V before any application
restart − except when restarting from skip mode.
are available. The Mupper switch is released after T
up1
period and it is not followed by the Mlower switch
activation. The controller waits for a new ZVS condition for
Mupper switch instead and measures actual resonant tank
conditions this way. The Mupper switch is then activated
again after the Mlower blank period is used for measurment
purposes. The second Mupper driver conduction period is
then dependent on the previously measured conditions:
1. The Mupper switch is activated for 3/2 of previous
Mupper conduction period in case the measured
time between previous Mupper turn−off event and
upper ZVS condition detection is twice higher than
the the previous Mupper pulse conduction period
2. The Mupper switch is activated for previous
Mupper conduction period in case the measured
time between previous Mupper turn−off event and
upper ZVS condition detection is twice lower than
the previous Mupper pulse conduction period
The startup period then depends on the previous
condition. Another blank Mlower switch period is placed by
the controller in case condition 1 occurred. A normal
Mlower driver pulse, with DC of 50% to previous Mupper
DRV pulse, is placed in case condition 2 is fulfilled.
The dedicated startup sequence is placed after the
resonant capacitor is discharged (refer to Figure 48 and
Figure 49) in order to exclude any hard switching cycles
during the startup sequence. The first Mupper switch cycle
in startup phase is always non−ZVS cycle because there is
no energy in the resonant tank to prepare ZVS condition.
However, there is no energy in the resonant tank at this time,
there is also no possibility that the power stage MOSFET
body diodes conducts any current. Thus the hard
commutation of the body diode cannot occur in this case.
The IC will not start and provide regular driver output
pulses until it is placed into the target application, because
the startup sequence cannot be finished until HB pin signal
is detected by the system. The IC features a startup watchdog
Figure 48. Initial Resonant Capacitor Discharge
before Dedicated Startup Sequence is Placed
timer (t
) which activates a dedicated startup
WATCHDOG
Figure 49. Dedicated Startup Sequence Detail
sequence periodically in case the IC is powered without
application (during bench testing) or in case the startup
sequence is not finished correctly. The IC will provide the
first Mlower and first Mupper DRV pulses with a
The resonant capacitor discharging process is simply
implemented by activating an internal current limited switch
connected between the HB pin and IC ground – refer to
Figure 48. This technique assures that the resonant capacitor
energy is dissipated in the controller without ringing or
oscillations that could swing the resonant capacitor voltage
to a positive or negative level. The controller detects that the
discharge process is complete via HB pin voltage level
monitoring. The discharge switch is disabled once the HB
t
off−time in−between startup attempts.
WATCHDOG
Soft−start
The dedicated startup sequence is complete when
condition 2 from previous chapter is fulfilled and the
controller continues operation with the soft−start sequence.
A fully digital non−linear soft−start sequence has been
implemented in NCP1399 using a soft−start counter and
D/A converter that are gradually incremented by the Mlower
driver pulses. A block diagram of the NCP1399 soft−start
system is shown in Figure 50.
pin voltage drops below the V
threshold.
HB_MIN
The dedicated startup sequence continues by activation of
the Mlower driver output for Tl1 period (refer to Figure 49).
This technique ensures that the bootstrap capacitor is fully
www.onsemi.com
29
NCP1399 Series
Figure 50. Soft−start Block Internal Implementation
The soft−start block subsystems and operation are
described below:
1. The Soft−Start counter is a unidirectional counter
power switches as afore mentioned. The ON−time
counter count−up mode can be switched to the
count−down mode by either of two events: 1
st
that is loaded with the last Mupper on−time value
that is reached at the dedicated startup sequence
end (i.e. during condition b occurrence explained
in previous chapter). The on−time period used in
the initial period of the soft−start sequence is
affected by the first Mupper on−time period
selection and the dedicated startup sequence
processing. The Soft−Start counter counts up from
this initial on time period to its maximum value
which corresponds to the IC maximum on−time.
The Soft−Start counter is incremented by the
when the ON−time counter value reaches the
nd
maximum on−time value (t
) or 2 when
TON_MAX
the actual Mupper on−time is terminated based on
the current sense input information.
3. The Maximum ON−time comparator compares
the actual ON−time counter value with the
maximum on−time value (t
) and
TON_MAX
immediately activates the latch (or auto−recovery)
protection mode. The minimum operating
frequency of the controller is defined the same
way. The Maximum ON−time comparator
soft−start increment number (t
)
reference is loaded by the Soft−Start counter value
on each switching cycle during soft−start. The
Maximum ON−time fault signal is ignored during
Soft−Start operation. The converter Mupper switch
on−time (and thus operating frequency) is thus
defined by the Soft−Start counter value indirectly
– via Maximum ON−time comparator. The
Mupper switch on−time is increased until the
SS_INCREMENT
during each Mlower switch on−time period. The
soft−start start increment, selectable via IC option,
thus affects the soft−start time duration. The
Mlower clock signal for the Soft−Start counter can
be divided down by the SS clock divider
(K ) in case the soft−start period
SS_INCREMENT
needs to be prolonged further – this can be also
done via IC option selection. The Soft−Start period
is terminated (i.e. the counter is loaded to its
maximum) when the FB pin voltage drops below
Soft−Start counter reaches t
period and
TON_MAX
Maximum on−time protection is activated, or until
ON−time comparator takes action and overrides
the Maximum ON−time comparator.
V
level.
