RGC4W300W008A-003 [TDK]
DC-DC开关电源;型号: | RGC4W300W008A-003 |
厂家: | TDK ELECTRONICS |
描述: | DC-DC开关电源 开关 |
文件: | 总6页 (文件大小:1929K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
RGC Series
http://product.tdk.com/en/power/rgc
www.emea.lambda.tdk.com/rgc
300W, 9 to 53V Input Non-Isolated
Ruggedized DC-DC Buck-Boost Converters
The rugged RGC non-isolated DC-DC step-up and step-down converters are encapsulated in a five-sided aluminum case and rated for up to 115°C
operation. The modules have the industry standard 1/16th brick pin-out, are qualified to MIL-STD-810G (shock and vibration) and designed for fan-less,
conduction cooled applications. The series accepts a wide input range to support multiple DC bus and battery voltages. Standard features include remote
on/off, remote sense and output trim while a full feature adds power good, frequency synchronization and output current monitoring, making the modules a
truly versatile board mount power solution. The wide output adjustment range allows one model to be used in multiple positions, assisting inventory and part
number reduction.
Features
Benefits
• Up to 300W in a 1/16th Brick-Pin-Out
• Encapsulated in a 5-sided Aluminum case
• 115°C maximum case temperature
• Efficiency - Up to 97%
• High Power Density, Less Board Area Needed
• Improves EMI
• Rugged deployment in harsh environment with high shock & vibration exposure
• Longer Battery Life / Low Power Consumed
• One Part Supports Multiple System Voltages
• Can Operate from Different DC Input Source Voltages
• Extends run times on battery-powered equipment
• Wide Output Adjustment from 5 up to 48V
• Wide Input Range from 9 to 53V
• Buck-Boost - maintains output regulation even when input varies
Model Selector
Input
Voltage
(V)
Output
Voltage
(V)
Max
Current
(A)
Max
Power
(W)
Negative
Logic
On/Off
Model
Feature
Set
RGC4W300W008A-001
RGC4W300W008A-003
RGC4W300W012A-001
RGC4W300W012A-003
9 - 53
9 - 53
9 - 53
9 - 53
9.6 - 48
9.6 - 48
5.0 - 28
5.0 - 28
8
8
12.5
12.5
300
300
300
300
Yes
Yes
Yes
Yes
Standard
Full
Standard
Full
Contact factory for other upcoming part number suffix options.
Related Products
Type
Part Number(s)
Size (mm) / Description
Ruggedized DC-DC Buck Converter
DC-DC Buck-Boost Converter
DC-DC Buck Converter
DC-DC Buck Converter
Isolated DC-DC Converter
Non-Isolated DC-DC Converter
Non-Isolated DC-DC Converter
Input Filter
RGA
250W, Input 9-40V and Output 3.3-24V or, 9-53V Input and 3.3V up to 40V Output
300W, Input 9-53V or 9-36V, Output 9.6-48V 8A, 5-28V 12.5A or 8-24V 20A
500-750W, Input 18-60V or 18-32V, Output 3.3-24V 33A or 3.3-18V 45A
250W, Input 9 -53V, Output 3.3-40V 10A or 3.3-15V 20A
120W Industrial, Input 9-36V, Isolated Quarter Brick
i7C
i7A
i6A4W
GQA
iBH
80W/20A, 3.5-14Vin, 0.7 - 5.5Vout, DOSA Compatible
iCH
85W/12A, 4.5-14Vin, 0.7 - 8.5Vout, DOSA Compatible
iDQ
75V / 10A Filter
Evaluation Board
i7X-C01-EVK-S0
Evaluation board with no module. Order required RGC part number separately.
1
RGC Series
Specifications
Model
RGC4W300W008A
RGC4W300W012A
Input
Input Voltage Range
Input Current (max)
Standby Input Current
No Load Input Current
Turn-ON Input Voltage
Turn-OFF Input Voltage
Efficiency (typ)
Vdc
A
9 - 53
25
mA
mA
Vdc
Vdc
%
0.25
5
9.5
8.5
93 - 97%
91 - 96%
Safety Certifications and Markings
Output
-
CE, UKCA Mark
Output Voltage Initial Setpoint
Output Voltage Tolerance
Line Regulation
%
%
%
%
±2.5
±4.0
0.8
±2.5
±4.0
0.8
Load Regulation
0.5
0.8
(step-down)
(step-up)
60
100
350
Ripple & Noise(2)
mVpp
300
External Load Capacitance
Switching Frequency
uF
kHz
A
330 - 3000
250
Overcurrent Protection Threshold (typ)
Overtemperature Protection
Output Voltage Adjustment Range
Remote Sense
15
17
°C
130 case, shutdown - autorecovery
See full specification for output trim equation.
