Technical
Specification
500 W Triple Vout Series
Industrial Grade AC/DC Power Supply With PFC
85-264 Vrms
12/24/36/48 V
500 W
700 W
Up to 90 %
Input Voltage
Semi-Regulated Output
Output Continuous Output Transient Full Load Efficiency
Includes 5 V (10 W) and 12 V (50 W) “Always On” Standby Power Outputs
1500 W Encased
1000 W Encased
Package Configurations Available
to three units can be factory mounted into a chassis.
The 500 W Triple Vout Series can be configured as follows:
500 W Encased
•ꢀ500ꢀWꢀ(1ꢀunit)ꢀ
•ꢀ1000ꢀWꢀ(2ꢀunits)ꢀ
•ꢀ1500ꢀWꢀ(3ꢀunits)
Product Features
• High efficiency (90% for 48 VOUT Model at 500 W)
• Universal input voltage range
• DC Power Good / AC Power Good signals
• Remote enable input
• Semi-regulated output for bus stability
• Parallel operation supported
• Fan status output / Fan enable input
• Small size: 3.59" x 5.25" x 1.63"
• RoHS 6/6 compliant
• Integral fan cooling with speed control
• Active PFC; EN61000-3-2 compliant
• 5 V (10 W) and 12 V (50 W) standby outputs
• Low noise; EN55011 / EN55022 Class B compliant
• Over–current, over–voltage, and over–temp protection
Product # AQ0500IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005055 Rev. D
08/24/15
Page 1
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 500 W
Grade: Industrial
Technical Specification
ACuQor 500W Triple Vout Series Electrical Characteristics
All specifications typical with TA = 25 °C, unless otherwise specified. Specifications subject to change without notice.
GENERAL SPECIFICATIONS
MAIN OUTPUT SPECIFICATIONS
Output power (continuous) 85-132/170-264 Vrms
Fundamental ripple freq.
Input
Output
500 kHz
250 kHz
39 dBA @ 1 m max.
500 W (Note 1)
700 W (Note 1)
See Figures 11, 12
(5 s transient)
85-132/170-264 Vrms
132-170 Vrms
Audible noise
Weight
Fan speed varies with temp.
(EC)
(RC)
(TC)
540 g (19.1 oz)
1068 g (37.7 oz)
1582 g (55.8 oz)
Nominal DC output
voltage (at 250W)
(Semi-regulated)
12 Vout (model 1T)
24 Vout (model 2T)
36 Vout (model 3T)
48 Vout (model 4T)
12.4 V
25 V
37.5 V
50 V
MTBF
MIL-217
343.6 kHours
TBD kHours
Demonstrated
Efficiency
(see figs. 1, 3, 5, 7)
(see Note 1)
12 Vout, 115 Vrms, 500 W
48 Vout, 115 Vrms, 500 W
12 Vout, 230 Vrms, 500 W
48 Vout, 230 Vrms, 500 W
86% typ.
89% typ.
88% typ.
90% typ.
ISOLATION SPECIFICATIONS
Isolation voltage
Input to output
Input to ground
Output to ground
3000 Vrms
1500 Vrms
500 Vrms
Hold-up time (to -20%)
(see Note 1)
12 Vout
24 / 36 / 48 Vout
12 ms @ 500 W
16 ms @ 500 W
Maximum load capacitance 12 Vout
16,000 µF
8,000 µF
4,000 µF
2,000 µF
Insulation resistance
Leakage currents
Output to ground
10 MΩ min.
24 Vout
36 Vout
48 Vout
See Note 2
ENVIRONMENTAL CHARACTERISTICS
Thermal performance
Operating ambient (see Figure 2)
Non-operating ambient
-40 ºC to +70 ºC
-40 ºC to +85 ºC
Output ripple voltage
Switching frequency (20 MHz BW)
Twice line frequency (at 300 W)
0.5% p-p
5.0% p-p
Relative humidity
Altitude
Non-condensing
5-95% RH
Turn-on delay
2 s max.
Operating
Non-operating
5-500 Hz
10,000 ft max.
30,000 ft max.
Transient response
Iout steps from 50-75%
At 0.2 A/µs
Cyclic restart
3% typ / 6% max. dev.
