SNJ54ABT18646HVR [TI]

ABT SERIES, DUAL 9-BIT BOUNDARY SCAN REG TRANSCEIVER, TRUE OUTPUT, CQFP68, CERAMIC, QFP-68;
SNJ54ABT18646HVR
型号: SNJ54ABT18646HVR
厂家: TEXAS INSTRUMENTS    TEXAS INSTRUMENTS
描述:

ABT SERIES, DUAL 9-BIT BOUNDARY SCAN REG TRANSCEIVER, TRUE OUTPUT, CQFP68, CERAMIC, QFP-68

信息通信管理 输出元件 逻辑集成电路
文件: 总32页 (文件大小:483K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
Members of the Texas Instruments  
SCOPE Instruction Set  
– IEEE Standard 1149.1-1990 Required  
Instructions, Optional INTEST, CLAMP  
and HIGHZ  
SCOPE Family of Testability Products  
Members of the Texas Instruments  
Widebus Family  
– Parallel-Signature Analysis at Inputs With  
Masking Option  
– Pseudo-Random Pattern Generation  
From Outputs  
– Sample Inputs/Toggle Outputs  
– Binary Count From Outputs  
– Device Identification  
Compatible With the IEEE Standard  
1149.1-1990 (JTAG) Test Access Port and  
Boundary-Scan Architecture  
Includes D-Type Flip-Flops and Control  
Circuitry to Provide Multiplexed  
Transmission of Stored and Real-Time Data  
Two Boundary-Scan Cells per I/O for  
– Even-Parity Opcodes  
Greater Flexibility  
Packaged in 68-Pin Ceramic Quad Flat  
State-of-the-Art EPIC-ΙΙB BiCMOS Design  
Package  
Significantly Reduces Power Dissipation  
HV PACKAGE  
(TOP VIEW)  
9
8
7
6
5
4
3
2
1 68 67 66 65 64 63 62 61  
1A3  
1A4  
1A5  
GND  
1A6  
1A7  
1A8  
1A9  
NC  
1B4  
1B5  
1B6  
GND  
1B7  
1B8  
1B9  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
60  
59  
58  
57  
56  
55  
54  
53  
52  
51  
50  
49  
48  
47  
46  
45  
44  
V
CC  
NC  
V
2B1  
2B2  
2B3  
2B4  
GND  
2B5  
2B6  
2B7  
CC  
2A1  
2A2  
2A3  
GND  
2A4  
2A5  
2A6  
27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43  
NC – No internal connection  
SCOPE, Widebus, and EPIC-ΙΙB are trademarks of Texas Instruments Incorporated.  
Copyright 1994, Texas Instruments Incorporated  
PRODUCTION DATA information is current as of publication date.  
Products conform to specifications per the terms of Texas Instruments  
standard warranty. Production processing does not necessarily include  
testing of all parameters.  
4–1  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
description  
The SN54ABT18646 scan test device with 18-bit bus transceivers and registers is a member of the Texas  
Instruments SCOPE testability integrated circuit family. This family of devices supports IEEE Standard  
1149.1-1990 boundary scan to facilitate testing of complex circuit-board assemblies. Scan access to the test  
circuitry is accomplished via the 4-wire test access port (TAP) interface.  
In the normal mode, the SN54ABT18646 is an 18-bit bus transceiver and register that allows for multiplexed  
transmission of data directly from the input bus or from the internal registers. It can be used either as two 9-bit  
transceivers or one 18-bit transceiver. The test circuitry can be activated by the TAP to take snapshot samples  
of the data appearing at the device pins or to perform a self test on the boundary-test cells. Activating the TAP  
in the normal mode does not affect the functional operation of the SCOPE bus transceivers and registers.  
Transceiver function is controlled by output-enable (OE) and direction (DIR) inputs. When OE is low, the  
transceiver is active and operates in the A-to-B direction when DIR is high or in the B-to-A direction when DIR  
is low. When OE is high, both the A and B outputs are in the high-impedance state, effectively isolating both  
buses.  
Data flow is controlled by clock (CLKAB and CLKBA) and select (SAB and SBA) inputs. Data on the A bus is  
clocked into the associated registers on the low-to-high transition of CLKAB. When SAB is low, real-time A data  
is selected for presentation to the B bus (transparent mode). When SAB is high, stored A data is selected for  
presentation to the B bus (registered mode). The function of the CLKBA and SBA inputs mirrors that of CLKAB  
and SAB, respectively. Figure 1 illustrates the four fundamental bus-management functions that can be  
performed with the  
ABT18646.  
In the test mode, the normal operation of the SCOPE bus transceivers and registers is inhibited, and the test  
circuitry is enabled to observe and control the I/O boundary of the device. When enabled, the test circuitry can  
perform boundary-scan test operations according to the protocol described in IEEE Standard 1149.1-1990.  
Four dedicated test pins observe and control the operation of the test circuitry: test data input (TDI), test data  
output (TDO), test mode select (TMS), and test clock (TCK). Additionally, the test circuitry performs other testing  
functions such as parallel-signature analysis (PSA) on data inputs and pseudo-random pattern generation  
(PRPG) from data outputs. All testing and scan operations are synchronized to the TAP interface.  
Additional flexibility is provided in the test mode through the use of two boundary scan cells (BSCs) for each  
I/O pin. This allows independent test data to be captured and forced at either bus (A or B). A PSA/COUNT  
instruction also is included to ease the testing of memories and other circuits where a binary count addressing  
scheme is useful.  
The SN54ABT18646 is characterized over the full military temperature range of 55°C to 125°C.  
FUNCTION TABLE  
(normal mode, each 9-bit section)  
INPUTS  
DATA I/O  
OPERATION OR FUNCTION  
OE  
X
X
H
H
L
DIR  
X
CLKAB  
CLKBA  
SAB  
X
SBA  
X
A1 THRU A9  
B1 THRU B9  
X
Input  
Unspecified  
Input  
Store A, B unspecified  
Store B, A unspecified  
Store A and B data  
X
X
X
X
Unspecified  
X
X
X
Input  
Input  
X
L
L
X
X
X
X
X
X
Input disabled  
Output  
Input disabled  
Input  
Isolation, hold storage  
Real-time B data to A bus  
Stored B data to A bus  
Real-time A data to B bus  
Stored A data to B bus  
L
X
X
X
X
X
L
L
L
X
H
Output  
Input disabled  
Output  
L
H
H
L
X
Input  
L
H
X
Input disabled  
Output  
The data output functions can be enabled or disabled by various signals at the OE and DIR inputs. Data input functions are always enabled; i.e.,  
data at the bus pins is stored on every low-to-high transition of the clock inputs.  
4–2  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
DIR CLKAB CLKBA SAB  
SBA  
L
DIR  
H
CLKAB CLKBA SAB  
SBA  
X
OE  
L
OE  
L
L
X
X
X
X
X
L
REAL-TIME TRANSFER  
BUS B TO BUS A  
REAL-TIME TRANSFER  
BUS A TO BUS B  
DIR CLKAB CLKBA SAB  
SBA  
X
DIR  
CLKAB CLKBA SAB  
SBA  
OE  
X
OE  
X
X
X
X
X
X
X
X
L
L
L
X
X
X
X
X
H
H
X
X
X
H
H
X
STORAGE FROM  
A, B, OR A AND B  
TRANSFER STORED DATA  
TO A AND/OR B  
Figure 1. Bus-Management Functions  
4–3  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
functional block diagram  
Boundary-Scan Register  
7
1OE  
65  
67  
66  
4
1DIR  
1CLKBA  
1SBA  
1CLKAB  
1SAB  
5
C1  
1D  
8
63  
1B1  
1A1  
2OE  
C1  
1D  
One of Nine Channels  
31  
41  
38  
39  
2DIR  
2CLKBA  
2SBA  
33  
32  
2CLKAB  
2SAB  
C1  
1D  
20  
51  
2B1  
2A1  
C1  
1D  
One of Nine Channels  
Bypass Register  
Boundary-Control  
Register  
Identification  
Register  
V
3
CC  
34  
TDO  
Instruction  
Register  
TDI  
V
CC  
68  
TMS  
TCK  
TAP  
Controller  
37  
4–4  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
Terminal Functions  
TERMINAL NAME  
DESCRIPTION  
1A1–1A9,  
2A12A9  
Normal-function A-bus I/O ports. See function table for normal-mode logic.  
Normal-function B-bus I/O ports. See function table for normal-mode logic.  
Normal-function clock inputs. See function table for normal-mode logic.  
1B1–1B9,  
2B12B9  
1CLKAB, 1CLKBA,  
2CLKAB, 2CLKBA  
1DIR, 2DIR  
GND  
Normal-function direction controls. See function table for normal-mode logic.  
Ground  
1OE, 2OE  
Normal-function output enables. See function table for normal-mode logic.  
1SAB, 1SBA,  
2SAB, 2SBA  
Normal-function select controls. See function table for normal-mode logic.  
Test clock. One of four terminals required by IEEE Standard 1149.1-1990. Test operations of the device are synchronous  
to TCK. Data is captured on the rising edge of TCK and outputs change on the falling edge of TCK.  
TCK  
TDI  
Test data input. One of four terminals required by IEEE Standard 1149.1-1990. TDI is the serial input for shifting data  
