TP01AZ220S15W [TOPPOWER]
1W, 2W 3KVAC Isolation Wide Input AC/DC Converters;型号: | TP01AZ220S15W |
厂家: | 南京拓品微 |
描述: | 1W, 2W 3KVAC Isolation Wide Input AC/DC Converters |
文件: | 总3页 (文件大小:261K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TP01(02)AZ Series
1W, 2W 3KVAC Isolation Wide Input AC/DC Converters
DESCRIPTION
:
The rated output power of TP01(02)AZ series is 1W,2W with wide input voltage range, for both AC input and
DC input application High reliability, Low power consumption, low leakage current 0.1mA, High
isolation Product safe and reliable,Good EMC performance,EMC And meet the safety specifications of
IEC/EN61000-4 CISPR22/EN55022 UL62368/EN662368/IEC62368 Widely used in industrial control and
.
.
、
、
.
electrical instrumentation, smart home, which do not have high requirement on EMC.
The EMC external circuit must be added if the products need to be applied to EMC harsh environment.
FEATURES
Low Ripple & Noise
、
Output protection
ultra-small size
,width is only1.5CM , plastic case
Universal input voltage range
Built-in EMI filter circuit
Lower power consumption, no-load loss<0.05W
RoHS compliant
SELECTION GUIDE
Efficiency
(Typ. )
Input Voltage
Output
Part Number
Ripple (mv)
VAC
VDC
Voltage(VDC)
Current(mA)
%
300
62
150
150
150
150
150
150
150
150
150
150
150
150
TP01AZ220S03W
TP01AZ220S05W
TP01AZ220S09W
TP01AZ220S12W
TP01AZ220S15W
TP01AZ220S24W
TP02AZ220S03W
TP02AZ220S05W
TP02AZ220S09W
TP02AZ220S12W
TP02AZ220S15W
TP02AZ220S24W
85-305
85-305
85-305
85-305
85-305
85-305
85-305
85-305
85-305
85-305
85-305
85-305
80-400
80-400
80-400
80-400
80-400
80-400
80-400
80-400
80-400
80-400
80-400
80-400
3.3
200
111
83
68
70
71
71
74
64
70
73
75
75
77
5
9
12
15
24
3.3
5
67
42
600
400
222
167
133
83
9
12
15
24
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
INPUT CHARACTERISTICS
Voltage range
85~ 305VAC,80 ~ 400VDC
47 ~ 440Hz
Input frequency
Input current (Typ.)
55m A / 115VAC,34m A / 230VAC
20 A/230 VAC
Inrush Current (Typ.)
Recommended values for External Fuses
Leakage current ( Typ.)
10Ω/1W( Fusible Resistor)
<0.1Ma at 265VAC/50Hz
OUTPUT CHARACTERISTICS
Output Voltage accuracy
Line regulation
±3.0% (±5.0% max
)
±1.0%
Load regulation
±1.0%
Start rising time( Typ.)
Start holding time( Typ.)
Short circuit protection
20ms/230VAC
40ms/230VAC
50ms/115VAC at full load
15ms/115VAC at full load
Over-Load protection , Over-Current protection ,Short circuit protection , Auto recovery
GENERAL CHARACTERISTICS
Operating temperature
Operating humidity
—
40 ~ +80
85% .RH max
40 ~ +85, 10 ~ 95% RH
0.03%/ (0~ 50
10~500Hz,2G10min./1cycle, 60min.each along X,Y,Z axes
℃ (≧50℃, derating @0.011W/℃)
Storage temperature
Temperature coefficient
Vibration coefficient
–
℃
)
www.gztoppower.com
TEL:0086-20-62162688
Email:sales2@gztoppower.com
Page1 / 3
TP01(02)AZ Series
SAFETY AND ELECTROMAGNETIC COMPATIBILITY
Safety standard
EN60950,EN60601,UL60950
Isolated Voltage
I/P-O/P:3000VAC
Isolated resistance
I/P-O/P>100M Ohms/500VDC 25
℃
70% RH
Conduction and radiation
Electrostatic discharge ( ESD)
Radiofrequency radiation immunity(RF)
Electrical fast transient(EFT)
Surge
EN55011, EN55022 (CISPR22) CLASS B
IEC/EN 61000-4-2 level 4 8kV/15kV See the application note for details
IEC/EN 61000-4-3 See the application note for details
(See the application note for details)
(
)
(
)
IEC/EN 61000-4-4 level 4 4kV
IEC/EN 61000-4-5 level 4 2kV
OTHER CHARACTERISTICS
200K hrs min.
32*20*15mm
MIL-HDBK-217F(25)
MTBF
Dimension
NOTES
1.The above data except for special instructions, are measured at TA = 25oC, humidity <75%, input nominal voltage 230Vac and output rated load
2.Ripple & noise are measured in accordance with the link of the application circuit in this manual, using a 300mm twisted pair-wire and 20MHZ bandwidth
3.The power supply is considered a component which will be installed into a final equipment.
The final equipment must be re-confirmed that it still meets EMC directives
TYPICAL APPLICATION CIRCUIT
Notes:
1.The output filter capacitor C5 is electrolytic capacitor, recommend using of high frequency and low resistance of electrolytic capacitors, the capacity and the current
flowing-through need refer to the technical specifications provided by the manufacturer. C4 is use to remove high frequency noise.
2.EMC filter used in the dashed box is to meet the higher requirements,if it is used in general applications,it can be omitted.
3. Our company make the filter circuit in the dashed box which can be used with switching power supply
,
www.gztoppower.com
TEL:0086-20-62162688
Email:sales2@gztoppower.com
Page2 / 3
TP01(02)AZ Series
MECHANICAL DIMENSIONS
PIN CONNECTIONS
DIP packaging
Pin
1
Single Output
L
2
N
3
+Vo
-V0
4
Units:mm
Tolerance:±0.2mm
SELECTION GUIDE
TP 02
A
Z 220 S 05
W
W:4:1 Wide voltage input range
Main (auxiliary) output voltage
S:single output
Rated input voltage
Package type
AC-DC
Rated output power
Brand name
RATING GR
www.gztoppower.com
TEL:0086-20-62162688
Email:sales2@gztoppower.com
Page3 / 3
相关型号:
TP0202K-E3
TRANSISTOR 385 mA, 30 V, P-CHANNEL, Si, SMALL SIGNAL, MOSFET, TO-236, TO-236, 3 PIN, FET General Purpose Small Signal
VISHAY
©2020 ICPDF网 联系我们和版权申明