RM4UA33MW [SCHNEIDER]
Power/Signal Relay, DPDT, Momentary, 0.01A (Coil), 12VDC (Coil), 120mW (Coil), 250VDC (Contact), DC Input, Panel Mount;![RM4UA33MW](http://pdffile.icpdf.com/pdf2/p00246/img/icpdf/RM4UA33MW_1495766_icpdf.jpg)
型号: | RM4UA33MW |
厂家: | ![]() |
描述: | Power/Signal Relay, DPDT, Momentary, 0.01A (Coil), 12VDC (Coil), 120mW (Coil), 250VDC (Contact), DC Input, Panel Mount 光电二极管 继电器 |
文件: | 总3页 (文件大小:56K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Product data sheet
Characteristics
RM4UA33MW
voltage measurement relay RM4-U - range
30..500 V - 24..240 V AC DC
Product availability: Stock - Normally stocked in distribution facility
Main
Commercial Status
Commercialised
Range of product
Zelio Control
Product or component
type
Industrial measurement and control relays
Relay type
Voltage measurement relay
RM4U
Relay name
Relay monitored
parameters
Overvoltage or undervoltage detection
Time delay
Adjustable 0.05...30 s
1.5...3.3 VA AC
Power consumption in
VA
Measurement range
50...500 V voltage DC
50...500 V voltage AC 50/60 Hz
30...300 V voltage DC
30...300 V voltage AC 50/60 Hz
Contacts type and
composition
2 C/O
Complementary
[Us] rated supply voltage
24...240 V DC
24...240 V AC 50/60 Hz
Power consumption in W
Output contacts
1.2 W DC
2 C/O
Internal input resistance
1111000 Ohm
11110000 Ohm
668000 Ohm
Permissible continuous overload
Permissible non repetitive overload
400 V
550 V
550 A for <= 1 s
500 A for <= 1 s
Setting accuracy of the switching threshold
Switching threshold drift
+/-5 %
<= 0.5 % within the supply voltage range (0.85...1.1 Un)
<= 0.06 % per degree centigrade depending permissible ambient air temperature
Setting accuracy of time delay
Time delay drift
10 P
<= 0.5 % within the supply voltage range (0.85...1.1 Un)
<= 0.07 % per degree centigrade depending on the rated operational temperature
Hysteresis
Marking
5...30 % adjustable of voltage threshold setting
CE : EMC 89/336/EEC
CE : LVD 73/23/EEC
Overvoltage category
[Ui] rated insulation voltage
Control circuit voltage limits
Supply frequency
III conforming to IEC 60664-1
500 V conforming to IEC
0.85...1.1 Uc
50/60 Hz +/- 5 %
Supply disconnection value
Operating position
> 0.1 Uc
Any position without derating
Connections - terminals
Screw terminals 2 x 2.5 mm², flexible cable without cable end
Screw terminals 2 x 1.5 mm², flexible cable with cable end
Tightening torque
5.31...9.73 lbf.in (0.6...1.1 N.m)
<= 30000000 cycles
8 A
Mechanical durability
[Ith] conventional free air thermal current
Mar 13, 2014
1
[Ie] rated operational current
0.3 A at 115 V DC-13 158 °F (70 °C) conforming to VDE 0660
0.3 A at 115 V DC-13 158 °F (70 °C) conforming to IEC 60947-5-1/1991
0.1 A at 250 V DC-13 158 °F (70 °C) conforming to VDE 0660
0.1 A at 250 V DC-13 158 °F (70 °C) conforming to IEC 60947-5-1/1991
3 A at 250 V AC-15 158 °F (70 °C) conforming to VDE 0660
3 A at 250 V AC-15 158 °F (70 °C) conforming to IEC 60947-5-1/1991
3 A at 24 V AC-15 158 °F (70 °C) conforming to VDE 0660
3 A at 24 V AC-15 158 °F (70 °C) conforming to IEC 60947-5-1/1991
3 A at 115 V AC-15 158 °F (70 °C) conforming to VDE 0660
3 A at 115 V AC-15 158 °F (70 °C) conforming to IEC 60947-5-1/1991
2 A at 24 V DC-13 158 °F (70 °C) conforming to VDE 0660
2 A at 24 V DC-13 158 °F (70 °C) conforming to IEC 60947-5-1/1991
Switching capacity in mA
Switching voltage
10 mA at 12 V
250 V AC
<= 440 V AC
Contacts material
Number of cables
Height
90/10 silver nickel contacts
2
3.07 in (78 mm)
0.89 in (22.5 mm)
3.15 in (80 mm)
Width
Depth
Terminals description ISO n°1
(15-16-18)OC
(25-26-28)OC
(A1-A2)CO
(C-B2-B3)CO
Output relay state
9 mm pitches
Tripped if A measured > A set
2.5
Product weight
0.37 lb(US) (0.168 kg)
Environment
Standards
EN/IEC 60255-6
Product certifications
CSA
GL
UL
Ambient air temperature for storage
Ambient air temperature for operation
Relative humidity
-40...185 °F (-40...85 °C)
-4...149 °F (-20...65 °C)
15...85 % 3K3 conforming to IEC 60721-3-3
0.35 ms (f = 10...55 Hz) conforming to IEC 60068-2-6
15 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance
Shock resistance
IP degree of protection
IP50 (casing) conforming to IEC 60529
IP20(Terminals) conforming to IEC 60529
Pollution degree
3 conforming to IEC 60664-1
Dielectric test voltage
2.5 kV
4.8 kV
Non-dissipating shock wave
Resistance to electrostatic discharge
8 kV air conforming to IEC 61000-4-2 level 3
6 kV contact conforming to IEC 61000-4-2 level 3
Resistance to electromagnetic fields
Resistance to fast transients
9.14 V/yd (10 V/m) conforming to IEC 61000-4-3 level 3
2 kV conforming to IEC 61000-4-4 level 3
Protection against electric shocks
Disturbance radiated/conducted
2 kV conforming to IEC 61000-4-5 level 3
CISPR 11 group 1 - class A
CISPR 22 - class A
Ordering and shipping details
Category
22376 - RELAYS-MEASUREMENT(RM4)
Discount Schedule
GTIN
CP2
00785901481720
Nbr. of units in pkg.
Package weight(Lbs)
Product availability
Returnability
1
0.33
Stock - Normally stocked in distribution facility
Y
Country of origin
ID
2
Contractual warranty
Period
18 months
3
相关型号:
©2020 ICPDF网 联系我们和版权申明