HG2-AC6V-F [PANASONIC]
Power/Signal Relay, DPDT, Momentary, 4200mW (Coil), AC Input, AC Output, Socket Mount, ROHS COMPLIANT;型号: | HG2-AC6V-F |
厂家: | PANASONIC |
描述: | Power/Signal Relay, DPDT, Momentary, 4200mW (Coil), AC Input, AC Output, Socket Mount, ROHS COMPLIANT 光电二极管 继电器 |
文件: | 总5页 (文件大小:92K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
20 AMP POWER RELAY
HG RELAYS
TYPICAL APPLICATIONS
HP relays enjoy wide use in various
applications, particularly in automation
controls and remote controls.
9. Control of conveyance equipment
Control panels for elevators, escalators,
and other conveyance equipment, control
of all kinds industrial transport equipment
such as conveyors.
Applications include:
1. Industrial machinery
For controlling positioning, pressure, and
temperature in molding equipment,
boilers, pumps, charging pressure
equipment, measuring and evaluation
equipment, textile machines, etc.
2. Machine tools
10. Amusement equipment
Control of equipment in amusement
parks, etc., control of bowling alley
equipment, control of fountains in public
parks
Control of positioning and directional
change in turning machines, lathes,
borers, etc.
3. Food processing packing machines
Automatic control of packing equipment
for milk and seafood, bottling, canning,
and packaging
4. Office equipment
Control of copiers, time recorders, etc.
5. Coin operate machines
Control of food, cigarette, and other
vending machines
About Cd-free contacts
We have introduced Cadmium free type
products to reduce Environmental
Hazardous Substances. (The suffix “F”
should be added to the part number.)
Please replace parts containing
Cadmium with Cadmium-free products
and evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
Compliance with RoHS Directive
FEATURES
1. High-capacity and long life
The electrical life of this high capacity is
20A 100,000 operations (250 V AC). It
can be used for 1.5kW (3-phase 200 V)
motor control.
2. High breakdown voltage
Both between contacts, and between
contacts and coil, high breakdown
voltage is 2,000 V for 1 minute.
3. Easy mounting and wiring
The terminal arrangement is apparent at
a glance and wiring is easy. Moreover,
#250 series tab terminals can be used.
4. Socket and terminal sockets
available
Lineup includes DIN terminal sockets that
enable the use of DIN rails. The pole
numbers of the terminal sockets are
interchangeable and different terminal
sockets can be used in combination.
5. UL/CSA approved
6.Transportation
Amplification of control signals in control
devices for vehicles and vessels,
functional parts of all kinds of equipment,
control signal repeating installation in
signaling devices and equipment.
7. Measuring devices and equipment
For repeating installation of control
signals and in power amplifiers
8. Generators, transformers and
power receiving equipment.
Functional parts in protective equipment,
functional assistance in automatic
adjustment equipment, telemeters and
other remote monitoring equipment
ORDERING INFORMATION
HG
F
Contact arrangement
2: 2 Form C
3: 3 Form C
4: 4 Form C
Coil voltage
AC 6, 12, 24, 48, 100, (115), 200, (220), (240) V
DC 6, 12, 24, 48, 100, (110), 200 V
Contact material
F: AgSnO2 type
The voltage values in parentheses are for order-made products for export.
Note: UL/CSA approved type is standard.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HG
TYPES
2 Form C
3 Form C
4 Form C
Coil voltage
Part No.
Part No.
Part No.
6V AC
12V AC
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
6V DC
HG2-AC6V-F
HG2-AC12V-F
HG2-AC24V-F
HG2-AC48V-F
HG2-AC100V-F
HG2-AC115V-F
HG2-AC200V-F
HG2-AC220V-F
HG2-AC240V-F
HG2-DC6V-F
HG2-DC12V-F
HG2-DC24V-F
HG2-DC48V-F
HG2-DC100V-F
HG2-DC110V-F
HG2-DC200V-F
HG3-AC6V-F
HG3-AC12V-F
HG3-AC24V-F
HG3-AC48V-F
HG3-AC100V-F
HG3-AC115V-F
HG3-AC200V-F
HG3-AC220V-F
HG3-AC240V-F
HG3-DC6V-F
HG3-DC12V-F
HG3-DC24V-F
HG3-DC48V-F
HG3-DC100V-F
HG3-DC110V-F
HG3-DC200V-F
HG4-AC6V-F
HG4-AC12V-F
HG4-AC24V-F
HG4-AC48V-F
HG4-AC100V-F
HG4-AC115V-F
HG4-AC200V-F
HG4-AC220V-F
HG4-AC240V-F
HG4-DC6V-F
HG4-DC12V-F
HG4-DC24V-F
HG4-DC48V-F
HG4-DC100V-F
HG4-DC110V-F
HG4-DC200V-F
12V DC
24V DC
48V DC
100V DC
110V DC
200V DC
Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs.
Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs.
Notes: 1. Terminal sockets and sockets are not included. Please order these separately.
