HG2-AC6V-F [PANASONIC]

Power/Signal Relay, DPDT, Momentary, 4200mW (Coil), AC Input, AC Output, Socket Mount, ROHS COMPLIANT;
HG2-AC6V-F
型号: HG2-AC6V-F
厂家: PANASONIC    PANASONIC
描述:

Power/Signal Relay, DPDT, Momentary, 4200mW (Coil), AC Input, AC Output, Socket Mount, ROHS COMPLIANT

光电二极管 继电器
文件: 总5页 (文件大小:92K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
20 AMP POWER RELAY  
HG RELAYS  
TYPICAL APPLICATIONS  
HP relays enjoy wide use in various  
applications, particularly in automation  
controls and remote controls.  
9. Control of conveyance equipment  
Control panels for elevators, escalators,  
and other conveyance equipment, control  
of all kinds industrial transport equipment  
such as conveyors.  
Applications include:  
1. Industrial machinery  
For controlling positioning, pressure, and  
temperature in molding equipment,  
boilers, pumps, charging pressure  
equipment, measuring and evaluation  
equipment, textile machines, etc.  
2. Machine tools  
10. Amusement equipment  
Control of equipment in amusement  
parks, etc., control of bowling alley  
equipment, control of fountains in public  
parks  
Control of positioning and directional  
change in turning machines, lathes,  
borers, etc.  
3. Food processing packing machines  
Automatic control of packing equipment  
for milk and seafood, bottling, canning,  
and packaging  
4. Office equipment  
Control of copiers, time recorders, etc.  
5. Coin operate machines  
Control of food, cigarette, and other  
vending machines  
About Cd-free contacts  
We have introduced Cadmium free type  
products to reduce Environmental  
Hazardous Substances. (The suffix “F”  
should be added to the part number.)  
Please replace parts containing  
Cadmium with Cadmium-free products  
and evaluate them with your actual  
application before use because the life of  
a relay depends on the contact material  
and load.  
Compliance with RoHS Directive  
FEATURES  
1. High-capacity and long life  
The electrical life of this high capacity is  
20A 100,000 operations (250 V AC). It  
can be used for 1.5kW (3-phase 200 V)  
motor control.  
2. High breakdown voltage  
Both between contacts, and between  
contacts and coil, high breakdown  
voltage is 2,000 V for 1 minute.  
3. Easy mounting and wiring  
The terminal arrangement is apparent at  
a glance and wiring is easy. Moreover,  
#250 series tab terminals can be used.  
4. Socket and terminal sockets  
available  
Lineup includes DIN terminal sockets that  
enable the use of DIN rails. The pole  
numbers of the terminal sockets are  
interchangeable and different terminal  
sockets can be used in combination.  
5. UL/CSA approved  
6.Transportation  
Amplification of control signals in control  
devices for vehicles and vessels,  
functional parts of all kinds of equipment,  
control signal repeating installation in  
signaling devices and equipment.  
7. Measuring devices and equipment  
For repeating installation of control  
signals and in power amplifiers  
8. Generators, transformers and  
power receiving equipment.  
Functional parts in protective equipment,  
functional assistance in automatic  
adjustment equipment, telemeters and  
other remote monitoring equipment  
ORDERING INFORMATION  
HG  
F
Contact arrangement  
2: 2 Form C  
3: 3 Form C  
4: 4 Form C  
Coil voltage  
AC 6, 12, 24, 48, 100, (115), 200, (220), (240) V  
DC 6, 12, 24, 48, 100, (110), 200 V  
Contact material  
F: AgSnO2 type  
The voltage values in parentheses are for order-made products for export.  
Note: UL/CSA approved type is standard.  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
