DS92UT16
DS92UT16TUF UTOPIA-LVDS Bridge for 1.6 Gbps Bi-directional Data Transfers
Literature Number: SNOS992D
OBSOLETE
July 19, 2011
DS92UT16TUF
UTOPIA-LVDS Bridge for 1.6 Gbps Bi-directional Data
Transfers
Two independent LVDS receiver serial ports for
optional 1:1 protection
Main and redundant LVDS transmit ports
—
1.0 General Description
The DS92UT16 is a flexible UTOPIA to LVDS Bridge device.
The LVDS Bridge transparently transports the UTOPIA bus
over a high speed LVDS serial link. The device includes many
reliability features such as an optional 1:1 protection and built
in bit error rate checking.
—
—
Loop timing capability enables LVDS recovered clock
to internally drive LVDS transmit clock
Internal buffers allow maximum LVDS serial bit rate
independent of UTOPIA clock rate
—
The parallel interface is user programmable for maximum
flexibility. The user can choose between UTOPIA Level Level
2 ATM layer (master) of PHY layer (slave). The UTOPIA-
LVDS Bridge supports a special MPHY (multi-PHY layer)
operation mode. The MPHY operation supports up to 248
standard UTOPIA Level 2 PHY ports without adding external
circuitry.
Programmable UTPIA interface
■
UTOPIA Lev2 up to 52 MHz
ATM layer Hayer nterface
—
—
—
ATM lar intercsupport up to 248 standard
Level HY ports no additional external circuitry.
Coas 31 MPHY’s, each with up to 8 sub-ports
The serial interface uses LVDS Serializer and Deserializer
technology. The 16:1 bit serialization allows conveying the
full-duplex parallel bus over two differential transmission
pairs. This enables low cost backplanes and cables. Cable
transmission length can be as long 16 meters.
Supports ded cell size up to 64 bytes
upports 16- o8-bit data buses with parity
—
—
bedd bidirectional, non-blocking flow control over
nk foer MPHY back pressure
No ememories required
■
■
■
The serial link carries Flow control information (back pres-
sure) in both directions. The Bridge device applies back pres
sure on a per queue basis over the 31 internal FIFO queues.
In addition, the serial link includes an OAM (Operations and
Maintenance) channel that does not detract from link
mance.
Embeddd OAM channel over serial link
Rote Alarm/Status Indications
nk Trace Label
—
—
Embedded Control Channel with flow control for
software communication
There are many applications where the UTOP
Bridge simplifies designs. Box-to-box connections c
DS29UT16 devices across cables. Access miplexor appi
cations can use the devices across a PCbacke for
point-to-point and lightly loaded multidrop ctio
BIP16 based error performance monitoring
—
—
In protected systems, the standby link OAM channel is
available for embedded communications and
performance/alarm monitoring
Multiple loop-back options
■
■
Standard microprocessor interface (Intel and Motorola
compatible)
IEEE 1149.1 JTAG port
2.0 Features
832 Mbps LVDS 16-bit serializeer interface
■
■
■
■
■
Suitable for cable, printed circuid backplane
transmission paths
—
—
—
—
Temperature range: −40°C to +85°C
CMOS technology for low power
10m cable at max Le and greater than
16m at min LVDS d
LVDS transceiver section uses 3.3V power supply. Digital
UTOPIA section uses 2.5V power supply. All I/O are 3.3V
tolerant.
Embedded clock wita lock capability for
clock recovery
196 LBGA package, 15x15x1.37 mm, 1.0 mm ball pitch
■
PRBS (x31 + x28 + 1) based LVDS link BER test facility
3.0 Ordering Information
Order Number
Package Information
196 LBGA package, 15x15x1.37 mm, 1.0 mm ball pitch
Package Number
DS92UT16TUF
NUJB0196
© 2011 National Semiconductor Corporation
200316
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
4.0 Block Diagram
20031601
RE 1. DS92UT16 Block Diagram
www.national.com
2
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
5.0 Application Overview
20031602
FIGURE 2. Application Example
The UTOPIA interface [1. See Section 21.0 References] is an
established standard for connecting Physical Layer devices
to ATM Layer devices. However, when the ATM Layer device
and the Physical Layer device(s) are on separate cards within
a piece of equipment, or even on separate equipment, then
the parallel nature of this standard becomes a limiting factor.
See Figure 2.
n emining the trade-offs that determine the DS92UT16
mam cadrive capability, it is important to understand
that thdata rate on the cable is 18 times (16 bits plus
2 embeddd clock bits) the LVDS_TxClk rate. For example,
a 35 Mz LVDS_TxClk will produce a 630 Mbps data rate,
d 2 MHz clock will produce a 936 Mbps data rate. When
utwinaxial grade differential cable, the cable length can
be as long as 16m for the 35 MHz clock and approximately
10m for the 52 MHz clock.
The solution is to use the DS92UT16, which is a trans
bridge that extends the UTOPIA bus over a serial LV
terface, and is suitable for backplanes and cables. Fu
rectional flow control is incorporated, allowing b-press
to be applied to the source of the ATM cells. Th1 PHY ports
available with standard UTOPIA Level 2 may eo
248 ports without additional external circuitry. The DS92U6
achieves this by providing as many as 8 and CLAsig-
nals in both receive and transmit dirn acting as
the ATM Layer device. This allows aHYs that
are configured as up to 31 ports that emany as
8 sub-ports.
6.0 Functional Description
6.1 UTOPIA INTERFACE
The DS92UT16 has an industry standard UTOPIA interface
[1.] supporting Level 2 and Extended Level 2 operation. De-
pending on its position in the bridge link, it may operate as
either the ATM layer or the physical layer in the UTOPIA pro-
tocol.
In Level 2 mode, this interface can be either a 16-bit or an 8-
bit wide data path, with both octet and cell level handshaking
and operating at a frequency as high as 52 MHz, facilitating
622 Mbps (STM4/OC12) line rates.
To aid equipment managmaintenance, the
DS92UT16 passes an embens, Administration
and Maintenance' (OAM) che serial link. In ad-
dition, the device provides a nopback options that
are both traffic affecting (line loopbacks) and non-traffic af-
fecting (cell loopbacks), which simplify testing and diagnostic
activities.
In UTOPIA Level 2 mode, the device supports Multi-PHY
(MPHY) operation, whereby up to 31 PHY ports may be con-
nected to an ATM device. The presence of cells and avail-
ability of buffer space is indicated using the CLAV signals.
The DS92UT16 has a modified Bus LVDS serial output for
driving cables in point-to-point applications. The cable length
depends on the quality of the cable and the data rate. In-
creasing the cable quality, or lowering the LVDS data rate,
increases the maximum possible cable length the device will
drive.
UTOPIA Level 2 defines 1 ENB and 1 CLAV signal in each
direction. The DS92UT16 has extended this to 8 ENB and 8
CLAV signals, which enables up to 248 PHY ports to be con-
nected to an ATM device without additional external circuitry
as shown in Figure 3.
3
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
20031603
Note: The full connections for a single sub-port are shown in Figure 4.
FIGURE 3. Extended UTOPIA Level 2 PHY Ports
20031627
FIGURE 4. Detailed Connection of One Sub-Port for Extended UTOPIA Level 2
www.national.com
4
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
For the purposes of queueing, the 248 PHY ports are config-
ured as sub-ports of the standard 31 ports so each port/queue
has 8 sub-ports as discussed in Section 6.2.2 Up-Bridge Mul-
ti-Port Traffic Buffer. Each MPHY address corresponds to a
port.
•
•
Standard UTOPIA Level 2 with 1 CLAV signal.
One CLAV polling 31 PHY ports.
—
DS92UT16 Extended UTOPIA Level 2 with up to 8 CLAV
signals.
Each CLAV can poll 31 PHY ports giving a total of 248
PHY ports.
—
The 5 bit MPHY can address up to 31 PHY ports. At least 3
additional bits are required to give the total of 8 bits necessary
for addressing 248 PHY ports. These additional address bits
can be provided by the user in any of the User Prepend, Cell
Header or UDF1/2 bytes of the cell as shown in Figure 6. The
DS92UT16 is configured to extract/insert the extra address
bits from/to any of these bytes.
Multiple UTOPIA-LVDS bridge devices can be used in parallel
to share up to 31 PHY ports among PHYs that are on separate
line cards Figure 5. Each of these ports may have up to 8 sub-
ports. There are constraints on the number of port addresses
used per bridge in such a configuration. See Section 9.2
MULTIPLE BRIDGE MTB CONFIGURATION
PHY polling may be carried out as follows:
20031604
Note: Default MTB queue thresholds must be changed se this nfiguration. See Section 9.2 MULTIPLE BRIDGE MTB CONFIGURATION
FIGURE 5. Mi-Bridge System Example
Parity generation and checking is avodes.
6.2.2 Up-Bridge Multi-Port Traffic Buffer
To support systems where routing tagdding are
added to the ATM cells at a previous devicUTOPIA in-
terface on DS92UT16 may bmed to handle non-
standard ATM cells of lengto 64 bytes. See
Figure 6. In all cases, the SOC) signal must
correspond to the first byte or extended cell.
In the up-bridge direction, a 160 cell linked list buffer is shared
across up to 31 port queues. This is called the Multi-port Traf-
fic Buffer. Although each MPHY may be connected to 8 sub-
ports/PHY's, the MTB has a single queue per MPHY port, as
it only uses the 5-bit MPHY address and does not access the
sub-port address bits.
Back-to-back cell transfer is supported in all modes.
Each port has a programmable upper fill threshold. In the up-
bridge direction, queue overflow is avoided through the
means of a per queue flow control protocol embedded in the
LVDS link as described in Section 6.3.5 Flow Control. Should
any queue reach this upper threshold, back-pressure is ap-
plied via the flow control mechanism over the serial link to the
down-bridge (transmitting) device which uses the normal
UTOPIA flow control handshaking to prevent any more cells
being transferred and thus prevent overflow.
When configured as an ATM layer device, receive polling and
transmit polling of those Ports with queued cells is Round-
Robin. The DS92UT16 will only poll those PHY ports config-
ured as active.
6.2 TRAFFIC BUFFERS
6.2.1 Down-Bridge FIFO
In the down-bridge direction, a simple 3 cell FIFO (with 30 cell
overhead) is used to rate adapt the data from the UTOPIA
clock domain to the LVDS clock domain for transmission. Per
port queuing and back pressure/flow control is handled by the
corresponding up-bridge Multi-port Traffic Buffer in the far end
DS92UT16 device as described in Section 6.2.2 Up-Bridge
Multi-Port Traffic Buffer and Section 6.3.5 Flow Control.
The individual queue per port architecture ensures that the
flow control is non-blocking across the 31 ports. However, the
8 sub-ports within each port can be blocking.
Furthermore, as is the nature of link-list buffers, each queue
may be over-assigned memory space, working on the as-
sumption that not every queue will back up simultaneously.
To accommodate the rare occasions where the buffer as a
whole approaches full but individual queues are below their
5
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
full threshold, the device also compares the overall buffer fill
against a threshold. The flow control mechanism provides a
global ‘halt' command to ensure that no cells will be lost if the
overall buffer should approach the overflow condition.
This is illustrated in Figure 6.
The PDU fields are configured as shown in Table 1. The total
PDU cell length must be in the range of 52 to 64 bytes. In
addition, variable length fields must be programmed to an
even number of bytes because the DS92UT16 operates with
an internal 16 bit data path. The total number of bytes defined
for User Prepend plus UDF1/2 and User Append must not
exceed 12 bytes to maintain the maximum PDU cell length of
64 bytes.
6.3 TRANSMISSION CONVERGENCE SUB-LAYER (TCS)
In the down-bridge direction, the Transmission Convergence
Sub-layer (TCS) Assembler performs cell rate de-coupling.
The TCS Assembler then prepares the cells for transport over
the LVDS link by packaging them within link Transport Con-
tainers (TC).
TABLE 1. PDU Cell Format Options
Fixed/
In the up-bridge direction, the TCS Disassemblers unpack the
link transport containers and route the cells to the Multi-port
Traffic Buffer.
Field
Bytes
Variable
Variable
Fixed
User Prepend
Cell Header
UDF1/2
0, 2, 4, 6, 8, 10, 12
4
MPHY address, flow control, and OAM information is embed-
ded within the link transport containers.
Variable
(On/Off)
2, 0 in 16 bit mode
1, 0 in 8 bit mode
6.3.1 Cell Rate Decoupling
In the down-bridge direction, the TCS Assembler inserts idle
cells when no valid traffic cells are available from the FIFO for
onward transmission. In the up-bridge direction, the TCS Dis-
assembler rejects all received idle cells.
Payload
Fid
48
User Appen
iab
0, 2, 4, 6, 8, 10, 12
Although UDF1/2 btes will always be present, the
DS92U6 be programmed to either transport these
bytes or ignore t. If they are to be ignored, then the TCS
strithem out in thdown-bridge direction and the UTOPIA
uridgsection inserts a HEC byte in UDF 1. Otherwise,
thbe trsported transparently the same as any other
PDU .
6.3.2 Link Transport Container (TC)
The ATM cells received on the UTOPIA interface can be stan-
dard or user-specified cells. Cell length is programmable from
52 to 64 bytes. These cells are treated as Protocol Data Units
(PDU), which are packaged into Transport Containers (TC)
for transmission over the serial link. In the reverse direction,
the cell PDUs are unpacked from the link TCs before being
passed out on the UTOPIA interface.
20031605
FIGURE 6. PDU and Link Transport Container Format
Each link TC has an MPHY address byte, two Flow Control
(F) Channel bytes, and a HEC byte in addition to the PDU cell.
The two F1 and F2 bytes per TC constitute the F Channel,
which is used for flow control and OAM purposes over the link.
The TCS uses the HEC byte for container delineation, frame
delineation, and cell header error detection.
TABLE 2. MPHY Byte
Bit
7
6
5
4
3
2
1
0
Function
MPHY Port Address 0–31 Reserved
At the other end of the link, this byte is used to route the in-
coming PDU from the LVDS interface to the appropriate
MPHY port queue.
6.3.3 MPHY Tagging and Routing
In the down-bridge direction, the DS92UT16 adds an addi-
tional byte (MPHY byte) to each PDU. It contains the MPHY
port address associated with that PDU, as shown in Table 2.
6.3.4 Transport Container Delineation and Error
Monitoring
In the down-bridge direction, the device calculates and inserts
the HEC byte using the CRC-8 polynomial x8 + x2 + x + 1 and
optional coset x6 + x4 + x2 + 1 defined in I.432.1 [2.]. The HEC
byte is calculated over the preceding 7–19 bytes, which make
www.national.com
6
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
up the link TC header. To aid delineation at the far end, the
entire contents of the TC, excluding the HEC, are scrambled
and the HEC is calculated on the scrambled TC header. A
scrambler using the pseudo-random sequence polynomial
x31 + x28 + 1 defined in I.432.1 [2.] is used.
Port in question is affected, so this is a non-blocking protocol
over the normal 31 Ports. However, the 8 sub-ports within a
Port do not have individual flow control. This means a sub-
port can block other sub-ports within that Port.
Since a regular flow control opportunity is provided via the F1/
F2 bytes of the F Channel, only a small amount of headroom
need be reserved to allow for latency in this protocol. Fur-
thermore, should a number of PHY ports approach their limit
simultaneously and/or the overall buffer approach a defined
global threshold, a global halt may be issued, temporarily
blocking all traffic.
In the up-bridge direction, the device determines the cell de-
lineation within the received data by locking onto the HEC
byte within the transport container, using the algorithm spec-
ified in I.432.1 [2.].
During normal operation in the up-bridge direction, the device
monitors the HEC bytes for errors, with an option to reject cells
containing errored HEC’s. A performance metric on the num-
ber of errored cells detected is maintained.
The global halt/send command also allows the user to safely
maximize the use of the shared buffer by over-assigning the
memory among the Ports.
Although the HEC byte normally over-writes the UDF1 byte
before cells are passed out over a physical medium, the
DS92UT16 has the option to retain the UDF1 and UDF2 in-
formation fields in order to provide a truly transparent UTOPIA
bridge. If it is not necessary to pass the UDF1/2 bytes be-
tween the ATM and PHY devices at either end of the link, then
the user has the option to suppress them to improve link ef-
ficiency.
The flow control command is illustrated in Table 3. Each port
is assigned a control bit in specified F-bytes within the frame
structure, as shown in Section 6.3.6 F Channel Byte Usage
Within the Frame. ithin the F byte logic, 1 represents a ‘halt’
command to thort d logic 0 represents a ‘send’ com-
mand. A global hdicad by all ports containing a halt
command. e msb Control 3 byte is reserved.
Furthermore, in order to easily share-out the F Channel band-
width between flow control and various OAM functions, the
DS92UT16 uses a frame structure as shown in Section 6.3.6
F Channel Byte Usage Within the Frame. A frame contains
56 transport containers with ATM cells. The start of frame is
indicated by the HEC byte of TC0, which has had the coset
x6 + x4 + x2 + 1 added to it. This differentiates the start of frame
HEC from the normal cell HEC’s.
TABlow Control Coding Within the F Bytes
Flow
Flow
Flow
Flow
Control 3
Control 2
Control 1 Control 0
Pts 30–24 Ports 23–16 Ports 15–8 Ports 7–0
6.3.6 nel Byte Usage Within the Frame
For the maority of time, the F Channel F1/F2 bytes are used
as a flcontrol opportunity, providing a rapid throttle-back
cism as described in Section 6.3.5 Flow Control. In
aon, a small number of F bytes are stolen in a regular
fashion to provide a low bandwidth OAM channel. This is
controlled by the TC number within the frame, as illustrated
in Table 4. Hence, an OAM channel is formed by the F1/F2
bytes in TCs 6, 13, 20, 27, 34, 41, 48 and 55, with the F1/F2
bytes in the remaining containers forming a flow control sig-
nalling channel.
6.3.5 Flow Control
The flow control mechanism within the DS92UT16 enables
applying back-pressure to the source of the ATM cells in
directions. The flow control works independently per
for all 31 queues. It uses a simple ‘halt/send’ comma
PHY Port. At the destination buffer, the fill level of eac
queue is examined against a programmed threld. Shoul
the threshold be reached, a halt command is urnethe
source, which prevents any more cells being sat rt
until a ‘send’ command is subsequently received. Onlhe
7
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
TABLE 4. F Channel Byte Usage Within the Frame
TC0
TC1
TC2
TC3
TC4
TC5
TC6
Flow Control 3
Flow Control 2
Flow Control 1
Flow Control 0
Flow Control 3
Flow Control 2
Flow Control 1
Flow Control 0
Flow Control 3
Flow Control 2
Flow Control 1
Flow Control 0
Alarm/Sig.
Link Labels
TC7
Flow Control 3
Flow Control 2
TC8
Flow Control 1
Flow Control 0
TC9
Flow Control 3
Flow Control 2
TC10
Flow Control 1
Flow Control 0
TC11
Flow Control 3
Flow Control 2
TC12
Flow Control 1
Flow Control 0
TC13
ECC1
ECC2
TC14
Flow Control 3
Flow Control 2
TC15
Flow Control 1
Flow Control 0
TC16
Flow Control 3
Flow Control 2
TC17
Flow Control 1
Flow Control 0
TC18
Flow Control 3
Flow Control 2
TC19
Flow Control 1
Flow Control 0
TC20
ECC3
ECC4
TC21
TC22
TC23
TC24
TC25
TC26
TC27
Flow Control 3
Flow Control 2
Flow Control 1
Flow Control 0
Flow Control 3
Flow Control 2
Flow Control 1
Flow Control 0
Flow Control 3
Flow Control 2
Flow Control 1
Flow Control 0
BIP16
TC28
TC29
TC30
TC31
TC32
TC33
TC34
Flow Control 3
Flow Control 2
Flow Control 1
Flow Control 0
Flow Control 3
Flow Control 2
Flow Control 1
Flow Control 0
Flow Contr3
Flow Con
Flow Control 1
Flow Control 0
Reserved
TC35
Flow Control 3
Flow Control 2
TC36
Flow Control 1
Flow Control 0
TC37
Flow Control 3
Flow Control 2
TC38
Flow Control 1
Flow Control 0
TC39
Floontrol 3
FCol 2
T0
ow Control 1
Flow Control 0
TC41
ECC5
ECC6
TC42
Flow Control 3
Flow Control 2
TC43
Flow Control 1
Flow Control 0
TC44
Flow Control 3
Flow Control 2
TC45
Flow Control 1
Flow Control
TC46
Flow Control 3
Fw Control 2
TC47
Flow Control 1
Flow Control 0
TC48
ECC7
ECC8
TC49
TC50
TC51
TC52
53
TC54
TC55
Flow Control 3
Flow Control 2
Flow Control 1
Flow Control 0
Flow Control 3
Flow Control 2
Flow Control 1
Flow rol 0
Floontrol 3
Fow Control 2
Flow Control 1
Flow Control 0
BIP16
6.3.7 OAM Channel
8.52 RECEIVE PORT B REMOTE STATUS AND
ALRMS—0x7C RBRA for descriptions of these registers.
6.3.7.1 Remote Alarm and Signaling Byte
The function of the ECC signaling bits EVN, ESSA, and ESSB
is described in Section 16.0 Embedded Communication
Channel Operation.
A byte-wide remote alarm and signaling channel is ca
the F1 byte in TC6 as shown in Section 6.3.6 F Channe
Usage Within the Frame. This provides a meaor the d
vice at the far end of the LVDS link to signal an rm condition
to the near end and vise-versa. This byte alne
ECC flow control signals. The format of this byte is as shn
below. Bit [0] is reserved.
6.3.7.2 Link Trace Label Byte
Also, in TC6 a byte-wide link trace label is carried in the F2
byte as shown in Section 6.3.6 F Channel Byte Usage Within
the Frame. This allows the user to verify link connectivity,
which is especially useful when a number of cable links are
being used. The DS92UT16 may be programmed with both a
link label value to transmit and an expected link label. Should
the received link label not match the expected value, an alarm
interrupt may be raised.
TABLE 5. Remote Alarm anyte
Bit
Functi RLOS RLOS RB EV EESS Res
on
7
6
5
4
3
1
0
A
B
A
A
B
The received Link Label byte is software accessible and an
interrupt may be raised on a change of received Link Label
byte. So the Link Label byte may also be used as a user de-
fined channel to pass one byte per frame across the link.
• RLOSA Remote Loss Of Sigat far end device re-
ceive port A.
• RLOSB Remote Loss Of Signal lock at far end device re-
ceive port B.
6.3.7.3 Embedded Communications Channel (ECC)
An Embedded Communications Channel is provided over the
link for software messaging, download, etc. in the F1/F2 bytes
of TCs 13, 20, 41 and 48 as shown in Table 4. The ECC byte
contents are not processed by the DS92UT16. Hence the
DS92UT16 is transparent to and does not restrict the system
messaging protocol.
• RBA
Remote far end device active receive port. Set =
remote receive port B active and Clear = remote
receive port A active.
• RDSLL Remote far end device active port Descrambler
Loss of Lock. Set = Out of lock and Clear = In lock.
• EVN
ECC Tx Data Valid/Null indication.
The ECC consists of an 8 byte Tx Buffer with corresponding
Tx Buffer Ready and Tx Buffer Send flags, and an 8 byte Rx
Buffer with a corresponding Rx Buffer Full Flag. All bytes of
the buffers are software read/write accessible. Tx Buffer
Ready is read only.
• ESSA ECC RxA Stop/Start indication.
• ESSB ECC RxB Stop/Send indication.
The status of the received RLOSA, RLOSB, RBA and RDSSL
bits is reflected in the RARA register for receive port A and in
RBRA for receive port B. See Section 18.33 RECEIVE PORT
A REMOTE STATUS AND ALARMS—0x3C RARA and Sec-
At the ECC transmit side, the reset state sets the Tx Buffer
Ready flag and clears the Tx Buffer Send flag. Then the soft-
ware assembles a message for transmission in the Tx Buffer.
www.national.com
8
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
To send a message, the software simply sets Tx Buffer Send,
which automatically clears Tx Buffer Ready. The contents of
the Tx Buffer are transmitted to the far-end. The Tx Buffer will
automatically be retransmitted until the far-end indicates that
it has been successfully received. When notified by the far
end of successful reception, Tx Buffer Ready is set and an
interrupt raised to the software to indicate successful trans-
mission. A new message may now be assembled in the Tx
Buffer and transmitted by setting Tx Buffer Send. As all the
Tx Buffer bytes are read/ write, the message to be transmitted
can be assembled in any order and read back by the software
before transmission. The same message can be retransmit-
ted simply by setting Tx Buffer Send again.
TABLE 6. F Channel Bandwidth—Bytes
Number of Transport Containers in Frame (8
rows x 7 columns)
56
1
Bytes per Frame for Remote Alarms and
Signalling
Bytes per Frame for Link Label
Bytes per Frame for ECC
1
8
Bytes per Frame Reserved
Bytes per Frame for BIP16
Bytes per Frame for OAM
2
4
16
96
112
Bytes per Frame for Flow Control
Bytes per Frame for F Channel
At the ECC receive side, the reset state clears the Rx Buffer
Full flag. When all 8 bytes of a message have been success-
fully received and stored in the Rx Buffer, the Rx Buffer Full
flag is set and an interrupt raised. As all the Rx Buffer bytes
are read/write, the message can be read in any order by the
software. A new message will not overwrite the current re-
ceived message until the Rx Buffer Full flag is cleared by the
software indicating that the current Rx Buffer has been read
and a new message can be received.
TABLE 7. F Channel Bandwidth—Mbps
Link BW - Mbps
800
56
800
68
Container SizByt
Remote Alrm Bbp
Link LabBW - Mbps
ECC - s
0.26
0.26
2.04
0.51
1.02
4.08
24.49
28.57
0.21
0.21
1.68
0.42
0.84
3.36
20.17
23.53
The ECC data flow is controlled across the link using the EVN,
ESSA, and ESSB bits of the Remote Alarm and Signaling byte
(Section 6.3.7.1 Remote Alarm and Signaling Byte).
Reerved BW - ps
16 W - Mbps
As there are two independent LVDS receive ports, the
DS92UT16 has two independent ECC receive sections.
These are assigned to the LVDS receive ports Port A and Port
B. The ECC of the standby link may therefore be used for
software communication.
W - ps
Flow nl BW - Mbps
F Channl BW - Mbps
Section 16.0 Embedded Communication Channel Operation
describes the operation and control of the ECC in detail.
ABLE 8. F Channel Bandwidth—Percentage
Lk BW - Mbps
800
56
800
6.3.7.4 BIP16
Container Size - Bytes
Remote Alarm BW%
Link Label BW%
ECC BW%
68
A Bit-Interleaved-Parity mechanism provides a live er
formance metric on the LVDS link. A BIP16 value is calc
over a previous block of 28 containers and insed in the F
F2 bytes of containers 27 and 55, as shown iectio3.6
F Channel Byte Usage Within the Frame. At tnde
re-calculated BIP16 values are compared against the-
ceived values. Any bit errors in this comon are cted.
Should the number of errors exceed a threshold,
then an interrupt may be raised.
0.03
0.03
0.26
0.06
0.13
0.51
3.06
3.57
0.03
0.03
0.21
0.05
0.10
0.42
2.52
2.94
Reserved BW%
BIP16 BW%
OAM BW%
Flow Control BW%
F Channel BW%
6.3.7.5 F Channel (Flow Control and OAndwidth
Analysis
6.4 LVDS PHYSICAL INTERFACE
This section analyses the ed by the various
components of the F Channeare dependent up-
on the link bandwidth and the sDU/ATM cells being
carried in the Transport Containers. This illustration is re-
stricted to 800 Mbps and PDU sizes of 52 and 64 bytes. By
adding the 4 bytes for the F Channel, the TCs are then 56 and
68 bytes respectively.
The DS92UT16 provides one dual transmit and two indepen-
dent receive high speed LVDS serial interfaces with 800 Mbps
bandwidth. The LVDS Interface transmits and receives data
over lightly loaded backplanes or up to 10m of cable. The
single transmit block drives two pairs of differential outputs
with independent TRI-STATE® controls for each. The same
data is transmitted over both pairs of transmit pins. The two
serial receive interfaces are completely separate and inde-
pendent and are denoted Port A and Port B. Only one receive
port is selected for traffic at any one time. This is designated
the Active Port. The Standby receive port may be powered
down. Alternatively, the Standby receive port’s OAM channel
can be made available for software communications using the
ECC, and for link performance monitoring. This allows the
condition of the Standby link to be determined. The LOCK
status of both Active and Standby ports is monitored auto-
matically.
Table 6 illustrates the number of bytes used for each function
in the F Channel. The top row gives the total number of Trans-
port Containers per Frame as 56. It then shows the number
of bytes in each Frame for OAM and Flow Control. There is a
total of 112 bytes in each Frame for the F Channel.
Table 7 shows the bit rate used by each portion of the F
Channel. The larger 68 byte container uses a lower proportion
of the channel bandwidth for F Channel functions.
Table 8 shows the percentage of the channel bandwidth used
for each of the functions. The total F Channel bandwidth is
only 3.57% of total bandwidth even with the smaller container
size.
The transmitted data stream contains embedded clock infor-
mation. The receiver’s clock recovery circuit locks onto the
9
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
embedded clock in either a random data pattern, or by in-
structing the transmitter to send SYNCH patterns. The
DS92LV16 can send SYNCH patterns on power-up or when
synchronization is lost. The latter option requires a feedback
loop in either hardware or software between the transmitter
and the receiver, but has the benefit of a faster lock time. The
LOCK status of both receive ports is reflected on external pins
and alarm/status bits that are readable via the microprocessor
port. The LOCK status, along with the currently active port, is
transmitted to the far-end receiver via the Remote Alarm and
Signalling byte of the OAM channel as described in Sec-
tion 6.3.7.1 Remote Alarm and Signaling Byte. The recovered
clocks of both receive ports are available on external pins.
TABLE 9. Software Lock Sequences
Meaning
Sequence
1st write
2nd write
1st write
2nd write
Address
0x00
Data
0x00
0xFF
0xDE
0xAD
Unlock Sequence
0x01
LOCK Sequence
0x00
0x01
Powering down a Receive Port inhibits access to the associ-
ated registers. This feature saves power when a Receive Port
is not in use. It allows re-reading the last value read from a
register associated with that Receive Port and disallows writ-
ing to registers. Receive Port A (RxA) in Power-down mode
inhibits access to registers described in Section 18.21 RE-
CEIVE PORT A LINK LABEL—0x20 RALL to Section 18.39
RECEIVE PORT A BIT ERROR COUNT—0x43 to 0x45
RABEC2 to RABEC0. Receive Port B (RxB) in Power-down
mode inhibits accto registers described in Section 18.40
RECEIVE PORB LK LABEL—0x60 RBLL to Sec-
tion 18.58 RECRT B BIT ERROR COUNT—0x83 to
0x85 RBBEto RC0he contents of these registers
are not losaltered iwer-down mode.
A Loop Timing option is available whereby the LVDS transmit
clock can be sourced directly from the recovered clock of the
active receiver, rather than from the external transmit clock
input pin.
The transmit port and two receive ports may be independently
powered down via microprocessor control. Similarly, the de-
vice may be forced to send SYNCH patterns on the transmit
port via microprocessor control.
To assist in designer testing and system commissioning of the
LVDS interface, the DS92UT16 has a built in BER test facility.
The device may be configured to send a PRBS pattern in
place of ATM cells. At the receiver, the device locks onto this
PRBS pattern and provides an error metric.
6.6 PEORCE MONITORING AND ALARMS
The S92UT16 pdes a number of performance metrics
anlarms to assist in equipment/network management. The
raer can independently enable or disable these
alao raian interrupt. See Section 14.0 Performance
Monitoa detailed description of the Performance Mon-
itoring and General Alarms.
6.5 CPU INTERFACE
The DS92UT16 contains a flexible microprocessor port ca-
pable of interfacing to any common system processor. Via this
port, the system software can customize the behavior of the
device from the various options provided, monitor the system
performance, and activate diagnostic facilities such as
backs and LVDS BER testing.
.7 TT INTERFACE
TEEE 1149.1 JTAG [4.] port on the device provides ac-
cess to the built-in test features such as boundary SCAN,
Internal SCAN and RAM BIST. It may be used to test the de-
vice individually or as part of a more comprehensive circuit
board or system test. (NOTE: The internal SCAN and RAM
BIST functions are not intended for user access. Therefore,
the device user should never assert the Test_se pin.)
In addition to an 8-bit address and 8-bit data bus plus
sociated bus protocol control signals, the port includ
open-drain interrupt signal. The device may assthis sign
on the detection of various alarms within the ice, sas
excessive HEC errors, ECC buffer full/emptof k
etc. Any of the potential internal sources of this interrupt ay
be inhibited individually via an interrupt
6.8 LOOPBACKS
To assist in diagnostic testing, the device provides both LVDS
interface loopbacks and ATM cell loopbacks. The former is
suitable for designer or commission testing when the device
is not passing live traffic. The latter allows cell trace testing
on live traffic. The ATM cell loopback operates by recognizing
the user-defined cell header of the special loopback cells. The
available loopback options are shown in Table 10.
A software lock mechanism is impleent spuri-
ous modification of some of the DS9e acces-
sible registers. A predefined UNLOCK quence is
necessary to allow unrestrictere writccess to the
DS92UT16. A correspondinsequence will pre-
vent any software write acce registers. Read
access is unrestricted excephe next paragraph.
See Table 9 for the LOCK anCK sequences. Only
device configuration registers such as PDU cell length,
UTOPIA interface mode, etc. are protected in this way. All
other registers associated with the ECC, performance moni-
toring and interrupts are always write accessible by the soft-
ware except as noted in next paragraph. See Section 18.1
SOFTWARE LOCK—0x00 to 0x01 SLK0 to SLK1.
In addition to providing a live round trip test via the cell loop-
backs, the DS92UT16 helps pinpoint failures between trans-
mit and receive paths by counting the number of loopback
cells received.
