描述:

Small Form- Factor Pluggable (SFP) Seating

文件: 总4页 (文件大小:115K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Instruction Sheet  
Small Form-Factor Pluggable (SFP)+ Seating  
Tool Kits 2018280-[ ] for  
Stacked PT Connector and Cage Assemblies  
408-10261  
10 NOV 11 Rev C  
Seating Tool Kit 2018280 -1 Shown  
Back  
Seating Tool Bottomed  
on Cage Assembly  
2¢1 SFP+ Stacked PT  
Connector and Cage  
Assembly (With Gasket)  
2007538-1 (Shown)  
Wall Support  
(For Clarity, Shown  
Not Installed)  
Press-Fit  
Contact  
SFP+ CONNECTOR  
AND CAGE ASSEMBLY  
CONFIGURATION  
SEATING TOOL  
KIT  
2018280--1  
2018280--2  
2018280--3  
2018280--4  
2018280--5  
2018280--6  
2¢1  
2¢2  
2¢4  
2¢6  
2¢8  
2¢5  
Printed Circuit (PC)  
Board (Ref)  
PC Board Support  
Fixture (Ref)  
Figure 1  
support must be installed into the port(s) of the cage  
assembly.  
1. INTRODUCTION  
SFP+ Seating Tool Kits 2018280--[ ] are used to seat  
the SFP+ stacked PT connector and cage assembly  
configurations given in Figure 1 onto the pc board.  
The connector and cage assemblies contain press--fit  
contacts to allow solderless pc board installation.  
Read these instructions thoroughly before using the  
seating tool kit.  
The top of the seating tool provides a surface to  
accept the force applied by the application tool to seat  
the connector and cage assembly onto the pc board.  
During seating, the back and sides of the seating tool  
protect the connector and cage assembly from  
damage. The wall support supports the individual  
port(s) of the cage assembly to prevent the cage  
assembly from collapsing.  
Dimensions on this sheet are in metric units [with  
U.S. customary units in brackets]. Figures are not  
drawn to scale.  
NOTE  
3. REQUIREMENTS  
i
3.1. PC Board Support Fixture (Customer Supplied)  
A pc board support must be used to provide proper  
support for the pc board and to protect the pc board  
and product from damage. The support fixture must  
be designed for specific needs using the following  
recommendations:  
2. DESCRIPTION (See Figure 1)  
Each seating tool kit consists of a seating tool and a  
wall support. The seating tool and wall support are  
also available separately. The seating tool has cutouts  
(two located on each side) to accept the protruding  
part of the standoffs of the cage assembly. The wall  
S it should be at least 25.4 mm [1 in.] longer and  
wider than the pc board.  
E2011 Tyco Electronics Corporation, a TE Connectivity Ltd. Company  
TOOLING ASSISTANCE CENTER 1--800--722--1111 This controlled document is subject to change.  
1 of 4  
All Rights Reserved  
PRODUCT INFORMATION 1--800--522--6752  
For latest revision and Regional Customer Service,  
visit our website at www.te.com  
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks.  
*Trademark. Other logos, product and/or Company names may be trademarks of their respective owners.  
LOC B  
408-10261  
S it should have flat surfaces with holes or a  
channel large enough and deep enough to  
receive any protruding components of the  
connector and cage assembly and to prevent  
the pc board from bowing.  
S the wall support must be properly installed, and  
the seating tool, connector and cage assembly,  
and application tool ram must be properly  
aligned before cycling the application tool  
1. Set tool seating height to the dimension shown  
in Figure 2 (application tool shut height will equal  
the tool seating height PLUS the combined  
thicknesses of the pc board and support fixture).  
After seating, a gap of no more than 0.10 mm  
[.004 in.] between the cage assembly standoffs  
and the pc board is allowed.  
3.2. Application Tool  
Power for seating tools must be provided by an  
application tool (with a ram) capable of supplying a  
downward force of 44.5 N [10 lb--force] per contact.  
Manual Arbor Frame Assembly 58024--1 is available  
for use with these seating tool kits. Refer to  
Instruction Sheet 408--6923 for operating procedure.  
Use the tool seating height as a reference  
starting point. This height may need to be  
adjusted to obtain the amount allowed (maximum  
of 0.10 mm [.004 in.]) between the standoffs of  
the cage assembly and the pc board.  
NOTE  
Over -driving of the connector and cage assembly  
will deform parts critical to the quality of the  
connection. Maximum force occurs prior to the  
connector and cage assembly bottoming on the  
pc board.  
CAUTION  
i
!
2. Slide the wall support into the port(s) of the cage  
assembly until the wall support is secure.  
4. SETUP  
5. SEATING (Figure 2)  
When setting up equipment to seat the connector and  
cage assembly, pay particular attention to the  
following:  
1. Place the pc board on the support fixture.  
2. Orient the seating tool over the cage assembly  
so that the back is aligned with the back of the  
cage assembly. Then lower the seating tool onto  
the cage assembly, making sure that the cutouts  
slide over the protruding components of the cage  
assembly, until the seating tool bottoms on the top  
of the cage assembly.  
S the seating tool must be matched to the  
connector and cage assembly  
If the seating tool and connector and cage  
assembly are mismatched or are improperly  
aligned, damage could occur to the tooling,  
connector and cage assembly, or both.  
CAUTION  
!
Note: Not to Scale  
Ram of Application Tool  
(Fully Down)  
Seating Tool (2018280-1 Shown)  