HG  
TYPES  
2 Form C  
3 Form C  
4 Form C  
Coil voltage  
Part No.  
Part No.  
Part No.  
6V AC  
12V AC  
24V AC  
48V AC  
100V AC  
115V AC  
200V AC  
220V AC  
240V AC  
6V DC  
HG2-AC6V-F  
HG2-AC12V-F  
HG2-AC24V-F  
HG2-AC48V-F  
HG2-AC100V-F  
HG2-AC115V-F  
HG2-AC200V-F  
HG2-AC220V-F  
HG2-AC240V-F  
HG2-DC6V-F  
HG2-DC12V-F  
HG2-DC24V-F  
HG2-DC48V-F  
HG2-DC100V-F  
HG2-DC110V-F  
HG2-DC200V-F  
HG3-AC6V-F  
HG3-AC12V-F  
HG3-AC24V-F  
HG3-AC48V-F  
HG3-AC100V-F  
HG3-AC115V-F  
HG3-AC200V-F  
HG3-AC220V-F  
HG3-AC240V-F  
HG3-DC6V-F  
HG3-DC12V-F  
HG3-DC24V-F  
HG3-DC48V-F  
HG3-DC100V-F  
HG3-DC110V-F  
HG3-DC200V-F  
HG4-AC6V-F  
HG4-AC12V-F  
HG4-AC24V-F  
HG4-AC48V-F  
HG4-AC100V-F  
HG4-AC115V-F  
HG4-AC200V-F  
HG4-AC220V-F  
HG4-AC240V-F  
HG4-DC6V-F  
HG4-DC12V-F  
HG4-DC24V-F  
HG4-DC48V-F  
HG4-DC100V-F  
HG4-DC110V-F  
HG4-DC200V-F  
12V DC  
24V DC  
48V DC  
100V DC  
110V DC  
200V DC  
Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs.  
Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs.  
Notes: 1. Terminal sockets and sockets are not included. Please order these separately.  
2. For products compliant with international standards, please refer to the standards chart.  
RATING  
1. Coil data  
1) AC coils  
Nominal operating  
current  
[ 20%] (at 20°C 68°F)  
Nominal operating  
power  
Max. allowable  
voltage  
(at 40°C 104°F)  
Coil inductance  
Contact  
arrangement  
Nominal coil  
voltage  
Pick-up voltage Drop-out voltage  
(at 20°C 68°F) (at 20°C 68°F)  
50Hz  
693mA  
347mA  
167mA  
86mA  
60Hz  
600mA  
300mA  
150mA  
75mA  
50Hz  
60Hz  
50Hz  
60Hz  
6V AC  
12V AC  
24V AC  
48V AC  
100V AC  
115V AC  
200V AC  
220V AC  
240V AC  
6V AC  
0.027H  
0.107H  
0.441H  
1.717H  
7.457H  
9.868H  
30.39H  
35.99H  
42.06H  
0.019H  
0.074H  
0.299H  
1.195H  
5.174H  
6.844H  
20.71H  
25.00H  
29.97H  
0.013H  
0.051H  
0.204H  
0.817H  
3.540H  
4.685H  
14.16H  
17.48H  
20.48H  
0.026H  
0.104H  
0.416H  
1.660H  
7.216H  
9.531H  
29.00H  
34.82H  
41.68H  
0.018H  
0.073H  
0.290H  
1.163H  
5.039H  
6.648H  
20.14H  
24.27H  
29.06H  
0.012H  
0.050H  
0.199H  
0.795H  
3.444H  
4.557H  
13.79H  
16.89H  
19.87H  
80%V or less of 30%V or more of  
110%V of  
nominal voltage  
2 Form C  
3 Form C  
4 Form C  
nominal voltage  
(Initial)  
nominal voltage  
(Initial)  
42mA  
36mA  
4.2VA  
3.6VA  
36mA  
31.3mA  
18mA  
21mA  
19mA  
16.4mA  
15mA  
18mA  
1,000mA  
504mA  
250mA  
125mA  
61mA  
864mA  
432mA  
216mA  
108mA  
52mA  
12V AC  
24V AC  
48V AC  
100V AC  
115V AC  
200V AC  
220V AC  
240V AC  
6V AC  
80%V or less of 30%V or more of  
110%V of  
nominal voltage  
nominal voltage  
(Initial)  
nominal voltage  
(Initial)  
6.0VA  
5.2VA  
52.4mA  
30mA  
45.2mA  
26mA  
27.3mA  
25mA  
23.6mA  
21.6mA  
1,264mA  
632mA  
316mA  
158mA  
76mA  
1,477mA  
733mA  
367mA  
184mA  
88mA  
12V AC  
24V AC  
48V AC  
100V AC  
115V AC  
200V AC  
220V AC  
240V AC  
80%V or less of 30%V or more of  
110%V of  
nominal voltage  
nominal voltage  
(Initial)  
nominal voltage  
(Initial)  
8.8VA  
7.6VA  
76.8mA  
44mA  
66.1mA  
38mA  
39mA  
34mA  
36.6mA  
31.6mA  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
HG  
2) DC coils  
Nominal operating  
current  
[ 10%] (at 20°C 68°F)  
Max. allowable  
voltage  
(at 40°C 104°F)  
Contact  
arrangement  
Nominal coil  
voltage  
Pick-up voltage Drop-out voltage  
(at 20°C 68°F) (at 20°C 68°F)  
Coil resistance  
[ 10%] (at 20°C 68°F)  
Nominal operating  
power  
6V DC  
12V DC  
24V DC  