All loopbacks are programmable via the microprocessor in-
terface.
TABLE 10. Loopback Options
LineLB_LVDS
LocalLB_LVDS
Up2Down_ATM
Down2Up_ATM
Physical loopback at the LVDS interface. Loop entering LVDS traffic back out of the device.
Physical loopback at the LVDS interface. Loop exiting LVDS traffic back into the device.
ATM loopback. Route defined cell entering the device at the LVDS interface back out.
ATM loopback. Route defined cell entering the device at the UTOPIA interface back out.
www.national.com
10
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
20031606
FIGURE 7. LVDS Interface and ATM Cell Loack O
7.0 Signal Description
Package ball assignment in Section 20.0 Package
TABLE 11. Pin Descriptio
Description Width
Internal
Bias
Signal Name
Signal Type
Polarity
UTOPIA INTERFACE
U_TxData [15:0]
U_TxParity
Transmit toward the PHY Laye
Transmit data bus parity bit. (od
Transmit cell available - ended.
Transmit cell available ormended.
Enable Data transfers - Exended
16
1
BiDir (Note 2)
BiDir (Note 2)
U_TxCLAV [7:1]
U_TxCLAV [0]
U_TxENB [7:1]
U_TxENB [0]
7
Input (Note 3) Active High
BiDir (Note 1) Active High
Output (Note 3) Active Low
BiDir (Note 2) Active Low
BiDir (Note 2) Active High
BiDir (Note 2)
Pull Down
Pull Down
1
7
Enable Data tranNormaltended.
Transmit Start
1
U_TxSOC
1
U_TxAddr [4:0]
U_RxData [15:0]
U_RxParity
Address of MPHng selected.
Receive fe PHY er data bus.
Receiarity bit. (odd parity)
Receie - Extended.
5
16
1
BiDir (Note 1)
BiDir (Note 1)
U_RxCLAV [7:1]
U_RxCLAV [0]
U_RxENB [7:1]
U_RxENB [0]
U_RxSOC
7
Input (Note 3) Active High
BiDir (Note 1) Active High
Output (Note 3) Active Low
BiDir (Note 2) Active Low
BiDir (Note 1) Active High
BiDir (Note 2)
Pull Down
Pull Down
Receive ble - Normal/Extended.
Enable Data transfers - Extended.
1
7
Enable Data transfers - Normal/Extended.
Receive Start Of Cell.
1
1
U_RxAddr [4:0]
U_UDBClk
Address of MPHY device being selected.
UTOPIA Down Bridge - Input transfer clock.
UTOPIA Up Bridge - Output transfer clock.
5
1
Input (Note 4)
U_UUBClk
1
Input (Note 5)
LVDS INTERFACE
LVDS_ADout[+,−]
LVDS_BDout[+,−]
LVDS_ADenb
LVDS_BDenb
LVDS_Synch
A Serial data differential outputs.
B Serial data differential outputs.
Serial transmit data A output enable.
Serial transmit data B output enable.
2
2
1
1
1
Output
Output
Input
Input
Input
Active High
Active High
Active High
Pull Up
Pull Up
External control to transmit SYNCH patterns on
serial interface.
Pull Down
11
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Internal
Bias
Signal Name
LVDS_TxClk
Description
Width
Signal Type
Polarity
Transmit clock.
1
1
2
1
1
1
1
2
1
1
1
1
Input
Input
LVDS_TxPwdn
LVDS_ADin[+,−]
LVDS_ALock_n
LVDS_ARxClk
LVDS_ARefClk
LVDS_APwdn
LVDS_BDin[+,−]
LVDS_Block_n
LVDS_BRxClk
LVDS_BRefClk
LVDS_BPwdn
Transmit section power down
PortA Serial data differential inputs.
PortA Clock recovery lock status
PortA Recovered clock.
Active Low
Pull Up
Input
Output
Output
Input
PortA Reference clock for receive PLLs.
PortA Power Down.
Input
Active Low
Active Low
Pull Up
Pull Up
PortB Serial data differential inputs.
PortB Clock recovery lock status.
PortB Recovered clock.
Input
Output
Output
Input
PortB Reference clock for receive PLLs.
PortB Power Down.
Input
CPU & GENERAL CONTROL
CPU_cs
Select signal used to validate the address bus for
read and write data transfers.
1
1
put
Input
Input
Active Low
Active Low
CPU_rd (CPU_ds)
CPU_wr (CPU_rnw)
Read or Data Strobe, depending on
CPU_BusMode.
Write or Read/Write, depending on CPU_BusMod
Active Low
(Write)
CPU_int
Interrupt request line.
1
8
1
4
1
Output
BiDir
Input
Input
BiDir
Input
Active Low
Open Drain
CPU_Data[7:0]
CPU_Addr[7:0]
CPU_BusMode
GPIO [3:0]
Data bus.
Address bus.
Mode select for bus protocol.
General Purpose Input/Output.
Reset min pulse is 2X slowest c
Pull Down
Pull Up
Reset_n
Active Low
Active Low
JTAG TEST INTERFACE
JTAG_CLK
Test clock.
1
1
1
1
1
1
Input
Input
Input
Input
Output
Input
JTAG_Reset
JTAG_TMS
JTAG_TDI
Test circuit reset.
Pull Up
Pull Up
Test Mode Select.
Test Data In.
JTAG_TDO
Test_se
Test Data Out.
SCAN enable ing test only)
Active High
Pull Down
TOTAL PIN COUNT
Total Functional I/O
LVDS VDD/VSS
CVDD/CVSS
133
3.3V r analog and digital
2.5V Cr digital functions
3.3V I/O poring
46
6
IOVDD/IOVSS
Total Power
No Connect
Total Pins
8
60
3
No signal connected to this pin
196 LBGA, 15x15 mm, 1.0 mm ball pitch
196
Note 1: These pins are Inputs in ATM Layer mode and Outputs PHY Layer mode
Note 2: These pins are Outputs in ATM Layer mode and Inputs PHY Layer mode.
Note 3: These pins are only used in PHY layer mode, Extended 248 PHY mode. In Normal 31 PHY mode or ATM layer mode, they must be unconnected.
Note 4: In PHY layer mode this is the Utopia TxClk and in ATM layer mode this is the Utopia RxClk.
Note 5: In PHY layer mode this is the Utopia RxClk and in ATM layer mode this is the Utopia TxClk.
www.national.com
12
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
In 16-bit mode of the full U_TxData[15:0] and
U_RxData[15:0] are valid and parity is calculated over all
bits of the data buses.
One ATM Layer can communicate with up to 31 PHY ports
using the MPhy address busses U_TxAddr[4:0] and
U_RxAddr[4:0] and the control signals U_TxCLAV[0],
U_RxCLAV[0], U_TxENB[0] and U_RxENB[0].
U_TxCLAV[7:1], U_RxCLAV[7:1], U_TxENB[7:1] and
U_RxENB[7:1] are not used.
All Queues from 30 to 0 of the MTB may be used. There
is one queue for each MPhy address so the use of the
queues will depend on the connected ports list defined by
the UCPL3–UCPL0 registers.
Uses the connected ports list defined by the UCPL3-
UCPL0 registers. In ATM mode, these registers are used
to determine the ports that should be polled. In PHY mode,
these registers are used to determine which MPhy
addresses the vice should respond to during polling.
The connecsubrt list defined in the UCSPL register
is not used.
The subort addration defined by USPAL and
USPAgisters is nused.
8.0 UTOPIA Interface Operation
This section describes the operation of the UTOPIA Interface
of the DS92UT16. The UTOPIA interface mode of operation
is defined in the UTOPIA Configuration (UCFG) register de-
scribed in Section 18.59 UTOPIA CONFIGURATION—0xA0
UCFG. The format of the PDU cells carried over this interface
is defined in the PDU Configuration (PDUCFG) register de-
scribed in Section 18.5 PDU CONFIGURATION—0x05
PDUCFG.
•
•
•
The interface can operate in ATM layer mode or PHY layer
mode. When operating as a Level 2 ATM layer interface, the
protocol can be extended to cope with up to 248 PHY ports
rather than the maximum 31 allowed by the standard Level 2
definition. This Extended Level 2 mode is achieved with eight
CLAV and eight ENB signals.
•
On power up the device defaults to ATM layer mode. To pre-
vent potential contention on the Utopia interface signals, all
the Utopia pins which are bidirectional are configured as out-
puts in tri-state mode and the Utopia interface block is dis-
abled. The user must select the device operating mode, ATM
layer or PHY layer, by writing the appropriate value to the
UMODE bit of the UCFG register before enabling the Utopia
interface block and releasing the Utopia interface pins. En-
abling the Utopia interface and releasing the Utopia pins is
achieved by setting the UBDEN bit of the UCFG register.
•
•
•
The LAde bits CLVM[1:0] of the UCFG register
sould be defas CLVM[1:0] = 00.
Thonfiguration of the inputs/outputs of the UTOPIA Level
erfe for ATM Layer mode and PHY Layer mode is
shFig8. The main difference is that in ATM mode
the CLs are inputs and the MPhy Address and ENB
pins are otputs; whereas in PHY mode, the CLAV pins are
outputand the MPhy Address and ENB pins are inputs.
8.1 UTOPIA BASIC LEVEL 2 MODE - 31 PORTS (Default
Mode)
In UTOPIA Level 2 mode:
•
8-bit or 16-bit data buses are controlled by the BWIDTH
bit of the UCFG register. In 8-bit mode only
tat in ATM Layer mode the DS92UT16 does not gen-
erthe UTOPIA clocks and must be supplied with these
clocks just as in PHY mode.
U_TxData[7:0] and U_RxData[7:0] are valid; parity is
calculated and checked only over these bits of the
buses and the upper bits of the data buses are no
20031607
FIGURE 8. Basic UTOPIA Level 2 UMODE Configuration
8.1.1 ATM Polling
connected will be polled. The connected ports list defined in
the UCPL3–UCPL0 registers is used to determine which ports
are connected. The PHY ports respond only on U_TxCLAV
When configured as an ATM Layer device, the DS92UT16
polls the connected PHY ports using the MPhy address
busses U_TxAddr and U_RxAddr. Only those ports which are
13
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
[0] and U_RxCLAV[0]. On reset the UCPL3–UCPL0 registers
are all set to 0xFF so the DS92UT16 will poll all ports.
U_TxAddr[4:0] and U_RxAddr[4:0], and the control signals
U_TxCLAV[7:0], U_RxCLAV[7:0], U_TxENB[7:0] and
U_RxENB[7:0]. In PHY mode, the DS92UT16 behaves as
a standard Level 2 device and only 31 ports are needed
using the MPhy address busses U_TxAddr[4:0] and
U_RxAddr[4:0], and the control signals U_TxCLAV[0],
U_RxCLAV[0], U_TxENB[0] and U_RxENB[0].
All Queues from 30 to 0 of the MTB may be used. There
is one queue for each MPhy address so the use of the
queues will depend on the connected ports list defined by
the UCPL3–UCPL0 registers.
The connected ports list defined by the UCPL3–UCPL0
registers and the connected sub-port list defined in the
UCSPL register are used. In ATM mode, these registers
are used to determine which ports should be polled. In
PHY mode, these registers are used to determine which
MPhy addresses the device should respond to during
polling.
The sub-pordreocation defined by USPAL and
USPAM regisused ATM mode to determine the
location the 3-ubort address in the PDU cell. In
PHY me these regrs are not used.
8.1.2 PHY Polling
When configured as a PHY Layer device the DS92UT16 is
polled by the connected ATM device. During polling the
DS92UT16 will only respond to MPhy addresses, on
U_TxAddr and U_RxAddr, which are defined as connected.
The connected ports list defined in the UCPL3–UCPL0 reg-
isters is used to determine which ports are connected. On
reset the UCPL3–UCPL0 registers are all set to 0xFF so the
DS92UT16 will respond to all MPhy addresses during polling.
The DS92UT16 responds only on U_TxCLAV[0] and U_Rx-
CLAV[0].
•
•
NOTE: There must always be at least one connected port
defined in the UCPL3–UCPL0 registers. If no ports are to be
connected then use Configuration Traffic Inhibit mode de-
scribed in Section 10.0 Configuration and Traffic Inhibit Op-
eration.
•
•
8.2 UTOPIA EXTENDED LEVEL 2 MODE - 248 PORTS
In UTOPIA Extended Level 2 mode:
•
8-bit or 16-bit data buses are controlled by the BWIDTH
bit of the UCFG register. In 8-bit mode, only
The Aode bits CLVM[1:0] of the UCFG register
should be dd as CLVM[1:0] = 11.
U_TxData[7:0] and U_RxData[7:0] are valid; parity is
calculated and checked only over these bits of the data
buses. In 16-bit mode, the full U_TxData[15:0] and
U_RxData[15:0] are valid; parity is calculated and checked
over all bits of the data buses.
Thonfiguration othe inputs/outputs of the UTOPIA Level
2 terfafor ATM Layer mode and PHY Layer mode is
sFigu9.
•
In ATM mode, the DS92UT16 can communicate with up
to 248 PHY ports using the MPhy address busses
20031608
FIGURE 9. Extended UTOPIA Level 2 UMODE Configuration
The main difference is that in ATM mode the CLAV pins are
inputs and the MPhy Address and ENB pins are outputs,
whereas in PHY mode the CLAV pins are outputs and the
MPhy Address and ENB pins are inputs. Also, in ATM mode
all eight CLAV and ENB pins are used, but in PHY mode only
one of the CLAV and ENB pins are used.
Note that in ATM Layer mode the DS92UT16 does not gen-
erate the UTOPIA clocks but must be supplied with these
clocks just as in PHY mode.
www.national.com
14
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
8.2.1 ATM Polling
8.2.3 Sub-Port Address
When configured as an ATM Layer device, the DS92UT16
polls the connected PHY ports using the MPhy address
busses U_TxAddr and U_RxAddr. Only those ports which are
connected will be polled. The connected ports list defined in
the UCPL3–UCPL0 registers is used to determine which ports
are connected. The PHY ports respond on U_TxCLAV[7:0]
and U_RxCLAV[7:0]. The MPhy address determines the Port
and the CLAV pin number determines the sub-port. Therefore
up to 8 sub-ports may be connected to a port. Polling of a
single MPhy address will get eight responses on the eight
CLAV lines. The DS92UT16 uses the connected sub-port list
defined in the UCSPL register to determine which of these
eight sub-port responses are valid. On reset, the UCPL3–
UCPL0 registers are all set to 0xFF and the UCSPL register
is set to 0x01, so the DS92UT16 will poll all ports and assume
only sub-port zero is connected.
The operation of the sub-port address is illustrated in Figure
10. To use the Extended Level 2 mode that allows addressing
up to 248 Ports, the ATM Layer (that which drives the
DS92UT16 in PHY mode) must be capable of inserting a three
bit sub-port address in the PDU cell for use by the DS92UT16.
This 3-bit sub-port address must reside in either the User
Prepend, Cell Header, or UDF bytes. It’s location is defined
in the UTOPIA Sub-Port Address Location (USPAL) and
UTOPIA Sub-Port Address Mask (USPAM) registers. The
USPAL register defines which byte of the User Prepend, Cell
Header, or UDF, contains the address and the USPAM reg-
ister defines which three bits of that byte are the sub-port
address.
Transmit Path Example: The MPhy address is interpreted
as the Port address. So, a cell destined for the PHY desig-
nated as Port 0 Sub-Port 7 has the three bit sub-port address
7 (binary “111”) inted into the defined sub-port address lo-
cation of the PDcell the ATM layer head-end. It is then
transmitted to thUT1n PHY mode using MPhy ad-
dress 0. ThS92Uin HY mode does not examine the
sub-port ress becaall cells are transmitted down-
bridge a
8.2.2 PHY Polling
When configured as a PHY Layer device, the DS92UT16 is
polled by the connected ATM device. During polling, the
DS92UT16 will only respond to MPhy addresses on
U_TxAddr and U_RxAddr, which are defined as connected.
The connected ports list defined in the UCPL3–UCPL0 reg-
isters is used to determine which ports are connected. On
reset the UCPL3–UCPL0 registers are all set to 0xFF so the
DS92UT16 will respond to all MPhy addresses during polling.
At the far end, tS92UT16 in ATM mode extracts the sub-
porddress. This iused to determine which sub-port CLAV/
Esigls the destination PHY is connected to. A port ad-
d0 and a sub-port address of 7 means that the desti-
natioY MPhy address 0 attached to U_TxENB[7] and
U_TxCL]. The cell is then transmitted to that PHY.
NOTE: There must always be at least one connected port
defined in the UCPL3–UCPL0 registers. If no ports are to be
connected then use Configuration Traffic Inhibit mode de-
scribed in Section 10.0 Configuration and Traffic Inhibit Op-
eration.
15
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
20031609
FIGURE 10. Sub-Port Address Operation
Receive Path Example: The DS92UT16 in ATM mode re-
ceives a cell from the PHY with MPhy address 0 attached to
U_RxENB[6] and U_RxCLAV[6] and designates it as from
Port 0 Sub-Port 6. The DS92UT16 inserts the sub-port ad-
dress 6 (binary “110”) into the sub-port address location of the
received PDU. Then this PDU is transmitted to the head-end.
The head-end ATM layer device must extract this sub-port
address from the PDU to determine the full address of the
originating PHY.
busses. If a bit location in the UCPL3–UCPL0 registers is set,
then that Port is connected. The sub-ports of the connected
Port are defined by the UCSPL register. If a bit location in the
UCSPL register is set, then that sub-port is connected.
In Figure 11, the registers are set as follows: UCPL3 = UCPL2
= UCPL1 = 0xF, UCPL0 = 0xFD, and UCSPL = 0xEF.
With bit 1 of UCPL0 cleared, then Port 1 is not connected.
This means that none of the eight sub-ports of Port 1 are con-
nected. So Port 1 Sub-port 7, Port 1 Sub-port 6, Port 1 Sub-
port 5, Port 1 Sub-port 4, Port 1 Sub-port 3, Port 1 Sub-port
2, Port 1 Sub-port 1, and Port 1 Sub-port 0 are not connected.
Port 1 will therefore, not be polled.
8.2.4 Connected Port and Sub-Port Lists
Figure 11 illustrates the usage of the connected port list reg-
isters (UCPL3–UCPL0) and the connected sub-port list reg-
ister (UCSPL). In this case, the DS92UT16 in ATM mode
defines Port 1 and Sub-port 7 as not connected.
With bit 7 of UCSPL cleared, then sub-port 7 is not connected.
This means that sub-port 7 for all possible 31 ports is not
connected. So Port 31 Sub-port 7, Port 30 Sub-port 7, Port
29 Sub-port 7,......and Port 0 Sub-port 7 are not connected.
The UCPL3–UCPL0 registers contain 31 bits corresponding
to the 31 possible Ports addressed by the MPhy address
www.national.com
16
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Therefore, clearing a bit in the UCPL3–UCPL0 registers will
disconnect 8 possible PHY port locations and clearing a bit in
the UCSPL register will disconnect 31 possible PHY port lo-
cations.
20031610
FIGURE 11. ConnecteConnected Sub-Port Usage
The MTB Queue Threshold, MTBQT30–MTBQT0 registers
define the maximum size in PDU cells of each of the 31
queues. If all 31 queues are being used it is recommended
that the threshold be left at the default of 4 cells. If less than
31 queues are in use then the queue thresholds may be raised
if required. The recommended maximum queue thresholds
are given in Table 12. These are recommended maximum
thresholds only.
9.0 MTB Queue Configuratio
9.1 SINGLE BRIDGE MTB CONFIGUN
The Multi-port Traffic Buffer is a 160 uffer that
is shared across as many as 31 Port qus a single
queue per MPHY address.
In the up-bridge direction, a low control protocol
(described in Section 6.3.5 ) prevents queue
overflow. Each Port has a prpper fill threshold.
Should any queue reach this hold, back-pressure
is applied over the serial link, via the flow control mechanism,
to the far end (transmitting) device. The transmitting device
uses the normal UTOPIA flow control handshaking to prevent
any more cells being transferred to that MPHY and thus pre-
vents overflow.
It is further recommended that any queue that is not being
used is set with a threshold of zero. When a queue has
reached its programmed threshold the device flow control
mechanism will prevent the far end device from accepting
cells for that MPHY address. Therefore, by setting the thresh-
old of an unused queue to zero, it prevents the UTOPIA
interface of the far end device from accepting cells for that
MPHY address by either, not asserting the CLAV for that
MPHY address when in PHY Mode, or not selecting that
MPHY address when in ATM mode.
With link-list buffers, each queue may be over-assigned mem-
ory space, working on the assumption that not every queue
will back up simultaneously. To accommodate the rare occa-
sions where the buffer as a whole approaches full but indi-
vidual queues are below their full threshold, the device also
compares the overall buffer fill against a threshold. Should the
overall buffer approach overflow, the flow control mechanism
provides a global ‘halt’ command to ensure that no cells will
be lost.
Also, note that setting a threshold of zero will cause the cor-
responding Queue Full bit in the MTBQFL3–MTBQFL0 reg-
isters to be continuously set for that queue.
17
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
TABLE 12. Recommended Maximum MTB Queue Thresholds
Number of
Queues in Use
Recommended
Threshold
Number of
Queues in Use
Recommended
Threshold
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
4
4
15
14
13
12
11
10
9
15
16
5
18
5
20
5
23
6
26
6
29
7
8
34
7
7
39
8
6
47
9
5
58
10
10
11
12
4
4
74
100
100
154
1
9.2 MULTIPLE BRIDGE MTB CONFIGURATION
10 Configuration and Traffic
InhibOperation
Modifying some device configuration settings should not be
arrieout while traffic is flowing. A mechanism to inhibit traf-
frovided, which should be used when changing any of
the settings contained in the PDUCFG, UCFG, USPAL or
USPAM registers.
When UTOPIA-LVDS bridges are used in parallel as in Figure
5 the PHY mode DS92UT16s will forward all cells on the
UTOPIA TxData bus across the LVDS bridge. Cells that are
not addressed for PHYs on a bridge will accumulate in the
MTBs of the ATM mode DS92UT16s. If too many cells accu-
mulate the MTB will become full and traffic will be sto
over that bridge. To prevent filling the MTBs PHY p
dresses must be distributed evenly across all bridge
system. Additionally, the MTB queue threshold of any
not in the Connected Ports List should be set to in order
limit the number of cells that can accumulate.
The Traffic Inhibit mechanism causes traffic to stop. The
UTOPIA interface will stop transmitting and receiving cells,
the LVDS transmit section will transmit Idle cells, and the in-
coming cells on the active LVDS receive port will be discard-
ed. It is controlled by the Configuration Traffic Inhibit (CTI) and
Traffic Inhibit Status (TIS) bits of the General Control and
Status (GCS) register, see Section 18.3 GENERAL CON-
TROL AND STATUS—0x03 GCS.
Table 13 lists the minimum number of ports thbs-
signed to each bridge for the total number of ports in he
system.
TABLE 13. Minimum Ports per B-Bridge
System
The processor should set the CTI bit before changing any of
the PDUCFG, UCFG, USPAL or USPAM register settings.
This will initiate the Traffic Inhibit mechanism. The TIS bit
should then be polled. When the TIS bit is set, then traffic is
inhibited.
Total Ports Used
MinimNumber of
rts per Bridge
31
30
29
28
27
26
25
24
23
22
8
7
6
5
4
3
2
1
The MTB and FIB queues MUST be flushed at this stage. Use
the FIBFL and MTBFL bits of the QFL register described in
Section 18.69 QUEUE FLUSH—0xD8 QFL to accomplish the
queue flushing. Set these bits to flush the queues and then
poll these bits to determine when flushed. The queue flushing
is complete when these bits are clear.
The device can now be reconfigured safely. When configu-
ration is completed, then the CTI bit can be cleared by the
processor and normal operation resumed.
Note that the CTI bit is set on either power up or software
reset (See Section 18.3 GENERAL CONTROL AND STATUS
—0x03 GCS) and therefore the Traffic Inhibit mechanism is
active. When initialization of the device registers is completed
by the processor the CTI bit should be cleared.
Note that the devices at both ends of the LVDS link must be
configured with the same values for the PDUCFG, USPAL,
and USPAM registers for correct operation.
www.national.com
18
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Note that when configuration of both ends of the link is com-
plete then CTI must not be disabled for at least two PDU
transport times (i.e. the length of time it takes to transport two
PDUs over the LVDS link). This “CTI disable hold-off period”
allows all PDUs of the old configuration to be received and
discarded correctly. If this hold-off period is not respected
then an idle cell PDU of the old PDU configuration may arrive
at a device programmed with the new PDU configuration and
incorrectly be interpreted as a valid cell.
the ECC, Flow Control, BIP, Remote Alarm and Signalling
and Link Label bytes (Section 6.3.6 F Channel Byte Usage
Within the Frame). If Frame delineation is lost then
•
•
•
the received ECC bytes are considered invalid and are
assumed to retain the last valid values received
the Flow Control bytes are considered invalid and are
assumed to be all ones, i.e. ‘halt’ all ports
the Remote Alarm and Signalling byte is considered
invalid and is assumed to retain the last valid value
received
Note that any change in the PDU configuration which
changes the byte location of the TC HEC byte will cause the
far end device to fall out of TC delineation. See Figure 6.
•
and the Link Label byte is considered invalid and is
assumed to retain the last valid value received.
TC and Frame delineation is achieved using the HEC bytes
of the TC’s. The HEC bytes are not scrambled.
11.0 Cell/Frame Delineation and
Descrambler Operation
Each of the two Transmission Convergence Sub-Layer (TCS)
DisAssemblers receives 16-bit data from the associated
LVDS receive section. The TCS DisAssembler must first find
the Transport Container (TC) boundaries, then the data can
be descrambled and the Frame boundaries found. Once this
has been achieved the received data can be disassembled.
The Descrambler is loaded with the Scrambler sequence on
start-up to achieve lock. The operation of these blocks is de-
scribed below.
11.1 TRANSPOCOTAINER DELINEATION
At the receive end e LVlink, the data will appear as a
stream witno indicof Transport Container (TC) or
frame bories. TC delneation is achieved by finding cor-
rect HEs oincoming data stream. The TC delineation
state diagram is wn in Figure 12.
After achieving TC delineation and the Descrambler locking,
then the cell data within each TC is valid and can be passed
to the MTB. If TC delineation is lost, or the Descrambler is not
locked, then cell data is invalid and is not passed to the MTB.
Frame delineation must be achieved before the bytes of the
F Channel are considered valid. The F Channel consists of
20031611
FIGURE 12. State Diagram for TC Delineation
C_HUNT—On reset, the TC delineation state machine starts
in the C_HUNT state and TC delineation has not been
achieved. In the C_HUNT state, a HEC is calculated word by
word on a data stream equal in length to the TC Header and
compared against the next received byte. The length of the
TC header is derived from the PDUCFG register (Section 18.5
PDU CONFIGURATION—0x05 PDUCFG). This process is
repeated until a correct HEC is detected. When a single cor-
rect HEC has been detected the state machine moves into
the C_PRESYNC state.
C_PRESYNC—In C_PRESYNC, if a correct HEC is found
DELTA consecutive times then the state machine moves to
the C_SYNC state and the system has achieved TC delin-
eation. If an erred HEC is detected during the C_PRESYNC
state, the process moves back to the C_HUNT state.
C_SYNC—In the C_SYNC state, TC delineation is assumed
to be lost if an erred HEC is obtained on ALPHA consecutive
occasions. The state machine will move back to the C_HUNT
state.
The values of DELTA and ALPHA are programmable inde-
pendently for Port A and Port B. They are contained in the
RACDT and RBCDT registers (Section 18.36 RECEIVE
Note that depending on the length of the TC and the length of
the TC Header it may be necessary to word slip after a pre-
defined number of HEC calculations in order to obtain a
correct HEC.
PORT
A
CELL DELINEATION THRESHOLDS—0x40
RACDT and Section 18.55 RECEIVE PORT B CELL DELIN-
19
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
EATION THRESHOLDS—0x80 RBCDT). On reset, DELTA
= 8 and ALPHA = 7.
This is the standard coset which may be added to all HEC’s
(CDIS bit in the LKSC register in Section 18.8 LINK STATUS
AND CONTROL—0x08 LKSC). If the coset is already added
to all HEC’s, then it is added again to the HEC of TC0. This
ensures that the HEC of TC0 can always be differentiated
from that of other TC’s.
11.2 FRAME DELINEATION
Once the system has achieved TC delineation, the Frame
delineation process can begin. The Frame delineation pro-
cess is achieved by checking for correct HEC’s with the added
coset x6 + x4 + x2 + 1. This added coset differentiates ‘Start
of Frame’ TC HEC’s from normal TC HEC’s. Only the HEC of
TC0 has this added coset.
The Frame delineation state diagram is shown in Figure 13.
20031612
FIGURE 13. State Diagram fme Delineation
F_HUNT—On reset, the Frame delineation state m
starts in the F_HUNT state and Frame delineation h
been achieved. Each received HEC is monitored determ
if it has the added coset and is therefore the rt Of Frame
(SOF) HEC. When a single correct SOF HEC ee
state machine enters the F_PRESYNC state.
After reset, the Descrambler expects the far-end transmitting
device to send it’s Scrambler sequence embedded in Idle
cells so that the Descrambler can synchronize (lock) to it. This
scrambler-sequence transfer is achieved by means of the
Remote Descrambler Loss of Lock bit (RDSLL) in the Remote
Alarm and Signalling byte (Section 6.3.7.1 Remote Alarm and
Signaling Byte). This received bit is stored as the RARDSLL
bit of the RARA register for Port A (Section 18.33 RECEIVE
PORT A REMOTE STATUS AND ALARMS—0x3C RARA)
and the RBRDSLL bit of the RBRA register for Port B (Sec-
tion 18.52 RECEIVE PORT B REMOTE STATUS AND
ALARMS—0x7C RBRA).
F_PRESYNC—In the F_PRESYNC sta correOF
HEC is found SIGMA consecutive tie machine
moves to the F_SYNC state and thd to have
achieved Frame delineation. If an errorEC is de-
tected during the F_PRESYNte thte machine
moves back to the F_HUNT
The lock status of the Descrambler is transmitted to the far-
end device as the RDSLL bit. If the Descrambler is out of lock,
then the transmitted RDSLL = 1. At the far end device, this is
stored as RARDSLL or RBRDSLL, depending on which port
it is connected to. When this bit is set for the active receive
port, it causes the TCS Assembler to transmit the Scrambler
sequence embedded in Idle cells. The Descrambler loads this
sequence and attempts to lock to it. Once the Descrambler
locks to this sequence, it clears the RDSLL bit transmitted to
the far-end device, which causes the far-end device to stop
sending the Scrambler sequence embedded in Idle cells and
to begin sending real traffic cells.
F_SYNC—In the F_SYNC delineation will be
assumed to be lost if an erris obtained on MU
consecutive occasions. The stne will move back to
the F_HUNT state.
The values of SIGMA and MU are programmable indepen-
dently for Port A and Port B. They are contained in the RAFDT
and RBFDT registers (Section 18.37 RECEIVE PORT A
FRAME DELINEATION THRESHOLDS—0x41 RAFDT and
Section 18.56 RECEIVE PORT B FRAME DELINEATION
THRESHOLDS—0x81 RBFDT). On reset, SIGMA = 8 and
MU = 7.
11.3 DESCRAMBLER OPERATION
The Descrambler synchronization state diagram is shown in
Figure 14.
Once TC delineation has been obtained, the Descrambler
synchronization can begin.
www.national.com
20
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
20031613
FIGURE 14. State Diagram for Descrambler nchron
D_HUNT—On reset, the Descrambler synchronization state
machine starts in the D_HUNT state and the Descrambler is
not in Lock. When TC delineation has been achieved, the
transmitted Scrambler sequence from the far-end device is
loaded into the Descrambler. The state machine enters the
D_PRESYNC state.
•
PDU length bytes (maximum possible) = 32 cycles
bit data pat
ax length =PDU + 4 bytes = 34 cycles
e = 5TC = 1904 cycles
•
•
Once S Receive input PLL locks to the incoming serial
data streaand recovers data bits, the DS92UT16 searches
for a TC HEC byte. Assuming that the DS92UT16 just missed
HEwhen the LVDS PHY locked, it will take a minimum of
oC to find the HEC byte. Next, the DS92UT16 will con-
tinue finding correct TC HECs until it matches the number in
the confidence counter (default setting is DELTA = 8). The TC
delineation is now in sync.
D_PRESYNC—The received scrambler sequences and pre-
dicted sequences are compared for each TC. For each cor-
rect prediction, a confidence counter increments, and for each
incorrect prediction, the confidence counter is decreme
When the confidence counter reaches RHO, then th
machine moves to the D_SYNCH state and the system
to have achieved scrambler Lock. If the confidence co
reaches zero then the state machine moves bacthe HUN
state.
Next, the UT16 will start looking for SOF HECs that indicate
a start-of-frame. Assuming a SOF has just passed, the max
time to find an SOF should be 1 Frame. Now the UT16 will
collect frames until the correct number matches the confi-
dence counter (default setting is SIGMA = 8). When the
correct number of SOFs matches the confidence counter, the
frame delineation is in sync.
D_SYNC—The comparison of received ler e-
quences and predicted sequences is repeated for ch
Frame. For each correct prediction, a ence coer is
decremented, and for each incorrehe confi-
dence counter is incremented. The coter has a
lower limit of zero. If the confidence counts PSI, then
the state machine moves back _HUtate and the
Descrambler is out of Lock.
Simultaneous with the frame delineation, the DS92UT16 will
synchronize and lock the descrambler. The lock procedure
begins with the transmitting DS92UT16 sending the scram-
bler sequence in idle cells. It does this automatically on reset
or start-up until it receives the cleared RDSLL bit in the Re-
mote Alarm and Signaling byte. After TC delineation occurs
at the receive end, the DS92UT16 will count correct scrambler
sequence predictions until it matches the confidence counter
(default setting is RHO = 8). When the correct number of
scrambler sequence predictions matches the confidence
counter, the descrambler is synchronized and the receiving
DS92UT16 clears the RDSLL bit.