through the instruction register or selected data register. An internal pullup forces TDI to a high level if left unconnected.  
Test data output. One of four terminals required by IEEE Standard 1149.1-1990. TDO is the serial output for shifting data  
through the instruction register or selected data register.  
TDO  
TMS  
Test mode select. One of four terminals required by IEEE Standard 1149.1-1990. TMS directs the device through its TAP  
controller states. An internal pullup forces TMS to a high level if left unconnected.  
V
CC  
Supply voltage  
4–5  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
test architecture  
Serial-test information is conveyed by means of a 4-wire test bus or TAP that conforms to IEEE Standard  
1149.1-1990. Test instructions, test data, and test control signals all are passed along this serial-test bus. The  
TAP controller monitors two signals from the test bus, namely TCK and TMS. The TAP controller extracts the  
synchronization (TCK) and state control (TMS) signals from the test bus and generate the appropriate on-chip  
control signals for the test structures in the device. Figure 2 shows the TAP-controller state diagram.  
The TAP controller is fully synchronous to the TCK signal. Input data is captured on the rising edge of TCK, and  
output data changes on the falling edge of TCK. This scheme ensures that data to be captured is valid for fully  
one-half of the TCK cycle.  
The functional block diagram illustrates the IEEE Standard 1149.1-1990 4-wire test bus and boundary-scan  
architecture and the relationship among the test bus, the TAP controller, and the test registers. As illustrated,  
the device contains an 8-bit instruction register and four test data registers: an 88-bit boundary-scan register,  
a 21-bit boundary-control register, a 1-bit bypass register, and a 32-bit device-identification register.  
Test-Logic-Reset  
TMS = H  
TMS = L  
TMS = H  
TMS = H  
TMS = H  
Run-Test/Idle  
Select-DR-Scan  
TMS = L  
Select-IR-Scan  
TMS = L  
TMS = L  
TMS = H  
TMS = H  
Capture-DR  
TMS = L  
Capture-IR  
TMS = L  
Shift-DR  
Shift-IR  
TMS = L  
TMS = L  
TMS = H  
TMS = H  
TMS = H  
Exit1-IR  
TMS = H  
Exit1-DR  
TMS = L  
TMS = L  
Pause-DR  
TMS = H  
Pause-IR  
TMS = H  
Exit2-IR  
TMS = L  
TMS = L  
TMS = L  
TMS = L  
Exit2-DR  
TMS = H  
TMS = H  
Update-DR  
Update-IR  
TMS = H  
TMS = L  
TMS = H  
TMS = L  
Figure 2. TAP-Controller State Diagram  
4–6  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
state diagram description  
TheTAPcontrollerisasynchronousfinitestatemachinethatprovidestestcontrolsignalsthroughoutthedevice.  
The state diagram is illustrated in Figure 2 and is in accordance with IEEE Standard 1149.1-1990. The TAP  
controller proceeds through its states based on the level of TMS at the rising edge of TCK.  
As illustrated, the TAP controller consists of 16 states. There are six stable states (indicated by a looping arrow  
in the state diagram) and ten unstable states. A stable state is defined as a state the TAP controller can retain  
for consecutive TCK cycles. Any state that does not meet this criterion is an unstable state.  
There are two main paths through the state diagram: one to access and control the selected data register and  
one to access and control the instruction register. Only one register can be accessed at a time.  
Test-Logic-Reset  
The device powers up in the Test-Logic-Reset state. In the stable Test-Logic-Reset state, the test logic is reset  
and is disabled so that the normal logic function of the device is performed. The instruction register is reset to  
an opcode that selects the optional IDCODE instruction, if supported, or the BYPASS instruction. Certain data  
registers also can be reset to their power-up values.  
The state machine is constructed such that the TAP controller returns to the Test-Logic-Reset state in no more  
than five TCK cycles if TMS is left high. The TMS pin has an internal pullup resistor that forces it high if left  
unconnected or if a board defect causes it to be open circuited.  
For the SN54ABT18646, the instruction register is reset to the binary value 10000001, which selects the  
IDCODE instruction. Bits 8784 in the boundary-scan register are reset to logic 0, ensuring that these cells,  
which control A-port and B-port outputs, are set to benign values (i.e., if test mode were invoked, the outputs  
would be at high impedance state). Reset values of other bits in the boundary-scan register should be  
consideredindeterminate. Theboundary-controlregisterisresettothebinaryvalue000000000000000000010,  
which selects the PSA test operation with no input masking.  
Run-Test/Idle  
The TAP controller must pass through the Run-Test/Idle state (from Test-Logic-Reset) before executing any test  
operations. The Run-Test/Idle state also can be entered following data-register or instruction-register scans.  
Run-Test/Idle is a stable state in which the test logic can be actively running a test or can be idle.  
The test operations selected by the boundary-control register are performed while the TAP controller is in the  
Run-Test/Idle state.  
Select-DR-Scan, Select-lR-Scan  
No specific function is performed in the Select-DR-Scan and Select-lR-Scan states, and the TAP controller exits  
either of these states on the next TCK cycle. These states allow the selection of either data-register scan or  
instruction-register scan.  
Capture-DR  
When a data-register scan is selected, the TAP controller must pass through the Capture-DR state. In the  
Capture-DR state, the selected data register can capture a data value as specified by the current instruction.  
Such capture operations occur on the rising edge of TCK upon which the TAP controller exits the Capture-DR  
state.  
Shift-DR  
Upon entry to the Shift-DR state, the data register is placed in the scan path between TDI and TDO and, on the  
first falling edge of TCK, TDO goes from the high-impedance state to an active state. TDO enables to the logic  
level present in the least significant bit of the selected data register.  
4–7  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
Shift-DR (continued)  
While in the stable Shift-DR state, data is serially shifted through the selected data register on each TCK cycle.  
The first shift occurs on the first rising edge of TCK after entry to the Shift-DR state (i.e., no shifting occurs during  
the TCK cycle in which the TAP controller changes from Capture-DR to Shift-DR or from Exit2-DR to Shift-DR).  
The last shift occurs on the rising edge of TCK upon which the TAP controller exits the Shift-DR state.  
Exit1-DR, Exit2-DR  
The Exit1-DR and Exit2-DR states are temporary states that end a data-register scan. It is possible to return  
to the Shift-DR state from either Exit1-DR or Exit2-DR without recapturing the data register. On the first falling  
edge of TCK after entry to Exit1-DR, TDO goes from the active state to the high-impedance state.  
Pause-DR  
No specific function is performed in the stable Pause-DR state, in which the TAP controller can remain  
indefinitely. The Pause-DR state can suspend and resume data-register scan operations without loss of data.  
Update-DR  
If the current instruction calls for the selected data register to be updated with current data, such update occurs  
on the falling edge of TCK following entry to the Update-DR state.  
Capture-IR  
When an instruction-register scan is selected, the TAP controller must pass through the Capture-IR state. In the  
Capture-IR state, the instruction register captures its current status value. This capture operation occurs on the  
rising edge of TCK upon which the TAP controller exits the Capture-IR state. For the SN54ABT18646, the status  
value loaded in the Capture-IR state is the fixed binary value 10000001.  
Shift-IR  
Upon entry to the Shift-IR state, the instruction register is placed in the scan path between TDI and TDO and,  
on the first falling edge of TCK, TDO goes from the high-impedance state to an active state. TDO enables to  
the logic level present in the least significant bit of the instruction register.  
While in the stable Shift-IR state, instruction data is serially shifted through the instruction register on each TCK  