2. For products compliant with international standards, please refer to the standards chart.
RATING
1. Coil data
1) AC coils
Nominal operating
current
[ 20%] (at 20°C 68°F)
Nominal operating
power
Max. allowable
voltage
(at 40°C 104°F)
Coil inductance
Contact
arrangement
Nominal coil
voltage
Pick-up voltage Drop-out voltage
(at 20°C 68°F) (at 20°C 68°F)
50Hz
693mA
347mA
167mA
86mA
60Hz
600mA
300mA
150mA
75mA
50Hz
60Hz
50Hz
60Hz
6V AC
12V AC
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
6V AC
0.027H
0.107H
0.441H
1.717H
7.457H
9.868H
30.39H
35.99H
42.06H
0.019H
0.074H
0.299H
1.195H
5.174H
6.844H
20.71H
25.00H
29.97H
0.013H
0.051H
0.204H
0.817H
3.540H
4.685H
14.16H
17.48H
20.48H
0.026H
0.104H
0.416H
1.660H
7.216H
9.531H
29.00H
34.82H
41.68H
0.018H
0.073H
0.290H
1.163H
5.039H
6.648H
20.14H
24.27H
29.06H
0.012H
0.050H
0.199H
0.795H
3.444H
4.557H
13.79H
16.89H
19.87H
80%V or less of 30%V or more of
110%V of
nominal voltage
2 Form C
3 Form C
4 Form C
nominal voltage
(Initial)
nominal voltage
(Initial)
42mA
36mA
4.2VA
3.6VA
36mA
31.3mA
18mA
21mA
19mA
16.4mA
15mA
18mA
1,000mA
504mA
250mA
125mA
61mA
864mA
432mA
216mA
108mA
52mA
12V AC
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
6V AC
80%V or less of 30%V or more of
110%V of
nominal voltage
nominal voltage
(Initial)
nominal voltage
(Initial)
6.0VA
5.2VA
52.4mA
30mA
45.2mA
26mA
27.3mA
25mA
23.6mA
21.6mA
1,264mA
632mA
316mA
158mA
76mA
1,477mA
733mA
367mA
184mA
88mA
12V AC
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
80%V or less of 30%V or more of
110%V of
nominal voltage
nominal voltage
(Initial)
nominal voltage
(Initial)
8.8VA
7.6VA
76.8mA
44mA
66.1mA
38mA
39mA
34mA
36.6mA
31.6mA
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HG
2) DC coils
Nominal operating
current
[ 10%] (at 20°C 68°F)
Max. allowable
voltage
(at 40°C 104°F)
Contact
arrangement
Nominal coil
voltage
Pick-up voltage Drop-out voltage
(at 20°C 68°F) (at 20°C 68°F)
Coil resistance
[ 10%] (at 20°C 68°F)
Nominal operating
power
6V DC
12V DC
24V DC
48V DC
100V DC
110V DC
200V DC
6V DC
230mA
119.6mA
57.6mA
30.3mA
14.4mA
14.4mA
7.2mA
26.4Ω
100Ω
416Ω
1,585Ω
6,950Ω
7,650Ω
27,800Ω
22.7Ω
1.4W
1.4W
1.4W
1.5W
1.4W
1.6W
1.4W
1.6W
1.6W
1.6W
1.6W
1.7W
1.8W
1.7W
2.0W
2.0W
1.9W
2.2W
2.0W
2.2W
2.6W
80%V or less of 10%V or more of
110%V of
nominal voltage
2 Form C
3 Form C
4 Form C
nominal voltage
(Initial)
nominal voltage
(Initial)
264mA
134mA
66mA
12V DC
24V DC
48V DC
100V DC
110V DC
200V DC
6V DC
89.5Ω
364Ω
80%V or less of 10%V or more of
110%V of
nominal voltage
nominal voltage
(Initial)
nominal voltage
(Initial)
33.1mA
16.5mA
16.5mA
8.4mA
1,450Ω
6,060Ω
6,670Ω
23,800Ω
18.5Ω
71.4Ω
296Ω
1,050Ω
4,930Ω
5,420Ω
15,500Ω
325mA
168mA
81.2mA
45.7mA
20.3mA
20.3mA
12.9mA
12V DC
24V DC
48V DC
100V DC
110V DC
200V DC
80%V or less of 10%V or more of
110%V of
nominal voltage
nominal voltage
(Initial)
nominal voltage
(Initial)
Notes: 1. The rated current area is 15% (60Hz) [AC coils],. 10% (20°C) [DC coils]
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate 0.4% for every 1°C change in temperature.
3. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage. In particular, for AC operation, if the impressed voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will
flow leading possibly to coil burnout.
4. As a general rule, only a pure DC voltage should be used for the coil drive.
However, a DC power supply that contains ripples has characteristics that differ from pure DC.
Therefore, please verify characteristics (operate voltage, release voltage, humming) using the actual circuit that will be used.