The state machine will also to D_HUNT if TC
delineation is lost.
The values of PSI and RHO are pmmable independently
for Port A and Port B. They are contained in the RADSLKT
and RBDSLKT registers (Section 18.38 RECEIVE PORT A
DESCRAMBLER LOCK THRESHOLDS—0x42 RADSLKT
and Section 18.57 RECEIVE PORT B DESCRAMBLER
LOCK THRESHOLDS—0x82 RBDSLKT). On reset PSI = 8
and RHO = 8.
In this example, the time it takes for a receiving DS92UT16 to
synchronize to the transmitting DS92UT16, after the PLL
locks, is approximately determined by the following calcula-
tion. This time will differ according to PDU length and the
value programmed as the confidence thresholds.
11.4 ANALYZING LOCK AND SYNCHRONIZATION TIME
After the DS92UT16 LVDS receiver’s PLL locks onto the in-
coming serial data stream and begins to recover data, it must
achieve TC lock, then frame lock and descrambler lock before
transferring cells. The number of cycles to complete this syn-
chronization depends on the PDU length as well as the byte
location in the TC and frame where the receiver begins syn-
chronizing.
(1+8) TC = 9 (34 cycles) = 306 cycles for TC sync, and (1+8)
(1 frame) = 9 (1904 cycles) = 17136 cycles. This is a total of
17442 cycles and assumes that the descrambler lock occurs
during the 8 frames it takes for the frame delineation to occur.
Here are the assumptions for this example on calculating the
synchronization time.
21
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
random data depends on the data patterns and, therefore, the
lock time is unspecified.
12.0 LVDS Interface Operation
The LVDS interface combines a transmit serializer and two
receive deserializers. The serializer accepts 16- bit data from
the TCS Assembler block and transforms it into a serial data
stream with embedded clock information. Each deserializer
recovers the clock and data from the received serial data
stream to deliver the resulting 16-bit wide words to the corre-
sponding TCS DisAssembler block.
In order to lock to the incoming LVDS data stream, the De-
serializer identifies the rising clock edge in a sync-pattern and
will synchronize to the embedded clock in less than 5 µs. If
the Deserializer is locking to a random data stream from the
Serializer, then it performs a series of operations to identify
the rising clock edge and locks to it. Because this locking pro-
cedure depends on the data pattern, it is not possible to
specify how long it will take. At the point where the Port A
Deserializer’s PLL locks to the embedded clock, the
LVDS_ALock_n pin goes low, the LLOSA bit of the ETXRXA
register may be cleared and valid data is presented to the TCS
DisAssembler block. Note that the LVDS_ALock_n signal is
synchronous to valid data being presented to the TCS Dis-
Assembler.
The LVDS interface has a Transmit serializer block and two
Receive deserializer blocks that can operate independent of
each other. The transmit data is duplicated over two differen-
tial output pairs with independent tri-state controls. The trans-
mit block has a power-down control. Each receiver has a
power down control and the two output stages have indepen-
dent tri-state control. These features enable efficient opera-
tion in various applications.
The user’s application determines whether sync-patterns or
lock to random das the preferred method for synchroniza-
tion. If sync-pans preferred, the associated Port A
deserializer’s LVock_pin is a convenient way to pro-
vide control the L_nch pin, possibly via the RAR-
LOSA (Rve Port Aemote Loss Of Signal) bit of the
RARA rsee Section 18.33 RECEIVE PORT A RE-
MOTE STATUD ALARMS—0x3C RARA.
The serializer and deserializer blocks each have three oper-
ating states. They are the Initialization, Data Transfer, and
Resynchronization states. In addition, there are two passive
states: Powerdown and TRI-STATE.
The following sections describe each operating mode and
passive state. For clarity these descriptions refer only to the
receive Port A. The operation of receive Port B is the same.
12DATA TRANSFER
12.1 INITIALIZATION
inlization, the Serializer is able to transfer data to the
Deszer. he serial data stream includes a start bit and
stop binded by the serializer, which frame the sixteen
data bits. The start bit is always high and the stop bit is always
low. Tstart and stop bits also function as clock bits em-
din the serial stream.
Before the DS92UT16 sends or receives data, it must initialize
the links to and from another DS92UT16. Initialization refers
to synchronizing the Serializer’s and the Deserializer’s PLL’s
to local clocks. The local clocks must be the same frequency
or within a specified range if from different sources. After the
Serializers synchronize to the local clocks, the Deserializers
synchronize to the Serializers as the second and final in
ization step.
ThSerializer block accepts 16-bit data from the TCS As-
sembler block. The internal version of the LVDS_TxClk signal
latches the incoming data. If the LVDS_Synch input or the
TXSYNC bit of the LVC register is high for 5 LVDS_TxClk
cycles, the Serializer does not latch data from the TCS As-
sembler block.
Step 1: After applying VCC and GND to the Serializer a
serializer, the LVDS transmit outputs are held in TRI-S
and the on-chip power-sequencing circuitry diles the i
ternal circuits. When VCC reaches VCCOK 2V) in each
device, the PLL in the serializer and deserializs k-
ing to the local clock. In the Serializer, the local clock ie
LVDS_TxClk, while in the Port A Deser it is the fer-
ence clock, LVDS_ARefClk. A local scillator or
other source provides the specift to the
LVDS_TxClk and LVDS_ARefClk pins.
The Serializer transmits the data and clock bits (16+2 bits) at
18 times the LVDS_TxClk frequency. For example, if
LVDS_TxClk is 50 MHz, the serial rate is 50 X 18 =
900 Mbps. Since only 16 bits are from input data, the serial
“payload’’ rate is 16 times the LVDS_TxClk frequency. For
instance, if LVDS_TxClk = 50 MHz, the payload data rate is
50 X 16 = 800 Mbps. LVDS_TxClk is provided by the data
source and must be in the range of 30 MHz to 52 MHz.
The Serializer outputs remain -STATntil the PLL
locks to the LVDS_TxClk. Ao LVDS_TxClk, the
Serializer block is now reador synchronization
patterns. If the LVDS_Synch or the TXSYNC bit
of the LVC register is set (see S.4 LVDS CONTROL
—0x04 LVC), then the Serializer block generates and sends
the synchronization patterns (sync-pattern).
When the Port A Deserializer channel synchronizes to the in-
put from a Serializer, it drives its LVDS_ALock_n pin low, the
LLOSA bit of the ETXRXA register is cleared and valid data
is delivered to the TCS DisAssembler. The process flow is
that the Port A Deserializer locks to the embedded clock, uses
it to generate multiple internal data strobes, and then drives
the recovered clock on the LVDS_ARxClk pin. The
LVDS_ARxClk is synchronous to the data delivered to the
TCS DisAssembler. While the LVDS_ALock_n pin is low, data
to the TCS DisAssembler is valid. Otherwise, the data is in-
valid and is ignored by the TCS DisAssembler and an interrupt
may be raised on the LLOSA bit being set high.
The internal Port A Deserializer data outputs remain invalid
while the PLL locks to the reference clock.
When the Port A Deserializers PLL locks to incoming data or
sync-pattern on the LVDS_ADin pins, it will clear the corre-
sponding Local Loss Of Signal bit, LLOSA, in the ETXRXA
register (see Section 18.10 ECC TRANSMIT BUFFER AND
RECEIVE LVDS ALARMS—0x0A ETXRXA) and the lock pin
LVDS_ALock_n will go low.
LVDS_ALock_n and LVDS_ARxClk signals will drive a mini-
mum of three CMOS input gates, a 15 pF total load.
Step 2: The Deserializer PLL must synchronize to the Serial-
izer to complete the initialization. The Serializer that is gen-
erating the stream to the Deserializer must send random
(non-repetitive) data patterns or sync-patterns during this
step of the Initialization State. The Deserializer will lock onto
sync-patterns within a specified amount of time. The lock to
The Port A Deserializer input pins LVDS_ADin are high
impedance during Receiver Powerdown (LVDS_APwdn pin
low or bit RAPWDN of the LVC register set high) and power-
off (VCC = 0V).
www.national.com
22
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
12.3 RESYNCHRONIZATION
deserializer, passes to both the DisAssembler and the seri-
alizer inputs, and then is transmitted out onto the transmission
line.
Whenever the Port A Deserializer loses lock, it will automati-
cally try to resynchronize. For example, if the embedded clock
edge is not detected two times in succession, the PLL loses
lock and the LVDS_ALock_n pin and the LLOSA bit are driven
high. The Port A Deserializer then enters the operating mode
where it tries to lock to a random data stream. It looks for the
embedded clock edge, identifies it and then proceeds through
the synchronization process.
The Local Loopback connects the serial data output from the
serializer back to the serial data input of the deserializer. The
connection route includes all the functional blocks of the
DS92UT16 except for the LVDS serial output buffers and
LVDS receiver input.
The ALBC register controls the loopbacks with the LNEN,
LNSEL, LCLA and LCLB bits.
The logic state of the LVDS_ALock_n pin indicates whether
the data is valid; when it is low, the data is valid. The system
must monitor the LVDS_ALock_n pin and LLOSA bit to de-
termine whether received data is valid. The DS92UT16 facil-
itates this by allowing an interrupt to be raised on LLOSA
being set. There is a short delay in response to the PLL losing
synchronization to the incoming data stream.
12.6 LOOP TIMING OPERATION
The DS92UT16 includes a Loop Timing mode controlled by
the LT bit of the GCS register, see Section 18.3 GENERAL
CONTROL AND STATUS—0x03 GCS. On reset the LT bit is
clear so the LVDS transmit clock is sourced directly from the
LVDS_TxClk pin. Setting the LT bit will switch the transmit
clock to be sourcfrom the recovered clock of the active
receiver, as defiby e LBA bit of the LKSC register, see
Section 18.8 LITUS ND CONTROL—0x08 LKSC.
The LVDS trsmit TCblocks will then be driven by this
internal cland not thVDS_TxClk pin.
The user can choose to resynchronize to the random data
stream or to force fast synchronization by pulsing the Serial-
izer LVDS_Synch pin or setting the TXSYNC bit. This scheme
is left up to the user discretion. One recommendation is to
provide a feedback loop using the LVDS_ALock_n pin itself
to control the sync request of the Serializer, which is the
LVDS_Synch pin.
Switchitrom Loop Timing mode will cause the trans-
mitted scramblquence to change. This will cause the far
end evice to loosscrambler lock. However, it may take a
nber frames for the far end device to register the lose of
mr locbecause of the setting of the confidence
couseection 11.3 DESCRAMBLER OPERATION.
The far device will then relock to the new scrambler se-
quence and operation will resume as normal.
12.4 POWERDOWN/TRI-STATE
The Powerdown state is a very low power consuming sleep
mode that the Serializer and Deserializer will occupy while
waiting for initialization. You can also use the LVDS_ADenb,
LVDS_BDenb,
LVDS_TxPwdn,
LVDS_APwdn
and
LVDS_BPwdn pins, or the TXPWDN, TXADEN, TXBDEN,
RAPWDN and RBPWDN bits of the LVC register to reduce
power when there are no pending data transfers. The Port A
Deserializer enters Powerdown when LVDS_APwdn is d
low or the RAPWDN bit is set. In Powerdown, the PL
and the outputs go into TRI-STATE, which reduces
current to the µA range.
lso, en operating in Loop Timing mode, then a Loss of
n the active LVDS receiver, or a switch of active re-
ceiver, will also cause the transmitted scrambler sequence to
change. This again will cause the far end device to loose
scrambler lock. The far end device will then relock to the new
scrambler sequence and operation will resume as normal.
To bring the Port A Deserializer block out of thowerdow
state, the system drives LVDS_APwdn high d thAP-
WDN bit is cleared. When the Deserializer exirdn,
it automatically enters the Initialization state. The sym
must then allow time for Initialization beata transcan
begin.
Note that from the time that the near end device is switched
to or from Loop Timing mode, until the time that the far end
device registers the loss of scrambler lock, all received data
at the far end will be corrupted. This is because the scrambler
lock works on a frame-by-frame basis and each frame is 56
transport containers long. For this reason switching to or from
Loop Timing mode should not be carried out on live traffic.
The LVDS_TxPwdn driven low or tbit clear,
forces the Serializer block into low power tion where
the supply current is in the µA re Serier PLL stops
and the output goes into a Tndition.
Note that both the input LVDS_TxClk clock and active port
recovered clock must be present for the switch to complete
successfully.
To bring the Serializer block erdown state, the
system drives LVDS_TxPwds the TXPWDN bit.
When the Serializer exits Powers PLL must lock to the
LVDS_TxClk before it is ready for the Initialization state. The
system must then allow time for Initialization before data
transfer can begin.
Note also that on reset the device will operate from the
LVDS_TxClk input pin clock and therefore this clock must be
present to ensure correct operation.
13.0 Switching Receive Ports
The DS92UT16 has two independent receive sections des-
ignated Port A and Port B. Either port can receive ATM cell
traffic, but only one at a time. The LBA bit of the LKSC register,
described in Section 18.8 LINK STATUS AND CONTROL—
0x08 LKSC, controls this function.
NOTE: The associated reference clock must always be active
for a change of state on the receiver powerdowns. That is
LVDS_ARefClk for LVDS_APwdn and LVDS_BRefClk for
LVDS_BPwdn must be active to have an effect.
12.5 LOOPBACK TEST OPERATION
The ECC also has two independent receive sections. This is
controlled by the settings of the ECCA and ECCB bits of the
LKSC register. Either one or both ECC receive sections can
be active. The selected ECC receive port is independent of
the active traffic port selection. For example, you may select
Port A as active for cell traffic by clearing the LBA bit, and
select the ECC to be receiving on Port B by setting the ECCB
bit. The ECC can communicate over either link without af-
The DS92UT16 includes two Loopback modes for testing the
device functionality and the transmission line continuity. They
are the Line Loopback and the Local Loopback modes.
The Line Loopback connects the serial data input
(LVDS_ADin or LVDS_BDin) to the serial data output
(LVDS_ADout and LVDS_BDout). The input signal also
routes to the parallel data input of the TCS DisAssembler. In
the Line Loopback mode, the serial input stream goes through
23
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
fecting the active cell traffic port because the ECC does not
use any of the transport container designated for ATM cells.
The same mechanism is in place for Port B using the RB-
HECC2–RBHECC0, RBHECT2–RBHECT0, RBBIPC2– RB-
BIPC0, RBBIPT2–RBBIPT0 and RBPA registers (Sec-
tion 18.46 RECEIVE PORT B HEC COUNT—0x6E to 0x70
RBHECC2 to RBHECC0, Section 18.47 RECEIVE PORT B
HEC THRESHOLD—0x71 to 0x73 RBHECT2 to RBHECT0,
Section 18.48 RECEIVE PORT B BIP COUNT—0x74 to 0x76
RBBIPC2 to RBBIPC0, Section 18.49 RECEIVE PORT B BIP
THRESHOLD—0x77 to 0x79 RBBIPT2 to RBBIPT0 and Sec-
tion 18.50 RECEIVE PORT B PERFORMANCE ALARMS—
0x7A RBPA).
Selecting the active traffic receive port is accomplished by
simply changing the value of the LBA bit. When set high, Port
B accepts the traffic cells, and when cleared to low, Port A
accepts the traffic cells. After changing the LBA value, the
MTB will complete receiving the current cell before switching
to the new receive Port. The MTB then waits for the next Start
of Cell indication from the associated TCS DisAssembler.
This means that the MTB does not need to be flushed or reset
because of a change in the active traffic receive Port.
In addition to the HEC and BIP monitoring, live traffic loopback
cell monitoring and loopback cell counts are maintained and
may raise interrupts on detection of a loopback cell as de-
scribed in Section 15.1 ATM CELL LOOPBACK.
Switching from one port to another completes in a maximum
of 6 clock cycles. However, this switch does not start until after
receiving the end of the current cell into the MTB.
Changing the value of the LBA bit to switch ports will clear the
ABSC bit of the LKSC register. When the switch from one port
to the other is completed successfully then the hardware will
set the ABSC bit. The processor can poll this bit to determine
when the switch has been completed.
14.2 BIT ERROR COUNT MODE
In addition to live affic performance monitoring, a PRBS
based LVDS linit err count facility is available. In this
mode, no cells amitteand instead the raw scrambler
pseudo-randm sece lynomial x31 + x28 + 1) is trans-
mitted. Thescrambll lock to this sequence and then
count inl bit errors in the PRBS stream. This bit error
count is aintd in a count register. As there is no data cell
delination, the frdelineation will be lost. This is not a live
tratest.
14.0 Performance Monitoring
14.1 LIVE TRAFFIC PERFORMANCE MONITORING
Performance monitoring is carried out on live traffic in two
ways. One is using the HEC bytes associated with each cell’s
TC. The other is the BIP bytes of the F channel embedded in
the frame structure, as described in Section 6.3.7.4 BIP16.
dee will transmit this PRBS data when the TXPRBS
bit TECTL register is set (Section 18.15 TEST ER-
ROR COL—0x16 TERRCTL). When this bit is set, no
cell data is transmitted and the TCS Assembler is paused. In
additiono cells will be read from the FIB queue.
A 24-bit count of errored HEC’s received on Port A is con-
tained in the RAHECC2–RAHECC0 registers (Section 18.27
RECEIVE PORT A HEC COUNT—0x2E to 0x30 RAHECC2
to RAHECC0). When the number of received erred HEC’s
exceeds the threshold defined in the RAHECT2–RAHE
registers (Section 18.28 RECEIVE PORT A HEC THR
OLD—0x31 to 0x33 RAHECT2 to RAHECT0), an in
may be raised on the RAXHEC alarm bit in the RAPA
register (Section 18.31 RECEIVE PORT A PERFORMA
ALARMS—0x3A RAPA). The count register RECC2–RA-
HECC0 is reset on read.
ceive section of Port A can lock onto this sequence and
matain the bit error count when the RABEC bit of the RACTL
register is set (Section 18.25 RECEIVE PORT A CONTROL
—0x24 RACTL). The bit error count is maintained in the
RABEC2–RABEC0 registers (Section 18.39 RECEIVE PORT
A
BIT ERROR COUNT—0x43 to 0x45 RABEC2 to
RABEC0). This counter has no associated threshold register
and will not generate an interrupt. The counter may be polled
(read) at fixed intervals to determine a Bit Error Rate. This
counter is reset on read. The count value is only valid when
both the TXPRBS bit and the RABEC bit are set.
A 24-bit count of errored BIP bytes is similarly ntainn
the RABIPC2–RABIPC0 registers (Sect18.29 RECVE
PORT A BIP COUNT—0x34 to 0xBIPC2 to RA-
BIPC0). The associated erred BIP tained in
the RABIPT2–RABIPT0 registers (SeRECEIVE
PORT A BIP THRESHOLD—0x36 to 0x3PT2 to RA-
BIPT0) and an interrupt may n the AXBIP alarm
bit in the RAPA alarm registegister RABIPC2–
RABIPC0 is also reset on re
Port B can operate in the same fashion using the RBBEC bit
of the RBCTL register (Section 18.44 RECEIVE PORT B
CONTROL—0x64 RBCTL) and the RBBEC2–RBBEC0 reg-
isters (Section 18.58 RECEIVE PORT B BIT ERROR COUNT
—0x83 to 0x85 RBBEC2 to RBBEC0).
TABLE 14. Performance Monitoring Alarms
Performance Counter
RAHECC2–RAHECC0
(Section 18.27 RECEIVE PORT A HEC
COUNT—0x2E to 0x30 RAHECC2 to
RAHECC0)
Associated Alarm
Comments
RAXHEC—Rx Port A Excessive HEC Errors.
(Section 18.31 RECEIVE PORT A
PERFORMANCE ALARMS—0x3A RAPA)
Rx Port A 24-bit errored HEC counter.
Mission mode Up-Bridge receive
direction HEC monitoring.
RABIPC2–RABIPC0
RAXBIP—Rx Port A Excessive BIP Errors.
(Section 18.31 RECEIVE PORT A
PERFORMANCE ALARMS—0x3A RAPA)
Rx Port A 24-bit errored BIP counter.
Mission mode link error monitoring.
(Section 18.29 RECEIVE PORT A BIP
COUNT—0x34 to 0x36 RABIPC2 to
RABIPC0)
RABEC2–RABEC0
None
Rx Port A 24-bit Bit Error Counter.
Non-mission mode BER counter of
PRBS data on LVDS link.
(Section 18.39 RECEIVE PORT A BIT
ERROR COUNT—0x43 to 0x45 RABEC2 to
RABEC0)
www.national.com
24
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Performance Counter
RBHECC2–RBHECC0
(Section 18.46 RECEIVE PORT B HEC
COUNT—0x6E to 0x70 RBHECC2 to
RBHECC0)
Associated Alarm
Comments
RBXHEC—Rx Port B Excessive HEC Errors.
(Section 18.50 RECEIVE PORT B
PERFORMANCE ALARMS—0x7A RBPA)
Rx Port B 24-bit errored HEC counter.
Mission mode Up-Bridge receive
direction HEC monitoring.
RBBIPC2–RBBIPC0
RBXBIP—Rx Port B Excessive BIP Errors.
(Section 18.50 RECEIVE PORT B
PERFORMANCE ALARMS—0x7A RBPA)
Rx Port B 24-bit errored BIP counter.
Mission mode link error monitoring.
(Section 18.48 RECEIVE PORT B BIP
COUNT—0x74 to 0x76 RBBIPC2 to
RBBIPC0)
RBBEC2–RBBEC0
None
Rx Port B 24-bit Bit Error Counter.
Non-mission mode BER counter of
PRBS data on LVDS link.
(Section 18.58 RECEIVE PORT B BIT
ERROR COUNT—0x83 to 0x85 RBBEC2 to
RBBEC0)
RAU2DLBC
(Section 18.35 RECEIVE PORT A
U2DLBC—Up-2-Down Loopback Cell Count
Change. Cell(s) received on LVDS interface.
Rx Port A 8-bit Loopback cell counter.
Mission mode diagnostic aid.
UP2DOWN LOOPBACK CELL COUNT— (Section 18.72 UTOPIA AND ATM ALARM—
0x3E RAU2DLBC)
0xE1 UAA)
RBU2DLBC
(Section 18.54 RECEIVE PORT B
U2DLBC—Up-2-Down Loopback Celount
Change. Cell(s) received on LVDS rface.
RPort B 8-bit Loopback cell counter.
ission mode diagnostic aid.
UP2DOWN LOOPBACK CELL COUNT— (Section 18.72 UTOPIA AND ATALS—
0x7E RBU2DLBC)
0xE1 UAA)
D2ULBCC
D2ULBC—Down-2-Up Loock Cell Count
UTOPIA Interface 8-bit Loopback cell
(Section 18.71 ATM DOWN2UP
LOOPBACK CELL COUNT—0xE0
D2ULBCC)
Change. Cell(s) transmittacut on UTOPIA counter. Mission mode diagnostic aid.
interface. (Section 18.72 UTOANATM
ALARMS—0xE1 UAA)
TABLE 15. GeAlms
Alarms
Description
LLOSC (Section 18.10 ECC
TRANSMIT BUFFER AND
RECEIVE LVDS ALARMS—0x0A
ETXRXA)
Change of Status oLOSB.
LLOSA (Section 18.10 ECC
TRANSMIT BUFFER AND
RECEIVE LVDS ALARMS—0x0A
ETXRXA)
Loss of SigLVreceive Port A.
Loss n LVDS receive Port B.
ansmit buffer ready for new message.
Receive Port A. Link Label Change of value.
LLOSB (Section 18.10 ECC
TRANSMIT BUFFER AND
RECEIVE LVDS ALARMS—0x
ETXRXA)
ETXBR (Section 18.10 ECC
TRANSMIT BUFFER AND
RECEIVE LVDS ALARMS—0x0A
ETXRXA)
RALLC (Section 18.23 RECEIVE
PORT A LOCAL ALARMS —0x22
RALA)
RALLM (Section 18.23 RECEIVE Receive Port A. Link Label Mismatch between expected and received value.
PORT A LOCAL ALARMS —0x22
RALA)
RALCS (Section 18.23 RECEIVE Receive Port A. Change of Status on RALDSLL, RALTCLL or RALFLL.
PORT A LOCAL ALARMS —0x22
RALA)
RALDSLL (Section 18.23 RECEIVE Receive Port A. Descrambler Loss of Lock.
PORT A LOCAL ALARMS —0x22
RALA)
25
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Alarms
Description
RALTCLL (Section 18.23 RECEIVE Receive Port A. Transport Container delineation Loss of Lock.
PORT A LOCAL ALARMS —0x22
RALA)
RALFLL (Section 18.23 RECEIVE Receive Port A. Frame delineation Loss of Lock.
PORT A LOCAL ALARMS —0x22
RALA)
ERABF (Section 18.23 RECEIVE Receive Port A. ECC Receive Buffer Full—contains valid new message.
PORT A LOCAL ALARMS —0x22
RALA)
RARCS (Section 18.33 RECEIVE Receive Port A. Remote Change of Status on RARLOSA, RARLOSB, RARBA or RARDSLL.
PORT A REMOTE STATUS AND
ALARMS—0x3C RARA)
RARLOSA (Section 18.33
RECEIVE PORT A REMOTE
STATUS AND ALARMS—0x3C
RARA)
Receive Port A. Remote Loss of Signal on LVDS receive Port A.
Receive Port A. Remote Loss of Signal on LVS receiB.
RARLOSB (Section 18.33
RECEIVE PORT A REMOTE
STATUS AND ALARMS—0x3C
RARA)
RARBA (Section 18.33 RECEIVE Receive Port A. Remote Active receporB or A.
PORT A REMOTE STATUS AND
ALARMS—0x3C RARA)
RARDSLL (Section 18.33
RECEIVE PORT A REMOTE
STATUS AND ALARMS—0x3C
RARA)
Receive Port A. Remote Descrambler Loss Lock.
RBLLC (Section 18.42 RECEIVE
PORT B LOCAL ALARMS—0x62
RBLA)
Receive Port B. Linge of value.
RBLLM (Section 18.42 RECEIVE Receive PoB. Link Label Mismatch between expected and received value.
PORT B LOCAL ALARMS—0x62
RBLA)
RBLCS (Section 18.42 RECEIVE Recort B. Chge of Status on RBLDSLL, RBLTCLL or RBLFLL.
PORT B LOCAL ALARMS—0x62
RBLA)
RBLDSLL (Section 18.42 RECEIVE Receive . Descrambler Loss of Lock.
PORT B LOCAL ALARMS—0x
RBLA)
RBLTCLL (Section 18.42 RECe Port B. Transport Container delineation Loss of Lock.
PORT B LOCAL ALARMS—0x62
RBLA)
RBLFLL (Section 18.42 RECEIVE Receive Port B. Frame delineation Loss of Lock.
PORT B LOCAL ALARMS—0x62
RBLA)
ERBBF (Section 18.42 RECEIVE Receive Port B. ECC Receive Buffer Full—contains valid new message.
PORT B LOCAL ALARMS—0x62
RBLA)
RBRCS (Section 18.52 RECEIVE Receive Port B. Remote Change of Status on RBRLOSA, RBRLOSB, RBRBA or RBRDSLL.
PORT B REMOTE STATUS AND
ALARMS—0x7C RBRA)
RBRLOSA (Section 18.52
RECEIVE PORT B REMOTE
STATUS AND ALARMS—0x7C
RBRA)
Receive Port B. Remote Loss of Signal on LVDS receive Port A
www.national.com
26
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Alarms
Description
RBRLOSB (Section 18.52
RECEIVE PORT B REMOTE
STATUS AND ALARMS—0x7C
RBRA)
Receive Port B. Remote Loss of Signal on LVDS receive Port B.
RBRBA (Section 18.52 RECEIVE Receive Port B. Remote Active receive port B or A.
PORT B REMOTE STATUS AND
ALARMS—0x7C RBRA)
RBRDSLL (Section 18.52
RECEIVE PORT B REMOTE
STATUS AND ALARMS—0x7C
RBRA)
Receive Port B. Remote Descrambler Loss of Lock.
PDULA (Section 18.72 UTOPIA
AND ATM ALARMS—0xE1 UAA)
PDU Length greater than 64 bytes.
Cell Transfer error on UTOPIA interface.
Parity error detected on UTOPIA interface.
FIB buffer overflow (down-bridge).
CTFRA (Section 18.72 UTOPIA
AND ATM ALARMS—0xE1 UAA)
UPRTY (Section 18.72 UTOPIA
AND ATM ALARMS—0xE1 UAA)
FIBOVA (Section 18.72 UTOPIA
AND ATM ALARMS—0xE1 UAA)
MTBSOVA (Section 18.72 UTOPIA MTB Soft overflow. One or more of th1 MTB quehas exceeded its programmed threshold
AND ATM ALARMS—0xE1 UAA) (up-bridge).
MTBHOVA (Section 18.72 UTOPIA MTB Hard overflow. The MTB queuverfed (up-bridge).
AND ATM ALARMS—0xE1 UAA)
—0xF7 to 0xFA ALFLT3 to AFLT0. These registers define the
15.0 Loopback Operation
ell her bits that are compared with the header format de-
in the ALBCF3–ALBCF0 registers. It is therefore pos-
siblto mask out any bits of the cell header from comparison.
To assist in diagnostic testing, the DS92UT16 provides both
physical interface loopbacks and ATM cell loopback
shown in Figure 7 in Section 6.8 LOOPBACKS. The fo
suitable for designer or commission testing when the
is not passing live traffic. The latter allows cell trace t
on live traffic. All loopbacks are programmable the mic
processor interface. The LVDS physical loocks are de-
scribed in Section 12.5 LOOPBACK TEST O
For Down2Up_ATM loopback on the UTOPIA interface only,
a loopback cell will be sent back out to the MPhy address on
which it was received. So, if a loopback cell was detected
coming into the device on MPhy address 0x01, then it will be
sent back out of the device on the next occasion that a cell for
MPhy address 0x01 is to be sent.
For Up2Down_ATM loopback on the LVDS interface, the
MPhy address is embedded in the incoming PDU. Therefore,
the loopback cell is simply transmitted back out.
15.1 ATM CELL LOOPBACK
The ATM Cell Loopback function provsarate loop-
back operations. The Down2Up_ATects spe-
cial loopback cells received on the Urface and
transmits them back out over tUTOPerface. The
Up2Down_ATM loopback deal loopback cells re-
ceived on the LVDS interfaits them back out
over the LVDS interface. Fiection 6.8 LOOP-
BACKS illustrates both of thens.
For Down2Up_ATM loopback, only loopback cells as defined
by the ALBCF3–ALBCF0 and ALFLT3–ALFLT0 registers are
looped-back and all other cells are passed as normal.
For Up2Down_ATM loopback, only loopback cells as defined
by the ALBCF3–ALBCF0 and ALFLT3–ALFLT0 registers are
looped back and all other cells are passed as normal.
These loopback circuits accommodate one loopback cell at a
time. Therefore, a loopback cell should be sent and received
before transmitting another loopback cell.
The Down2Up Loopback Cell Count register, the D2ULBCC
in Section 18.71 ATM DOWN2UP LOOPBACK CELL COUNT
—0xE0 D2ULBCC, maintains a count of the Down2UP_ATM
loopback cells. Whenever this counter increments, the D2UL-
BC alarm in the UAA register is set. See Section 18.72
UTOPIA AND ATM ALARMS—0xE1 UAA. Note that this
counter only increments when the loopback cell exits the de-
vice. So the D2ULBC counter increments on outgoing loop-
back cells.
The ATM and LVDS Loopback Control register ALBC controls
the ATM cell loopback functionality. See Section 18.14 GEN-
ERAL PURPOSE INPUT OUTPUT—0x15 GPIO. Bit D2ULB
enables the Down2Up_ATM loopback and bit U2DLB en-
ables the Up2Down_ATM loopback. It is possible to enable
both loopback operations at the same time.
Both Receive Port
A and Receive Port B maintain
The special loopback cell format is defined in the ATM Loop-
back Cell Format registers ALBCF3–ALBCF0. See Sec-
tion 18.20 ATM LOOPBACK CELL FORMAT —0x1C to 0x1F
ALBCF3 to ALBCF0. These registers define the contents of
the cell’s four header bytes, which indicate that a received cell
is a loopback cell. Associated with the ALBCF3–ALBCF0 reg-
isters are the ATM Loopback Cell Filter registers ALFLT3–
ALFLT0. See Section 18.74 ATM LOOPBACK CELL FILTER
Up2Down_ATM loopback counts. The registers that maintain
these counts are the Receive Port A Up2Down Loopback Cell
Count register, RAU2DLBC, and the Receive Port B Up2-
Down Loopback Cell Count register, RBU2DLBC. See Sec-
tion 18.35 RECEIVE PORT A UP2DOWN LOOPBACK CELL
COUNT—0x3E RAU2DLBC and Section 18.54 RECEIVE
27
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
PORT B UP2DOWN LOOPBACK CELL COUNT—0x7E
RBU2DLBC.
16.0 Embedded Communication
Channel Operation
This section describes the ECC operation. The ECC transmits
one 8 byte message per frame over the link under software
control. Flow control ensures that messages are not overwrit-
ten at the receive end.
Whenever the counter in the Active receiver (as defined by
the LBA bit of the LKSC, see Section 18.8 LINK STATUS AND
CONTROL—0x08 LKSC) increments, the U2DLBC alarm in
the UAA register is set. See Section 18.72 UTOPIA AND ATM
ALARMS—0xE1 UAA. Although each counter increments
whenever it detect an incoming loopback cell, only increments
to the active receiver’s counter can set the alarm. Note that
received loopback cells increment these counters. So the
U2DLBC counter increments on incoming loopback cells.
Alarms in the UAA register will raise an interrupt if the appro-
priate interrupt enables are set in the UAIE register. See
Section 18.73 UTOPIA AND ATM INTERRUPT ENABLES—
0xE2 UAIE.
