TDK Switching Power Supply  
Mechatronics power supply with 5V and 24V insulated  
E SERIES ECX  
[FEATURES]  
• AC.100V/200V input and switching type.  
• Floating between outputs 5V and 24V.  
• Large 24V peak current (ECX-001/-003/-005/-007).  
• Optimum for pulse load and mechanism drive.  
• Compact and lightweight.  
[SUMMARY]  
The E series ECX products are 2-output power supplies of 5V  
type for a logic circuit and 24V type for driving a mechanism. This  
series has no limitation on the minimum output current and has  
superior characteristics of dynamic load variation from a light load  
to a rated load so as to obtain a large peak current (24V output),  
thus enabling a wide variety of uses for mechatronics.  
PART NUMBERS AND RATINGS  
Maximum output power(W)  
Output current(A)  
5V  
Part No.  
(Peak)  
29(41)  
39  
24V  
24V Peak  
ECX-001  
ECX-002  
ECX-003  
ECX-004  
ECX-005  
ECX-006  
ECX-007  
0 to 1  
0 to 1  
0 to 1  
0 to 1.5  
0 to 2  
0 to 3  
0 to 3  
0 to 6  
1.5(10s min.)  
3(10s min.)  
5(10s min.)  
10(10s min.)  
0 to 3  
43.5(79.5)  
63  
0 to 1.5  
0 to 3  
82(130)  
87  
0 to 2  
0 to 3  
159(255)  
0 to 3  
PRODUCT IDENTIFICATIONS  
Input and output style  
Terminal block  
Open frame type  
ECX-00 A( : only for 1, and 2)  
L-shape frame type  
ECX-00  
ECX-00  
D
E
Connector(Vertical)  
There are 1 to 7 types available for the square  
.
All specifications are subject to change without notice.  
A131_ECX  
(2/21)  
TDK Switching Power Supply  
E SERIES ECX-001  
SPECIFICATIONS AND STANDARDS  
PART NO.  
ECX-001  
Rated output voltage  
and current1  
V1  
V2  
W
5V • 1A  
24V • 1A(Peak current 1.5A)  
29[Peak current output: 41]  
Maximum output power  
INPUT CONDITIONS  
Input voltage Eac6  
Input frequency  
Input current  
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)  
Hz  
A
47 to 66[Rating: 50 to 60](Single phase)  
1max.[25°C, input and output ratings]  
3[Built-in]  
Fuse rating  
A
Surge current2  
Leakage current  
Efficiency  
A
50max.[25°C, cold start]  
1max.[25°C, input and output ratings]  
75typ.  
mA  
%
OUTPUT CHARACTERISTICS  
Output voltage Edc  
Voltage variable range Edc  
Maximum output current  
Minimum output current  
Input variation  
V
5(V1)  
24(V2)  
V
Fixed  
Fixed  
A
1
1(Peak current 1.5A 10s max.)  
A
0
0
%
1max.  
3.5max. [Within the input voltage range]  
Load variation3  
%
2max.  
5max.  
2max.  
[V2: 10 to 100%]  
4 Total variation 5max.(24V: 10max.)  
Voltage  
stability  
Temperature variation  
%
1max.  
[Ambient temperature: 0 to +40°C]  
Drift  
%
0.5max.  
1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]  
Dynamic load  
Ripple Ep-p5  
Ripple noise Ep-p5  
V/ms  
mV  
mV  
s
2.4(Voltage variation)/5(Reset time)[0.1 to 1.5A sudden load change]  
100max.  
600max.  
800max.  
150max.  
Start up time  
1.5max.(Rise time: 20ms max.)  
20min.  
Normal temperature, input and output ratings,  
load capacitance 100µF max.  
Hold up time  
ms  
AUXILIARY FUNCTIONS  
Indicator display  
No  
V1, V2 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset  
(restart requires roughly 5min wait).  
Overvoltage protection  
Overcurrent protection7  
V1 alone uses voltage lowering. V2 entirely shuts off output upon overcurrent detection or winker  
operation(restart requires roughly 5min wait).  
Remote ON-OFF  
Remote sensing  
Current balance  
STANDARDS  
No  
No  
No  
Safety standards  
Noise terminal voltage  
CONSTRUCTIONS  
External dimensions  
Weight  
mm  
g
A type: 24×93×119[H×W×L] D, E type: 25×95×120[H×W×L]  
300max.  
Mounting method  
Case material  
Can be attached to 2 sides(Without frame type can be attached to 1 side).  
Without cover(With frame also available)  
Input and output cables  
1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.  
The V2 peak current should be limited to 10 sec max. and the effective current should be used at the rated current or lower.  
2 A power thermistor is used as a surge current suppressing element.  
3 Determined within a range of 10 to 100% load variations.  
4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.  
5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.  
6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is  
connected to input 200V with the connector for the 100V use being connected.  
7 The output overcurrent protection is effective only for a short circuit.  
PRODUCT IDENTIFICATIONS  
Input and output style  
Terminal block  
Open frame type L-shape frame type  
ECX-001A  
ECX-001D  
ECX-001E  
Connector(Vertical)  
All specifications are subject to change without notice.  
A131_ECX  
(3/21)  
TDK Switching Power Supply  
E SERIES ECX-001  
Dimensions in mm  
SHAPES AND DIMENSIONS  
ECX-001  
M4×8  
110 0.7  
4-M3 Screw tap  
4-ø3.5  
5 0.3  
(5)  
(5.6) 20.4max.  
(for mounting, rear view) (for mounting)  
+
24V  
5V  
output  
+
G
L
input  
N
4-Length of installation screw  
8max.  
4.5 0.4  
119 1  
120 1  
5 0.3  
55 0.4  
UP  
55 0.4  
(5)  
ECX-001D(With frame)  
3-M3  
Screw tap  
(for mounting)  
ECX-001A(Without frame)  
UP  
(
): for reference dimensions mark is in case of without housing type.  
All specifications are subject to change without notice.  
A131_ECX  
(4/21)  
TDK Switching Power Supply  
E SERIES ECX-002  
SPECIFICATIONS AND STANDARDS  
