Technical  
Specification  
500 W Triple Vout Series  
Industrial Grade AC/DC Power Supply With PFC  
85-264 Vrms  
12/24/36/48 V  
500 W  
700 W  
Up to 90 %  
Input Voltage  
Semi-Regulated Output  
Output Continuous Output Transient Full Load Efficiency  
Includes 5 V (10 W) and 12 V (50 W) “Always On” Standby Power Outputs  
1500 W Encased  
1000 W Encased  
Package Configurations Available  
to three units can be factory mounted into a chassis.  
The 500 W Triple Vout Series can be configured as follows:  
500 W Encased  
500ꢀWꢀ(1ꢀunit)ꢀ  
•ꢀ1000ꢀWꢀ(2ꢀunits)ꢀ  
1500ꢀWꢀ(3ꢀunits)  
Product Features  
• High efficiency (90% for 48 VOUT Model at 500 W)  
• Universal input voltage range  
• DC Power Good / AC Power Good signals  
• Remote enable input  
• Semi-regulated output for bus stability  
• Parallel operation supported  
• Fan status output / Fan enable input  
• Small size: 3.59" x 5.25" x 1.63"  
• RoHS 6/6 compliant  
• Integral fan cooling with speed control  
• Active PFC; EN61000-3-2 compliant  
• 5 V (10 W) and 12 V (50 W) standby outputs  
• Low noise; EN55011 / EN55022 Class B compliant  
• Over–current, over–voltage, and over–temp protection  
Product # AQ0500IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005055 Rev. D  
08/24/15  
Page 1  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 500 W  
Grade: Industrial  
Technical Specification  
ACuQor 500W Triple Vout Series Electrical Characteristics  
All specifications typical with TA = 25 °C, unless otherwise specified. Specifications subject to change without notice.  
GENERAL SPECIFICATIONS  
MAIN OUTPUT SPECIFICATIONS  
Output power (continuous) 85-132/170-264 Vrms  
Fundamental ripple freq.  
Input  
Output  
500 kHz  
250 kHz  
39 dBA @ 1 m max.  
500 W (Note 1)  
700 W (Note 1)  
See Figures 11, 12  
(5 s transient)  
85-132/170-264 Vrms  
132-170 Vrms  
Audible noise  
Weight  
Fan speed varies with temp.  
(EC)  
(RC)  
(TC)  
540 g (19.1 oz)  
1068 g (37.7 oz)  
1582 g (55.8 oz)  
Nominal DC output  
voltage (at 250W)  
(Semi-regulated)  
12 Vout (model 1T)  
24 Vout (model 2T)  
36 Vout (model 3T)  
48 Vout (model 4T)  
12.4 V  
25 V  
37.5 V  
50 V  
MTBF  
MIL-217  
343.6 kHours  
TBD kHours  
Demonstrated  
Efficiency  
(see figs. 1, 3, 5, 7)  
(see Note 1)  
12 Vout, 115 Vrms, 500 W  
48 Vout, 115 Vrms, 500 W  
12 Vout, 230 Vrms, 500 W  
48 Vout, 230 Vrms, 500 W  
86% typ.  
89% typ.  
88% typ.  
90% typ.  
ISOLATION SPECIFICATIONS  
Isolation voltage  
Input to output  
Input to ground  
Output to ground  
3000 Vrms  
1500 Vrms  
500 Vrms  
Hold-up time (to -20%)  
(see Note 1)  
12 Vout  
24 / 36 / 48 Vout  
12 ms @ 500 W  
16 ms @ 500 W  
Maximum load capacitance 12 Vout  
16,000 µF  
8,000 µF  
4,000 µF  
2,000 µF  
Insulation resistance  
Leakage currents  
Output to ground  
10 MΩ min.  
24 Vout  
36 Vout  
48 Vout  
See Note 2  
ENVIRONMENTAL CHARACTERISTICS  
Thermal performance  
Operating ambient (see Figure 2)  
Non-operating ambient  
-40 ºC to +70 ºC  
-40 ºC to +85 ºC  
Output ripple voltage  
Switching frequency (20 MHz BW)  
Twice line frequency (at 300 W)  
0.5% p-p  
5.0% p-p  
Relative humidity  
Altitude  
Non-condensing  
5-95% RH  
Turn-on delay  
2 s max.  
Operating  
Non-operating  
5-500 Hz  
10,000 ft max.  
30,000 ft max.  
Transient response  
Iout steps from 50-75%  
At 0.2 A/µs  
Cyclic restart  
3% typ / 6% max. dev.  
100 ms recovery  
Random vibration  
Shock  
0.03 g2/Hz  
Overvoltage protection  
Short circuit protection  