Cage Assembly  
A
(See Table)  
Wall Support (Installed in  
Ports of Cage Assembly)  
Application Tool  
Shut Height  
(Ram Fully Down)  
(See Section 4, Step 1)  
B
Press-Fit Contacts (and Any  
Protruding Components) Inserted  
into Holes in PC Board and  
PC Board Support Fixture  
(See Table)  
0.10 mm [.004 in.]  
(Max) Gap Allowed  
PC Board  
PC Board Support Fixture  
DIMENSION A  
TOOL SEATING HEIGHTD  
DIMENSION B  
CAGE ASSEMBLY SEATING HEIGHTD  
40.64 mm [1.60 in.]  
25.5 mm [1.004 in.]  
D With Connector and Cage Assembly Seated  
Figure 2  
2 of 4  
Rev C  
408-10261  
3. Place the connector and cage assembly on the  
pc board so that the contacts and alignment posts  
are aligned and started into the matching holes in  
the pc board.  
6.1. Daily Maintenance  
It is recommended that each operator be made aware  
of, and responsible for, the following steps of daily  
maintenance.  
4. Center the seating tool (with the connector and  
cage assembly) under the ram of the application  
tool. Slowly lower the ram until it just meets the  
seating tool. Verify alignment of pc board support,  
pc board, connector and cage assembly, and  
seating tool.  
1. Remove dust, moisture, and contaminants with  
a clean, soft brush or a lint--free cloth. DO NOT  
use objects that could damage the components.  
2. When the seating tool and wall support are not  
in use, store them in a clean, dry area.  
Damage to the pc board, seating tool, or  
connector and cage assembly may occur if the  
seating tool is not properly seated on the  
connector and cage assembly before cycling the  
application tool.  
CAUTION  
6.2. Periodic Inspection  
Regular inspections should be performed by quality  
control personnel. A record of scheduled inspections  
should remain with the seating tool or be supplied to  
personnel responsible for the seating tool kit.  
Inspection frequency should be based on amount of  
use, working conditions, operator training and skill,  
and established standards.  
!
5. Cycle the application tool to seat the connector  
and cage assembly on the pc board. Then retract  
the ram, and carefully remove the seating tool by  
pulling it straight from the cage assembly.  
6. Remove the wall support from the cage  
assembly.  
7. REPLACEMENT AND REPAIR  
Customer--replaceable parts are listed in Figure 3.  
A complete inventory should be stocked and  
controlled to prevent lost time when replacement of  
parts is necessary. Parts other than those listed  
should be replaced by TE Connectivity to ensure  
quality and reliability. Order replacement parts  
through your representative, or call 1--800--526--5142,  
or send a facsimile of your purchase order to  
717--986--7605, or write to:  
7. Check the connector and cage assembly for  
proper seating according to the following:  
a. the widest section of each compliant pin is  
inside its intended pc board hole  
b. each alignment post is in its intended pc  
board hole  
c. the connector and cage assembly is seated  
on the pc board with a seating height—  
measured from the top of the cage assembly  
(not including the springs or elastomeric gasket)  
to the top of the pc board— given in Figure 2  
CUSTOMER SERVICE (038--035)  
TYCO ELECTRONICS CORPORATION  
PO BOX 3608  
HARRISBURG PA 17105--3608  
d. if present, the gap between the standoffs and  
the pc board is no more than 0.10 mm [.004 in.]  
8. REVISION SUMMARY  
For detailed application requirements of the  
connector and cage assembly, refer to the  
relative application specification.  
NOTE  
S Updated document to corporate requirements  
S Added new part numbers to tables in Figures 1  
i
and 3  
6. MAINTENANCE AND INSPECTION  
The seating tool is assembled and inspected before  
shipment. It is recommended that the seating tool be  
inspected immediately upon arrival at your facility to  
ensure that it has not been damaged during  
shipment, and that it conforms to the dimensions  
provided in Figure 3.  
Rev C  
3 of 4  
408-10261  
Seating Tool  
(2¢4 Shown)  
1
Wall Support  
(2¢4 Shown)  
2
A
E
F
D
B
C
REPLACEMENT PARTS  
PART NUMBER FOR KIT (By Cage Assembly Configuration)  
QTY PER  
KIT  
ITEM  
2¢1  
2¢2  
2¢4  
2¢6  
2¢8  
2¢ 5  
1
2
2018296--1  
2018289--1  
2018295--1  
2018286--1  
2018294--1  
2018284--1  
2018297--1  
2018292--1  
2018798--1  
2018801--1  
2018802--1  
2018805--1  
1
1
KIT  
DIMENSION (mm [in.])  
(By Cage Assembly  
Configuration)  
A
B
C
D
E
F
2¢1  
2¢2  
2¢4  
2¢6  
2¢8  
2¢5  
17.93 [.706]  
32.16 [1.266]  
60.69 [2.389]  
89.18 [3.511]  
117.70 [4.634]  
74.93 [2.950]  
13.64 [.537]  
27.89 [1.098]  
56.39 [2.220]  
84.89 [3.342]  
113.28 [4.460]  
70.61 [2.780]  
59.00 [2.323]  
32.38 [1.275]  
Figure 3  
50.80 [2.00]  
24.26 [.955]  
4 of 4  
Rev C  

相关型号:

2018280--3

Small Form- Factor Pluggable (SFP) Seating
TE

2018280--4

Small Form- Factor Pluggable (SFP) Seating
TE

2018280--5

Small Form- Factor Pluggable (SFP) Seating
TE

2018280--6

Small Form- Factor Pluggable (SFP) Seating
TE

2018280-1

Stacked Small Form-Factor Pluggable
TE

2018280-2

Stacked Small Form-Factor Pluggable
TE

2018280-3

Stacked Small Form-Factor Pluggable
TE

2018280-4

Stacked Small Form-Factor Pluggable
TE

2018280-5

Stacked Small Form-Factor Pluggable
TE

2018280-6

Stacked Small Form-Factor Pluggable
TE

20183

Other AC and DC Meters Available
HONEYWELL

2018377

Impact™ Backplane Connector System
TE