FB_SKIP_IN
2. The ON−time counter is a bidirectional counter
that is used as a main system counter for on−time
modulation during soft−start, normal operation or
overload conditions. The ON−time counter
4. The Soft−Start D/A converter generates a
soft−start voltage ramp for ON−time comparator
input synchronously with Soft−Start counter
incrementing. The internal FB signal for ON−time
comparator input is artificially pulled−down and
then ramped−up gradually when soft−start period
is placed by the system – refer to Figure 51. The
FB loop is supposed to take over at certain point
counts−up during Mupper switch conduction
period and then counts down to zero – defining
Mlower switch conduction period. This technique
assures perfect 50 % duty cycle symmetry for both
www.onsemi.com
30
NCP1399 Series
when regulation loop is closed and output gets
operating frequency. The Soft−Start period is
regulated so that soft−start has no other effect on
the on−time modulation. The Soft−Start counter
continues counting−up until it reaches its
terminated (i.e. counter is loaded to its maximum)
when the FB pin voltage drops below V
level. The D/A converter output evolve
FB_SKIP_IN
maximum value which corresponds to the IC
maximum on−time value – i.e. the IC minimum
accordingly to the Soft−Start counter as it is
loaded from its output data bus.
Figure 51. Soft Start Behavior
The Controller Operation during Soft−start Sequence
Evolves as Follows:
ON−time comparator reference voltage. This reference
voltage thus also increases non−linearly from initial zero
level until the level at which the current mode regulation
starts to work. The on−time of the Mupper and Mlower
switch is then defined by the ON−time comparator action
instead of the Maximum ON−time comparator. The
soft−start then continues until the regulation loop is closed
and the on−time is fully controlled by the secondary
regulator. The Soft−Start counter then continues in counting
and saturates at its maximum possible value which
corresponds to IC minimum operating frequency. The
maximum on−time fault detection system is enabled when
The Soft−Start counter is loaded by last Mupper on−time
value at the end of the dedicated startup sequence. The
ON−time counter is released and starts count−up from zero
until the value that is equal to the actual Soft−Start counter
state. The Mupper switch is active during the time when
ON−time counter counts−up. The Maximum ON−time
comparator then changes counting mode of the ON−time
comparator from count−up to count−down. A dead−time is
placed and the Mlower switch is activated till the ON−time
counter reaches zero value. The Soft−Start counter is
incremented by selected increment during corresponding
Mlower on−time period so that the following Mupper switch
on−time is prolonged automatically – the frequency thus
drops naturally. Because the operating frequency of the
controller drops and Mlower DRV signal is used as a clock
source for the Soft−start counter, the soft−start speed starts
to decrease on each (or on each N−th) Mlower driver pulse
Soft−Start counter value is equal to t
value.
TON_MAX
The previous on−time repetition feature, described above
in the ON−time modulation and feedback loop chapter, is
disabled in the beginning of soft start period. This is because
the ON−time comparator output stays high for several cycles
of soft start period – until the current mode regulation takes
over. The previous on−time repetition feature is enabled
once the current modulation starts to work fully, i.e. in the
time when the ON−time comparator output periodically
drops to low state within actual Mupper switch on−time
period. Typical startup waveform of the LLC application
driven by NCP1399 controller can be seen in Figure 52.
(where N is defined by K ) of switching cycle.
SS_INCREMENT
So we have non−linear soft−start that helps to speed up
output charging in the beginning of the soft−start operation
and reduces the output voltage slope when the output is close
to the regulation level. The output bus of the Soft−Start
counter addresses the D/A converter that defines the
www.onsemi.com
31
NCP1399 Series
major primary current component during light load
conditions, circulates in the resonant tank and creates power
losses in the power switches despite minimum energy
transfer to the secondary side. This is why the majority of
resonant converter controllers implement skip mode
operation under light load conditions.
The NCP1399 controller implements a proprietary skip
mode technique that assures maximum light−load efficiency
and low acoustic noise. The FB pin voltage level below
which the application enters skip mode operation is fully
user adjustable for the NCP1399A device family − via
SKIP/REM adjust pin or via IC option for the NCP1399B
device family. The skip mode operation can be initiated by
the skip comparator only during actual Mupper driver
on−time period. This technique assures defined and
synchronous transition from normal to skip mode operation.
The SKIP/REM pin voltage (NCP1399Ay) or internal
voltage level (NCP1399By) defines the FB pin voltage
threshold under which is the skip mode initiated – the
maximum operating frequency of the converter is thus
defined indirectly.
The Mlower switch is always activated for a defined
on−time period at the beginning of each skip burst to
re−charge the bootstrap capacitor and thus assure enough
charge for high side driver powering during the following
Mupper pulse. The resonant capacitor average voltage level
is maintained below Vbulk/2 level during the skip mode
operation. This technique helps to minimize power loses
during the initial Mlower MOSFET switch activation – refer
to Figure 53.
