PSL0XSS60 [TE]

The CHAMELEON Adaptable Module for General, High Performance or Medical Applications; 变色龙适应模块通用,高性能和医疗应用
PSL0XSS60
型号: PSL0XSS60
厂家: TE CONNECTIVITY    TE CONNECTIVITY
描述:

The CHAMELEON Adaptable Module for General, High Performance or Medical Applications
变色龙适应模块通用,高性能和医疗应用

医疗
文件: 总8页 (文件大小:218K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
CORCOM Product Guide  
The CHAMELEON Adaptable Module for General, High Performance or  
Medical Applications  
P Series  
UL Recognized  
CSA Certified  
VDE Approved  
PS Unfiltered  
PS000SS30  
PS Filtered  
H m o d e ls provide susceptibility protection without leak-  
age current associated with line-to-ground capacitors and  
are designed to allow equipment to meet UL 544 for patient  
care and non-patient care equipment.  
P Series  
The P series power entry module offers fuller flexibility of  
design in a more compact package.  
As the first 10 amp module to provide all five power entry  
functions in one compact design, the CHAMELEON  
module readily adapts to its environment and the needs of  
international markets.  
Also available is an interconnection block, B m o d e ls .  
The block connects the voltage selection terminals of an  
unfiltered CHAMELEON module with a switch and an IEC  
connector to reduce external wiring.  
Snap-in or flange mounting  
L Mo d e ls – High performance medical filter versions that  
are designed to help bring most digital equipment (includ-  
ing switching power supplies) into compliance with  
EN55022, Level B (as well as FCC part 15J, Class B)  
conducted emissions limits while additionally allowing  
equipment to meet UL544, UL2601and EN60601 for patient  
care equipment and non-patient care equipment. They are  
available with current ratings of 6 and 10 amps. High  
performance versions are available with horizontal mount-  
ing ears, single voltage, complete can shield with options  
for switch, fuses and current ratings only. Extenders are  
not available.  
IEC power line connector  
Both North American and European fusing capabilities  
Two voltage selections  
Optional DPST on/off switch  
Filtering options for general purpose, medical and  
high-performance applications.  
The CHAMELEON modules compact design and modular  
construction will allow you to select the power entry  
features you require — without altering the panel cutout.  
And the Chameleon module, with adapters, will fit any  
standard panel cutout.  
Z Mo d e ls – High performance filter versions are designed  
to help bring most digital equipment (including switching  
power supplies) into compliance with EN55022, Level B  
(as well as FCC Part 15J, Class B) conducted emissions  
limits. They are available with current ratings of 6 and 10  
amps. High performance versions are available with  
horizontal mounting ears, no extenders, single voltage,  
complete can shield with options for switch, fuses and  
current ratings only.  
The CHAMELEON module has four filter options.  
S m o d e ls offer protection for general purpose applica-  
tions where line-to-ground and line-to-line noise must be  
controlled. The filters are designed to meet low leakage  
requirements of VDE portable equipment. They are  
available in current ratings of 3, 6 and 10 amps.  
PE Filter with "A" Shield  
132  
Catalog 1654001  
Revised 05-07  
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in italics  
are metric equivalents.  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA Cust. Svc.: 1-800-468-2023  
CORCOM Prods: 1-847-680-7400  
www.corcom.com  
www.tycoelectronics.com  
Germany:  
49-89-6089-0  
CORCOM Product Guide  
The CHAMELEON Adaptable Module for General, High Performance or  
Medical Applications (Continued)  
P Series  
P Series Part Number Schematic  
Part numbers are constructed by selecting the alphanumeric character which represents the desired feature.  
Mounting Extender Switch  