100 ms recovery
Random vibration
Shock
0.03 g2/Hz
Overvoltage protection
Short circuit protection
Total regulation
110-120%
115% rated Iout
±6.0%
Half-sine, 10 ms, 3 axes
20 g peak
Cyclic operation
EMC CHARACTERISTICS
Conducted emissions
Over line, load and temperature
EN55011 and EN55022, FCC
part15
Level B
12V_STANDBY cross-reg. ΔVout caused by 50 W step
0.5%
Line frequency harmonics EN61000-3-2
Class A
Clause 5b
Level 3
Level 3
Level 3
Level 3
Level 3
Level 3
3 A/m
ΔVout caused by 10 W step
5V_STANDBY cross-reg.
Thermal protection
REMOTE_ENABLE
0.1%
Voltage fluctuations
ESD air
EN61000-3-3
EN61000-4-2
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Automatic recovery
+125 ºC (PCB Temp)
Input Low Voltage
Input High Voltage
0.45 V (max)
4.15 V (min)
ESD contact
Radiated immunity
Fast transients
12V_STANDBY OUTPUT SPECIFICATIONS
Output power 85-264 Vrms
Nominal DC output voltage Semi-regulated
50 W
12.4 V
Line surge immunity
Conducted immunity
Power freq. mag. field
Voltage dip immunity
Total regulation
Over line, load and temperature
±6.0%
400 mV
Main output cross-reg.
Δ12V_STANDBY caused by Δ350W
on main output
Switching frequency (20 MHz BW)
Twice line frequency
Perf Criteria A, A, B
<5% UT 10 ms,
70% UT 500 ms,
40% UT 100 ms
Output ripple
10 mV
0.45 Vrms
Output current
Continuous
4.2 A
5.0 A
NOTES:
Short circuit protection
Maximum load capacitance
Cyclic operation
1.Main output power rating always includes 5 V and 12 V standby outputs.
2. Leakage currents see page 5.
2,000 uF
5V_STANDBY OUTPUT SPECIFICATIONS
Output power 85-264 Vrms
Nominal DC output voltage Fully regulated
10 W
5.0 V
Total regulation
Over line, load and temperature
±5.0%
2.0 A
Output current
Continuous
Short circuit protection
Maximum load capacitance
Cyclic operation
2.5 A
1,000 uF
INPUT SPECIFICATIONS
AC input voltage
Universal range
85-264 Vrms
47-63 Hz
Input frequency
Input current
(see Note 1)
115 Vrms @ 500 W
230 Vrms @ 500 W
5 Arms
2.5 Arms
Power factor
>0.98
40 A max.
10.0 A
Input surge current
Internal input fuses
264 Vrms (cold start)
Both AC lines
Product # AQ0500IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005055 Rev. D
08/24/15
Page 2
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 500 W
Grade: Industrial
Technical Specification
EFFICIENCY, DERATING, AND VOUT DROOP CURVES
100
13.5
13.0
12.5
12.0
11.5
11.0
10.5
95
90
85
80
75
70
65
Continuous
115 Vrms
230 Vrms
44
50
0
6
12
18
24
30
36
42
48
54
60
0
100
200
300
400
500
600
700
Output Load (A)
Output Power (W)
Figure 1: 12 VOUT efficiency curves.
Figure 2: 12 VOUT droop characteristic.
100
95
90
85
80
75
70
65
27
26
25
24
Continuous
23
22
21
115 Vrms
230 Vrms
22
25
0
100
200
300
400
500
600
700
0
6
12
18
24
30
Output Load (A)
Output Power (W)
Figure 3: 24 VOUT efficiency curves.
Figure 4: 24 VOUT droop characteristic.
100
95
90
85
80
75
70
65
40.5
39.0
37.5
36.0
Continuous
34.5
33.0
31.5
115 Vrms
230 Vrms
16.5
18.75
0
3
6
9
12
15
18
21
0
100
200
300
400
500
600
700
Output Load (A)
Output Power (W)
Figure 5: 36 VOUT efficiency curves.
Figure 6: 36 VOUT droop characteristic.
Product # AQ0500IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005055 Rev. D
08/24/15
Page 3
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 500 W
Grade: Industrial
Technical Specification
EFFICIENCY, DERATING, AND VOUT DROOP CURVES
54
52
50
48
46
44
42
100
95
90
85
80
75
70
65
Continuous
115 Vrms
230 Vrms
11
12.5
0
100
200
300
400
500
600
700
0
3
6
9
12
15
Output Power (W)
Output Load (A)
Figure 7: 48 VOUT efficiency curves.
Figure 8: 48 VOUT droop characteristic.
