3EGG1C-2 [TE]

Smallest Power Entry Module with Metric Fuse Holders; 与公制保险丝座最小的电源输入模块
3EGG1C-2
型号: 3EGG1C-2
厂家: TE CONNECTIVITY    TE CONNECTIVITY
描述:

Smallest Power Entry Module with Metric Fuse Holders
与公制保险丝座最小的电源输入模块

连接器 电源连接器
文件: 总3页 (文件大小:282K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Catalog: 1654001  
Issue Date: 06.2011  
Corcom Product Guide  
Smallest Power Entry Module with Metric Fuse Holders  
GG & HG Series  
UL Recognized  
CSA Certified  
VDE Approved  
GG1  
GG8  
GG Series  
Specifications  
• Power entry module with enhanced EMI filter  
Maximum leakage current each Line to Ground:  
HG Models  
2 A  
GG Models  
• Single or dual fusing  
@ 120 VAC 60 Hz:  
@250 VAC 50 Hz:  
.25 mA  
.42 mA  
• Two element circuit provides basic attenuation  
5 A  
• Available with an internal ground-circuit inductor  
(C versions) to isolate equipment chassis from  
power line ground at radio frequencies  
Hipot rating (one minute):  
Line to Ground:  
2250 VDC  
1450 VDC  
Line to Line:  
• Multiple termination and mounting styles  
Rated Voltage (max.):  
Operating Frequency:  
Rated Current:  
250 VAC  
50/60 Hz  
1 to 10A  
HG Series  
• Medical version of our GG Series  
• Mechanically identical to GG Series  
• Available only with dual fusing  
Required Fuse(s):  
5 x 20mm  
(not included)  
Ordering Information  
3 E GG 1 C -2  
Available Part Numbers  
Metric Fuse Holders  
1 – Single  
2 – Double  
Filtered modules  
1EGG1-1  
1EGG1-2  
1EGG8-1  
1EGG8-2  
1EGS1-1  
3EGG1-1  
3EGG1-2  
3EGG8-1  
3EGG8-2  
3EGS1-1  
3EGS1-2  
6EGG1-1  
6EGG1-2  
6EGG8-1  
6EGG8-2 10EGG8-2  
6EGS1-1  
6EGS1-2  
10EGG1-1  
10EGG1-2  
10EGG8-1  
Ground Circuit Inductor  
Omit if none  
10EGS1-1  
10EGS1-2  
1EGS1-2  
Output Styles  
Filtered modules with ground circuit inductor  
1EGG1C-1 3EGG1C-1 6EGG1C-1  
1EGG1C-2 3EGG1C-2 6EGG1C-2  
1EGG8C-1 3EGG8C-1 6EGG8C-1  
1EGG8C-2 3EGG8C-2 6EGG8C-2  
1 – .250 [6.3] spade terminals  
8 – Wire leads  
GG or HG Series (Flange mount)  
GGS or HGS Series (Snap-in mount)  
Medical filter modules  
Leakage current designation  
E – Low leakage (<0.5 mA)  
1EHG1-2  
1EHG8-2  
3EHG1-2  
3EHG8-2  
6EHG1-2  
6EHG8-2 10EHG8-2  
10EHG1-2  
1EHGS1-2 3EHGS1-2 6EHGS1-2 10EHGS1-2  
Current Rating  
1, 3, 6 or 10A  
166  
Dimensions are in inches and millimeters unless otherwise specified. Values in italics  
are metric equivalents. Dimensions are shown for reference purposes only.  
Specifications subject to change.  
For email, phone or live chat, please go to  
te.com/help  
corcom.com  
Catalog: 1654001  
Issue Date: 06.2011  
Corcom Product Guide  
Smallest Power Entry Module with Metric Fuse Holders (continued)  
GG & HG Series  
Electrical Schematic  
GG8 & HG8  
LINE  
LOAD  
1
Blue  
2
3
3
Green/Yellow  
B
D
E
Brown  
  
  
A
  
  
C
  
Accessories  
GA400  
: NEMA 5-15P to IEC 60320-1 C-13 line cord  
  
  
  
  
   