The message to be transmitted is written to the ETXD7–
EXTD0 transmit buffer registers and the received messages
are stored in the Port A ERAD7–ERAD0 or Port B ERBD7–
ERBD0 receive buffer registers. Software control is achieved
on the transmit side using the ECC Transmit Buffer Ready
(ETXBR) interrupt of the ETXRXA register and the ECC
Transmit Send (ETXSD) register.
There are independent receive sections in Port A and Port B
and these are controlled using the ECC Receive Port A Buffer
Full (ERABF) intept of the Receive Port A Local Alarm
(RALA) register, d the ECC Receive Port B Buffer Full
(ERBBF) interrf tReceive Port B Local Alarm (RBLA)
register respectivee cce of receiving ECC messages
on Port A oort B is lled by the ECCB and ECCA bits
of the Litus and Control (LKSC) register.
Loopback cells are only counted and looped-back in the ap-
propriate loopback mode. If the loopback mode is not set then
any incoming loopback cells are simply treated as normal
traffic cells and passed by the device. In Up2Down_ATM
loopback mode, only cells from the Active receiver will be
looped-back.
A loopback cell transmission may be initiated by the
DS92UT16 over the LVDS transmit link. The TXLVLB bit in
the ALBC register controls this functionality. Setting the
TXLVLB bit causes a single loopback cell to be transmitted
over the LVDS transmit link. When the DS92UT16 finishes
transmitting the loopback cell, it automatically clears the
TXLVLB bit. So, the processor, on setting the TXLVLB bit,
should poll it to detect that it clears before trying to set it again
to send another loopback cell. The loopback cell transmitted
will have a header of the format defined by the ALBCF3–AL-
BCF0 registers and an MPhy address as defined by th
ALBMP register
The Reote and Signalling Byte carries the ECC sig-
nalinbits. The smitted Remote Alarm and Signalling
Bycarries the ESS signal for both of the local ECC receive
ionESSA and ESSB. At the receiver a choice must be
mato wch ESS bit of the received Remote Alarm and
Signale is valid for the local ECC transmitter. This is
controlled y the RAESS and RBESS bits of the RACTL and
RBCTegisters respectively.
20031614
FIGURE 15. The Basic Structure Of The ECC
16.1 BASIC ECC PROTOCOL—ONE TRANSMIT AND ONE
RECEIVE
and a single receive section (Port A) of the device at the other
end of the link.
The basic operation of an ECC link is described here using
the transmit section of the device at one end of the LVDS link
The ECC transmitter and receiver communicate via the em-
bedded control signals EVN, ESSA and ESSB in the Remote
www.national.com
28
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Alarm and Signalling byte contained in the F1 byte of TC6. By
default both receive ports will extract the incoming ESSA bit
as the valid ESS to pass to the ECC transmit section. This
assumes that the local ECC transmit section is connected to
the remote device receiver port A. If the local transmitter is
connected to the remote device receiver port B then the in-
coming ESSB bit must be selected as the valid ESS to pass
to the local ECC transmit section. The selection of valid in-
coming ESS bit is accomplished using the RAESS and
RBESS bits of the RACTL and RBCTL registers respectively.
stream. If an errored HEC is detected on any of the ECC
message bytes then the receiver assumes all 8 bytes are cor-
rupted and will re-extract the entire message on the next
frame. The transmitter will continue to transmit the message
as long as the ESS signal is clear.
When the receiver determines that it has received the entire
message it sets the receive buffer full ERABF bit. This pre-
vents the receive buffer ERAD7–ERAD0 being updated by
the incoming ECC bytes so that the message cannot be over-
written. It also raises an interrupt to the local processor to
indicate that a valid ECC message has been received.
Note that only one of the incoming remote ESS bits is valid
on each link as the local transmitter cannot be connected to
both receivers on another DS92UT16 device.
The setting of the ERABF bit also sets the ESS signal back
to the transmitter indicating that it should stop transmission.
This clears the ETXSD bit which clears the EVN signal thus
indicating that transmitted ECC data is Null (not valid).
The EVN and ESS bits are interpreted as follows:
EVN - Set = Valid ECC data in F1/F2 bytes of TC13, TC20,
TC41 and TC48.
At this stage the receive buffer is full and cannot receive any
further messages. he transmit buffer ready ETXBR is still
clear meaning thao new messages can be assembled and
ETXSD is held cr so new messages can be transmitted.
This flow control s thao new messages will be trans-
mitted until curreed message is read. This situa-
tion will ren until the reived message is read by the local
proces
Clear = Null (not valid) ECC data in F1/F2 bytes of
TC13, TC20, TC41 and TC48.
ESS - Set = Stop sending ECC data as receive buffer is full.
Clear = Send ECC data as receive buffer is ready.
The protocol for transmission of an ECC message is as fol-
lows.
Reset
Reading A Mese
The transmit buffer ready ETXBR bit is set indicating that the
transmit buffer ETXD7–ETXD0 can be written to and the Tx
Buffer Freeze is clear (inactive).
Thetting of the ERABF bit in the receiver raises an interrupt
te ll processor indicating that a valid ECC message
han reced and can be read. The receive buffer reg-
isters –ERAD0 are read only. The processor may read
theses reters in any order and the reading of them has no
affect on the ERABF bit or the ESS signal.
The transmit buffer send ETXSD bit is clear indicating that no
message is being sent and therefore EVN is clear indicating
to the receiver that Null data is being transmitted.
hehe processor is finished reading the message from the
br it writes to the ERABF bit to clear it. This allows the
receiver to receive a new message. The clearing of the ER-
ABF bit clears the ESS signals indicating to the transmitter
that it can send another message.
The receive buffer full ERABF bit is clear indicating that no
message has been received and therefore ESS is clear
cating to the transmitter that it can send a message
ready.
Assembling A Message
Transmitting a New Message
As the ETXBR bit is set the processor now hread/write
access to the transmit buffer ETXD7–ETXDand as-
semble a message by writing to these registey or.
The message can be read back for checking. Writing to tse
registers does not affect the ETXBR aXSD bits the
EVN signal.
The clearing of the incoming ESS signal causes the transmit-
ter to set the transmit buffer ETXBR bit. This allows write
access to the transmit buffer ETXD7–ETXD0 for the assem-
bly of a new message. It also releases the ETXSD bit from
reset and the processor can now set this bit to send a new
message.
Transmitting A Message
At this transmitter stage, the ETXBR bit is set, the ETXSD bit
is clear, and EVN is clear. At the receiver, the ERABF bit is
clear and the ESS signal is clear. This is the same situation
as after reset and therefore, the same sequence as above can
be followed to transmit a new message.
To transmit a message the processor simphe send bit
ETXSD. This clears the ETXBnting rite access to
the transmit buffer so the mransmitted cannot
be corrupted by writes to thXD0 registers until
transmission is completed. Tthe ETXSD bit also
set the EVN signal indicating to teiver that Valid data is
being transmitted in the F1/F2 bytes of TC13, TC20, TC41
and TC48.
Note that the transmit buffer registers can be modified or
overwritten to assemble a new message for transmission, or
the existing message can be resent simply by setting the
ETXSD bit again.
Note that transmitting a message depends on the incoming
ESS signal. If ESS is clear indicating that a message can be
sent, then the processor can write to the ETXSD bit. However,
if ESS is set indicating that a message cannot be sent, then
the ETXSD bit is held in reset and cannot be written to by the
processor to initiate transmission. This provides flow control
from the receiver back to the transmitter.
SUMMARY
•
•
•
•
•
Tx - If the ETXBR bit is set, then write the message to the
ETXD7–ETXD0 registers.
Tx - Set the ETXSD bit to send the message. This clears
ETXBR.
Rx - When full message is received, the ERABF bit is set
and this raises an interrupt.
Rx - After reading the message, clear the ERABF bit to
allow new message to be received.
Receiving A Message
As the receiver ERABF bit is clear the ESS bit is clear indi-
cating that the receiver can accept a message. The receiver
monitors the incoming EVN signal to determine when valid
data is being transmitted.
Tx - The clearing of the ERABF bit sets the ETXBR bit,
which allows a new message to be assembled and
transmitted.
On detecting EVN set the receiver uses the TC number to
extract the 8 ECC message bytes from the incoming data
29
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
Flow Charts
The Flow Charts in Figures 16, 17 summarize the control of
the ECC receive and transmit.
20031
FIGURE 16. ECC Transmit Flort
20031616
FIGUE 17. ECC Receive Flow Chart (Port A)
16.2 ECC OPERATION WITND STANDBY
RECEIVERS
clear. The incoming valid ESS signal received over Link A,
“RxA valid ESS”, is the only one used by the ECC transmit
section in Tx. The RxA port is programmed to extract the in-
coming ESSA bit as the valid ESS, as the Device 1 transmitter
is connected to Device 2 receiver Port A. This is accomplished
by clearing the RAESS bit of the RACTL register.
The DS92UT16 has two independent receive sections, Port
A and Port B. These each contain an ECC receive section
and the ECC can be configured to receive over Port A or Port
B or over both Port A and Port B together. The ECC receive
port can be selected independent of the traffic receive port.
Therefore, traffic data is received on the active port designat-
ed by the LBA bit of the LKSC register but the ECC can
receive on either Port A or Port B as designated by the ECCA
and ECCB bits of the same LKSC register. In a protected
system with an active and standby LVDS link this can be used
to communicate with the standby link while traffic continues
to be received from the active link. Figure 18 shows three
DS92UT16 devices with ECC communication over both links.
In this case, when an ECC message is transmitted, the “RxA
valid ESS” signals when the message has been successfully
received by the far-end Device 2. So, ECC communications
only occur over Link A between Device 1 and Device 2.
Device 2: The ECCA bit of the LKSC register is set and the
ECCB bit is clear. The incoming valid ESS signal received
over Link A, “RxA valid ESS”, is the only one used by the ECC
transmit section in Tx. The RxA port is programmed to extract
the incoming ESSA bit as the valid ESS, as the Device 2
transmitter is connected to Device 1 receiver Port A. This is
accomplished by clearing the RAESS bit of the RACTL reg-
ister.
ECC Receive on Port A: Device 1 communicating with
Device 2 only.
Device 1: For the ECC to communicate across Link A only,
the ECCA bit of the LKSC register is set and the ECCB bit is
www.national.com
30
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
ECC Receive on Port B: Device 1 communicating with
Device 3 only.
ECC Receive on Port A and Port B: Device 1 communi-
cating with Device 2 and Device 3.
Device 1: For the ECC to communicate across Link B only,
the ECCA bit of the LKSC register is clear and the ECCB bit
is set. The incoming valid ESS signal received over Link B,
“RxB valid ESS”, is the only one used by the ECC transmit
section in Tx. The RxB port is programmed to extract the in-
coming ESSB bit as the valid ESS, as the Device 1 transmitter
is connected to Device 3 receiver Port B. This is accomplished
by setting the RBESS bit of the RBCTL register.
See Figure 18.
Device 1: For the ECC to communicate across both Link A
and Link B, the ECCB and ECCA bits of the LKSC register
are both set. The incoming valid ESS signals received over
Link A “RxA valid ESS” and Link B “RxB valid ESS” are both
used by the ECC transmit section in Tx.
In this case, when an ECC message is transmitted, both the
“RxA valid ESS” and “RxB valid ESS” signals must be used
to indicate that the message has been successfully received
by both Device 2 and Device 3 before a new message can
be transmitted. So ECC communications occur over both Link
A and Link B.
In this case, when an ECC message is transmitted, the “RxB
valid ESS” signals when the message has been successfully
received by the far-end Device 3. So, ECC communications
only occur over Link B between Device 1 and Device 3.
Device 3: The ECCA bit of the LKSC register is clear and the
ECCB bit is set. The incoming valid ESS signal received over
Link B, “RxB valid ESS”, is the only one used by the ECC
transmit section in Tx. The RxB port is programmed to extract
the incoming ESSB bit as the valid ESS, as the Device 3
transmitter is connected to Device 1 receiver Port B. This is
accomplished by setting the RBESS bit of the RBCTL regis-
ter.
Device 2 and 3: are configured as above for communicating
with only Device 1.
Note that, when Dce 1 wants to transmit a new message
it must wait until h Deice 2 and Device 3 indicate that they
have received lamessage. When Device 2 wants to
transmit a new mee it st only wait until Device 1 indi-
cates that has recethe last message. Similarly for
Device 3 mitting a new message it must only wait until
Device indithat it has received the last message
31
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
20031617
18. ECC Signalling with Active and Standby Links
register associated with that Receive Port and disallows writ-
ing to that port’s registers. Receive Port A (RxA) in Power-
down mode inhibits access to registers described inSec-
tion 18.21 RECEIVE PORT A LINK LABEL—0x20 RALL to
Section 18.39 RECEIVE PORT A BIT ERROR COUNT—
0x43 to 0x45 RABEC2 to RABEC0. Receive Port B (RxB) in
Power-down mode inhibits access to registers described in
Section 18.40 RECEIVE PORT B LINK LABEL—0x60 RBLL
to Section 18.58 RECEIVE PORT B BIT ERROR COUNT—
0x83 to 0x85 RBBEC2 to RBBEC0. The contents of these
registers are not lost or altered in Power-down mode.
17.0 Microprocessor Interface
Operation
The DS92UT16 contains a flexible microprocessor port ca-
pable of interfacing to either Intel or Motorola processors. In
addition to an 8-bit address and 8-bit data bus plus the asso-
ciated bus protocol control signals, the port includes an open-
drain interrupt signal. This signal may be asserted on the
detection of various alarms within the device and any of the
potential internal sources of this interrupt may be individually
inhibited via an interrupt mask.
Typical processor Read and Write cycles for this device are
shown in Figures 19, 20, 21, 22. The associated timing for
each cycle is given in Tables 16, 17, 18, 19.
Powering down a Receive Port inhibits access to the associ-
ated registers. This feature saves power when a Receive Port
is not in use. It allows re-reading the last value read from a
www.national.com
32
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
20031618
FIGURE 19. Intel Write Cy
TABLE 16. Intel rite
No.
1
Parameter
Min
Max
Units
ns
Address Setup Time before Chip Select Low
Chip Select Setup before Write Low
Write Pulse Width (Note 6, Note 7)
Data Setup before Write High (Note 6,
Data Hold after Write High
0
2
5
ns
3
6 cycles
4
5 cycles
5
5
ns
ns
ns
6
Chip Select Hold after Write High
Address Hold after Write High
5
0
7
8
Write Recovery Time (Note 6ote
1 cycle
33
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
20031619
FIGURE 20. Intel Read Cy
TABLE 17. Intel ad
No.
1
Parameter
Min
Max
Units
ns
Address Setup Time before Chip Select Low
Chip Select Setup before Write Low
Read Pulse Width (Note 6, Note 7)
Read Low to Data Low Impedance
Read Low to Valid Data (Note 6, Note
Read High to Data High Impedance
Chip Select Hold after Read Hig
Address Hold after Read Hig
0
0
2
ns
3
8 cycles
4
10
ns
5
7 cycles + 15 ns
15
6
ns
ns
ns
7
0
0
8
9
Read Recovery Time (Note 6, 8)
1 cycle
www.national.com
34
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
20031620
FIGURE 21. Motorola Write C
TABLE 18. MotoroWrit
No.
1
Parameter
Min
Max
Units
ns
Address Setup Time before Chip Select Low
Chip Select Setup before Data Strobe Low
Read/Write Setup before Data Strobe Low
Data Strobe Pulse Width (Note 6, Note
Data Setup before Data Strobe High 7)
Data Hold after Data Strobe High
0
2
0
ns
3
5
ns
4
6 cycles
5
5 cycles
6
5
ns
ns
ns
ns
7
Read/Write Hold after Data StroHigh
Chip Select Hold after Data Sbe Hig
Address Hold after Data Strob
5
8
5
0
9
10 Data Strobe Recovery T(Note 6, N8)
1 cycle
35
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
20031621
FIGURE 22. Motorola Read C
TABLE 19. MotoroRea
No.
1
Parameter
Min
Max
Units
ns
Address Setup Time before Chip Select Low
Chip Select Setup before Data Strobe Low
Read/Write Setup before Data Strobe Low
Data Strobe Pulse Width (Note 6, Note
Data Strobe Low to Data Low Impeda
Data Strobe Low to Valid Data (Note
Data Strobe High to Data High Ipedan
Read/Write Hold after Data Sbe Hig
Chip Select Hold after Data Sigh
0
2
0
5
ns
3
ns
4
8 cycles
5
10
ns
6
7 cycles + 15 ns
15
7
ns
ns
ns
ns
8
5
9
5
0
10 Address Hold after Data obe High
11 Data Strobe Recover6, Note 8)
1 cycle
Note 6: “Cycle” must be greater than or equal to tof the slowest DS92UT16 clock.
Note 7: When an LVDS receiver lose“lock”, ecovered clock may stay high for up to 2.5 cycles. If a processor access is in progress to one of the
registers in either of the recovered cen a READ will return the value of the last READ access, and a WRITE will not change the value of the target
register. To accommodate this posck, 3 cycles has been added to these timings and they should therefore be regarded as worst case. If access
time needs to be increased and a nough to accept these possible incorrect accesses then 3 cycles can be removed from these timings.
Note 8: A recovery time of 1 cycle is een successive processor accesses.
INTERFACE and Section 18.1 SOFTWARE LOCK—0x00 to
0x01 SLK0 to SLK1.
SOFTWARE LOCK
Note that the device has a software lock mechanism imple-
mented for security. This is described in Section 6.5 CPU
www.national.com
36
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.0 Register Description
This section describes all the software accessible registers in the DS92UT16. A summary of all registers is shown in Table 20.
TABLE 20. Register Map Summary
Software
Lock
Reset
Value
Register Name
Address
Section and Description
SLK0
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
0x10
0x11
0x12
0x13
0x14
0x15
0x16
0x17
0x18
0x19
0x1A
0x1B
0x1C
0x1D
0x1E
0x1F
0x20
0x21
0x22
0x23
0x24
0x25
0x26
0x27
0x28
0x29
0x2A
0x2B
N
N
N
Y
Y
Y
N
N
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
Y
Y
Y
N
N
N
N
N
N
Y
0x00
0x00
(Note 9)
0x05
0x3B
0x00
0x00
0x00
0x34
0x00
0x01
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
xF0
0x00
0
0x00
x00
00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x01
18.1 Software Lock 1
18.1 Software Lock 2
SLK1
VID
18.2 Version Identification
GCS
18.3 General Control and Status
18.4 LVDS Control
LVC
PDUCFG
IS
18.5 PDU Configuration
18.6 Interrupt Source
ISE
18.7 Interrupt Source Enas
18.8 Link Status and Con
LKSC
TXLL
18.9 Transmit Link Lel
ETXRXA
ETXRXIE
ETXSD
ETXD7
ETXD6
ETXD5
ETXD4
ETXD3
ETXD2
ETXD1
ETXD0
GPIO
18.10 ECC Transuffer and Receive LVDS Alarms
18.11 ECC Tranmit Band Receive LVDS Interrupt Enables
18.12 ECC Tnsmit Buffer nd
18.13 ECranst Buffer 7
18.13 ECC mit fer 6
18.13 ECC Tranuffer 5
18ECC Transmit Buffer 4
18.13 Trsmit Buffer 3
ECC ansmit Buffer 2
CC Transmit Buffer 1
CC Transmit Buffer 0
General Purpose Input/Output
18.15 Test Error Control
TERRCTL
ERRBIP1
ERRBIP0
ERRHEC
ALBC
18.16 BIP Error Mask 1
18.16 BIP Error Mask 0
18.17 HEC Error Mask 0
18.18 ATM and LVDS Loopback Control
18.19 ATM Loopback Cell MPhy
18.20 ATM Loopback Cell Format 3
18.20 ATM Loopback Cell Format 2
18.20 ATM Loopback Cell Format 1
18.20 ATM Loopback Cell Format 0
18.21 Receive Port A Link Label
18.22 Receive Port A Expected Link Label
18.23 Receive Port A Local Alarms
18.24 Receive Port A Local Interrupt Enables
18.25 Receive Port A Control
ALBMP
ALBCF3
ALBCF2
ALBCF1
ALBCF0
RALL
RAELL
RALA
RALIE
RACTL
Reserved
ERAD7
ERAD6
ERAD5
ERAD4
ERAD3
ERAD2
N
N
N
N
N
N
0x00
0x00
0x00
0x00
0x00
0x00
18.26 ECC Receive Buffer A 7
18.26 ECC Receive Buffer A 6
18.26 ECC Receive Buffer A 5
18.26 ECC Receive Buffer A 4
18.26 ECC Receive Buffer A 3
18.26 ECC Receive Buffer A 2
37
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
Software
Lock
Reset
Value
Register Name
Address
Section and Description
18.26 ECC Receive Buffer A 1
ERAD1
0x2C
0x2D
0x2E
0x2F
0x30
0x31
0x32
0x33
0x34
0x35
0x36
0x37
0x38
0x39
0x3A
0x3B
0x3C
0x3D
0x3E
0x3F
0x40
0x41
0x42
0x43
0x44
0x45
0x46
0x47
0x48
0x49 to 0x56
0x57
0x58
0x59
0x5A
0x5B
0x5C
0x5D
0x5E
0x5F
0x60
0x61
0x62
0x63
0x64
0x65
0x66
0x67
0x68
0x69
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
0x00
0x00
0x00
0x00
0x00
0xFF
0xFF
0xFF
0x00
0x00
0x00
0xFF
0xFF
0xFF
0x00
0x00
0x0D
0x00
0x00
ERAD0
18.26 ECC Receive Buffer A 0
RAHECC2
RAHECC1
RAHECC0
RAHECT2
RAHECT1
RAHECT0
RABIPC2
RABIPC1
RABIPC0
RABIPT2
RABIPT1
RABIPT0
RAPA
18.27 Receive Port A HEC Count 2
18.27 Receive Port A HEC Count 1
18.27 Receive Port A HEC Count 0
18.28 Receive Port A HEC Threshold 2
18.28 Receive Port A HEC Threshold 1
18.28 Receive Port A HEC Threshold 0
18.29 Receive Port A BIP Count 2
18.29 Receive Port A BIP Count 1
18.29 Receive Port A BIP Count 0
18.30 Receive Port A BIP Tshold 2
18.30 Receive Port A BIP hresld 1
18.30 Receive Port A BIP old
18.31 Receive Port Performalarms
18.32 Receive Prformance Interrupt Enables
18.33 Receive Port A Ree Alarms
18.34 RecePort A Remote Interrupt Enables
18.35 Ree Pt A ATM Up2Down Loopback Cell Count
RAPIE
RARA
RARIE
RAU2DLBC
Unused
RACDT
Y
Y
Y
N
N
N
0x78
0x78
0x88
0x00
0x0
0x00
18.36 Receive PoCell Delineation Thresholds
18.eceive rt A Frame Delineation Thresholds
18.38 RPort a Descrambler Lock Thresholds
Receive Port A Bit Error Count 2
RAFDT
RADSLKT
RABEC2
RABEC1
RABEC0
Unused
ceive Port A Bit Error Count 1
eceive Port A Bit Error Count 0
Reserved
Reserved
Unused
Resered
Reserved
Reserved
Reserved
Unused
Reserved
Reserved
Reserved
Reserved
RBLL
N
N
N
N
Y
0x00
0x00
0x00
0x00
0x01
18.40 Receive Port B Link Label
RBELL
18.41 Receive Port B Expected Link Label
18.42 Receive Port B Local Alarms
18.43 Receive Port B Local Interrupt Enables
18.44 Receive Port B Control
RBLA
RBLIE
RBCTL
Reserved
ERBD7
N
N
N
N
0x00
0x00
0x00
0x00
18.45 ECC Receive Buffer B 7
18.45 ECC Receive Buffer B 6
18.45 ECC Receive Buffer B 5
18.45 ECC Receive Buffer B 4
ERBD6
ERBD5
ERBD4
www.national.com
38
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Software
Lock
Reset
Value
Register Name
Address
Section and Description
18.45 ECC Receive Buffer B 3
ERBD3
0x6A
0x6B
0x6C
0x6D
0x6E
0x6F
0x70
0x71
0x72
0x73
0x74
0x75
0x76
0x77
0x78
0x79
0x7A
0x7B
0x7C
0x7D
0x7E
0x7F
0x80
0x81
0x82
0x83
0x84
0x85
0x86
0x87
0x88
0x89 to 0x96
0x97
0x98
0x99
0x9A
0x9B
0x9C
0x9D
0x9E
0x9F
0xA0
0xA1
0xA2
0xA3
0xA4
0xA5
0xA6
0xA7
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0xFF
0xFF
0xFF
0x00
0x00
0x00
0xFF
0xFF
0xFF
0x00
0x00
0x0D
0x00
0x00
ERBD2
18.45 ECC Receive Buffer B 2
ERBD1
18.45 ECC Receive Buffer B 1
ERBD0
18.45 ECC Receive Buffer B 0
RBHECC2
RBHECC1
RBHECC0
RBHECT2
RBHECT1
RBHECT0
RBBIPC2
RBBIPC1
RBBIPC0
RBBIPT2
RBBIPT1
RBBIPT0
RBPA
18.46 Receive Port B HEC Count 2
18.46 Receive Port B HEC Count 1
18.46 Receive Port B HEC Count 0
18.47 Receive Port B HEC Threshold 2
18.47 Receive Port B HEC Threshold 1
18.47 Receive Port B HEC Threshold 0
18.48 Receive Port B BIP Count 2
18.48 Receive Port B BIP Cnt 1
18.48 Receive Port B BIP ount
18.49 Receive Port B BIP old
18.49 Receive Port BIP Thre1
18.49 Receive PP Threshold 0
18.50 Receive Port B Pemance Alarms
18.51 RecePort B Performance Interrupt Enables
18.52 Ree PB Remote Alarms
18.53 Receivrt B emote Interrupt Enables
18.54 Receive PorATM Up2Down Loopback Cell Count
RBPIE
RBRA
RBRIE
RBU2DLBC
Unused
RBCDT
Y
Y
Y
N
N
N
0x78
0x78
0x8
0x00
0x00
0x
18.55 Rort B Cell Delineation Thresholds
Receive Port B Frame Delineation Thresholds
ceive Port B Descrambler Lock Thresholds
eceive Port Bit Error Count 2
RBFDT
RBDSLKT
RBBEC2
RBBEC1
RBBEC0
Unused
8 Receive Port Bit Error Count 1
18.58 Receive Port Bit Error Count 0
Reserved
Reserved
Unused
Reserved
Reserved
Reserved
Reserved
Unused
Reserved
Reserved
Reserved
Reserved
UCFG
Y
Y
Y
Y
Y
0x00
0x7F
0xFF
0xFF
0xFF
18.59 UTOPIA Configuration
UCPL3
18.60 UTPOIA Connected Port List 3
18.60 UTPOIA Connected Port List 2
18.60 UTPOIA Connected Port List 1
18.60 UTPOIA Connected Port List 0
UCPL2
UCPL1
UCPL0
Reserved
UCSPL
Y
Y
0x01
0x00
18.61 UTOPIA Connected Sub-Port List
18.62 UTOPIA Sub-Port Address Location
USPAL
39
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
Software
Lock
Reset
Value
Register Name
Address
Section and Description
18.63 UTOPIA Sub-Port Address Mask
USPAM
0xA8
0xA9
0xAA
0xAB
0xAC
0xAD
0xAE
0xAF
0xB0
0xB1
0xB2
0xB3
0xB4
0xB5
0xB6
0xB7
0xB8
0xB9
0xBA
0xBB
0xBC
0xBD
0xBE
0xBF
0xC0
0xC1
0xC2
0xC3
0xC4
0xC5
0xC6
0xC7
0xC8
0xC9
0xCA
0xCB
0xCC
0xCD
0xCE
0xCF
0xD0
0xD1
0xD2
0xD3
0xD4
0xD5
0xD6
0xD7
0xD8
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
N
N
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
0x07
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x04
0x0
0x04
x04
0x
x04
0x04
04
04
0x00
0x00
0x00
0x00
0x7F
0xFF
0xFF
0xFF
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
MTBQT30
MTBQT29
MTBQT28
MTBQT27
MTBQT26
MTBQT25
MTBQT24
MTBQT23
MTBQT22
MTBQT21
MTBQT20
MTBQT19
MTBQT18
MTBQT17
MTBQT16
MTBQT15
MTBQT14
MTBQT13
MTBQT12
MTBQT11
MTBQT10
MTBQT9
MTBQT8
MTBQT7
MTBQT6
MTBQT5
MTBQT4
MTBQT3
MTBQT2
MTBQT1
MTBQT0
MTBQFL3
MTBQFL2
MTBQFL1
MTBQFL0
MTBQE3
MTBQE2
MTBQE1
MTBQE0
MTBQF3
MTBQF2
MTBQF1
MTBQF0
MTBCF3
MTBCF2
MTBCF1
MTBCF0
QFL
18.64 MTB Queue Threshold 30
18.64 MTB Queue Threshold 29
18.64 MTB Queue Threshold 28
18.64 MTB Queue Threshold 27
18.64 MTB Queue Threshold 26
18.64 MTB Queue Threshold 25
18.64 MTB Queue Threshold 24
18.64 MTB Queue Threshold 23
18.64 MTB Queue Threshold 22
18.64 MTB Queue Threshold 21
18.64 MTB Queue Thresho20
18.64 MTB Queue Thresd 19
18.64 MTB Queue Thresh
18.64 MTB Queue eshold 1
18.64 MTB Queushold 16
18.64 MTB Queue Thres15
18.64 MTB eue Threshold 14
18.64 MTueThreshold 13
18.64 MTB QTshold 12
18.64 MTB Queue reshold 11
18.TB Quee Threshold 10
18.64 Mue Threshold 9
MTB Queue Threshold 8
TB Queue Threshold 7
TB Queue Threshold 6
4 MTB Queue Threshold 5
18.64 MTB Queue Threshold 4
18.64 MTB Queue Threshold 3
18.64 MTB Queue Threshold 2
18.64 MTB Queue Threshold 1
18.64 MTB Queue Threshold 0
18.65 MTB Queue Full 3
18.65 MTB Queue Full 2
18.65 MTB Queue Full 1
18.65 MTB Queue Full 0
18.66 MTB Queue Empty 3
18.66 MTB Queue Empty 2
18.66 MTB Queue Empty 1
18.66 MTB Queue Empty 0
18.67 MTB Queue Flush 3
18.67 MTB Queue Flush 2
18.67 MTB Queue Flush 1
18.67 MTB Queue Flush 0
18.68 MTB Cell Flush 3
18.68 MTB Cell Flush 2
18.68 MTB Cell Flush 1
18.68 MTB Cell Flush 0
18.69 Queue Flush
www.national.com
40
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Software
Lock
Reset
Value
Register Name
Address
Section and Description
18.70 MTB Queue Overflow 3
MTBQOV3
MTBQOV2
MTBQOV1
MTBQOV0
Unused
0xD9
0xDA
0xDB
0xDC
N
N
N
N
0x00
0x00
0x00
0x00
18.70 MTB Queue Overflow 2
18.70 MTB Queue Overflow 1
18.70 MTB Queue Overflow 0
0xDD to
0xDF
D2ULBCC
UAA
0xE0
0xE1
0xE2
N
N
N
0x00
0x00
0x00
18.71 ATM Down2Up Loopback Cell Count
18.72 UTOPIA and ATM Alarms
UAIE
18.73 UTOPIA and ATM Interrupt Enables
Unused
0xE3 to
0xF6
ALFLT3
ALFLT2
ALFLT1
ALFLT0
Unused
0xF7
0xF8
0xF9
0xFA
0xFB
0xFC
0xFD
0xFE
0xFF
N
N
N
N
0xFF
0xFF
0xFF
0xFF
18.74 ATM Loopback Cell Fer 3
18.74 ATM Loopback Cellter
18.74 ATM Loopback Ce1
18.74 ATM Loopbacell Filt
Reserved
Reserved
Reserved
Reserved
Note 9: The reset value of the VID register will be different for various versionof the device.
Note 10: All configuration and control registers can be read by the processor ermine thtatus of the DS92UT16.
Note 11: All reserved (register bits for internal use only) and unused (no register) ll ead as zero and should be written as zero to ensure future
compatibility.
Note 12: Writing to read only register bits has no affect.
18.1 SOFTWARE LOCK—0x00 to 0x01 SLK0 to SL
TABLE SLK0–SLK1
7
0
0
6
0
0
4
0
0
3
0
0
2
0
0
1
0
0
0
0
0
SLK0 0x00
SLK1 0x01
Type: Read as 0x00
Software Lock: No
Reset Value: 0x00
The Software Lock registers mplement a software lock mechanism on configuration and control registers to prevent
spurious software changes to thce which may affect its operation. On reset the Software Lock is ON. Writes to registers
protected by this lock will have no affect. To switch the lock OFF the following sequence of writes to the SLK registers must occur.
UNLOCK SEQUENCE
1. Write data 0x00 to SLK0.
2. Write data 0xFF to SLK1.
The software lock is now OFF and those registers protected by it can be successfully written to.
To switch the lock back On the following sequence of writes to the SLK registers must occur.
41
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
LOCK SEQUENCE
1. Write data 0xDE to SLK0.
2. Write data 0xAD to SLK1.
The software lock is now ON and those registers protected by it cannot be written to.
The order of the writes in each sequence must be followed. However, the sequence does not have to be contiguous. For instance,
the processor can Write data 0xDE to SLK0, then carry out further read/write cycles to this or another device before completing
the LOCK sequence with Write data 0xAD to SLK1.
The full lock or unlock sequence must be completed to take effect.
The status of the Software Lock can be read at any time from the SLOCK bit of the GCS register.
18.2 VERSION IDENTIFICATION—0x02 VID
TABLE 22. VID
7
6
5
4
3
2
1
0
VID[7]
VID[6]
VID[5]
VID[4]
VID[3]
V
VID[1]
VID[0]
Type: Read only
Software Lock: No
Reset Value: (Note 9)
•
VID[7:0] Version identification number. NOTE that this is only a pietaVersion number and that the standard Device ID
register is contained in the JTAG TAP controller as described in Se9.0 st Features.