600
500
400
300
200
600
500
400
300
200
24 / 36 / 48 V, VIN≥ 105 Vrms
12 V, VIN≥ 105 Vrms
24 / 36 / 48 V with Fan Enabled
12 V with Fan Enabled
100
100
0
24 / 36 / 48 V, VIN = 85 Vrms
12 V, VIN = 85 Vrms
0
0
10
20
30
40
50
60
70
80
0
10
20
30
40
50
60
70
80
Case Temperature (ºC)
Ambient / Case Temperature (ºC)
Figure 9: Continuous power derating curve in natural convection.
Figure 10: Fan Disabled continuous power derating curve in natural
For Fan Disabled, see Figure 10
convection
800
700
600
500
400
300
800
700
600
500
400
300
200
200
Transient (24/36/48 V Out)
Transient (12 V Out)
100
100
0
Continuous (24/36/48 V Out)
Continuous (12 V Out)
0
132 150
264
85
132
264
85
105
170
210
170
InputAC Voltage (VRMS
)
InputAC Voltage (VRMS
)
Figure 11: Rated output power vs Input AC Voltage.
Figure 12: Rated output power vs Input AC Voltage.
Product # AQ0500IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005055 Rev. D
08/24/15
Page 4
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 500 W
Grade: Industrial
Technical Specification
Leakage Currents
AC Leakage Current
AC Line Connection
from Input to Earth
Normal Open Neutral
Condition
Fault
240 V L-N, 1 phase
400 µA
800 µA
ACuQor Typical at
110% nominal input 208 V L-L, 120 V L-N, 1 of 3 phases
200 µA
200 µA
400 µA
400 µA
voltage 60 Hz
240 V L-N-L, 120 V L-N, split phase
Standard Testing Certifications
SAFETY AGENCY CERTIFICATIONS
CAN/CSA-C22.2 No. 60950-1:2007
UL 60950-1:2007
EN 60950-1/A1:2010
CE Marked
Product # AQ0500IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005055 Rev. D
08/24/15
Page 5
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 500 W
Grade: Industrial
CONNECTOR DETAILS
OUTPUT CONNECTOR PINOUT (top side)
Pin 1 FAN_GOOD
Open collector with internal 5V pullup. See Figure A.
Pulsed low on fan failure, 100ms, 50% duty.
Short to VOUT(-) to disable fan.
Pin 2 AC_POWER_GOOD
Pin 3 DC_POWER_GOOD
Open collector with internal 5V pullup. See Figure B.
Pulled low on AC power dropout.
Open collector with internal 5V pullup. See Figure B.
Pulled low during startup ramp and within 5 ºC of
temperature shutdown threshold.
Pin 4 5V_STANDBY
Pin 5 VOUT(+)
Pin 6 VOUT(+)
Pin 7 VOUT(+)
Pin 8 VOUT(+)
Pin 9 Reserved
Pin 10 Reserved
Pin 11 REMOTE_ENABLE
5 V @ 10 W available whenever AC power is applied.
Positive Output Voltage.
Figure A: Fan status output / Fan enable input interface circuitry.
Positive Output Voltage.
Positive Output Voltage.
Positive Output Voltage.
Reserved for future use.
5V_STANDBY
Reserved for future use.
Logic input. See Figure C.
Pull high to enable main output.
N4148
Pin 12 12V_STANDBY
Pin 13 VOUT(–)
Pin 14 VOUT(–)
Pin 15 VOUT(–)
Pin 16 VOUT(–)
12 V @ 50 W available whenever AC power is applied.
Negative Output Voltage.
5 k
Negative Output Voltage.
10 Ohms
AC_POWER_GOOD or
DC_POWER_GOOD
Negative Output Voltage.
N3904
From AC/DC
Monitor
Negative Output Voltage.
0.1 µF
Circuitry
VOUT(-)
Figure B: Power good interface circuitry.
12 V OUTPUT CONNECTOR PINOUT (bottom side)
Pin 1 VOUT(+)
Pin 2 VOUT(+)
Pin 3 VOUT(+)
Positive Output Voltage.
Positive Output Voltage.
Positive Output Voltage.
Positive Output Voltage.
Negative Output Voltage.
Negative Output Voltage.
Negative Output Voltage.
Negative Output Voltage
5V_STANDBY
5V_STANDBY
VOUT(+)
Pin 4
Pin 5 VOUT(–)
Pin 6 VOUT(–)
Pin 7 VOUT(–)
Pin 8 VOUT(–)
10 Ohms
5 k
To Enable
Circuitry
REMOTE_ENABLE
0.1 µF
10k
VOUT(-)
Figure C: Remote enable interface circuitry.