PART NO.  
ECX-002  
5V 3A  
24V 1A  
39  
Rated output voltage  
and current1  
V1  
V2  
W
Maximum output power  
INPUT CONDITIONS  
Input voltage6 Eac  
Input frequency  
Input current  
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)  
Hz  
A
47 to 66[Rating: 50 to 60]](Single phase)  
1.2max.[25°C, input and output ratings]  
3[Built-in]  
Fuse rating  
A
Surge current2  
Leakage current  
Efficiency  
A
50max.[25°C, cold start]  
1max.[25°C, input and output ratings]  
75typ.  
mA  
%
OUTPUT CHARACTERISTICS  
Output voltage Edc  
Voltage variable range Edc  
Maximum output current  
Minimum output current  
Input variation  
V
5(V1)  
Fixed  
3
24(V2)  
Fixed  
1
V
A
A
0
0
%
1max.  
2max.  
1max.  
1max.  
3.5max.  
[Within the input voltage range]  
Load variation3  
%
+10, 8max. [V2 : 10 to 100%]  
5max. [0 to +40°C]  
4 Total variation 5max.(24V: +15, 10max.)  
Voltage  
stability  
Temperature variation  
%
Drift  
%
5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]  
Dynamic load  
Ripple5 Ep-p  
Ripple noise5 Ep-p  
V/ms  
mV  
mV  
s
100max.  
150max.  
600max.  
800max.  
Start up time  
1.5max.(Rise time: 20ms max.)  
20min.  
Normal temperature, input and output ratings,  
load capacitance 100µF max.  
Hold up time  
ms  
AUXILIARY FUNCTIONS  
Indicator display  
No  
Only V1 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset  
(restart requires roughly 5min wait).  
Overvoltage protection  
Overcurrent protection7  
Upon overcurrent detection, outputs are lowered and winker operates. Recovery when input reset  
(restart requires roughly 5min wait).  
Remote ON-OFF  
Remote sensing  
Current balance  
STANDARDS  
No  
No  
No  
Safety standards  
Noise terminal voltage  
CONSTRUCTIONS  
External dimensions  
Weight  
mm  
g
A type: 24×93×119[H×W×L]] D, E type: 25×95×120[H×W×L]  
300max.  
Mounting method  
Case material  
Can be attached to 2 sides(Without frame type can be attached to 1 side).  
Without cover(With frame also available)  
Input and output cables  
1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.  
2 A power thermistor is used as a surge current suppressing element.  
3 Determined within a range of 10 to 100% load variations.  
4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.  
5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.  
6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is  
connected to input 200V with the connector for the 100V use being connected.  
7 The output overcurrent protection is effective only for a short circuit.  
PRODUCT IDENTIFICATIONS  
Input and output style  
Terminal block  
Open frame type L-shape frame type  
ECX-002A  
ECX-002D  
ECX-002E  
Connector(Vertical)  
All specifications are subject to change without notice.  
A131_ECX  
(5/21)  
TDK Switching Power Supply  
E SERIES ECX-002  
Dimensions in mm  
SHAPES AND DIMENSIONS  
ECX-002  
M4×8  
110 0.7  
4-M3 Screw tap  
4-ø3.5  
5 0.3  
(5)  
(5.6) 20.4max.  
(for mounting, rear view) (for mounting)  
+
24V  
5V  
output  
+
G
L
input  
N
4-Length of installation screw  
8max.  
4.5 0.4  
119 1  
120 1  
5 0.3  
55 0.4  
UP  
55 0.4  
(5)  
ECX-002D(With frame)  
3-M3  
Screw tap  
(for mounting)  
ECX-002A(Without frame)  
UP  
(
): for reference dimensions mark is in case of without housing type.  
All specifications are subject to change without notice.  
A131_ECX  
(6/21)  
TDK Switching Power Supply  
E SERIES ECX-003  
SPECIFICATIONS AND STANDARDS  
PART NO.  
ECX-003  
Rated output voltage  
and current1  
V1  
V2  
W
5V 1.5A  
24V 1.5A(Peak current 3A)  
43.5[Peak current output: 79.5]  
Maximum output power  
INPUT CONDITIONS  
Input voltage6 Eac  
Input frequency  
Input current  
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)  
Hz  
A
47 to 66[Rating: 50 to 60](Single phase)  
1.5max.[25°C, input and output ratings]  
3[Built-in]  
Fuse rating  
A
Surge current2  
Leakage current  
Efficiency  
A
50max.[25°C, cold start]  
1max.[25°C, input and output ratings]  
77typ.  
mA  
%
OUTPUT CHARACTERISTICS  
Output voltage Edc  
Voltage variable range Edc  
Maximum output current  
Minimum output current  
Input variation  
V
5(V1)  
24(V2)  
V
Fixed  
Fixed  
A
1.5  
1.5(Peak current 3A 10s max.)  
A
0
0
%
1max.  
3.5max. [Within the input voltage range]  
Load variation3  
%
2max.  
5max.  
2max.  
[V2: 10 to 100%]  
4 Total variation 5max.(24V: 10max.)  
Voltage  
stability  
Temperature variation  
%
1max.  
[0 to +40°C]  
Drift  
%
0.5max.  
1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]  
Dynamic load  
Ripple5 Ep-p  
Ripple noise5 Ep-p  
V/ms  
mV  
mV  
s
2.4(Voltage variation)/5(Reset time)[0.3 to 3A sudden load change]  
100max.  
600max.  
800max.  
150max.  
Start up time  
1.5max.(Rise time: 20ms max.)  
20min.  
Normal temperature, input and output ratings,  
load capacitance 100µF max.  
Hold up time  
ms  
AUXILIARY FUNCTIONS  
Indicator display  
No  
V1, V2 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset  
(restart requires roughly 5min wait).  
Overvoltage protection  
Overcurrent protection7  
V1 alone uses voltage lowering. V2 entirely shuts off output upon overcurrent detection or winker operation  
(restart requires roughly 5min wait).  
Remote ON-OFF  
Remote sensing  
Current balance  
STANDARDS  
No  
No  
No  
Safety standards  