18.3 GENERAL CONTROL AND STATUS—0x03 GCS
TABLE 23S
7
6
5
3
2
1
0
Reserved
Reserved
GIE
RESET
CTI
TIS
SLOCK
Type:
:2] Read/Write
Bit[1:0] Read Only
Yes
Software Lock:
Reset Value:
0x05
•
•
GIE The Global Interrupt Enable vice interrupt output pin CPU_INT. Set = Interrupts enabled and Clear =
Interrupts disabled.
LT The Loop Timing bit enables the con of the Active Rx port recovered clock to the LVDS Transmit clock (the active
Rx port is as defined by the f the LSC register). LT Set = LVDS Tx clock sourced from Active Rx port recovered clock.
LT Clear = LVDS Tx clocm LVDS_TxClk pin.
•
•
RESET Set = Software rers except this bit. The Software Lock status as refiected by SLOCK is also not affected
by a software reset.
CTI Configuration Traffic Inhibihe setting of this bit initiates the Traffic Inhibit functionality, which stops traffic flow. The
UTOPIA interface will stop transmitting and receiving cells, the LVDS transmit section will transmit Idle cells and the incoming
cells on the active LVDS receive port will be discarded. The MTB and FIB queues must also be flushed. This bit should be set
by the processor whenever the device is being fundamentally reconfigured from the default settings, specifically whenever any
of the PDUCFG, UCFG, USPAL or USPAM registers are being changed. The processor should set this bit before changing any
of the above mentioned register settings. This will initiate Traffic Inhibit. The TIS bit should then be polled until set to confirm
that traffic is inhibited. Note that the MTB and FIB queues MUST be flushed at this stage. This is accomplished with the
FIBFL and MTBFL bits of the QFL register described in Section 18.69 QUEUE FLUSH—0xD8 QFL. The device can now
be safely reconfigured. When the TIS bit is set, then traffic is inhibited and the device can safely be reconfigured. When
configuration is completed, then the CTI bit can be cleared by the processor and normal operation resumed. Note that CTI is
set on reset so the device is in Traffic Inhibit mode. See Section 10.0 Configuration and Traffic Inhibit Operation.
•
•
TIS Traffic Inhibit Status. This bit reflects the status of the Traffic Inhibit functionality. When set then traffic is inhibited as
described for the CTI bit above. When clear then the device operates normally. The setting of the CTI bit will initiate Traffic
Inhibit which sets the TIS bit. Clearing of the CTI bit clears the TIS bit.
SLOCK This refiects the status of the Software Lock functionality. Set = Software lock ON and Clear = Software Lock OFF.
The processor can use this bit to determine the Software Lock functionality status when writing to lockable registers.
www.national.com
42
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.4 LVDS CONTROL—0x04 LVC
TABLE 24. LVC
7
6
5
4
3
2
1
0
Reserved
Reserved
TXPWDN
TXBDEN
TXADEN
TXSYNC
RAPWDN
RBPWDN
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x3B
The LVDS control register configures the LVDS serializer/deserializers.
•
•
•
•
•
•
TXPWDN Transmit section LVDS power down. Set = Power Up and Clear = Power Down. This register value is combined with
the LVDS_TxPwdn pin to generate the internal power down setting for transmit section. If either this register bit or the
LVDS_TxPwdn pin is clear then the transmit LVDS section is powered down.
TBDEN LVDS B Transmit data output enable. Set = Enable and Clear = Disable. This register value is combined with the
LVDS_BDenb pin to generate the output enable for the LVDS transmit section B. If her this register bit or the LVDS_BDenb
pin is clear then the transmitter B output is disabled.
TXADEN LVDS A Transmit data output enable. Set = Enable and Clear = Disableegistvalue is combined with the
LVDS_ADenb pin to generate the output enable for the LVDS transmit sectio. If eithegister bit or the LVDS_ADenb
pin is clear then the transmitter A output is disabled.
TXSYNC Transmit LVDS synchronization pattern. Set = Enable and Cleble. This register value is combined with the
LVDS_Synch pin to generate the SYNCH input to the LVDS transmit section. If r this register bit or the LVDS_Synch pin
is set then SYNCH patterns are output from the LVDS transmit secti
RAPWDN Receive Port A LVDS power down. Set = Power Up anlear Power Down. This register value is combined with
the LVDS_APwdn pin to generate the internal power down setting foe Por. If either this register bit or the LVDS_APwdn
pin is clear then the receive Port A LVDS section is powered down.
RBPWDN Receive Port B LVDS power down. Set = Power Up and Clear ower Down. This register value is combined with
the LVDS_BPwdn pin to generate the internal power down sg for receive Port B. If either this register bit or the LVDS_BPwdn
pin is clear then the receive Port B LVDS section is powered .
18.5 PDU CONFIGURATION—0x05 PDUCFG
DUCFG
7
6
5
4
3
2
1
0
Reserved
UP[2]
UP[
0]
UDF
UA[2]
UA[1]
UA[0]
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x00
The PDU Configuration register es the ents and size of the PDU cells. The register does this by defining the size of the
User Prepend, whether or noto be transported, and the size of the User Append. The total size of the PDU must be
in the range 52 to 64 bytes. total size of the User Prepend, plus UDF and User Append must not exceed 12 bytes.
Further, as the DS92UT16 on internal 16 bit data path the size of the User Prepend and User Append is defined in
words (16 bits/2 bytes). If the e transported, then in UTOPIA 16-bit mode UDF1 and UDF2 bytes are transported and
in UTOPIA 8-bit mode the UDF byte is transported.
•
•
•
UP[2:0] The UP bits define the length of the User Prepend. Range 0 to 6 words.
UDF The UDF bit when set indicates that the UDF word should be transported. When cleared the UDF word is not transported.
UA[2:0] The UA bits define the length of the User Append. Range 0 to 6 words.
43
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.6 INTERRUPT SOURCE—0x06 IS
TABLE 26. IS
7
6
5
4
3
2
1
0
UAA
ETXRXA
RBLA
RBPA
RBRA
RALA
RAPA
RARA
Type:
Read only/Clear on Read
Software Lock:
Reset Value:
No
0x00
The Interrupt Source register reflects the source of pending interrupts.
•
•
•
•
•
•
•
•
UAA Set = Interrupt pending in the UAA register.
ETXRXA Set = Interrupt pending in the ETXRXA register.
RBLA Set = Interrupt pending in the RBLA register.
RBPA Set = Interrupt pending in the RBPA register.
RBRA Set = Interrupt pending in the RBRA register.
RALA Set = Interrupt pending in the RALA register.
RAPA Set = Interrupt pending in the RAPA register.
RARA Set = Interrupt pending in the RARA register.
18.7 INTERRUPT SOURCE ENABLES—0x07 ISE
TABLE 27. IS
7
6
5
4
2
1
0
UAAIE
ETXRXAIE
RBLAIE
RBPAIE
RBRAIE
RALAIE
RAPAIE
RARAIE
Type:
Software Lock:
Reset Value:
Read/Write
No
0x00
This register contains the interrupt enables for the coarms in the IS register. Set = interrupt sources enabled and
Clear = interrupt sources disabled.
18.8 LINK STATUS AND CONTROL—0x08 SC
BLE 28. LKSC
7
6
4
3
2
1
0
RDSLKOV
SCDIS
ECCA
ECCB
ABSC
LBA
FTXSCR
Type:
Bits[7:3] Read/Write
Bit[2] Read Only
Bits[1:0] Read/Write
Yes
Software Lock:
Reset Value:
0x34
The Link Status and Control register is the general control for the transmit and receive links.
•
RDSLOV Remote Descrambler Lock Override. When clear, this allows the transmitter/assembler to automatically send Idle
cells containing the Scrambler sequence whenever the remote descrambler falls out of lock. This determined by either the
RARDSLK bit or the RBRDSLK bit clear, depending on the Active receive port defined by the LBA bit. This action should force
the remote descrambler back into lock. Traffic cells are not transmitted during this action until remote descrambler lock is
achieved. If the RDSLKOV bit is set then the actual status of the remote descrambler (RARDSLK or RBRDSLK) is ignored and
it is assumed that the remote descrambler is locked and therefore normal traffic cells are transmitted.
•
•
•
SCDIS Transmit scrambler disable. When set the scrambler is disabled and unscrambled data is transmitted. When clear the
scrambler is active and transmitted data is scrambled.
CEN Coset enable. When set then the optional coset x6 + x4 + x2 + 1 is added to the generated CRC-8 used for the HEC. When
clear the coset is not added to the HEC.
ECCA ECC active on Port A bit. When set, this indicates to the ECC transmit section that the ETXBR bit (Section 18.10 ECC
TRANSMIT BUFFER AND RECEIVE LVDS ALARMS—0x0A ETXRXA) will be set only when the far end ECC receiver
connected to Port A indicates via the ECC signalling (received ESSA or ESSB signal, as selected by bit RAESS of register
www.national.com
44
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
RACTL) over Port A that the message has been received successfully. When clear the ECC signalling over Port A will be ignored
as the ECC Port A receiver is disabled and the ERABF bit will be held clear. See Section 16.0 Embedded Communication
Channel Operation.
•
ECCB ECC active on Port B bit. When set, this indicates to the ECC transmit section that the ETXBR bit (Section 18.10 ECC
TRANSMIT BUFFER AND RECEIVE LVDS ALARMS—0x0A ETXRXA) will be set only when the far end ECC receiver
connected to Port B indicates via the ECC signalling (received ESSA or ESSB signal, as selected by bit RBESS of register
RBCTL) over Port B that the message has been received successfully. When clear the ECC signalling over Port B will be ignored
as the ECC Port B receiver is disabled and the ERBBF bit will be held clear. See Section 16.0 Embedded Communication
Channel Operation.
•
•
•
ECCB and ECCA Note that when both these bits are clear, then the ECC transmitter and both receivers are inactive. The
ETXBR, ETXSD, ERABF and ERBBF bits will be held clear, the ECC signalling is ignored and no messages are transmitted or
received. See Section 16.0 Embedded Communication Channel Operation.
ECCB and ECCA Note that when both these bits are set, this indicates to the ECC transmit section that the ETXBR bit will only
be set when both far end ECC receivers indicate that the transmitted message has been received successfully (received ESS
signals). See Section 16.0 Embedded Communication Channel Operation.
ABSC A/B Switch completed. When switching active traffic receive port this bit can be polled by the processor to determine
when the switch has been completed successfully. A change of the LBA bit will clear this bit. The ABSC bit should then be
polled by the processor. The ABSC bit is set by the hardware when the active port itching is completed. This bit relates to
the LBA active traffic switching bit and is not related to the ECC port switching bit EA aECCB. See Section 13.0 Switching
Receive Ports.
•
•
LBA Local receive port A or B control. When this bit is set, then Receive Poris ActiPort A is Standby. When clear,
then Port A is Active and Port B is Standby. This bit defines the active traffort and doenot affect which ECC channel is
active as defined by the ECCA and ECCB bits above. See Section 13.0 itReceive Ports.
FTXSCR Force Transmit Scrambler Sequence. When set this forces the transmissf the scrambler sequence which is used
to lock the descrambler.
18.9 TRANSMIT LINK LABEL—0x09 TXLL
TABLE 29. TXLL
7
6
5
4
3
2
1
0
TXLL[7]
TXLL[6]
TXLL[5]
TX
TX]
TXLL[2]
TXLL[1]
TXLL[0]
Type:
Software Lock:
Reset Value:
Read/Write
No
0x00
The Transmit Link Label register defines the oe Link Trace Label byte transmitted in TC6.
TXLL[7:0] Transmitted Link Trace Labyte conte.
•
18.10 ECC TRANSMIT BUFFER AVDS ALARMS—0x0A ETXRXA
TABLE 30. ETXRXA
7
5
4
3
2
1
0
Reserved
Re
served
Reserved
LLOSC
LLOSA
LLOSB
ETXBR
Type:
Bits[3:1] Read only/Clear on Read
Bit[0] Read only
Software Lock:
Reset Value:
No
0x01
This register contains the status of the ECC transmit buffer and the LOCK signals from the two LVDS receive ports. When set the
LLOSA, LLOSB and LLOSC bits will raise an interrupt if the corresponding interrupt enable bit is set.
•
•
•
LLOSA Local Loss Of Signal on receive Port A. When set this will also clear all the bits in the Receive Port A Remote Alarms
register.
LLOSB Local Loss Of Signal on receive Port B. When set this will also clear all the bits in the Receive Port B Remote Alarms
register.
LLOSC Local Loss Of Signal Change. When set this indicates that there has been a change of value for either LLOSA or
LLOSB.
45
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
The ETXBR register bit indicates that the ECC transmit section has successfully transmitted the full ECC message consisting of
the 8 data bytes contained in registers ETXD7–ETXD0 and a new message can be assembled and transmitted. This is a read only
bit that the processor must examine before assembling a new ECC message in the ETXD7–ETXD0 data registers.
If this bit is not set then any writes to ETXD7–ETXD0 will have no affect.
On reset the ETXBR will be set indicating a message can be assembled for transmission. The processor assembles a message
in the ETXD7–ETXD0 data registers. To send the message the processor simply sets the ETXSD register bit. This clears the
ETXBR bit which prevents write access to the ETXD7–ETXD0 registers so that the message cannot be overwritten. When the far
end ECC receiver indicates via the ECC signalling that the message has been received successfully, then the near end ECC
transmitter ETXSD bit is cleared and the ETXBR bit is set. The ETXBR bit, when set, may raise a processor interrupt if the
corresponding interrupt enable is set. The processor can therefore detect that a message has been successfully transmitted either
by the interrupt or by polling the ETXBR bit.
Note that the ETXBR bit cannot be cleared on a read of this register but can only be cleared by setting the ETXSD bit of the ETXSD
register.
•
ETXBR The ETXBR bit, when set, indicates that the current ECC message has been successfully transmitted and a new
message can be assembled. If this bit is not set, then the current message has not been received at the far end and a new
message cannot be assembled. The ETXBR bit is cleared by the setting of the ETXD bit. The ETXBR bit is set either by the
far end successfully receiving a message or by the processor clearing the ETXSt.
18.11 ECC Tx BUFFER AND Rx LVDS INTERRUPT ENABLES—0x0B ETXR
TABLE 31. ETXRXIE
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
LLCIE
LLOSAIE
LLOSBIE
ETXBRIE
Type:
Software Lock:
Reset Value:
Write
No
x00
This register contains the interrupt enables for the alarmETXregister. Set = interrupt enabled and Clear = interrupt
disabled.
18.12 ECC TRANSMIT BUFFER SEND—0x0C ETXS
TABLE 32. ETXSD
7
6
5
3
2
1
0
Reserved
Reserved
ved
Rerved
Reserved
Reserved
Reserved
ETXSD
Type:
Software Lock:
Reset Value:
Read/Write
No
0x00
The ETXSD register bit conmission of an ECC message.
•
ETXSD The setting of the initiates the transmission of the ECC message in the ETXD0–ETXD7 data registers, but
only if the ETXBR is also set. Once transmission of a message has been initiated in this way, it will proceed until the far end
ECC receiver indicates, via the ECC signalling, that the message has been received successfully. The ETXSD bit will be cleared
and the ETXBR register bit is set automatically when the far end ECC receiver indicates that the message has been received
successfully. To re-send the same message simply set the ETXSD bit again.
•
•
See Section 16.0 Embedded Communication Channel Operation for a complete description of the Embedded Communication
Channel operation.
The processor can halt transmission of a message by clearing the ETXSD bit which sets the ETXBR bit to enable a new message
to be constructed in the ETXD7–ETXD0 registers.
18.13 ECC TRANSMIT BUFFER—0x0D to 0x14 ETXD7 to ETXD0
TABLE 33. ETXD7–ETXD0
7
6
5
4
3
2
1
0
ETXD7 0x0D
ETXD6 0x0E
ETXD7[7]
ETXD6[7]
ETXD7[6]
ETXD6[6]
ETXD7[5]
ETXD6[5]
ETXD7[4]
ETXD6[4]
ETXD7[3]
ETXD6[3]
ETXD7[2]
ETXD6[2]
ETXD7[1]
ETXD6[1]
ETXD7[0]
ETXD6[0]
www.national.com
46
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
7
6
5
4
3
2
1
0
ETXD5 0x0F
ETXD4 0x10
ETXD3 0x11
ETXD2 0x12
ETXD1 0x13
ETXD0 0x14
ETXD5[7]
ETXD4[7]
ETXD3[7]
ETXD2[7]
ETXD1[7]
ETXD0[7]
ETXD5[6]
ETXD4[6]
ETXD3[6]
ETXD2[6]
ETXD1[6]
ETXD0[6]
ETXD5[5]
ETXD4[5]
ETXD3[5]
ETXD2[5]
ETXD1[5]
ETXD0[5]
ETXD5[4]
ETXD4[4]
ETXD3[4]
ETXD2[4]
ETXD1[4]
ETXD0[4]
ETXD5[3]
ETXD4[3]
ETXD3[3]
ETXD2[3]
ETXD1[3]
ETXD0[3]
ETXD5[2]
ETXD4[2]
ETXD3[2]
ETXD2[2]
ETXD1[2]
ETXD0[2]
ETXD5[1]
ETXD4[1]
ETXD3[1]
ETXD2[1]
ETXD1[1]
ETXD0[1]
ETXD5[0]
ETXD4[0]
ETXD3[0]
ETXD2[0]
ETXD1[0]
ETXD0[0]
Type:
Software Lock:
Reset Value:
Read/Write
No
0x00
The ETXD7, ETXD6, ETXD5, ETXD4, ETXD3, ETXD2, ETXD1 and ETXD0 registers contain the ECC message to be transmitted.
•
ETXD7–ETXD0 When the ETXBR bit is set, then these registers have full read/write access to allow flexible assembly of the
ECC message before initiating transmission by setting the ETXSD bit. When the ETR is clear during message transmission,
these registers are read only so that the message being transmitted cannot be ovwritteand corrupted.
18.14 GENERAL PURPOSE INPUT OUTPUT—0x15 GPIO
TABLE 34. GPIO
7
6
5
4
3
2
1
0
DDR[3]
DDR[2]
DDR[1]
DDR[0]
I]
IO[2]
IO[1]
IO[0]
Type:
Bits [7:4] Read/Write
Bits[3:0] are Read Only when GPIO[3:0] are defined as Inpu, and Read/Write when GPIO[3:0] are defined as
Outputs.
Software Lock: No
Reset Value:
0xF0
The General Purpose Input/Output register controls tpurpose input/output pins GPIO[3:0].
•
•
DDR[3:0] The Data Direction bits DDR[3:0] define thf the GPIO[3:0] pins. When a DDR bit is set the corresponding
GPIO pin is an input and when the DDR bit clear the cesponding GPIO pin is an output.
IO[3:0] The IO bits reflect the value of the IO pWhen defined as an output by the DDR bit, then the IO bit value is driven
out on the corresponding GPIO pin. When as input by the DDR bit, then the IO bit value captures the incoming value
on the corresponding GPIO pin.
18.15 TEST ERROR CONTROL—0
TABLE 35. TERRCTL
7
5
4
3
2
1
0
EBRST[3]
EB
RST[1]
EBRST[0]
ERFHEC
ERCHEC
ERBIP
TXPRBS
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x00
The Test Error Control register is used to control the transmission of a PRBS pattern for Bit Error Rate testing, or to introduce HEC
and BIP errors so that the Cell Delineation, Frame Delineation, Descrambler Lock and performance monitoring functions can be
tested. This is a test register and should not be used on live traffic. The exact nature of the errored HEC and BIP bytes is determined
by the ERRBIP1, ERRBIP0 and ERRHEC registers.
•
•
•
•
EBRST[3:0] The Error Burst bits EBRST[3:0] define the number of consecutive erred HEC’s and/or BIP’s to be generated and
transmitted.
ERFHEC The Error Frame HEC bit, when set, will cause EBRST consecutive Frame HEC’s to be erred. When this has been
completed the hardware will clear this bit.
ERCHEC The Error Cell HEC bit, when set, will cause EBRST consecutive Cell HEC’s to be erred. When this has been
completed the hardware will clear this bit.
ERBIP The Error BIP bit, when set, will cause EBRST consecutive BIP’s to be erred. When this has been completed the
hardware will clear this bit.
47
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
•
TXPRBS Transmit PRBS pattern. When set, the transmit section sends the raw scrambler pseudo-random sequence
(polynomial x31 + x28 + 1). No data is transmitted. The TCS Assembler will be paused and no cells will be read from the FIB
queue. The far end receiver can lock to this PRBS pattern to count bit errors if the RABEC/RBBEC bit is set in the RACTL/
RBCTL register. This is not a live traffic test.
18.16 ERROR BIP MASK—0x17 to 0x18 ERRBIP1 to ERRBIP0
TABLE 36. ERRBIP1–ERRBIP0
7
6
5
4
3
2
1
0
ERRBIP1 0x17
ERRBIP0 0x18
EBIP1[7]
EBIP0[7]
EBIP1[6]
EBIP0[6]
EBIP1[5]
EBIP0[5]
EBIP1[4]
EBIP0[4]
EBIP1[3]
EBIP0[3]
EBIP1[2]
EBIP0[2]
EBIP1[1]
EBIP0[1]
EBIP1[0]
EBIP0[0]
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x00
The Error BIP Mask registers controls how errors are introduced into the BIP bytes en bERBIP of the TERRCTL register is
set. If a bit is set in the ERRBIP1 or ERRBIP0 register then the corresponding bit e ansmted BIP is inverted. ERRBIP1
corresponds to the first transmitted BIP byte and ERRBIP0 corresponds to the sond tmitBIP byte.
18.17 ERROR HEC MASK—0x19 ERRHEC
TABLE 37. ERRH
7
6
5
4
2
1
0
EHEC[7]
EHEC[6]
EHEC[5]
EHEC[4]
EHEC
EC[2]
EHEC[1]
EHEC[0]
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x00
The Error HEC Mask register controls the introduction the HEC byte when the ERFHEC and/or ERCHEC bits of the
TERRCTL register are set. If a bit is set in the ERRHEen the corresponding bit in the transmitted HEC is inverted.
18.18 ATM AND LVDS LOOPBACK CONTR—0x1A ALBC
TBLE 38. ALBC
7
6
4
3
2
1
0
Reserved
LNEN
LCLA
LCLB
TXLVLB
D2ULB
D2DLB
Type:
Software Lock:
Reset Value:
Read/Write
No
0x00
The ATM and LVDS Loopback egister controls the loopback functions of the device.
Note that the LVDS Line and Local Loopbacks should not be on at the same time.
•
LNEN LVDS Line Loopback enable. Set = ON and Clear = OFF. When set this enables the loopback of the LVDS receive
section, determined by LNSEL, to the transmitter.
•
•
•
•
LNSEL LVDS Line Loopback receive section select. Set = Receive B and Clear = Receive A.
LCLA LVDS Local Loopback transmit to receive Port A. Set = ON and Clear = OFF.
LCLB LVDS Local Loopback transmit to receive Port B. Set = ON and Clear = OFF.
TXLVLB When set, this initiates the transmission of a single loopback cell Down Bridge on the LVDS transmitter. This cell will
be transmitted with the MPhy address defined in the ALBMP register and will have a header format as defined in the ALBCF3–
ALBCF0 registers. When the bit is clear, the cell has been transmitted. The processor sets the bit to initiate the transmission
and then polls this bit to determine when transmission has been completed, at which time the process can be repeated to
transmit another loopback cell. See Section 15.1 ATM CELL LOOPBACK.
•
D2ULB When set, this enables the ATM Down2Up loopback circuit. Any incoming cells from the UTOPIA interface which match
the format of ALBCF3–ALBCF0, masked by the ALFLT3–ALFLT0 registers, are not stored in the FIB traffic queue but transmitted
back out over the UTOPIA interface. See Section 15.1 ATM CELL LOOPBACK.
www.national.com
48
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
•
U2DLB When set, this enables the ATM Up2Down loopback circuit. Any incoming cells from the active LVDS receive port which
match the format of ALBCF3–ALBCF0 registers, masked by the ALFLT3–ALFLT0 registers, are not stored in the MTB traffic
queue but transmitted back out over the LVDS transmitter. Note that although there are two independent receivers, this loopback
is designed to operate on live traffic and so only affects cells from the active receiver as defined by the LBA bit of the LKSC
register. See Section 15.1 ATM CELL LOOPBACK.
18.19 ATM LOOPBACK MPhy—0x1B ALBMP
TABLE 39. ALBMP
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
LBMP[4]
LBMP[3]
LBMP[2]
LBMP[1]
LBMP[0]
Type:
Software Lock:
Reset Value:
Read/Write
No
0x00
The ATM Loopback MPhy register defines the MPhy address attached to the ATM lback cell. Setting the TXLVLB bit in the
ALBC register initiates these loopback cells.
•
LBMP[4:0] ATM loopback cell five bit MPhy address.
18.20 ATM LOOPBACK CELL FORMAT —0x1C to 0x1F ALBCF3 to ALF0
TABLE 40. ALBCF3–BCF0
7
6
5
4
3
2
1
0
ALBCF3 0x1C
ALBCF2 0x1D
ALBCF1 0x1E
ALBCF0 0x1F
ALBCF3[7] ALBCF3[6] ALBCF3[5] ALBCF3[4]
ALBCF2[7] ALBCF2[6] ALBCF2[5] ALBCF2[4]
ALBCF1[7] ALBCF1[6] ALBCF1[5] AL1[4]
ALBCF0[7] ALBCF0[6] ALBCF0[5] ALBCF
B3[3]
ALCF2[3]
LBCF1[3]
ALBCF0[3]
ALBCF3[2] ALBCF3[1]
ALBCF2[2] ALBCF2[1]
ALBCF1[2] ALBCF1[1]
ALBCF0[2] ALBCF0[1]
ALBCF3[0]
ALBCF2[0]
ALBCF1[0]
ALBCF0[0]
Type:
Software Lock:
Reset Value:
Read/Write
No
0x00
The ALBCF3, ALBCF2, ALBCF1 and ALBCFegifine the format of the ATM loopback cell header.
•
•
•
•
ALBCF3[7:0] Loopback Cell header byte H1 format.
ALBCF2[7:0] Loopback Cell headeH2 form
ALBCF1[7:0] Loopback Cell heamat.
ALBCF0[7:0] Loopback Cell heademat.
18.21 RECEIVE PORT A LIN—0x20 RALL
TABLE 41. RALL
7
6
5
4
3
2
1
0
RALL[7]
RALL[6]
RALL[5]
RALL[4]
RALL[3]
RALL[2]
RALL[1]
RALL[0]
Type:
Software Lock:
Reset Value:
Read only
No
0x00
The Receive Port A Link Label register contains the Link Trace Label byte received in TC6 on receive Port A. Whenever the received
link label changes value, the RALLC alarm bit in the RALA register is set, which will raise an interrupt if the corresponding interrupt
enable bit is set.
•
RALL[7:0] Port A Received Link Trace Label byte contents.
49
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
18.22 RECEIVE PORT A EXPECTED LINK LABEL—0x21 RAELL
TABLE 42. RAELL
7
6
5
4
3
2
1
0
RAELL[7]
RAELL[6]
RAELL[5]
RAELL[4]
RAELL[3]
RAELL[2]
RAELL[1]
RAELL[0]
Type:
Software Lock:
Reset Value:
Read only
No
0x00
The Receive Port A Expected Link Label register defines the expected contents of the Link Trace Label byte received in TC6 on
receive Port A. If the actual received value, as stored in the RALL register is not the same as the expected value defined here the
RALLM alarm bit in the RALA register is set, which may raise a processor interrupt if the corresponding interrupt enable is set.
•
RAELL[7:0] Port A Expected Received Link Trace Label byte contents.
18.23 RECEIVE PORT A LOCAL ALARMS —0x22 RALA
TABLE 43. RALA
7
6
5
4
3
2
1
0
Reserved
RALLC
RALLM
RALCS
RALDSLL
TCLL
RALFF
ERABF
Type:
Bits[6:1] Read only/Clear on ad
Bit[0] Read/Write
Software Lock:
Reset Value:
No
0x00
The Receive Port A Local Alarms register contains information e status the Port A disassembler. When set RALLC, RALLM,
RALDSLL, RALTCLL and RALFLL will raise an interrupt if the corrng interrupt enable bits are set. Also a change in value
on RALDSLL, RALTCLL or RALFLL will set the RALCS h will an interrupt if the corresponding interrupt enable bit is
set.
•
•
•
•
•
•
RALLC Receive Port A, Local Link Label Change = Change in RALL register value.
RALLM Receive Port A, Local Link Label Mismatcheived link label RALL different than expected link label RAELL.
RALCS Receive Port A, Local Change of Sus. Set = change in value of RALDSLL, RALTCLL or RALFLL bits
RALDSLL Receive Port A, Local Descramer LLock. Set = Out of Lock and Clear = Lock.
RALLTCLL Receive Port A, Local TransporontainDelineation Loss of Lock. Set = Out of Lock and Clear = Lock.
RALFLL Receive Port A, Local Framlineation ss of Lock. Set = Out of Lock and Clear = Lock.
The ERABF register bit indicates thave section for Port A has successfully received a full ECC message consisting
of the 8 data bytes contained in registRAD0, and the message can now be read by the processor.
On reset, the ERABF will be cleicatinalid message has been received. When a valid message is received and stored
in the ERAD7–ERAD0 data rERABF bit will be set and will raise an interrupt if the corresponding interrupt enable bit
is set. Therefore, the procesa received message on the interrupt or by polling the ERABF bit. When the processor
has finished reading the meERAD7–ERAD0 data registers and is ready to receive a new message it simply clears
the ERABF bit. When a full ms been successfully received this is communicated to the far-end device via the ECC
signalling.
•
ERABF The ERABF bit, when set, indicates that ERAD7–ERAD0 data registers contain a full valid received message. The data
in the ERAD7–ERAD0 data registers cannot be overwritten with a new received message while ERABF is set. When ERABF
is cleared this allows the ERAD7–ERAD0 data registers to be overwritten with a new received message.
18.24 RECEIVE PORT A LOCAL INTERRUPT ENABLES—0x23 RALIE
TABLE 44. RALIE
7
6
5
4
3
2
1
0
Reserved
RALLCIE
RALLMIE
RALCSIE RALDSLLIE RALTCLLIE RALFLLIE
ERABFIE
Type:
Software Lock:
Reset Value:
Read/Write
No
0x00
www.national.com
50
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
This register contains the interrupt enables for the alarms in the RALA register. Set = interrupt enabled and Clear = interrupt
disabled.
18.25 RECEIVE PORT A CONTROL—0x24 RACTL
TABLE 45. RACTL
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
RAESS
RABEC
RADFLK
RACDIS
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x01
The Receive Port A Control register defines the operation of the Port A TCS DisAssembler section.
•
RAESS Receive Port A, Valid Received ESS bit select. Two ESS bits are received in the Remote Alarm and Signaling Byte as
described in Section 6.3.7.1 Remote Alarm and Signaling Byte. Only one of these reived bits may be designated as valid.
The valid bit is extracted and passed to the ECC transmit section as the ECC signg (ESS) received on Port A. When
RAESS is set then the Remote Alarm and Signaling Byte bit[1], ESSB, is selected d anbit[2], ESSA is ignored. When
RAESS is clear then the Remote Alarm and Signaling Byte bit[2], ESSA, is scted alind bit[1], ESSB is ignored. The
names ESSA and ESSB of these bits refers to the remote receiver port from ich they orated and are not associated with
the local receivers Port A and Port B. See Section 16.0 Embedded Comon Channel Operation.
•
RABEC Receive Port A, Bit Error Count mode. When set the receiver expects to ive the raw scrambler PRBS pattern. See
TXPRBS bit of the TERRCTL register. The descrambler will lock to tsequence athen count individual bit errors in the
PRBS stream. This bit error count will be refiected in the RABEC2ABEregisters. As there is no data cell delineation, the
frame delineation will be lost. This is not a live traffic test.
•
•
RADFLK Receive Port A, Descrambler Force Lock. When set the desblwill be forced out of lock and will immediately
begin to re-lock. The hardware will clear this bit and the descrambler lock us can be monitored on the RALDSLL bit of the
RALA register, see Section 18.23 RECEIVE PORT A LOCALARMS —0x22 RALA.
RACDIS Receive Port A, Cell Discard. When set then cells wierrd HEC are discarded.
18.26 ECC RECEIVE BUFFER A—0x26 to 0x2D ERD0
TA7–ERAD0
7
6
4
3
2
1
0
ERAD7 0x26
ERAD6 0x27
ERAD5 0x28
ERAD4 0x29
ERAD3 0x2A
ERAD2 0x2B
ERAD7[7]
ERAD6[7]
ERAD5[7]
ERAD4[7]
ERAD3[7]
ERAD2[7]
ERAD7[6]
ERAD6[6]
ERAD5[6
ERAD
ERAD3[6
E6]
EAD7
ERAD6[5]
ERAD5[5
4[5]
3[5]
D2[5]
ERAD1[5]
ERAD0[5]
ERAD7[4]
ERAD6[4]
ERAD5[4]
ERAD4[4]
ERAD3[4]
ERAD2[4]
ERAD1[4]
ERAD0[4]
ERAD7[3]
ERAD6[3]
ERAD5[3]
ERAD4[3]
ERAD3[3]
ERAD2[3]
ERAD1[3]
ERAD0[3]
ERAD7[2]
ERAD6[2]
ERAD5[2]
ERAD4[2]
ERAD3[2]
ERAD2[2]
ERAD1[2]
ERAD0[2]
ERAD7[1]
ERAD6[1]
ERAD5[1]
ERAD4[1]
ERAD3[1]
ERAD2[1]
ERAD1[1]
ERAD0[1]
ERAD7[0]
ERAD6[0]
ERAD5[0]
ERAD4[0]
ERAD3[0]
ERAD2[0]
ERAD1[0]
ERAD0[0]
ERAD1 0x2C ERAD1[7]
ERAD0 0x2D ERAD0[7]
Type:
Read only
Software Lock:
Reset Value:
No
0x00
The ERAD7, ERAD6, ERAD5, ERAD4, ERAD3, ERAD2, ERAD1 and ERAD0 registers contain the Port A received ECC message.
