GLM65H [SLPOWER]

AC-DC Regulated Power Supply Module, 65W;
GLM65H
型号: GLM65H
厂家: SL Power Electronics    SL Power Electronics
描述:

AC-DC Regulated Power Supply Module, 65W

输出元件
文件: 总2页 (文件大小:226K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
GLC65 Commercial/GLM65 Medical  
65 Watt Multiple Output Global Performance Switchers  
FEATURES:  
65 Watt Wide Range Input  
High Efficiency (Up to 90%)  
Universal input 90-264 Vac  
2-year warranty  
Also available in single outputs  
Conducted EMI exceeds FCC Class B and CISPR 22  
Class B (Commercial models) and CISPR 11 Class B  
(Medical models)  
Exempt from line harmonics standard EN61000-3-2  
Commercial Approved to UL1950, CSA-C22.2 No. 950,  
EN60950  
Medical Approved to UL2601-1, CSA 22.2 No. 601.1,  
and EN60601-1  
marked to LVD  
SPECIFICATIONS:  
Ac Input  
90-264 Vac, 47-63 Hz single phase  
Minimum Load  
Output Power  
No minimum load required on any output. However,  
regulation limits may be exceeded if extreme conditions  
are applied. Contact factory for assistance.  
Total continuous output power is 60 W, 75 W peak for 60 s  
10% duty cycle. Total continuous rating with 150 LFM of  
air is 70 W.  
Temperature Coefficient: 0.03%°C typical on all outputs.  
Input Current  
Units are exempt from input current harmonic require-  
ments of EN61000-3-2 when output power is less than  
62W. Maximum input current at minimum input voltage  
and output overload will be less than 2.0 A.  
Voltage Adjustment  
Units provided with potentiometer capable of a minimum  
adjustment range of +/- 5% from nominal setting.  
EMI / EMC Compliance:  
Inrush Current  
All models include built-in EMI filtering to meet the EMC  
requirements of IEC601-1-2.  
Inrush is limited by internal thermistor. The inrush at 240  
Vac, averaged over the first ac half-cycle under cold start  
conditions will not exceed 37 A.  
Performance  
EMC Standard  
Conducted Emissions GLC65 EN55022, Class B; FCC Class B  
Conducted Emissions GLM65 EN55011, Class B; FCC Class B  
Static Discharge  
RF Field Susceptibility  
Fast Transients / Bursts  
Surge Susceptibility  
Input Protection  
EN61000-4-2, Level 3  
EN61000-4-3, Level 3  
EN61000-4-4, Level 3  
EN61000-4-5, Level 3  
Internal AC fuse provided on all units. Designed to blow  
only if a catastrophic failure occurs in the unit -- Fuse  
does not blow on short circuit or unsustained overload.  
Conducted RF Susceptibility EN61000-4-6, 3V, 80%  
HoldupTime  
Voltage Sags & Surges  
EN61000-4-11  
Output voltage stays within regulation for 20 ms from loss  
of ac input at 65 W load, from 120 Vac input.  
Line Frequency Harmonics  
EN61000-3-2 Class A (>62Wout)  
Exempt (<62Wout)  
GLC65 Commercial - Safety  
Efficiency  
Condor DC Power Supplies, Inc. declares under our sole  
responsibility that all models are in conformity with the  
applicable requirements of EN60950 following the  
provisions of the Low Voltage Directive 73/23/EEC. All  
models are approved to UL1950 (with no D3 deviations),  
CSA22.2 No. 950-95 3rd edition, Level 3, IEC950,  
EN60950. CB certificate available.  
80% typical.  
Overload Protection  
Fully protected against short circuit and output overload.  
Short circuit protection is cycling type power limit and will  
automatically recover after removal of fault.  
Overvoltage Protection  
Built in with firing point set. OVP firing reduces output to  
less than 50% of nominal voltage in less than 50 ms.  
Commercial Leakage Current  
Less then 500 µA @ 120 Vac. Less then 1.2 mA @ 240 Vac.  
GLM65 Medical - Safety  
Output Noise  
Approvals: All models are certified to be in compliance  
with the applicable requirements of UL2601-1, CSA 22.2  
No. 601.1, IEC 601-1 (1988), EN 60601-1: 1990.  
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential  
mode. Measured with scope probe directly across output  
terminals of the power supply with load terminated with  
1µF capacitor.  
Medical Leakage Current  
40 µA under normal conditions (132 Vac @ 60 Hz).  
Maximum under single fault conditions (264 Vac @ 60  
Hz) is 170 µA.  
Transient Response  
Main Output - 500 µs typical response time for return to  
within 0.5% of final value for a 50% load step within the  
regulation limits of minimum and maximum load, i/t<  
0.2 A/µs. Maximum voltage deviation is 3.5%.  
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033  
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com  
38  
GLC65 Commercial/GLM65 Medical 65 Watt Multipe Output  
Output  
Commercial  
Model  
Medical  
Model  
Output  
Total  
V1 Adjustment  
Note (C)  
OVP  
Ripple/  
Noise  
Output No. Output  
Maximum  
(B)  
Maximum (A)  
Regulation (E)  
Setpoint  
GLC65A  
GLC65B  
GLC65D  
GLM65A  
GLM65B  
GLD65D  
1
2
3
1
2
3
1
2
+5.0 V  
+12 V  
-12 V  
7 A  
3 A  
9 A  
5 A  
2%  
5%  
6%  
2%  
4%  
5%  
2%  
3%  
6.2 ± 0.6 V  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
± 5%  
--  
--  
2.5 A  
7 A  
4 A  
--  
--  
+5.1 V  
+15 V  
-15 V  
9 A  
6.2 ± 0.6 V  
± 5%  
--  
2.5 A  
2 A  
4 A  
--  
3 A  
--  
--  
6.2 ± 0.6 V  
--  
+5.0 V  
+24 V  
7 A  
9 A  
± 5%  
--  
1.5 A  
2.5 A  
3
1
2
3
1
2
3
1
2
3
-12 V  
+5.0 V  
+24 V  
+12 V  
+5.0 V  
+3.3 V  
+12 V  
+3.3 V  
+5.0 V  
+12 V  
2.5 A  
7 A  
4 A  
9 A  
2.5 A  
4 A  
8 A  
5 A  
4 A  
8 A  
6 A  
3 A  
6%  
2%  
--  
--  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
GLC65E  
GLC65G  
GLC65H  
GLM65E  
GLM65G  
GLM65H  
6.2 ± 0.6 V  
± 5%  
--  
1.5 A  
2.5 A  
5 A  
3%  
--  
6%  
--  
--  
3%  
6.2 ± 0.6 V  
± 5%  
--  
4 A  
3%  
--  
2.5 A  
5 A  
6%  
--  
--  
3.5%  
4.5%  
6%  
4.3 ± .8V  
± 5%  
--  
4 A  
--  
--  
2.5 A  
--  
Notes:  
A. Continuous individual output ratings for unrestricted convection cooling. Combination of individual output loads must not exceed total power rating.  
B. Peak rating for 60 s 10% duty cycle or continuous rating 150 LFM forced air cooling.  
C. Adjustment on V1 varies all outputs simultaneously (1% on V1 @ 1% on V2 & V3).  
D. Total combined current of V1 &V2 not to exceed 12 A.Combination of individual output loads must  
not exceed total power rating.  
E. Total regulation is defined as maximum deviation from the initial set point.With all other outputs at 50% load, output under test can be varied from 0 to 100% load and varied to  
any ac line voltage. Initial set point is 1% on V1, 2% on V2 and 3% on V3  
GLC65/GLM65 MECHANICAL SPECIFICATIONS  
J1 INPUT:  
AMP P/N 640445-3, .156 [3.96mm] CTR,  
.045 [1.14mm] Square pin header  
PIN 3) Ac Neutral  
PIN 2) No Pin  
PIN 1) Ac Line  
J2 OUTPUT: AMP P/N 640445-6, .156 [3.96MM] CTR  
.045 [1.14MM] Square pin header  
PIN 1) Output #2  
PIN 2) Output #1  
PIN 3) Output #1  
PIN 4) Common  
PIN 5) Common  
PIN 6) Output #3  
GROUND: .250 X 0.32 FastonTab  
MATING CONNECTORS: AMP P/N  
AMP  
HOUSING CONTACTS  
INPUT  
OUTPUT  
640250-3  
640250-6  
770476-1  
770476-1  
WEIGHT: 6.5 OZ. [.182 KG]  
OPTIONAL CHASSIS/COVER KIT: P/N 08-30466-0065  
NOTE:  
5 A Maximum recommended current per connector pin  
convection, 7A with air.  
A. Units should be allowed to warm up/operate under non-condensing conditions  
Environmental  
Specification  
Operating  
Non-operating  
before application of power. Derate output current and total output power by 2.5%  
per °C above 50°C. Derate output power and current on all outputs by 2.5 % per °C  
For operation in a confined space, moving air may be required. Under all  
conditions, the cooling vs. load profile should be such that heat sinks and/or  
heatsink temperatures do not exceed 90 °C for extended periods.  
B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3  
orthogonal axes.Tested for 10 min./axis operating and 1 hr./axis non-operating.  
C. Shock testinghalf-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,  
total 6 shocks.  
Temperature (A)  
Humidity (A)  
Shock (B)  
0 to 50oC  
0 to 95% RH  
20 gpk  
-40 to +85oC  
0 to 95% RH  
40 gpk  
Altitude  
-500 to 10,000 ft  
1.5 grms, 0.003 g2/Hz  
-500 to 40,000 ft  
5 grms, 0.026 g2/Hz  
Vibration (C)  
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033  
800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com  
39  

相关型号:

GLM75

75 Watt Multiple Output Global Performance Switchers
SLPOWER

GLM75-12

Power Supply Module
SLPOWER

GLM75-15

75 Watt Single Output Global Performance Switchers
ETC

GLM75-24

75 Watt Single Output Global Performance Switchers
ETC

GLM75-24G

75 Watt Single Output Global Performance Switchers
ETC

GLM75-28

75 Watt Single Output Global Performance Switchers
ETC

GLM75-5

75 Watt Single Output Global Performance Switchers
ETC

GLM75A

75 Watt Multiple Output Global Performance Switchers
SLPOWER

GLM75B

75 Watt Multiple Output Global Performance Switchers
SLPOWER

GLM75C

75 Watt Multiple Output Global Performance Switchers
SLPOWER

GLM75D

AC-DC Regulated Power Supply Module, 75W
SLPOWER

GLM75E

75 Watt Multiple Output Global Performance Switchers
SLPOWER