Noise terminal voltage  
CONSTRUCTIONS  
External dimensions  
Weight  
mm  
g
30×95×130[H×W×L]  
400max.  
Mounting method  
Case material  
Can be attached to 2 sides.  
Without cover(With frame also available)  
Input and output cables  
1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.  
The V2 peak current should be limited to 10 sec max. and the effective current should be used at the rated current or lower.  
2 A power thermistor is used as a surge current suppressing element.  
3 Determined within a range of 10 to 100% load variations.  
4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.  
5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.  
6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is  
connected to input 200V with the connector for the 100V use being connected.  
7 The output overcurrent protection is effective only for a short circuit.  
PRODUCT IDENTIFICATIONS  
Input and output style  
Terminal block  
L-shape frame type  
ECX-003D  
Connector(Vertical)  
ECX-003E  
All specifications are subject to change without notice.  
A131_ECX  
(7/21)  
TDK Switching Power Supply  
E SERIES ECX-003  
Dimensions in mm  
SHAPES AND DIMENSIONS  
ECX-003  
M4×8  
120 0.7  
4-M3 Screw tap  
5 0.3  
(5)  
(5.6) 25.4max.  
(for mounting, rear view)  
+
24V  
5V  
output  
+
G
L
input  
N
4-Length of installation screw  
8max.  
4.5 0.4  
129 1  
130 1  
5 0.3  
120 0.7  
(5)  
2-M3 Screw tap  
(for mounting)  
ECX-003D(With frame)  
UP  
(
): for reference dimensions  
All specifications are subject to change without notice.  
A131_ECX  
(8/21)  
TDK Switching Power Supply  
E SERIES ECX-004  
SPECIFICATIONS AND STANDARDS  
PART NO.  
ECX-004  
5V 3A  
24V 2A  
63  
Rated output voltage  
and current1  
V1  
V2  
W
Maximum output power  
INPUT CONDITIONS  
Input voltage6 Eac  
Input frequency  
Input current  
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)  
Hz  
A
47 to 66[Rating: 50 to 60](Single phase)  
1.8max.[25°C, input and output ratings]  
3[Built-in]  
Fuse rating  
A
Surge current2  
Leakage current  
Efficiency  
A
50max.[25°C, cold start]  
1max.[25°C, input and output ratings]  
75typ.  
mA  
%
OUTPUT CHARACTERISTICS  
Output voltage Edc  
Voltage variable range Edc  
Maximum output current  
Minimum output current  
Input variation  
V
5(V1)  
Fixed  
3
24(V2)  
Fixed  
2
V
A
A
0
0
%
1max.  
2max.  
1max.  
1max.  
3.5max.  
[Within the input voltage range]  
Load variation3  
%
10, 8max. [V2: 10 to 100%]  
5max. [0 to +40°C]  
4 Total variation 5max.(24V: +15, 10max.)  
Voltage  
stability  
Temperature variation  
%
Drift  
%
5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]  
Dynamic load  
Ripple5 Ep-p  
Ripple noise5 Ep-p  
V/ms  
mV  
mV  
s
100max.  
150max.  
600max.  
800max.  
Start up time  
1.5max.(Rise time: 20ms max.)  
10min.  
Normal temperature, input and output ratings,  
load capacitance 100µF max.  
Hold up time  
ms  
AUXILIARY FUNCTIONS  
Indicator display  
No  
Only V1 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset  
(restart requires roughly 5min wait).  
Overvoltage protection  
Overcurrent protection7  
Remote ON-OFF  
Remote sensing  
Current balance  
STANDARDS  
Upon overcurrent detection, outputs are lowered and winker operates.  
No  
No  
No  
Safety standards  
Noise terminal voltage  
CONSTRUCTIONS  
External dimensions  
Weight  
mm  
g
30×95×130[H×W×L]  
400max.  
Mounting method  
Case material  
Can be attached to 2 sides.  
Without cover(With frame also available)  
Input and output cables  
1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.  
2 A power thermistor is used as a surge current suppressing element.  
3 Determined within a range of 10 to 100% load variations.  
4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.  
5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.  
6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is  
connected to input 200V with the connector for the 100V use being connected.  
7 The output overcurrent protection is effective only for a short circuit.  
PRODUCT IDENTIFICATIONS  
Input and output style  
Terminal block  
L-shape frame type  
ECX-004D  
Connector(Vertical)  
ECX-004E  
All specifications are subject to change without notice.  
A131_ECX  
(9/21)  
TDK Switching Power Supply  
E SERIES ECX-004  
Dimensions in mm  
SHAPES AND DIMENSIONS  
ECX-004  
M4×8  
120 0.7  
4-M3 Screw tap  
(5)  
5 0.3  
(5.6) 25.4max.  
(for mounting, rear view)  
+
24V  
5V  
output  
+
G
L
input  
N
4-Length of installation screw  
8max.  
130 1  
120 0.7  
5 0.3  
(5)  
UP  
2-M3 Screw tap  
(for mounting)  
(
): for reference dimensions  
All specifications are subject to change without notice.  
A131_ECX  
(10/21)  
TDK Switching Power Supply  
E SERIES ECX-005  
SPECIFICATIONS AND STANDARDS  
PART NO.  
ECX-005  
Rated output voltage  
and current1  
V1  
V2  
W
5V 2A  
24V 3A(Peak current 5A)  
82[Peak current output: 130]  
Maximum output power  
INPUT CONDITIONS  
Input voltage6 Eac  
Input frequency  
Input current  
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)  
Hz  
A
47 to 66[Rating: 50 to 60](Single phase)  
2.5max.[25°C, input and output ratings]  
5[Built-in]  
Fuse rating  
A
Surge current2  
Leakage current  
Efficiency  
A
50max.[25°C, cold start]  
