QPQ1029 [QORVO]
Band 1 and Band 3 Dual Filter;型号: | QPQ1029 |
厂家: | Qorvo |
描述: | Band 1 and Band 3 Dual Filter |
文件: | 总16页 (文件大小:1235K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
QPQ1029
Band 1 and Band 3 Dual Filter
®
Product Overview
QPQ1029 is a high performance, Bulk Acoustic Wave
(BAW) dual band filter module designed for Band 1 Uplink
& Band 3 Uplink
The QPQ1029 provides low insertion loss and very high
rejection, making it an ideal choice for small cell. This
diplexer is housed in a compact ROHs compliant 3x3 mm
surface mount package.
16 Pad 3ꢀxꢀ3ꢀmm SMT Package
The QPQ1029 is part of Qorvo’s extensive portfolio of RF
BAW and SAW filters.
Key Features
• 60 MHz Bandwidth for Band 1 Uplink
• 75 MHz Bandwidth for Band 3 Uplink
• Low Loss and High Attenuation
• +29dBm Power Handling for Small Cell Application
• Single Ended Operation to 50 Ω
• No External Matching Required
• RoHS Compliant, Pb-Free
Functional Block Diagram
Pb
Applications
• B3 Uplink and B1 Uplink
• Base Station Infrastructure
• Small Cells
• Repeaters
• LTE Dongles
• General Purpose Wireless
Top View
Pin Configuration
Pin No.
2
Label
INPUT
Ordering Information
11
OUTPUT
Part No.
Description
1,3,4,5,6,7,8,9,10,12,13,14,
15,16, Back Side Center Pad
QPQ1029TR7
QPQ1029EVB
2,500 pieces on a 7” reel (standard)
GND
Evaluation Board
Datasheet Rev E, January 10, 2020 | Subject to change without notice
1 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
Absolute Maximum Ratings (1)
Minimum Lifetime Rating
Parameter
Rating
Conditions
Rating
Storage Temperature
Operating Temperature (2)
Notes:
−40 to +125ꢁ°C
−40 to +95ꢁ°C
+29dBm Apply to Pin 2 Input, +95°C,
LTE 5 MHz, 16 QAM, PAR 8dB,
Frequency 1785MHz or 1980 MHz
>87,600 hours
1. Operation of this device outside of the parameter ranges may cause
permanent damage.
2. Device will be functional, but is not guaranteed to meet electrical
specifications
Electrical Specifications (1) (2) (3)
Test Conditions unless otherwise noted= -20°C to +85°C
Parameter
Conditions
Min
Typ (4)
-
Max
1785
1980
3.5
2.7
2.4
1.6
2.0:1
2.0:1
2.0:1
2.0:1
-
Units
MHz
MHz
dB
Passband Frequency, B3UL
Passband Frequency, B1UL
Integrated Insertion Loss (5) B3UL
Integrated Insertion Loss (5) B1UL
Amplitude Ripple (6) B3UL
Amplitude Ripple (6) B1UL
Input VSWR B3UL
1710
1920
-
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
-
2.5
2.1
0.8
0.6
1.6:1
1.4:1
1.6:1
1.5:1
13
-
dB
-
dB
-
-
dB
ratio
ratio
ratio
ratio
dB
Input VSWR B1UL
-
Output VSWR B3UL
-
Output VSWR B1UL
-
Input Return Loss B3UL (8)
Input Return Loss B1UL (8)
Output Return Loss B3UL (8)
Output Return Loss B1UL (8)
Group Delay Variation B3UL (7)
Group Delay Variation B1UL (7)
Notes:
9.5
9.5
9.5
9.5
-
16
-
dB
12
-
dB
14
-
dB
8
24
ns
-
5
20
ns
1. All specifications are based on the Qorvo test circuit shown on page 11
2. In production, devices are tested at room temperature with guard-banded specifications to ensure electrical compliance over temperature
3. Electrical margin has been designed into account for the variations due to temperature drift and manufacturing tolerances
4. Typical values are based on average measurements at room temperature of 25°C
5. Insertion Loss is Integrated over any 5MHz bandwidth within the defined frequency band
6. This is defined as the worst difference between a peak and adjacent valley over any 5 MHz window within the frequency band
7. Measured over any 5 MHz window within the frequency band
8. This Parameter is guaranteed by design, and will not be tested in production
Datasheet Rev E, January 10, 2020 | Subject to change without notice
2 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
Electrical Specifications (1) (2) (3)
Test Conditions unless otherwise noted= -20°C to +85°C
Parameter
Conditions
0-729 MHz
Min
31
42
31
33
10
45
26
45
26
45
35
21
47
26
30
11
11
-
Typ (4)
50
Max
Units
-
-
-
-
-
-
-
-
-
-
-
-
-
45
729-960 MHz
960-1475 MHz
40
35
1475-1559 MHz
1559-1690 MHz (5)
1805-1880 MHz (5)
2025-2110 MHz
2110-2170 MHz (5)
2170-2288 MHz
2300-2400 MHz
2400-2690 MHz
2690-3400 MHz
3400-3800 MHz
3800-4600 MHz
4600-5000 MHz
5000-8000 MHz
8000-12750 MHz (11)
30
49
26
53
52
49
45
Attenuation (6)
dB
44
56
36
-
-
39
27
-
-
-
-
-
26
Load/Source Impedance (7)
50
Ω
IMD5-H(9) at Output P2 (B1UL)
IMD5-L(10) at Output P2 (B3UL)
-
-117
-112
dBm
dBm
PIM5 (8)
-
Notes:
1. All specifications are based on the Qorvo test circuit shown on page 11
2. In production, devices are tested at room temperature with guard-banded specifications to ensure electrical compliance over temperature.
3. Electrical margin has been designed into account for the variations due to temperature drift and manufacturing tolerances
4. Typical values are based on average measurements at room temperature of 25°C
5. Integrated attenuation over any 5 MHz bandwidth within the specified frequency range
6. Relative to zero dB
7. This is the optimum impedance in order to achieve the performance shown.
8. With 2 tones, F1 and F2, +23dBm/tone applied to INPUT P1. The F1 and F2 are selected from 1805 to1880 MHz to have the IMD5 in B1 UL or
B3 UL frequency range. The noise floor of the measurement system is -140 dBm. The PIM is guaranteed by design and not tested in production.
9. IMD5-H (3*F2-2*F1) at Band 1 UL frequency range
10. IMD5-L (3*F1-2*F2) at Band 3 UL frequency range
11. This attenuation is guaranteed by design, and will not be tested in production
Datasheet Rev E, January 10, 2020 | Subject to change without notice
3 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
Electrical Specifications (1) (2) (3)
Test Conditions unless otherwise noted= -40°C to +95°C
Parameter
Conditions
Min
Typ (4)
-
Max
1785
1980
3.8
2.9
2.5
1.8
2.1:1
2.1:1
2.1:1
2.1:1
-
Units
MHz
MHz
dB
Passband Frequency, B3UL
Passband Frequency, B1UL
Integrated Insertion Loss (5) B3UL
Integrated Insertion Loss (5) B1UL
Amplitude Ripple (6) B3UL
Amplitude Ripple (6) B1UL
Input VSWR B3UL
1710
1920
-
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
1710 MHz – 1785 MHz
1920 MHz – 1980 MHz
-
2.5
2.1
0.8
0.6
1.6:1
1.4:1
1.6:1
1.5:1
13
-
-
dB
dB
-
dB
-
ratio
ratio
ratio
ratio
dB
Input VSWR B1UL
-
Output VSWR B3UL
-
Output VSWR B1UL
-
Input Return Loss B3UL (8)
Input Return Loss B1UL (8)
Output Return Loss B3UL (8)
Output Return Loss B1UL (8)
Group Delay Variation B3UL (7)
Group Delay Variation B1UL (7)
Notes:
9.0
9.0
9.0
9.0
16
-
dB
12
-
dB
14
-
dB
8
26
ns
5
22
ns
1. All specifications are based on the Qorvo test circuit shown on page 11.
2. In production, devices will be tested at room temperature with guard-banded specifications to ensure electrical compliance over temperature.