Figure 52. Application Startup with NCP1399 −
Primary Current − green, Vout − magenta
Skip Mode Operation
An LLC resonant converter efficiency reaches high values
under medium and full load conditions thanks to ZVS
operation for the primary MOSFETs and ZCS operation for
the secondary rectifiers. The light−load and no−load
efficiency however drops unacceptably when a normal
frequency modulation control technique is used. This is
because the converter operating frequency needs to be
increased quite a lot compared to nominal load operating
frequency in order to maintain regulation under light load
conditions. High operating frequency increases driving
losses in the controller and also losses in the converter power
stage. Moreover, the magnetizing current that becomes
Figure 53. The average voltage of resonant capacitor is maintained below Vbulk/2 during the skip mode operation
to reduce turn−on losses during 1st Mlower skip burst pulse
The first pulse in the skip burst is always non−ZVS
because there is no magnetizing energy in the resonant tank
that could prepare ZVS condition for lower MOSFET
switch turn−on. The reduced resonant capacitor voltage thus
helps to decrease C*V^2 losses related to the total HB line
capacitance (composed from output capacitances of the
power stage MOSFETs and stray capacitance seen by the
HB line). However, too low of a resonant capacitor voltage,
The reduced resonant capacitor average voltage
requirement imposes a specific turn−off sequence to be used
at the end of each skip burst and also during transition from
normal operation mode to skip mode– refer to Figure 54.
The Mlower driver is always activated the latest during
transition to skip mode. However, the latest Mlower driver
activation on−time is equal to 3/2 of previous Mupper pulse
width when the skip mode is entered. This technique
naturally imbalances the resonant tank so that the average
resonant capacitor voltage stays below Vbulk/2 level. – i.e.
application is prepared for optimal initialization of the
following skip burst.
st
during 1 Mlower driver pulse initiation, would result in a
too low resonant tank current at the end of the first Mlower
switch conduction period and thus a non ZVS condition for
the following Mupper switch turn−on process. This is why
a full discharge of resonant capacitor is not needed before
skip mode.
www.onsemi.com
32
NCP1399 Series
Figure 54. Drivers turn−off sequence during transition to skip−mode from normal operation mode
The voltage level across the resonant capacitor after the
transition to skip mode depends on several factors:
• Actual previous Mupper switch on−time − i.e. actual
operating frequency when skip mode comparator
provides skip mode operation request to the internal
logic via its output
device family) and fixed hysteresis (V
skip out level is thus given by
). The
FB_SKIP_HYST
V
+
FB_SKIP_IN
V
value – refer to Figure 55. The controller
FB_SKIP_HYST
disables drivers and enters a low consumption mode once
the FB voltage drops below V threshold. The IC
FB_SKIP_IN
operation is restarted once the
V
+
FB_SKIP_IN
V
level is exceeded on the FB pin. As
FB_SKIP_HYST
• Resonant tank components used in the application
aforementioned, the controller then activates Mlower driver
first for a predefined time (t ) to re−charge
• Actual current flowing through the resonant tank when
1st_MLOWER_SKIP
last Mlower driver pulse is initiated
the bootstrap capacitor. The first Mupper driver pulse is then
placed by the controller after DT period elapsed. The
on−time of the first Mupper pulse is dictated by the ON−time
comparator – i.e. the on−time depends on the actual FB pin
voltage and CS pin input signal. The internal FB signal is
It should be noted that the oscilloscope probe discharges the
resonant capacitor by its resistance when connected to the
HB pin! The probe discharge effect to the resonant capacitor
is obvious when no−load is applied to the converter output
and the application enters deep skip mode. This has to be
taken into account when probing HB pin and operating
application in skip mode.
artificially reduced by V
via the ramp
1st_MUPPER_SKIP
compensation block during this first Mupper driver pulse.
This method helps reduce the primary current peak and
acoustic noise during return from skip mode. The amount of
internal FB signal and thus primary peak current
compression is adjustable via IC option.
The NCP1399 detects skip mode operation via FB voltage
level. The skip comparator features an adjustable
V
threshold (externally with the NCP1399A
FB_SKIP_IN
device family or internally by IC option with the NCP1399B
www.onsemi.com
33
NCP1399 Series
Figure 55. NCP1399 Light−load Operating Modes versus Feedback Pin Voltage
Detail Description of the Skip Mode Operation:
b2) the second Mlower pulse with on−time longer
than previous Mupper driver pulse period is placed in
case that the ON−time comparator output is high in
the end of regular Mlower period. The second
Mlower pulse is prolonged in such case until the
ON−time comparator output gets low. This technique
ensures that the current mode operation is not lost due
to resonant capacitor voltage imbalance that naturally
occurs during burst operation. The application works
with asymmetrical duty cycle in this case.
During operation under certain load conditions in normal
PFM mode (driving the resonant tank with 50% DC
symmetry), if the load drops, then the load current is reduced
and the converter operation evolves as follows:
1. The FB voltage falls below the V
FB_SKIP_IN
threshold. This event can be detected by the system
only during the Mupper switch on−time execution.
The actual Mupper pulse on−time is stored into the
dedicated t_Mu_on−time register. The last Mlower
pulse with t_Ml_on−time = 3/2* t_Mu_on−time is
introduced by the system to finish operation and
will keep the resonant capacitor out of balance at a
voltage below 1/2 of Vbulk. The controller then
enters a low consumption mode in which all
3. The dead time is placed by the system again and
situation from point b) repeats. The b2) case
repeats in a given skip burst pulse until the duty
cycle symmetry of 50% is reached i.e. until the b1)
case is reached by the system. The asymmetrical
operation is then disabled until the new
unnecessary blocks are turned off to reduce power
consumption and the IC will waits as long as the
V
threshold crossing event, i.e. until the
FB_SKIP_IN
feedback pin voltage stays above V
+
application enters skip mode again.
FB_SKIP_IN
V
level.