Total regulation  
110-120%  
115% rated Iout  
±6.0%  
Half-sine, 10 ms, 3 axes  
20 g peak  
Cyclic operation  
EMC CHARACTERISTICS  
Conducted emissions  
Over line, load and temperature  
EN55011 and EN55022, FCC  
part15  
Level B  
12V_STANDBY cross-reg. ΔVout caused by 50 W step  
0.5%  
Line frequency harmonics EN61000-3-2  
Class A  
Clause 5b  
Level 3  
Level 3  
Level 3  
Level 3  
Level 3  
Level 3  
3 A/m  
ΔVout caused by 10 W step  
5V_STANDBY cross-reg.  
Thermal protection  
REMOTE_ENABLE  
0.1%  
Voltage fluctuations  
ESD air  
EN61000-3-3  
EN61000-4-2  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
EN61000-4-8  
EN61000-4-11  
Automatic recovery  
+125 ºC (PCB Temp)  
Input Low Voltage  
Input High Voltage  
0.45 V (max)  
4.15 V (min)  
ESD contact  
Radiated immunity  
Fast transients  
12V_STANDBY OUTPUT SPECIFICATIONS  
Output power 85-264 Vrms  
Nominal DC output voltage Semi-regulated  
50 W  
12.4 V  
Line surge immunity  
Conducted immunity  
Power freq. mag. field  
Voltage dip immunity  
Total regulation  
Over line, load and temperature  
±6.0%  
400 mV  
Main output cross-reg.  
Δ12V_STANDBY caused by Δ350W  
on main output  
Switching frequency (20 MHz BW)  
Twice line frequency  
Perf Criteria A, A, B  
<5% UT 10 ms,  
70% UT 500 ms,  
40% UT 100 ms  
Output ripple  
10 mV  
0.45 Vrms  
Output current  
Continuous  
4.2 A  
5.0 A  
NOTES:  
Short circuit protection  
Maximum load capacitance  
Cyclic operation  
1.Main output power rating always includes 5 V and 12 V standby outputs.  
2. Leakage currents see page 5.  
2,000 uF  
5V_STANDBY OUTPUT SPECIFICATIONS  
Output power 85-264 Vrms  
Nominal DC output voltage Fully regulated  
10 W  
5.0 V  
Total regulation  
Over line, load and temperature  
±5.0%  
2.0 A  
Output current  
Continuous  
Short circuit protection  
Maximum load capacitance  
Cyclic operation  
2.5 A  
1,000 uF  
INPUT SPECIFICATIONS  
AC input voltage  
Universal range  
85-264 Vrms  
47-63 Hz  
Input frequency  
Input current  
(see Note 1)  
115 Vrms @ 500 W  
230 Vrms @ 500 W  
5 Arms  
2.5 Arms  
Power factor  
>0.98  
40 A max.  
10.0 A  
Input surge current  
Internal input fuses  
264 Vrms (cold start)  
Both AC lines  
Product # AQ0500IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005055 Rev. D  
08/24/15  
Page 2  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 500 W  
Grade: Industrial  
Technical Specification  
EFFICIENCY, DERATING, AND VOUT DROOP CURVES  
100  
13.5  
13.0  
12.5  
12.0  
11.5  
11.0  
10.5  
95  
90  
85  
80  
75  
70  
65  
Continuous  
115 Vrms  
230 Vrms  
44  
50  
0
6
12  
18  
24  
30  
36  
42  
48  
54  
60  
0
100  
200  
300  
400  
500  
600  
700  
Output Load (A)  
Output Power (W)  
Figure 1: 12 VOUT efficiency curves.  
Figure 2: 12 VOUT droop characteristic.  
100  
95  
90  
85  
80  
75  
70  
65  
27  
26  
25  
24  
Continuous  
23  
22  
21  
115 Vrms  
230 Vrms  
22  
25  
0
100  
200  
300  
400  
500  
600  
700  
0
6
12  
18  
24  
30  
Output Load (A)  
Output Power (W)  
Figure 3: 24 VOUT efficiency curves.  
Figure 4: 24 VOUT droop characteristic.  
100  
95  
90  
85  
80  
75  
70  
65  
40.5  
39.0  
37.5  
36.0  
Continuous  
34.5  
33.0  
31.5  
115 Vrms  
230 Vrms  
16.5  
18.75  
0
3
6
9
12  
15  
18  
21  
0
100  
200  
300  
400  
500  
600  
700  
Output Load (A)  
Output Power (W)  
Figure 5: 36 VOUT efficiency curves.  
Figure 6: 36 VOUT droop characteristic.  