Voltage  
Select  
Fuse  
Options  
Filter  
Type  
Filter  
Current Options*  
Shield  
Style  
Options* Options  
**  
J 0 X S  
0
S
6
P
S
Mounting Style  
E = Mounting ears  
(Horizontal)  
S = Snap-in  
M = Mounting ears  
(Vertical)  
Switch Option  
0 = Blank  
S = Double pole  
single throw  
(DPST)  
Fuse Options  
D = Dual fuse  
S = Single fuse  
Filter Current  
0 = No filter  
3 = 3 amps  
6 = 6 amps  
X = 10 amps  
Extender  
Option  
0 = None  
C = FN260  
J = J Series  
L = L Series  
Input Voltage Select  
Filter Type  
0 = No filter  
Shield Options  
0 = No shield  
A = Filter shield  
B = Complete  
Shield  
0 = Single voltage  
S = Dual voltage  
B = Interconnection  
block  
H = Medical Filter  
L = High Performance  
Medical  
**  
select (SMPS)  
X = Dual voltage  
**  
select (series/parallel)  
C = Complete can  
(for L & Z models)  
S = General purpose  
Z = High Performance  
***  
Notes:  
An additional extender which allows the P series to adapt to Corcom's L  
series product cutout as well as the panel cutout of Schaffner and Delta  
parts is also available.  
Extenders cannot be added to units with B shields  
When using the interconnection block, the last 3 digits of the part number  
are BX (0, A, or B)  
Extender for  
J-Series or others  
Fuse holder  
For alternative switch orientation options, please contact technical sup  
port or your Corcom sales representative  
** Dual voltage options only available with filter types O, H or S  
••• High performance versions are available with horizontal mounting ears  
(PE style), no extenders, single voltage, complete can shield with options  
for switch, fuses, filter type (L or Z) and 6 or 10 amp current ratings only.  
Optional switch  
The part number PSJ0XSS60 would represent the equivalent of the Corcom  
J Series 6J4:.  
P Series (P )  
with a snap-in mount (S )  
Optional filter  
with the J extender to fit the 6J4 cutout(J), and includes no switch (0 )  
dual voltage select (X)  
single fusing (S ),  
general purpose filter (S )  
for 6 amps (6 )  
with no shield (0 ).  
Additional extender which allows the P series to adapt to CORCOM's L  
series product cutout, as well as the panel cutout of Schaffner and Delta  
parts is available.  
* Extenders cannot be added to units with B shields.  
133  
Catalog 1654001  
Revised 05-07  
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in italics  
are metric equivalents.  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA Cust. Svc.: 1-800-468-2023  
CORCOM Prods: 1-847-680-7400  
www.corcom.com  
www.tycoelectronics.com  
Germany:  
49-89-6089-0  
CORCOM Product Guide  
The CHAMELEON Adaptable Module for General, High Performance or  
Medical Applications (Continued)  
P Series  
Voltage Selection  
Input Voltage Selection Schemes  
The P series of power entry modules provides a dual volt-  
age selector which is integrated with the fuseholder. To  
simplify the wiring in each individual application, Tyco  
Electronics provides dedicated voltage selectors for differ-  
ent voltage selection schemes. The two most popular  
schemes are the parallel and serial for dual primary trans-  
formers and the DPST switch” for switching mode power  
supplies (jumper types.) P series products with an S” as  
the fifth digit are specifically designed for jumper” type  
applications associated with switching mode power sup-  
plies. P series products with an X” as the fifth digit are  
specifically designed for dual primary transformer applica-  
tions. The voltage selector installed will allow proper wiring  
from these applications. No matter what voltage selection  
scheme is used, wiring is always made to the same four  
terminals.  
X - Dual Primary Transformer Type  
115V  
230V  
Power on/off  
G
A
B
C
Hot  
Ground  
Neutral  
115V  
115V  
Note 2  
Note 2  
Note 1  
Note 1  
H
D
Transformer  
primary  
Provision for  
single fusing  
