BP5039-15_10 [ROHM]
Non-Isolated AC/DC Converter; 非隔离式AC / DC转换器![BP5039-15_10](http://pdffile.icpdf.com/pdf1/p00171/img/icpdf/BP503_956379_icpdf.jpg)
型号: | BP5039-15_10 |
厂家: | ![]() |
描述: | Non-Isolated AC/DC Converter |
文件: | 总4页 (文件大小:1020K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Data Sheet
100VAC Input/15VDC (200mA) Output
Non-Isolated AC/DC Converter
BP5039-15
Absolute Maximum Ratings
Dimensions (Unit : mm)
35.0MAX.
9.1MAX.
Parameter
Input voltage
Symbol
Vi
Limits
170
Unit
V
Maximum output current
ESD endurance
IoMAX
Vsurge
Topr
200
mApk
kV
2
1
3
5
7
10
12
Operating temperature range
Storage temperature range
−25 to +80
−25 to +105
°C
°C
0.25±0.05
4.85MAX.
7.62
1.3±0.2
2.54�11=27.94
0.5±0.1
Tstg
5.08
3.6MAX
4.25MAX.
Electrical Characteristics
Parameter
Symbol Min.
Typ.
141
15.00
−
0.05
0.05
0.07
74
Max.
Conditions
DC(80 to 120VAC)
Vi=141V, Io=100mA
Vi=141V
Vi=113 to 170V, Io=100mA
Vi=141V, Io=0 to 100mA
Vi=141V, Io=100mA
Vi=141V, Io=200mA
Vi=170V, Io=200mA
Vi=141V
Unit
V
V
mA
V
V
Vp-p
%
K
mA
mA
Derating Curve
Input voltage range
Output voltage
Output current
Line regulation
Load regulation
Output ripple voltage
Power conversion efficiency
Surface temperature rising
Output current overcurrent1
Output current overcurrent2
113
14.25
0
170
15.75
200
0.20
0.20
0.15
−
−
−
290
Vi
Vo
Io
Derating Curve
250
200
150
∗1
−0.20
−0.20
−
Vr
Vl
Vp
η
100
50
0
Operation Range
∗2
-30-20-10
0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
60
∗2
−
240
−
Tc
Im
Is
38
270
260
Switching Frequency
Switching Frequency
Vi=141V
(Ta=25°C, Vi=141V)
45
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Please refer to Load regulation, Conversion efficiency.
40
35
30
25
20
15
10
5
Application Circuit
Pin No.
Function
1
Output terminal Vo(15V)
BP5039-15
2
Skip
0
0
Be sure to use fuse for safety.
50
100
150
200
3
4
Choke coil connect
Output Current Io(mA)
Skip
5
Choke coil connect
12 10
7 5 3 1
6
Skip
Conversion Efficiency
7
COMMON
DC motor
FUSE
8
Skip
Conversion Efficiency
R1
Ii
Io
C2
D1
9
Skip
(Ta=25°C, Vi=141V)
100
10
11
12
N.C.
L1
+
−
+
−
Skip
C3
C1
Vo
80
60
40
20
0
Vi
Input terminal Vi(141VDC)
ZNR
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
0
50
100
150
200
External Component Specifications
Output Current Io(mA)
FUSE: Fuse
Please make sure to use quick acting fuse (1A)
C1: Input capacitor
Above 250V, 22 to 820µF
Load Regulation
Ripple current 0.13Arms above
Load Regulation
(Ta=25°C, Vi=141V)
C2: Output capacitor
Above 25V, 100 to 470µF, Low impedance
ESR : 0.4Ω Max.
Ripple current 0.25Arms above
16
14
12
10
8
Impedance of capacitor effects the output ripple voltage.
Above 250V, 0.1 to 0.22µF
Use a film or ceramic capacitor.
Evaluate under actual conditions.
C3: Noise reduction
capacitor
6
4
2
0
0
50
100 150 200 250 300
Output Current Io(mA)
L1: Power inductor
D1: Rectifier diode
Inductance : 1mH, Rating current : above 600mA
Choose components that do not easily get magnetically saturated at
high temperature.
Surface Temperature Increase
Use a rectifying diode with a peak reverse voltage of 400V or higher,
an average rectification current of 0.5A or larger and a peak surge
current of 20A or larger. When using a large capacitance input capacitor
select a component strong against inrush current during power up.
Full-wave rectification can be used.
Surface Temperature Increase
(Ta=25°C, Vi=141V)
50
45
40
35
30
25
20
15
10
5
10 to 22Ω, 1/4W
Determine the ideal value through actual testing.
R1: Noise reduction
resistor
ZNR: Varistor
A varistor must be used to protect against lightning surges and static
electricity.
0
0
50
100
150
200
250
Output Current Io(mA)
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
2010.01 - Rev.A
1/1
Notice
N o t e s
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specified in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, office-automation equipment, commu-
nication devices, electronic appliances and amusement devices).
The Products specified in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, fire or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuel-
controller or other safety device). ROHM shall bear no responsibility in any way for use of any
of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
R1010
A
相关型号:
©2020 ICPDF网 联系我们和版权申明