4. Application continues with given skip burst until
FB_SKIP_HYST
2. The FB pin voltage rises above V
+
the V
threshold is reached on the FB
FB_SKIP_IN
FB_SKIP_IN
V
threshold. The first Mlower period
pin. This situation is monitored during each
Mupper driver period. The dead time is then
placed by the driver followed by last Mlower
driver pulse with on−time equal to 3/2 of previous
Mupper driver period. The controller consumption
is then minimized by turning−off all the blocks
that are not needed. The skip comparator is
FB_SKIP_HYST
with pre−defined on−time width
(t ) is placed in order to recharge
1st_MLOWER_SKIP
the bootstrap capacitor. The first Mupper pulse is
then initiated after a dead−time period that lasts
until termination by the CS comparator. The
dead−time period is then followed by second
Mlower pulse which on−time period could differ
based on the actual application conditions:
b1) the second Mlower pulse with on−time equal to
previous Mupper driver pulse period is placed in
case that the ON−time comparator output is low
before end of regular Mlower period.
monitoring FB pin voltage – waiting for new skip
burst initialization.
Example of imbalanced operation during the skip mode
burst beginning can be seen in Figure 56. One can see that
the ON−time comparator output (Yelow) is high while
Mlower on−time is equal to the previous Mupper pulse
width – thus the Mlower on−time period is prolonged until
the ON−time comparator output drops.
www.onsemi.com
34
NCP1399 Series
Figure 56. The on−time comparator prolongs Mlower periods in case it output is high after previous Mupper
period is already exceeded on Mlower so imbalanced operation is placed by the system in order to keep current
mode operation working. This functionality is active until the duty cycle symmetry reaches 50%.
Fast transition to skip mode can occur when the load
current diminishes abruptly and the application is working
in full load. The frequency then quickly increases which can
result in resonant capacitor imbalance that could lead to a
loss of current mode operation – refer to Figure 57 for
illustration. This is why the NCP1399 repeats previous
Mupper on−time period in case the ON−time comparator
output does not drop low within this time period (i.e. within
the time equal to last Mupper on−time).
Figure 57. Mupper on−time repetition in case of transient loading when resonant capacitor imbalance occurs and
on−time comparator output stays high for several periods.
Summary of the NCP1399 Skip Mode System Operation:
When the load slowly diminishes and the operating
frequency of the LLC converter increases, skip mode with
wide skip bursts is naturally placed by the system first − refer
to Figure 58. The off−time between skip bursts increases and
the number of pulses in skip burst drops when load is
reducing further i.e. FB voltage starts to trigger the
V
+ V
thresholds with lower
FB_SKIP_IN
FB_SKIP_HYST
frequency. The single pulse burst operation could be reached
under no load on the output in systems with very fast
feedback loop response. The skip burst composes only from
single Mupper and two Mlower pulses in such case. The
initial Mlower pulse width of skip burst is defined by device
option and is used for bootstrap capacitor pre−charge and
www.onsemi.com
35
NCP1399 Series
ZVS condition preparation for following Mupper switch
1. FB voltage skip in threshold adjust
2. FB voltage skip hysteresis
3. First Mlower DRV pulse width when IC is
returning from skip mode
4. First Mupper pulse internal FB voltage reduction
factor when IC is returning from skip mode
5. Actual bulk voltage value
activation. The skip burst is always finished by the Mlower
driver pulse with period prolonged to 3/2 of previous
Mupper switch on time period in order to reduce resonant
capacitor voltage and prepare system for another skip burst
initialization.
The overall skip mode operation of the application is
affected by several factors:
Figure 58. NCP1399 Operation when Load Current Drops Down to No−load Conditions
The High Voltage Half−bridge Driver
The driver features a traditional bootstrap circuitry,
requiring an external high voltage diode with resistor in
series for the capacitor refueling path. Minimum series
resistor Rboot value is 3.3 W. Figure 59 shows the internal
architecture of the drivers section. The device incorporates
an upper UVLO circuitry that makes sure enough V is
GS
available for the upper side MOSFET.
HV
Vboot
Pulse
Trigger
Internal Mupper
Level
Shifter
S
R
Cboot
Mupper
HB
Q
Q
dV/dt_P signal
dV/dt_N signal
dV/dt
detector
UVLO
Rboot
HB
discharger
HB disch. activation
Dboot
Vcc
Mlower
GND
aux
Vcc
Fault
Internal Mlower
Delay
Figure 59. The NCP1399 Internal DRVs Structure
The internal dV/dt sensor, connected to the VBOOT pin,
detects the HB pin voltage transitions in order to setup the
optimum DT period – please refer to Dead−Time chapter.
The internal HV discharge switch is connected to the HB pin
and discharges resonant capacitor before application
startup. The current through the switch is regulated to
As stated in the maximum ratings section, the floating
portion can go up to 620 VDC on the BOOT pin. This
voltage range makes the IC perfectly suitable for offline
applications featuring a 400 V PFC front stage.
Automatic Dead−time Adjust
The dead−time period between the Mupper and Mlower
drivers is always needed in half bridge topologies to prevent
any cross conduction through the power stage MOSFETs
that would result in excessive current, high EMI noise
I
level until the V
threshold voltage is
DISCHARGE
HB_MIN
reached on the HB pin. The discharge system assures always
the same startup conditions for application – regardless of
previous operating state.
www.onsemi.com
36
NCP1399 Series
generation or total destruction of the application. Fixed
other protections would prevent such a situation. The
NCP1399 implements maximum DT period clamp that
dead−time period is often used in the resonant converters
because this approach is simple to implement. However, this
method does not ensure optimum operating conditions in
resonant topologies because the magnetizing current is
changing with line and load conditions. The optimum
dead−time, under a given operating conditions, is equal to
the time that is needed for bridge voltage to transition
between upper and lower states and vice versa – refer to
Figure 60.
limits driver’s off−time period to the t
DEAD_TIME_MAX
value. The corresponding MOSFET driver is forced to
turn−on by the internal logic regardless of missing dV/dt
sensor signal. This situation does not occur during normal
operation and will be considered a fault state by the device.