cycle. The first shift occurs on the first rising edge of TCK after entry to the Shift-IR state (i.e., no shifting occurs  
during the TCK cycle in which the TAP controller changes from Capture-IR to Shift-IR or from Exit2-IR to  
Shift-IR). The last shift occurs on the rising edge of TCK upon which the TAP controller exits the Shift-IR state.  
Exit1-IR, Exit2-IR  
The Exit1-IR and Exit2-IR states are temporary states that end an instruction-register scan. It is possible to  
return to the Shift-IR state from either Exit1-IR or Exit2-IR without recapturing the instruction register. On the  
first falling edge of TCK after entry to Exit1-IR, TDO goes from the active state to the high-impedance state.  
Pause-IR  
NospecificfunctionisperformedinthestablePause-IRstate, inwhichtheTAPcontrollercanremainindefinitely.  
The Pause-IR state can suspend and resume instruction-register scan operations without loss of data.  
Update-IR  
The current instruction is updated and takes effect on the falling edge of TCK following entry to the Update-IR  
state.  
4–8  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
register overview  
With the exception of the bypass and device-identification registers, any test register can be thought of as a  
serial-shift register with a shadow latch on each bit. The bypass and device-identification registers differ in that  
they contain only a shift register. During the appropriate capture state (Capture-IR for instruction register,  
Capture-DR for data registers), the shift register can be parallel loaded from a source specified by the current  
instruction. During the appropriate shift state (Shift-IR or Shift-DR), the contents of the shift register are shifted  
out from TDO while new contents are shifted in at TDI. During the appropriate update state (Update-IR or  
Update-DR), the shadow latches are updated from the shift register.  
instruction register description  
The instruction register (IR) is eight bits long and tells the device what instruction is to be executed. Information  
contained in the instruction includes the mode of operation (either normal mode, in which the device performs  
its normal logic function, or test mode, in which the normal logic function is inhibited or altered), the test operation  
to be performed, which of the four data registers is to be selected for inclusion in the scan path during  
data-register scans, and the source of data to be captured into the selected data register during Capture-DR.  
Table 4 lists the instructions supported by the SN54ABT18646. The even-parity feature specified for SCOPE  
devices is supported in this device. Bit 7 of the instruction opcode is the parity bit. Any instructions that are  
defined for SCOPE devices but are not supported by this device default to BYPASS.  
During Capture-IR, the IR captures the binary value 10000001. As an instruction is shifted in, this value will be  
shifted out via TDO and can be inspected as verification that the IR is in the scan path. During Update-IR, the  
value that has been shifted into the IR is loaded into shadow latches. At this time, the current instruction is  
updated and any specified mode change takes effect. At power up or in the Test-Logic-Reset state, the IR is  
reset to the binary value 10000001, which selects the IDCODE instruction. The IR order of scan is illustrated  
in Figure 3.  
Bit 7  
Parity  
(MSB)  
Bit 0  
(LSB)  
TDI  
TDO  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Figure 3. Instruction Register Order of Scan  
4–9  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
data register description  
boundary-scan register  
The boundary-scan register (BSR) is 88 bits long. It contains one boundary-scan cell (BSC) for each  
normal-function input pin and two BSCs for each normal-function I/O pin (one for input data and one for output  
data). The BSR is used 1) to store test data that is to be applied internally to the inputs of the normal on-chip  
logic and/or externally to the device output pins, and/or 2) to capture data that appears internally at the outputs  
of the normal on-chip logic and/or externally at the device input pins.  
The source of data to be captured into the BSR during Capture-DR is determined by the current instruction. The  
contents of the BSR can change during Run-Test/Idle as determined by the current instruction. At power up or  
in Test-Logic-Reset, BSCs 87–84 are reset to logic 0, ensuring that these cells, which control A-port and B-port  
outputs are set to benign values (i.e., if test mode were invoked, the outputs would be at high impedance state).  
Reset values of other BSCs should be considered indeterminate.  
The BSR order of scan is from TDI through bits 87–0 to TDO. Table 1 shows the BSR bits and their associated  
device pin signals.  
Table 1. Boundary-Scan-Register Configuration  
BSR BIT  
NUMBER  
DEVICE  
SIGNAL  
BSR BIT  
NUMBER  
DEVICE  
SIGNAL  
BSR BIT  
NUMBER  
DEVICE  
SIGNAL  
BSR BIT  
NUMBER  
DEVICE  
SIGNAL  
BSR BIT  
NUMBER  
DEVICE  
SIGNAL  
87  
86  
85  
84  
83  
82  
81  
80  
79  
78  
77  
76  
75  
74  
73  
72  
––  
––  
2OEB  
1OEB  
2OEA  
1OEA  
2DIR  
71  
70  
69  
68  
67  
66  
65  
64  
63  
62  
61  
60  
59  
58  
57  
56  
55  
54  
2A9-I  
2A8-I  
2A7-I  
2A6-I  
2A5-I  
2A4-I  
2A3-I  
2A2-I  
2A1-I  
1A9-I  
1A8-I  
1A7-I  
1A6-I  
1A5-I  
1A4-I  
1A3-I  
1A2-I  
1A1-I  
53  
52  
51  
50  
49  
48  
47  
46  
45  
44  
43  
42  
41  
40  
39  
38  
37  
36  
2A9-O  
2A8-O  
2A7-O  
2A6-O  
2A5-O  
2A4-O  
2A3-O  
2A2-O  
2A1-O  
1A9-O  
1A8-O  
1A7-O  
1A6-O  
1A5-O  
1A4-O  
1A3-O  
1A2-O  
1A1-O  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
2B9-I  
2B8-I  
2B7-I  
2B6-I  
2B5-I  
2B4-I  
2B3-I  
2B2-I  
2B1-I  
1B9-I  
1B8-I  
1B7-I  
1B6-I  
1B5-I  
1B4-I  
1B3-I  
1B2-I  
1B1-I  
17  
16  
15  
14  
13  
12  
11  
10  
9
2B9-O  
2B8-O  
2B7-O  
2B6-O  
2B5-O  
2B4-O  
2B3-O  
2B2-O  
2B1-O  
1B9-O  
1B8-O  
1B7-O  
1B6-O  
1B5-O  
1B4-O  
1B3-O  
1B2-O  
1B1-O  
1DIR  
2OE  
1OE  
2CLKAB  
1CLKAB  
2CLKBA  
1CLKBA  
2SAB  
1SAB  
2SBA  
1SBA  
––  
8
7
6
5
4
3
2
1
––  
0
boundary-control register  
The boundary-control register (BCR) is 21 bits long. The BCR is used in the context of the RUNT instruction to  
implement additional test operations not included in thebasicSCOPE instruction set. Such operations include  
PRPG, PSA with input masking, and binary count up (COUNT). Table 5 shows the test operations that are  
decoded by the BCR.  
During Capture-DR, the contents of the BCR are not changed. At power up or in Test-Logic-Reset, the BCR is  
resettothebinaryvalue000000000000000000010, whichselectsthePSAtestoperationwithnoinputmasking.  
The BCR order of scan is from TDI through bits 20–0 to TDO. Table 2 shows the BCR bits and their associated  
test control signals.  
4–10  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
Table 2. Boundary-Control-Register Configuration  
TEST  
CONTROL  
SIGNAL  
TEST  
CONTROL  
SIGNAL  
TEST  
CONTROL  
SIGNAL  
BCR BIT  
NUMBER  
BCR BIT  
NUMBER  
BCR BIT  
NUMBER  
20  
19  
18  
17  
16  
15  
14  
13  
12  
MASK2.9  
MASK2.8  
MASK2.7  
MASK2.6  
MASK2.5  
MASK2.4  
MASK2.3  
MASK2.2  
MASK2.1  
11  
10  
9
MASK1.9  
MASK1.8  
MASK1.7  
MASK1.6  
MASK1.5  
MASK1.4  
MASK1.3  
MASK1.2  
MASK1.1  
2
OPCODE2  
1
OPCODE1  
0
OPCODE0  
8
––  
––  
––  
––  
––  
––  
––  
––  
––  
––  
––  
––  
7
6
5
4
3
bypass register  
The bypass register is a 1-bit scan path that can be selected to shorten the length of the system scan path,  
thereby reducing the number of bits per test pattern that must be applied to complete a test operation. During  
Capture-DR, the bypass register captures a logic 0. The bypass register order of scan is illustrated in  
Figure 4.  
TDI  
TDO  
Bit 0  
Figure 4. Bypass Register Order of Scan  
device-identification register  
The device-identification register (IDR) is 32 bits long. It can be selected and read to identify the manufacturer,  
part number, and version of this device.  
During Capture-DR, the binary value 00000000000000001000000000101111 (0000802F, hex) is captured in  
the IDR to identify this device as Texas Instruments SN54ABT18646.  