MATING CONNECTORS
Connector
Type
Contact
INDIVIDUAL INPUT CONNECTOR PINOUT
OUTPUT (16 pins)
12V_OUTPUT (8 pins)
INPUT
Molex 430251600
Molex 436450800
JST VHR-5N
Molex 430300008*
Molex 430300008*
JST SVH-41T-P1.1
Pin 1
Pin 3
Pin 5
Ground
AC Neutral
AC Line
* Each contact rated for a maximum of 5.5 A.
Product # AQ0500IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005055 Rev. D
08/24/15
Page 6
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 500 W
Grade: Industrial
Technical Specification
MECHANICAL DRAWINGS
(1 Module Encased Version - E Package Type)
NOTES
Ø.19 [4.8] PLASTIC RIVET OD.
(applies to all mechanicals)
TOP
Right
1) Recommended screw tightening
torque of 6 in lbs
2) Undimensioned components are
shown for visual reference only
3) All dimensions in inches (mm)
Tolerances:
x.xx in ± 0.02
x.xxx in ± 0.010
4.13 [104.8]
5.25
[133.4]
3.03
[76.8]
Manufacturing Label
PN#
DATE CODE
S/N
.75 [19.1]
1.75 [44.5]
1.48
[37.5]
3.50 [88.9]
Front
6 - 32 Self - Clinching Insert
Mounting Screw shall not Protude
3/8” into the chassis (4 pieces)
Bottom
3.59 [91.3]
1.63
[41.3]
.70
[17.8]
1.31
[33.1]
.11
[2.9]
Back
4.91
[124.7]
1.05
[26.6]
.38
[9.5]
.23 [5.9]
.17 [4.3]
3.04 [77.1]
Product # AQ0500IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005055 Rev. D
08/24/15
Page 7
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 500 W
Grade: Industrial
Technical Specification
MECHANICAL DRAWINGS
(2 Modules Flat Version - R Package Type)
3.63 [92.1]
.38 [9.5]
Front
1.05 [26.7]
INPUT
5
3
1
5
3
1
Ø.19 [4.75] PLASTIC RIVET OD.
6.75 [171.5]
5.00 [127]
1.48
[37.5]
TOP
1.75 [44.5]
Right
5.25
[133.4]
4.88 [123.8]
3.03
[76.8]
6.84[173.8]
.75 [19.1]
1.63 [41.3]
16 15 14 13 12 11 10
9
1
16 15 14 13 12 11 10
8 7 6 5 4 3 2
9
1
8
7
6
5
4
3
2
OUTPUT
OUTPUT
1.31 [33.1]
.71 [18]
.23[5.9]
Back
4.56[115.7]
6.29[159.6]
Bottom
3.14[79.8]
.17[4.3]
6 - 32 Self - Clinching Insert
Mounting Screw shall not Protude
3/8” into the chassis (6 pieces)
4.91[124.7]
Product # AQ0500IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005055 Rev. D
08/24/15
Page 8
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 500 W
Grade: Industrial
Technical Specification
MECHANICAL DRAWINGS
(3 Modules Flat Version - T Package Type)
6.88 [174.6]
3.63 [92.1]
.38 [9.5]
1.05
[26.7]
5
3
1
5
3
1
5
3
1
Ø .19
[4.8]
PLASTIC RIVET OD.
INPUT
1.48
[37.5]
5.25
[133.4]
4.88
[123.8]
3.03
[76.8]
1.75 [44.5]
.75
[19.1]
5.00 [127]
8.25 [12.096]
10.00 [254]
10.09 [256.4]
1.63
[41.3]
16 15 14 13 12 11 10
9
1
16 15 14 13 12 11 10
9
1
16 15 14 13 12 11 10
9
1
8
7
6
5
4
3
2
8
7
6
5
4
3
2
8
7
6
5
4 3 2
.71
[18]
OUTPUT
OUTPUT
OUTPUT
1.31 [33.1]
4.56 [115.7]
6.39 [162.4]
7.81 [198.2]
9.54 [242.2]
.23 [5.9]
.17 [4.3]
3.14 [79.8]
6 - 32 SELF-CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTUDE 3/8”INTO THE CHASSIS
(6 PIECES)
4.91
[124.7]
Product # AQ0500IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005055 Rev. D
08/24/15
Page 9
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 500 W
Grade: Industrial
Technical Specification
PARALLEL OPERATION - MULTIPLE UNITS
Chassis configurations for Parallel Units
Specifications of Parallel Units
ACuQor units are available either open-frame or pre-mounted As a rule, units wired in parallel behave the same as single units.