3. Electrical margin has been designed into account for the variations due to temperature drift and manufacturing tolerances
4. Typical values are based on average measurements at room temperature of 25°C
5. Insertion Loss is Integrated over any 5MHz bandwidth within defined frequency band
6. This is defined as the worst difference between a peak and adjacent valley within any 5 MHz window within the frequency band
7. Measured over any 5 MHz window within the frequency band
8. This Parameter is guaranteed by design, and will not be tested in production
Datasheet Rev E, January 10, 2020 | Subject to change without notice
4 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
De-Embedded Electrical Specifications (1) (2) (3)
Test Conditions unless otherwise noted= -40°C to +95°C
Parameter
Conditions
0-729 MHz
Min
31
42
31
33
7
Typ. (4)
50
Max
Units
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
45
729-960 MHz
960-1475 MHz
40
35
1475-1559 MHz
1559-1690 MHz (5)
1805-1880 MHz (5)
2025-2110 MHz
2110-2170 MHz (5)(11)
2170-2288 MHz
2300-2400 MHz
2400-2690 MHz
2690-3400 MHz
3400-3800 MHz
3800-4600 MHz
4600-5000 MHz
5000-8000 MHz
8000-12750 MHz (11)
30
43
26
45
26
45
35
21
47
26
30
11
11
-
49
26
53
52
49
45
Attenuation (6)
dB
44
56
36
39
27
26
Load/Source Impedance (6)
50
Ω
IMD5-H (9) at Output P2 (B1UL)
IMD5-L (10) at Output P2 (B3UL)
-
-117
-112
dBm
dBm
PIM5 (8)
-
Notes:
1. All specifications are based on the Qorvo test circuit shown on page 11.
2. In production, devices will be tested at room temperature with guard-banded specifications to ensure electrical compliance over temperature.
3. Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing tolerances
4. Typical values are based on average measurements at room temperature of 25°C
5. Integrated Rejection over 5 MHz bandwidth.
6. Relative to zero dB.
7. This is the optimum impedance in order to achieve the performance shown.
8. With 2 Tones, F1 and F2, +23dBm/tone applied to INPUT P1. F1 and F2 are selected from 1805 to1880 MHz to have IMD5 in B1 UL or B3 UL
frequency range. The noise floor of the measurement system is -140 dBm. PIM is guaranteed by design, and not tested in production.
9. IMD5-H (3*F2-2*F1) in Band 1 UL frequency range
10. IMD5-L (3*F1-2*F2) in Band 3 UL frequency range
11. This attenuation is guaranteed by design, and will not be tested in production
Datasheet Rev E, January 10, 2020 | Subject to change without notice
5 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
De-embedded Performance Plots – Band 3
Test conditions unless otherwise noted: Temp.=+25ꢀ°C
Narrow Band B3
Passband Response B3
0
-1
-3
-5
-7
-9
-10
-20
-30
d
B
d
B
-40
-50
-60
-70
1687.5
1717.5
1747.5
1777.5
1807.5
1607.5
1677.5
1747.5
1817.5
1887.5
Frequency (MHz)
Frequency (MHz)
Frequency Response B3 and B1
Group Delay Response B3
0
-10
-20
-30
-40
-50
-60
-70
50
35
20
5
n
s
e
c
d
B
-10
1500
1675
1850
2025
2200
1672.5
1710
1747.5
1785
1822.5
Frequency (MHz)
Frequency (MHz)
Ouput Return Loss - S22 B3
Input Return Loss - S11 B3
0
-5
0
-5
-10
-15
-20
-25
-10
-15
-20
-25
d
B
d
B
1687.5
1717.5
1747.5
1777.5
1807.5
1687.5
1717.5
1747.5
1777.5
1807.5
Frequency (MHz)
Frequency (MHz)
Datasheet Rev E, January 10, 2020 | Subject to change without notice
