QPQ1029 [QORVO]

Band 1 and Band 3 Dual Filter;
QPQ1029
型号: QPQ1029
厂家: Qorvo    Qorvo
描述:

Band 1 and Band 3 Dual Filter

文件: 总16页 (文件大小:1235K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
QPQ1029  
Band 1 and Band 3 Dual Filter  
®
Product Overview  
QPQ1029 is a high performance, Bulk Acoustic Wave  
(BAW) dual band filter module designed for Band 1 Uplink  
& Band 3 Uplink  
The QPQ1029 provides low insertion loss and very high  
rejection, making it an ideal choice for small cell. This  
diplexer is housed in a compact ROHs compliant 3x3 mm  
surface mount package.  
16 Pad 3x3mm SMT Package  
The QPQ1029 is part of Qorvo’s extensive portfolio of RF  
BAW and SAW filters.  
Key Features  
60 MHz Bandwidth for Band 1 Uplink  
75 MHz Bandwidth for Band 3 Uplink  
Low Loss and High Attenuation  
+29dBm Power Handling for Small Cell Application  
Single Ended Operation to 50 Ω  
No External Matching Required  
RoHS Compliant, Pb-Free  
Functional Block Diagram  
Pb  
Applications  
B3 Uplink and B1 Uplink  
Base Station Infrastructure  
Small Cells  
Repeaters  
LTE Dongles  
General Purpose Wireless  
Top View  
Pin Configuration  
Pin No.  
2
Label  
INPUT  
Ordering Information  
11  
OUTPUT  
Part No.  
Description  
1,3,4,5,6,7,8,9,10,12,13,14,  
15,16, Back Side Center Pad  
QPQ1029TR7  
QPQ1029EVB  
2,500 pieces on a 7” reel (standard)  
GND  
Evaluation Board  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
1 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
Absolute Maximum Ratings (1)  
Minimum Lifetime Rating  
Parameter  
Rating  
Conditions  
Rating  
Storage Temperature  
Operating Temperature (2)  
Notes:  
40 to +125ꢁ°C  
40 to +95ꢁ°C  
+29dBm Apply to Pin 2 Input, +95°C,  
LTE 5 MHz, 16 QAM, PAR 8dB,  
Frequency 1785MHz or 1980 MHz  
>87,600 hours  
1. Operation of this device outside of the parameter ranges may cause  
permanent damage.  
2. Device will be functional, but is not guaranteed to meet electrical  
specifications  
Electrical Specifications (1) (2) (3)  
Test Conditions unless otherwise noted= -20°C to +85°C  
Parameter  
Conditions  
Min  
Typ (4)  
-
Max  
1785  
1980  
3.5  
2.7  
2.4  
1.6  
2.0:1  
2.0:1  
2.0:1  
2.0:1  
-
Units  
MHz  
MHz  
dB  
Passband Frequency, B3UL  
Passband Frequency, B1UL  
Integrated Insertion Loss (5) B3UL  
Integrated Insertion Loss (5) B1UL  
Amplitude Ripple (6) B3UL  
Amplitude Ripple (6) B1UL  
Input VSWR B3UL  
1710  
1920  
-
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
-
2.5  
2.1  
0.8  
0.6  
1.6:1  
1.4:1  
1.6:1  
1.5:1  
13  
-
dB  
-
dB  
-
-
dB  
ratio  
ratio  
ratio  
ratio  
dB  
Input VSWR B1UL  
-
Output VSWR B3UL  
-
Output VSWR B1UL  
-
Input Return Loss B3UL (8)  
Input Return Loss B1UL (8)  
Output Return Loss B3UL (8)  
Output Return Loss B1UL (8)  
Group Delay Variation B3UL (7)  
Group Delay Variation B1UL (7)  
Notes:  
9.5  
9.5  
9.5  
9.5  
-
16  
-
dB  
12  
-
dB  
14  
-
dB  
8
24  
ns  
-
5
20  
ns  
1. All specifications are based on the Qorvo test circuit shown on page 11  
2. In production, devices are tested at room temperature with guard-banded specifications to ensure electrical compliance over temperature  
3. Electrical margin has been designed into account for the variations due to temperature drift and manufacturing tolerances  
4. Typical values are based on average measurements at room temperature of 25°C  
5. Insertion Loss is Integrated over any 5MHz bandwidth within the defined frequency band  
6. This is defined as the worst difference between a peak and adjacent valley over any 5 MHz window within the frequency band  
7. Measured over any 5 MHz window within the frequency band  
8. This Parameter is guaranteed by design, and will not be tested in production  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
2 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
Electrical Specifications (1) (2) (3)  
Test Conditions unless otherwise noted= -20°C to +85°C  
Parameter  
Conditions  
0-729 MHz  
Min  
31  
42  
31  
33  
10  
45  
26  
45  
26  
45  
35  
21  
47  
26  
30  
11  
11  
-
Typ (4)  
50  
Max  
Units  
-
-
-
-
-
-
-
-
-
-
-
-
-
45  
729-960 MHz  
960-1475 MHz  
40  
35  
1475-1559 MHz  
1559-1690 MHz (5)  
1805-1880 MHz (5)  
2025-2110 MHz  
2110-2170 MHz (5)  
2170-2288 MHz  
2300-2400 MHz  
2400-2690 MHz  
2690-3400 MHz  
3400-3800 MHz  
3800-4600 MHz  
4600-5000 MHz  
5000-8000 MHz  
8000-12750 MHz (11)  
30  
49  
26  
53  
52  
49  
45  
Attenuation (6)  
dB  
44  
56  
36  
-
-
39  
27  
-
-
-
-
-
26  
Load/Source Impedance (7)  
50  
IMD5-H(9) at Output P2 (B1UL)  
IMD5-L(10) at Output P2 (B3UL)  
-
-117  
-112  
dBm  
dBm  
PIM5 (8)  
-
Notes:  
1. All specifications are based on the Qorvo test circuit shown on page 11  
2. In production, devices are tested at room temperature with guard-banded specifications to ensure electrical compliance over temperature.  
3. Electrical margin has been designed into account for the variations due to temperature drift and manufacturing tolerances  
4. Typical values are based on average measurements at room temperature of 25°C  
5. Integrated attenuation over any 5 MHz bandwidth within the specified frequency range  
6. Relative to zero dB  
7. This is the optimum impedance in order to achieve the performance shown.  
8. With 2 tones, F1 and F2, +23dBm/tone applied to INPUT P1. The F1 and F2 are selected from 1805 to1880 MHz to have the IMD5 in B1 UL or  
B3 UL frequency range. The noise floor of the measurement system is -140 dBm. The PIM is guaranteed by design and not tested in production.  
9. IMD5-H (3*F2-2*F1) at Band 1 UL frequency range  
10. IMD5-L (3*F1-2*F2) at Band 3 UL frequency range  
11. This attenuation is guaranteed by design, and will not be tested in production  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
3 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
Electrical Specifications (1) (2) (3)  
Test Conditions unless otherwise noted= -40°C to +95°C  
Parameter  
Conditions  
Min  
Typ (4)  
-
Max  
1785  
1980  
3.8  
2.9  
2.5  
1.8  
2.1:1  
2.1:1  
2.1:1  
2.1:1  
-
Units  
MHz  
MHz  
dB  
Passband Frequency, B3UL  
Passband Frequency, B1UL  
Integrated Insertion Loss (5) B3UL  
Integrated Insertion Loss (5) B1UL  
Amplitude Ripple (6) B3UL  
Amplitude Ripple (6) B1UL  
Input VSWR B3UL  
1710  
1920  
-
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
1710 MHz 1785 MHz  
1920 MHz 1980 MHz  
-
2.5  
2.1  
0.8  
0.6  
1.6:1  
1.4:1  
1.6:1  
1.5:1  
13  
-
-
dB  
dB  
-
dB  
-
ratio  
ratio  
ratio  
ratio  
dB  
Input VSWR B1UL  
-
Output VSWR B3UL  
-
Output VSWR B1UL  
-
Input Return Loss B3UL (8)  
Input Return Loss B1UL (8)  
Output Return Loss B3UL (8)  
Output Return Loss B1UL (8)  
Group Delay Variation B3UL (7)  
Group Delay Variation B1UL (7)  
Notes:  
9.0  
9.0  
9.0  
9.0  
16  
-
dB  
12  
-
dB  
14  
-
dB  
8
26  
ns  
5
22  
ns  
1. All specifications are based on the Qorvo test circuit shown on page 11.  
2. In production, devices will be tested at room temperature with guard-banded specifications to ensure electrical compliance over temperature.  
3. Electrical margin has been designed into account for the variations due to temperature drift and manufacturing tolerances  
4. Typical values are based on average measurements at room temperature of 25°C  
5. Insertion Loss is Integrated over any 5MHz bandwidth within defined frequency band  
6. This is defined as the worst difference between a peak and adjacent valley within any 5 MHz window within the frequency band  
7. Measured over any 5 MHz window within the frequency band  
8. This Parameter is guaranteed by design, and will not be tested in production  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
4 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
De-Embedded Electrical Specifications (1) (2) (3)  
Test Conditions unless otherwise noted= -40°C to +95°C  
Parameter  
Conditions  
0-729 MHz  
Min  
31  
42  
31  
33  
7
Typ. (4)  
50  
Max  
Units  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
45  
729-960 MHz  
960-1475 MHz  
40  
35  
1475-1559 MHz  
1559-1690 MHz (5)  
1805-1880 MHz (5)  
2025-2110 MHz  
2110-2170 MHz (5)(11)  
2170-2288 MHz  
2300-2400 MHz  
2400-2690 MHz  
2690-3400 MHz  
3400-3800 MHz  
3800-4600 MHz  
4600-5000 MHz  
5000-8000 MHz  
8000-12750 MHz (11)  
30  
43  
26  
45  
26  
45  
35  
21  
47  
26  
30  
11  
11  
-
49  
26  
53  
52  
49  
45  
Attenuation (6)  
dB  
44  
56  
36  
39  
27  
26  
Load/Source Impedance (6)  
50  
IMD5-H (9) at Output P2 (B1UL)  
IMD5-L (10) at Output P2 (B3UL)  
-
-117  
-112  
dBm  
dBm  
PIM5 (8)  
-
Notes:  
1. All specifications are based on the Qorvo test circuit shown on page 11.  
2. In production, devices will be tested at room temperature with guard-banded specifications to ensure electrical compliance over temperature.  
3. Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing tolerances  
4. Typical values are based on average measurements at room temperature of 25°C  
5. Integrated Rejection over 5 MHz bandwidth.  
6. Relative to zero dB.  
7. This is the optimum impedance in order to achieve the performance shown.  
8. With 2 Tones, F1 and F2, +23dBm/tone applied to INPUT P1. F1 and F2 are selected from 1805 to1880 MHz to have IMD5 in B1 UL or B3 UL  
frequency range. The noise floor of the measurement system is -140 dBm. PIM is guaranteed by design, and not tested in production.  
9. IMD5-H (3*F2-2*F1) in Band 1 UL frequency range  
10. IMD5-L (3*F1-2*F2) in Band 3 UL frequency range  
11. This attenuation is guaranteed by design, and will not be tested in production  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
5 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
De-embedded Performance Plots Band 3  
Test conditions unless otherwise noted: Temp.=+25ꢀ°C  
Narrow Band B3  
Passband Response B3  
0
-1  
-3  
-5  
-7  
-9  
-10  
-20  
-30  
d
B
d
B
-40  
-50  
-60  
-70  
1687.5  
1717.5  
1747.5  
1777.5  
1807.5  
1607.5  
1677.5  
1747.5  
1817.5  
1887.5  
Frequency (MHz)  
Frequency (MHz)  
Frequency Response B3 and B1  
Group Delay Response B3  
0
-10  
-20  
-30  
-40  
-50  
-60  
-70  
50  
35  
20  
5
n
s
e
c
d
B
-10  
1500  
1675  
1850  
2025  
2200  
1672.5  
1710  
1747.5  
1785  
1822.5  
Frequency (MHz)  
Frequency (MHz)  
Ouput Return Loss - S22 B3  
Input Return Loss - S11 B3  
0
-5  
0
-5  
-10  
-15  
-20  
-25  
-10  
-15  
-20  
-25  
d
B
d
B
1687.5  
1717.5  
1747.5  
1777.5  
1807.5  
1687.5  
1717.5  
1747.5  
1777.5  
1807.5  
Frequency (MHz)  
Frequency (MHz)  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
6 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
De-embedded Performance Plots Band 3  
Test conditions unless otherwise noted: Temp.=+25°C  
S22-B3 VSWR  
S11-B3 VSWR  
3
2.5  
2
3
L
L
i
n
e
a
r
i
n
e
a
r
2.5  
2
M
a
M
a
1.5  
1.5  
g
g
1
1
1672.5  
1710  
1747.5  
1785  
1822.5  
1672.5  
1710  
1747.5  
1785  
1822.5  
Frequency (MHz)  
Frequency (MHz)  
S11-B3 UL  
S22-B3 UL  
1
1
0.8  
0.6  
0.4  
0.2  
0.8  
0.6  
0.4  
0.2  
0
0
0
0
-1  
-0.5  
0.5  
1
-1  
-0.5  
0.5  
1
-0.2  
-0.4  
-0.6  
-0.8  
-1  
-0.2  
-0.4  
-0.6  
-0.8  
-1  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
7 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
De-embedded Performance Plots Band 1  
Test conditions unless otherwise noted: Temp.=+25ꢀ°C  
Narrow Band B1  
Passband Response B1  
0
-1  
-3  
-5  
-7  
-9  
-10  
-20  
-30  
d
B
d
B
-40  
-50  
-60  
-70  
1825  
1887.5  
1950  
2012.5  
2075  
1890  
1920  
1950  
1980  
2010  
Frequency (MHz)  
Frequency (MHz)  
Group Delay Response B1  
Frequency Response B3 and B1  
45  
35  
25  
15  
5
0
-10  
-20  
-30  
-40  
-50  
-60  
-70  
n
s
e
c
d
B
1890  
1920  
1950  
1980  
2010  
1500  
1675  
1850  
2025  
2200  
Frequency (MHz)  
Frequency (MHz)  
Input Return Loss - S11 B1  
Ouput Return Loss -S22 B1  
0
-5  
0
-5  
-10  
-15  
-20  
-25  
-10  
-15  
-20  
-25  
d
B
d
B
1890  
1920  
1950  
1980  
2010  
1890  
1920  
1950  
1980  
2010  
Frequency (MHz)  
Frequency (MHz)  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
8 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
De-embedded Performance Plots Band 1  
Test conditions unless otherwise noted: Temp.=+25°C  
S22-B1 VSWR  
S11-B1 VSWR  
3
2.5  
2
3
L
i
n
e
L
i
n
e
a
r
2.5  
a
2
r
M
a
M
a
1.5  
1.5  
g
g
1
1
1890  
1920  
1950  
1980  
2010  
1890  
1920  
1950  
1980  
2010  
Frequency (MHz)  
Frequency (MHz)  
S11-B1 UL  
S22-B1 UL  
1
1
0.8  
0.6  
0.4  
0.2  
0.8  
0.6  
0.4  
0.2  
0
0
0
0
-1  
-0.5  
0.5  
1
-1  
-0.5  
0.5  
1
-0.2  
-0.4  
-0.6  
-0.8  
-1  
-0.2  
-0.4  
-0.6  
-0.8  
-1  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
9 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
De-embedded Performance Plots Band 1 and Band 3, Wideband  
Test conditions unless otherwise noted: Temp.=+25°C  
Wideband Response  
0
-10  
-20  
-30  
d
B
-40  
-50  
-60  
-70  
700  
1775  
2850  
3925  
5000  
Frequency (MHz)  
Very Wideband Response  
0
-10  
-20  
-30  
-40  
-50  
-60  
-70  
d
B
10  
3195  
6380  
9565  
12750  
Frequency (MHz)  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
10 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
Evaluation Board and Circuit  
Bill of Material ꢀ–ꢀ QPQ1029EVB  
Ref. Des.  
Value  
Description  
Manuf.  
Qorvo  
Qorvo  
Cinch  
Part Number  
QPQ1029  
U1  
-
-
-
Filter, Band 1 and Band 3 Dual Band  
PCB, Printed Circuit Board  
Connector, SMA Edge Mount  
-
-
290913  
142-0701-851  
Evaluation Board PCB Information  
PC Board Layout  
PCB 290913 Material (stack up)  
50 line dimensions: width = 0.012”, spacing = 0.004”  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
11 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
Package Marking and Dimensions  
Marking: Qorvo Logo  
Part Number 1029  
Trace Code –ꢁAssigned by subcontractor  
Notes:  
1. All dimensions are in millimeters. Angles are in degrees.  
2. The terminal #1 identifier and terminal numbering conform to JESD 95-1 SPP-012.  
3. Contact plating: Electroless NiPdAu  
PCB Mounting Pattern  
Notes:  
1. All dimensions are in millimeters. Angles are in degrees.  
.
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
12 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
Tape and Reel Information Carrier and Cover Tape Dimensions  
Feature  
Measure  
Symbol  
Size (in)  
0.132  
0.132  
0.051  
0.315  
0.079  
0.138  
0.362  
0.315  
Size (mm)  
3.35  
Length  
A0  
B0  
K0  
P1  
P2  
F
Width  
3.35  
Cavity  
Depth  
1.30  
Pitch  
4.00  
Cavity to Perforation - Length Direction  
2.00  
Centerline Distance  
Cavity to Perforation - Width Direction  
3.50  
Cover Tape  
Carrier Tape  
Width  
Width  
C
5.40  
W
8.00  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
13 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
Tape and Reel Information Reel Dimensions  
Standard T/R size = 2500 pieces on a 7” reel.  
Feature  
Measure  
Diameter  
Symbol  
Size (in)  
6.969  
Size (mm)  
177.0  
A
Flange  
Thickness  
W2  
0.559  
14.2  
Space Between Flange  
Outer Diameter  
W1  
N
0.346  
2.283  
0.512  
0.079  
0.787  
8.8  
58.0  
13.0  
2.0  
Arbor Hole Diameter  
Key Slit Width  
C
Hub  
B
Key Slit Diameter  
D
20.0  
Tape and Reel Information Tape Length and Label Placement  
Notes:  
1. Empty part cavities at the trailing and leading ends are sealed with cover tape. See EIA 481-1-A.  
2. Labels are placed on the flange opposite the sprockets in the carrier tape.  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
14 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
Assembly Notes  
Compatible with both lead-free (260°C peak. reflow temp.) and tin/lead (245°C peak. reflow temp.) soldering processes.  
The use of no-clean solder to avoid washing after soldering is recommended.  
Contact plating: Electroless NiPdAu (Plating thickness: Ni 0.4±0.10μm, Pd 0.145±0.035μm, Au 0.095±0.025μm)  
Recommended Soldering Temperature Profile  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
15 of 16  
www.qorvo.com  
QPQ1029  
®
Band 1 and Band 3 Dual Filter  
Handling Precautions  
Parameter  
Rating  
Standard  
ESDꢁ–ꢁHuman Body Model (HBM)  
Class 1C  
ESDAꢀ/ꢀJEDEC JS-001-2012  
JEDEC JESD22-C101F  
IPC/JEDEC J-STD-020  
Caution!  
ESD-Sensitive Device  
ESDꢁ–ꢁCharged Device Model (CDM) Class C3  
MSLꢁ–ꢁMoisture Sensitivity Level  
Level 3  
RoHS Compliance  
This part is compliant with 2011/65/EU RoHS directive (Restrictions on the Use of Certain Hazardous Substances in Electrical and  
Electronic Equipment) as amended by Directive 2015/863/EU.  
This product also has the following attributes:  
Lead Free  
Halogen Free (Chlorine, Bromine)  
Antimony Free  
TBBP-A (C15H12Br402) Free  
PFOS Free  
SVHC Free  
Pb  
Contact Information  
For the latest specifications, additional product information, worldwide sales and distribution locations:  
Web: www.qorvo.com  
Tel: 1-844-890-8163  
Email: customer.support@qorvo.com  
Important Notice  
The information contained herein is believed to be reliable; however, Qorvo makes no warranties regarding the information contained  
herein and assumes no responsibility or liability whatsoever for the use of the information contained herein. All information contained  
herein is subject to change without notice. Customers should obtain and verify the latest relevant information before placing orders for  
Qorvo products. The information contained herein, or any use of such information does not grant, explicitly or implicitly, to any party any  
patent rights, licenses, or any other intellectual property rights, whether with regard to such information itself or anything described by  
such information. THIS INFORMATION DOES NOT CONSTITUTE A WARRANTY WITH RESPECT TO THE PRODUCTS DESCRIBED  
HEREIN, AND QORVO HEREBY DISCLAIMS ANY AND ALL WARRANTIES WITH RESPECT TO SUCH PRODUCTS WHETHER  
EXPRESS OR IMPLIED BY LAW, COURSE OF DEALING, COURSE OF PERFORMANCE, USAGE OF TRADE OR OTHERWISE,  
INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  
Without limiting the generality of the foregoing, Qorvo products are not warranted or authorized for use as critical components in medical,  
lifesaving, or life-sustaining applications, or other applications where a failure would reasonably be expected to cause severe personal  
injury or death.  
Copyright 2019 © Qorvo, Inc. | Qorvo is a registered trademark of Qorvo, Inc.  
Datasheet Rev E, January 10, 2020 | Subject to change without notice  
16 of 16  
www.qorvo.com  

相关型号:

QPQ1029EVB

Band 1 and Band 3 Dual Filter
QORVO

QPQ1029TR7

Band 1 and Band 3 Dual Filter
QORVO

QPQ1031Q

Band 1/3 Multiplexer
QORVO

QPQ1031QEVB

Band 1/3 Multiplexer
QORVO

QPQ1031QPCK

Band 1/3 Multiplexer
QORVO

QPQ1031QSR

Band 1/3 Multiplexer
QORVO

QPQ1031QTR13

Band 1/3 Multiplexer
QORVO

QPQ1060

L1 Low Loss GPS SAW Filter
QORVO

QPQ1060EVB

L1 Low Loss GPS SAW Filter
QORVO

QPQ1060EVB01

L1 Low Loss GPS SAW Filter
QORVO

QPQ1060TR7

L1 Low Loss GPS SAW Filter
QORVO

QPQ1060_V01

L1 Low Loss GPS SAW Filter
QORVO