The device identification register order of scan is from TDI through bits 310 to TDO. Table 3 shows the IDR  
bits and their significance.  
4–11  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
Table 3. Device-Identification-Register Configuration  
IDR BIT  
NUMBER  
IDENTIFICATION  
SIGNIFICANCE  
IDR BIT  
NUMBER  
IDENTIFICATION  
SIGNIFICANCE  
IDR BIT  
NUMBER  
IDENTIFICATION  
SIGNIFICANCE  
31  
30  
29  
28  
––  
––  
––  
––  
––  
––  
––  
––  
––  
––  
––  
––  
VERSION3  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
12  
PARTNUMBER15  
PARTNUMBER14  
PARTNUMBER13  
PARTNUMBER12  
PARTNUMBER11  
PARTNUMBER10  
PARTNUMBER09  
PARTNUMBER08  
PARTNUMBER07  
PARTNUMBER06  
PARTNUMBER05  
PARTNUMBER04  
PARTNUMBER03  
PARTNUMBER02  
PARTNUMBER01  
PARTNUMBER00  
11  
10  
9
MANUFACTURER10  
MANUFACTURER09  
MANUFACTURER08  
MANUFACTURER07  
MANUFACTURER06  
MANUFACTURER05  
MANUFACTURER04  
MANUFACTURER03  
MANUFACTURER02  
MANUFACTURER01  
MANUFACTURER00  
VERSION2  
VERSION1  
VERSION0  
8
––  
––  
––  
––  
––  
––  
––  
––  
––  
––  
––  
––  
7
6
5
4
3
2
1
0
LOGIC1  
––  
––  
––  
––  
––  
––  
––  
––  
Note that for TI products, bits 110 of the device identification register always contain the binary value 000000101111  
(02F, hex).  
instruction-register opcode description  
The instruction-register opcodes are shown in Table 4. The following descriptions detail the operation of each  
instruction.  
Table 4. Instruction-Register Opcodes  
BINARY CODE  
BIT 7 BIT 0  
MSB LSB  
SELECTED DATA  
REGISTER  
SCOPE OPCODE  
DESCRIPTION  
MODE  
00000000  
10000001  
10000010  
00000011  
10000100  
00000101  
00000110  
10000111  
10001000  
00001001  
00001010  
10001011  
00001100  
10001101  
10001110  
00001111  
All others  
EXTEST  
IDCODE  
Boundary scan  
Identification read  
Boundary scan  
Device identification  
Boundary scan  
Boundary scan  
Bypass  
Test  
Normal  
Normal  
Test  
SAMPLE/PRELOAD  
INTEST  
Sample boundary  
Boundary scan  
BYPASS  
BYPASS  
HIGHZ  
Bypass scan  
Normal  
Normal  
Modified test  
Test  
Bypass scan  
Bypass  
Control boundary to high impedance  
Control boundary to 1/0  
Bypass scan  
Bypass  
CLAMP  
Bypass  
BYPASS  
Bypass  
Normal  
Test  
RUNT  
Boundary run test  
Bypass  
READBN  
READBT  
CELLTST  
TOPHIP  
SCANCN  
SCANCT  
BYPASS  
Boundary read  
Boundary scan  
Boundary scan  
Boundary scan  
Bypass  
Normal  
Test  
Boundary read  
Boundary self test  
Normal  
Test  
Boundary toggle outputs  
Boundary-control register scan  
Boundary-control register scan  
Bypass scan  
Boundary control  
Boundary control  
Bypass  
Normal  
Test  
Normal  
Bit 7 is used to maintain even parity in the 8-bit instruction.  
The BYPASS instruction is executed in lieu of a SCOPE instruction that is not supported in the SN54ABT18646.  
4–12  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
boundary scan  
This instruction conforms to the IEEE Standard 1149.1-1990 EXTEST and INTEST instructions. The BSR is  
selected in the scan path. Data appearing at the device input pins is captured in the input BSCs, while data  
appearing at the outputs of the normal on-chip logic is captured in the output BSCs. Data scanned into the input  
BSCs is applied to the inputs of the normal on-chip logic, while data scanned into the output BSCs is applied  
to the device output pins. The device operates in the test mode.  
bypass scan  
This instruction conforms to the IEEE Standard 1149.1-1990 BYPASS instruction. The bypass register is  
selected in the scan path. A logic 0 value is captured in the bypass register during Capture-DR. The device  
operates in the normal mode.  
sample boundary  
This instruction conforms to the IEEE Standard 1149.1-1990 SAMPLE/PRELOAD instruction. The BSR is  
selected in the scan path. Data appearing at the device input pins is captured in the input BSCs, while data  
appearing at the outputs of the normal on-chip logic is captured in the output BSCs. The device operates in the  
normal mode.  
control boundary to high impedance  
This instruction conforms to the IEEE Standard 1149.1a-1993 instruction. The bypass register is selected in the  
scan path. A logic 0 value is captured in the bypass register during Capture-DR. The device operates in a  
modified test mode in which all device I/O pins are placed in the high-impedance state, the device input pins  
remain operational, and the normal on-chip logic function is performed.  
control boundary to 1/0  
This instruction conforms to the IEEE Standard 1149.1a-1993 instruction. The bypass register is selected in the  
scanpath. Alogic0valueiscapturedinthebypassregisterduringCapture-DR. DataintheinputBSCsisapplied  
to the inputs of the normal on-chip logic, while data in the output BSCs is applied to the device output pins. The  
device operates in the test mode.  
boundary-run test  
The bypass register is selected in the scan path. A logic 0 value is captured in the bypass register during  
Capture-DR. The device operates in the test mode. The test operation specified in the BCR is executed during  
Run-Test/Idle. The five test operations decoded by the BCR are: sample inputs/toggle outputs (TOPSIP),  
PRPG, PSA, simultaneous PSA and PRPG (PSA/PRPG), and simultaneous PSA and binary count up  
(PSA/COUNT).  
boundary read  
The BSR is selected in the scan path. The value in the BSR remains unchanged during Capture-DR. This  
instruction is useful for inspecting data after a PSA operation.  
boundary self test  
The BSR is selected in the scan path. All BSCs capture the inverse of their current values during Capture-DR.  
In this way, the contents of the shadow latches can be read out to verify the integrity of both shift-register and  
shadow-latch elements of the BSR. The device operates in the normal mode.  
4–13  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
boundary toggle outputs  
The bypass register is selected in the scan path. A logic 0 value is captured in the bypass register during  
Capture-DR. Data in the shift-register elements of the selected output BSCs is toggled on each rising edge of  
TCK in Run-Test/Idle, updated in the shadow latches, and applied to the associated device output pins on each  
falling edge of TCK in Run-Test/Idle. Data in the selected input BSCs remains constant and is applied to the  
inputs of the normal on-chip logic. Data appearing at the device input pins is not captured in the input BSCs.  
The device operates in the test mode.  
boundary-control-register scan  
The BCR is selected in the scan path. The value in the BCR remains unchanged during Capture-DR. This  
operation must be performed before a boundary-run test operation to specify which test operation is to be  
executed.  
boundary-control-register opcode description  
The BCR opcodes are decoded from BCR bits 2–0 as shown in Table 5. The selected test operation is  
performed while the RUNT instruction is executed in the Run-Test/Idle state. The following descriptions detail  
the operation of each BCR instruction and illustrate the associated PSA and PRPG algorithms.  
Table 5. Boundary-Control-Register Opcodes  
BINARY CODE  
BIT 2 BIT 0  
MSB LSB  
DESCRIPTION  
X00  
X01  
X10  
011  
111  
Sample inputs/toggle outputs (TOPSIP)  
Pseudo-random pattern generation/36-bit mode (PRPG)  
Parallel-signature analysis/36-bit mode (PSA)  
Simultaneous PSA and PRPG/18-bit mode (PSA/PRPG)  
Simultaneous PSA and binary count up/18-bit mode (PSA/COUNT)  
While the control input BSCs (bits 8772) are not included in the toggle, PSA, PRPG, or COUNT algorithms,  
the output-enable BSCs (bits 8784 of the BSR) control the drive state (active or high impedance) of the  
selected device output pins. These BCR instructions are valid only when both bytes of the device are operating  
in one direction of data flow (that is, 1OEA 1OEB and 2OEA 2OEB) and in the same direction of data flow  
(that is, 1OEA = 2OEA and 1OEB = 2OEB). Otherwise, the bypass instruction is operated.  
PSA input masking  
Bits 20–3 of the BCR are used to specify device input pins to be masked from PSA operations. Bit 20 selects  
masking for device input pin 2A9 during A-to-B data flow or for device input pin 2B9 during B-to-A data flow.  