at the factory. Up to 3 units can be mounted into a chassis, in Any specification will remain unchanged that is expressed in units
either side-by-side or stacked configurations. For a complete list of of voltage, time, frequency, or efficiency. Specifications expressed
options, see the “Part Numbering System” table on the last page, in terms of power, current, or capacitance, should be scaled by the
under “Package Type”, along with the Mechanical Drawings pages. number of units wired in parallel.
Only side-by-side configurations can be populated with 500W units,
ACuQor units are individually calibrated at the factory, so that the
output voltage vs. output current characteristic is always consistent
(see Vout droop characteristic figures). As such, multiple units will
share output current accurately. Full current is guaranteed from a
bank of multiple units wired in parallel.
since each includes a thermal pad underneath.
Interconnection of Parallel Units
ACuQor units mounted in 2 and 3 unit chassis are not connected
together. This allows the physical routing and connectivity of the
external wiring to be customized to each application. The following
table summarizes the recommended wiring to operate multiple units
in parallel:
Output Connector Signal
REMOTE_ENABLE
FAN_GOOD
Suggested Connection
Behavior with Multiple Units
Wire in parallel
Inputs activated simultaneously
“
“
“
“
“
Wired-OR outputs – can be pulled low by any unit during an abnormal condition.
AC_POWER_GOOD
DC_POWER_GOOD
VOUT(+), VOUT(-)
12V_STANDBY*
5V_STANDBY
“
“
Built-in droop characteristic ensures graceful current sharing.
“
Do not wire in parallel Fully regulated characteristic does not support current sharing. If placed in
parallel, only the output with the highest set-point will drive current.
*Note: Triple output models only.
Product # AQ0500IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005055 Rev. D
08/24/15
Page 10
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 500 W
Grade: Industrial
INSTALLATION INSTRUCTIONS
Output: Refer to the Connector Details section for output
connector wiring and signal I/O functionality. Refer to nameplate
label for output current ratings. Main DC output (Vout+, Vout-) pins
General: ACuQor AC/DC power supplies are intended for use
as components in industrial equipment. ACuQor units must be
properly installed within end use equipment before they can be
safely applied as described in this document. The suitability of
the ACuQor/equipment combination must be verified through end
product investigation.
2
should use 20 AWG (0.5mm ) wire size. Individual main output
pins should not be loaded to more than 5.5 A. For currents greater
than 5.5 A, multiple main output pins/wires must be used in
parallel. All signal I/O pins are referenced to Vout-.
Mounting: Refer to the Mechanical Drawings section. ACuQor
units are provided with threaded stainless-steel stand-offs or inserts
for mounting. This mounting hardware is internally connected to
the input connector protective-earth terminal for functional-earth
EMC control. Any orientation (vertical, horizontal, etc.) may be
used. Adequate air space should be provided over the fan intake
(top) and exhaust (sides) to allow for exchange of cooling air.
ACuQor is designed for a pollution degree 2 environment. The
suitability of the enclosed ACuQor mechanical assemblies must be
verified through end product investigation.
EMC: ACuQor products have been tested to the EMC specifications
listed in the Electrical Characteristics section. However, end use
equipment must be tested to verify EMC compliance..
Hipot Testing: ACuQor products are rated for Hipot testing
levels of 1500 Vac input to protective-earth, 500 Vac output to
protective-earth, and 3000 Vac input to output. When performing
the 3000 Vac input to output test, the test voltage must be
balanced evenly1500 Vac input and output to protective-earth.
Two oppositely phased test voltage sources or a single test voltage
source with external balancing impedances (capacitors) may be
used to prevent overstressing input or output to protective-earth
insulation per IEC/ENC 60950-1.
Encased models: A minimum of 5 mm electrical clearance
should be allowed from the connector ends of encased models.
Input: Refer to the Connector Details section for input connector
wiring. ACuQor products require a single phase AC power
source of 100-240V 50/60Hz nominal. Refer to nameplate
label for input current ratings. A protective-earth connection
CONDUCTIVE COOLING: This product requires supplemental
conductive cooling through its case to maintain the rated output
power. The case should be mounted to a system chassis or heat
sink with a thermally conductive interface material and kept at
50°C maximum to maintain full power rating of the product. For
detailed applications assistance, consult Applications Engineering
through the sales channel.