6 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
De-embedded Performance Plots – Band 3
Test conditions unless otherwise noted: Temp.=+25ꢀ°C
S22-B3 VSWR
S11-B3 VSWR
3
2.5
2
3
L
L
i
n
e
a
r
i
n
e
a
r
2.5
2
M
a
M
a
1.5
1.5
g
g
1
1
1672.5
1710
1747.5
1785
1822.5
1672.5
1710
1747.5
1785
1822.5
Frequency (MHz)
Frequency (MHz)
S11-B3 UL
S22-B3 UL
1
1
0.8
0.6
0.4
0.2
0.8
0.6
0.4
0.2
0
0
0
0
-1
-0.5
0.5
1
-1
-0.5
0.5
1
-0.2
-0.4
-0.6
-0.8
-1
-0.2
-0.4
-0.6
-0.8
-1
Datasheet Rev E, January 10, 2020 | Subject to change without notice
7 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
De-embedded Performance Plots – Band 1
Test conditions unless otherwise noted: Temp.=+25ꢀ°C
Narrow Band B1
Passband Response B1
0
-1
-3
-5
-7
-9
-10
-20
-30
d
B
d
B
-40
-50
-60
-70
1825
1887.5
1950
2012.5
2075
1890
1920
1950
1980
2010
Frequency (MHz)
Frequency (MHz)
Group Delay Response B1
Frequency Response B3 and B1
45
35
25
15
5
0
-10
-20
-30
-40
-50
-60
-70
n
s
e
c
d
B
1890
1920
1950
1980
2010
1500
1675
1850
2025
2200
Frequency (MHz)
Frequency (MHz)
Input Return Loss - S11 B1
Ouput Return Loss -S22 B1
0
-5
0
-5
-10
-15
-20
-25
-10
-15
-20
-25
d
B
d
B
1890
1920
1950
1980
2010
1890
1920
1950
1980
2010
Frequency (MHz)
Frequency (MHz)
Datasheet Rev E, January 10, 2020 | Subject to change without notice
8 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
De-embedded Performance Plots – Band 1
Test conditions unless otherwise noted: Temp.=+25ꢀ°C
S22-B1 VSWR
S11-B1 VSWR
3
2.5
2
3
L
i
n
e
L
i
n
e
a
r
2.5
a
2
r
M
a
M
a
1.5
1.5
g
g
1
1
1890
1920
1950
1980
2010
1890
1920
1950
1980
2010
Frequency (MHz)
Frequency (MHz)
S11-B1 UL
S22-B1 UL
1
1
0.8
0.6
0.4
0.2
0.8
0.6
0.4
0.2
0
0
0
0
-1
-0.5
0.5
1
-1
-0.5
0.5
1
-0.2
-0.4
-0.6
-0.8
-1
-0.2
-0.4
-0.6
-0.8
-1
Datasheet Rev E, January 10, 2020 | Subject to change without notice
9 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
De-embedded Performance Plots – Band 1 and Band 3, Wideband
Test conditions unless otherwise noted: Temp.=+25ꢀ°C
Wideband Response
0
-10
-20
-30
d
B
-40
-50
-60
-70
700
1775
2850
3925
5000
Frequency (MHz)
Very Wideband Response
0
-10
-20
-30
-40
-50
-60
-70
d
B
10
3195
6380
9565
12750
Frequency (MHz)
Datasheet Rev E, January 10, 2020 | Subject to change without notice
10 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
Evaluation Board and Circuit
Bill of Material ꢀ–ꢀ QPQ1029EVB
Ref. Des.
Value
Description
Manuf.
Qorvo
Qorvo
Cinch
Part Number
QPQ1029
U1
-
-
-
Filter, Band 1 and Band 3 Dual Band
PCB, Printed Circuit Board
Connector, SMA Edge Mount
-
-
290913
142-0701-851
Evaluation Board PCB Information
PC Board Layout
PCB 290913 Material (stack up)
50 Ω line dimensions: width = 0.012”, spacing = 0.004”
Datasheet Rev E, January 10, 2020 | Subject to change without notice
11 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
Package Marking and Dimensions
Marking: Qorvo Logo
Part Number – 1029
Trace Code –ꢁAssigned by subcontractor
Notes:
1. All dimensions are in millimeters. Angles are in degrees.
2. The terminal #1 identifier and terminal numbering conform to JESD 95-1 SPP-012.
3. Contact plating: Electroless NiPdAu
PCB Mounting Pattern
Notes:
1. All dimensions are in millimeters. Angles are in degrees.
.