Bit 3 selects masking for device input pins 1A1 or 1B1 during A-to-B or B-to-A data flow, respectively. Bits  
intermediate to 20 and 3 mask corresponding device input pins in order from most significant to least significant,  
as indicated in Table 2. When the mask bit that corresponds to a particular device input has a logic 1 value, the  
device input pin is masked from any PSA operation, meaning that the state of the device input pin is ignored  
and has no effect on the generated signature. Otherwise, when a mask bit has a logic 0 value, the corresponding  
device input is not masked from the PSA operation.  
sample inputs/toggle outputs (TOPSIP)  
Data appearing at the selected device input pins is captured in the shift-register elements of the selected BSCs  
on each rising edge of TCK. This data is updated in the shadow latches of the selected input BSCs and applied  
to the inputs of the normal on-chip logic. Data in the shift-register elements of the selected output BSCs is  
toggled on each rising edge of TCK, updated in the shadow latches, and applied to the associated device output  
pins on each falling edge of TCK.  
4–14  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
pseudo-random pattern generation (PRPG)  
A pseudo-random pattern is generated in the shift-register elements of the selected BSCs on each rising edge  
of TCK, updated in the shadow latches, and applied to the associated device output pins on each falling edge  
of TCK. This data also is updated in the shadow latches of the selected input BSCs and applied to the inputs  
of the normal on-chip logic. Figures 5 and 6 illustrate the 36-bit linear-feedback shift-register algorithms through  
which the patterns are generated. An initial seed value should be scanned into the BSR before performing this  
operation. A seed value of all zeroes does not produce additional patterns.  
2A9-I  
2A8-I  
2A7-I  
2A6-I  
2A5-I  
2A4-I  
2A3-I  
2A2-I  
2A1-I  
1A9-I  
1A8-I  
1A7-I  
1A6-I  
1A5-I  
1A4-I  
1A3-I  
1A2-I  
1A1-I  
2B9-O  
1B9-O  
2B8-O  
1B8-O  
2B7-O  
1B7-O  
2B6-O  
1B6-O  
2B5-O  
1B5-O  
2B4-O  
1B4-O  
2B3-O  
1B3-O  
2B2-O  
1B2-O  
2B1-O  
1B1-O  
=
Figure 5. 36-Bit PRPG Configuration (1OEA = 2OEA = 0, 1OEB = 2OEB = 1)  
4–15  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
2B9-I  
2B8-I  
2B7-I  
2B6-I  
1B6-I  
2B5-I  
1B5-I  
2B4-I  
1B4-I  
2B3-I  
1B3-I  
2B2-I  
1B2-I  
2B1-I  
1B1-I  
1B9-I  
1B8-I  
1B7-I  
2A9-O  
1A9-O  
2A8-O  
1A8-O  
2A7-O  
1A7-O  
2A6-O  
1A6-O  
2A5-O  
1A5-O  
2A4-O  
1A4-O  
2A3-O  
1A3-O  
2A2-O  
1A2-O  
2A1-O  
1A1-O  
=
Figure 6. 36-Bit PRPG Configuration (1OEA = 2OEA = 1, 1OEB = 2OEB = 0)  
4–16  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
parallel-signature analysis (PSA)  
Data appearing at the selected device input pins is compressed into a 36-bit parallel signature in the  
shift-register elements of the selected BSCs on each rising edge of TCK. This data is updated in the shadow  
latches of the selected input BSCs and applied to the inputs of the normal on-chip logic. Data in the shadow  
latches of the selected output BSCs remains constant and is applied to the device outputs. Figures 7 and 8  
illustrate the 36-bit linear-feedback shift-register algorithms through which the signature is generated. An initial  
seed value should be scanned into the BSR before to performing this operation.  
2A9-I  
2A8-I  
2A7-I  
2A6-I  
2A5-I  
2A4-I  
2A3-I  
2A2-I  
2A1-I  
1A9-I  
1A8-I  
1A7-I  
1A6-I  
1A5-I  
1A4-I  
1A3-I  
1A2-I  
1A1-I  
2B9-O  
1B9-O  
2B8-O  
1B8-O  
2B7-O  
1B7-O  
2B6-O  
1B6-O  
2B5-O  
1B5-O  
2B4-O  
1B4-O  
2B3-O  
1B3-O  
2B2-O  
1B2-O  
2B1-O  
1B1-O  
=
=
Figure 7. 36-Bit PSA Configuration (1OEA = 2OEA = 0, 1OEB = 2OEB = 1)  
4–17  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
2B9-I  
2B8-I  
2B7-I  
2B6-I  
1B6-I  
2B5-I  
1B5-I  
2B4-I  
1B4-I  
2B3-I  
1B3-I  
2B2-I  
1B2-I  
2B1-I  
1B1-I  
1B9-I  
1B8-I  
1B7-I  
2A9-O  
1A9-O  
2A8-O  
1A8-O  
2A7-O  
1A7-O  
2A6-O  
1A6-O  
2A5-O  
1A5-O  
2A4-O  
1A4-O  
2A3-O  
1A3-O  
2A2-O  
1A2-O  
2A1-O  
1A1-O  
=
=
Figure 8. 36-Bit PSA Configuration (1OEA = 2OEA = 1, 1OEB = 2OEB = 0)  
4–18  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
simultaneous PSA and PRPG (PSA/PRPG)  
Data appearing at the selected device input pins is compressed into an 18-bit parallel signature in the  
shift-register elements of the selected input BSCs on each rising edge of TCK. This data is updated in the  
shadow latches of the selected input BSCs and applied to the inputs of the normal on-chip logic. At the same  
time, an 18-bit pseudo-random pattern is generated in the shift-register elements of the selected output BSCs  
on each rising edge of TCK, updated in the shadow latches, and applied to the associated device output pins  
on each falling edge of TCK. Figures 9 and 10 illustrate the 18-bit linear-feedback shift-register algorithms  
through which the signature and patterns are generated. An initial seed value should be scanned into the BSR  
before performing this operation. A seed value of all zeroes does not produce additional patterns.  
2A9-I  
2A8-I  
2A7-I  
2A6-I  
2A5-I  
2A4-I  
2A3-I  
2A2-I  
2A1-I  
1A9-I  
1A8-I  
1A7-I  
1A6-I  
1A5-I  
1A4-I  
1A3-I  
1A2-I  
1A1-I  
2B9-O  
2B8-O  
2B7-O  
2B6-O  
2B5-O  
2B4-O  
2B3-O  
2B2-O  
2B1-O  
=
=
1B9-O  
1B8-O  
1B7-O  
1B6-O  
1B5-O  
1B4-O  
1B3-O  
1B2-O  
1B1-O  
Figure 9. 18-Bit PSA/PRPG Configuration (1OEA = 2OEA = 0, 1OEB = 2OEB = 1)  
4–19  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
2B9-I  
2B8-I  
2B7-I  
2B6-I  
2B5-I  
2B4-I  
2B3-I  
2B2-I  
2B1-I  
1B9-I  
1B8-I  
1B7-I  
1B6-I  
1B5-I  
1B4-I  
1B3-I  
1B2-I  
1B1-I  
2A9-O  
2A8-O  
2A7-O  
2A6-O  
2A5-O  
2A4-O  
2A3-O  
2A2-O  
2A1-O  
=
=
1A9-O  
1A8-O  
1A7-O  
1A6-O  
1A5-O  
1A4-O  
1A3-O  
1A2-O  
1A1-O  
Figure 10. 18-Bit PSA/PRPG Configuration (1OEA = 2OEA = 1, 1OEB = 2OEB = 0)  
4–20  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
simultaneous PSA and binary count up (PSA/COUNT)  
Data appearing at the selected device input pins is compressed into an 18-bit parallel signature in the  
shift-register elements of the selected input BSCs on each rising edge of TCK. This data is updated in the  
shadow latches of the selected input BSCs and applied to the inputs of the normal on-chip logic. At the same  
time, an 18-bit binary count-up pattern is generated in the shift-register elements of the selected output BSCs  
on each rising edge of TCK, updated in the shadow latches, and applied to the associated device output pins  
on each falling edge of TCK. Figures 11 and 12 illustrate the 18-bit linear-feedback shift-register algorithms  
through which the signature is generated. An initial seed value should be scanned into the BSR before  
performing this operation.  
2A9-I  
2A8-I  
2A7-I  
2A6-I  
2A5-I  
2A4-I  
2A3-I  
2A2-I  
2A1-I  
1A9-I  
1A8-I  
1A7-I  
1A6-I  
1A5-I  
1A4-I  
1A3-I  
1A2-I  
1A1-I  
MSB  
2B9-O  
2B8-O  
2B7-O  
2B6-O  
2B5-O  
2B4-O  
2B3-O  
2B2-O  
2B1-O  
LSB  
=
=
1B9-O  
1B8-O  
1B7-O  
1B6-O  
1B5-O  
1B4-O  
1B3-O  
1B2-O  
1B1-O  
Figure 11. 18-Bit PSA/COUNT Configuration (1OEA = 2OEA = 0, 1OEB = 2OEB = 1)  
4–21  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
2B9-I  
2B8-I  
2B7-I  
2B6-I  
2B5-I  
2B4-I  
2B3-I  
2B2-I  
2B1-I  
1B9-I  
1B8-I  
1B7-I  
1B6-I  
1B5-I  
1B4-I  
1B3-I  
1B2-I  
1B1-I  
MSB  
2A9-O  
2A8-O  
2A7-O  
2A6-O  
2A5-O  
2A4-O  
2A3-O  
2A2-O  
2A1-O  
LSB  
=
=
1A9-O  
1A8-O  
1A7-O  
1A6-O  
1A5-O  
1A4-O  
1A3-O  
1A2-O  
1A1-O  
Figure 12. 18-Bit PSA/COUNT Configuration (1OEA = 2OEA = 1, 1OEB = 2OEB = 0)  
4–22  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
timing description  
All test operations of the SN54ABT18646 are synchronous to the TCK signal. Data on the TDI, TMS, and  
normal-function inputs is captured on the rising edge of TCK. Data appears on the TDO and normal-function  
output pins on the falling edge of TCK. The TAP controller is advanced through its states (as illustrated in  
Figure 2) by changing the value of TMS on the falling edge of TCK and then applying a rising edge to TCK.  