1max.[25°C, input and output ratings]  
82typ.  
mA  
%
OUTPUT CHARACTERISTICS  
Output voltage Edc  
Voltage variable range Edc  
Maximum output current  
Minimum output current  
Input variation  
V
5(V1)  
24(V2)  
V
Fixed  
Fixed  
A
2
3(Peak current 5A 10s max.)  
A
0
0
%
1max.  
3.5max. [Within the input voltage range]  
Load variation3  
%
2max.  
8max.  
2max.  
[V2: 10 to 100%]  
4 Total variation 5max.(24V: 10max.)  
Voltage  
stability  
Temperature variation  
%
1max.  
[0 to +40°C]  
Drift  
%
0.5max.  
1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]  
Dynamic load  
Ripple5 Ep-p  
Ripple noise5 Ep-p  
V/ms  
mV  
mV  
s
2.4(Voltage variation)/5(Reset time)[0.5 to 5.0A sudden load change]  
100max.  
600max.  
800max.  
150max.  
Start up time  
1.5max.(Rise time: 20ms max.)  
20min.  
Normal temperature, input and output ratings,  
load capacitance 100µF max.  
Hold up time  
ms  
AUXILIARY FUNCTIONS  
Indicator display  
No  
Only V1 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset  
(restart requires roughly 5min wait).  
Overvoltage protection  
Overcurrent protection7  
Remote ON-OFF  
Remote sensing  
Current balance  
STANDARDS  
Upon overcurrent detection, outputs are lowered and winker operates.  
No  
No  
No  
Safety standards  
Noise terminal voltage  
CONSTRUCTIONS  
External dimensions  
Weight  
mm  
g
30×95×160[H×W×L]  
500max.  
Mounting method  
Case material  
Can be attached to 2 sides.  
Without cover(With frame also available)  
Input and output cables  
1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.  
The V2 peak current should be limited to 10 sec max. and the effective current should be used at the rated current or lower.  
2 A power thermistor is used as a surge current suppressing element.  
3 Determined within a range of 10 to 100% load variations.  
4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.  
5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.  
6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is  
connected to input 200V with the connector for the 100V use being connected.  
7 The output overcurrent protection is effective only for a short circuit.  
PRODUCT IDENTIFICATIONS  
Input and output style  
Terminal block  
L-shape frame type  
ECX-005D  
Connector(Vertical)  
ECX-005E  
All specifications are subject to change without notice.  
A131_ECX  
(11/21)  
TDK Switching Power Supply  
E SERIES ECX-005  
Dimensions in mm  
SHAPES AND DIMENSIONS  
ECX-005  
M4×8  
4-M3 Screw tap  
5 0.3  
150 0.7  
(5)  
(5.6)  
25.4max.  
(for mounting, rear view)  
+
24V  
5V  
output  
+
G
L
input  
N
4-Length of installation screw  
8max.  
160 1  
5 0.3  
150 0.7  
(5)  
2-M3 Screw tap  
(for mounting)  
UP  
(
): for reference dimensions  
All specifications are subject to change without notice.  
A131_ECX  
(12/21)  
TDK Switching Power Supply  
E SERIES ECX-006  
SPECIFICATIONS AND STANDARDS  
PART NO.  
ECX-006  
5V 3A  
24V 3A  
87  
Rated output voltage  
and current1  
V1  
V2  
W
Maximum output power  
INPUT CONDITIONS  
Input voltage6 Eac  
Input frequency  
Input current  
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)  
Hz  
A
47 to 66[Rating: 50 to 60](Single phase)  
2.5max.[25°C, input and output ratings]  
5[Built-in]  
Fuse rating  
A
Surge current2  
Leakage current  
Efficiency  
A
50max.[25°C, cold start]  
1max.[25°C, input and output ratings]  
82typ.  
mA  
%
OUTPUT CHARACTERISTICS  
Output voltage Edc  
Voltage variable range Edc  
Maximum output current  
Minimum output current  
Input variation  
V
5(V1)  
Fixed  
3
24(V2)  
V
Fixed  
A
3
A
0
0
%
1max.  
2max.  
1max.  
0.5max.  
3.5max. [Within the input voltage range]  
Load variation3  
%
8max.  
2max.  
[V2: 10 to 100%]  
4 Total variation 5max.(24V: 10max.)  
Voltage  
stability  
Temperature variation  
%
[0 to +40°C]  
Drift  
%
1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]  
Dynamic load  
Ripple5 Ep-p  
Ripple noise5 Ep-p  
V/ms  
mV  
mV  
s
100max.  
150max.  
600max.  
800max.  
Start up time  
1.5max.(Rise time: 20ms max.)  
20min.  
Normal temperature, input and output ratings,  
load capacitance 100µF max.  
Hold up time  
ms  
AUXILIARY FUNCTIONS  
Indicator display  
No  
Only V1 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset  
(restart requires roughly 5min wait).  
Overvoltage protection  
Overcurrent protection7  
Remote ON-OFF  
Remote sensing  
Current balance  
STANDARDS  
Upon overcurrent detection, outputs are lowered and winker operates.  
No  
No  
No  
Safety standards  
Noise terminal voltage  
CONSTRUCTIONS  
External dimensions  
Weight  
mm  
g
30×95×160[H×W×L]  
500max.  
Mounting method  
Case material  
Can be attached to 2 sides.  
Without cover(With frame also available)  
Input and output cables  
1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.  
2 A power thermistor is used as a surge current suppressing element.  
3 Determined within a range of 10 to 100% load variations.  
4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.  
5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.  
6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is  
connected to input 200V with the connector for the 100V use being connected.  
7 The output overcurrent protection is effective only for a short circuit.  
PRODUCT IDENTIFICATIONS  