There are several possibilities on how the controller
continues operation after this event occurrence – depending
on the IC option:
1. The opposite MOSFET switch is forced to turn−on
when t
period elapses and no
DEAD_TIME_MAX
fault is generated
2. The controller is latched−off in case the ZSV
condition is not detected within selected
t
period
DEAD_TIME_MAX
3. The controller stops operation and restarts
operation after auto−recovery period in case the
ZSV condition has not been detected within the
selected t
period
DEAD_TIME_MAX
A DT fault counter option is available. Selected number
(N ) or DT fault events have to occur in order to
DT_MAX
confirm DT fault in this case.
A fixed DT option is also available for this device. The
internal dV/dt sensor signal is not used for this device option
and the t
period is used as a regular DT
DEAD_TIME_MAX
period instead. The DT fault detection is disabled in this
case.
Figure 60. Optimum Dead−time Period Adjust
Temperature Shutdown
The NCP1399 includes
protection at 150°C. The typical TSD hysteresis is 30°C.
When the temperature rises above the upper threshold, the
controller stops switching instantaneously, and goes into the
The MOSFET body diode conduction time is minimized
when optimum dead−time period is used which results in
maximum efficiency of a resonant converter power stage.
There are several methods to determine the optimum
dead−time period or to approximate it (for example using
auxiliary winding on main transformer or modulating
dead−time period with operating frequency of the
converter). These approaches however require a dedicated
pin for nominal dead−time adjust or auxiliary winding
voltage sensing. The NCP1399 uses a dedicated method that
senses the VBOOT pin voltage internally and adjusts the
optimum dead−time period with respect to the actual
operating conditions of the converter. The high−voltage
dV/dt detector, connected to the VBOOT pin, delivers two
internal digital signals that are indicating Mupper to Mlower
and Mlower to Mupper transitions that occur on the HB and
VBOOT pins after the corresponding MOSFET switch is
turned−off. The controller enables the opposite MOSFET in
the power stage once the corresponding dV/dt sensor output
provides information about HB (or VBOOT) pin transition
ends.
a temperature shutdown
off−mode with extremely low power consumption. The V
CC
supply is maintained (by operating the HV start−up in DSS
mode) in order to memorize the TSD event information.
When the temperature falls below the lower threshold, the
full restart (including soft−start) is initiated by the controller.
The HV startup current source features an independent
over−temperature protection which limits its output current
in case the DIE temperature exceeds 150°C to avoid damage
to the HV startup silicon structure.
APPLICATION INFORMATION
Controller Operation Sequencing of NCP1399xy LLC
Controller
The paragraphs below describe controller operation
sequencing under several typical cases as well as transitions
between them. The NCP1399By version is used in the
description of most operation sequences (except last
paragraph, Figure 65 that describe NCP1399Ay version).
The main behavior of NCP1399Ay is as same as
NCP1399By version except for the off−mode behavior
(REM pin function).
The ZVS transition on the bridge pin (HB) could take a
longer time or even does not finish in some cases – for
example with extremely low bulk voltage or when some
critical failure occurs. This situation should not occur
normally in correctly designed application because several
www.onsemi.com
37
NCP1399 Series
1. Application start, Brown−out off and restart,
OVP/OTP latch and then restart – Figure 61
to hold the latch−up state memorized while the application
remains plugged−in to the mains.
Application is connected to the mains at point A thus the
HV input of the controller becomes biased. The HV startup
The power supply is removed from the mains at point H
and the VCC voltage drops down below V
level
CC_RESET
current source starts charged VCC capacitor until V
CC
thus the low voltage controller is released from latch. A new
application start occurs when the user plugs the application
the mains again.
reaches V
threshold.
CC_ON
The VCC pin voltage reached V
threshold in point
CC_ON
B. The BO, FB, OVP/OTP and PFC MODE blocks are
2. Application start, Brown−out off and restart, output
short fault with auto−recovery restart – Figure 62
Operating waveforms descriptions for this figure is
similar to one for Figure 61 from point A till point G – with
enabled. The REM input is internally pulled down for
tREM_TIMER to assure that the secondary side will have enough
time to recover normal operation and pulls down the remote
optocoupler after the LLC stage restart. The VBULK/PFC
FB pin starts to receive divided bulk voltage as the external
HV switch is activated by PFC MODE output. The REM
one difference. The skip mode operation (FB
<
V
) blocks the IC startup after first V event
FB_SKIP_IN
CC_ON
instead of BO_fault.
timer is activated during each V
event except during
CC_ON
The LLC converter operation is stopped in point G
because the controller detects an overload condition (short
circuit event in this case as the Vout drops abruptly). The
controller disables all blocks except for the FB block and the
fault logic. The HV startup DSS operation is initiated in
order to keep enough VCC level for all internal blocks that
need to be biased. Internal auto−recovery timer counts down
the off−mode operation. The V blank is also activated
CC
during each V
event to ensure that the internal logic
CC_ON
ignores all fault inputs until the internal blocks are fully
biased and stabilized after a V event. The IC DRVs
CC_ON
were not enabled after first V blank period in this case as
CC
the voltage on VBULK/PFC FB is below V level. The IC
BO
keeps all internal blocks biased and operates in the DSS
(Dynamic Self−Supply) mode as long as the fault conditions
is still present.
the recovery delay period t
.