S - Jumper Type  
115V  
230V  
Power on/off  
Power  
input  
Hot  
Ground  
Neutral  
G
A
B
C
Note 1  
Note 1  
Note 1  
Note 1  
Sel.  
Jumpers  
H
D
SMPS  
Provision for  
single fusing  
Note 1: Jumpers are required if a filter or interconnection module is not  
used.  
Note 2: Location of optional filter. Jumpers are required if a filter or  
interconnection block is not used.  
Shield  
A new feature available on the P series is an RF shield. The  
metal shield, available on filtered models, provides shield-  
ing from radiated emissions and provides an additional RF  
ground for the filter to the case. The shield is available in  
two versions, a shield of the filter components (designated  
by A as the ninth digit) and a complete shield (designated  
by B as the ninth digit). The A shield covers the filter por-  
tion of the module and increases performance of the filter  
by protecting the components from magnetic coupling.  
This shield improves RF ground connection to the case  
while still allowing the use of the P Series extender. The B  
shield covers the entire power entry module with metal,  
protecting the equipment from all radiated noise. Used  
with the filter, the shield provides the most secure protec-  
tion from RFI noise problems. The B shield cannot be used  
with any extender.  
A Shield  
B Shield  
134  
Catalog 1654001  
Revised 05-07  
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in italics  
are metric equivalents.  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA Cust. Svc.: 1-800-468-2023  
CORCOM Prods: 1-847-680-7400  
www.corcom.com  
www.tycoelectronics.com  
Germany:  
49-89-6089-0  
CORCOM Product Guide  
The CHAMELEON Adaptable Module for General, High Performance or  
Medical Applications (Continued)  
P Series  
Fuseholder  
Another feature of the P series power entry module is a ver-  
satile fusing arrangement. Its fuseholder can hold two 1/4”  
x 1-1/4” or 5 x 20mm fuses. It can also be converted to  
accept one fuse with a conversion clip that bridges one of  
the two fuse chambers. The conversion clip is installed on  
the P Series power entry modules set for single fusing  
(those with part numbers with an S” as the sixth digit).  
Units with a “D” as the sixth digit do not include a conver-  
sion clip.  
Fuseholder shown with 5x20mm fuse  
Conversion clip included for use in single  
fuse applications.  
Interconnection Block  
Also available is an interconnection block (B models). The  
block connects the voltage selection terminals of an unfil-  
tered CHAMELEON module with a switch and an IEC con-  
nector to reduce external wiring. Installation of the unfil-  
tered versions of the P series involves wiring of the IEC  
socket to the switch and the switch to the fuseholder. Labor  
can be eliminated by ordering the product with an intercon-  
nection block. This feature, designated by a BX in the sev-  
enth and eighth digits, pre wires the module for easier  
installation. The wiring is protected with the plastic case to  
better prevent access to the terminals and connections.  
The dimensions of this alternative are the same as the  
filtered versions.  
Interconnection Block installed in place of filer.  
Accessories  
A full range of accessories are available for the P Series.  
To simplify customer installation wiring can be simplified by  
ordering a PA100 connector assembly which is pre-wired  
with 6" of wire lead.  
See page 143 for a complete list of all accessories  
available for this series.  
PA100 Assembly  
135  
Catalog 1654001  
Revised 05-07  
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in italics  
are metric equivalents.  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA Cust. Svc.: 1-800-468-2023  
CORCOM Prods: 1-847-680-7400  
www.corcom.com  
www.tycoelectronics.com  
Germany:  
49-89-6089-0  
CORCOM Product Guide  
The CHAMELEON Adaptable Module for General, High Performance or  