Input and output style  
Terminal block  
L-shape frame type  
ECX-006D  
Connector(Vertical)  
ECX-006E  
All specifications are subject to change without notice.  
A131_ECX  
(13/21)  
TDK Switching Power Supply  
E SERIES ECX-006  
Dimensions in mm  
SHAPES AND DIMENSIONS  
ECX-006  
M4×8  
4-M3 Screw tap  
5 0.3  
150 0.7  
(5)  
(5.6) 25.4max.  
(for mounting, rear view)  
+
24V  
5V  
output  
+
G
L
input  
N
4-Length of installation screw  
8max.  
160 1  
5 0.3  
150 0.7  
(5)  
2-M3 Screw tap  
(for mounting)  
UP  
(
): for reference dimensions  
All specifications are subject to change without notice.  
A131_ECX  
(14/21)  
TDK Switching Power Supply  
E SERIES ECX-007  
SPECIFICATIONS AND STANDARDS  
PART NO.  
ECX-007  
Rated output voltage  
and current1  
V1  
V2  
W
5V 3A  
24V 6A(Peak current 10A)  
159[Peak current output: 255]  
Maximum output power  
INPUT CONDITIONS  
Input voltage6 Eac  
Input frequency  
Input current  
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)  
Hz  
A
47 to 66[Rating: 50 to 60](Single phase)  
5max.[25°C, input and output ratings]  
Fuse rating  
A
8[Built-in]  
Surge current2  
Leakage current  
Efficiency  
A
50max.[25°C, input and output ratings.]1st surge current, reset after 30s minimum.  
mA  
%
1max.[25°C, input and output ratings]  
85typ.  
OUTPUT CHARACTERISTICS  
Output voltage Edc  
Voltage variable range Edc  
Maximum output current  
Minimum output current  
Input variation  
V
5(V1)  
24(V2)  
V
Fixed  
Fixed  
A
3
6(Peak current 10A, 10s max.)  
A
0
0
%
1max.  
3.5max. [Within the input voltage range]  
Load variation3  
%
2max.  
8max.  
2max.  
[V2: 10 to 100%]  
4 Total variation 5max.(24V: 10max.)  
Voltage  
stability  
Temperature variation  
%
1max.  
[0 to +40°C]  
Drift  
%
0.5max.  
1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]  
Dynamic load  
Ripple4 Ep-p  
Ripple noise4 Ep-p  
V/ms  
mV  
mV  
s
2.4(Voltage variation)/5(Reset time)[1 to 10A sudden load change]  
100max.  
600max.  
800max.  
150max.  
Start up time  
1.5max.(Rise time: 20ms max.)  
20min.  
Normal temperature, input and output ratings,  
load capacitance 100µF max.  
Hold up time  
ms  
AUXILIARY FUNCTIONS  
Indicator display  
No  
Only V1 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset  
(restart requires roughly 5min wait).  
Overvoltage protection  
Overcurrent protection6  
Remote ON-OFF  
Remote sensing  
Current balance  
STANDARDS  
Upon overcurrent detection, outputs are lowered and winker operates.  
No  
No  
No  
Safety standards  
Noise terminal voltage  
CONSTRUCTIONS  
External dimensions  
Weight  
mm  
g
35×95×220[H×W×L]  
700max.  
Mounting method  
Case material  
Can be attached to 2 sides.  
Frame: Aluminum plating(without cover)  
Input and output cables  
1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.  
The V2 peak current should be limited to 10 sec max. and the effective current should be used at the rated current or lower.  
2 A power thermistor is used as a surge current suppressing element.  
3 Determined within a range of 10 to 100% load variations.  
4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.  
5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.  
6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is  
connected to input 200V with the connector for the 100V use being connected.  
7 The output overcurrent protection is effective only for a short circuit.  
PRODUCT IDENTIFICATIONS  
Input and output style  
Terminal block  
L-shape frame type  
ECX-007D  
Connector(Vertical)  
ECX-007E  
All specifications are subject to change without notice.  
A131_ECX  
(15/21)  
TDK Switching Power Supply  
E SERIES ECX-007  
Dimensions in mm  
SHAPES AND DIMENSIONS  
ECX-007  
M4×8  
4-M3 Screw tap  
5 0.3  
210 0.7  
(5)  
(7.6)  
28.4max.  
(for mounting, rear view)  
+
24V  
5V  
output  
+
G
L
input  
N
4-Length of installation screw  
8max.  
220 1  
5 0.3  
103.5 0.7  
106.5 0.7  
(5)  
4-M3 Screw tap  
(for mounting)  
UP  
15 0.3  
(
): for reference dimensions  
All specifications are subject to change without notice.  
A131_ECX  
(16/21)  
TDK Switching Power Supply  
Characteristics, Functions, and Applications  
BLOCK DIAGRAM  
ECX-001/-003  
G
Surge  
current  
limiting  
circuit  
Input  
filter  
circuit  
Input  
smoothing  
circuit  
+
L
N
Output  
rectifying  
and  
smoothing  
circuit  
V2:24V  
100V/200V  
Change-over  
connector  
Over-  
Power  
switching  
circuit  
+
Output  
rectifying  
and  
smoothing  
circuit  
current  
detection  
circuit  
V1:5V  
Series  
regulator  
Voltage detection  
circuit  
Control  
circuit  
Control  
circuit  
V1 and V2 outputs are floating.  
ECX-002/-004  
G
Surge  
current  
limiting  
circuit  
Input  
smoothing  
circuit  
Output rectifying  
and  
smoothing circuit  
Input  
filter  
circuit  
+
L
N
V2:24V  
V1:5V  
100V/200V  
Over-  
Power  
switching  
circuit  
current  
detection  
circuit  
Change-over  
connector  
Output rectifying  
and  
smoothing circuit  
+
Overcurrent  
detection  
circuit  
Control  
circuit  
Control  
circuit  
Over-  
voltage  
detection  
circuit  
V1 and V2 outputs are floating.  
All specifications are subject to change without notice.  
A131_ECX  
(17/21)  
TDK Switching Power Supply  
Characteristics, Functions, and Applications  