A−REC_TIMER
The auto−recovery restart delay period lapses at point H.
The HV startup current source is activated to recharge VCC
capacitor before a new restart.
The BO_OK condition is received (voltage on
VBULK/PFC FB reach V level) at point C. The IC
BO
The V
threshold is reached in point I and all the
CC_ON
activates the startup current source to refill VCC capacitor
in order to assure sufficient energy for a new startup. The
internal blocks are biased. The V blank, REM timer and
CC
OVP/OTP blank period are started at the same time. The
LLC converter operation is enabled, including a dedicated
startup and soft−start period. The output short circuit is
removed in between thus the Vout ramped−up and the FB
loop took over during the LLC converter soft−start period.
VCC capacitor voltage reaches V
level again and the
CC_ON
VCC blank period is started. The REM timer is activated
again on this V event as well. The DRVs are enabled
CC_ON
and the application is started after V blank period lapses
because there is no faults condition at that time.
CC
Line and also bulk voltage drops at point D so the BO_OK
signal become low (voltage on VBULK/PFC FB drops
3. Startup, skip−mode operation, low line detection
and restart into skip−mode – Figure 63
The application is plugged into the mains at point A thus
the HV input of the controller becomes biased. The HV
startup current source starts charging the VCC capacitor
below V level). The LLC DRVs are disabled as well as
BO
OVP/OTP block bias. The PFC MODE output stay high to
keep the bulk voltage divider connected, so the BO block
still monitors the bulk voltage. The controller activates the
HV startup current source into DSS mode to keep enough
VCC voltage for operation of all blocks that are active while
the IC is waiting for BO_OK condition.
until V reaches the V
threshold.
CC
CC_ON
The VCC pin voltage reaches the V
threshold at
CC_ON
point B. The BO, FB, OVP/OTP and PFC MODE blocks are
enabled. The REM input is pulled down for t to
REM_TIMER
The line voltage and thus also bulk voltage increase at
point E so the Brown−out block provide the BO_OK signal
assure that the secondary side will have enough time to
recover to normal operation and pulls down the remote
optocoupler after the LLC stage restarts. The VBULK/PFC
FB pin begins to receive divided bulk voltage as the external
once the V level is reached. The startup current source is
BO
activated after BO_OK signal is received to charge the VCC
capacitor for a new restart.
HV switch is activated by the PFC MODE output. The V
CC
The V
level is reached in point F. The OVP/OTP
CC_ON
blank period is activated during each V
events. This
CC_ON
block is biased, REM timer and the VCC blank period is
started at the same time. The controller restores operation
via the regular startup sequence and soft−start after VCC
blank period lapses since there is no fault condition detected.
The application then operates normally until the
OVP/OTP input is pulled−up at point G. The controller then
enters latch−off mode in which all blocks are disabled except
for the feedback block. The VCC management controls the
HV startup in DSS mode in order to keep enough VCC level
blank ensures that the internal logic ignores all fault inputs
until the internal blocks are fully biased and stabilized after
V
CC_ON
event. The IC DRVs are not enabled even after V
CC
blank period ends because the OVP fault condition is
present. The OVP fault condition disappears after some time
so the HV startup current source is enabled to prepare
enough V for a new startup attempt. The new V blank,
CC
CC
OTP blank and REM timer periods are placed after the
www.onsemi.com
38
NCP1399 Series
V
event is detected. The controller authorizes DRVs
detected. The application then enters skip mode again as the
load current is low.
CC_ON
at point C as there are no faults conditions present after the
blank period lapses.
V
CC
5. Start−up, normal operation, transition to off−mode
operation and output re−charge in off−mode
(NCP1399By versions) – Figure 64
Application is connected to the mains at point A thus the
HV input of the controller become biased. The HV startup
The application is operating under certain load conditions
between points C and D. The load current is reduced thus the
FB loop reduces the primary controller FB pin voltage. The
PFC controller is disabled (via reduced voltage on the PFC
MODE pin to V
value) in point D when the FB pin
PFC_M_BO
current source starts charging the VCC capacitor until V
CC
voltage drops below set voltage level on P ON/OFF pin.
The load diminished further and the FB skip threshold is
reached in point E. The controller turns−off all the blocks
that are not essential for the controller operation during
skip−mode – i.e. all blocks except FB block and VCC
management. This technique is used to minimize the device
consumption when there are no driver pulses during
skip−mode operation. The output voltage then drops
naturally and the FB loop reflects this change into the
primary FB pin voltage that increases accordingly. The
auxiliary winding is refilling VCC capacitor during each
skip burst thus the controller is supplied from the application
during the skip mode operation.
The controller FB skip−out threshold is reached in point
F; the controller enables all blocks and LLC DRVs to refill
the output capacitor. The controller did not activate the HV
startup current source because there is enough voltage
present on the VCC pin during skip mode. The OTP blank
periods is activated at the beginning of the skip burst to mask
possible OTP faults.
reaches V
The VCC pin voltage reached V
threshold.