2
is also required. Minimum wire size of 18 AWG (0.8mm ) is
recommended. Both sides of the AC line are internally fused (see
table for specific models). These fuses are not user replaceable.
MODEL
AQ0300
AQ0400
AQ0500
AQ0800*
AQ1200*
Input Fuses (in Both AC Lines)
Littelfuse 6.3A 250V 21606.3XEP
Littelfuse 6.3A 250V 21606.3XEP
Littelfuse 10.0A 250V 216010XEP
Littelfuse 6.3A 250V 21606.3XEP
Littelfuse 6.3A 250V 21606.3XEP
*(4 fuses total)
*(6 fuses total)
Product # AQ0500IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005055 Rev. D
08/24/15
Page 11
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 500 W
Grade: Industrial
Ordering Information
PART NUMBERING SYSTEM
The part numbering system for SynQor’s ACuQor AC/DC power supplies follows the format shown in the table below.
Not all combinations make valid part numbers, please contact SynQor for availability.
Thermal
Design
Family
Output Power
Grade
Range
Output Voltage Package Type
Options
0300: 300 W
0400: 400 W
0500: 500 W
0600: 600 W
(2 x 300 W)
0800: 800 W
(2 x 400 W)
0900: 900 W
(3 x 300 W)
1000: 1000 W
(2 x 500 W)
1200: 1200 W
(3 x 400 W)
1500: 1500 W
(3 x 500 W)
12: 12 V
1T: 12 V /
5 & 12 V STBY
AQ:
ACuQor series
of AC-DC
semi-regulated
output power
supplies
24: 24 V
E: 1 unit (3"x5")
2T: 24 V /
R: 2 units; flat
5 & 12 V STBY
S: 2 units; stacked
U: Universal
A: Open frame
C: Encased
Industrial Grade:
IND: Industrial
I: (Industrial)
(85-264 VRMS) 36: 36 V
3T: 36 V /
T: 3 units; flat
U: 3 units; stacked
5 & 12 V STBY
48: 48 V
4T: 48 V /
5 & 12 V STBY
Example: AQ0500IU12ECIND
ACCESSORIES
SynQor offers a series of assemblies that can be ordered according to the table below. Mechanical drawings for these
accessories are available for download in pdf format from the SynQor website.
Part Number
Description
Input mating cable with pre-stripped wire ends (36” long).
Output mating cables with pre-stripped wire ends (18” long).
Same as AQ-CBL -OUT1C with an additional 8-pins connector.
Output mating cable with connectors on both ends (18" long).
Same as the AQ-CBL-OUT2C with an additional 8-pins connector.
Single module bottom-side Mylar insulator for open frame mounting
Evaluation board for up to three paralleled modules.
AQ-CBL-INPUT1C
AQ-CBL-OUT1C
AQ-CBL-OUT1CD
AQ-CBL-OUT2C
AQ-CBL-OUT2CD
AQ-INSUL1M
AQ-EVAL-PRL3
APPLICATION NOTES
A variety of application notes and technical white papers can be downloaded in pdf format from the SynQor website.
Online Application Notes
Online Library of Technical White Papers
SynQor website.
Contact SynQor for further information and to order:
PATENTS
SynQor holds numerous U.S. patents, one or more of which apply to most of its power converter
products. Any that apply to the product(s) listed in this document are identified by markings on
the product(s) or on internal components of the product(s) in accordance with U.S. patent laws.
SynQor’s patents include the following:
Phone:
Toll Free:
Fax:
E-mail:
Web:
978-849-0600
888-567-9596
978-849-0602
power@synqor.com
www.synqor.com
155 Swanson Road
Boxborough, MA 01719
USA
5,999,417
6,896,526
7,269,034
7,787,261
6,222,742
6,927,987
7,272,021
8,023,290
6,545,890
7,050,309
7,272,023
8,149,597
6,594,159
7,072,190
7,558,083
8,493,751
6,731,520
7,085,146
7,564,702
8,644,027
6,894,468
7,119,524
7,765,687
Address:
WARRANTY
SynQor offers a two (2) year limited warranty. Complete warranty
information is listed on our website or is available upon request from SynQor.
Product # AQ0500IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005055 Rev. D
08/24/15
Page 12
相关型号:
©2020 ICPDF网 联系我们和版权申明