ECX-005/-006/-007  
G
Surge  
current  
limiting  
circuit  
Input  
smoothing  
circuit  
Output rectifying  
and  
smoothing circuit  
Input  
filter  
circuit  
+
L
N
V2:24V  
100V/200V  
Over-  
Power  
switching  
circuit  
Change-over  
connector  
current  
detection  
circuit  
Output rectifying  
and  
smoothing circuit  
+
V1:5V  
Overcurrent  
detection  
circuit  
Control  
circuit  
Control  
circuit  
Over-  
V1 and V2 outputs are floating.  
voltage  
detection  
circuit  
COMMON SPECIFICATIONS  
Temperature and humidity  
Operating(°C)  
Storage(°C)  
0 to +60 Derating is necessary when operating environment temperature exceed 40°C  
25 to +75  
.
Temperature range  
Operating(%)RH  
Storage(%)RH  
Humidity range  
20 to 95[Maximum wet-bulb temperature: 35°C, without dewing]  
Amplitude and vibration  
5 to 10Hz  
All amplitude 10mm[3 directions, each 1h]  
Acceleration 39.2m/s2[4G, 3 directions, horizontal installation, each 1h]  
Amplitude  
10 to 200Hz  
Acceleration 19.6m/s2[2G, 3 directions, vertical installation, each 1h]  
Acceleration  
392m/s2[40G, 3 directions, each 3 times]  
11 5ms  
Vibration  
Vibration time  
Withstand voltage and insulation resistance  
Input terminal to ground terminal(  
Input terminal to output terminal  
Input terminal to ground terminal(  
Input terminal to output terminal  
)
Eac(kV)1.5, 1min[Normal temperature, normal humidity, cutout current 10mA]  
Eac(kV)2, 1min[Normal temperature, normal humidity, cutout current 10mA]  
G
Withstand voltage  
)
G
Insulation resistance  
Edc(V)500, 100Mmin. [Normal temperature, normal humidity]  
Output terminal to ground terminal(  
)
G
All specifications are subject to change without notice.  
A131_ECX  
(18/21)  
TDK Switching Power Supply  
Characteristics, Functions, and Applications  
TERMINAL DESIGNATIONS AND FUNCTIONS  
ECX-001/002  
1
AC input terminals(L, N)  
Connected to either the  
AC.100V or 200V single-phase  
line. The delivery setting is  
200V. Before use with these  
terminals connected to 100V,  
connect the attached connector  
to CP2.  
1
2
3
4
5
6
7
1
3
5
24V+  
24V+  
24V–  
NC  
4
5
3
+
1
24V  
5V  
4
2
3
4
5
6
7
4
5
3
Reference:  
Corresponding housing  
XHP-7(JST)  
Corresponding contact  
SXH-001T-P0.6  
+
Output  
connector  
3
2
1
5V+  
5V–  
5V–  
G
2
3
4
5
6
Frame ground terminal(G)  
Connect to earth ground.  
1
3
5
2
1
G
L
DC output terminals(5V, +, –)  
Connect to load.  
Reference:  
Corresponding housing  
VHR5N(JST)  
Corresponding contact  
SVH-21T-P1.1  
2
1
DC output terminals(24V, +, –)  
Connect to load.  
N
Input  
connector  
L
CP2  
No connection(NC)  
Connect none to this terminal.  
N
Input switching connector  
6
(CP2)  
For use in switching AC input  
voltages.  
Without CP2 connector: For  
200V use  
With CP2 connector: For 100V  
use  
ECX-003/004/005/006  
1
AC input terminals(L, N)  
Connected to either the  
AC.100V or 200V single-phase  
line. The delivery setting is  
200V. Before use with these  
terminals connected to 100V,  
connect the attached connector  
to CP2.  
1
2
3
4
5
6
1
3
5
24V+  
24V+  
4
3
+
+
Reference:  
1
24V  
5V  
4
2
3
4
5
6
4
3
24VCorresponding housing  
Output  
connector  
VHR-6N(JST)  
Corresponding contact  
SVH-21T-P1.1  
5V+  
5V–  
5V–  
G
3
2
1
2
3
4
5
Frame ground terminal(G)  
Connect to earth ground.  
1
3
5
2
1
G
L
DC output terminals(5V, +, –)  
Connect to load.  
Reference:  
Corresponding housing  
VHR-5N(JST)  
Corresponding contact  
SVH-21T-P1.1  
2
1
Input  
connector  
L
DC output terminals(24V, +, –)  
Connect to load.  
N
N
Input switching connector  
(CP2)  
For use in switching AC input  
voltages.  
5
Without CP2 connector: For  
200V use  
With CP2 connector: For 100V  
use  
All specifications are subject to change without notice.  
A131_ECX  
(19/21)  
TDK Switching Power Supply  
Characteristics, Functions, and Applications  
ECX-007  
+
+
1
2
3
4
5
6
7
24V  
5V  
4
4
3
3
2
1
1
3
5
2
1
G
L
N
5
CP2  
1
AC input terminals(L, N)  
1
2
3
4
5
6
7
1
3
5
24V+  
24V+  
24V–  
24V–  
5V+  
5V–  
5V–  
G
Connected to either the AC.100V or 200V single-  
phase line. The delivery setting is 200V. Before use  
with these terminals connected to 100V, connect the  
attached connector to CP2.  
4
Reference:  
Corresponding housing  
VHR-7N(JST)  
Corresponding contact  
SVH-21T-P1.1  
Output  
connector  
2
3
4
5
Frame ground terminal(G)  
Connect to earth ground.  
DC output terminals(5V, +, –)  
Connect to load.  
3
DC output terminals(24V, +, –)  
Connect to load.  
Input switching connector(CP2)  
For use in switching AC input voltages.  
Without CP2 connector: For 200V use  
With CP2 connector: For 100V use  
Reference:  
Corresponding housing  
VHR-5N(JST)  
Corresponding contact  
Corresponding contact  
2
1
Input  
connector  
L
N
OUTPUT POWER-AMBIENT TEMPERATURE(DERATINGS)  
INPUT SURGE CURRENT, START UP TIME AND HOLD UP  
TIME  
Example: ECX-001  
Input voltage: AC.100V  
Load: Rating  
100  
80  
75  
Temperature: 25°C  
ECX-007 causes a second peak.  
60  
50  
Input surge current  
15A(30A at 200V)  
40  
Available operating range  
(outside of warranty)  
20  
10  
0
10  
20  
30  
40  
50  
60  
24V output  
Input ON  
Ambient temperature(°C)  
5V output  
10ms  
Rise time  
Start up time 750ms  
37 to 42ms  
15 to 20ms  