   
   
3
Case Dimensions  
A
Part No.  
  
B
  
C
  
D
E
  
  
  
  
GG1 & HG1  
  
  
  
  
  
  
  
  
  
  
  
  
  
Case Styles  
  
GG1, GG1C & HG1  
GG1C  
  
  
  
  
  
  
GS1, HGS1  
  
  
GG8, HG8  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
C
D
E
  
A
B
  
  
Recommended Panel Cutouts  
  
  
  
GG / HG  
GS / HGS  
   
   
  
  
  
1.14  
1.24  
29.0  
31.5  
GS1 & HGS1  
1.30  
33.0  
1.29  
32.8  
D
C
1.417  
36.0  
E
A
B
Front or Back Mount  
Front Mount Only  
  
   
  
  
  
  
   
  
  
  
167  
Dimensions are in inches and millimeters unless otherwise specified. Values in italics  
are metric equivalents. Dimensions are shown for reference purposes only.  
Specifications subject to change.  
For email, phone or live chat, please go to  
te.com/help  
corcom.com  
Catalog: 1654001  
Issue Date: 06.2011  
Corcom Product Guide  
Smallest Power Entry Module with Metric Fuse Holders (continued)  
GG & HG Series  
Performance Data  
Typical Insertion Loss  
GG & GS Models  
Measured in closed 50 Ohm system  
1A  
3A  
6A  
10A  
db  
db  
db  
db  
100  
100  
100  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
0
0
0
0.1  
1
10  
30  
0.1  
1
10  
30  
0.1  
1
10  
30  
0.01  
0.1  
1
10  
30  
Frequency in MHz  
Frequency in MHz  
Frequency in MHz  
Frequency in MHz  
3A GG1C  
6A GG1C  
db  
db  
100  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
Common Mode / Asymmetrical (L-G)  
Differential Mode / Symmetrical (L-L)  
0
0
0.1  
1
10  
30  
0.1  
1
10  
30  
Frequency in MHz  
Frequency in MHz  
HG Models  
1A  
3A  
6A  
10A  
db  
db  
db  
db  
100  
100  
100  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
0
0
0
0.1  
1
10  
30  
0.1  
1
10  
30  
0.1  
1
10  
30  
0.1  
1
10  
30  
Frequency in MHz  
Frequency in MHz  
Frequency in MHz  
Frequency in MHz  
Measured in closed 50 Ohm system  
Minimum Insertion Loss  
Common Mode / Asymmetrical (Line to Ground)  
Differential Mode / Symmetrical (Line to Line)  
   
  
    
      
   
  
    
    
   
   
   
   
  
          
  
       
       
       
      
  
         
  
  
       
    
  
  
  
   
   
  
  
          
  
  
       
       
       
         
  
        
  
  
  
  
   
    
168  
Dimensions are in inches and millimeters unless otherwise specified. Values in italics  
are metric equivalents. Dimensions are shown for reference purposes only.  
Specifications subject to change.  
For email, phone or live chat, please go to  
te.com/help  
corcom.com  

相关型号:

3EGG8-1

Smallest Filtered Power Entry Modules with Metric Fuseholders
TE

3EGG8-2

Smallest Filtered Power Entry Modules with Metric Fuseholders
TE

3EGG8C-1

Smallest Power Entry Module with Metric Fuse Holders
TE

3EGG8C-2

Smallest Power Entry Module with Metric Fuse Holders
TE

3EGS1-1

Smallest Filtered Power Entry Modules with Metric Fuseholders
TE

3EGS1-2

Smallest Filtered Power Entry Modules with Metric Fuseholders
TE

3EH1

Power Inlet Line Filter for Medical Equipment
TE

3EH3

Power Inlet Line Filter for Medical Equipment
TE

3EHG1-2

Smallest Filtered Power Entry Modules with Metric Fuseholders
TE

3EHG1-2

Smallest Power Entry Module with Metric Fuse Holders
MACOM

3EHG8-2

Smallest Power Entry Module with Metric Fuse Holders
TE

3EHGS1-2

Smallest Filtered Power Entry Modules with Metric Fuseholders
TE