TBLC90-124 [TRACOPOWER]
Industrial Power Supplies;型号: | TBLC90-124 |
厂家: | TRACO ELECTRONIC AG |
描述: | Industrial Power Supplies |
文件: | 总5页 (文件大小:535K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Industrial Power Supplies
TBLC Series, 6 – 90 W
• Low profile case, module depth only 55 mm
• Suitable for mounting in domestic
installation panels
• Very high efficiency and low standby
power - compliance to ECOꢀStandard
• High power density
• Low output ripples and spikes
• Suitable for household appliance and
industrial applications
• For distributed power
• UL 1310 class II, NEC class 2 compliance
• UL 508 listed
• Universal input range 85 to 264 VAC
CB
• Operating temperature range:
Scheme
UL508
UL60950-1
–25°C to +70°C
This new DIN-Rail mounting power supplies are designed for industrial and resi-
dential applications. They are lower cost than the existing TBL range, with similar
electrical specifications. Additionally, they fully comply to the new standby power
and efficiency requirements (ECO Standard). They are intended for connect-
ing as class II devices, so the safety earth connection is not required. They are
mountable in flat racks due to their small dimensions in depth. Their dimensions
comply to the DIN 43880 standard.
• Adjustable output voltage
• Short circuit and overload protection
• DC–OK indicator LED
Models
Order Code
Output Power
Output Voltage*
Output Current
Efficiency
(max.)
(nom.)(adjustable)
(max.)
(typ.)
TBLC 06-105
TBLC 06-112
TBLC 06-124
TBLC 15-105
TBLC 15-112
TBLC 15-124
TBLC 25-105
TBLC 25-112
TBLC 25-124
TBLC 50-112
TBLC 50-124
TBLC 75-112
TBLC 75-124
TBLC 90-112
TBLC 90-124
6 W
6 W
5.0 VDC
12 VDC
24 VDC
5.0 VDC
12 VDC
24 VDC
5.0 VDC
12 VDC
24 VDC
12 VDC
24 VDC
12 VDC
24 VDC
12 VDC
24 VDC
1.2 A
0.5 A
0.25 A
2.4 A
1.25 A
0.63 A
4.0 A
2.0 A
1.05 A
4.0 A
2.1 A
6.0 A
3.1 A
7.5 A
3.75 A
74 %
81 %
79 %
81 %
85 %
85 %
82 %
86 %
87 %
88 %
89 %
89 %
89 %
90 %
90 %
6 W
12 W
15 W
15 W
20 W
24 W
25 W
48 W
50 W
72 W
75 W
90 W
90 W
http://www.tracopower.com
Page 1 of 5
TBLC Series, 6 – 90 W
Input Specifications
Input voltage
– nominal ranges
– effective ranges
100 – 240 VAC; 50/60 Hz
85 – 264 VAC; 47-63 Hz
(below 100 VAC a derating of 2 %/V is required)
Input voltage frequency
47 – 63 Hz
No load power consumption
6–50 W models: < 0.3 W
75–90 W models: < 0.5 W
Harmonic limits
Leakage current
Inrush current
EN 61000-3-2, class A
0.25 mA max.
6–50 W models: 15/30 A (115/230 VAC)
75–90 W models: 25/50 A (115/230 VAC)
Output Specifications
Output voltage / current
5 VDC models: 5.0 – 5.5 VDC*
12 VDC models: 12.0 – 16.0 VDC*
24 VDC models: 24.0 – 28.0 VDC*
Regulation
Hold-up time
Start-up
– Input variation
– Load variation (10–90 %)
0.3 % max.
0.3 % max.
60 ms min. (at 230 VAC)
15 ms typ. (at 115 VAC)
– Start up behavior
– Start up time
TBLC 75-112 and 90-112: 0-75 % constant current load
other models: 0-100 % constant current load
1 s max.
Ripple and Noise (20 MHz bandwidth)
Current limit (continuous)
Short circuit current
50 mVp-p max.
105 – 130 % of Iout nom., constant current
TBLC 75-112 and 90-112: 70 – 90 % of Iout nom. (typ.), foldback
other models: 120 – 200 % of I out nom
Output overvoltage protection
150 % of Vout nom. (typ.)
> 95 % of the set voltage
DC OK signal
– trigger threshold ON
General Specifications
Operating temperature
–25°C to +70°C
derating above +55ºC: 2.5 %/K
Storage temperature
Temperature coefficient
Cooling
–40°C to +85°C
0.02 %/K
convection cooling, no internal fan
2
Pollution degree
Humidity (non condensing)
Altitude during operation
5–95 % rel. H max.
4800 m max.
Isolation
– I/O isolation
3000 VAC (4242 VDC)
safety class II
Class of protection
Degree of protection
IP 20 (IEC/EN 60529)
> 1.9 Mio. h
Reliability, calculated MTBF (at 25°C acc. to IEC 61709)
* Output voltage can be adjusted as indicated. However, output power has to be maintained at nominal value.This means the output
nominal current has to be reduced in accordance with the increase of output voltage.
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 5
TBLC Series, 6 – 90 W
General Specifications (continued)
Safety standards
– Information technology equipment
IEC/EN 60950-1, UL 60950-1
– Household applications
IEC/EN 60335-1
– Safety of machinery
EN 60204
– Safety for power electronic converter systems
– Industrial control equipment
– Class II Power units
IEC/EN 62477
UL 508
UL 1310
– NEC class 2
– Electronic equipment for power installation
– Safety of transformers
UL 1310 (not TBLC 90-xxx and TBLC 75-112)
EN 50178
EN 61558-2-8, EN 61558-2-16
www.tracopower.com/overview/tblc
– Certification documents
Electromagnetic compatibility (EMC), Emissions
– Conducted RI suppression on input
EN 61000-6-3, EN 61204-3
EN 55032 class B
– Conducted disturbance on output TBLC 50/75/90: EN 55014 class B, CISPR 16-1-1
– Radiated RI suppression
EN 55032 class B
– Harmonic current emissions
IEC 61000-3-2 class A
Electromagnetic compatibility (EMC), Immunity
EN 61000-6-2, EN 61204-3
– Electrostatic discharge (ESD)
– Radiated RF field immunity
– Electrical fast transient / burst immunity
– Surge immunity
IEC/EN 61000-4-2 4 kV/8 kV criteria B
IEC/EN 61000-4-3 10 V/m
IEC/EN 61000-4-4 2 kV
criteria A
criteria B
IEC/EN 61000-4-5 1 kV/2 kV criteria B
– Immunity to conducted RF disturbances
– Power frequency field immunity
– Mains voltage dips and interruptions
IEC/EN 61000-4-6 10 V
IEC/EN 61000-4-8 30 A/m
IEC/EN 61000-4-11
0% / 20 ms
criteria A
criteria A
40% / 200 ms
70% / 500 ms
Environment
– Vibration acc. IEC 60068-2-6
– Shock acc. IEC 60068-2-27
3 axis, 2 g sine sweep, 10 – 150 Hz, 90 min
3 axis, 30 g half sine, 11 ms
Enclosure material
Mounting
V2 rated plastic
– DIN-rail mounting
for DIN-rails as per EN 50022 – 35ꢀ15/7.5
(snap-on with self-locking spring) (included)
Environmental compliance – Reach
www.tracopower.com/products/reach-declaration.pdf
RoHS directive 2011/65/EU
– RoHS
Connection
screw terminal with combi-type screw heads
for wire size 0.5 – 2.5 mm2
http://www.tracopower.com
Page 3 of 5
TBLC Series, 6 – 90 W
Function Specification
Block Diagram
Current Limit Characteristic
nominal (100%)
Vout
other models
TBLC 75-112/90-112
short = 70 - 90 % of I nominal
I
short = 120 - 200% of I nominal
I
70% 90%
120%
200% Iout
The load characteristic is designed to accomplish reliable start-up of heavy loads.
Note: All 6 Watt models (TBLC 06-xxx) implement a pulsing power characteristic when in overload or short circuit conditions.
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 4 of 5
TBLC Series, 6 – 90 W
Outline Dimensions
59.5 mm
DIN 43880 Size 1
Weigth
[g]
Model
Width A
18 mm
27 mm
36 mm
54 mm
72 mm
90 mm
TBLC 06
TBLC 15
TBLC 25
TBLC 50
TBLC 75
TBLC 90
60
80
110
180
220
280
43.5 mm
54.5 mm
A
Tolerances: 0.5 mm
Wall Mounting Bracket
Instead of on a DIN-rail, the modules can also be mounted on a chassis or wall with help of a
mounting bracket which is supplied as standard with each power supply.
Wiring
Description
Wire size
Torque
0.5 Nm
0.5 Nm
0.5 Nm
AC Input
all models: L, N only (2 pin terminal)
6 – 50 W models: single terminal
75 – 90 W models: double terminal
AWG 20 – 14 / 0.5 – 2.5 mm² max.
AWG 20 – 14 / 0.5 – 2.5 mm² max.
AWG 20 – 14 / 0.5 – 2.5 mm² max.
DC Output
DC Output
©
Copyright 2017 Traco Electronic AG
Specifications can be changed without notice!
Rev. December 6, 2017
www.tracopower.com
Page 5 of 5