TFS 112H - 1/5  
1. Measurement condition :  
Ambient temperature TA:  
23 °C  
Input power level:  
Terminating impedances at f :  
0 dBm.  
for input:  
for output:  
50...70  
565 - 6,5 pF.  
650 - 5,7 pF.  
c
Q-value of matching elements:  
2. Characteristics :  
Remark:  
Reference level for the relative attenuation a of the TFS 112H is the minimum of the passband attenuation a  
. The minimum of the passband  
min  
rel  
attenuation a  
min  
is defined as the insertion loss a . The reference frequency  
f
c
is the arithmetic mean value of the upper and lower  
e
frequencies at the 30 dB filter attenuation level relative to the insertion loss a .  
e
D a t a  
typ. value  
13,5 dB  
tolerance / limit  
max. 14 dB  
112,320 ± 0,035 MHz  
Insertion loss (Reference level) a  
e
Reference frequency  
Bandwidth at ambient temperature:  
dB bandwidth  
f
( BW(-30 dB) )  
112,32 MHz  
c
3
1,05 MHz  
1,72 MHz  
min.  
min.  
0,95 MHz  
1,63 MHz  
10 dB bandwidth  
20 dB bandwidth  
30 dB bandwidth  
40 dB bandwidth  
2,17 MHz  
2,45 MHz  
2,66 MHz  
max.  
max.  
max.  
2,35 MHz  
2,60 MHz  
2,95 MHz  
Relative attenuation  
a
rel  
f
.........  
f
±
±
0,475 MHz  
0,815 MHz  
-
-
max.  
max.  
3
10  
dB  
dB  
c
c
c
f
±
0,475 MHz ... f  
c
f
f
f
f
f
f
f
±
±
±
+
+
1,175 MHz ... f  
1,300 MHz ... f  
1,475 MHz ... f  
±
±
±
+
1,300 MHz  
1,475 MHz  
-
-
min.  
min.  
min.  
min.  
min.  
min.  
min.  
20  
30  
40  
22  
25  
35  
35  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
c
c
c
c
c
c
c
c
c
c
c
c
c
5,0  
7,5  
MHz  
MHz  
> 45  
26  
> 32  
> 40  
42...45  
dB  
dB  
dB  
dB  
dB  
5,0  
MHz ... f  
7,5  
MHz ... f + 17,28 MHz  
+ 17,28 MHz ... f + 20  
- 20  
MHz  
MHz  
MHz ... f  
-
5
c
Average group delay in  
Group delay ripple in  
f
....f ± 800 kHz :  
1,35 µs  
c
c
f
....f ± 800 kHz :  
150  
ns  
max. 300  
ns  
c
c
Frequency inversion temperature ( To )  
Temperature coefficient ( Tc1f ) 1st order *)  
Temperature coefficient ( Tc2f ) 2nd order **)  
20  
0
°C  
ppm/K  
max. ± 7,5  
-
ppm/K  
- 0,036 ppm/K²  
Operating temperature range  
Storage temperature range  
- 20 °C ... + 85 °C  
- 25 °C ... + 90 °C  
Input power level  
Permissible DC voltage  
Permissible AC voltage  
-
-
-
max.  
10  
12  
10  
dBm  
V
V
V
V
DC  
pp  
* )  
** )  
f (Hz) = Tc1f(ppm/K) x (T - To) x fTo (MHz)  
c
f (Hz) = Tc2f(ppm/K) x (T - To)² x fTo (MHz)  
c
fTo is reference frequency f at frequency inversion temperature (To )  
c
Generated:  
Dunzow W.  
Checked/Approved:  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
e-mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
e-mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as  
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs112H.doc  
Version 1.3  
14.02.2001  
VI TELEFILTER  
Filter Specification  
TFS 112H - 2/5  
3. Package and pin connection : (All dimensions in mm)  
TFS 112H  
tft N3  
6,4 ±0,2  
1
Datecode:  
L
Year+month  
1999  
13,20 ±0,20  
M
2000  
N
2001  
.......  
.........  
3,0 Max.  
10,16  
5,08  
1
2
3
4
7
5
1 - Balanced input  
2 - Balanced input  
3 - Package Ground.  
5 - Balanced output  
4 - Balanced output  
6
3
7, 8, 9 - Not Connected Ground.  
10  
9
8
6
12,0  
4. 50 - matching network ( Principal scheme ) :  
10  
9
8
7
6
TFS 112H  
tft N3  
L4  
L1  
L2  
C1  
C2  
50  
50  
1
2
3
4
5
L3  
10  
9
8
7
6
TFS 112H  
tft N3  
C4  
C1  
50  
L1  
L2  
50  
1
2
3
4
5
C3  
C2  
About matching element values and unbalanced Scheme see Application Note.  
VI TELEFILTER  
Vectron International, Inc.  
Potsdamer Straße 18  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
