TMSB2-285 [TRACOPOWER]

AC/DC Power Modules;
TMSB2-285
型号: TMSB2-285
厂家: TRACO ELECTRONIC AG    TRACO ELECTRONIC AG
描述:

AC/DC Power Modules

文件: 总4页 (文件大小:288K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
AC/DC Power Modules  
TMSB 2 Series, 2 Watt  
CB  
Scheme  
LVD  
UL 60950-1  
Features  
Standby power module to comply  
with ErP directive  
No load input power < 30mW  
Constant power characteristics at 2W  
(no current limitation)  
Suitable to drive relays, selenoids,  
capacitive loads and LED’s  
Constant voltage auxiliary outputs  
3.3 and 5 VDC  
Operating temperature range  
–30°C to +70°C  
EMI meets EN 55022, class B and  
FCC, level B  
Short circuit and overload protection  
3-year product warranty  
The TMSB-2 series are compact AC/DC power supplies in a fully encapsulated  
plastic casing with solder pins for direct PCB mounting. They feature regulated  
outputs and constant power characteristics which make them suitable to drive relays,  
solenoids, LED’s and capacitive loads. Models with an additional regulated  
auxiliary output can be used to power a logic circuit in standby functions.  
An universal input voltage 85–264 VAC, safety approvals including approvals for  
household applications (EN 60335-1) and an operating temp. range from –30°C to  
+70°C qualify them for worldwide markets.  
Models  
Order code  
Output power max.  
Output 1  
Output 2  
Efficiency  
72 %  
TMSB 2-108  
TMSB 2-114  
TMSB 2-124  
TMSB 2-283  
TMSB 2-285  
TMSB 2-2143  
TMSB 2-2145  
8.0 VDC / 250 mA  
14 VDC / 143 mA  
24 VDC / 83 mA  
8.0 VDC / 250 mA 1)  
8.0 VDC / 250 mA 1)  
14 VDC / 143 mA 2)  
14 VDC / 143mA 2)  
74 %  
76 %  
3.3 VDC / 160 mA 1)  
5.0 VDC / 250 mA 1)  
3.3 VDC / 70 mA 2)  
5.0 VDC / 83 mA 2)  
69 %  
2 W  
69 %  
70 %  
70 %  
1) Total output current must not exceed 250 mA  
2) Total output current must not exceed 143 mA  
http://www.tracopower.com  
Page 1 of 4  
AC/DC Power Modules  
TMSB 2 Series  
2 Watt  
Input Specifications  
Input voltage ranges  
– AC input  
– DC Input  
85 – 264 VAC  
120 – 370 VDC  
Input frequency  
47 – 440 Hz  
41 mA typ.  
30 mW typ.  
Input current at full load (115 VAC / 230 VAC nominal input)  
No-Load power consumption  
External fuse (required)  
3.15 A slow blow type (recommendation)  
Input sugre voltage  
305 VAC max.  
Output Specifications  
Voltage set accuracy  
Output 1:  
Output 2:  
5 % max.  
2 % max.  
Minimum load  
no minimum load required  
Ripple and noise (20 MHz bandwidth)  
Output 1: 1 % of Vout [Vp-p] typ.  
Output 2: 0.1 % of Vout [Vp-p] typ.  
Regulation – Input variation  
Regulation – Load variation  
Output 1: 1 %  
Output 2: 0.3 %  
Output 1: 1 %  
Output 2: 0.5 %  
Short circuit protection  
continuous  
General Specifications  
Temperature ranges  
– Operating  
– Power derating above +60°C  
– Storage (non operating)  
–30°C to +70°C  
xxx models: 2.0 %/K  
–40°C to +85°C  
Temperature coefficient  
0.02 %/°C  
Humidity (non condensing)  
95 % rel max.  
45 kHz typ.  
3‘000 VAC  
>500’000 h  
Switching frequency (pulse width modulation PWM)  
Isolation voltage – Input/Output  
Reliability /calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign)  
Electromagnetic compatibility  
(EMC), emissions  
– Conducted input RI suppression EN 55022, class B, FCC part 15, level B  
– Radiated input surpression EN 55014-1  
Electromagnets compatibility – Electrostatic discharge ESD  
IEC / EN 61000-4-2, criteria A  
IEC / EN 61000-4-3, criteria A  
IEC / EN 61000-4-4, criteria A  
IEC / EN 61000-4-5, criteria A  
IEC / EN 61000-4-6, criteria A  
IEC / EN 61000-4-11  
(EMC), immunity  
– RF field immunity  
– Electrical fast transients/burst immunity  
– Surge  
– Conducted RF  
– Voltage dip  
Protection class II  
Safety standards  
Acording IEC/EN 60536  
IEC/EN 60950-1 (ed. 2) AM 1, UL 60950-1,  
CSA C22.2 No. 60950-1-07  
EN 60335-1:2010  
– Certification documents  
www.tracopower.com/overview/tmsb2  
Casing material  
plastic resin + fiberglass (UL 94V-0 rated)  
Environmental compliance – Reach  
www.tracopower.com/overview/tmsb2  
RoHS directive 2011/65/EU  
– RoHS  
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.  
http://www.tracopower.com  
Page 2 of 4  
AC/DC Power Modules  
TMSB 2 Series  
2 Watt  
Output characteristics  
Single output models:  
(e.g. TMSB 2-108)  
constant power area  
constant voltage  
10  
8
6
4
2
0
0 100  
200  
300  
400  
500  
600  
700  
800  
900  
Output Current (mA)  
Dual output models:  
(e.g. TMSB 2-285)  
constant voltage (cv)  
constant power (cp)  
8
150mA  
200mA  
250mA  
constant load on Vr  
5.3 VDC  
100mA  
50mA  
No load  
Area where Vr equals  
Vo-0.3V  
0
800  
Output current (mA)  
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.  
http://www.tracopower.com  
Page 3 of 4  
AC/DC Power Modules  
TMSB 2 Series  
2 Watt  
Outline Dimensions  
TMSB 2:  
Pinout / Conecction  
2
3
4
5
Pin/con.  
Single  
Dual  
1
2
3
4
5
6
7
NC  
NC  
Bottom view  
NC  
NC  
+Vout  
–Vout  
No Pin  
AC(N)  
AC(L)  
+Vout1  
Common  
+Vout2  
AC(N)  
AC(L)  
6
7
1
14.8 (0.58)  
3.2  
(0.13)  
3.7  
(0.15)  
21.00 (0.83)  
28.4 (1.12)  
NC = not to connect  
Dimensions in[mm], () = Inches  
Tolerances = 0.5mm (0.02)  
Weight: 24 g (0.85 oz)  
Pin diameter ø 0.8 mm (0.03 0.004)  
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com  
Rev. October 26. 2015  
www.tracopower.com  
Page 4 of 4  
http://www.tracopower.com  

相关型号:

TMSB2_18

AC/DC Power Modules

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TRACOPOWER

TMSC6701

FLOATING POINT DIGITAL SIGNAL PROCESSOR

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TI

TMSC6701GJC16719V

FLOATING POINT DIGITAL SIGNAL PROCESSOR

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TI

TMSC6727BZDH300TAN

Floating-Point Digital Signal Processor 256-BGA

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TI

TMSC6727BZDH350TAN

Floating-Point Digital Signal Processor 256-BGA

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TI

TMSDC6722BRFPA225

Floating-Point Digital Signal Processors

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TI

TMSDC6726BRFPA225

Floating-Point Digital Signal Processors

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TI

TMSDC6727BGDHA250

Floating-Point Digital Signal Processors

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TI

TMSDC6727BZDHA250

Floating-Point Digital Signal Processors

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TI

TMSDM6446AZWT-COM

达芬奇数字媒体片上系统 | ZWT | 361 | 0 to 85

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TI

TMSDM6467CCUT7TAN

数字媒体片上系统 | CUT | 529 | 0 to 85

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TI

TMSDVC5402PGE100G4

数字信号处理器 | PGE | 144 | 0 to 0

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
TI