•
ERAD7–ERAD0 When the ERABF bit is set then these registers contain a valid received ECC message for Port A and cannot
be overwritten by any incoming messages. When the ERABF bit is clear these registers may not contain a valid message and
should not be interpreted as such.
51
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.27 RECEIVE PORT A HEC COUNT—0x2E to 0x30 RAHECC2 to RAHECC0
TABLE 47. RAHECC2–RAHECC0
7
6
5
4
3
2
1
0
RAHECC2
0x2E
RAHECC2[7] RAHECC2[6] RAHECC2[5] RAHECC2[4] RAHECC2[3] RAHECC2[2] RAHECC2[1] RAHECC2[0]
RAHECC1[7] RAHECC1[6] RAHECC1[5] RAHECC1[4] RAHECC1[3] RAHECC1[2] RAHECC1[1] RAHECC1[0]
RAHECC0[7] RAHECC0[6] RAHECC0[5] RAHECC0[4] RAHECC0[3] RAHECC0[2] RAHECC0[1] RAHECC0[0]
RAHECC1
0x2F
RAHECC0
0x30
Type:
Read only/Clear on Read
Software Lock:
Reset Value:
No
0x00
The RAHECC2, RAHECC1 and RAHECC0 registers contain the Port A received errorHEC count.
•
RAHECC2–RAHECC0 This register must be read in the order of most significant RHEC2 first and least significant byte
RAHECC0 last or the value read will not be valid. This counter will not roll-ovfrom FFto 0x000000 but will stick at
0xFFFFFF.
18.28 RECEIVE PORT A HEC THRESHOLD—0x31 to 0x33 RAHECT2 to RAHE
TABLE 48. RAHECT2AHECT0
7
6
5
4
3
2
1
0
RAHECT2
0x31
RAHECT2[7] RAHECT2[6] RAHECT2[5] RAHECT2[4] RAT2[3] RAHECT2[2] RAHECT2[1] RAHECT2[0]
RAHECT1[7] RAHECT1[6] RAHECT1[5] RAHEC] HECT1[3] RAHECT1[2] RAHECT1[1] RAHECT1[0]
RAHECT0[7] RAHECT0[6] RAHECT00[4] RAHECT0[3] RAHECT0[2] RAHECT0[1] RAHECT0[0]
RAHECT1
0x32
RAHECT0
0x33
Type:
Read/Write
Software Lock:
Reset Value:
No
0xFF
The RAHECT2, RAHECT1 and RAHEgisters cntain the Port A received erred HEC threshold. When the error count RA-
HECC equals the threshold RAHECHEC alarm will be set.
These registers should not be set to all
•
RAHECT2–RAHECT0 Mont bytRAHECT2 and least significant byte RAHECT0.
18.29 RECEIVE PORT A Bx34 to 0x36 RABIPC2 to RABIPC0
TABLE 49. RABIPC2–RABIPC0
7
6
5
4
3
2
1
0
RABIPC2
0x34
RABIPC2[7] RABIPC2[6] RABIPC2[5] RABIPC2[4] RABIPC2[3] RABIPC2[2] RABIPC2[1] RABIPC2[0]
RABIPC1[7] RABIPC1[6] RABIPC1[5] RABIPC1[4] RABIPC1[3] RABIPC1[2] RABIPC1[1] RABIPC1[0]
RABIPC0[7] RABIPC0[6] RABIPC0[5] RABIPC0[4] RABIPC0[3] RABIPC0[2] RABIPC0[1] RABIPC0[0]
RABIPC1
0x35
RABIPC0
0x36
Type:
Read only/Clear on Read
Software Lock:
Reset Value:
No
0x00
The RABIPC2, RABIPC1 and RABIPC0 registers contain the Port A received errored BIP count.
www.national.com
52
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
•
RABIPC2–RABIPC0 This register must be read in the order of most significant byte RABIPC2 first and least significant byte
RABIPC0 last or the value read will not be valid. This counter will not roll-over from 0xFFFFFF to 0x000000 but will stick at
0xFFFFFF.
18.30 RECEIVE PORT A BIP THRESHOLD—0x36 to 0x39 RABIPT2 to RABIPT0
TABLE 50. RABIPT2–RABIPT0
7
6
5
4
3
2
1
0
RABIPT2
0x37
RABIPT2[7] RABIPT2[6] RABIPT2[5] RABIPT2[4] RABIPT2[3] RABIPT2[2] RABIPT2[1] RABIPT2[0]
RABIPT1[7] RABIPT1[6] RABIPT1[5] RABIPT1[4] RABIPT1[3] RABIPT1[2] RABIPT1[1] RABIPT1[0]
RABIPT0[7] RABIPT0[6] RABIPT0[5] RABIPT0[4] RABIPT0[3] RABIPT0[2] RABIPT0[1] RABIPT0[0]
RABIPT1
0x38
RABIPT0
0x39
Type:
Read/Wri
Software Lock:
Reset Value:
No
0xFF
The RABIPT2, RABIPT1 and RABIPT0 registers contain the Port A received ed BIP thresold. When the error count RABIPC
equals the threshold RABIPT then the RAXBIP alarm will be set.
These registers should not be set to all zeroes.
•
RABIPT2–RABIPT0 Most significant byte RABIPT2 and least sigant te RABIPT0.
18.31 RECEIVE PORT A PERFORMANCE ALARMS—0x3A RAPA
TABLE RAPA
7
6
5
2
1
0
Reserved
Reserved
Reserved
R
eserved
Reserved
RAXHEC
RAXBIP
Type:
Rer on Read
Software Lock:
Reset Value:
No
The Receive Port A Performance Alarms register contaiinformation about the error performance of Port A. When set RAXHEC
and RAXBIP will raise an interrupt if thspondinnterrupt enable bits are set.
•
•
RAXHEC Receive Port A, Exces. Set = Number of HEC errors counted in RAHECC is equal to or greater than
the threshold set in RAHECT. This ben RAHECC = RAHECT and can only be cleared by a read of this register.
RAXBIP Receive Port A, Exce BIP s. Set = Number of BIP errors counted in RABIPC is equal to or greater than the
threshold set in RABIPT. t when RABIPC = RABIPT and can only be cleared by a read of this register.
18.32 RECEIVE PORT A PEE INTERRUPT ENABLES—0x3B RAPIE
TABLE 52. RAPIE
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved RAXHECIE RAXBIPIE
Type:
Read/Write
Software Lock:
Reset Value:
No
0x00
This register contains the interrupt enables for the alarms in the RAPA register. Set = interrupt enabled and Clear = interrupt
disabled.
53
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.33 RECEIVE PORT A REMOTE STATUS AND ALARMS—0x3C RARA
TABLE 53. RARA
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
RARCS
RARLOSA RARLOSB
RARBA
RARDSLL
Type:
Bits[4:2] and [0] Read only/Clear on Read
Bit[1] Read only
Software Lock:
Reset Value:
No
0x0D
The Receive Port A Remote Status and Alarms register contains information on the status of the far-end device, which is connected
to Port A. On a local Loss of Signal on Port A, LLOSA alarm, these bits return to their reset values. When set, the RARLOSA,
RARLOSB, RARBA, and RARDSLL bits will raise an interrupt if the corresponding interrupt enable is set. Also, a change in value
on RARLOSA, RARLOSB, RARDSLL or RARBA will set the RARCS bit. When set, the RARCS bit will raise an interrupt if the
corresponding interrupt enable is set.
•
•
•
•
RARCS Receive Port A, Remote Change of Status at far end device LVDS receiPort
RARLOSA Receive Port A, Remote Loss Of Signal at far end device LVDS receiA.
RARLOSB Receive Port A, Remote Loss Of Signal at far end device LVDS eive P.
RARBA Receive Port A, Remote far end device active receive Port. Set = B active aClear = Port A active. Note that
this bit, if set, will not clear on a read of this register.
•
RARDSLL Receive Port A, Remote far end device active receive port Descramblss of Lock. Set = Out of Lock and Clear
= Lock.
18.34 RECEIVE PORT A REMOTE INTERRUPT ENABLES—0x3D R
TABLE 54. RARIE
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
RARRARAI RARLOSBI RARBAIE RARDSLLI
E
E
E
Type:
Software Lock:
Reset Value:
Read/Write
No
0x00
This register contains the interrupt enables for the alas in the RARA register. Set = interrupt enabled and Clear = interrupt
disabled.
18.35 RECEIVE PORT A UP2DOWN CELL COUNT—0x3E RAU2DLBC
TABLE 55. RAU2DLBC
7
6
4
3
2
1
0
RAU2DLBC RAU2DLBLBC RAU2DLBC RAU2DLBC
[7] [6] [5] [4] [3]
RAU2DLBC
[2]
RAU2DLBC
[1]
RARECEIVE
PORT B HEC
THRESHOLD
U2DLBC[0]
Type:
Read only/Clear on Read
Software Lock:
Reset Value:
No
0x00
The Receive Port A Up2Down Loopback Cell Count register counts the number of incoming loopback cells detected from the Port
A LVDS interface when Up2Down loopback is enabled with the U2DLB bit of the ALBC register, see Section 18.18 ATM AND
LVDS LOOPBACK CONTROL—0x1A ALBC. Note that this counter is incremented when an incoming loopback cell is received
and that this differs from the functionality of the Down2Up Loopback Cell Count register, see Section 18.71 ATM DOWN2UP
LOOPBACK CELL COUNT—0xE0 D2ULBCC.
•
RAU2DLBC[7:0] Port A Up2Down Loopback Cell Count value. This register will not roll-over from 0x00 to 0xFF but will stick
at 0xFF.
www.national.com
54
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.36 RECEIVE PORT A CELL DELINEATION THRESHOLDS—0x40 RACDT
TABLE 56. RACDT
7
6
5
4
3
2
1
0
ALPHA[3]
ALPHA[2]
ALPHA[1]
ALPHA[0]
DELTA[3]
DELTA[2]
DELTA[1]
DELTA[0]
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x78
The Receive Port A Cell and Transport Container Delineation Thresholds register controls the operation of the Port A cell delineation
state machine. The cell delineation lock status is reflected in the RALTCLL bit of the RALA register.
•
•
ALPHA[3:0] When in lock this is the number of consecutive incorrect cell HEC’s required to lose cell delineation lock.
DELTA[3:0] When out of lock this is the number of consecutive correct cell HEC’s required to gain cell delineation lock.
18.37 RECEIVE PORT A FRAME DELINEATION THRESHOLDS—0x41 RAFDT
TABLE 57. RAFDT
7
6
5
4
3
2
1
0
MU[3]
MU[2]
MU[1]
MU[0]
SIGMA[3
MA[2]
SIGMA[1]
SIGMA[0]
Type:
Software Lock:
Reset Value:
Read/Write
s
x78
The Receive Port A Frame Delineation Thresholds register controls the operan of the Port A frame delineation state machine.
The frame delineation lock status is refiected in the RALFLL bihe RALregister.
•
•
MU[3:0] When in lock this is the number of consecutive incorrecEC’s required to lose frame delineation lock.
SIGMA[3:0] When out of lock this is the number of correct frame HEC’s required to gain frame delineation lock.
18.38 RECEIVE PORT A DESCRAMBLER LOCK TH—0x42 RADSLKT
TABLE 58. RADSLKT
7
6
5
3
2
1
0
PSI[3]
PSI[2]
I[1]
[0]
RHO[3]
RHO[2]
RHO[1]
RHO[0]
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x88
The Receive Port A Descraresholds register controls the operation of the Port A descrambler lock state machine
confidence counter. The desstatus is reflected in the RALDSLL bit of the RALA register.
•
•
PSI[3:0] When in lock this is teshold that the descrambler confidence counter must reach to lose descrambler lock. When
in lock the descrambler confidence counter increments on incorrect HEC predictions and decrements on good HEC predictions.
RHO[3:0] When out of lock this is the threshold that the descrambler confidence counter must reach to gain descrambler lock.
When out of lock the descrambler confidence counter decrements on incorrect HEC predictions and increments on good HEC
predictions.
55
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.39 RECEIVE PORT A BIT ERROR COUNT—0x43 to 0x45 RABEC2 to RABEC0
TABLE 59. RABEC2–RABEC0
7
6
5
4
3
2
1
0
RABEC2
0x43
RABEC2[7] RABEC2[6] RABEC2[5] RABEC2[4] RABEC2[3] RABEC2[2] RABEC2[1] RABEC2[0]
RABEC1[7] RABEC1[6] RABEC1[5] RABEC1[4] RABEC1[3] RABEC1[2] RABEC1[1] RABEC1[0]
RABEC0[7] RABEC0[6] RABEC0[5] RABEC0[4] RABEC0[3] RABEC0[2] RABEC0[1] RABEC0[0]
RABEC1
0x44
RABEC0
0x45
Type:
Read only/Clear on Read
Software Lock:
Reset Value:
No
0x00
The RABEC2, RABEC1 and RABEC0 registers contain the Port A received bit error cot whenever the RABEC bit of the RACTL
register is set. If the RABEC bit of the RACTL register is clear these registers are cld.
•
RABEC2–RABEC0 This register must be read in the order of most significanbyte RC2 st and least significant byte
RABEC0 last, or the value read will not be valid. This counter will not roll-ovfrom 0xFF to 0x000000 but will stick at
0xFFFFFF.
18.40 RECEIVE PORT B LINK LABEL—0x60 RBLL
TABLE 60. R
7
6
5
4
3
2
1
0
RBLL[7]
RBLL[6]
RBLL[5]
RBLL[4]
RBLL[3]
RBLL[2]
RBLL[1]
RBLL[0]
Type:
Software Lock:
Reset Value:
Read only
No
0x00
The Receive Port B Link Label register contains the Link l byte received in TC6 on receive Port B. Whenever the received
link label changes value, the RBLLC alarm bit ihe RBLA register is set, which will raise an interrupt if the corresponding interrupt
enable bit is set.
•
RBLL[7:0] Port B Received Link Trace Label byte coents.
18.41 RECEIVE PORT B EXPECTEL—0x61 RBELL
TABLE 61. RBELL
7
5
4
3
2
1
0
RBELL[7]
R
ELL[5]
RBELL[4]
RBELL[3]
RBELL[2]
RBELL[1]
RBELL[0]
Type:
Software Lock:
Reset Value:
Read/Write
No
0x00
The Receive Port B Expected Link Label register defines the expected contents of the Link Trace Label byte received in TC6 on
receive Port B. If the actual received value, as stored in the RBLL register is not the same as the expected value defined here the
RBLLM alarm bit in the RBLA register is set, which may raise a processor interrupt if the corresponding interrupt enable is set.
•
RBELL[7:0] Port B Expected Received Link Trace Label byte contents.
www.national.com
56
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.42 RECEIVE PORT B LOCAL ALARMS—0x62 RBLA
TABLE 62. RBLA
7
6
5
4
3
2
1
0
Reserved
RBLLC
RBLLM
RBLCS
RBLDSLL
RBLTCLL
RBLFLL
ERBBF
Type:
Bits[6:1] Read only/Clear on Read
Bit[0] Read/Write
Software Lock:
Reset Value:
No
0x00
The Receive Port B Local Alarms register contains information on the status of the Port B disassembler. When set, RBLLC, RBLLM,
RBLDSLL, RBLTCLL, and RBLFLL will raise an interrupt if the corresponding interrupt enable bits are set. Also, a change in value
on RBLDSLL, RBLTCLL and RBLFLL will set the RBLCS bit, which will raise an interrupt if the corresponding interrupt enable bit
is set.
•
•
•
•
•
•
RBLLC Receive Port B, Local Link Label Change of Status. Set = Change in RBLL gister value.
RBLLM Receive Port B, Local Link Label Mismatch. Set = Received link label RBdiffnt than expected link label RBELL.
RBLCS Receive Port B, Local Change of Status. Set = change in value of RBLDSLTCor RBLFLL bits.
RBLDSLL Receive Port B, Local Descrambler Loss of Lock. Set = Out of Loand Clock.
RBLTCLL Receive Port B, Local Transport Container Delineation Loss of . Set = Out f Lock and Clear = Lock.
RBLFLL Receive Port B, Local Frame Delineation Loss of Lock. Set = Oof and Clear = Lock.
The ERBBF register bit indicates that the ECC receive section for Port B s successfulreceived a full ECC message consisting
of the 8 data bytes contained in registers ERBD7–ERBD0 and a the msagcan now be read by the processor.
On reset, the ERBBF will be clear indicating no valid message has beeiveWhen a valid message is received and stored
in the ERBD7–ERBD0 data registers, the ERBBF bit will be set and will raiterrupt if the corresponding interrupt enable bit
is set. Therefore, the processor can detect a received messagon the interrupor by polling the ERBBF bit. When the processor
has finished reading the message from the ERBD7–ERBD0 dagisters ad is ready to receive a new message, it simply clears
the ERBBF bit. When a full message has been successfully rece, tis communicated to the far-end device via the ECC
signalling.
•
ERBBF The ERBBF bit, when set, indicates that Edata registers contain a full valid received message. The data
in the ERBD7–ERBD0 data registers cannot be ova new received message while ERBBF is set. When ERBBF
is cleared, this allows the ERBD7–ERBD0 data regioverwritten with a new received message.
18.43 RECEIVE PORT B LOCAL INTERRUENS—0x63 RBLIE
BLE 63. RBLIE
7
6
4
3
2
1
0
Reserved
RBLLCIE
RBLCSIE RBLSLLIE RBLTCLLIE RBLFLLIE
ERBBFIE
Type:
Software Lock:
Reset Value:
Read/Write
No
0x00
This register contains the interrupt enables for the alarms in the RBLA register. Set = interrupt enabled and Clear = interrupt
disabled.
57
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.44 RECEIVE PORT B CONTROL—0x64 RBCTL
TABLE 64. RBCTL
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
RBESS
RBBEC
RBDFLK
RBCDIS
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x01
The Receive Port B Control register defines the operation of the Port B TCS DisAssembler section.
•
RBESS Receive Port B, Valid Received ESS bit select. Two ESS bits are received in the Remote Alarm and Signaling Byte as
described in Section 6.3.7.1 Remote Alarm and Signaling Byte. Only one of these received bits may be designated as valid.
The valid bit is extracted and passed to the ECC transmit section as the ECC signaling bit (ESS) received on Port B. When
RBESS is set, then the Remote Alarm and Signaling Byte bit[1], ESSB, is selected as valid and bit[2], ESSA is ignored. When
RBESS is clear then the Remote Alarm and Signaling Byte bit[2], ESSA, is selected s valid and bit[1], ESSB is ignored. The
names ESSA and ESSB of these bits refers to the remote receiver port from which ey oinated and are not associated with
the local receivers Port A and Port B. See Section 16.0 Embedded Communicathnel Operation.
•
RBBEC Receive Port B, Bit Error Count mode. When set the receiver expects recehe w scrambler PRBS pattern. See
TXPRBS bit of the TERRCTL register. The descrambler will lock to this seqnce and thount individual bit errors in the
PRBS stream. This bit error count will be refiected in the RBBEC2–RBBEisters. As there is no data cell delineation, the
frame delineation will be lost. This is not a live traffic test.
•
•
RBDFLK Receive Port B, Descrambler Force Lock. When set the deambler will forced out of lock and will immediately
begin to re-lock. The hardware will clear this bit and the descramblock tatus can be monitored on the RBLDSLL bit of the
RBLA register, see Section 18.42 RECEIVE PORT B LOCAL ALSx62 RBLA.
RBCDIS Receive Port B, Cell Discard. When set then cells with an erd Hare discarded.
18.45 ECC RECEIVE BUFFER B—0x66 to 0x6D ERBD7 to D0
TABLE 65. ERBDBD0
7
6
5
3
2
1
0
ERBD7 0x66
ERBD6 0x67
ERBD5 0x68
ERBD4 0x69
ERBD3 0x6A
ERBD2 0x6B
ERBD7[7]
ERBD6[7]
ERBD5[7]
ERBD4[7]
ERBD3[7]
ERBD2[7]
ERBD7[6]
ERBD6[6]
ERBD5[6]
ERBD4[6]
ERBD3[6]
ERBD2[
ERBD1
ERBD0[6]
ERBD7[5
ERBD6[5]
ED5[5]
E]
ERBD3[5]
RD2[5]
[5]
0[5]
4]
6[4]
ERBD5[4]
ERBD4[4]
ERBD3[4]
ERBD2[4]
ERBD1[4]
ERBD0[4]
ERBD7[3]
ERBD6[3]
ERBD5[3]
ERBD4[3]
ERBD3[3]
ERBD2[3]
ERBD1[3]
ERBD0[3]
ERBD7[2]
ERBD6[2]
ERBD5[2]
ERBD4[2]
ERBD3[2]
ERBD2[2]
ERBD1[2]
ERBD0[2]
ERBD7[1]
ERBD6[1]
ERBD5[1]
ERBD4[1]
ERBD3[1]
ERBD2[1]
ERBD1[1]
ERBD0[1]
ERBD7[0]
ERBD6[0]
ERBD5[0]
ERBD4[0]
ERBD3[0]
ERBD2[0]
ERBD1[0]
ERBD0[0]
ERBD1 0x6C ERBD1[7]
ERBD0 0x6D ERBD0[7]
Type:
Read only
Software Lock:
Reset Value:
No
0x00
The ERBD7, ERBD6, ERBD5, ERBD4, ERBD3, ERBD2, ERBD1, and ERBD0 registers contain the Port B received ECC message.
•
ERBD7–ERBD0 When the ERBBF bit is set, then these registers contain a valid received ECC message for Port B and cannot
be overwritten by any incoming messages. When the ERBBF bit is clear, these registers may not contain a valid message and
should not be interpreted as such.
www.national.com
58
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.46 RECEIVE PORT B HEC COUNT—0x6E to 0x70 RBHECC2 to RBHECC0
TABLE 66. RBHECC2–RBHECC0
7
6
5
4
3
2
1
0
RBHECC2
0x6E
RBHECC2[7] RBHECC2[6] RBHECC2[5] RBHECC2[4] RBHECC2[3] RBHECC2[2] RBHECC2[1] RBHECC2[0]
RBHECC1[7] RBHECC1[6] RBHECC1[5] RBHECC1[4] RBHECC1[3] RBHECC1[2] RBHECC1[1] RBHECC1[0]
RBHECC0[7] RBHECC0[6] RBHECC0[5] RBHECC0[4] RBHECC0[3] RBHECC0[2] RBHECC0[1] RBHECC0[0]
RBHECC1
0x6F
RBHECC0
0x70
Type:
Read only/Clear on Read
Software Lock:
Reset Value:
No
0x00
The RBHECC2, RBHECC1 and RBHECC0 registers contain the Port B received errorHEC count.
•
RBHECC2–RBHECC0 This register must be read in the order of most significant RHEC2 first and least significant byte
RBHECC0 or the value read will not be valid. This counter will not roll-over fro0xFFF 0x000000 but will stick at
0xFFFFFF.
18.47 RECEIVE PORT B HEC THRESHOLD—0x71 to 0x73 RBHECT2 to RBHE
TABLE 67. RBHECT2BHECT0
7
6
5
4
3
2
1
0
RBHECT2
0x71
RBHECT2[7] RBHECT2[6] RBHECT2[5] RBHECT2[4] RBT2[3] RBHECT2[2] RBHECT2[1] RBHECT2[0]
RBHECT1[7] RBHECT1[6] RBHECT1[5] RBHEC] HECT1[3] RBHECT1[2] RBHECT1[1] RBHECT1[0]
RBHECT0[7] RBHECT0[6] RBHECT00[4] RBHECT0[3] RBHECT0[2] RBHECT0[1] RBHECT0[0]
RBHECT1
0x72
RBHECT0
0x73
Type:
Read/Write
Software Lock:
Reset Value:
No
0xFF
The RBHECT2, RBHECT1 and RBHEgisters cntain the Port B received erred HEC threshold. When the error count RB-
HECC equals the threshold RBHECXHEC alarm will be set.
These registers should not be set to all
•
RBHECT2–RBHECT0 Mont bytRBHECT2 and least significant byte RBHECT0.
18.48 RECEIVE PORT B Bx74 to 0x76 RBBIPC2 to RBBIPC0
TABLE 68. RBBIPC2–RBBIPC0
7
6
5
4
3
2
1
0
RBBIPC2
0x74
RBBIPC2[7] RBBIPC2[6] RBBIPC2[5] RBBIPC2[4] RBBIPC2[3] RBBIPC2[2] RBBIPC2[1] RBBIPC2[0]
RBBIPC1[7] RBBIPC1[6] RBBIPC1[5] RBBIPC1[4] RBBIPC1[3] RBBIPC1[2] RBBIPC1[1] RBBIPC1[0]
RBBIPC0[7] RBBIPC0[6] RBBIPC0[5] RBBIPC0[4] RBBIPC0[3] RBBIPC0[2] RBBIPC0[1] RBBIPC0[0]
RBBIPC1
0x75
RBBIPC0
0x76
Type:
Read only/Clear on Read
Software Lock:
Reset Value:
No
0x00
The RBBIPC2, RBBIPC1 and RBBIPC0 registers contain the Port B received errored BIP count.
59
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
•
RBBIPC2–RBBIPC0 This register must be read in the order of most significant byte RBBIPC2first and least significant byte
RBBIPC0 or the value read will not be valid. This counter will not roll-over from 0xFFFFFF to 0x000000 but will stick at 0xFFFFFF.
18.49 RECEIVE PORT B BIP THRESHOLD—0x77 to 0x79 RBBIPT2 to RBBIPT0
TABLE 69. RBBIPT2–RBBIPT0
7
6
5
4
3
2
1
0
RBBIPT2
0x77
RBBIPT2[7] RBBIPT2[6] RBBIPT2[5] RBBIPT2[4] RBBIPT2[3] RBBIPT2[2] RBBIPT2[1] RBBIPT2[0]
RBBIPT1[7] RBBIPT1[6] RBBIPT1[5] RBBIPT1[4] RBBIPT1[3] RBBIPT1[2] RBBIPT1[1] RBBIPT1[0]
RBBIPT0[7] RBBIPT0[6] RBBIPT0[5] RBBIPT0[4] RBBIPT0[3] RBBIPT0[2] RBBIPT0[1] RBBIPT0[0]
RBBIPT1
0x78
RBBIPT0
0x79
Type:
Read/Write
Software Lock:
Reset Value:
No
0xFF
The RBBIPT2, RBBIPT1 and RBBIPT0 registers contain the Port B received erBIP thr. When the error count RBBIPC
equals the threshold RBBIPT, then the RBXBIP alarm will be set.
These registers should not be set to all zeroes.
•
RBBIPT2–RBBIPT0 Most significant byte RBBIPT2 and least signint byte RBBIPT0.
18.50 RECEIVE PORT B PERFORMANCE ALARMS—0x7A RBPA
TABLE 70. RBPA
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Re
Resed
Reserved
RBXHEC
RBXBIP
Type:
Ron Read
Software Lock:
Reset Value:
No
0x00
The Receive Port B Performance Alarms registainformation about the error performance of Port B. When set RBXHEC
and RBXBIP will raise an interrupt if the corresponding errupt enable bits are set.
•
•
RBXHEC Receive Port B, Excessirs. Set = Number of HEC errors counted in RBHECC is equal to or greater than
the threshold set in RBHECT. Thn RBHECC = RBHECT and can only be cleared by a read of this register.
RBXBIP Receive Port B, Excessive Set = Number of BIP errors counted in RBBIPC is equal to or greater than the
threshold set in RBBIPT. This set wRBBIPC = RBBIPT and can only be cleared by a read of this register.
18.51 RECEIVE PORT B PE INTERRUPT ENABLES—0x7B RBPIE
TABLE 71. RBPIE
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved RBXHECIE RBXBIPIE
Type:
Read/Write
Software Lock:
Reset Value:
No
0x00
This register contains the interrupt enables for the alarms in the RBPA register. Set = interrupt enabled and Clear = interrupt
disabled.
www.national.com
60
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.52 RECEIVE PORT B REMOTE STATUS AND ALARMS—0x7C RBRA
TABLE 72. RBRA
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
RBRCS
RBRLOSA RBRLOSB
RBRBA
RBRDSLL
Type:
Bits[4:2] and [0] Read only/Clear on Read
Bit[1] Read only
Software Lock:
Reset Value:
No
0x0D
The Receive Port B Remote Status and Alarms register contains information on the status of the far-end device, which is connected
to Port B. On a local Loss of Signal on Port B, LLOSB alarm, these bits return to their reset values. When set, the RBRLOSA,
RBRLOSB, RBRBA, and RBRDSLL bits will raise an interrupt if the corresponding interrupt enable is set. Also, a change in value
on RBRLOSA, RBRLOSB, RBRDSLL or RBRBA will set the RBRCS bit. When set, the RBRCS bit will raise an interrupt if the
corresponding interrupt enable is set.
•
•
•
•
RBRCS Receive Port B, Remote Change of Status at far end device LVDS receiPort
RBRLOSA Receive Port B, Remote Loss Of Signal at far end device LVDS receiA.
RBRLOSB Receive Port B, Remote Loss Of Signal at far end device LVDS eive P.
RBRBA Receive Port B, Remote far end device active receive Port. Set = B active aClear = Port A active. Note that
this bit, if set, will not clear on a read of this register.
•
RBRDSLL Receive Port B, Remote far end device active receive port Descramblss of Lock. Set = Out of Lock and Clear
= Lock.
18.53 RECEIVE PORT B REMOTE INTERRUPT ENABLES—0x7D R
TABLE 73. RBRIE
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
RBRRBRSAI RBRLOSBI RBRBAIE RBRDSLLI
E
E
E
Type:
Software Lock:
Reset Value:
Read/Write
No
0x00
This register contains the interrupt enables for the alas in the RBRB register. Set = interrupt enabled and Clear = interrupt
disabled.
18.54 RECEIVE PORT B UP2DOWN CELL COUNT—0x7E RBU2DLBC
TABLE 74. RBU2DLBC
7
5
4
3
2
1
0
RBU2DLBC RBUU2DLBC RBU2DLBC RBU2DLBC RBU2DLBC RBU2DLBC RBU2DLBC
[7] [6] [5] [4] [3] [2] [1] [0]
Type:
Read only/Clear on Read
Software Lock:
Reset Value:
No
0x00
The Receive Port B Up2Down Loopback Cell Count register counts the number of incoming loopback cells detected from the Port
B LVDS interface when Up2Down loopback is enabled with the U2DLB bit of the ALBC register, see Section 18.18 ATM AND
LVDS LOOPBACK CONTROL—0x1A ALBC. Note that this counter is incremented when an incoming loopback cell is received
and that this differs from the functionality of the Down2Up Loopback Cell Count register, see Section 18.71 ATM DOWN2UP
LOOPBACK CELL COUNT—0xE0 D2ULBCC.
•
RBU2DLBC[7:0] Port B Up2Down Loopback Cell Count value. This register will not roll-over from 0x00 to 0xFF but will stick
at 0xFF.
61
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.55 RECEIVE PORT B CELL DELINEATION THRESHOLDS—0x80 RBCDT
TABLE 75. RBCDT
7
6
5
4
3
2
1
0
ALPHA[3]
ALPHA[2]
ALPHA[1]
ALPHA[0]
DELTA[3]
DELTA[2]
DELTA[1]
DELTA[0]
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x78
The Receive Port B Cell and Transport Container Delineation Thresholds register controls the operation of the Port B cell delineation
state machine. The cell delineation lock status is refiected in the RBLTCLL bit of the RBLA register.
•
•
ALPHA[3:0] When in lock this is the number of consecutive incorrect cell HEC’s required to lose cell delineation lock.
DELTA[3:0] When out of lock this is the number of consecutive correct cell HEC’s required to gain cell delineation lock.
18.56 RECEIVE PORT B FRAME DELINEATION THRESHOLDS—0x81 RBFDT
TABLE 76. RBFDT
7
6
5
4
3
2
1
0
MU[3]
MU[2]
MU[1]
MU[0]
SIGMA[3
MA[2]
SIGMA[1]
SIGMA[0]
Type:
Software Lock:
Reset Value:
Read/Write
s
x78
The Receive Port B Frame Delineation Thresholds register controls the operan of the Port B frame delineation state machine.
The frame delineation lock status is refiected in the RBLFLL bihe RBLregister.
•
•
MU[3:0] When in lock this is the number of consecutive incorrect EC’s required to lose frame delineation lock.
SIGMA[3:0] When out of lock this is the number of correct frame HEC’s required to gain frame delineation lock.
18.57 RECEIVE PORT B DESCRAMBLER LOCK TH—0x82 RBDSLKT
TABLE 77. RBDSLKT
7
6
5
3
2
1
0
PSI[3]
PSI[2]
I[1]
[0]
RHO[3]
RHO[2]
RHO[1]
RHO[0]
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x88
The Receive Port B Descraresholds register controls the operation of the Port B descrambler lock state machine
confidence counter. The desstatus is refiected in the RBLDSLL bit of the RBLA register.
•
•
PSI[3:0] When in lock this is teshold that the descrambler confidence counter must reach to lose descrambler lock. When
in lock the descrambler confidence counter increments on incorrect HEC predictions and decrements on good HEC predictions.
RHO[3:0] When out of lock this is the threshold that the descrambler confidence counter must reach to gain descrambler lock.