A simple timing example is illustrated in Figure 13. In this example, the TAP controller begins in the  
Test-Logic-Reset state and is advanced through its states as necessary to perform one instruction-register scan  
and one data-register scan. While in the Shift-IR and Shift-DR states, TDI is used to input serial data, and TDO  
is used to output serial data. The TAP controller is then returned to the Test-Logic-Reset state. Table 6 explains  
the operation of the test circuitry during each TCK cycle.  
Table 6. Explanation of Timing Example  
TCK  
CYCLE(S)  
TAP STATE  
AFTER TCK  
DESCRIPTION  
TMS is changed to a logic 0 value on the falling edge of TCK to begin advancing the TAP controller toward  
the desired state.  
1
Test-Logic-Reset  
2
3
4
Run-Test/Idle  
Select-DR-Scan  
Select-IR-Scan  
The IR captures the 8-bit binary value 10000001 on the rising edge of TCK as the TAP controller exits the  
Capture-IR state.  
5
6
Capture-IR  
Shift-IR  
TDO becomes active and TDI is made valid on the falling edge of TCK. The first bit is shifted into the TAP on  
the rising edge of TCK as the TAP controller advances to the next state.  
One bit is shifted into the IR on each TCK rising edge. With TDI held at a logic 1 value, the 8-bit binary value  
11111111 is serially scanned into the IR. At the same time, the 8-bit binary value 10000001 is serially scanned  
out of the IR via TDO. In TCK cycle 13 TMS is changed to a logic 1 value to end the IR scan on the next TCK  
cycle. The last bit of the instruction is shifted as the TAP controller advances from Shift-IR to Exit1-IR.  
7–13  
Shift-IR  
14  
15  
16  
Exit1-IR  
Update-IR  
TDO becomes inactive (goes to the high-impedance state) on the falling edge of TCK.  
The IR is updated with the new instruction (BYPASS) on the falling edge of TCK.  
Select-DR-Scan  
The bypass register captures a logic 0 value on the rising edge of TCK as the TAP controller exits the  
Capture-DR state.  
17  
18  
Capture-DR  
Shift-DR  
TDO becomes active and TDI is made valid on the falling edge of TCK. The first bit is shifted into the TAP on  
the rising edge of TCK as the TAP controller advances to the next state.  
1920  
21  
Shift-DR  
Exit1-DR  
The binary value 101 is shifted in via TDI, while the binary value 010 is shifted out via TDO.  
TDO becomes inactive (goes to the high-impedance state) on the falling edge of TCK.  
In general, the selected data register is updated with the new data on the falling edge of TCK.  
22  
Update-DR  
23  
Select-DR-Scan  
Select-IR-Scan  
24  
25  
Test-Logic-Reset Test operation completed  
4–23  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25  
TCK  
TMS  
TDI  
TDO  
TAP  
Controller  
State  
3-State (TDO) or Don’t Care (TDI)  
Figure 13. Timing Example  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage range, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 7 V  
CC  
Input voltage range, V (except I/O ports) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 7 V  
I
Input voltage range, V (I/O ports) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 5.5 V  
I
Voltage range applied to any output in the high state or power-off state, V  
. . . . . . . . . . . . . 0.5 V to 5.5 V  
O
Current into any output in the low state, I  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 mA  
O
Input clamp current, I (V < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –18 mA  
IK  
I
Output clamp current, I  
(V < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA  
OK  
O
Maximum package power dissipation at T = 55°C (in still air) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 885 mW  
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C  
A
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
NOTE 1: The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.  
recommended operating conditions (see Note 2)  
SN54ABT18646  
UNIT  
MIN  
4.5  
2
MAX  
V
V
V
V
Supply voltage  
5.5  
V
V
CC  
High-level input voltage  
Low-level input voltage  
Input voltage  
IH  
0.8  
V
IL  
0
V
V
I
CC  
I
I
High-level output current  
Low-level output current  
Input transition rise or fall rate  
Operating free-air temperature  
24  
48  
mA  
mA  
ns/V  
°C  
OH  
OL  
t/v  
10*  
125  
T
55  
A
*Not production tested on products compliant to MILSTD883D  
NOTE 2: Unused or floating pins (input or I/O) must be held high or low.  
4–24  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
T
= 25°C  
SN54ABT18646  
A
PARAMETER  
TEST CONDITIONS  
UNIT  
MIN TYP  
MAX  
MIN  
MAX  
V
V
V
V
V
V
= 4.5 V,  
= 4.5 V,  
= 5 V,  
I = –18 mA  
–1.2  
–1.2  
V
IK  
CC  
CC  
CC  
CC  
CC  
I
I
I
I
I
I
I
= – 3 mA  
= – 3 mA  
= – 24 mA  
= – 32 mA  
= 48 mA**  
= 64 mA  
2.5  
3
2.5  
3
OH  
OH  
OH  
OH  
OL  
OL  
V
OH  
V
= 4.5 V,  
= 4.5 V,  
2
2
2*  
0.55  
0.55*  
±1  
0.55  
V
OL  
V
= 4.5 V  
= 5.5 V,  
V
CC  
CC  
CLK, DIR, OE, S, TCK  
A or B ports  
±1  
±100  
10  
I
I
V
V = V  
I
or GND  
µA  
CC  
±100  
10  
I
I
I
I
I
I
I
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
V
CC  
= 5.5 V,  
= 5.5 V,  
= 5.5 V,  
= 5.5 V,  
= 0,  
V = V  
I
TDI, TMS  
µA  
µA  
µA  
µA  
µA  
µA  
mA  
IH  
CC  
V = GND  
I
TDI, TMS  
–160  
50  
–160  
50  
IL  
V
O
V
O
= 2.7 V  
OZH  
= 0.5 V  
50  
±100*  
50*  
50  
OZL  
off  
V or V 5.5 V  
I
O
= 5.5 V,  
= 5.5 V,  
V
= 5.5 V  
Outputs high  
50*  
–180  
5.5  
38  
CEX  
O
O
§
V
= 2.5 V  
50  
–100  
0.9  
30  
–180  
5.5  
50  
O
Outputs high  
Outputs low  
V
I
= 5.5 V,  
= 0,  
CC  
O
I
A or B ports  
38  
mA  
CC  
V = V  
I
or GND  
CC  
Outputs disabled  
0.9  
5
5
V
= 5.5 V,  
One input at 3.4 V, Other inputs at V  
or GND  
CC  
1.5  
1.5  
5.8  
12.2  
8.5  
mA  
pF  
pF  
pF  
I  
CC  
CC  
V = 2.5 V or 0.5 V  
C
C
C
Control inputs  
A or B ports  
TDO  
3
10  
8
i
I
V
= 2.5 V or 0.5 V  
= 2.5 V or 0.5 V  
io  
o
O
O
V
*On products compliant to MIL-STD-883, Class B, this parameter does not apply.  
**I = 24 mA for products compliant to 883D  
OL  
§
All typical values are at V  
= 5 V.  
CC  
and I  
The parameters I  
include the input leakage current.  
OZH  
OZL  
Not more than one output should be tested at a time, and the duration of the test should not exceed one second  
This is the increase in supply current for each input that is at the specified TTL voltage level rather than V  
or GND.  
CC  
4–25  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
timing requirements over recommended ranges of supply voltage and operating free-air  
temperature (unless otherwise noted) (normal mode) (see Figure 14)  
SN54ABT18646  
UNIT  
MIN  
MAX  
f
t
t
t
Clock frequency  
Pulse duration  
Setup time  
CLKAB or CLKBA  
0
100  
MHz  
ns  
clock  
CLKAB or CLKBA high or low  
A before CLKABor B before CLKBA↑  
A after CLKABor B after CLKBA↑  
5
w
6.2  
0.6  
ns  
su  
h
Hold time  
ns  
timing requirements over recommended ranges of supply voltage and operating free-air  
temperature (unless otherwise noted) (test mode) (see Figure 14)123  
SN54ABT18646  
UNIT  
MIN  
MAX  
f
t
Clock frequency  
Pulse duration  
TCK  
0
50  
MHz  
ns  
clock  
TCK high or low  
8.2  
6.4  
7.5  
3
w
A, B, CLK, DIR, OE, or S before TCK↑  
TDI before TCK↑  
t
Setup time  
Hold time  
ns  
ns  
su  
h
TMS before TCK↑  
A, B, CLK, DIR, OE, or S after TCK↑  
TDI after TCK↑  
0.7  
0.5  
0.5  
t
TMS after TCK↑  
t
t
Delay time  
Rise time  
Power up to TCK↑  
ns  
d
V
CC  
power up  
µs  
r
4–26  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
switching characteristics over recommended ranges of supply voltage and operating free-air  
temperature (unless otherwise noted) (normal mode) (see Figure 14)  
V
T
= 5 V,  
= 25°C  
CC  
A
SN54ABT18646  
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
UNIT  
MIN  
100  
2
TYP  
MAX  
MIN  
100  
1.5  
1.4  
2.1  
2.5  
1.5  
2
MAX  
f
t
t
t
t
t
t
t
t
t
t
t
t
t
t
CLKAB or CLKBA  
A or B  
130  
MHz  
ns  
max  
PLH  
PHL  
PLH  
PHL  
PLH  
PHL  
PZH  
PZL  
PZH  
PZL  
PHZ  
PLZ  
PHZ  
PLZ  
5.1  
6.3  
7.5  
7
5.8  
7.1  
8.6  
8
B or A  
B or A  
B or A  
B or A  
B or A  
B or A  
B or A  
1.7  
2.5  
2.5  
2
CLKAB or CLKBA  
SAB or SBA  
DIR  
ns  
ns  
ns  
ns  
ns  
ns  
7.1  
7.7  
7.3  
8.4  
7.9  
8.6  
9.4  
8.5  
8.9  
8.1  
8
2
8.7  
8.5  