(+) Sense, compensating up to 5% of output voltage
Negative Logic
Remove On/Off
Frequency Synchronization
Current Monitoring (Imon)
Environmental
Operating Temperature (Tcase)
Storage Temperature
Humidity (non condensing)
Altitude(3)
See full specifications
See full specifications
°C
°C
%RH
m
-40 to 115
-55 to 125
10 - 95
2000
Cooling
-
Conduction Cooling
Shock
-
MIL-STD-810G 516.6 Procedure I & IV
MIL-STD-810G 514.6 Procedure I, Cat 10
Qualified to 700 cycles / -40 to 125°C, 60°C/minute ramp, 30minute dwell time
Vibration
Thermal Cycling Test (TCT)
Other
Weight (max)
g
68.1
38.1 x 49.5 x 13.0
Size (LxWxH)
Size (LxWxH)
mm
38.1 x 39.4 x 13.0 (Mounting tab excluded)
1.50 x 1.95 x 0.51
Inches
1.50 x 1.55 x 0.51 (Mounting tab excluded)
MTBF - Telcordia SR-332 (100% Load, 40°C) MHrs
Warranty yrs
Notes
(1) See website for detailed product specifications.
> 10
3
(2) Measured with one 330 μF electrolytic and one 22 μF ceramic capacitors, BW = 20MHz.
(3) Contact Technical Support for operation at higher altitudes.
2
RGC Series
Operating Range (RGC4W300W008A-001)
Operating Range (RGC4W300W012A-001)
*
*
*
3
RGC Series
Typical Thermal Derating (RGC4W300W008A-001)
Typical Thermal Derating (RGC4W300W012A-001)
*
Typical Application Circuit
Recommendation
1. Cin/Cout MLCC should be connected to the RGC module as close as possible in order to reject high frequency noise.
2. Connect Vin(-) and Vout(-) to copper ground plane underneath the RGC module.
3. TRIM resistor “Rup” should be connected to the RGC module as close as possible.
4. SYNC must be connected to GND when not in use.
5. External R-C filter should be present when using Current Monitor.
4
RGC Series
Mechanical Specification
Note: Case is not connected to ground (floating).
Recommended PCB Hole Pattern
Pinout
PIN
1
Function
VIN(+)
PIN
6
Function
TRIM
2
ON / OFF
7
SENSE (+)
3
VIN (-) / GND
VOUT (-) / GND
PWR GOOD (Option)
8
VOUT (+)
4
32
34
Sync (Option)
5
Current Monitor / Imon (Option)
Pin base material is brass or copper with gold over nickel plating.
5
RGC Series
TDK-Lambda France SAS
TDK-Lambda Americas
Tel: +33 1 60 12 71 65
Tel: +1 800-LAMBDA-4 or 1-800-526-2324
tla.powersolutions@tdk.com
www.us.lambda.tdk.com
tlf.fr.powersolutions@tdk.com
www.emea.lambda.tdk.com/fr
Italy Sales Office
Tel: +39 02 61 29 38 63
tlf.it.powersolutions@tdk.com
www.emea.lambda.tdk.com/it
TDK Electronics do Brasil Ltda
Tel: +55 11 3289-9599
sales.br@tdk-electronics.tdk.com
www.tdk-electronics.tdk.com/en
Netherlands
tlf.nl.powersolutions@tdk.com
www.emea.lambda.tdk.com/nl
TDK-Lambda Germany GmbH
Tel: +49 7841 666 0
tlg.powersolutions@tdk.com
TDK-Lambda Corporation
Tel: +81-3-6778-1113
www.jp.lambda.tdk.com
www.emea.lambda.tdk.com/de
TDK-Lambda (China) Electronics Co. Ltd.
Tel: +86 21 6485-0777
tlc.powersolutions@tdk.com
www.lambda.tdk.com.cn
Austria Sales Office
Tel: +43 2256 655 84
tlg.at.powersolutions@tdk.com
TDK-Lambda Singapore Pte Ltd.
Tel: +65 6251 7211
tls.marketing@tdk.com
www.sg.lambda.tdk.com
www.emea.lambda.tdk.com/at
Switzerland Sales Office
Tel: +41 44 850 53 53
tlg.ch.powersolutions@tdk.com
www.emea.lambda.tdk.com/ch
TDK India Private Limited, Power Supply Division
Tel: +91 80 4039-0660
mathew.philip@tdk.com
www.sg.lambda.tdk.com
Nordic Sales Office
Tel: +45 8853 8086
tlg.dk.powersolutions@tdk.com
www.emea.lambda.tdk.com/dk
TDK-Lambda UK Ltd.
Tel: +44 (0) 12 71 85 66 66
tlu.powersolutions@tdk.com
www.emea.lambda.tdk.com/uk
TDK-Lambda Ltd.
Tel: +9 723 902 4333
tli.powersolutions@tdk.com
www.emea.lambda.tdk.com/il-en
For Additional Information, please visit
https://product.tdk.com/en/power/
RGC_260962_March 2nd, 2023 V2
6
RGC Series
相关型号:
©2020 ICPDF网 联系我们和版权申明