Fall time  
Hold up time  
All specifications are subject to change without notice.  
A131_ECX  
(20/21)  
TDK Switching Power Supply  
Characteristics, Functions, and Applications  
OUTPUT CHARACTERISTICS(TYPICAL EXAMPLE SHOWN  
BELOW.)  
ECX-001(24V)[25°C, INPUT AND OUTPUT RATINGS]  
ECX-001(5V)[25°C, INPUT AND OUTPUT RATINGS]  
6
28  
26  
24  
22  
20  
5V/1A  
5V/0A  
24V=1A  
5V/0A  
5
24V=0A  
4
5V/1A  
3
2
1
0
10  
0
1
2
3
1
2
3
4
Output current(A)  
Output current(A)  
ECX-007(24V)[25°C, INPUT AND OUTPUT RATINGS]  
ECX-007(5V)[25°C, INPUT AND OUTPUT RATINGS]  
6
28  
26  
24  
22  
20  
5V/3A  
24V=0A  
5
24V=6A  
4
5V/0A  
3
2
1
0
10  
0
1
5
6
10  
1
2
3
4
5
6
Output current(A)  
Output current(A)  
DYNAMIC LOAD(TYPICAL EXAMPLE SHOWN BELOW.)  
ECX-001[AC: 100V, 25°C]  
ECX-007[AC: 100V, 25°C]  
(1.5A)  
(10A)  
Current(0A)  
Current(0A)  
Voltage  
Voltage  
V:0.5V/DIV, 1A/DIV(01.5A) H:5ms/DIV  
5V1A  
V:1V/DIV, 5A/DIV(010A) H:2ms/DIV  
5V3A  
All specifications are subject to change without notice.  
A131_ECX  
(21/21)  
TDK Switching Power Supply  
Characteristics, Functions, and Applications  
ABOUT 24V (V2) OUTPUT PEAK CURRENT  
INPUT VOLTAGE  
The ECX-001, ECX-003, ECX-005, and ECX-007 are capable of  
flowing peak current as 24V load current for driving mechatronics.  
The values exceeding the continuous rated values, however,  
The output of the power supply may shut down upon a  
continuous input of 30% to 50% of the input rated voltage applied  
for approx. 1 sec or longer. Output recovers by reentry of an input  
(approx. 5 min. needed before the reentry of the input).  
must fulfill the following conditions.  
I1  
TONE GENERATION  
A little tone may be generated in an unloaded condition for all  
outputs. It is, however, not an abnormal condition.  
I2  
INPUT FILTER  
The power supply has an input line filter mounted inside in order  
to reduce external noise or to prevent a noise generated inside  
the power supply from adversely affecting external electronic  
equipment. Ground wiring is recommended for the G terminal  
(frame) in order to enhance the filter effect. If a further noise  
reduction is required, attach a filter to a portion outside the power  
supply.  
t
T
D=(t/T)  
1 Condition of time  
10s  
3 Conditions of effective current  
t
2
2
2
2
2
DI1 +(ID)I2  
1A(ECX-001)  
1.5A(ECX-003)  
3A(ECX-005)  
6A(ECX-007)  
2 Conditions of current value  
I1 1.5A(ECX-001)  
I1 3A(ECX-003)  
2
DI1 +(ID)I2  
2
DI1 +(ID)I2  
2
DI1 +(ID)I2  
I1 5A(ECX-005)  
LEAKAGE CURRENT  
I1 10A(ECX-007)  
Leakage current flows between the G terminal (frame) and the  
ground. If two or more power supplies are used or a filter is  
attached to an external portion, the total leakage current is  
applied.  
NOTES ON USE  
INTERNAL ADJUSTMENT TRIMMER  
This product has an internal adjustment trimmer. Please do not  
touch it that can result in damage caused by any change of the  
setting.  
RIPPLE NOISE MEASUREMENT  
Measure the ripple noise as shown below.  
C1, C2 : 0.1µF  
: Film capacitor  
C3: 100µF  
: Electrolytic capacitor  
Approx.15cm  
OVERCURRENT PROTECTION FUNCTION  
The output overcurrent protection is effective only for a short  
circuit. A continuation of the intermediate overload condition (for  
example, if the condition continues for a time period exceeding  
the standard at the peak current value) may cause a damage on  
the product.  
+
Power  
supply  
R1: 50resistor  
Input  
Output C3 C2  
Load  
50coaxial cable  
R1  
C1  
HANDLING PRODUCT BEING ENERGIZED (INCLUDING  
IMMEDIATELY AFTER BEING ENERGIZED)  
Oscilloscope band  
width<50MHz  
There are some high-temperature or high-voltage portions inside  
the power supply being energized (or immediately after being  
energized). Be careful to touch internal components. In addition,  
energizing at light load may leave a high voltage for several  
minutes after a shutdown of the input voltage.  
MAINTENANCE SERVICE  
In case of a trouble, do not make any adjustment on the inside of  
the power supply. Otherwise, the product may not be guaranteed.  
In case of a trouble in the product, please return it to us through a  
purchasing route. If there are any unclear points for use of the  
power supply, please contact us.  
POWER SUPPLY INSTALLATION METHOD  
For installation with frame  
A vertical installation  
OTHERS  
Frame  
B horizontal installation  
.
1 Unless conditions are otherwise specified in the specifications  
Cabinet  
or standards, 25°C and rated input-output should be applied.  
2. Surface treated steel sheets are used for a frame and a part of  
a radiator in this product. Although rust may be gathered on  
their cross sections, they can be used as they are. Note that,  
however, the product should be put in for repair in case of a  
significant deterioration of the rust or a damaged insulation  
1. For an open frame type, use spacers or the like to make a clearance from the  
cabinet. In using non-insulated spacers, use ones having a 6mm external  
diameter.  
2. The vibration, shock, and conditions depend upon the power supply  
installation method. For details, refer to descriptions of the corresponding  
items.  
property because of a use bad environments.  
A131_ECX  
020826  
All specifications are subject to change without notice.  