When out of lock the descrambler confidence counter decrements on incorrect HEC predictions and increments on good HEC
predictions.
www.national.com
62
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.58 RECEIVE PORT B BIT ERROR COUNT—0x83 to 0x85 RBBEC2 to RBBEC0
TABLE 78. RBBEC2–RBBEC0
7
6
5
4
3
2
1
0
RBBEC2
0x83
RBBEC2[7] RBBEC2[6] RBBEC2[5] RBBEC2[4] RBBEC2[3] RBBEC2[2] RBBEC2[1] RBBEC2[0]
RBBEC1[7] RBBEC1[6] RBBEC1[5] RBBEC1[4] RBBEC1[3] RBBEC1[2] RBBEC1[1] RBBEC1[0]
RBBEC0[7] RBBEC0[6] RBBEC0[5] RBBEC0[4] RBBEC0[3] RBBEC0[2] RBBEC0[1] RBBEC0[0]
RBBEC1
0x84
RBBEC0
0x85
Type:
Read only/Clear on Read
Software Lock:
Reset Value:
No
0x00
The RBBEC2, RBBEC1 and RBBEC0 registers contain the Port B received bit error cot whenever the RBBEC bit of the RBCTL
register is set. If the RBBEC bit of the RBCTL register is clear, these registers are ced.
•
RBBEC2–RBBEC0 This register must be read in the order of most significanbyte C2 st and least significant byte
RBBEC0 last, or the value read will not be valid. This counter will not roll-ovfrom 0xFF to 0x000000 but will stick at
0xFFFFFF.
18.59 UTOPIA CONFIGURATION—0xA0 UCFG
TABLE 79. U
7
6
5
4
3
2
1
0
Reserved
Reserved
CLVM[1]
CLVM[0]
BWIDTH
Reserved
UBDEN
UMODE
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x00
The UTOPIA Configuration register defines the UTOPIoperating modes. The default is ATM Layer Level 2 mode (31
ports) using CLAV0 with16 bit data.
•
CLVM[1:0] Clav Mode bits. 00 = Up to 31 nLAV0, 01 or 10 = Reserved, 11 = Up to 248 ports using CLAV0 to
CLAV7.
•
•
BWIDTH UTOPIA data bus width. S-bit data s and Clear = 16-bit mode.
UBDEN UTOPIA Bidirectional pin= the UTOPIA bidirectional pins take on the functionality as defined by the
UMODE setting. Clear = All UTOPdirectional pins are tri-stated. This is to avoid pin contention at the UTOPIA
pins on reset.
•
UMODE UTOPIA ATM or Pe. Set PHY Layer interface and Clear = ATM Layer Interface.
18.60 UTOPIA CONNECTE—0xA1 to 0xA4 UCPL3 to UCPL0
TABLE 80. UCPL1–UCPL0
7
6
5
4
3
2
1
0
UCPL3 0xA1
UCPL2 0xA2
UCPL1 0xA3
UCPL0 0xA4
Reserved
UCPL2[7]
UCPL1[7]
UCPL0[7]
UCPL3[6]
UCPL2[6]
UCPL1[6]
UCPL0[6]
UCPL3[5]
UCPL2[5]
UCPL1[5]
UCPL0[5]
UCPL3[4]
UCPL2[4]
UCPL1[4]
UCPL0[4]
UCPL3[3]
UCPL2[3]
UCPL1[3]
UCPL0[3]
UCPL3[2]
UCPL2[2]
UCPL1[2]
UCPL0[2]
UCPL3[1]
UCPL2[1]
UCPL1[1]
UCPL0[1]
UCPL3[0]
UCPL2[0]
UCPL1[0]
UCPL0[0]
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0xFF, except UCPL3 = 0x7F
The UCPL3, UCPL2, UCPL1 and UCPL0 registers define the connected UTOPIA ports for polling. The sub-ports present for the
connected ports is defined in the UCSPL register. Note that at least one port has to be connected for correct polling to occur, so
these registers should never be set to all zeroes. See Section 8.0 UTOPIA Interface Operation. If no ports are required then use
of the Configuration Traffic inhibit functionality is recommended. See Section 10.0 Configuration and Traffic Inhibit Operation.
63
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
•
UCPL3–UCPL0 UCPL3[6] corresponds to port 31 and UCPL0[0] corresponds to port 0. When a bit is set then the port is
connected and will be polled, when clear the port is not connected and will not be polled.
18.61 UTOPIA CONNECTED SUB-PORT LIST—0xA6 UCSPL
TABLE 81. UCSPL
7
6
5
4
3
2
1
0
UCSPL[7]
UCSPL[6]
UCSPL[5]
UCSPL[4]
UCSPL[3]
UCSPL[2]
UCSPL[1]
UCSPL[0]
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x01
The UCSPL register defines the connected UTOPIA sub-ports within all ports for polling.
•
UCSPL UCSPL[7] corresponds to sub-port 7 (CLAV7) and UCSPL[0] corresponds to sub-port 0 (CLAV0). When a bit is set,
then the sub-port is connected and will be polled; when clear, the sub-port is not coected and will not be polled.
18.62 UTOPIA SUB-PORT ADDRESS LOCATION—0xA7 USPAL
TABLE 82. USPAL
7
6
5
4
3
1
0
Reserved
Reserved
Reserved
USPL[4]
USP]
USPL[2
USPL[1]
USPL[0]
Type:
Software Lock:
Reset Value:
eadrite
0x00
The UTOPIA Sub-Port Address Location register defines which bythDU header the sub-port address is contained in when
using Extended UTOPIA mode. The PDU header consisUser pend, the ATM cell header and UDF bytes, and so can
be a maximum of 18 bytes. The first of these bytes is byte 0. The corresponding USPAM register is used to define
which bits in the byte contain the sub-port address.
•
USPAL[4:0] Byte number of the PDU header byte wns the UTOPIA sub-port address.
18.63 UTOPIA SUB-PORT ADDRESS MAS0xPAM
TBLE 83. USPAM
7
6
4
3
2
1
0
USPAM[7] USPAM[6] USPAM[4] USPAM[3] USPAM[2] USPAM[1] USPAM[0]
Type:
Read/Write
Software Lock:
Reset Value:
Yes
0x07
The UTOPIA Sub-Port Address Mask register defines which bits of the PDU header byte defined by the USPAL register contain
the sub-port address.
•
USPAM[7:0] Set = This bit location contains valid sub-port address bit.Clear = Ignore this bit location.
Note that only 3 bit locations must be set in this register to give the 3 bit sub-port address location. All other bits must be clear. By
default, bits USPAM[2:0] are set, indicating that the sub-port address is located in bits [2:0] of the PDU header byte indicated by
the USPAL register, with the MSB in bit [2] and the LSB in bit [0]. If USPAM bits [6], [4] and [1] were set, then the sub-port address
would be located in bits [6], [4] and [1] of the PDU header byte indicated by the USPAL register, with the MSB in bit [6] and the
LSB in bit [1].
www.national.com
64
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.64 MTB QUEUE THRESHOLD—0xA9 to 0xC7 MTBQT30 to MTBQT0
TABLE 84. MTBQT30–MTBQT0
7
6
5
4
3
2
1
0
MTBQT30
0xA9
MTBQT30[7] MTBQT30[6] MTBQT30[5] MTBQT30[4] MTBQT30[3] MTBQT30[2] MTBQT30[1] MTBQT30[0]
MTBQT29
0xAA
MTBQT29[7] MTBQT29[6] MTBQT29[5] MTBQT29[4] MTBQT29[3] MTBQT29[2] MTBQT29[1] MTBQT29[0]
MTBQT2
0xC5
MTBQT2[7] MTBQT2[6] MTBQT2[5] MTBQT2[4] MTBQT2[3] MTBQT2[2] MTBQT2[1] MTBQT2[0]
MTBQT1[7] MTBQT1[6] MTBQT1[5] MTBQT1[4] MTBQT1[3] MTBQT1[2] MTBQT1[1] MTBQT1[0]
MTBQT0[7] MTBQT0[6] MTBQT0[5] MTBQT0[4] MTBQT0[3] MTBQT0[2] MTBQT0[1] MTBQT0[0]
MTBQT1
0xC6
MTBQT0
0xC7
Type:
Read/Wri
Software Lock:
Reset Value:
Ye
0
The MTB Queue Threshold registers define the maximum size, in PDU cells, of each he 31 queues. If all 31 queues are being
used, it is recommended that the threshold be left at the default of 4 cells. ess than 31 queues are in use, then the queue threshold
may be raised according to Section 9.1 SINGLE BRIDGE MTB CONURON.
•
•
•
•
•
MTBQT30[7:0] Maximum number of PDU cells for queue 30.
MTBQT29[7:0] Maximum number of PDU cells for queue 29.
...................
MTBQT1[7:0] Maximum number of PDU cells for queue 1.
MTBQT0[7:0] Maximum number of PDU cells for queu
18.65 MTB QUEUE FULL—0xC8 to 0xCB MTBQFL0
TBLE 8FL3–MTBQFL0
7
6
5
4
3
2
1
0
MTBQFL3
0xC8
MTBQFL3[7] MTBQFL3[6] MTL3[5] MTBQFL3[4] MTBQFL3[3] MTBQFL3[2] MTBQFL3[1] MTBQFL3[0]
MTBQFL2[7] MTBQFLL2[5] MTBQFL2[4] MTBQFL2[3] MTBQFL2[2] MTBQFL2[1] MTBQFL2[0]
MTBQFL1[7] MTBQFL1[6] FL1[5] MTBQFL1[4] MTBQFL1[3] MTBQFL1[2] MTBQFL1[1] MTBQFL1[0]
MTBQFL0[7] MTBQFL0[5] MTBQFL0[4] MTBQFL0[3] MTBQFL0[2] MTBQFL0[1] MTBQFL0[0]
MTBQT29
0xC9
MTBQFL1
0xCA
MTBQFL0
0xCB
Type:
Read only
Software Lock:
Reset Value:
No
0x00
The MTBQFL3, MTBQFL2, MTBQFL1 and MTBQFL0 registers show which queues are full.
•
MTBQFL3[7] MTBQFL3[7] bit indicates that the entire MTB is full. As memory resources are over assigned among the 31
individual queues then the MTB may be full while some of the individual queues may not be full. When this bit is set, then the
entire queue is full and when clear, the queue is not full.
•
MTBQFL3–MTBQFL0 MTBQFL3[6] corresponds to queue 31 and MTBQFL0[0] corresponds to queue 0. When a bit is set,
then the queue is full and when clear, the queue is not full.
65
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.66 MTB QUEUE EMPTY—0xCC to 0xCF MTBQE3 to MTBQE0
TABLE 86. MTBQE3–MTBQE0
7
6
5
4
3
2
1
0
MTBQE3
0xCC
Reserved
MTBQE3[6] MTBQE3[5] MTBQE3[4] MTBQE3[3] MTBQE3[2] MTBQE3[1] MTBQE3[0]
MTBQT29
0xCD
MTBQE2[7] MTBQE2[6] MTBQE2[5] MTBQE2[4] MTBQE2[3] MTBQE2[2] MTBQE2[1] MTBQE2[0]
MTBQE1[7] MTBQE1[6] MTBQE1[5] MTBQE1[4] MTBQE1[3] MTBQE1[2] MTBQE1[1] MTBQE1[0]
MTBQE0[7] MTBQE0[6] MTBQE0[5] MTBQE0[4] MTBQE0[3] MTBQE0[2] MTBQE0[1] MTBQE0[0]
MTBQE1
0xCE
MTBQE0
0xCF
Type:
Read only
Software Lock:
Reset Value:
No
0xFF, except MTBQE3 = 0x7F
The MTBQE3, MTBQE2, MTBQE1 and MTBQE0 registers show which queues ae em
•
MTBQE3–MTBQE0 MTBQE3[6] corresponds to queue 31 and MTBQE0[0responds to ueue 0. When a bit is set, then the
queue is empty and when clear, the queue is not empty.
18.67 MTB QUEUE FLUSH—0xD0 to 0xD3 MTBQF3 to MTBQF0
TABLE 87. MTBQF3F0
7
6
5
4
2
1
0
MTBQF3
0xD0
Reserved
MTBQF3[6] MTBQF3[5] MT3[4] MTBQF3[3] MTBQF3[2] MTBQF3[1] MTBQF3[0]
MTBQF2
0xD1
MTBQF2[7] MTBQF2[6] MTBQF2[5] F2[4] MTBQF2[3] MTBQF2[2] MTBQF2[1] MTBQF2[0]
MTBQF1[7] MTBQF1[6] MTBQF1[4] MTBQF1[3] MTBQF1[2] MTBQF1[1] MTBQF1[0]
MTBQF0[7] MTBQF0[6] MQF0[5] MTBQF0[4] MTBQF0[3] MTBQF0[2] MTBQF0[1] MTBQF0[0]
MTBQF1
0xD2
MTBQF0
0xD3
Type:
Read/Write
Software Lock:
Reset Value:
Yes
0x00
The MTBQF3, MTBQF2, MTBMTB0 registers allow each of the queues to be flushed. Flushing a queue removes all
PDU cells from the queue. Tr sets the appropriate bit in the MTBQF register to flush a queue. When this has been
completed, the hardware wiSo after setting a bit to flush a queue, the processor should poll the MTBQF register to
determine when the flushing mpleted.
•
MTBQF3–MTBQF0 MTBQF3[6] corresponds to queue 31 and MTBQF0[0] corresponds to queue 0. When a bit is set, then a
flush of the corresponding queue is initiated and when the queue flush is completed and the queue is now in normal operation.
18.68 MTB CELL FLUSH—0xD4 to 0xD7 MTBCF3 to MTBCF0
TABLE 88. MTBCF3–MTBCF0
7
6
5
4
3
2
1
0
MTBCF3
0xD4
Reserved
MTBCF3[6] MTBCF3[5] MTBCF3[4] MTBCF3[3] MTBCF3[2] MTBCF3[1] MTBCF3[0]
MTBCF2
0xD5
MTBCF2[7] MTBCF2[6] MTBCF2[5] MTBCF2[4] MTBCF2[3] MTBCF2[2] MTBCF2[1] MTBCF2[0]
MTBCF1[7] MTBCF1[6] MTBCF1[5] MTBCF1[4] MTBCF1[3] MTBCF1[2] MTBCF1[1] MTBCF1[0]
MTBCF0[7] MTBCF0[6] MTBCF0[5] MTBCF0[4] MTBCF0[3] MTBCF0[2] MTBCF0[1] MTBCF0[0]
MTBCF1
0xD6
MTBCF0
0xD7
www.national.com
66
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Type:
Software Lock:
Reset Value:
Read/Write
Yes
0x00
The MTBCF3, MTBCF2, MTBCF1 and MTBCF0 registers allow the PDU cell at the head of each of the queues to be flushed. This
removes the PDU cell from the head of the queue without corrupting the queue. The processor sets the appropriate bit in the
MTBCF register to flush a cell from a queue. When this has been completed, the hardware will clear the bit. So after setting a bit
to flush a cell from a queue, the processor should poll the MTBCF register to determine when the flush has been completed.
•
MTBCF3–MTBCF0 MTBCF3[6] corresponds to queue 31 and MTBCF0[0] corresponds to queue 0. When a bit is set, then a
flush of the PDU cell at the head of the queue is initiated and when clear, the cell flush is completed and the queue is now in
normal operation.
18.69 QUEUE FLUSH—0xD8 QFL
TABLE 89. QFL
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
Reserved
Resed
FIBFL
MTBFL
Type:
Software Lock:
Reset Value:
ReWrite
0x00
The Queue Flush register allows both the MTB and the FIB queues te completely flushed. This removes all PDU cells from
either the MTB or FIB queue. The processor sets the appropriate bthFL register to flush a queue. When this has been
completed, the hardware will clear the bit. So after setting a bit to flusueuhe processor should poll the QFL register to
determine when the flush has been completed.
•
•
FIBFL When set, then a flush of the FIB queue is initiated when clear, the FIB queue flush is completed and the queue is
now in normal operation.
MTBFL When set, then a flush of the MTB queue is initand wclear, the MTB queue flush is completed and the queue
is now in normal operation.
18.70 MTB QUEUE OVERFLOW—0xD9 to 0xDC MTTBQOV0
BLE 90. MTBQOV3–MTBQOV0
7
6
4
3
2
1
0
MTBQOV3
0xD9
Reserved MTBQOV3[6TBQOV3[MTBQOV3[4] MTBQOV3[3] MTBQOV3[2] MTBQOV3[1] MTBQOV3[0]
MTBQOV2[7] MTBQOV2[5] MTBQOV2[4] MTBQOV2[3] MTBQOV2[2] MTBQOV2[1] MTBQOV2[0]
MTBQOV1[7] M6] MTQOV1[5] MTBQOV1[4] MTBQOV1[3] MTBQOV1[2] MTBQOV1[1] MTBQOV1[0]
MTBQOV0[7] MTBQOV0[5] MTBQOV0[4] MTBQOV0[3] MTBQOV0[2] MTBQOV0[1] MTBQOV0[0]
MTBQT29
0xDA
MTBQOV1
0xDB
MTBQOV0
0xDC
Type:
Read only/Clear on Read
Software Lock:
Reset Value:
No
0x00
The MTBQOV3, MTBQOV2, MTBQOV1 and MTBQOV0 registers indicate the overflow status of the thirty-one queues in the MTB.
If a queue has filled to its threshold defined in the MTBQT31–MTBQT0 registers, and an attempt is made to write another cell to
the queue, then the overflow bit for that queue will be set in these registers. These bits reflect that an attempt has been made to
write to an already full queue and may be used as an indication of problems with the Flow Control mechanism. Up to seven additional
cells will be accepted into the queue before a hard overflow occurs. Once the threshold value plus seven cells has been exceeded
any additional cells will be rejected and discarded automatically. A subsequent read of a cell from the specific queue out over the
Utopia interface will be successful, and will clear the overflow bit in this register once the number of cells in the queue is below the
threshold. If any bit in the MTBQOV3–MTBQOV0 registers is set then the MTBSOVA bit of the UAA register will be set and may
raise an interrupt.
•
MTBQOV3–MTBQOV0 MTBQOV3[6] corresponds to queue 31 and MTBQOV0[0] corresponds to queue 0. When a bit is set,
then there was an attempt to overflow the corresponding queue.
67
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.71 ATM DOWN2UP LOOPBACK CELL COUNT—0xE0 D2ULBCC
TABLE 91. D2ULBCC
7
6
5
4
3
2
1
0
D2ULBCC D2ULBCC D2ULBCC D2ULBCC D2ULBCC D2ULBCC D2ULBCC D2ULBCC
[7] [6] [5] [4] [3] [2] [1] [0]
Type:
Read only/Clear on Read
Software Lock:
Reset Value:
No
0x00
The ATM Down2Up Loopback Cell Count register counts the number of outgoing loopback cells detected on the UTOPIA interface
when Down2Up loopback is enabled with the D2ULB bit of the ALBC register, see Section 18.18 ATM AND LVDS LOOPBACK
CONTROL—0x1A ALBC. Note that this counter is only incremented when a loopback cell is read out of the device.
•
D2ULBCC[7:0] Down2Up Loopback Cell Count value. This register will not roll-over from 0x00 to 0xFF but will stick at 0xFF.
18.72 UTOPIA AND ATM ALARMS—0xE1 UAA
TABLE 92. UAA
7
6
5
4
3
2
1
0
PDULA
CTFRA
D2ULBC
U2DLBC
UPRTY
FIB
MTBSOVA MTBHOVA
Type:
Read only/Clear ea
Software Lock:
Reset Value:
No
0x00
The UTOPIA and ATM Alarms register monitors the UTOPIA iace, loobacks and queue overflows. When set these bits will
raise an interrupt if the corresponding interrupt enables are set.
•
•
PDULA PDU Length Alarm bit. Set = PDU length ay the DUCFG register is greater than the maximum PDU cell
length of 64 bytes. Clear = PDU length is less than aximum of 64 bytes.
CTFRA Cell Transfer Alarm bit. This alarm is only device is configured as a PHY layer by setting the UMODE
bit of the UCFG register. It indicates that the controlyer device has caused an incorrect cell transfer to or from the
DS92UT16. An incorrect cell transfer can onoccur when suspended cell transfer is restarted with an different MPhy address
than initially selected. Set = Incorrect cell nsfer occurred on the UTOPIA transmit or receive interface.
•
•
•
•
•
D2ULBC Set = D2ULBCC count register hngealue.
U2DLBC Set = RAU2DLBC or RBU2DBC count reters have changed value.
UPRTY Set = A parity error has ocon an incming ATM cell byte.
FIBOV Set = FIB queue attemptEquivalent functionality as the MTBQOV3–0 register bits).
MTBSOV MTB Soft Overflow Alarm ne or more of the bits in the MTBQOV3–MTBQOV0 registers are set. Clear =
The MTBQOV3–MTBQOV0 risters arr.
•
MTBHOV MTB Hard Ovebit. Set = MTB queue has attempted to overflow. This is a hard overflow as the overall
MTB has attempted to filard limit of 159 cells.
18.73 UTOPIA AND ATM INTENABLES—0xE2 UAIE
TABLE 93. UAIE
7
6
5
4
3
2
1
0
PDULIE
CTFRIE
D2ULBCIE U2DLBCIE UPRTYIE
FIBOVIE MTBSOVAI MTBHOVIE
E
Type:
Read/Write
Software Lock:
Reset Value:
No
0x00
This register contains the interrupt enables for the alarms in the UAA register. Set = interrupt enabled and Clear = interrupt disabled.
www.national.com
68
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
18.74 ATM LOOPBACK CELL FILTER—0xF7 to 0xFA ALFLT3 to AFLT0
TABLE 94. ALFLT3–ALFLT0
7
6
5
4
3
2
1
0
ALFLT3 0xF7 ALFLT3[7]
ALFLT2 0xF8 ALFLT2[7]
ALFLT1 0xF9 ALFLT1[7]
ALFLT3[6]
ALFLT2[6]
ALFLT1[6]
ALFLT0[6]
ALFLT3[5]
ALFLT2[5]
ALFLT1[5]
ALFLT0[5]
ALFLT3[4]
ALFLT2[4]
ALFLT1[4]
ALFLT0[4]
ALFLT3[3]
ALFLT2[3]
ALFLT1[3]
ALFLT0[3]
ALFLT3[2]
ALFLT2[2]
ALFLT1[2]
ALFLT0[2]
ALFLT3[1]
ALFLT2[1]
ALFLT1[1]
ALFLT0[1]
ALFLT3[0]
ALFLT2[0]
ALFLT1[0]
ALFLT0[0]
ALFLT0
0xFA
ALFLT0[7]
Type:
Software Lock:
Reset Value:
Read/Write
No
0xFF
The ALBCF3, ALBCF2, ALBCF1 and ALBCF0 registers (See Section 7.20) define the ell header bytes filter for detecting ATM
loopback cells. Incoming ATM cells are compared against the loopback cell header foat defined in the ALBCF3–ALBCF0 reg-
isters to determine if they are loopback cells. The filter defined in the ALFLT3–ALFregers is used to determine which bits
of the four byte cell header are compared. If a bit is set then that bit in the incoming adecompared against the corre-
sponding bit in the ALBCF3–ALBCF0 registers. Only those bits which are set in e ALFFLT0 registers are compared to
determine if a cell is a loopback cell.
•
•
•
•
ALBCF3[7:0] Loopback Cell header byte H1 filter.
ALBCF2[7:0] Loopback Cell header byte H2 filter.
ALBCF1[7:0] Loopback Cell header byte H3 filter.
ALBCF0[7:0] Loopback Cell header byte H4 filter.
used ture the device for scan testing, RAM BIST and
Boundary can. The Instruction Register is shown in Figure
23. Bit12–18 are not used. A more detailed description of
oration of the TAP controller can be found in the LOG-
ICION document: Adding Logic Test—A Hardware Ref-
erence July 2000. (NOTE: The Internal SCAN and RAM BIST
functions are not user accessible. Therefore, the device user
should never assert the Test_se pin.)
19.0 Test Features
19.1 TEST STRUCTURES
The DS92UT16 device has the following test structures in
place.
•
•
•
Internal SCAN (manufacturing test only)
RAM BIST (manufacturing test only)
Boundary SCAN
As shown, the device has a AP controller whwas gener-
ated using the LOGICVISION tool suite. This cis
20031622
FIGURE 23. LOGICVISION TAP Instruction Register
The TAP controller contains a device ID register which holds
the device identification. Figure 24 shows the makeup of the
device ID register and the device ID value for the DS92UT16
device.
20031623
DEVICE ID = 0FC2801F
FIGURE 24. Device Identification Register
69
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
19.2 BOUNDARY SCAN
No.
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
1
2
6
64
65
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
Pin Name
U_TXDATA_11
U_TXDATA_10
U_TXDATA_9
U_TXDATA_8
U_TXDATA_7
U_TXDATA_6
U_TXDATA_5
U_TXDATA_4
U_TXDATA_3
U_TXDATA_2
U_TXDATA_1
U_TXDATA_0
UXPARITY
_TXAV_6
UCLA5
U_TXV_4
U_TXCLAV_3
XCLAV_2
U_TXCLAV_1
U_TXCLAV_0
U_TXCLAV_L_TRI
U_TXCLAV_L
U_TXENB_6
Type
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
INPUT
INPUT
INPUT
INPUT
INPUT
INPUT
INPUT
Ctrl.
38
The DS92UT16 device contains boundary scan (BS) cells on
all inputs, outputs, bi-directs, and direction control signals.
There are no boundary scan cells on any of the inputs or out-
puts from the pins to the LVDS Interface block. The boundary
scan order is shown in Table 95 along with the type and con-
trolling BS cell for bidirectional BS cells.For bidirectional pins,
if the controlling cell is a logic ‘1’ then they are outputs.
38
38
38
38
38
TABLE 95.
38
No.
1
Pin Name
RBPWDN
Type
Ctrl.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
38
INPUT
INPUT
INPUT
INPUT
INPUT
INPUT
INPUT
INPUT
INPUT
INPUT
38
2
TXADEN
38
3
TXBDEN
38
4
TPWDN
38
5
TXSYNC
38
6
TXCLK
N/A
N/A
N/A
N/A
N/A
N/A
N/A
7
CPU_BUSMODE
CPU_CS_N
CPU_RD_N
CPU_WR_N
CPU_INT_N
CPU_DATA_TRI
CPU_DATA_7
CPU_DATA_6
CPU_DATA_5
CPU_DATA_4
CPU_DATA_3
CPU_DATA_2
CPU_DATA_1
CPU_DATA_0
CPU_ADDR_7
CPU_ADDR_6
CPU_ADDR_5
CPU_ADDR_4
CPU_ADDR_3
CPU_ADDR_2
CPU_ADDR
CPU_ADD
GPIO_TRI_
GPIO_3
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
OUTPUT N/A
ENABLE N/A
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDI
INT
INP
PUT
I
INPUT
INPUT
12
12
ENABLE N/A
BIDIR 63
12
OUTPUT N/A
OUTPUT N/A
OUTPUT N/A
OUTPUT N/A
OUTPUT N/A
OUTPUT N/A
OUTPUT N/A
12
U_TXENB_5
1
U_TXENB_4
U_TXENB_3
U_TXENB_2
12
U_TXENB_1
N/
N/A
N/A
N/A
N/A
N/A
U_TXENB_0
UDB_CLK
INPUT
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
N/A
38
38
38
38
38
38
38
U_TXENB_L
U_TXSOC
U_TXADDR_4
U_TXADDR_3
U_TXADDR_2
U_TXADDR_1
U_TXADDR_0
U_RXDATA_TRI
U_RXDATA_15
U_RXDATA_14
U_RXDATA_13
U_RXDATA_12
U_RXDATA_11
U_RXDATA_10
U_RXDATA_9
U_RXDATA_8
U_RXDATA_7
U_RXDATA_6
U_RXDATA_5
U_RXDATA_4
ENABLE N/A
BIDIR 29
ENABLE N/A
BIDIR 31
ENABLE N/A
BIDIR 33
ENABLE N/A
ENABLE N/A
GPIO_TRI_2
GPIO_2
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
80
80
80
80
80
80
80
80
80
80
80
80
GPIO_TRI_1
GPIO_1
GPIO_TRI_0
GPIO_0
BIDIR
35
RESET_N
INPUT
N/A
UTFC_MODE
U_TXDATA_15
U_TXDATA_14
U_TXDATA_13
U_TXDATA_12
ENABLE N/A
BIDIR
BIDIR
BIDIR
BIDIR
38
38
38
38
www.national.com
70
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
No.
93
Pin Name
U_RXDATA_3
U_RXDATA_2
U_RXDATA_1
U_RXDATA_0
U_RXOSC
Type
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
Ctrl.
80
No.
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
Pin Name
U_RXCLAV_U_4
U_RXCLAV_U_3
U_RXCLAV_U_2
U_RXCLAV_U_1
U_RXCLAV_U_0
U_RXCLAV_L_TRI
U_RXCLAV_L
U_RXPARITY
U_RXADDR_4
U_RXADDR_3
U_RXADDR_2
U_RXADDR_1
UXADDR_0
TE_SE
Type
Ctrl.
N/A
N/A
N/A
N/A
N/A
INPUT
INPUT
INPUT
INPUT
INPUT
94
80
95
80
96
80
97
80
98
U_RXENB_U_6
U_RXENB_U_5
U_RXENB_U_4
UUB_CLK
OUTPUT N/A
OUTPUT N/A
OUTPUT N/A
ENABLE N/A
99
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
BIDIR
INPUT
INPUT
114
80
100
101
102
103
104
105
106
107
108
INPUT
N/A
38
U_RXENB_U_3
U_RXENB_U_2
U_RXENB_U_1
U_RXENB_U_0
U_RXENB_L
OUTPUT N/A
OUTPUT N/A
OUTPUT N/A
OUTPUT N/A
38
38
38
38
BIDIR
INPUT
INPUT
38
N/A
N/A
U_RXCLAV_U_6
U_RXCLAV_U_5
N/A
N/A
WD
71
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
20.0 Package
196-ball LBGA. Dimensions 15 x 15 x 1.37 mm, 1.0 mm ball pitch.