Datasheet Rev E, January 10, 2020 | Subject to change without notice
12 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
Tape and Reel Information – Carrier and Cover Tape Dimensions
Feature
Measure
Symbol
Size (in)
0.132
0.132
0.051
0.315
0.079
0.138
0.362
0.315
Size (mm)
3.35
Length
A0
B0
K0
P1
P2
F
Width
3.35
Cavity
Depth
1.30
Pitch
4.00
Cavity to Perforation - Length Direction
2.00
Centerline Distance
Cavity to Perforation - Width Direction
3.50
Cover Tape
Carrier Tape
Width
Width
C
5.40
W
8.00
Datasheet Rev E, January 10, 2020 | Subject to change without notice
13 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
Tape and Reel Information – Reel Dimensions
Standard T/R size = 2500 pieces on a 7” reel.
Feature
Measure
Diameter
Symbol
Size (in)
6.969
Size (mm)
177.0
A
Flange
Thickness
W2
0.559
14.2
Space Between Flange
Outer Diameter
W1
N
0.346
2.283
0.512
0.079
0.787
8.8
58.0
13.0
2.0
Arbor Hole Diameter
Key Slit Width
C
Hub
B
Key Slit Diameter
D
20.0
Tape and Reel Information – Tape Length and Label Placement
Notes:
1. Empty part cavities at the trailing and leading ends are sealed with cover tape. See EIA 481-1-A.
2. Labels are placed on the flange opposite the sprockets in the carrier tape.
Datasheet Rev E, January 10, 2020 | Subject to change without notice
14 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
Assembly Notes
Compatible with both lead-free (260°C peak. reflow temp.) and tin/lead (245°C peak. reflow temp.) soldering processes.
The use of no-clean solder to avoid washing after soldering is recommended.
Contact plating: Electroless NiPdAu (Plating thickness: Ni 0.4±0.10μm, Pd 0.145±0.035μm, Au 0.095±0.025μm)
Recommended Soldering Temperature Profile
Datasheet Rev E, January 10, 2020 | Subject to change without notice
15 of 16
www.qorvo.com
QPQ1029
®
Band 1 and Band 3 Dual Filter
Handling Precautions
Parameter
Rating
Standard
ESDꢁ–ꢁHuman Body Model (HBM)
Class 1C
ESDAꢀ/ꢀJEDEC JS-001-2012
JEDEC JESD22-C101F
IPC/JEDEC J-STD-020
Caution!
ESD-Sensitive Device
ESDꢁ–ꢁCharged Device Model (CDM) Class C3
MSLꢁ–ꢁMoisture Sensitivity Level
Level 3
RoHS Compliance
This part is compliant with 2011/65/EU RoHS directive (Restrictions on the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment) as amended by Directive 2015/863/EU.
This product also has the following attributes:
• Lead Free
• Halogen Free (Chlorine, Bromine)
• Antimony Free
• TBBP-A (C15H12Br402) Free
• PFOS Free
• SVHC Free
Pb
Contact Information
For the latest specifications, additional product information, worldwide sales and distribution locations:
Web: www.qorvo.com
Tel: 1-844-890-8163
Email: customer.support@qorvo.com
Important Notice
The information contained herein is believed to be reliable; however, Qorvo makes no warranties regarding the information contained
herein and assumes no responsibility or liability whatsoever for the use of the information contained herein. All information contained
herein is subject to change without notice. Customers should obtain and verify the latest relevant information before placing orders for
Qorvo products. The information contained herein, or any use of such information does not grant, explicitly or implicitly, to any party any
patent rights, licenses, or any other intellectual property rights, whether with regard to such information itself or anything described by
such information. THIS INFORMATION DOES NOT CONSTITUTE A WARRANTY WITH RESPECT TO THE PRODUCTS DESCRIBED
HEREIN, AND QORVO HEREBY DISCLAIMS ANY AND ALL WARRANTIES WITH RESPECT TO SUCH PRODUCTS WHETHER
EXPRESS OR IMPLIED BY LAW, COURSE OF DEALING, COURSE OF PERFORMANCE, USAGE OF TRADE OR OTHERWISE,
INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Without limiting the generality of the foregoing, Qorvo products are not warranted or authorized for use as critical components in medical,
lifesaving, or life-sustaining applications, or other applications where a failure would reasonably be expected to cause severe personal
injury or death.
Copyright 2019 © Qorvo, Inc. | Qorvo is a registered trademark of Qorvo, Inc.
Datasheet Rev E, January 10, 2020 | Subject to change without notice
16 of 16
www.qorvo.com
相关型号: