GLC50 Commercial/GLM50 Medical  
50 WATT GLOBAL PERFORMANCE SWITCHERS  
GLOBAL PERFORMANCE SWITCHERS  
Features:  
D C P o w e r S u p p l i e s  
• Cost-effective power source  
• Universal input 90-264 Vac  
• 2-year warranty  
• Compact (4.25” x 2.50” x 1.25”; meets  
1U applications)  
• Overload and overvoltage protection  
• Conducted EMI exceeds FCC Class B and  
CISPR 22 Class B (Commercial models) and  
CISPR 11 Class B (Medical models)  
• Commercial UL/CSA/IEC60950-1, EN60950 approvals  
• Medical UL/EN/IEC60601-1, CSA22.2 No. 601,  
• RoHS compliant models available (G suffix)  
marked to LVD  
SPECIFICATIONS  
Ac Input  
Temperature Coefficient  
0.03%/°C typical on all outputs.  
90-264 Vac, 47-63 Hz single phase..  
Input Current  
Output Noise  
Maximum input current at 120 Vac, 60 Hz with full rated output load: 1.5 A  
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise  
probe directly across output terminals of the power supply.  
Hold-Up Time  
15 ms minimum from loss of ac input at full load, nominal line (115 Vac).  
Transient Response  
500 μs typical response time for return to within 0.5% of final value for a 50% load  
step change. ∆i/∆t<0.2 A/μs. Maximum voltage deviation is 3.5%. Startup/shut-  
down overshoot less than 3%.  
Output Power  
50 W continuous, 60 W peak. Peak ratings are for 60 s maximum duration,  
10% duty cycle. During peak load condition, output regulation may exceed  
total regulation limits.  
Voltage Adjustment  
Built-in potentiometer adjusts V1 5%.  
Output Regulation  
To maintain specified regulation on multi-output models, output #1 load  
power must be at least 1/5th of, and not greater than 5 times output #2 load  
power.  
EMI/EMC Compliance  
All models include built-in EMI filtering to meet the following emissions require-  
ments:  
Overload Protection  
EMI SPECIFICATIONS  
COMPLIANCE LEVEL  
Fully protected against short circuit and output overload. Short circuit pro-  
tection is cycling type power limit on outputs 1 & 2; foldback type on output  
3. Recovery after fault is automatic. See output ratings chart for additional  
notes or conditions.  
Conducted Emissions GLC  
Conducted Emissions GLM  
Static Discharge  
RF Field Susceptibility  
Fast Transients/Bursts  
Surge Susceptibility  
EN55022 Class B; FCC Class B  
EN55011 Class B; FCC Class B  
EN61000-4-2, 6 kV contact, 8 kV air  
EN61000-4-3, 3 V/meter  
EN61000-4-4, 2 kV, 5 kHz  
EN61000-4-5, 1 kV diff., 2 kV com.  
Efficiency  
70-85% at full rated load, nominal input voltage, depending on model and  
load distribution.  
Minimum Load  
Commercial Leakage Current  
Operating without minimum load will not degrade reliability, but regula-  
tion may be affected. Multiple output models require 20% minimum load  
on V1 for proper regulation. Single models require 5% minimum load when  
a transient load greater than 30% is applied or removed, but will operate  
without load.  
160 μA 254 Vac @ 60 Hz input (with no deviations).  
Commercial Safety  
All GLC models are approved to UL1950, CSA22.2 No.  
234 Level 3, IEC950 and EN60950.  
Medical Leakage Current  
100 μA 264 Vac @ 60 Hz input (normal conditions).  
Input Protection  
Internal ac fuse provided. Designed to blow only if a catastrophic failure oc-  
curs in the unit—fuse does not blow on overload or short circuit.  
Medical Safety  
Inrush is limited by internal thermistors. Inrush at 240 Vac,  
averaged over the first ac half-cycle under cold start  
conditions will not exceed 37 A.  
All GLM50 models are approved to UL/EN/IEC60601-1, CSA22.2 No. 601.  
All specifications are typical at nominal input, full load at 25OC unless otherwise stated  
Commercial  
Model  
Medical  
Model  
Minimum  
Load (B)  
Total  
Regulation (A)  
Output No.  
Output  
+5.05 V  
+12 V  
-12 V  
+5.05 V  
+15 V  
-15 V  
+5.05 V  
+24 V  
-12 V  
+3.3 V  
+12 V  
-12 V  
3.3 V  
Current  
4 A  
OVP Setpoint  
6.2 0.6 V  
Noise P-P  
50 mV  
GLC50A  
GLC50B  
GLC50D  
GLC50G  
GLM50A  
GLM50B  
GLM50 D  
GLM50G  
1
2
3
1
2
3
1
2
3
1
2
3
1
1
1
1
1
1
1
0.8 A  
0.8 A  
0.8 A  
0.8 A  
2%  
+10%,-5%  
3%  
2.5 A  
0.2 A  
4 A  
120 mV  
120 mV  
50 mV  
6.2 0.6 V  
6.2 0.6 V  
4.2 0.6 V  
2%  
2.5 A  
0.2 A  
4 A  
150 mV  
150 mV  
50 mV  
+10%,-5%  
3%  
2%  
1.5 A  
0.2 A  
4 A  
240 mV  
120 mV  
33 mV  
+10%,-5%  
3%  
2%  
2.5 A  
0.2 A  
8 A  
120 mV  
120 mV  
66 mV  
+10%-5%  
3%  
GLC50-3.3  
GLC50-5  
GLM50-3.3  
GLM50-5  
0.2  
0.4  
4.2 0.6 V  
6.2 0.6 V  
14 1.1 V  
18.5 1.5 V  
28 2.5 V  
34.5 2.8 V  
54 3.0 V  
2%  
5.1 V  
8 A  
75 mV  
2%  
GLC50-12  
GLC50-15  
GLC50-24  
GLC50-28  
GLC50-48  
Notes:  
GLM50-12  
GLM50-15  
GLM50-24  
GLM50-28  
GLM50-48  
12 V  
4.2 A  
3.3 A  
2.1 A  
1.8 A  
1.1 A  
0.2  
120 mV  
150 mV  
240 mV  
280 mV  
480 mV  
2%  
15 V  
0.16  
0.1  
2%  
24 V  
2%  
28 V  
0.09  
0.05  
2%  
48 V  
2%  
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.  
B. To maintain specified regulation on multi-output models, output #1 load power must be at least 1/5th of, and not greater than 5 times output #2 load power.  
C. Add “Gsuffix to model number for RoHS compliant model.  
GLC50 MECHANICAL SPECIFICATIONS  
ENVIRONMENTAL SPECIFICATIONS OPERATING  
NON-OPERATING  
-40 to +85°C  
0 to 95% RH  
40 gpk  
Temperature (A)  
Humidity (A)  
Shock (B)  
0 TO 50°C  
A. Units should be allowed to warm up/operate under non-condensing condi-  
tions before application of power. derate output current and total output  
power by 2.5% per °C above 50°C.  
0 to 95% RH  
20 gpk  
B. Shock testing—half-sinusoidal, 10 3 ms duration, direction, 3 orthogonal  
axes, total 6 shocks.  
Altitude  
-500 to 10,000 ft  
-500 to 40,000 ft  
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3  
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.  
Vibration (C)  
1.5 g rms0.003 g2/Hz 5 g rms0.026 g2/Hz  
SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com. Rev. 1/07.  
Data Sheet © 2007 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.  
However, Condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.  

相关型号:

GLC50-12

AC-DC Regulated Power Supply Module, 50W
SLPOWER

GLC50-15

50 WATT GLOBAL PERFORMANCE SWITCHERS
SLPOWER

GLC50-24

50 WATT GLOBAL PERFORMANCE SWITCHERS
SLPOWER

GLC50-28

Power Supply Module
SLPOWER

GLC50-3.3

Power Supply Module
SLPOWER

GLC50-48

AC-DC Regulated Power Supply Module, 50W
SLPOWER

GLC50-5

AC-DC Regulated Power Supply Module, 50W
SLPOWER

GLC50A

50 WATT GLOBAL PERFORMANCE SWITCHERS
SLPOWER

GLC50AG

GLC50 Commercial/GLM50 Medical
ETC

GLC50B

50 WATT GLOBAL PERFORMANCE SWITCHERS
SLPOWER

GLC50D

INSTALLATION INSTRUCTIONS GLC50 MULTI OUTPUT SERIES
SLPOWER

GLC50G

50 WATT GLOBAL PERFORMANCE SWITCHERS
SLPOWER