CC_ON
threshold at point
CC_ON
B. The BO, FB, OVP/OTP and PFC MODE blocks are
enabled. The REM input is pulled down for t to
ensure that the secondary side has enough time to recover
normal operation and pull down the remote optocoupler
after LLC stage restarts. The VBULK/PFC FB pin starts to
receive the divided bulk voltage as the external HV switch
is activated by the PFC MODE output. The V blank
period is activated during each V
ensures that the internal logic ignores all fault inputs until the
internal blocks is fully biased and stabilized after V
event.
REM_TIMER
CC
event. This blank
CC_ON
CC_ON
The IC DRVs are enabled immediately after V blank
CC
period ends as there was no fault present at that time. The
application is operating under certain load conditions
between points C and D. The load current is reduced thus the
FB loop lowers the primary controller FB pin level. The PFC
controller is disabled (via reduced voltage on the PFC
MODE pin to V
voltage drops below the set voltage level on the P ON/OFF
pin.
value) at point D when the FB pin
PFC_M_BO
Note: The VCC capacitor needs to be chosen with a value
high enough to ensure that V will not drop below the
CC
V
level during skip mode. The device would
CC_OFF
The secondary controller activates off−mode operation
thus the REM input voltage exceeds the V
otherwise restart operation via standard startup sequence in
such a case (i.e. ramp−up the V to V level first and
REM_OFF
CC
CC_ON
threshold at point E. The controller turns−off all the blocks
that are not essential for controller operation during
off−mode – i.e. all blocks including FB block and a large
portion of the VCC management. This technique is used to
minimize device consumption when there are no driver
pulses during off−mode operation. The output voltage is
then dropped naturally due to secondary controller and
resistive dividers consumption. The primary controller is
supplied from the HV startup current source that is operated
in DSS.
enable drivers afterwards) for NCP1399By version or enters
into off−mode for NCP1399Ay (refer to Figure 65).
The line voltage drops in point G, but the bulk voltage is
dropping slowly as there is nearly no consumption from the
bulk capacitor during skip mode – only some refilling bursts
are provided by the controller. The application thus
continues in skip mode operation for several skip burst
cycles.
The bulk voltage level less than V threshold is detected
BO
by the controller in point H during one of the skip burst
pulses. The controller thus disabled DRVs and enters DSS
mode of operation in which the OVP/OTP block is disabled
and the controller is waiting for BO_OK event. The PFC
The secondary controller interrupts off−mode operation
by activating a remote optocoupler and pulling down the
REM pin at point F. The controller activates HV startup
current source and recharges the VCC capacitor to prepare
MODE provides the V
voltage in this case to
PFC_M_ON
enough V voltage for new startup.
CC
allow the PFC stage to refill bulk capacitors.
The V voltage reaches V
threshold at point G
CC
CC_ON
The line voltage is increased at point I thus the controller
receives the BO_OK signal. The BO_OK signal is received
during the period in which the HV startup current source is
active and refills the VCC capacitor.
and the LLC converter starts (including soft−start)
immediately after a V blank period ends as there is no
CC
fault detected at the end of this period.
The output voltage is ramped up while the FB loop is not
This V
threshold is reached by the VCC pin at point
CC_ON
closed yet as the V
is still below regulation level. The
OUT
J. The V blank period, OVP/OTP blank and REM timer
CC
output voltage then reaches regulation level and the FB pin
voltage drops abruptly on the primary – hitting the FB
period are started at the same time. The full startup sequence
is enabled at the end of the V blank period as no fault is
CC
www.onsemi.com
39
NCP1399 Series
skip−in threshold at point H. The LLC drivers are thus
all blocks including FB block and big portion of the VCC
management. This technique is used to minimize device
consumption when there are no drive pulses during
off−mode operation. The output voltage is then dropped
naturally due to secondary controller and resistive dividers
consumption. The primary controller is supplied from the
HV startup current source that operates in DSS mode.
The secondary controller interrupts off−mode operation
by releasing the optocoupler and allowing the voltage on FB
pin to ramp−up by the internal pull−up current source at
point G. The controller activates the HV startup current
source and recharges the VCC capacitor to prepare enough
disabled by skip comparator. The FB then increased
naturally – calling for new skip burst (refer to skip mode
operation description in previous part).
Secondary controller activates the off−mode operation by
releasing the remote optocoupler while the primary
controller is operating in skip−mode. The REM pin voltage
thus increases slowly up and hit the V
threshold
REM_OFF
where the primary controller enters off−mode operation
again at point I.
6. Start−up, normal operation, transition to off−mode
operation and output re−charge in off−mode
(NCP1399Ay versions) – Figure 65
Operating waveforms descriptions for this figure are the
same as for Figure 64 from point A until point D – Please
refer to Figure 64 for details regarding operation between
these time events.
V
CC
voltage for a new startup.
The V voltage reaches V
threshold at point H
CC_ON
CC
and the LLC converter starts (including soft−start)
immediately after a V blank period ends as there is no
CC
fault detected at the end of the period.
The output voltage is ramped up while the FB loop is not
The secondary controller activates off−mode operation by
closed yet as the V
is still below regulation level. The
OUT
pulling FB pin below V
level, thus the IC goes
FB_REM_OFF
output voltage then reaches regulation level and the FB pin
voltage drops abruptly on the primary – hitting the FB
skip−in threshold at point I. The LLC drivers are thus
disabled by the skip comparator. The FB then increases
naturally – calling for new skip burst (refer to skip mode
operation description in previous text).
into skip−mode for long time at point E. The controller
turns−off all the blocks that are not essential for controller
operation during skip−mode – i.e. all blocks except FB, BO
and VCC management blocks. This technique is used to
minimize device consumption when there are no driver
pulses during skip−mode operation.