9.6  
9.1  
9.8  
11.5  
9.4  
11  
2
1.7  
2.5  
1.8  
2.7  
3
3
2
OE  
2.7  
3.5  
3
DIR  
2.1  
3.5  
1.5  
3.5  
2
OE  
9.4  
switching characteristics over recommended ranges of supply voltage and operating free-air  
temperature (unless otherwise noted) (test mode) (see Figure 14)123  
V
T
= 5 V,  
= 25°C  
CC  
A
SN54ABT18646  
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
UNIT  
MIN  
50  
2.5  
2.5  
2
TYP  
MAX  
MIN  
50  
2.5  
2.5  
2
MAX  
f
t
t
t
t
t
t
t
t
t
t
t
t
TCK  
90  
MHz  
ns  
max  
PLH  
PHL  
PLH  
PHL  
PZH  
PZL  
PZH  
PZL  
PHZ  
PLZ  
PHZ  
PLZ  
12.3  
11.8  
5.8  
6.6  
12.1  
13.4  
7
15.3  
14.2  
7
TCK↓  
A or B  
TDO  
TCK↓  
TCK↓  
TCK↓  
TCK↓  
TCK↓  
ns  
ns  
ns  
ns  
ns  
2
2
7
4.5  
5
4.5  
5
15.3  
16.3  
7.5  
8
A or B  
TDO  
2.5  
3
1.8  
3
7.5  
15  
4
4
18  
A or B  
TDO  
3
14.5  
8.4  
7.6  
3
17.5  
9.5  
8
3
3
3
2.7  
4–27  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
SN54ABT18646  
SCAN TEST DEVICE WITH  
18-BIT TRANSCEIVERS AND REGISTERS  
SGBS306 – AUGUST 1992 – REVISED AUGUST 1994  
PARAMETER MEASUREMENT INFORMATION  
7 V  
Open  
S1  
500 Ω  
From Output  
Under Test  
TEST  
S1  
GND  
t
t
/t  
Open  
7 V  
PLH PHL  
/t  
C
= 50 pF  
L
t
500 Ω  
PLZ PZL  
/t  
(see Note A)  
Open  
PHZ PZH  
LOAD CIRCUIT FOR OUTPUTS  
3 V  
0 V  
Timing Input  
Data Input  
1.5 V  
t
w
t
t
h
su  
3 V  
0 V  
3 V  
0 V  
Input  
1.5 V  
1.5 V  
1.5 V  
1.5 V  
VOLTAGE WAVEFORMS  
PULSE DURATION  
VOLTAGE WAVEFORMS  
SETUP AND HOLD TIMES  
3 V  
0 V  
3 V  
0 V  
Input  
(see Note B)  
Output  
Control  
1.5 V  
1.5 V  
1.5 V  
1.5 V  
t
PZL  
t
t
PHL  
PLH  
t
PLZ  
Output  
Waveform 1  
S1 at 7 V  
V
V
3.5 V  
OH  
1.5 V  
1.5 V  
1.5 V  
1.5 V  
Output  
V
V
+ 0.3 V  
– 0.3 V  
OL  
V
OL  
OL  
(see Note C)  
t
PHZ  
t
PLH  
t
t
PZH  
PHL  
Output  
Waveform 2  
S1 at Open  
(see Note C)  
V
OH  
V
V
OH  
OH  
1.5 V  
1.5 V  
Output  
0 V  
OL  
VOLTAGE WAVEFORMS  
PROPAGATION DELAY TIMES  
INVERTING AND NON-INVERTING OUTPUTS  
VOLTAGE WAVEFORMS  
ENABLE AND DISABLE TIMES  
LOW- AND HIGH-LEVEL ENABLING  
NOTES: A.  
C includes probe and jig capacitance.  
L
B. All input pulses are supplied by generators having the following characteristics: PRR 10 MHz, Z = 50 , t 2.5 ns, t 2.5 ns.  
O
r
f
C. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.  
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.  
D. The outputs are measured one at a time with one transition per measurement.  
Figure 14. Load Circuit and Voltage Waveforms  
4–28  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
PACKAGE OPTION ADDENDUM  
www.ti.com  
25-Sep-2013  
PACKAGING INFORMATION  
Orderable Device  
Status Package Type Package Pins Package  
Eco Plan Lead/Ball Finish  
MSL Peak Temp  
Op Temp (°C)  
Device Marking  
Samples  
Drawing  
Qty  
(1)  
(2)  
(3)  
(4/5)  
5962-9469801QXA  
ACTIVE  
CFP  
HV  
68  
1
TBD  
Call TI  
N / A for Pkg Type  
-55 to 125  
5962-9469801QX  
A
SNJ54ABT18646H  
V
SNJ54ABT18646HV  
ACTIVE  
CFP  
HV  
68  
1
TBD  
Call TI  
N / A for Pkg Type  
-55 to 125  
5962-9469801QX  
A
SNJ54ABT18646H  
V
(1) The marketing status values are defined as follows:  
ACTIVE: Product device recommended for new designs.  
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.  
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.  
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.  
OBSOLETE: TI has discontinued the production of the device.  
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability  
information and additional product content details.  
TBD: The Pb-Free/Green conversion plan has not been defined.  
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that  
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.  
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between  
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.  
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight  
in homogeneous material)  
(3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.  
(4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.  
(5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation  
of the previous line and the two combined represent the entire Device Marking for that device.  
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information  
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and  
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.  
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.  
Addendum-Page 1  
PACKAGE OPTION ADDENDUM  
www.ti.com  
25-Sep-2013  
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.  
OTHER QUALIFIED VERSIONS OF SN54ABT18646 :  
Catalog: SN74ABT18646  
NOTE: Qualified Version Definitions:  
Catalog - TI's standard catalog product  
Addendum-Page 2  
IMPORTANT NOTICE  
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other  
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest  
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and  
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale  
supplied at the time of order acknowledgment.  
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms  
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary  
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily  
performed.  
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and  
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide  
adequate design and operating safeguards.  
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or  
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information  
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or  
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the  
third party, or a license from TI under the patents or other intellectual property of TI.  
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration  
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered  
documentation. Information of third parties may be subject to additional restrictions.  
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service  
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.  
TI is not responsible or liable for any such statements.  
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements  
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support  
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which  
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause  
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use  
of any TI components in safety-critical applications.  
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to  
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and  
requirements. Nonetheless, such components are subject to these terms.  
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties  
have executed a special agreement specifically governing such use.  
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in  
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components  
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and  
regulatory requirements in connection with such use.  
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of  
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.  
Products  
Applications  
Audio  
www.ti.com/audio  
amplifier.ti.com  
dataconverter.ti.com  
www.dlp.com  
Automotive and Transportation www.ti.com/automotive  
Communications and Telecom www.ti.com/communications  
Amplifiers  
Data Converters  
DLP® Products  
DSP  
Computers and Peripherals  
Consumer Electronics  
Energy and Lighting  
Industrial  
www.ti.com/computers  
www.ti.com/consumer-apps  
www.ti.com/energy  
dsp.ti.com  
Clocks and Timers  
Interface  
www.ti.com/clocks  
interface.ti.com  
logic.ti.com  
www.ti.com/industrial  
www.ti.com/medical  
Medical  
Logic  
Security  
www.ti.com/security  
Power Mgmt  
Microcontrollers  
RFID  
power.ti.com  
Space, Avionics and Defense  
Video and Imaging  
www.ti.com/space-avionics-defense  
www.ti.com/video  
microcontroller.ti.com  
www.ti-rfid.com  
www.ti.com/omap  
OMAP Applications Processors  
Wireless Connectivity  
TI E2E Community  
e2e.ti.com  
www.ti.com/wirelessconnectivity  
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265  
Copyright © 2013, Texas Instruments Incorporated  