Product # AQ0500IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005055 Rev. D  
08/24/15  
Page 3  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 500 W  
Grade: Industrial  
Technical Specification  
EFFICIENCY, DERATING, AND VOUT DROOP CURVES  
54  
52  
50  
48  
46  
44  
42  
100  
95  
90  
85  
80  
75  
70  
65  
Continuous  
115 Vrms  
230 Vrms  
11  
12.5  
0
100  
200  
300  
400  
500  
600  
700  
0
3
6
9
12  
15  
Output Power (W)  
Output Load (A)  
Figure 7: 48 VOUT efficiency curves.  
Figure 8: 48 VOUT droop characteristic.  
600  
500  
400  
300  
200  
600  
500  
400  
300  
200  
24 / 36 / 48 V, VIN≥ 105 Vrms  
12 V, VIN≥ 105 Vrms  
24 / 36 / 48 V with Fan Enabled  
12 V with Fan Enabled  
100  
100  
0
24 / 36 / 48 V, VIN = 85 Vrms  
12 V, VIN = 85 Vrms  
0
0
10  
20  
30  
40  
50  
60  
70  
80  
0
10  
20  
30  
40  
50  
60  
70  
80  
Case Temperature (ºC)  
Ambient / Case Temperature (ºC)  
Figure 9: Continuous power derating curve in natural convection.  
Figure 10: Fan Disabled continuous power derating curve in natural  
For Fan Disabled, see Figure 10  
convection  
800  
700  
600  
500  
400  
300  
800  
700  
600  
500  
400  
300  
200  
200  
Transient (24/36/48 V Out)  
Transient (12 V Out)  
100  
100  
0
Continuous (24/36/48 V Out)  
Continuous (12 V Out)  
0
132 150  
264  
85  
132  
264  
85  
105  
170  
210  
170  
InputAC Voltage (VRMS  
)
InputAC Voltage (VRMS  
)
Figure 11: Rated output power vs Input AC Voltage.  
Figure 12: Rated output power vs Input AC Voltage.  
Product # AQ0500IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005055 Rev. D  
08/24/15  
Page 4  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 500 W  
Grade: Industrial  
Technical Specification  
Leakage Currents  
AC Leakage Current  
AC Line Connection  
from Input to Earth  
Normal Open Neutral  
Condition  
Fault  
240 V L-N, 1 phase  
400 µA  
800 µA  
ACuQor Typical at  
110% nominal input 208 V L-L, 120 V L-N, 1 of 3 phases  
200 µA  
200 µA  
400 µA  
400 µA  
voltage 60 Hz  
240 V L-N-L, 120 V L-N, split phase  
Standard Testing Certifications  
SAFETY AGENCY CERTIFICATIONS  
CAN/CSA-C22.2 No. 60950-1:2007  
UL 60950-1:2007  
EN 60950-1/A1:2010  
CE Marked  
Product # AQ0500IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005055 Rev. D  
08/24/15  
Page 5  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 500 W  
Grade: Industrial  
CONNECTOR DETAILS  
OUTPUT CONNECTOR PINOUT (top side)  
Pin 1 FAN_GOOD  
Open collector with internal 5V pullup. See Figure A.  
Pulsed low on fan failure, 100ms, 50% duty.  
Short to VOUT(-) to disable fan.  
Pin 2 AC_POWER_GOOD  
Pin 3 DC_POWER_GOOD  
Open collector with internal 5V pullup. See Figure B.  
Pulled low on AC power dropout.  
Open collector with internal 5V pullup. See Figure B.  
Pulled low during startup ramp and within 5 ºC of  
temperature shutdown threshold.  
Pin 4 5V_STANDBY  
Pin 5 VOUT(+)  
Pin 6 VOUT(+)  
Pin 7 VOUT(+)  
Pin 8 VOUT(+)  
Pin 9 Reserved  
Pin 10 Reserved  
Pin 11 REMOTE_ENABLE  
5 V @ 10 W available whenever AC power is applied.  
Positive Output Voltage.  
Figure A: Fan status output / Fan enable input interface circuitry.  
Positive Output Voltage.  
Positive Output Voltage.  
Positive Output Voltage.  
Reserved for future use.  
5V_STANDBY  
Reserved for future use.  
Logic input. See Figure C.  
Pull high to enable main output.  
N4148  
Pin 12 12V_STANDBY  
Pin 13 VOUT(–)  
Pin 14 VOUT(–)  
Pin 15 VOUT(–)  
Pin 16 VOUT(–)  
12 V @ 50 W available whenever AC power is applied.  
Negative Output Voltage.  
5 k  
Negative Output Voltage.  
10 Ohms  
AC_POWER_GOOD or  
DC_POWER_GOOD  
Negative Output Voltage.  
N3904  
From AC/DC  
Monitor  
Negative Output Voltage.  
0.1 µF  
Circuitry  
VOUT(-)  
Figure B: Power good interface circuitry.  
12 V OUTPUT CONNECTOR PINOUT (bottom side)  
Pin 1 VOUT(+)  
Pin 2 VOUT(+)  
Pin 3 VOUT(+)  
Positive Output Voltage.  
Positive Output Voltage.  
Positive Output Voltage.  
Positive Output Voltage.  
Negative Output Voltage.  
Negative Output Voltage.  
Negative Output Voltage.  
Negative Output Voltage  
5V_STANDBY  
5V_STANDBY  
VOUT(+)  
Pin 4  
Pin 5 VOUT(–)  
Pin 6 VOUT(–)  
Pin 7 VOUT(–)  
Pin 8 VOUT(–)  
10 Ohms  
5 k  
To Enable  
Circuitry  
REMOTE_ENABLE  
0.1 µF  
10k  
VOUT(-)  
Figure C: Remote enable interface circuitry.  
MATING CONNECTORS  
Connector  
Type  
Contact  
INDIVIDUAL INPUT CONNECTOR PINOUT  
OUTPUT (16 pins)  
12V_OUTPUT (8 pins)  
INPUT  
Molex 430251600  
Molex 436450800  
JST VHR-5N  
Molex 430300008*  
Molex 430300008*  
JST SVH-41T-P1.1  
Pin 1  
Pin 3  
Pin 5  
Ground  
AC Neutral  
AC Line  
* Each contact rated for a maximum of 5.5 A.  
Product # AQ0500IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005055 Rev. D  
08/24/15  
Page 6  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 500 W  
Grade: Industrial  
Technical Specification  
MECHANICAL DRAWINGS  
(1 Module Encased Version - E Package Type)  
NOTES  
Ø.19 [4.8] PLASTIC RIVET OD.  
(applies to all mechanicals)  
TOP  
Right  
1) Recommended screw tightening  
torque of 6 in lbs  
2) Undimensioned components are  
shown for visual reference only  
3) All dimensions in inches (mm)  
Tolerances:  
x.xx in ± 0.02  
x.xxx in ± 0.010  
4.13 [104.8]  
5.25  
[133.4]  
3.03  
[76.8]  
Manufacturing Label  
PN#  
DATE CODE  
S/N  
.75 [19.1]  
1.75 [44.5]  
1.48  
[37.5]  
3.50 [88.9]  
Front  
6 - 32 Self - Clinching Insert  
Mounting Screw shall not Protude  
3/8” into the chassis (4 pieces)  
Bottom  
3.59 [91.3]  
1.63  
[41.3]  
.70  
[17.8]  
1.31  
[33.1]  
.11  
[2.9]  
Back  
4.91  
[124.7]  
1.05  
[26.6]  
.38  
[9.5]  
.23 [5.9]  
.17 [4.3]  
3.04 [77.1]  
Product # AQ0500IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005055 Rev. D  
08/24/15  
Page 7  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 500 W  
Grade: Industrial  
Technical Specification  
MECHANICAL DRAWINGS  
(2 Modules Flat Version - R Package Type)  
3.63 [92.1]  
.38 [9.5]  
Front  
1.05 [26.7]  
INPUT  
5
3
1
5
3
1
Ø.19 [4.75] PLASTIC RIVET OD.  
6.75 [171.5]  
5.00 [127]  
1.48  
[37.5]  
TOP  
1.75 [44.5]  
Right  
5.25  
[133.4]  
4.88 [123.8]  
3.03  
[76.8]  
6.84[173.8]  
.75 [19.1]  
1.63 [41.3]  
16 15 14 13 12 11 10  
9
1
16 15 14 13 12 11 10  
8 7 6 5 4 3 2  
9
1
8
7
6
5
4
3
2
OUTPUT  
OUTPUT  
1.31 [33.1]  
.71 [18]  
.23[5.9]  
Back  
4.56[115.7]  
6.29[159.6]  
Bottom  
3.14[79.8]  
.17[4.3]  
6 - 32 Self - Clinching Insert  
Mounting Screw shall not Protude  
3/8” into the chassis (6 pieces)  
4.91[124.7]  
Product # AQ0500IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005055 Rev. D  
08/24/15  
Page 8  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 500 W  
Grade: Industrial  
Technical Specification  
MECHANICAL DRAWINGS  
(3 Modules Flat Version - T Package Type)  
6.88 [174.6]  
3.63 [92.1]  
.38 [9.5]  
1.05  
[26.7]  
5
3
1
5
3
1
5
3
1
Ø .19  
[4.8]  
PLASTIC RIVET OD.  
INPUT  
1.48  
[37.5]  
5.25  
[133.4]  
4.88  
[123.8]  
3.03  
[76.8]  
1.75 [44.5]  
.75  
[19.1]  
5.00 [127]  
8.25 [12.096]  
10.00 [254]  
10.09 [256.4]  
1.63  
[41.3]  
16 15 14 13 12 11 10  
9
1
16 15 14 13 12 11 10  
9
1
16 15 14 13 12 11 10  
9
1
8
7
6
5
4
3
2
8
7
6
5
4
3
2
8
7
6
5
4 3 2  
.71  
[18]  
OUTPUT  
OUTPUT  
OUTPUT  
1.31 [33.1]  
4.56 [115.7]  
6.39 [162.4]  
7.81 [198.2]  
9.54 [242.2]  
.23 [5.9]  
.17 [4.3]  
3.14 [79.8]  
6 - 32 SELF-CLINCHING INSERT  
MOUNTING SCREW SHALL NOT  
PROTUDE 3/8INTO THE CHASSIS  
(6 PIECES)  
4.91  
[124.7]  
Product # AQ0500IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005055 Rev. D  
08/24/15  
Page 9  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 500 W  
Grade: Industrial  
Technical Specification  
PARALLEL OPERATION - MULTIPLE UNITS  
Chassis configurations for Parallel Units  
Specifications of Parallel Units  
ACuQor units are available either open-frame or pre-mounted As a rule, units wired in parallel behave the same as single units.  
at the factory. Up to 3 units can be mounted into a chassis, in Any specification will remain unchanged that is expressed in units  
either side-by-side or stacked configurations. For a complete list of of voltage, time, frequency, or efficiency. Specifications expressed  
options, see the “Part Numbering System” table on the last page, in terms of power, current, or capacitance, should be scaled by the  
under “Package Type”, along with the Mechanical Drawings pages. number of units wired in parallel.  
Only side-by-side configurations can be populated with 500W units,  
ACuQor units are individually calibrated at the factory, so that the  
output voltage vs. output current characteristic is always consistent  
(see Vout droop characteristic figures). As such, multiple units will  
share output current accurately. Full current is guaranteed from a  
bank of multiple units wired in parallel.  
since each includes a thermal pad underneath.  
Interconnection of Parallel Units  
ACuQor units mounted in 2 and 3 unit chassis are not connected  
together. This allows the physical routing and connectivity of the  
external wiring to be customized to each application. The following  
table summarizes the recommended wiring to operate multiple units  
in parallel:  
Output Connector Signal  
REMOTE_ENABLE  
FAN_GOOD  
Suggested Connection  
Behavior with Multiple Units  
Wire in parallel  
Inputs activated simultaneously  
Wired-OR outputs – can be pulled low by any unit during an abnormal condition.  
AC_POWER_GOOD  
DC_POWER_GOOD  
VOUT(+), VOUT(-)  
12V_STANDBY*  
5V_STANDBY  
Built-in droop characteristic ensures graceful current sharing.  
Do not wire in parallel Fully regulated characteristic does not support current sharing. If placed in  
parallel, only the output with the highest set-point will drive current.  
*Note: Triple output models only.  
Product # AQ0500IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005055 Rev. D  
08/24/15  
Page 10  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 500 W  
Grade: Industrial  
INSTALLATION INSTRUCTIONS  
Output: Refer to the Connector Details section for output  
connector wiring and signal I/O functionality. Refer to nameplate  
label for output current ratings. Main DC output (Vout+, Vout-) pins  
General: ACuQor AC/DC power supplies are intended for use  
as components in industrial equipment. ACuQor units must be  
properly installed within end use equipment before they can be  
safely applied as described in this document. The suitability of  
the ACuQor/equipment combination must be verified through end  
product investigation.  
2
should use 20 AWG (0.5mm ) wire size. Individual main output  
pins should not be loaded to more than 5.5 A. For currents greater  
than 5.5 A, multiple main output pins/wires must be used in  
parallel. All signal I/O pins are referenced to Vout-.  
Mounting: Refer to the Mechanical Drawings section. ACuQor  
units are provided with threaded stainless-steel stand-offs or inserts  
for mounting. This mounting hardware is internally connected to  
the input connector protective-earth terminal for functional-earth  
EMC control. Any orientation (vertical, horizontal, etc.) may be  
used. Adequate air space should be provided over the fan intake  
(top) and exhaust (sides) to allow for exchange of cooling air.  
ACuQor is designed for a pollution degree 2 environment. The  
suitability of the enclosed ACuQor mechanical assemblies must be  
verified through end product investigation.  
EMC: ACuQor products have been tested to the EMC specifications  
listed in the Electrical Characteristics section. However, end use  
equipment must be tested to verify EMC compliance..  
Hipot Testing: ACuQor products are rated for Hipot testing  
levels of 1500 Vac input to protective-earth, 500 Vac output to  
protective-earth, and 3000 Vac input to output. When performing  
the 3000 Vac input to output test, the test voltage must be  
balanced evenly1500 Vac input and output to protective-earth.  
Two oppositely phased test voltage sources or a single test voltage  
source with external balancing impedances (capacitors) may be  
used to prevent overstressing input or output to protective-earth  
insulation per IEC/ENC 60950-1.  
Encased models: A minimum of 5 mm electrical clearance  
should be allowed from the connector ends of encased models.  
Input: Refer to the Connector Details section for input connector  
wiring. ACuQor products require a single phase AC power  
source of 100-240V 50/60Hz nominal. Refer to nameplate  
label for input current ratings. A protective-earth connection  
CONDUCTIVE COOLING: This product requires supplemental  
conductive cooling through its case to maintain the rated output  
power. The case should be mounted to a system chassis or heat  
sink with a thermally conductive interface material and kept at  
50°C maximum to maintain full power rating of the product. For  
detailed applications assistance, consult Applications Engineering  
through the sales channel.  
2
is also required. Minimum wire size of 18 AWG (0.8mm ) is  
recommended. Both sides of the AC line are internally fused (see  
table for specific models). These fuses are not user replaceable.  
MODEL  
AQ0300  
AQ0400  
AQ0500  
AQ0800*  
AQ1200*  
Input Fuses (in Both AC Lines)  
Littelfuse 6.3A 250V 21606.3XEP  
Littelfuse 6.3A 250V 21606.3XEP  
Littelfuse 10.0A 250V 216010XEP  
Littelfuse 6.3A 250V 21606.3XEP  
Littelfuse 6.3A 250V 21606.3XEP  
*(4 fuses total)  
*(6 fuses total)  
Product # AQ0500IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005055 Rev. D  
08/24/15  
Page 11  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 500 W  
Grade: Industrial  
Ordering Information  
PART NUMBERING SYSTEM  
The part numbering system for SynQor’s ACuQor AC/DC power supplies follows the format shown in the table below.  
Not all combinations make valid part numbers, please contact SynQor for availability.  
Thermal  
Design  
Family  
Output Power  
Grade  
Range  
Output Voltage Package Type  
Options  
0300: 300 W  
0400: 400 W  
0500: 500 W  
0600: 600 W  
(2 x 300 W)  
0800: 800 W  
(2 x 400 W)  
0900: 900 W  
(3 x 300 W)  
1000: 1000 W  
(2 x 500 W)  
1200: 1200 W  
(3 x 400 W)  
1500: 1500 W  
(3 x 500 W)  
12: 12 V  
1T: 12 V /  
5 & 12 V STBY  
AQ:  
ACuQor series  
of AC-DC  
semi-regulated  
output power  
supplies  
24: 24 V  
E: 1 unit (3"x5")  
2T: 24 V /  
R: 2 units; flat  
5 & 12 V STBY  
S: 2 units; stacked  
U: Universal  
A: Open frame  
C: Encased  
Industrial Grade:  
IND: Industrial  
I: (Industrial)  
(85-264 VRMS) 36: 36 V  
3T: 36 V /  
T: 3 units; flat  
U: 3 units; stacked  
5 & 12 V STBY  
48: 48 V  
4T: 48 V /  
5 & 12 V STBY  
Example: AQ0500IU12ECIND  
ACCESSORIES  
SynQor offers a series of assemblies that can be ordered according to the table below. Mechanical drawings for these  
accessories are available for download in pdf format from the SynQor website.  
Part Number  
Description  
Input mating cable with pre-stripped wire ends (36” long).  
Output mating cables with pre-stripped wire ends (18” long).  
Same as AQ-CBL -OUT1C with an additional 8-pins connector.  
Output mating cable with connectors on both ends (18" long).  
Same as the AQ-CBL-OUT2C with an additional 8-pins connector.  
Single module bottom-side Mylar insulator for open frame mounting  
Evaluation board for up to three paralleled modules.  
AQ-CBL-INPUT1C  
AQ-CBL-OUT1C  
AQ-CBL-OUT1CD  
AQ-CBL-OUT2C  
AQ-CBL-OUT2CD  
AQ-INSUL1M  
AQ-EVAL-PRL3  
APPLICATION NOTES  
A variety of application notes and technical white papers can be downloaded in pdf format from the SynQor website.  
Online Application Notes  
Online Library of Technical White Papers  
SynQor website.  
Contact SynQor for further information and to order:  
PATENTS  
SynQor holds numerous U.S. patents, one or more of which apply to most of its power converter  
products. Any that apply to the product(s) listed in this document are identified by markings on  
the product(s) or on internal components of the product(s) in accordance with U.S. patent laws.  
SynQor’s patents include the following:  
Phone:  
Toll Free:  
Fax:  
E-mail:  
Web:  
978-849-0600  
888-567-9596  
978-849-0602  
power@synqor.com  
www.synqor.com  
155 Swanson Road  
Boxborough, MA 01719  
USA  
5,999,417  
6,896,526  
7,269,034  
7,787,261  
6,222,742  
6,927,987  
7,272,021  
8,023,290  
6,545,890  
7,050,309  
7,272,023  
8,149,597  
6,594,159  
7,072,190  
7,558,083  
8,493,751  
6,731,520  
7,085,146  
7,564,702  
8,644,027  
6,894,468  
7,119,524  
7,765,687  
Address:  
WARRANTY  
SynQor offers a two (2) year limited warranty. Complete warranty  
information is listed on our website or is available upon request from SynQor.  
Product # AQ0500IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005055 Rev. D  
08/24/15  
Page 12  

相关型号:

AQ-CBL-OUT1CDG

Integral fan cooling with speed control
SYNQOR

AQ-CBL-OUT2C

Semi-regulated output for bus stability
SYNQOR

AQ-CBL-OUT2CD

Semi-regulated output for bus stability
SYNQOR

AQ010001

MAT AQUA 0.6X0.9 GREY
ETC

AQ010002

MAT AQUA 1.5X0.9 GREY
ETC

AQ010004

MAT AQUA 1.2X1.8 GREY
ETC

AQ020001

MAT AQUA 0.6X0.9 BLUE
ETC

AQ020002

MAT AQUA 1.5X0.9 BLUE
ETC

AQ020004

MAT AQUA 1.8X1.2 BLUE
ETC

AQ0300IU12EAIND

AC-DC Regulated Power Supply Module, ROHS COMPLIANT
SYNQOR

AQ0300IU12ECIND

AC-DC Regulated Power Supply Module, ROHS COMPLIANT
SYNQOR

AQ0300IU12EQIND

AC-DC Regulated Power Supply Module, ROHS COMPLIANT
SYNQOR