The secondary controller activates off−mode operation by
The V
drops naturally by IC consumption below
CC
pulling−down FB pin and V
voltage naturally drops
CC
V
threshold at point F – i.e. the off−mode is
CC_OFF
below V
threshold. The primary controller enters
CC_OFF
confirmed. The controller turns−off all the blocks that are
not essential for controller operation during off−mode – i.e.
off−mode operation again at point J.
www.onsemi.com
40
NCP1399 Series
Figure 61. Application Start, Brown−out Off and Restart, OVP/OTP Latch and then Restart
www.onsemi.com
41
NCP1399 Series
Figure 62. Application Start, Brown−out Off and Restart,
Output Short Fault with Auto−recovery Restart
www.onsemi.com
42
NCP1399 Series
Figure 63. Startup, Skip−mode Operation, Low Lone Detection and Restart into Skip
www.onsemi.com
43
NCP1399 Series
Figure 64. Start−up, Normal Operation, Transition to Off−mode Operation
and Output Re−charge in Off−mode – NCP1399By Version
www.onsemi.com
44
NCP1399 Series
Figure 65. Start−up, Normal Operation, Transition to Off−mode Operation
and Output Re−charge in Off−mode – NCP1399Ay Version
www.onsemi.com
45
NCP1399 Series
PACKAGE DIMENSIONS
SOIC−16 NB MISSING PINS 2 AND 13
CASE 751DU
ISSUE O
NOTE 5
NOTES:
1. DIMENSIONING AND TOLERANCING PER ASME Y14.5M, 1994.
2. CONTROLLING DIMENSION: MILLIMETERS.
D
A
2X
16
9
3. DIMENSION b DOES NOT INCLUDE DAMBAR PROTRUSION.
ALLOWABLE PROTRUSION SHALL BE 0.10 mm IN EXCESS OF
MAXIMUM MATERIAL CONDITION.
4. DIMENSIONS D AND E DO NOT INCLUDE MOLD FLASH,
PROTRUSIONS OR GATE BURRS. MOLD FLASH, PROTRUSIONS
OR GATE BURRS SHALL NOT EXCEED 0.25 mm PER SIDE.
DIMENSIONS D AND E ARE DETERMINED AT DATUM F.
5. DIMENSIONS A AND B ARE TO BE DETERMINED AT DATUM F.
6. A1 IS DEFINED AS THE VERTICAL DISTANCE FROM THE SEATING
PLANE TO THE LOWEST POINT ON THE PACKAGE BODY.
0.10 C D
F
NOTE 4
E
E1
NOTE 6
A1
L
L2
1
8
0.20 C
SEATING
PLANE
C
MILLIMETERS
B
NOTE 5
14X b
DETAIL A
2X 4 TIPS
DIM MIN
MAX
1.75
0.25
0.49
0.25
10.00
M
0.25
C A-B D
A
A1
b
1.35
0.10
0.35
0.17
9.80
TOP VIEW
2X
c
0.10 C A-B
0.10 C
DETAIL A
D
D
E
6.00 BSC
0.10 C
E1
e
3.90 BSC
1.27 BSC
L
0.40
1.27
0.203 BSC
L2
e
END VIEW
A
SEATING
C
PLANE
SIDE VIEW
RECOMMENDED
SOLDERING FOOTPRINT
14X
1.52
16
1
9
7.00
8
14X
0.60
1.27
PITCH
DIMENSIONS: MILLIMETERS
ON Semiconductor and
are trademarks of Semiconductor Components Industries, LLC dba ON Semiconductor or its subsidiaries in the United States and/or other countries.
ON Semiconductor owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of ON Semiconductor’s product/patent
coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. ON Semiconductor reserves the right to make changes without further notice to any products herein.
ON Semiconductor makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does ON Semiconductor assume any liability
arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages.
Buyer is responsible for its products and applications using ON Semiconductor products, including compliance with all laws, regulations and safety requirements or standards,
regardless of any support or applications information provided by ON Semiconductor. “Typical” parameters which may be provided in ON Semiconductor data sheets and/or
specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer
application by customer’s technical experts. ON Semiconductor does not convey any license under its patent rights nor the rights of others. ON Semiconductor products are not
designed, intended, or authorized for use as a critical component in life support systems or any FDA Class 3 medical devices or medical devices with a same or similar classification
in a foreign jurisdiction or any devices intended for implantation in the human body. Should Buyer purchase or use ON Semiconductor products for any such unintended or unauthorized
application, Buyer shall indemnify and hold ON Semiconductor and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and
expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such
claim alleges that ON Semiconductor was negligent regarding the design or manufacture of the part. ON Semiconductor is an Equal Opportunity/Affirmative Action Employer. This
literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT:
N. American Technical Support: 800−282−9855 Toll Free
USA/Canada
Europe, Middle East and Africa Technical Support:
Phone: 421 33 790 2910
Japan Customer Focus Center
Phone: 81−3−5817−1050
ON Semiconductor Website: www.onsemi.com
Order Literature: http://www.onsemi.com/orderlit
Literature Distribution Center for ON Semiconductor
19521 E. 32nd Pkwy, Aurora, Colorado 80011 USA
Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada
Fax: 303−675−2176 or 800−344−3867 Toll Free USA/Canada
Email: orderlit@onsemi.com
For additional information, please contact your local
Sales Representative
◊
NCP1399/D