相关型号:

SNJ54ABT18652AHV

ABT SERIES, DUAL 9-BIT BOUNDARY SCAN REG TRANSCEIVER, TRUE OUTPUT, CQFP68
TI

SNJ54ABT2240AFK

具有 TTL 兼容型 CMOS 输入和三态输出的军用 8 通道 4.5V 至 5.5V 反相器 | FK | 20 | -55 to 125
TI

SNJ54ABT2240AJ

具有 TTL 兼容型 CMOS 输入和三态输出的军用 8 通道 4.5V 至 5.5V 反相器 | J | 20 | -55 to 125
TI

SNJ54ABT2240AW

OCTAL BUFFERS AND LINE/MOS DRIVERS WITH 3-STATE OUTPUTS 20-CFP -55 to 125
TI

SNJ54ABT2244W

ABT SERIES, DUAL 4-BIT DRIVER, TRUE OUTPUT, CDFP20, CERAMIC, DFP-20
ROCHESTER

SNJ54ABT2245FK

具有三态输出的八路收发器和线路/MOS 驱动器 | FK | 20 | -55 to 125
TI

SNJ54ABT2245J

具有三态输出的八路收发器和线路/MOS 驱动器 | J | 20 | -55 to 125
TI

SNJ54ABT2245W

具有三态输出的八路收发器和线路/MOS 驱动器 | W | 20 | -55 to 125
TI

SNJ54ABT240FK

OCTAL BUFFERS/DRIVERS WITH 3-STATE OUTPUTS
TI

SNJ54ABT240J

OCTAL BUFFERS/DRIVERS WITH 3-STATE OUTPUTS
TI

SNJ54ABT240W

OCTAL BUFFERS/DRIVERS WITH 3-STATE OUTPUTS
TI

SNJ54ABT241AJ

ABT SERIES, DUAL 4-BIT DRIVER, TRUE OUTPUT, CDIP20
TI