e-mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
e-mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as  
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs112H.doc  
Version 1.3  
14.02.2001  
VI TELEFILTER  
Filter Specification  
TFS 112H - 3/5  
5. Stability Characteristics :  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Resistance to  
solder heat (reflow):  
max. 2 times reflow process;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
6. Packing :  
Tape & Reel:  
DIN IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
Trailer  
1700  
min 300 mm  
min 500 mm  
min 300 mm  
EMBOSSED CARRIER TAPE  
Tape (all dimensions in mm)  
P o  
P
D
2
o
W
Po  
Do  
E
:
:
:
:
:
:
:
:
:
:
:
:
24 ± 0,3  
± 0,1  
1,5 + 0,1  
1,75 ± 0,1  
7,5 ± 0,1  
0,6  
4
E
A
o
F
F
D
1
G (min)  
P2  
P1  
D1(min)  
Ao  
Bo  
W
B
o
2
± 0,1  
12 ± 0,1  
1,5  
7,1 ± 0,2  
13,9 ± 0,2  
21,5 ± 0,1  
G
P 1  
CT  
COVER TAPE  
W
2
Reel (all dimensions in  
mm):  
A
: 330  
W1  
: 32,4 +2  
C
A
W2 (max) : 38,4  
N (min) : 100  
C
N
: 13 +0,5/-0,2  
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on  
the right side of the tape.  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
e-mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
e-mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as  
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs112H.doc  
Version 1.3  
14.02.2001  
VI TELEFILTER  
Filter Specification  
TFS 112H - 4/5  
7. Air reflow temperature conditions :  
1st and 2nd air reflow profile  
Name:  
Temperature:  
Time:  
pre-heating periods main-heating periods  
peak temperature  
255 °C ± 5 °C  
150 °C - 170 °C  
60 sec. - 90 sec.  
over 200 °C  
20 sec. - 25 sec.  
Air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
110  
120  
130  
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
23  
34  
46  
60  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Vectron International, Inc.  
267 Lowell Road  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
e-mail: tft@telefilter.com  
Tel: (603) 598-0070 Fax: (603) 598-0075  
e-mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as  
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs112H.doc  
Version 1.3  
14.02.2001  
VI TELEFILTER  
Filter Specification  
TFS 112H - 5/5  
History  
Version  
1.0  
Reason of Changes  
Name  
Date  
Generate filter specification according to customer requirements.  
Delete unbalanced matching networks.  
Dunzow W.  
Dunzow W  
Dunzow W  
16.10.2000  
19.10.2000  
17.11.2000  
1.1  
1.2  
Edit termination impedances .  
Change limit lines in selection :  
in  
in  
in  
f
f
f
+ 5,0 MHz...f + 7,50 MHz from min. 27 dB to min. 22 dB,  
+ 7,5 MHz....f + 17,28 MHz from min. 30 dB to min. 25 dB,  
c
+ 17,28 MHz ..... from min. 40 dB to min. 35 dB.  
c
c
c
c
1.3  
Format correction.  
Dunzow W.  
14.02.2001  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
e-mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
e-mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as  
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS112K

Filter Specification
VECTRON

TFS112R

Filter specification
VECTRON

TFS1150A

Development specification
VECTRON

TFS115A

Filter specification
VECTRON

TFS115C

Filter specification
VECTRON

TFS115D

Filter specification
VECTRON

TFS115E

Filter specification
VECTRON

TFS116

Filter Specification
VECTRON

TFS117

Filter specification
VECTRON

TFS1176

Filter specification
VECTRON

TFS117A

Filter Specification
VECTRON

TFS119

Filter Specification
VECTRON