2. Specifications
Characteristics
Item
Initial contact resistance, max
Contact material
Specifications
Max. 15 mΩ (By voltage drop 6 V DC 1A)
AgSnO2 type
Contact
Nominal switching capacity
Min. switching capacity (Reference value)*1
20A 250V AC (resistive load)
100mA 5V DC
Rating
Min. 100MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Insulation resistance (Initial)
Between open contacts
2,000 Vrms for 1min (Detection current: 10mA.)
Breakdown voltage
Between contact sets
(Initial)
2,000 Vrms for 1min (Detection current: 10mA.)
Electrical
characteristics
Between contact and coil
2,000 Vrms for 1min (Detection current: 10mA.)
Max. 30ms (2 Form C), Max.40ms (3 Form C, 4 Form C)
(Nominal voltage applied to the coil, excluding contact bounce time.)
Operate time*2
Max. 30ms (2 Form C), Max.40ms (3 Form C, 4 Form C)
(Nominal voltage applied to the coil, excluding contact bounce time.) (without diode)
Release time*2
Min. 98 m/s2 (Except for contact operating direction)
(Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Functional
Shock resistance
Mechanical
characteristics
Destructive
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 2 mm
Min. 107 (at 180 cpm)
Functional
Vibration resistance
Destructive
AC coil
Mechanical
Expected life
DC coil
Min. 106 (at 180 cpm)
Electrical
20A 250V AC resistive load (cosϕ=1), Min. 105
Ambient temperature: –50°C to +40°C –58°F to +104°F
Conditions for operation, transport and storage*3
Max. Operating speed
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions
Unit weight
20 cpm (at max. rating)
2 Form C: approx. 130g 4.59oz, 3 Form C: approx. 185g 6.53oz, 4 Form C: approx. 240g 8.47oz
Notes: *1 This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 For the AC coil types, the operate/release time will differ depending on the phase.
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to 6. Conditions for operation,
transport and storage mentioned in AMBIENT ENVIRONMENT .
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HG
REFERENCE DATA
1. Switching capacity range
AC resistive
load
20
10
AC inductive
load (cosϕ=0.4)
DC resistive
load
DC inductive
1
load (L/R=7ms)
0.1
10
100
500 1,000
Contact voltage, V
DIMENSIONS (Unit: mm inch)
2 Form C
External dimensions
Schematic (Bottom view)
2.5 dia. 9 deep hole for
7
2
8.4
.331
7
.276
3 dia. tapping screw
8
6
5
1
3
4
.098 dia. .354 deep hole for
.118 dia. tapping screw
16
.630
20.5
.807
2.5 dia. 8 deep hole for
3 dia. tapping screw
.098 dia. .315 deep hole for
.118 dia. tapping screw
15
.591
34
1.339
36
1.417
56
2.205
4
.157
8.5
.335
Compatible with tab terminal
#250 series receptacle.
7
.276
10.5
.413
7.5
.295
7.26
.286
17
.669
General tolerance: 0.5 .020
3 Form C
External dimensions
Schematic (Bottom view)
2.5 dia. 9 deep hole for
3 dia. tapping screw
.098 dia. .354 deep hole for
.118 dia. tapping screw
10
2
8.4
8.4
7
.276
.331 .331
11
9
8
1
4
5
3
6
7
16
.630
20.5
.807
2.5 dia. 8 deep hole for
3 dia. tapping screw
.098 dia. .315 deep hole for
.118 dia. tapping screw
17
.669
50
1.969
36
1.417
56
2.205
4
.157
8.5
.335
Compatible with tab terminal
#250 series receptacle.
7
.276
10.5
.413
7.5
.295
7.26
.286
17
17
.669 .669
General tolerance: 0.5 .020
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HG
4 Form C
External dimensions
Schematic (Bottom view)
2.5 dia. 9 deep hole for
10
1
8.4
.331
8.4
.331
7
.276
3 dia. tapping screw
9
8
7
2
3
4
.098 dia. .354 deep hole for
.118 dia. tapping screw
15 11
14 12
6 5
16
.630
20.5
.807
2.5 dia. 8 deep hole for
3 dia. tapping screw
.098 dia. .315 deep hole for
.118 dia. tapping screw
34
1.339
68
2.677
36
1.417
56
2.205
4
.157
8.5
.335
Compatible with tab terminal
#250 series receptacle.
7
.276
10.5
.413
7.5
.295
7.26
.286
17
17
17
.669 .669 .669
General tolerance: 0.5 .020
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
相关型号:
HG2-DC110V
Power/Signal Relay, DPDT, Momentary, 0.014A (Coil), 110VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount,
PANASONIC
HG2-DC12V
Power/Signal Relay, DPDT, Momentary, 0.12A (Coil), 12VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount,
PANASONIC
HG2-DC200V
Power/Signal Relay, DPDT, Momentary, 0.007A (Coil), 200VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount,
PANASONIC
HG2-DC48V
Power/Signal Relay, DPDT, Momentary, 0.03A (Coil), 48VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount,
PANASONIC
HG2-DC6V
Power/Signal Relay, DPDT, Momentary, 0.23A (Coil), 6VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount
PANASONIC
©2020 ICPDF网 联系我们和版权申明