相关型号:

ECX-003

AC-DC Regulated Power Supply Module, 2 Output, 43.5W,
TDK

ECX-003D

AC-DC Regulated Power Supply Module, 2 Output, 44W, 130 X 95 MM, 30 MM HEIGHT, MODULE
TDK

ECX-004

AC-DC Regulated Power Supply Module, 2 Output, 63W, 130 X 95 MM, 30 MM HEIGHT, MODULE
TDK

ECX-004E

AC-DC Regulated Power Supply Module, 2 Output, 63W, 130 X 95 MM, 30 MM HEIGHT, MODULE
TDK

ECX-005

AC-DC Regulated Power Supply Module, 2 Output, 82W, 160 X 95 MM, 30 MM HEIGHT, MODULE
TDK

ECX-005D

AC-DC Regulated Power Supply Module, 2 Output, 82W, 160 X 95 MM, 30 MM HEIGHT, MODULE
TDK

ECX-005F

AC-DC Regulated Power Supply Module, 2 Output, 82W, 160 X 95 MM, 30 MM HEIGHT, MODULE
TDK

ECX-006

AC-DC Regulated Power Supply Module, 2 Output, 87W, 160 X 95 MM, 30 MM HEIGHT, MODULE
TDK

ECX-006D

AC-DC Regulated Power Supply Module, 2 Output, 87W, 160 X 95 MM, 30 MM HEIGHT, MODULE
TDK

ECX-007

AC-DC Regulated Power Supply Module, 2 Output, 159W, 220 X 95 MM, 35 MM HEIGHT, MODULE
TDK

ECX-007F

AC-DC Regulated Power Supply Module, 2 Output, 159W, 220 X 95 MM, 35 MM HEIGHT, MODULE
TDK

ECX-1084-20.480M

CRYSTALS 50/100 SERIES 0+70 25 20.480MHZ FUND HC-49/U HC-49/U
ECLIPTEK