Medical Applications (Continued)  
P Series  
Electrical Schematics  
Minimum insertion loss in dB:  
H Model  
Line-to-ground in 50 ohm circuit  
Current  
Rating  
H Models  
03A  
06A  
10A  
Frequency-MHz  
.03 .1 .15 .5  
1
3
5
10  
30  
7
-
17 21 27 30 29 26  
23  
16  
10  
15  
13  
10  
8
5
11 15 17 19 18  
10 12 11 11  
S Model  
3
8
S Models  
03A  
06A  
7
-
-
17 21 27 33 40 44  
50  
44  
35  
32  
30  
27  
8
3
12 17 23 32 36  
10A  
5
10 13 23 27  
L Model  
LINE  
LOAD  
Current  
Rating  
Z Models  
06A  
Frequency-MHz  
.01 .05 .1 .15 .5  
1
5
10  
30  
8
5
21 27 30 37 43 49  
17 22 24 27 32 52  
52  
47  
42  
40  
Z Model  
10A  
LINE  
L Models  
06A  
LOAD  
8
5
21 27 29 34 35 25  
17 22 23 24 25 21  
21  
18  
16  
14  
10A  
Line-to-line in 50 ohm circuit  
Specifications  
Current  
Frequency-MHz  
.10 .15 .5  
Rating  
H Models  
03A  
06A  
10A  
1
3
5
10  
30  
Maximum leakage current, each line-to-ground: †  
H & L Models  
2 µA  
S & Z Models  
.25 mA  
2
2
2
4
4
4
12 18 31 40  
12 16 26 35 40  
12 16 26 33  
48  
41  
35  
32  
@ 120 VAC 60 Hz:  
@ 250 VAC 50 Hz:  
Applies to Filtered models only  
Hipot rating (one minute):  
line-to-ground  
line-to-line  
Operating frequency:  
Rated voltage:  
5 µA  
.50 mA  
40  
S Models  
03A  
06A  
2
2
2
4
4
4
12 15 30 48  
12 15 22 42  
12 15 22 42  
50  
55  
55  
45  
45  
45  
1500 VAC  
1450 VAC  
50/60 Hz  
250 VAC  
10A  
Operating voltages:  
Selectable or Fixed  
Rated current:  
Current  
Rating  
Z Models  
06A  
Frequency-MHz  
115/230 VAC  
Unfiltered – 10A  
Filtered – 3, 6 or 10A  
.01 .05 .1 .15 .5  
1
5
10  
30  
10 15 34 44 75 75 75  
10 20 20 35 67 75 75  
70  
70  
60  
60  
Switch:  
Double-insulated, rated  
10A  
for 10,000 operations at full load at  
51 Amp inrush current.  
L Models  
06A  
10A  
10 15 34 44 75 75 75  
10 20 20 35 67 75 75  
70  
70  
60  
60  
Fuseholder:  
Accepts one or two fuses  
1/4 x 1-1/4 or 5 x 20 mm  
Conversion clip provided on fuseholder  
for single fuse models.  
Terminals:  
Standard versions:  
High performance versions:  
.187 x 0.032  
[4.8 x .81] terminal tabs  
.250 x 0.032  
[6.4 x .81] terminal tabs  
Recommended for use with mating connector - no solder  
136  
Catalog 1654001  
Revised 05-07  
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in italics  
are metric equivalents.  
Dimensions are shown for  
USA Cust. Svc.: 1-800-468-2023  
CORCOM Prods: 1-847-680-7400  
www.corcom.com  
www.tycoelectronics.com  
reference purposes only.  
Specifications subject  
to change.  
Germany:  
49-89-6089-0  
CORCOM Product Guide  
The CHAMELEON Adaptable Module for General, High Performance or  
Medical Applications (Continued)  
P Series  
Case Styles  
PS/PSL  
.06  
1.52  
R Max  
C
E
C
(Note 1)  
.020  
.508  
R Min  
.225  
5.72  
.225  
5.72  
B1  
D
A
B2  
Panel Cutout  
UnÞltered  
Filtered  
Note1: For snap-in applications, the D sides of the cutout must have a .02 [.508] radius on the installation side.  
Snap-in models allow front mounting only. Not recommended for plastic panels.  
.06  
1.52  
R Max  
PE  
E
C
C
.020  
.508  
R Min  
D
F
.225  
5.72  
.225  
5.72  
D
F
Max.  
Max.  
B2  
B1  
Panel Cutout  
UnÞltered  
Filtered  
A
PM  
A
D
D
F
F
E
C
.06  
1.52  
R Max  
.225  
.225  
5.72  
5.72  
Max.  
B2  
Max.  
B1  
UnÞltered  
Filtered  
Panel Cutout  
Typical dimensions:  
Terminals: .187 x 0.032 [4.8 x .81] terminal tabs  
Slot (Ground Terminal): .06 x .115 [1.52 x 2.92] ± .004 [.10]  
Holes: .055 [1.5] Dia. ± .004 [.10]  
Mounting Holes (PE, PM only) : .135 [3.43] Dia. (2) countersunk  
137  
Catalog 1654001  
Revised 05-07  
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in italics  
are metric equivalents.  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA Cust. Svc.: 1-800-468-2023  
CORCOM Prods: 1-847-680-7400  
www.corcom.com  
www.tycoelectronics.com  
Germany:  
49-89-6089-0  