TABLE 96. Pin Locations—BGA196 Package
Signal Type Description
Ball
Pin Name
A2
AGND
AGND
AGND
AGND
AGND
AGND
AGND
AGND
AVDD
GND
Analog GND for LVDS I/O
Analog GND for LVDS I/O
Analog GND for LVDS I/O
Analog GND for LVDS I/O
Analog GND for LVDS I/O
Analog GND for LVDS I/O
Analog GND for LVDS I/O
Analog GND for LVDS I/O
Analog VDD for LVDS I/O
Analog VDD for LVDS I/O
Analog VDD for LVDS
Analog VDD for LV
Analog VDD for LVDS I/O
Analog VDD fLVDS I/O
Address Bu
A12
B11
B13
C4
C7
C13
E7
B3
B4
B12
B14
C10
D7
J2
GND
GND
GND
GND
GND
GND
GND
3.3V
AVDD
3.3V
AVDD
3.3V
AVDD
3.3V
AVDD
3.3V
AVDD
3.3V
CPU_Addr[0]
CPU_Addr[1]
CPU_Addr[2]
CPU_Addr[3]
CPU_Addr[4]
CPU_Addr[5]
CPU_Addr[6]
CPU_Addr[7]
CPU_BusMode
CPU_cs
Input LVTTL
Input LVTTL
Input LVTTL
Input LVTTL
Input LVTTL
Input LVTTL
Input LVTTL
Input LVTTL
Input LV
Input LVL
BiDir LVTTL
BTTL
Bi
iDir LL
LVTTL
LVTTL
ir LVTTL
Output LVTTL
Input LVTTL
Input LVTTL
GND
J3
Address Bus
J1
Addrss Bus
H2
H1
G1
F1
Addreus
Address B
Bus
us
E1
E6
E5
J4
Bus
Mode Select for CPU Bus Protocol
elect Signal to Validate the Address Bus for R/W Transfers
CPU_Data[0]
CPU_Data[1]
CPU_Data[2]
CPU_Data[3]
CPU_Data[4]
CPU_Data[5]
CPU_Data[6]
CPU_Data[7]
CPU_int
ata Bus
H3
F2
Data Bus
Data Bus
H4
F3
Data Bus
Data Bus
G3
G4
E2
F4
Data Bus
Data Bus
Data Bus
Interrupt Request Line
E3
F5
CPU_rd (CPU_ds)
CPU_wr (CPU_rnw)
DGND
Read or Data Strobe, Depending on CPU_BusMode
Write or Read/Write, Depending on CPU_BusMode
B7
C2
D11
E11
F6
Digital GND
Digital GND
Digital GND
Digital GND
Digital GND
Digital GND
Digital GND
Digital GND
Digital GND
Digital GND
DGND
GND
DGND
GND
DGND
GND
DGND
GND
F9
DGND
GND
G5
H7
H8
H9
DGND
GND
DGND
GND
DGND
GND
DGND
GND
www.national.com
72
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Ball
K14
Pin Name
Signal Type
GND
Description
DGND
Digital GND
Digital GND
Digital GND
VDD for Core Logic
VDD for Core Logic
VDD for Core Logic
Digital VDD
L1
DGND
GND
N8
DGND
GND
K1
DVDD25
DVDD25
DVDD25
DVDD33
DVDD33
DVDD33
DVDD33
DVDD33
DVDD33
DVDD33
DVDD33
DVDD33
DVDD33
DVDD33
2.5V
K13
P10
A1
2.5V
2.5V
3.3V
A11
D10
F7
3.3V
Digital VDD
3.3V
Digital VDD
3.3V
Digital VDD
F8
3.3V
Digital VDD
G2
G6
G7
G14
J7
3.3V
Digital VDD
3.3V
Digital VDD
3.3V
Digital VDD
3.3V
Digital VDD
3.3V
Digital VDD
J11
H6
3.3V
Digital VDD
GPIO [0]
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
Input LVTTL
Input LVTTL
Input LVTTL
Output LVTTL
Input LVTTL
Input LVT
Diff. Inp
Diff. Input
Diput
O
Input L
t LVTTL
ut LVTTL
ut LVTTL
Diff. Input
Diff. Input
Diff. Output
Diff. Output
Output LVTTL
Input LVTTL
Input LVTTL
Output LVTTL
Input LVTTL
Input LVTTL
Input LVTTL
General Purpe Input and Output
General Puse ut and Output
General Purpoput d Output
General Purpose Inand Output
BouScan Tst Clock
H5
GPIO [1]
K2
GPIO [2]
J6
GPIO [3]
E9
JTAG_CLK
E8
JTAG_Reset
JTAG_TDI
Boundary est Circuit Reset
y ScaTest Data In
Scan Test Data Out
Scan Test Mode Select
DEnable for Transmit A
nput for Receiver Port A
F12
E13
E10
C1
JTAG_TDO
JTAG_TMS
LVDS_ADen
LVDS_ADin[−]
LVDS_ADin[+]
LVDS_ADout[−]
LVDS_ADout[+]
LVDS_ALock_n
LVDS_APwdn
LVDS_ARefClk
LVDS_ARxClk
LVDS_BDen
LVDS_BDin[−]
LVDS_BDin[+]
LVDS_BDout[−]
LVDS_BDout[+]
LVDS_BLock_n
LVDS_BPwdn
LVDS_BRefClk
LVDS_BRxClk
LVDS_Synch
LVDS_TxClk
LVDS_TxPwdn
NC
A14
A13
A9
put for Receiver Port A
Output for Driver A
A10
C14
E14
B10
D14
D2
Output for Driver A
Lock Signal from Receive Port A
Receive Port A and Deserializer Power Down
Reference Clock for Receiver A PLL
Recovered Clock Output from Receive Port A
Driver Enable for Transmit B
Input for Receive Port B
A3
A4
Input for Receive Port B
A6
Output for Driver B
A7
Output for Driver B
C3
Lock Signal from Receive Port B
Receive Port B and Deserializer Power Down
Reference Clock for Receiver B PLL
Recovered Clock Output from Receive Port B
Force SYNC patterns on Transmit A and B
Reference Clock for Driving Transmission Function
Powerdown for LVDS Serializer
NO CONNECT
B1
D4
B2
E4
D1
D3
G8
J8
NC
NO CONNECT
73
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Ball
Pin Name
Signal Type
GND
Description
K8
B8
C8
D8
C9
NC
NO CONNECT
GND for Transmit PLL
GND for Transmit PLL
GND for Transmit PLL
GND for PLL A
GND for PLL A
GND for PLL A
GND for PLL A
GND for PLL B
GND for PLL B
GND for PLL B
GND for PLL B
Transmit PLL VDD
Transmit PLL VDD
VDD for PLL A
PGND
PGND
PGND
PGNDA
PGNDA
PGNDA
PGNDA
PGNDB
PGNDB
PGNDB
PGNDB
PVDD
GND
GND
GND
C11
C12
G9
GND
GND
GND
B5
GND
B6
GND
C5
GND
C6
GND
A8
3.3V
B9
PVDD
3.3V
D9
PVDDA
PVDDA
PVDDA
PVDDB
PVDDB
PVDDB
3.3V
D12
E12
A5
3.3V
VDD for PLL A
3.3V
VDD for PLL A
3.3V
VDD for PLL B
D5
3.3V
VDD for PLL
D6
3.3V
VDD for PLL
L2
Reset_n
Input LVTTL
Input LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTT
BiDir LVL
Input LV
InpVTTL
T
Inpu
ut LVTTL
LVTTL
LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
Chip Reset Contr
Scanable
D13
F11
F10
F13
G11
G12
H11
G13
H12
F14
H13
H14
J13
J14
N13
N14
P14
L11
P13
M12
P12
K10
N12
P11
N11
M11
M10
J10
Test_se
U_RxAddr[0]
U_RxAddr[1]
U_RxAddr[2]
U_RxAddr[3]
U_RxAddr[4]
U_RxCLAV [0]
U_RxCLAV [1]
U_RxCLAV [2]
U_RxCLAV [3]
U_RxCLAV [4]
U_RxCLAV [5]
U_RxCLAV [6]
U_RxCLAV [7]
U_RxData [0]
U_RxData [1]
U_RxData [2]
U_RxData [3]
U_RxData [4]
U_RxData [5]
U_RxData [6]
U_RxData [7]
U_RxData [8]
U_RxData [9]
U_RxData [10]
U_R xData [11]
U_RxData [12]
U_RxData [13]
Address PDevice Being Polled or Selected
s of MY Device Being Polled or Selected
f MPHY Device Being Polled or Selected
f MPHY Device Being Polled or Selected
of MPHY Device Being Polled or Selected
Receive Cell Available—Normal/Extended PHY Port Control
eceive Cell Available—Normal/Extended PHY Port Control
Receive Cell Available—Normal/Extended PHY Port Control
Receive Cell Available—Normal/Extended PHY Port Control
Receive Cell Available—Extended PHY Port Control
Receive Cell Available—Extended PHY Port Control
Receive Cell Available—Extended PHY Port Control
Receive Cell Available—Extended PHY Port Control
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
www.national.com
74
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Ball
Pin Name
U_RxData [14]
Signal Type
BiDir LVTTL
Description
K9
L9
Receive Data Bus, from the PHY Layer Device(s)
Receive Data Bus, from the PHY Layer Device(s)
Enable Data Transfers—Normal/Extended PHY Port Control
Enable Data Transfers—Extended PHY Port Control
Enable Data Transfers—Extended PHY Port Control
Enable Data Transfers—Extended PHY Port Control
Enable Data Transfers—Extended PHY Port Control
Enable Data Transfers—Extended PHY Port Control
Enable Data Transfers—Extended PHY Port Control
Enable Data Transfers—Extended PHY Port Control
Receive Data Bus Parity Bit
U_RxData [15]
U_RxENB [0]
U_RxENB [1]
U_RxENB [2]
U_RxENB [3]
U_RxENB [4]
U_RxENB [5]
U_RxENB [6]
U_RxENB [7]
U_RxParity
BiDir LVTTL
BiDir LVTTL
Output LVTTL
Output LVTTL
Output LVTTL
Output LVTTL
Output LVTTL
Output LVTTL
Output LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
Bidir LVTTL
Input LVTTL
Input LVTTL
Input LVTTL
Input LVTTL
Input LVTTL
Input LVTTL
Input LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVT
BiDir LVL
BiDir LVTTL
BTTL
Bi
iDir LL
LVTTL
LVTTL
ir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
BiDir LVTTL
Output LVTTL
Output LVTTL
Output LVTTL
Output LVTTL
Output LVTTL
Output LVTTL
Output LVTTL
BiDir LVTTL
J12
L14
M14
L13
G10
J9
K11
L12
H10
M13
L10
N10
M9
L8
U_RxSOC
Receive Start of Cell
U_TxAddr[0]
U_TxAddr[1]
U_TxAddr[2]
U_TxAddr[3]
U_TxAddr[4]
U_TxCLAV [0]
U_TxCLAV [1]
U_TxCLAV [2]
U_TxCLAV [3]
U_TxCLAV [4]
U_TxCLAV [5]
U_TxCLAV [6]
U_TxCLAV [7]
U_TxData [0]
U_TxData [1]
U_TxData [2]
U_TxData [3]
U_TxData [4]
U_TxData [5]
U_TxData [6]
U_TxData [7]
U_TxData [8]
U_TxData [9]
U_TxData [10]
U_TxData [11]
U_TxData [12]
U_TxData [13]
U_TxData [14]
U_TxData [15]
U_TxENB [0]
U_TxENB [1]
U_TxENB [2]
U_TxENB [3]
U_TxENB [4]
U_TxENB [5]
U_TxENB [6]
U_TxENB [7]
U_TxParity
Address of MPHY Device BePolled or Selected
Address of MPHY Device ng led or Selected
Address of MPHY Device Beoller Selected
Address of MPHY De Being Por Selected
Address of MPHY Being Polled or Selected
Utopia Transmit Cell Availa—Normal/Extended PHY Control
Utopia TransCell Available—Normal/Extended PHY Control
Utopia Trat l Avalable—Normal/Extended PHY Control
Utopia Transmit Ailable—Normal/Extended PHY Control
Utopa Transmit Cell vailable—Extended PHY Port Control
Utopinsmit ll Available—Extended PHY Port Control
Utopia TraCell Available—Extended PHY Port Control
ansmit Cell Available—Extended PHY Port Control
ata Bus, toward the PHY Layer Device(s)
Data Bus, toward the PHY Layer Device(s)
Transmit Data Bus, toward the PHY Layer Device(s)
ransmit Data Bus, toward the PHY Layer Device(s)
ransmit Data Bus, toward the PHY Layer Device(s)
Transmit Data Bus, toward the PHY Layer Device(s)
Transmit Data Bus, toward the PHY Layer Device(s)
Transmit Data Bus, toward the PHY Layer Device(s)
Transmit Data Bus, toward the PHY Layer Device(s)
Transmit Data Bus, toward the PHY Layer Device(s)
Transmit Data Bus, toward the PHY Layer Device(s)
Transmit Data Bus, toward the PHY Layer Device(s)
Transmit Data Bus, toward the PHY Layer Device(s)
Transmit Data Bus, toward the PHY Layer Device(s)
Transmit Data Bus, toward the PHY Layer Device(s)
Transmit Data Bus, toward the PHY Layer Device(s)
Utopia Enable Data Transfers—Normal/Extended PHY Control
Utopia Enable Data Transfers—Extended PHY Control
Utopia Enable Data Transfers—Extended PHY Control
Utopia Enable Data Transfers—Extended PHY Control
Utopia Enable Data Transfers—Extended PHY Control
Utopia Enable Data Transfers—Extended PHY Control
Utopia Enable Data Transfers—Extended PHY Control
Utopia Enable Data Transfers—Extended PHY Control
Utopia Transmit Data Bus Parity Bit
N9
M6
P4
N6
K7
K6
L5
K5
N5
M5
P3
N4
P2
M4
L4
N3
P1
M3
M2
N2
N1
M1
L3
K4
K3
P9
P7
P6
P5
N7
L7
M7
L6
J5
75
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
Ball
Pin Name
U_TxSOC
Signal Type
BiDir LVTTL
Description
M8
P8
Transmit Start of Cell
U_UDBClk
U_UUBClk
Input LVTTL
Input LVTTL
Utopia Down Bridge Clock Input
Utopia Up-Bridge Clock Input
K12
3. The ATM Forum User-Network Interface Specification,
21.0 References
1. The ATM Forum UTOPIA Level 2, Version 1.0
Specification, af-phy-0039.000, June 1995
Version 3.1, Sept. 1994.
4. IEEE 1149.1 Standard–JTAG.
2. ITU-T I.432.1, B-ISDN User Network Interface–Physical
Layer Specification: General Characteristics, August
1996.
www.national.com
76
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Package Derating
ESD Rating LVDS I/O
ESD Rating CMOS I/O
28.6 mW/°C
>3 kV HBM
>2 kV HBM
22.0 Absolute Maximum Ratings (Note
13)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
23.0 Recommended Operating
Conditions
Supply Voltage I/O (VCCIO
)
−0.3V to 4V
−0.3V to 3.2V
−0.3V to 3.6V
−0.3V to (VCC +0.3V)
−0.3V to 3.6V
Continuous
Min Nom Max Units
Supply Voltage Core Internal (VCCINT
CMOS/TTL Input and I/O Voltage
CMOS/TTL Output Voltage
LVDS DO/RIN Voltage
LVDS Output Short Circuit Duration
Junction Temperature
)
Supply Voltage 3.3V
Supply Voltage 2.5V
3.0
2.37
3.3
2.5
3.6
2.63
V
V
Operating Free
Temperature
−40
+25
+85
°C
CMOS/TTL Input and I/O
Voltage
LVDS Input/Output Voltage
+150°C
0
0
-
-
+3.6
+3.3
V
V
Storage Temperature
−65°C to +125°C
Lead Temperature (soldering, 10
seconds)
Max. Package Power Dissipation
Capacity
+225°C
3.5 W
24.0 Electrical Characteristics
CMOS DC Specifications
Microprocessor Pins, LVDS Control Pins, nd Clocks
Over recommended operating supply and temperature ranges unless se scified. (Note 14)
Symbol
VIH
Parameter
High Level Input Voltage
Low Level Input Voltage
Input Clamp Voltage
Input Current
Conditions
req.
Min
2
Typ
Max
Units
VCC
0.8
V
V
VIL
VCL
IIN
GND
Inputs
−0.7
±2
−1.5
+10
V
VIN = 0V or 3.6
−10
µA
IINH
Input Current for Pulldown VIN = 0V
pins
80
160
µA
IINL
VOH
VOL
IOS
Input Current for Pullup pins VIN = V
High Level Output Voltage IOH = 6
−90
−160
VCC
0.4
µA
V
2.4
GND
−15
Low Level Output Voltage
I6 mA
V
Outputs
Output Short Circuit Curren
−18
−85
mA
IOZ
TRI-STATE Output Current = 0.8V,
−10
±0.4
+10
µA
VOUor VCC
V
UTOPIA Bus DC ations
Pin types are defined inTable
Over recommended operating supply and temperature ranges unless otherwise specified. (Note 14)
Symbol
VIH
Parameter
High Level Input Voltage
Low Level Input Voltage
Input Clamp Voltage
Input Current
Conditions
Pin/Freq.
Min
2
Typ
Max
VCC
0.8
Units
V
VIL
GND
V
Inputs, BiDir
VCL
IIN
−0.7
±2
−1.5
+10
VCC
0.4
V
VIN = 0V or 3.6V
−10
2.4
µA
V
VOH
VOL
IOS
IOZ
High Level Output Voltage IOH = 8 mA
Low Level Output Voltage IOL = 8 mA
GND
−15
V
Output, BiDir
Output Short Circuit Current VOUT = 0V
−85
mA
TRI-STATE Output Current PD* or REN = 0.8V,
−10
±0.4
+10
µA
VOUT = 0V or VCC
V
77
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
Bus LVDS DC Specifications
Over recommended operating supply and temperature ranges unless otherwise specified. (Note 14)
LVDS Specifications are for LVDS Input and Output pins only. Control inputs and clocks are specified under Control Pin and Clocks
DC Specifications.
Symbol
VTH
Parameter
Conditions
Pin/Freq.
Min
Typ
Max
Units
Differential Threshold High VCM = 1.1V
Voltage
+50
+100
mV
VTL
IIN
Differential Threshold Low
Voltage
−100 mV
−50
mV
LVDS_ADin[+,−]
LVDS_BDin[+,−]
Input Current
VIN = +2.4V, VCC = 3.6V or
−10
−10
350
±5
±5
+10
+10
550
µA
µA
0V
VIN = 0V, VCC = 3.6V or 0V
VOD
Output Differential Voltage
(DO+)–(DO−)
RL = 100Ω
450
mV
DVOD
Output Differential Voltage
Unbalance
2
35
1.3
−70
mV
V
VOS
IOS
Offset Voltage
.9
1.0
−50
LVDS_Aut[+,−]
Output Short Circuit Current DO = 0V, DIN = H, TXPWDN* LVDS_ut[+,−]
and DEN = 2.4V
−35
mA
IOZ
IOX
TRI-STATE Output Current TXPWDN* or DEN = 0.8V,
DO = 0V or VDD
−10
−10
±1
±1
10
10
µA
µA
Power-Off Output Current
VDD = 0V, DO = 0V or 3.6V
Supply Current, VCC = 2.5V
Over recommended operating supply and temperature ranges unothise specified. (Note 14)
Symbol
ICCR
Parameter
Conditio
Pin/Freq.
Min
Typ
Max
Units
Worst Case Supply Current Utopia CL = 15
52 MHz
200
260
mA
LVDS RL = 10
Pattern, VDD =
ICCT
Typical Loading and
Switching
CL = 1F, PRBS7 Data
Patter
33 MHz
112
140
mA
Supply Current, VCC =
Over recommended operating supplure ranges unless otherwise specified. (Note 14)
Symbol
ICCR
Parameter
nditions
Pin/Freq.
Min
Typ
Max
Units
Worst Case Supply topia CL = 15 pF, Bus
52 MHz
270
360
mA
DS RL = 100Ω, Checker
ttern, VDD = 3.6V
ICCT
Typical Loading and
Switching
CL = 15 pF, PRBS7 Data
Pattern
33 MHz
140
165
mA
UTOPIA Bus Switching Characteristics
Over recommended operating supply and temperature ranges unless otherwise specified. (Note 14)
Symbol
tUCP
Parameter
Input Clock Period
Input Clock Duty Cycle
Input Clock Jitter
Conditions
Pin/Freq.
Min
20
Typ
Max
Units
ns
U_UUBClk,
U_UDBClk
tUDC
40
50
1
60
5
%
tUJIT
%
tUSETUP
tUHOLD
Input Data Valid before CLK CL = 30 pF, (Figure 31)
Input Data Valid after CLK CL = 30 pF, (Figure 31)
4
1
ns
Inputs
ns
www.national.com
78
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Symbol
tULH
Parameter
Conditions
Pin/Freq.
Min
Typ
Max
Units
Output Low-to-High
Transition Time
CL = 30 pF, (Figure 31)
1
8
ns
tUHL
Output High-to-Low
Transition Time
CL = 30 pF, (Figure 31)
CL = 30 pF, (Figure 31)
1
4
8
ns
ns
tUROS
Output Data Valid before
CLK
Outputs
tUROH
tUHZR
tULZR
tUZHR
tUZLR
Output Data Valid after CLK CL = 30 pF, (Figure 31)
1
1
1
1
1
ns
ns
ns
ns
ns
High to TRI-STATE Delay
16
16
16
16
Low to TRI-STATE Delay
(Figure 32)
TRI-STATE to High Delay
TRI-STATE to Low Delay
Pin Name
U_TxData[15:0]
U_Tx Parity
ATM Mode
Output
Output
Input
Y Mode
Iut
put
U_Tx CLAV[7:4]
U_TxCLAV[3:0]
U_TxENB[7:1]
U_TxENB[0]
Input
Output
*
Output
Outpu
Ou
Output
Input
Input
Input
Input
Output
Output
*
U_TxSOC
U_TxAddr[4:0]
U_RxData[15:0]
U_Rx Parity
nput
U_Rx CLAV[7:4]
U_RxCLAV[3:0]
U_RxENB[7:1]
U_RxENB[0]
I
Input
Output
*
tput
utput
Input
Input
Output
Input
U_RxSOC
U_RxAddr[4:0]
Output
*The extended addressing pins U_TxCLAV[7:4], U_RxCLAV[7:4], U_NB[7:1], and
U_RxENB[7:1] are defined for ATM mode only.
LVDS Switching Charas
Over recommended operating supply and ature ranges unless otherwise specified. (Note 14)
Symbol
tLLH
Parameter
Conditions
= 100, CL = 10 pF,
gure 25)
Pin/Freq.
Min
Typ
Max
Units
LVDS Low-to-High
Transition Time
300
400
ps
tLHL
LVDS High-to-Low
Transition Time
RL = 100, CL = 10 pF,
(Figure 25 )
300
60
400
150
150
ps
ps
ps
LVDS_ADout[+,−],
LVDS_BDout[+.,−]
tRJIT
tDJIT
tDSR1
Random Jitter of LVDS Tx
Clock
Deterministic Jitter of LVDS
Tx Data
Deserializer PLL Lock Time (Figure 28)
from PWRDN (with
SYNCPAT)
30
12
µs
LVDS_ADin[+,−],
LVDS_BDin[+.,−]
tDRS2
tRNM
Deserializer PLL Lock Time (Figure 29)
from SYNCPAT
µs
ps
Deserializer Noise Margin
(Figure 30)
400
79
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
Timing Requirements for Input Clock
LVDS_TxClk, LVDS_ARefClk, LVDS_BRefClk
Over recommended operating supply and temperature ranges unless otherwise specified. (Note 14)
Symbol
tRFCP
tRFDC
tRFCP/tTCP Ratio of REFCLK to TCLK
Parameter
REFCLK Period
REFCLK Duty Cycle
Conditions
Pin/Freq.
Min
19.2
40
Typ
Max
Units
ns
50
60
5
%
−5
%
tRFTT
tJIT
REFCLK Transition Time
Input Jitter
(Figure 27)
8
ns
Jitter Frequency < 250 kHz
Jitter Frequency < 250 kHz
Jitter Frequency < 250 kHz
15
1.5
0.15
UI
UI
UI
Microprocessor Interface Switching Characteristics
Over recommended operating supply and temperature ranges unless otherwise specid. (Note 14)
Symbol
tLLH
Parameter
Conditions
Pin/Fre
Min
Typ
Max
6
Units
ns
Low-to-High Transition Time CL = 15 pF (Figure 26)
High-to-Low Transition Time CL = 15 pF (Figure 26)
Outs
tLHL
6
ns
tSETUP
tHOLD
See Section 17.0
Microprocessor Interface
Operation
Inputs
Note 13: Absolute Maximum Ratings are those values beyond which the safety of the dennoguaranteed. They are meant to imply that the devices
should be operated at these limits. The table of “Electrical Characteristics” specifies conditioce operation.
Note 14: Typical values are given for VCC = 3.3V and TA = 25°C
Note 15: Current into the device is defined as positive. Current out of device pdefined aegative. Voltages are referenced to ground except VOD, VTH and
VTL which are differential voltages.
Note 16: For the purpose of specifying deserializer PLL performance ttSR2 aecified with the REFCLK running and stable, and specific conditions
of the incoming data stream (SYNCPATs). tDSR1 is the time requirealizer to indicate lock upon power-up or when the power-down mode. tDSR2 is
the time required to indicate lock for the powered-up and enabled dhe input (RI+ and RI−) conditions change from not receiving data to receiving
synchronization patterns (SYNCPATs). The time to lock to random t upon the incoming data.
Note 17: tRNM is a measure of how much phase noise (jitter) the delerate in the incoming data stream before bit errors occur.
www.national.com
80
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
20031628
FIGURE 25. LVDS Rise and Fall times
20031629
FIGURE 26. CMOS Rise and Fts
20031630
FIGURE Transition time
20031634
FIGURE 28. Deserializer lock time tDSR1
81
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
20031635
FIGURE 29. Deserializer lock time SR2
20031636
FIGRE 30. lizer Noise Margin
20031638
RE 31. UTOPIA Setup and Hold Time Definition
20031639
FIGURE 32. UTOPIA TRI-STATE Timing
www.national.com
82
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
TABLE 97. UTOPIA Transmit Timing
Signal Name
DIR
Item
f1
Description
TxClk Frequency (nominal)
TxClk Duty Cycle
Min
0
Max
50 MHz
60%
U_UDBClk, U_UUBClk
A → P
tT2
tT3
tT4
tT5
tT6
40%
—
TxClk Peak-to-Peak Jitter
TxClk Rise/Fall Time
Input Setup to TxClk
5%
2 ns
—
4 ns
U_TxData[15:0],
U_TxPrty, U_TxSOC,
U_TxEnb[7:0],
—
—
A → P
A ← P
Input Hold from TxClk
1 ns
U_TxAddr[4:0]
U_TxClav [7:0]
tT7
tT8
Input Setup to TxClk
4 ns
1 ns
4 ns
0 ns
ns
1 ns
—
—
—
—
—
—
Input Hold from TxClk
tT9
Signal Going Low Impedance to TxClk
Signal Going High Impedance to TxC1)
Signal Going Low Impedance from Tx
Signal Going High Impedance fTxClk
tT10
tT11
tT12
TABLE 98. UTOPIA Receive Timing
Signal Name
DIR
Item
f1
Descripn
RxClk Frequency (no
RxClk Duty Cycle
Min
0
Max
50 MHz
60%
U_UDBClk, U_UUBClk
A → P
tT2
tT3
tT4
tT5
tT6
tT7
tT8
tT9
tT10
tT
40%
—
RxClk Peak-to-eak Jitter
RxClk Rise/Fall T
5%
2 ns
—
U_RxEnb[7:0],
U_RxAddr[4:0]
Input SetuxClk
4 ns
1 ns
4 ns
1 ns
4 ns
0 ns
1 ns
1 ns
—
—
—
—
—
—
—
—
A → P
A ← P
Input Hlk
U_RxData[15:0],
U_RxParity,
U_RxSOC, U_RxClav
[7:0]
Input S
Iut HolxClk
ignal ing Low Impedance to RxClk
al Gg High Impedance to RxClk (2)
Signal ing Low Impedance from RxClk
al Going High Impedance from RxClk
83
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
25.0 Appendix A: Layout and
Connection Guidelines
20031624
FIGURE 33. Block Diagram Is a Top View of 196 LBGA Ball Assignment.
www.national.com
84
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
25.1 POWER CONNECTIONS
Using the minimum manufacturing thickness between the
ground and power planes creates a distributed bypass ca-
pacitance. Due to the potentially high inrush currents caused
by Utopia bus output switching, using traces routed through
the array to connect bypass caps to the balls is not recom-
mended. This is because the inductance of the traces will
negate the affect of the bypass capacitors.
25.1.1 Digital Supplies (DVDD and DGND)
The digital supply pins provide power to the digital section of
the device. Since the digital supplies are subject to switching
noise, the bypass considerations are important. The DVDD
and DGND balls are located mostly in the center of the ball
array. If the PCB stack-up and signal routing allows placing
bypass caps on the bottom of the board close to the digital
supply pins, then an array of capacitors will provide wide band
bypassing. The total bypass capacitance should be at least
0.3 µF.
25.2.2 Analog Supplies (AVDD and AGND)
In general, the analog supply pins can be connected to the
digital power planes. The AGND pins should be connected to
a ground plane that connects them directly to the AGND pins
of the sending device. This provides for minimum ground off-
set between the devices and provides a return path for the
minute return currents from the LVDS receivers.
The 2.5V supply pins are located near the edge of the pack-
age, which is more convenient for placement of bypass ca-
pacitors. If a power plane supplies the 2.5V, then standard
bypass capacitors of 0.1 µF in parallel with 0.01 µF is suffi-
cient. If the PCB traces connect the 2.5V to the part, then
additional bulk decoupling capacitance should account for the
added trace inductance.
25.2.3 PLL Supplies (PVDD and PGND)
The PLL supply pinhould be isolated from the shared digital
and analog poweanes. PVDD and PGND pins are generally
grouped togetho aw them to be connected to a split
plane or to a “copour” the top layer. The split plane
or copper pr is connto the power planes through a PI
filter to blow frequeny noise. High frequency bypassing
should ped on the PLL side of the filter to supply
switching currenhe PLL. A separate filter for each PLL is
recmended. If filters are not desired use a high value (5 µF
t00 ncapacitor connected to the PVDD pins to limit low
fry no.
25.1.2 Analog Supplies (AVDD and AGND)
The analog VDD and GND power the LVDS driver and receiver
section of the device. High frequency bypassing such as
0.001 µF capacitance is required due to the very high data
rates of the LVDS signals. See Figure 34.
25.1.3 PLL Supplies (PVDD and PGND)
The PLL supply pins provide power for the PLL(s) in the cir-
cuit. The most important function of bypassing or filtering for
the PLL inputs is to attenuate low frequency noise from en-
tering the PVDD pins. A common source of low frequency
noise is switching power supplies. Power distribution net-
works should be designed to attenuate any harmonics cre
ed by the switching supply. The addition of a PI filter ne
at the PVDD pins is optional. See Figure 34.
25.2.4 LI/O
The LVDS I/O pins are located on the outer ring of balls so
hey be routed on the surface layer to minimize added
tance. Use surface mount resistors to terminate trans-
mision lines as close to the LVDS inputs as possible. The
LVDS drivers on the DS92UT16 are designed to drive 100Ω
differential lines.
25.2 LAYOUT GUIDELINES
The LVDS A driver outputs (LVDS_Adin[+/−]) are swapped in
position compared to the other LVDS I/O pairs. This allows
them to be “wrapped around ” a connector pin array so that
all of the LVDS signals can be routed on the surface layer.
See Figure 35.
25.2.1 Digital Supplies (DVDD and DGND)
Digital supply connection to bypass capacitors ft,
but the more layers in the PCB the easier it is to place e
capacitors near the device. Therefore, commention
is to use full power planes to distribuhese pins.
85
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
www.national.com
20031625
FIGURE 34. Recommended byng anering for the Analog and PLL power supplies on the DS92UT16 Utopia-LVDS
Bridge.
20031626
FIGURE 35. Diagram shows routing high-speed LVDS lines on one layer to a connector header.
www.national.com
86
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
26.0 Physical Dimensions inches (millimeters) unless otherwise noted
Order Number DS92UT16
See NS Package Number NUJB196
87
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
Notes
For more National Semiconductor product information and proven design tools, visit the following Web sites at:
www.national.com
Products
www.national.com/amplifiers
Design Support
www.national.com/webench
Amplifiers
WEBENCH® Tools
App Notes
Audio
www.national.com/audio
www.national.com/timing
www.national.com/adc
www.national.com/interface
www.national.com/lvds
www.national.com/power
www.national.com/appnotes
www.national.com/refdesigns
www.national.com/samples
www.national.com/evalboards
www.national.com/packaging
www.national.com/quality/green
www.national.com/contacts
www.national.com/quality
www.national.com/feedback
www.national.com/easy
Clock and Timing
Data Converters
Interface
Reference Designs
Samples
Eval Boards
LVDS
Packaging
Power Management
Green Compliance
Distributors
Switching Regulators www.national.com/switchers
LDOs
www.national.com/ldo
www.national.com/led
www.national.com/vref
www.national.com/powerwise
Quality and Reliability
Feedback/Support
Design Made Easy
Applications & Markets
Mil/Aero
LED Lighting
Voltage References
PowerWise® Solutions
www.national.com/solutions
www.national.com/milaero
www.national.com/solarmagic
www.national.com/training
Serial Digital Interface (SDI) www.national.com/sdi
Temperature Sensors
PLL/VCO
www.national.com/tempsensors SolarMagic™
www.national.com/wireless
PowerWise® Design
University
THE CONTENTS OF THIS DOCUMENT ARE PROVIDED IN CONNECTION WITH NATIONAL SEMICONDUCTOR CORPORATION
(“NATIONAL”) PRODUCTS. NATIONAL MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE ACCURACY
OR COMPLETENESS OF THE CONTENTS OF THIS PUBLICATION AND RESERVES THE RIGHT TO MAKE CHANGES TO
SPECIFICATIONS AND PRODUCT DESCRIPTIONS AT ANY TIME WITHOUT NOTICE. NO LICENSE, WHETHER EXPRESS,
IMPLIED, ARISING BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS
DOCUMENT.
TESTING AND OTHER QUALITY CONTROLS ARE USED TO THE EXTENT NATIONAL DEEMS NECESSARY TO SUPPORT
NATIONAL’S PRODUCT WARRANTY. EXCEPT WHERE MANDATED BY GOVERNMENT REQUIREMENTS, TESTING OF ALL
PARAMETERS OF EACH PRODUCT IS NOT NECESSARILY PERFORMED. NATIONAL ASSUMES NO LIABILITY FOR
APPLICATIONS ASSISTANCE OR BUYER PRODUCT DESIGN. BUYERS ARE RESPONSIBLE FOR THEIR PRODUCTS AND
APPLICATIONS USING NATIONAL COMPONENTS. PRIOR TO USING OR DISTRIBUTING ANY PRODUCTS THAT INCLUDE
NATIONAL COMPONENTS, BUYERS SHOULD PROVIDE ADEQUATE DESIGN, TESTING AND OPERATING SAFEGUARDS.
EXCEPT AS PROVIDED IN NATIONAL’S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NATIONAL ASSUMES NO
LIABILITY WHATSOEVER, AND NATIONAL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO THE SALE
AND/OR USE OF NATIONAL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR
PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY
RIGHT.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR
SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL
COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein:
Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected
to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness.
National Semiconductor and the National Semiconductor logo are registered trademarks of National Semiconductor Corporation. All other
brand or product names may be trademarks or registered trademarks of their respective holders.
Copyright© 2011 National Semiconductor Corporation
For the most current product information visit us at www.national.com
National Semiconductor
Americas Technical
Support Center
National Semiconductor Europe
Technical Support Center
Email: europe.support@nsc.com
National Semiconductor Asia
Pacific Technical Support Center
Email: ap.support@nsc.com
National Semiconductor Japan
Technical Support Center
Email: jpn.feedback@nsc.com
Email: support@nsc.com
Tel: 1-800-272-9959
www.national.com
200316 Version 5 Revision 3 Print Date/Time: 2011/07/19 21:23:17
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Audio
Applications
www.ti.com/audio
amplifier.ti.com
dataconverter.ti.com
www.dlp.com
Communications and Telecom www.ti.com/communications
Amplifiers
Data Converters
DLP® Products
DSP
Computers and Peripherals
Consumer Electronics
Energy and Lighting
Industrial
www.ti.com/computers
www.ti.com/consumer-apps
www.ti.com/energy
dsp.ti.com
www.ti.com/industrial
www.ti.com/medical
www.ti.com/security
Clocks and Timers
Interface
www.ti.com/clocks
interface.ti.com
logic.ti.com
Medical
Security
Logic
Space, Avionics and Defense www.ti.com/space-avionics-defense
Transportation and Automotive www.ti.com/automotive
Power Mgmt
Microcontrollers
RFID
power.ti.com
microcontroller.ti.com
www.ti-rfid.com
Video and Imaging
www.ti.com/video
OMAP Mobile Processors www.ti.com/omap
Wireless Connectivity www.ti.com/wirelessconnectivity
TI E2E Community Home Page
e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated
相关型号:
![](http://pdffile.icpdf.com/pdf1/p00173/img/page/DS949_970096_files/DS949_970096_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00173/img/page/DS949_970096_files/DS949_970096_2.jpg)
DS9490R_11
USB to 1-Wire/iButton Adapters High-Speed 12Mbps Universal Serial Bus (USB) Interface
MAXIM
![](http://pdffile.icpdf.com/pdf2/p00238/img/page/DS9502P-T-AM_1439780_files/DS9502P-T-AM_1439780_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00238/img/page/DS9502P-T-AM_1439780_files/DS9502P-T-AM_1439780_2.jpg)
DS9502P
Trans Voltage Suppressor Diode, Unidirectional, 1 Element, Silicon, 3.70 X 4 MM, 1.50 MM HEIGHT, TSOC-6
MAXIM
©2020 ICPDF网 联系我们和版权申明