48V DC  
100V DC  
110V DC  
200V DC  
6V DC  
230mA  
119.6mA  
57.6mA  
30.3mA  
14.4mA  
14.4mA  
7.2mA  
26.4Ω  
100Ω  
416Ω  
1,585Ω  
6,950Ω  
7,650Ω  
27,800Ω  
22.7Ω  
1.4W  
1.4W  
1.4W  
1.5W  
1.4W  
1.6W  
1.4W  
1.6W  
1.6W  
1.6W  
1.6W  
1.7W  
1.8W  
1.7W  
2.0W  
2.0W  
1.9W  
2.2W  
2.0W  
2.2W  
2.6W  
80%V or less of 10%V or more of  
110%V of  
nominal voltage  
2 Form C  
3 Form C  
4 Form C  
nominal voltage  
(Initial)  
nominal voltage  
(Initial)  
264mA  
134mA  
66mA  
12V DC  
24V DC  
48V DC  
100V DC  
110V DC  
200V DC  
6V DC  
89.5Ω  
364Ω  
80%V or less of 10%V or more of  
110%V of  
nominal voltage  
nominal voltage  
(Initial)  
nominal voltage  
(Initial)  
33.1mA  
16.5mA  
16.5mA  
8.4mA  
1,450Ω  
6,060Ω  
6,670Ω  
23,800Ω  
18.5Ω  
71.4Ω  
296Ω  
1,050Ω  
4,930Ω  
5,420Ω  
15,500Ω  
325mA  
168mA  
81.2mA  
45.7mA  
20.3mA  
20.3mA  
12.9mA  
12V DC  
24V DC  
48V DC  
100V DC  
110V DC  
200V DC  
80%V or less of 10%V or more of  
110%V of  
nominal voltage  
nominal voltage  
(Initial)  
nominal voltage  
(Initial)  
Notes: 1. The rated current area is 15% (60Hz) [AC coils],. 10% (20°C) [DC coils]  
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate 0.4% for every 1°C change in temperature.  
3. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the  
rated voltage. In particular, for AC operation, if the impressed voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will  
flow leading possibly to coil burnout.  
4. As a general rule, only a pure DC voltage should be used for the coil drive.  
However, a DC power supply that contains ripples has characteristics that differ from pure DC.  
Therefore, please verify characteristics (operate voltage, release voltage, humming) using the actual circuit that will be used.  
2. Specifications  
Characteristics  
Item  
Initial contact resistance, max  
Contact material  
Specifications  
Max. 15 m(By voltage drop 6 V DC 1A)  
AgSnO2 type  
Contact  
Nominal switching capacity  
Min. switching capacity (Reference value)*1  
20A 250V AC (resistive load)  
100mA 5V DC  
Rating  
Min. 100M(at 500V DC)  
Measurement at same location as “Initial breakdown voltage” section.  
Insulation resistance (Initial)  
Between open contacts  
2,000 Vrms for 1min (Detection current: 10mA.)  
Breakdown voltage  
Between contact sets  
(Initial)  
2,000 Vrms for 1min (Detection current: 10mA.)  
Electrical  
characteristics  
Between contact and coil  
2,000 Vrms for 1min (Detection current: 10mA.)  
Max. 30ms (2 Form C), Max.40ms (3 Form C, 4 Form C)  
(Nominal voltage applied to the coil, excluding contact bounce time.)  
Operate time*2  
Max. 30ms (2 Form C), Max.40ms (3 Form C, 4 Form C)  
(Nominal voltage applied to the coil, excluding contact bounce time.) (without diode)  
Release time*2  
Min. 98 m/s2 (Except for contact operating direction)  
(Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)  
Functional  
Shock resistance  
Mechanical  
characteristics  
Destructive  
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)  
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)  
10 to 55 Hz at double amplitude of 2 mm  
Min. 107 (at 180 cpm)  
Functional  
Vibration resistance  
Destructive  
AC coil  
Mechanical  
Expected life  
DC coil  
Min. 106 (at 180 cpm)  
Electrical  
20A 250V AC resistive load (cosϕ=1), Min. 105  
Ambient temperature: –50°C to +40°C –58°F to +104°F  
Conditions for operation, transport and storage*3  
Max. Operating speed  
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)  
Conditions  
Unit weight  
20 cpm (at max. rating)  
2 Form C: approx. 130g 4.59oz, 3 Form C: approx. 185g 6.53oz, 4 Form C: approx. 240g 8.47oz  
Notes: *1 This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the  
actual load.  
*2 For the AC coil types, the operate/release time will differ depending on the phase.  
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to 6. Conditions for operation,  
transport and storage mentioned in AMBIENT ENVIRONMENT .  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
HG  
REFERENCE DATA  
1. Switching capacity range  
AC resistive  
load  
20  
10  
AC inductive  
load (cosϕ=0.4)  
DC resistive  
load  
DC inductive  
1
load (L/R=7ms)  
0.1  
10  
100  
500 1,000  
Contact voltage, V  
DIMENSIONS (Unit: mm inch)  
2 Form C  
External dimensions  
Schematic (Bottom view)  
2.5 dia. 9 deep hole for  
7
2
8.4  
.331  
7
.276  
3 dia. tapping screw  
8
6
5
1
3
4
.098 dia. .354 deep hole for  
.118 dia. tapping screw  
16  
.630  
20.5  
.807  
2.5 dia. 8 deep hole for  
3 dia. tapping screw  
.098 dia. .315 deep hole for  
.118 dia. tapping screw  
15  
.591  
34  
1.339  
36  
1.417  
56  
2.205  
4
.157  
8.5  
.335  
Compatible with tab terminal  
#250 series receptacle.  
7
.276  
10.5  
.413  
7.5  
.295  
7.26  
.286  
17  
.669  
General tolerance: 0.5 .020  
3 Form C  
External dimensions  
Schematic (Bottom view)  
2.5 dia. 9 deep hole for  
3 dia. tapping screw  
.098 dia. .354 deep hole for  
.118 dia. tapping screw  
10  
2
8.4  
8.4  
7
.276  
.331 .331  
11  
9
8
1
4
5
3
6
7
16  
.630  
20.5  
.807  
2.5 dia. 8 deep hole for  
3 dia. tapping screw  
.098 dia. .315 deep hole for  
.118 dia. tapping screw  
17  
.669  
50  
1.969  
36  
1.417  
56  
2.205  
4
.157  
8.5  
.335  
Compatible with tab terminal  
#250 series receptacle.  
7
.276  
10.5  
.413  
7.5  
.295  
7.26  
.286  
17  
17  
.669 .669  
General tolerance: 0.5 .020  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
HG  
4 Form C  
External dimensions  
Schematic (Bottom view)  
2.5 dia. 9 deep hole for  
10  
1
8.4  
.331  
8.4  
.331  
7
.276  
3 dia. tapping screw  
9
8
7
2
3
4
.098 dia. .354 deep hole for  
.118 dia. tapping screw  
15 11  
14 12  
6 5  
16  
.630  
20.5  
.807  
2.5 dia. 8 deep hole for  
3 dia. tapping screw  
.098 dia. .315 deep hole for  
.118 dia. tapping screw  
34  
1.339  
68  
2.677  
36  
1.417  
56  
2.205  
4
.157  
8.5  
.335  
Compatible with tab terminal  
#250 series receptacle.  
7
.276  
10.5  
.413  
7.5  
.295  
7.26  
.286  
17  
17  
17  
.669 .669 .669  
General tolerance: 0.5 .020  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  

相关型号:

HG2-DC100V-F

TYPICAL APPLICATIONS
PANASONIC

HG2-DC110V

Power/Signal Relay, DPDT, Momentary, 0.014A (Coil), 110VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount,
PANASONIC

HG2-DC110V-F

TYPICAL APPLICATIONS
PANASONIC

HG2-DC12V

Power/Signal Relay, DPDT, Momentary, 0.12A (Coil), 12VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount,
PANASONIC

HG2-DC12V-F

TYPICAL APPLICATIONS
PANASONIC

HG2-DC200V

Power/Signal Relay, DPDT, Momentary, 0.007A (Coil), 200VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount,
PANASONIC

HG2-DC200V-F

TYPICAL APPLICATIONS
PANASONIC

HG2-DC24V

20 AMP POWER RELAY
PANASONIC

HG2-DC24V-F

TYPICAL APPLICATIONS
PANASONIC

HG2-DC48V

Power/Signal Relay, DPDT, Momentary, 0.03A (Coil), 48VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount,
PANASONIC

HG2-DC48V-F

TYPICAL APPLICATIONS
PANASONIC

HG2-DC6V

Power/Signal Relay, DPDT, Momentary, 0.23A (Coil), 6VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount
PANASONIC