CORCOM Product Guide  
The CHAMELEON Adaptable Module for General, High Performance or  
Medical Applications (Continued)  
P Series  
Case Styles (continued)  
PSC/PSJ  
.06  
1.52  
R Max  
C
E
(Note 1)  
.020  
R Min  
.508  
D
.225  
5.72  
.225  
5.72  
Max.  
B2  
B1  
UnÞltered  
A
Filtered  
Panel Cutout  
Note 1: For snap-in applications, the D sides of the cutout must have a .02 [.508] radius on the installation side. Snap-in models, allow front mounting only.  
Typical dimensions:  
Terminals: .187 x 0.032 [4.8 x .81] terminal tabs  
Holes: .055 [1.5] Dia. ± .004 [.10]  
Slot (Ground Terminal): .06 x .115 [1.52 x 2.92] ± .004 [.10]  
Mounting Holes (PE, PM only) : .135 [3.43] Dia. (2) countersunk  
PE High Performance  
3.93 Max.  
C
2.39 Max.  
2.17 Max.  
F
A
.225  
5.72  
B2  
D
Rear View  
Note 1: Use cutout for PE Style.  
Typical dimensions:  
Terminals: .250 x 0.032 [6.4 x .81] terminal tabs  
Slot (Ground Terminal): .07 x .16 [1.8 x 4.1]  
Holes: .07 [1.8] Dia. (2)  
Mounting Holes: .135 [3.43] Dia. (2) countersunk  
138  
Catalog 1654001  
Revised 05-07  
Dimensions are in inches and  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA Cust. Svc.: 1-800-468-2023  
CORCOM Prods: 1-847-680-7400  
Germany: 49-89-6089-0  
www.corcom.com  
www.tycoelectronics.com  
millimeters unless otherwise  
specified. Values in italics  
are metric equivalents.  
CORCOM Product Guide  
The CHAMELEON Adaptable Module for General, High Performance or  
Medical Applications (Continued)  
P Series  
Shielding  
Case Dimensions  
A
B1  
B2  
C
D
E
F
Part No.  
(max) (max) (max) (max) +.008/-.000  
+.008/-.000  
+.20/-.00  
+.20/-.00  
1.24 1.93 2.13 2.31 1.062.201*  
31.49 49.02 54.1 58.67 26.93 55.91  
1.24 1.93 2.13 2.31 1.12 2.201*  
31.49 49.02 54.1 58.67 28.45 55.91  
PS  
PSL  
PE  
1.98 1.93 2.13 2.31 1.122 2.201* 1.575  
0.225  
0.225  
2.19 Max  
2.19 Max  
50.29 49.02 54.1 58.67 28.5 55.91 40.0  
.508  
.508  
Max.  
Max.  
1.24 1.93 2.13 2.9  
1.06 2.13 2.496  
PM  
A Shield  
B Shield  
31.49 49.02 54.1 73.66 26.93 54.1 63.4  
Shields can be used only with filtered models.  
Shields add approximately 0.06" to depth.  
B shield may not be used with J or C extender.  
1.24 1.93 2.13 2.51 1.06 2.52  
PSC  
PSJ  
31.49 49.02 54.1 63.75 26.93 64.01  
+
1.24 1.93 2.13 2.72 1.06  
2.6  
31.49 49.02 54.1 69.09 26.93 66.0  
Rear View  
PE  
1.98  
4.42 2.31 1.12 2.201 1.575  
High  
50.29  
112.27 58.67 28.5 55.91 40.0  
B
C
B
C
D
A
D
A
Performance  
*
Panel cutout for thickness of .031 - .079 [0.8 - 2.0]. For panel thickness  
at .083 - .114 [2.1 - 2.9] use 2.213 [56.21].  
+
Panel cutout for thickness of 0.06 - 0.09 [0.76 - 2.29].  
For shielded models use D=1.12 +.008/-.000.  
L
N
GND  
GND  
Filtered  
UnÞltered  
139  
Catalog 1654001  
Revised 05-07  
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in italics  
are metric equivalents.  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA Cust. Svc.: 1-800-468-2023  
CORCOM Prods: 1-847-680-7400  
www.corcom.com  
www.tycoelectronics.com  
Germany:  
49-89-6089-0  

相关型号:

PSL12

Monostable or bistable relays Single and double Coil magnet latching Type available
DBLECTRO

PSL12

SILICON EPITAXIAL PLANER TYPE
PACELEADER

PSL12-M

SILICON EPITAXIAL PLANER TYPE
PACELEADER

PSL12-MH

SILICON EPITAXIAL PLANER TYPE
PACELEADER

PSL12-N

SILICON EPITAXIAL PLANER TYPE
PACELEADER

PSL126-7LIPCD1A

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL

PSL126-7LIPCDA

DC-DC Regulated Power Supply Module, 1 Output, 72W, METAL, CASE L04, MODULE
BEL

PSL126-7LIPD1A

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL

PSL126-7LIPDA

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL

PSL126-7LIRPCDA

DC-DC Regulated Power Supply Module, 1 Output
BEL

PSL126-7LRCDA

DC-DC Regulated Power Supply Module, 1 Output, 72W, METAL, CASE L04, MODULE
BEL

PSL126-7LRD1A

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL